CMOP ERDDAP
Columbia River observations and predictions |
| Grid DAP Data | Sub- set | Table DAP Data | Make A Graph | W M S | Source Data Files | Title | Sum- mary | FGDC, ISO, Metadata | Back- ground Info | RSS | E | Institution | Dataset ID | ||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| set | data | graph | files | Oceanographic data collected from Saturn Estuary Station 03 by Center for Coastal Margin Observation and Prediction (CMOP) and assembled by Northwest Association of Networked Ocean Observation Systems (NANOOS) in the Columbia River Estuary and North East Pacific Ocean |
| F I M | background
|
|
|
| saturn03_240_A_Fluorometer |
| Row Type | Variable Name | Attribute Name | Data Type | Value |
|---|---|---|---|---|
| attribute | NC_GLOBAL | acknowledgement | String | This deployment supported by NSF through the Science and Technology Center for Coastal Margin Observation and Prediction (STC-CMOP) and by NOAA through the Northwest Association of Networked Ocean Observing Systems (NANOOS) |
| attribute | NC_GLOBAL | cdm_data_type | String | TimeSeries |
| attribute | NC_GLOBAL | cdm_timeseries_variables | String | timeSeries, latitude, longitude |
| attribute | NC_GLOBAL | comment | String | A fixed station operated by the Science and Technology Center for Coastal Margin Observation and Prediction, Institute of Environmental Health, Oregon Health & Science University |
| attribute | NC_GLOBAL | contributor_name | String | Antonio Baptista, Michael Wilkin, Charles Seaton, Sarah Riseman |
| attribute | NC_GLOBAL | contributor_role | String | Principal Investigator, Field Program Manager, Data Manager, Quality Assessment |
| attribute | NC_GLOBAL | Conventions | String | CF-1.6, ACDD-1.3, COARDS |
| attribute | NC_GLOBAL | creator_email | String | seatonc at ohsu.edu |
| attribute | NC_GLOBAL | creator_institution | String | Oregon Health & Science University; Center for Coastal Margin Observation & Prediction |
| attribute | NC_GLOBAL | creator_name | String | Charles Seaton |
| attribute | NC_GLOBAL | creator_type | String | person |
| attribute | NC_GLOBAL | creator_url | String | http://www.stccmop.org/![]() |
| attribute | NC_GLOBAL | date_created | String | 2026-05-05T11:54:23Z |
| attribute | NC_GLOBAL | date_issued | String | 2026-05-05T11:54:23Z |
| attribute | NC_GLOBAL | date_metadata_modified | String | 2026-05-05T11:54:23Z |
| attribute | NC_GLOBAL | date_modified | String | 2026-05-05T11:54:23Z |
| attribute | NC_GLOBAL | Easternmost_Easting | double | -123.94001 |
| attribute | NC_GLOBAL | featureType | String | TimeSeries |
| attribute | NC_GLOBAL | geospatial_bounds | String | POINT(-123.94001 46.19973) |
| attribute | NC_GLOBAL | geospatial_bounds_crs | String | EPSG:4326 |
| attribute | NC_GLOBAL | geospatial_bounds_vertical_crs | String | EPSG::6359 |
| attribute | NC_GLOBAL | geospatial_lat_max | double | 46.19973 |
| attribute | NC_GLOBAL | geospatial_lat_min | double | 46.19973 |
| attribute | NC_GLOBAL | geospatial_lat_units | String | degrees_north |
| attribute | NC_GLOBAL | geospatial_lon_max | double | -123.94001 |
| attribute | NC_GLOBAL | geospatial_lon_min | double | -123.94001 |
| attribute | NC_GLOBAL | geospatial_lon_units | String | degrees_east |
| attribute | NC_GLOBAL | geospatial_vertical_positive | String | down |
| attribute | NC_GLOBAL | geospatial_vertical_units | String | cm |
| attribute | NC_GLOBAL | grid_mapping_epsg_code | String | EPSG:4326 |
| attribute | NC_GLOBAL | grid_mapping_inverse_flattening | double | 298.257223563 |
| attribute | NC_GLOBAL | grid_mapping_name | String | latitude_longitude |
| attribute | NC_GLOBAL | grid_mapping_semi_major_axis | double | 6378137.0 |
| attribute | NC_GLOBAL | history | String | File generated from CMOP postgres database using program exportDeployment.py |
| attribute | NC_GLOBAL | id | String | 4099 |
| attribute | NC_GLOBAL | infoUrl | String | http://www.stccmop.org/![]() |
| attribute | NC_GLOBAL | institution | String | Oregon Health & Science University; Center for Coastal Margin Observation & Prediction |
| attribute | NC_GLOBAL | instrument | String | IN SITU/Laboratory Instruments > Chemical Meters/Analyzers > > > FLUOROMETERS |
| attribute | NC_GLOBAL | instrument_vocabulary | String | GCMD Keyword Version: 8.4.1 |
| attribute | NC_GLOBAL | keywords | String | 2022-01-01, 2022-02-01, adjusted, assembled, association, center, chemistry, chlorophyll, chlorophyll_qc, cmop, coastal, collected, color, columbia, concentration, concentration_of_chlorophyll_in_sea_water, crs, data, deployed, deployment, depth2, earth, Earth Science > Oceans > Ocean Chemistry > Chlorophyll, Earth Science > Oceans > Ocean Chemistry > Pigments > Chlorophyll, east, estuary, field, flag, fluorescence, fluorometer, health, identifier, instrument, latitude, level, longitude, margin, mass, mass_concentration_of_chlorophyll_in_sea_water, mass_concentration_of_chlorophyll_in_sea_water status_flag, mean, msl, nanoos, networked, north, northwest, observation, observing, ocean, ocean color, oceanographic, oceans, oregon, pacific, pigments, platform, prediction, prior, processing, quality, raw, raw_chlorophyll, retrieved, river, saturn, science, sea, seawater, station, status, systems, time, timeSeries, uncorrected, unique, university, until, values, water, when |
| attribute | NC_GLOBAL | keywords_vocabulary | String | GCMD Science Keywords |
| attribute | NC_GLOBAL | license | String | This data may be redistributed and used without restriction. Data provided as is with no expressed or implied assurance of quality assurance or quality control |
| attribute | NC_GLOBAL | naming_authority | String | org.stccmop.www |
| attribute | NC_GLOBAL | Northernmost_Northing | double | 46.19973 |
| attribute | NC_GLOBAL | platform | String | In Situ Land-based Platforms > OCEAN PLATFORM/OCEAN STATIONS > COASTAL STATIONS |
| attribute | NC_GLOBAL | platform_vocabulary | String | GCMD Keywords Version 8.4.1 |
| attribute | NC_GLOBAL | processing_level | String | .Variable chlorophyll has been quality assessed. Variable chlorophyll has been subject to preliminary quality assessment. |
| attribute | NC_GLOBAL | product_version | String | 0.9 |
| attribute | NC_GLOBAL | program | String | IOOS,NANOOS,STC-CMOP,NSF STC |
| attribute | NC_GLOBAL | project | String | SATURN |
| attribute | NC_GLOBAL | publisher_email | String | nanoos.dmac at gmail.com |
| attribute | NC_GLOBAL | publisher_institution | String | Northwest Association of Networked Ocean Observing Systems (NANOOS) |
| attribute | NC_GLOBAL | publisher_name | String | NANOOS Data Manager |
| attribute | NC_GLOBAL | publisher_type | String | position |
| attribute | NC_GLOBAL | publisher_url | String | http://www.nanoos.org/![]() |
| attribute | NC_GLOBAL | sea_name | String | Columbia River estuary - Washington/Oregon |
| attribute | NC_GLOBAL | source | String | in-situ observation |
| attribute | NC_GLOBAL | sourceUrl | String | (local files) |
| attribute | NC_GLOBAL | Southernmost_Northing | double | 46.19973 |
| attribute | NC_GLOBAL | standard_name_vocabulary | String | CF Standard Name Table v32 |
| attribute | NC_GLOBAL | subsetVariables | String | crs, platform, instrument, timeSeries, latitude, longitude, depth2, chlorophyll_qc |
| attribute | NC_GLOBAL | summary | String | This file contains seawater data (chlorophyll) collected at SATURN-03, a fixed station in the Columbia River lower estuary, Oregon, USA by the Center for Coastal Margin Observation and Prediction (CMOP), and assembled by Northwest Association of Networked Ocean Observation Systems (Northwest Association of Networked Ocean Observing Systems (NANOOS)). This file contains data from 2022-01-01 to 2022-02-01 from a Turner Designs Cyclops (Fluorometer). This instrument was deployed on 2018-01-18 and was ongoing as of 2022-02-05. The instrument depth was 2.4 m relative to mean sea level (NGVD29), in an overall water depth of approximately 14 m relative to MSL. The measurements reflect a nominal 3.0 minute sampling interval. The mooring used was a pumped system on a fixed mooring, with water pumped from depth to instruments above the water. |
| attribute | NC_GLOBAL | testOutOfDate | String | now-53days |
| attribute | NC_GLOBAL | time_coverage_duration | String | PT325H17M58S |
| attribute | NC_GLOBAL | time_coverage_end | String | 2025-11-14T21:17:59Z |
| attribute | NC_GLOBAL | time_coverage_resolution | String | PT3M |
| attribute | NC_GLOBAL | time_coverage_start | String | 2020-10-01T08:06:00Z |
| attribute | NC_GLOBAL | title | String | Oceanographic data collected from Saturn Estuary Station 03 by Center for Coastal Margin Observation and Prediction (CMOP) and assembled by Northwest Association of Networked Ocean Observation Systems (NANOOS) in the Columbia River Estuary and North East Pacific Ocean |
| attribute | NC_GLOBAL | Westernmost_Easting | double | -123.94001 |
| variable | crs | double | ||
| attribute | crs | _FillValue | double | 9.969209968386869E36 |
| attribute | crs | epsg_code | String | EPSG:4326 |
| attribute | crs | grid_mapping_name | String | latitude_longitude |
| attribute | crs | inverse_flattening | double | 298.257223563 |
| attribute | crs | ioos_category | String | Unknown |
| attribute | crs | long_name | String | CRS |
| attribute | crs | semi_major_axis | double | 6378137.0 |
| variable | platform | int | ||
| attribute | platform | _FillValue | int | -2147483647 |
| attribute | platform | cmop_name | String | saturn03 |
| attribute | platform | ioos_category | String | Unknown |
| attribute | platform | long_name | String | Saturn Estuary Station 03 |
| attribute | platform | missing_value | int | 2147483647 |
| attribute | platform | ncei_code | String | 317F |
| attribute | platform | ncei_name | String | FIXED PLATFORM, MOORINGS |
| variable | instrument | int | ||
| attribute | instrument | _FillValue | int | -2147483647 |
| attribute | instrument | calibration_date | String | 1970-1-1 0:00 |
| attribute | instrument | calibration_report | String | calibration date is a dummy value for testing purposes |
| attribute | instrument | colorBarMaximum | double | 30.0 |
| attribute | instrument | colorBarMinimum | double | 0.03 |
| attribute | instrument | colorBarScale | String | Log |
| attribute | instrument | ioos_category | String | Ocean Color |
| attribute | instrument | long_name | String | Chlorophyll fluorometer |
| attribute | instrument | make_model | String | Turner Designs/Cyclops |
| attribute | instrument | missing_value | int | 2147483647 |
| attribute | instrument | platform | String | platform |
| attribute | instrument | serial_number | String | FL2110-2719 |
| attribute | instrument | standard_name | String | concentration_of_chlorophyll_in_sea_water |
| variable | timeSeries | int | ||
| attribute | timeSeries | _FillValue | int | 2147483647 |
| attribute | timeSeries | actual_range | int | 3026, 4099 |
| attribute | timeSeries | associated_timeSeries | String | 4098 4100 4101 |
| attribute | timeSeries | cf_role | String | timeseries_id |
| attribute | timeSeries | comment | String | the associated_timeSeries attribute represents other deployment ids with the same instrument over the same time period, e.g. pumped from a different depth, calibration, etc. |
| attribute | timeSeries | ioos_category | String | Identifier |
| attribute | timeSeries | long_name | String | Deployment identifier, unique to instrument at a location from when deployed until retrieved from the field |
| variable | time | double | ||
| attribute | time | _CoordinateAxisType | String | Time |
| attribute | time | actual_range | double | 1.60153956E9, 1.763155079E9 |
| attribute | time | axis | String | T |
| attribute | time | calendar | String | gregorian |
| attribute | time | comment | String | Timestamps are added to the data when reaching SATURN01, SATURN03 or SATURN04 or MERTS. If not originating at one of these stations, the data will have been transmitted over a radio link, introducing a small lag, generally less than 1 second. Clocks at the SATURN/MERTS stations mentioned are maintained by NTP. |
| attribute | time | coverage_content_type | String | coordinate |
| attribute | time | ioos_category | String | Time |
| attribute | time | long_name | String | Time |
| attribute | time | standard_name | String | time |
| attribute | time | time_origin | String | 01-JAN-1970 00:00:00 |
| attribute | time | units | String | seconds since 1970-01-01T00:00:00Z |
| variable | latitude | double | ||
| attribute | latitude | _CoordinateAxisType | String | Lat |
| attribute | latitude | _FillValue | double | 9.969209968386869E36 |
| attribute | latitude | actual_range | double | 46.19973, 46.19973 |
| attribute | latitude | axis | String | Y |
| attribute | latitude | colorBarMaximum | double | 90.0 |
| attribute | latitude | colorBarMinimum | double | -90.0 |
| attribute | latitude | comment | String | Derived either by GPS measurements (for buoys) or by estimation from digital maps (for stations placed on existing structures visible on maps). For buoy stations, there is a watch circle which is different from buoy to buoy, but estimated precision is better than 10m error. |
| attribute | latitude | coverage_content_type | String | coordinate |
| attribute | latitude | ioos_category | String | Location |
| attribute | latitude | long_name | String | Nominal latitude of measurement station |
| attribute | latitude | standard_name | String | latitude |
| attribute | latitude | units | String | degrees_north |
| attribute | latitude | valid_max | double | 90.0 |
| attribute | latitude | valid_min | double | -90.0 |
| variable | longitude | double | ||
| attribute | longitude | _CoordinateAxisType | String | Lon |
| attribute | longitude | _FillValue | double | 9.969209968386869E36 |
| attribute | longitude | actual_range | double | -123.94001, -123.94001 |
| attribute | longitude | axis | String | X |
| attribute | longitude | colorBarMaximum | double | 180.0 |
| attribute | longitude | colorBarMinimum | double | -180.0 |
| attribute | longitude | comment | String | Derived either by GPS measurements (for buoys) or by estimation from digital maps (for stations placed on existing structures visible on maps). For buoy stations, there is a watch circle which is different from buoy to buoy, but estimated precision is better than 10m error. |
| attribute | longitude | coverage_content_type | String | coordinate |
| attribute | longitude | ioos_category | String | Location |
| attribute | longitude | long_name | String | Nominal longitude of measurement station |
| attribute | longitude | standard_name | String | longitude |
| attribute | longitude | units | String | degrees_east |
| attribute | longitude | valid_max | double | 180.0 |
| attribute | longitude | valid_min | double | -180.0 |
| variable | depth2 | double | ||
| attribute | depth2 | _FillValue | double | 9.969209968386869E36 |
| attribute | depth2 | actual_range | double | 240.0, 240.0 |
| attribute | depth2 | axis | String | Z |
| attribute | depth2 | colorBarMaximum | double | 8000.0 |
| attribute | depth2 | colorBarMinimum | double | -8000.0 |
| attribute | depth2 | colorBarPalette | String | TopographyDepth |
| attribute | depth2 | comment | String | The nominal depth was measured relative to mean sea level. Sea-level reference was established at a station by using a pressure sensor to generate an approximate depth record over a 1 month period (or longer), and then the local LLW depth is corrected by the LLW depth at Tongue Point relative to National Geodetic Vertical Datum of 1929 (NGVD29) to give a local depth relative to NGVD29. |
| attribute | depth2 | coverage_content_type | String | coordinate |
| attribute | depth2 | ioos_category | String | Location |
| attribute | depth2 | long_name | String | Nominal depth of measurement station |
| attribute | depth2 | positive | String | down |
| attribute | depth2 | standard_name | String | depth |
| attribute | depth2 | units | String | cm |
| attribute | depth2 | valid_max | double | 8000.0 |
| attribute | depth2 | valid_min | double | -1000.0 |
| variable | chlorophyll | double | ||
| attribute | chlorophyll | _FillValue | double | 9.969209968386869E36 |
| attribute | chlorophyll | actual_range | double | 0.0, 38.21 |
| attribute | chlorophyll | ancillary_variables | String | platform instrument chlorophyll_qc raw_chlorophyll |
| attribute | chlorophyll | colorBarMaximum | double | 30.0 |
| attribute | chlorophyll | colorBarMinimum | double | 0.03 |
| attribute | chlorophyll | colorBarScale | String | Log |
| attribute | chlorophyll | coverage_content_type | String | physicalMeasurement |
| attribute | chlorophyll | instrument | String | instrument |
| attribute | chlorophyll | ioos_category | String | Ocean Color |
| attribute | chlorophyll | long_name | String | Chlorophyll fluorescence |
| attribute | chlorophyll | platform | String | platform |
| attribute | chlorophyll | source | String | measurement reported by the instrument |
| attribute | chlorophyll | standard_name | String | mass_concentration_of_chlorophyll_in_sea_water |
| attribute | chlorophyll | units | String | microg/l |
| attribute | chlorophyll | varname | String | chlorophyll |
| variable | chlorophyll_qc | byte | ||
| attribute | chlorophyll_qc | _FillValue | byte | -127 |
| attribute | chlorophyll_qc | actual_range | byte | 0, 0 |
| attribute | chlorophyll_qc | colorBarMaximum | double | 10.0 |
| attribute | chlorophyll_qc | colorBarMinimum | double | 0.0 |
| attribute | chlorophyll_qc | flag_meanings | String | no_qc_performed good_data probably_good_data value_chaged bad_data_that_are_potentially_useful bad_data not_used not_used interpolated_value missing_value |
| attribute | chlorophyll_qc | flag_values | byte | 0, 1, 2, 3, 4, 5, 6, 7, 8, 9 |
| attribute | chlorophyll_qc | ioos_category | String | Quality |
| attribute | chlorophyll_qc | long_name | String | Chlorophyll fluorescence Quality Flag |
| attribute | chlorophyll_qc | notes | String | Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2009-08-24 23:46:06.999995 UTC to 2009-08-24 23:46:06.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2010-10-15 21:22:27.999994 UTC to 2010-10-15 21:22:38 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-06-18 15:30:10.999997 UTC to 2011-06-18 15:30:21.000003 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:32.999994 UTC to 2011-07-01 19:01:34.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:32.999994 UTC to 2011-07-01 19:01:34.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 20:43:34 UTC to 2011-07-02 12:29:35.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-10 19:11:55.999999 UTC to 2011-07-10 19:11:55.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-12-29 15:44:23.999991 UTC to 2011-12-29 15:44:33.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-08-04 16:38:05.999992 UTC to 2012-08-04 16:38:15.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:35.999998 UTC to 2012-04-25 00:05:33.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-05-30 20:49:06.999995 UTC to 2012-05-30 20:49:06.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-06-12 23:05:20.999996 UTC to 2012-06-15 17:11:23.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:35.999998 UTC to 2012-04-25 00:05:33.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-05-30 20:49:06.999995 UTC to 2012-05-30 20:49:06.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-06-12 23:05:20.999996 UTC to 2012-06-15 17:11:23.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-08-04 16:38:05.999992 UTC to 2012-08-04 16:38:15.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-07-15 00:23:21.999993 UTC to 2013-07-16 17:44:29.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-10-04 13:19:32.999994 UTC to 2013-10-07 21:15:40.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-06-22 06:01:20.999997 UTC to 2014-06-26 20:31:34.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-06-22 06:01:20.999997 UTC to 2014-06-26 20:31:34.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-07-06 07:01:34.999998 UTC to 2014-07-06 07:01:34.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-07-06 07:01:34.999998 UTC to 2014-07-06 07:01:34.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-05-24 22:08:31.999999 UTC to 2015-05-25 00:09:05.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-05-26 11:58:31.999998 UTC to 2015-05-26 11:58:31.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-05-29 14:24:31.999999 UTC to 2015-05-29 14:24:31.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-03 17:38:31.999999 UTC to 2015-06-03 17:38:31.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-24 20:05:23.999999 UTC to 2015-06-24 20:05:23.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-06-25 16:45:24.000001 UTC to 2015-06-25 16:45:24.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-08-03 21:01:22.999996 UTC to 2015-08-03 21:01:22.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-04 18:57:21.999992 UTC to 2015-08-04 18:57:21.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-11 12:13:21.999998 UTC to 2015-08-11 12:13:21.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-10-04 22:07:21.999996 UTC to 2015-10-04 22:07:21.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-10-05 21:31:21.999994 UTC to 2015-10-05 21:31:21.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-10-07 19:00:00 UTC to 2015-10-08 23:00:00 UTC flagged bad (tail of data after buoy recovery) Data with values less than False, during the time period from 2015-10-07 19:53:04.999995 UTC to 2015-10-08 21:11:04.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-10-07 19:00:00 UTC to 2015-10-08 23:00:00 UTC flagged bad (tail of data after buoy recovery) Data with values less than False, during the time period from 2015-10-07 19:00:00 UTC to 2015-10-08 23:00:00 UTC flagged bad (tail of data after buoy recovery) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-07-06 18:15:00 UTC to 2016-07-06 18:50:00 UTC flagged bad (spike of bad data across all depths) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 14:48:20.999993 UTC to 2016-10-11 20:34:20.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 18:09:13.000001 UTC to 2017-10-31 19:59:13 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2018-07-01 21:26:45.999993 UTC to 2018-07-01 21:26:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-07-17 16:49:07.999993 UTC to 2018-07-17 16:49:07.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2018-08-03 05:51:31.999993 UTC to 2018-08-03 05:51:31.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-08 22:11:41 UTC to 2018-08-08 22:11:41 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-10 15:39:42.999993 UTC to 2018-08-10 15:39:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-11 14:39:44.000001 UTC to 2018-08-11 14:39:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-15 04:45:48.999996 UTC to 2018-08-15 04:45:48.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-15 05:25:49.999998 UTC to 2018-08-15 05:25:49.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-16 11:03:51.000001 UTC to 2018-08-16 11:03:51.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-19 23:29:56.000002 UTC to 2018-08-19 23:29:56.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-20 14:35:56.999995 UTC to 2018-08-20 14:35:56.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-26 15:24:05.999996 UTC to 2018-08-26 15:24:05.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2018-07-01 21:26:45.999993 UTC to 2018-07-01 21:26:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-07-17 16:49:07.999993 UTC to 2018-07-17 16:49:07.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2018-08-03 05:51:31.999993 UTC to 2018-08-03 05:51:31.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-08 22:11:41 UTC to 2018-08-08 22:11:41 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-10 15:39:42.999993 UTC to 2018-08-10 15:39:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-11 14:39:44.000001 UTC to 2018-08-11 14:39:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-15 04:45:48.999996 UTC to 2018-08-15 04:45:48.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-15 05:25:49.999998 UTC to 2018-08-15 05:25:49.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-16 11:03:51.000001 UTC to 2018-08-16 11:03:51.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-19 23:29:56.000002 UTC to 2018-08-19 23:29:56.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-20 14:35:56.999995 UTC to 2018-08-20 14:35:56.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-08-26 15:24:05.999996 UTC to 2018-08-26 15:24:05.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-29 01:50:39.999996 UTC to 2019-05-29 01:50:45 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-29 11:12:39.999998 UTC to 2019-05-29 11:12:45.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-07 11:48:40 UTC to 2019-07-07 11:48:43.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-16 15:28:39.999998 UTC to 2019-07-16 15:28:43.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-21 16:18:40 UTC to 2019-07-21 16:18:43.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-24 19:48:39.999994 UTC to 2019-07-24 19:48:43.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-27 19:34:39.999993 UTC to 2019-07-27 19:34:43.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-08-12 02:34:40 UTC to 2019-08-12 02:34:43.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-10-29 11:06:40 UTC to 2019-10-29 11:06:42.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-29 01:50:39.999996 UTC to 2019-05-29 01:50:45 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-29 11:12:39.999998 UTC to 2019-05-29 11:12:45.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-07 11:48:40 UTC to 2019-07-07 11:48:43.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-16 15:28:39.999998 UTC to 2019-07-16 15:28:43.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-21 16:18:40 UTC to 2019-07-21 16:18:43.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-24 19:48:39.999994 UTC to 2019-07-24 19:48:43.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-27 19:34:39.999993 UTC to 2019-07-27 19:34:43.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-08-12 02:34:40 UTC to 2019-08-12 02:34:43.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-10-29 11:06:40 UTC to 2019-10-29 11:06:42.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-02 00:43:34.999992 UTC to 2021-08-02 00:43:53.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 11:41:17.999994 UTC to 2021-08-05 11:43:17.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 12:17:19 UTC to 2021-08-06 12:17:19 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-10 01:55:17.999997 UTC to 2021-08-10 01:55:17.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-12 11:33:17.999992 UTC to 2021-08-12 11:33:17.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-12 16:33:17.999996 UTC to 2021-08-12 16:33:17.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-13 13:33:19 UTC to 2021-08-13 13:33:19 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 09:33:17.999999 UTC to 2021-08-17 09:33:17.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 19:35:17.999998 UTC to 2021-08-17 19:35:17.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-19 16:09:18.000001 UTC to 2021-08-19 16:09:18.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-23 13:25:17.999994 UTC to 2021-08-23 13:25:17.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-24 06:45:25.999993 UTC to 2021-08-24 06:45:25.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-26 02:29:17.999996 UTC to 2021-08-26 02:29:17.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-26 23:27:17.999994 UTC to 2021-08-26 23:27:17.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-28 18:21:18.000002 UTC to 2021-08-28 18:21:18.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-30 18:59:17.999996 UTC to 2021-08-30 18:59:17.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-03 01:23:18.000001 UTC to 2021-09-03 01:23:18.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-06 08:05:17.999992 UTC to 2021-09-06 08:05:17.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-06 21:17:17.999996 UTC to 2021-09-06 21:17:17.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-11 04:03:17.999992 UTC to 2021-09-11 04:03:17.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-30 22:31:16.999998 UTC to 2021-09-30 22:31:16.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-10-04 15:57:16.999999 UTC to 2021-10-04 15:57:16.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-08 16:59:26.999995 UTC to 2021-10-10 16:57:16.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-10 16:59:16.999999 UTC to 2021-10-10 16:59:16.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-10 17:01:17.000001 UTC to 2021-10-20 01:47:17.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-20 01:49:16.999994 UTC to 2021-10-20 01:49:16.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-20 01:51:16.999997 UTC to 2021-10-21 01:31:16.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-21 01:33:17.000001 UTC to 2021-10-21 01:33:17.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-21 01:35:16.999994 UTC to 2021-10-22 19:19:17.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-02 00:43:34.999992 UTC to 2021-08-02 00:43:53.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 11:41:17.999994 UTC to 2021-08-05 11:43:17.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 12:17:19 UTC to 2021-08-06 12:17:19 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-10 01:55:17.999997 UTC to 2021-08-10 01:55:17.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-12 11:33:17.999992 UTC to 2021-08-12 11:33:17.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-12 16:33:17.999996 UTC to 2021-08-12 16:33:17.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-13 13:33:19 UTC to 2021-08-13 13:33:19 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 09:33:17.999999 UTC to 2021-08-17 09:33:17.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 19:35:17.999998 UTC to 2021-08-17 19:35:17.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-19 16:09:18.000001 UTC to 2021-08-19 16:09:18.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-23 13:25:17.999994 UTC to 2021-08-23 13:25:17.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-24 06:45:25.999993 UTC to 2021-08-24 06:45:25.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-26 02:29:17.999996 UTC to 2021-08-26 02:29:17.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-26 23:27:17.999994 UTC to 2021-08-26 23:27:17.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-28 18:21:18.000002 UTC to 2021-08-28 18:21:18.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-30 18:59:17.999996 UTC to 2021-08-30 18:59:17.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-03 01:23:18.000001 UTC to 2021-09-03 01:23:18.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-06 08:05:17.999992 UTC to 2021-09-06 08:05:17.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-06 21:17:17.999996 UTC to 2021-09-06 21:17:17.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-11 04:03:17.999992 UTC to 2021-09-11 04:03:17.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-30 22:31:16.999998 UTC to 2021-09-30 22:31:16.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-10-04 15:57:16.999999 UTC to 2021-10-04 15:57:16.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-08 16:59:26.999995 UTC to 2021-10-10 16:57:16.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-10 16:59:16.999999 UTC to 2021-10-10 16:59:16.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-10 17:01:17.000001 UTC to 2021-10-20 01:47:17.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-20 01:49:16.999994 UTC to 2021-10-20 01:49:16.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-20 01:51:16.999997 UTC to 2021-10-21 01:31:16.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-21 01:33:17.000001 UTC to 2021-10-21 01:33:17.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-21 01:35:16.999994 UTC to 2021-10-22 19:19:17.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-05-20 07:01:46.999993 UTC to 2022-05-20 16:55:44.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-26 08:55:44.999998 UTC to 2022-05-26 08:55:44.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-01 10:51:44.000001 UTC to 2022-06-01 10:51:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-02 22:27:45.000001 UTC to 2022-06-02 22:27:45.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-03 15:43:43.999993 UTC to 2022-06-03 15:43:43.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-04 07:05:43.999995 UTC to 2022-06-04 07:05:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-06 11:53:44.999996 UTC to 2022-06-06 11:53:44.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-09 14:51:43.999998 UTC to 2022-06-09 14:51:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-12 16:15:43.999999 UTC to 2022-06-12 16:15:43.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-18 19:19:43.999995 UTC to 2022-06-18 19:19:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-22 17:09:43.999997 UTC to 2022-06-22 17:09:43.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-23 11:35:43.999995 UTC to 2022-06-23 11:35:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-24 14:17:43.999999 UTC to 2022-06-24 14:17:43.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-01 12:17:43.999996 UTC to 2022-07-01 12:17:43.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-03 22:07:43.999998 UTC to 2022-07-03 22:07:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-05 19:49:43.999998 UTC to 2022-07-05 19:49:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-14 14:25:44.000001 UTC to 2022-07-14 14:25:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-15 09:03:43.999995 UTC to 2022-07-15 09:03:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-24 06:05:43.999998 UTC to 2022-07-24 06:05:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-27 14:31:42.999995 UTC to 2022-07-27 14:31:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-29 22:31:43.999992 UTC to 2022-07-29 22:31:43.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-08-01 16:51:44.000001 UTC to 2022-08-01 16:51:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-04 08:37:42.999993 UTC to 2022-08-04 08:37:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-08 10:57:44 UTC to 2022-08-08 10:57:44 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-12 09:27:42.999995 UTC to 2022-08-12 09:27:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-14 16:47:43.000001 UTC to 2022-08-14 16:47:43.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-19 06:27:42.999995 UTC to 2022-08-19 06:27:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-19 18:41:42.999996 UTC to 2022-08-19 18:41:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-19 21:19:42.999994 UTC to 2022-08-19 21:19:42.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-21 20:25:42.999996 UTC to 2022-08-21 20:25:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-23 05:23:42.999993 UTC to 2022-08-23 05:23:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-27 06:29:42.999998 UTC to 2022-08-27 06:29:42.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-31 15:27:42.999995 UTC to 2022-08-31 15:27:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-31 20:21:43 UTC to 2022-08-31 20:21:43 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-09-01 09:41:42.999996 UTC to 2022-09-01 09:41:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-02 20:51:42.999993 UTC to 2022-09-02 20:51:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-04 08:39:42.999996 UTC to 2022-09-04 08:39:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-05 16:23:42.999996 UTC to 2022-09-05 16:23:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-05 22:37:42.999997 UTC to 2022-09-05 22:37:42.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-07 18:17:43.000001 UTC to 2022-09-07 18:17:43.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-08 03:25:42.999993 UTC to 2022-09-08 03:25:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-10 22:37:42.999997 UTC to 2022-09-10 22:37:42.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-17 03:19:41.999999 UTC to 2022-09-17 03:19:41.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-23 22:57:42.000001 UTC to 2022-09-23 22:57:42.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-24 17:45:42 UTC to 2022-09-24 17:45:42 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-30 05:27:41.999994 UTC to 2022-09-30 05:27:41.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-10-02 12:21:41.999992 UTC to 2022-10-02 12:21:41.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-04 00:27:42.000001 UTC to 2022-10-04 00:27:42.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-05 20:25:42.000001 UTC to 2022-10-05 20:25:42.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-06 03:35:41.999992 UTC to 2022-10-06 03:35:41.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-06 19:25:41.999995 UTC to 2022-10-06 19:25:41.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-06 23:03:42 UTC to 2022-10-06 23:03:42 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-08 06:57:41.999994 UTC to 2022-10-08 06:57:41.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-09 14:23:41.999998 UTC to 2022-10-09 14:23:41.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-16 08:51:41.999999 UTC to 2022-10-16 08:51:41.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-20 08:59:42 UTC to 2022-10-20 08:59:42 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-21 23:41:41.999994 UTC to 2022-10-21 23:41:41.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-24 07:05:41.999996 UTC to 2022-10-24 07:05:41.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-25 05:33:41.999993 UTC to 2022-10-25 05:33:41.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-28 02:05:41.999992 UTC to 2022-10-28 02:05:41.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-30 16:23:41.999992 UTC to 2022-10-30 16:23:41.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-11-03 10:07:41.999999 UTC to 2022-11-03 10:07:41.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-05 03:31:41.999997 UTC to 2022-11-05 03:31:41.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-06 12:49:41.000001 UTC to 2022-11-06 12:49:41.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-13 03:15:40.999992 UTC to 2022-11-13 03:15:40.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-13 07:05:40.999994 UTC to 2022-11-13 07:05:40.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-15 23:25:41 UTC to 2022-11-15 23:25:41 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-21 05:11:41 UTC to 2022-11-21 05:11:41 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-22 05:41:40.999993 UTC to 2022-11-22 05:41:40.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-26 04:45:40.999992 UTC to 2022-11-26 04:45:40.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-26 18:01:40.999992 UTC to 2022-11-26 18:01:40.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-12-01 23:41:40.999993 UTC to 2022-12-01 23:41:40.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-12-02 12:11:40.999996 UTC to 2022-12-02 12:11:40.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-12-03 09:19:40.999998 UTC to 2022-12-03 09:19:40.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-12-03 12:13:40.999999 UTC to 2022-12-03 12:13:40.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-05-20 07:01:46.999993 UTC to 2022-05-20 16:55:44.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-26 08:55:44.999998 UTC to 2022-05-26 08:55:44.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-01 10:51:44.000001 UTC to 2022-06-01 10:51:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-02 22:27:45.000001 UTC to 2022-06-02 22:27:45.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-03 15:43:43.999993 UTC to 2022-06-03 15:43:43.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-04 07:05:43.999995 UTC to 2022-06-04 07:05:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-06 11:53:44.999996 UTC to 2022-06-06 11:53:44.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-09 14:51:43.999998 UTC to 2022-06-09 14:51:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-12 16:15:43.999999 UTC to 2022-06-12 16:15:43.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-18 19:19:43.999995 UTC to 2022-06-18 19:19:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-22 17:09:43.999997 UTC to 2022-06-22 17:09:43.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-23 11:35:43.999995 UTC to 2022-06-23 11:35:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-24 14:17:43.999999 UTC to 2022-06-24 14:17:43.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-01 12:17:43.999996 UTC to 2022-07-01 12:17:43.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-03 22:07:43.999998 UTC to 2022-07-03 22:07:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-05 19:49:43.999998 UTC to 2022-07-05 19:49:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-14 14:25:44.000001 UTC to 2022-07-14 14:25:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-15 09:03:43.999995 UTC to 2022-07-15 09:03:43.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-24 06:05:43.999998 UTC to 2022-07-24 06:05:43.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-27 14:31:42.999995 UTC to 2022-07-27 14:31:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-29 22:31:43.999992 UTC to 2022-07-29 22:31:43.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-08-01 16:51:44.000001 UTC to 2022-08-01 16:51:44.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-04 08:37:42.999993 UTC to 2022-08-04 08:37:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-08 10:57:44 UTC to 2022-08-08 10:57:44 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-12 09:27:42.999995 UTC to 2022-08-12 09:27:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-14 16:47:43.000001 UTC to 2022-08-14 16:47:43.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-19 06:27:42.999995 UTC to 2022-08-19 06:27:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-19 18:41:42.999996 UTC to 2022-08-19 18:41:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-19 21:19:42.999994 UTC to 2022-08-19 21:19:42.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-21 20:25:42.999996 UTC to 2022-08-21 20:25:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-23 05:23:42.999993 UTC to 2022-08-23 05:23:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-27 06:29:42.999998 UTC to 2022-08-27 06:29:42.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-31 15:27:42.999995 UTC to 2022-08-31 15:27:42.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-08-31 20:21:43 UTC to 2022-08-31 20:21:43 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-09-01 09:41:42.999996 UTC to 2022-09-01 09:41:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-02 20:51:42.999993 UTC to 2022-09-02 20:51:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-04 08:39:42.999996 UTC to 2022-09-04 08:39:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-05 16:23:42.999996 UTC to 2022-09-05 16:23:42.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-05 22:37:42.999997 UTC to 2022-09-05 22:37:42.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-07 18:17:43.000001 UTC to 2022-09-07 18:17:43.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-08 03:25:42.999993 UTC to 2022-09-08 03:25:42.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-10 22:37:42.999997 UTC to 2022-09-10 22:37:42.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-17 03:19:41.999999 UTC to 2022-09-17 03:19:41.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-23 22:57:42.000001 UTC to 2022-09-23 22:57:42.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-24 17:45:42 UTC to 2022-09-24 17:45:42 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-09-30 05:27:41.999994 UTC to 2022-09-30 05:27:41.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-10-02 12:21:41.999992 UTC to 2022-10-02 12:21:41.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-04 00:27:42.000001 UTC to 2022-10-04 00:27:42.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-05 20:25:42.000001 UTC to 2022-10-05 20:25:42.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-06 03:35:41.999992 UTC to 2022-10-06 03:35:41.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-06 19:25:41.999995 UTC to 2022-10-06 19:25:41.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-06 23:03:42 UTC to 2022-10-06 23:03:42 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-08 06:57:41.999994 UTC to 2022-10-08 06:57:41.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-09 14:23:41.999998 UTC to 2022-10-09 14:23:41.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-16 08:51:41.999999 UTC to 2022-10-16 08:51:41.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-20 08:59:42 UTC to 2022-10-20 08:59:42 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-21 23:41:41.999994 UTC to 2022-10-21 23:41:41.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-24 07:05:41.999996 UTC to 2022-10-24 07:05:41.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-25 05:33:41.999993 UTC to 2022-10-25 05:33:41.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-28 02:05:41.999992 UTC to 2022-10-28 02:05:41.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-10-30 16:23:41.999992 UTC to 2022-10-30 16:23:41.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-11-03 10:07:41.999999 UTC to 2022-11-03 10:07:41.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-05 03:31:41.999997 UTC to 2022-11-05 03:31:41.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-06 12:49:41.000001 UTC to 2022-11-06 12:49:41.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-13 03:15:40.999992 UTC to 2022-11-13 03:15:40.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-13 07:05:40.999994 UTC to 2022-11-13 07:05:40.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-15 23:25:41 UTC to 2022-11-15 23:25:41 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-21 05:11:41 UTC to 2022-11-21 05:11:41 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-22 05:41:40.999993 UTC to 2022-11-22 05:41:40.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-26 04:45:40.999992 UTC to 2022-11-26 04:45:40.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-11-26 18:01:40.999992 UTC to 2022-11-26 18:01:40.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-12-01 23:41:40.999993 UTC to 2022-12-01 23:41:40.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-12-02 12:11:40.999996 UTC to 2022-12-02 12:11:40.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-12-03 09:19:40.999998 UTC to 2022-12-03 09:19:40.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-12-03 12:13:40.999999 UTC to 2022-12-03 12:13:40.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-05-27 20:45:02 UTC to 2016-05-27 20:45:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 20:55:02 UTC to 2016-05-27 20:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:05:02 UTC to 2016-05-27 21:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:15:15 UTC to 2016-05-27 21:15:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:25:03 UTC to 2016-05-27 21:25:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:35:02 UTC to 2016-05-27 21:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:45:07 UTC to 2016-05-27 21:45:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:55:02 UTC to 2016-05-27 21:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:05:02 UTC to 2016-05-27 22:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:15:02 UTC to 2016-05-27 22:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:25:02 UTC to 2016-05-27 22:25:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:35:02 UTC to 2016-05-27 22:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:45:01 UTC to 2016-05-27 22:45:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:55:12 UTC to 2016-05-27 22:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:05:02 UTC to 2016-05-27 23:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:15:01 UTC to 2016-05-27 23:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:35:02 UTC to 2016-05-27 23:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:55:02 UTC to 2016-05-27 23:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:15:01 UTC to 2016-05-28 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:35:01 UTC to 2016-05-28 00:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:55:01 UTC to 2016-05-28 00:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:15:15 UTC to 2016-05-28 01:15:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:35:01 UTC to 2016-05-28 01:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:55:01 UTC to 2016-05-28 01:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:15:01 UTC to 2016-05-28 02:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:35:01 UTC to 2016-05-28 02:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:55:01 UTC to 2016-05-28 02:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:15:01 UTC to 2016-05-28 03:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:35:01 UTC to 2016-05-28 03:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:55:05 UTC to 2016-05-28 03:55:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:15:01 UTC to 2016-05-28 04:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:35:02 UTC to 2016-05-28 04:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:55:01 UTC to 2016-05-28 04:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:15:02 UTC to 2016-05-28 05:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:35:02 UTC to 2016-05-28 05:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:55:02 UTC to 2016-05-28 05:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:15:01 UTC to 2016-05-28 06:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:35:03 UTC to 2016-05-28 06:35:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:55:01 UTC to 2016-05-28 06:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:15:01 UTC to 2016-05-28 07:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:35:01 UTC to 2016-05-28 07:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:55:01 UTC to 2016-05-28 07:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:15:01 UTC to 2016-05-28 08:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:35:01 UTC to 2016-05-28 08:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:55:01 UTC to 2016-05-28 08:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:15:01 UTC to 2016-05-28 09:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:35:01 UTC to 2016-05-28 09:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:55:01 UTC to 2016-05-28 09:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:15:01 UTC to 2016-05-28 10:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:35:01 UTC to 2016-05-28 10:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:55:01 UTC to 2016-05-28 10:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:15:01 UTC to 2016-05-28 11:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:35:01 UTC to 2016-05-28 11:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:55:01 UTC to 2016-05-28 11:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:15:01 UTC to 2016-05-28 12:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:35:01 UTC to 2016-05-28 12:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:55:01 UTC to 2016-05-28 12:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:15:01 UTC to 2016-05-28 13:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:35:01 UTC to 2016-05-28 13:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:55:01 UTC to 2016-05-28 13:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:15:01 UTC to 2016-05-28 14:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:35:01 UTC to 2016-05-28 14:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:55:01 UTC to 2016-05-28 14:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:15:01 UTC to 2016-05-28 15:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:35:01 UTC to 2016-05-28 15:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:55:26 UTC to 2016-05-28 15:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:15:01 UTC to 2016-05-28 16:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:35:07 UTC to 2016-05-28 16:35:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:55:01 UTC to 2016-05-28 16:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:15:10 UTC to 2016-05-28 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:35:01 UTC to 2016-05-28 17:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:55:01 UTC to 2016-05-28 17:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:15:01 UTC to 2016-05-28 18:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:35:01 UTC to 2016-05-28 18:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:55:03 UTC to 2016-05-28 18:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:15:01 UTC to 2016-05-28 19:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:35:01 UTC to 2016-05-28 19:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:55:01 UTC to 2016-05-28 19:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:15:01 UTC to 2016-05-28 20:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:35:01 UTC to 2016-05-28 20:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:55:01 UTC to 2016-05-28 20:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:15:01 UTC to 2016-05-28 21:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:35:01 UTC to 2016-05-28 21:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:55:01 UTC to 2016-05-28 21:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 22:15:03 UTC to 2016-05-28 22:15:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 22:55:01 UTC to 2016-05-28 22:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:15:44 UTC to 2016-05-28 23:16:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:35:01 UTC to 2016-05-28 23:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:55:03 UTC to 2016-05-28 23:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:15:01 UTC to 2016-05-29 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:35:01 UTC to 2016-05-29 00:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:55:05 UTC to 2016-05-29 00:55:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:15:01 UTC to 2016-05-29 01:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:35:01 UTC to 2016-05-29 01:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:55:01 UTC to 2016-05-29 01:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 02:35:00 UTC to 2016-05-29 02:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 02:55:00 UTC to 2016-05-29 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:15:01 UTC to 2016-05-29 03:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:35:01 UTC to 2016-05-29 03:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:55:00 UTC to 2016-05-29 03:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:15:00 UTC to 2016-05-29 04:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:35:00 UTC to 2016-05-29 04:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:55:01 UTC to 2016-05-29 04:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:15:00 UTC to 2016-05-29 05:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:35:02 UTC to 2016-05-29 05:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:55:00 UTC to 2016-05-29 05:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:15:00 UTC to 2016-05-29 06:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:35:01 UTC to 2016-05-29 06:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:55:00 UTC to 2016-05-29 06:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:15:00 UTC to 2016-05-29 07:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:35:00 UTC to 2016-05-29 07:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:55:00 UTC to 2016-05-29 07:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:15:00 UTC to 2016-05-29 08:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:35:00 UTC to 2016-05-29 08:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:55:27 UTC to 2016-05-29 08:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:15:00 UTC to 2016-05-29 09:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:35:00 UTC to 2016-05-29 09:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:55:00 UTC to 2016-05-29 09:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:15:01 UTC to 2016-05-29 10:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:35:00 UTC to 2016-05-29 10:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:55:00 UTC to 2016-05-29 10:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:15:00 UTC to 2016-05-29 11:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:35:00 UTC to 2016-05-29 11:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:55:01 UTC to 2016-05-29 11:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:15:01 UTC to 2016-05-29 12:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:35:00 UTC to 2016-05-29 12:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:55:00 UTC to 2016-05-29 12:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:15:01 UTC to 2016-05-29 13:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:35:04 UTC to 2016-05-29 13:35:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:55:00 UTC to 2016-05-29 13:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:15:01 UTC to 2016-05-29 14:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:35:02 UTC to 2016-05-29 14:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:55:00 UTC to 2016-05-29 14:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:15:00 UTC to 2016-05-29 15:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:35:00 UTC to 2016-05-29 15:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:55:00 UTC to 2016-05-29 15:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:15:00 UTC to 2016-05-29 16:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:35:00 UTC to 2016-05-29 16:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:56:42 UTC to 2016-05-29 16:57:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:15:00 UTC to 2016-05-29 17:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:35:06 UTC to 2016-05-29 17:35:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:55:00 UTC to 2016-05-29 17:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:15:00 UTC to 2016-05-29 18:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:35:00 UTC to 2016-05-29 18:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:55:01 UTC to 2016-05-29 18:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:15:00 UTC to 2016-05-29 19:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:35:00 UTC to 2016-05-29 19:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:55:00 UTC to 2016-05-29 19:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:15:19 UTC to 2016-05-29 20:15:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:35:04 UTC to 2016-05-29 20:35:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:55:00 UTC to 2016-05-29 20:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:15:00 UTC to 2016-05-29 21:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:35:00 UTC to 2016-05-29 21:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:55:00 UTC to 2016-05-29 21:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:15:00 UTC to 2016-05-29 22:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:35:00 UTC to 2016-05-29 22:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:55:00 UTC to 2016-05-29 22:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:15:11 UTC to 2016-05-29 23:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:35:07 UTC to 2016-05-29 23:35:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:55:00 UTC to 2016-05-29 23:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:15:00 UTC to 2016-05-30 00:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:35:00 UTC to 2016-05-30 00:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:55:00 UTC to 2016-05-30 00:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:15:00 UTC to 2016-05-30 01:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:35:00 UTC to 2016-05-30 01:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:55:00 UTC to 2016-05-30 01:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:15:02 UTC to 2016-05-30 02:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:35:01 UTC to 2016-05-30 02:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:55:00 UTC to 2016-05-30 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:15:00 UTC to 2016-05-30 03:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:35:00 UTC to 2016-05-30 03:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:55:00 UTC to 2016-05-30 03:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:15:00 UTC to 2016-05-30 04:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:35:00 UTC to 2016-05-30 04:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:55:00 UTC to 2016-05-30 04:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:15:00 UTC to 2016-05-30 05:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:35:00 UTC to 2016-05-30 05:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:55:00 UTC to 2016-05-30 05:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:14:59 UTC to 2016-05-30 06:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:34:59 UTC to 2016-05-30 06:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:54:59 UTC to 2016-05-30 06:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:14:59 UTC to 2016-05-30 07:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:34:59 UTC to 2016-05-30 07:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:55:00 UTC to 2016-05-30 07:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:15:00 UTC to 2016-05-30 08:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:35:00 UTC to 2016-05-30 08:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:55:00 UTC to 2016-05-30 08:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:15:00 UTC to 2016-05-30 09:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:35:00 UTC to 2016-05-30 09:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:55:00 UTC to 2016-05-30 09:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:14:59 UTC to 2016-05-30 10:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:34:59 UTC to 2016-05-30 10:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:54:59 UTC to 2016-05-30 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:14:59 UTC to 2016-05-30 11:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:35:00 UTC to 2016-05-30 11:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:54:59 UTC to 2016-05-30 11:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:14:59 UTC to 2016-05-30 12:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:34:59 UTC to 2016-05-30 12:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:54:59 UTC to 2016-05-30 12:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:14:59 UTC to 2016-05-30 13:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:34:59 UTC to 2016-05-30 13:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:54:59 UTC to 2016-05-30 13:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:14:59 UTC to 2016-05-30 14:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:34:59 UTC to 2016-05-30 14:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:54:59 UTC to 2016-05-30 14:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:14:59 UTC to 2016-05-30 15:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:34:59 UTC to 2016-05-30 15:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:54:59 UTC to 2016-05-30 15:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:15:01 UTC to 2016-05-30 16:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:34:59 UTC to 2016-05-30 16:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:55:01 UTC to 2016-05-30 16:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:14:59 UTC to 2016-05-30 17:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:34:59 UTC to 2016-05-30 17:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:55:00 UTC to 2016-05-30 17:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:14:59 UTC to 2016-05-30 18:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:35:06 UTC to 2016-05-30 18:35:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:54:59 UTC to 2016-05-30 18:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:14:59 UTC to 2016-05-30 19:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:34:59 UTC to 2016-05-30 19:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:54:59 UTC to 2016-05-30 19:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:14:59 UTC to 2016-05-30 20:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:34:59 UTC to 2016-05-30 20:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:54:59 UTC to 2016-05-30 20:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:14:59 UTC to 2016-05-30 21:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:34:59 UTC to 2016-05-30 21:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:54:59 UTC to 2016-05-30 21:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:14:59 UTC to 2016-05-30 22:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:34:59 UTC to 2016-05-30 22:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:54:59 UTC to 2016-05-30 22:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:14:59 UTC to 2016-05-30 23:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:34:59 UTC to 2016-05-30 23:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:54:59 UTC to 2016-05-30 23:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:14:59 UTC to 2016-05-31 00:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:34:59 UTC to 2016-05-31 00:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:54:59 UTC to 2016-05-31 00:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:14:59 UTC to 2016-05-31 01:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:34:59 UTC to 2016-05-31 01:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:54:59 UTC to 2016-05-31 01:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:14:59 UTC to 2016-05-31 02:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:34:59 UTC to 2016-05-31 02:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:55:00 UTC to 2016-05-31 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:14:59 UTC to 2016-05-31 03:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:34:59 UTC to 2016-05-31 03:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:54:59 UTC to 2016-05-31 03:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:14:59 UTC to 2016-05-31 04:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:34:59 UTC to 2016-05-31 04:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:54:59 UTC to 2016-05-31 04:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:14:59 UTC to 2016-05-31 05:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:34:59 UTC to 2016-05-31 05:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:54:59 UTC to 2016-05-31 05:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:14:59 UTC to 2016-05-31 06:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:34:59 UTC to 2016-05-31 06:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:54:59 UTC to 2016-05-31 06:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:14:59 UTC to 2016-05-31 07:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:34:59 UTC to 2016-05-31 07:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:54:59 UTC to 2016-05-31 07:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:14:59 UTC to 2016-05-31 08:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:34:59 UTC to 2016-05-31 08:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:54:59 UTC to 2016-05-31 08:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:14:59 UTC to 2016-05-31 09:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:34:59 UTC to 2016-05-31 09:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:54:59 UTC to 2016-05-31 09:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:14:59 UTC to 2016-05-31 10:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:34:59 UTC to 2016-05-31 10:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:54:59 UTC to 2016-05-31 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:14:59 UTC to 2016-05-31 11:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:34:58 UTC to 2016-05-31 11:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:54:59 UTC to 2016-05-31 11:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:14:58 UTC to 2016-05-31 12:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:34:58 UTC to 2016-05-31 12:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:54:58 UTC to 2016-05-31 12:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:14:59 UTC to 2016-05-31 13:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:34:58 UTC to 2016-05-31 13:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:54:58 UTC to 2016-05-31 13:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:14:58 UTC to 2016-05-31 14:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:34:58 UTC to 2016-05-31 14:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:54:58 UTC to 2016-05-31 14:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:14:58 UTC to 2016-05-31 15:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:34:58 UTC to 2016-05-31 15:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:54:58 UTC to 2016-05-31 15:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:14:58 UTC to 2016-05-31 16:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:34:58 UTC to 2016-05-31 16:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:54:58 UTC to 2016-05-31 16:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:14:58 UTC to 2016-05-31 17:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:34:58 UTC to 2016-05-31 17:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:54:58 UTC to 2016-05-31 17:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:14:58 UTC to 2016-05-31 18:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:34:58 UTC to 2016-05-31 18:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:54:58 UTC to 2016-05-31 18:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:14:58 UTC to 2016-05-31 19:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:34:58 UTC to 2016-05-31 19:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:54:58 UTC to 2016-05-31 19:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:14:58 UTC to 2016-05-31 20:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:34:58 UTC to 2016-05-31 20:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:54:58 UTC to 2016-05-31 20:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:14:58 UTC to 2016-05-31 21:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:34:58 UTC to 2016-05-31 21:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:54:58 UTC to 2016-05-31 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:14:58 UTC to 2016-05-31 22:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:34:58 UTC to 2016-05-31 22:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:54:58 UTC to 2016-05-31 22:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 23:34:58 UTC to 2016-05-31 23:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 23:54:58 UTC to 2016-05-31 23:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:14:58 UTC to 2016-06-01 00:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:34:58 UTC to 2016-06-01 00:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:54:58 UTC to 2016-06-01 00:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:14:58 UTC to 2016-06-01 01:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:34:58 UTC to 2016-06-01 01:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:54:58 UTC to 2016-06-01 01:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:14:58 UTC to 2016-06-01 02:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:34:58 UTC to 2016-06-01 02:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:54:58 UTC to 2016-06-01 02:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:14:58 UTC to 2016-06-01 03:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:34:58 UTC to 2016-06-01 03:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:54:58 UTC to 2016-06-01 03:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:14:58 UTC to 2016-06-01 04:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:34:58 UTC to 2016-06-01 04:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:54:58 UTC to 2016-06-01 04:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:14:58 UTC to 2016-06-01 05:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:34:59 UTC to 2016-06-01 05:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:54:58 UTC to 2016-06-01 05:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:14:58 UTC to 2016-06-01 06:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:34:58 UTC to 2016-06-01 06:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:54:58 UTC to 2016-06-01 06:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:15:00 UTC to 2016-06-01 07:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:34:58 UTC to 2016-06-01 07:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:54:58 UTC to 2016-06-01 07:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-05-27 20:45:02 UTC to 2016-05-27 20:45:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 20:55:02 UTC to 2016-05-27 20:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:05:02 UTC to 2016-05-27 21:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:15:15 UTC to 2016-05-27 21:15:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:25:03 UTC to 2016-05-27 21:25:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:35:02 UTC to 2016-05-27 21:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:45:07 UTC to 2016-05-27 21:45:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:55:02 UTC to 2016-05-27 21:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:05:02 UTC to 2016-05-27 22:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:15:02 UTC to 2016-05-27 22:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:25:02 UTC to 2016-05-27 22:25:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:35:02 UTC to 2016-05-27 22:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:45:01 UTC to 2016-05-27 22:45:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:55:12 UTC to 2016-05-27 22:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:05:02 UTC to 2016-05-27 23:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:15:01 UTC to 2016-05-27 23:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:35:02 UTC to 2016-05-27 23:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:55:02 UTC to 2016-05-27 23:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:15:01 UTC to 2016-05-28 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:35:01 UTC to 2016-05-28 00:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:55:01 UTC to 2016-05-28 00:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:15:15 UTC to 2016-05-28 01:15:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:35:01 UTC to 2016-05-28 01:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:55:01 UTC to 2016-05-28 01:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:15:01 UTC to 2016-05-28 02:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:35:01 UTC to 2016-05-28 02:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:55:01 UTC to 2016-05-28 02:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:15:01 UTC to 2016-05-28 03:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:35:01 UTC to 2016-05-28 03:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:55:05 UTC to 2016-05-28 03:55:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:15:01 UTC to 2016-05-28 04:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:35:02 UTC to 2016-05-28 04:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:55:01 UTC to 2016-05-28 04:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:15:02 UTC to 2016-05-28 05:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:35:02 UTC to 2016-05-28 05:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:55:02 UTC to 2016-05-28 05:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:15:01 UTC to 2016-05-28 06:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:35:03 UTC to 2016-05-28 06:35:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:55:01 UTC to 2016-05-28 06:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:15:01 UTC to 2016-05-28 07:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:35:01 UTC to 2016-05-28 07:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:55:01 UTC to 2016-05-28 07:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:15:01 UTC to 2016-05-28 08:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:35:01 UTC to 2016-05-28 08:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:55:01 UTC to 2016-05-28 08:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:15:01 UTC to 2016-05-28 09:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:35:01 UTC to 2016-05-28 09:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:55:01 UTC to 2016-05-28 09:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:15:01 UTC to 2016-05-28 10:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:35:01 UTC to 2016-05-28 10:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:55:01 UTC to 2016-05-28 10:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:15:01 UTC to 2016-05-28 11:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:35:01 UTC to 2016-05-28 11:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:55:01 UTC to 2016-05-28 11:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:15:01 UTC to 2016-05-28 12:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:35:01 UTC to 2016-05-28 12:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:55:01 UTC to 2016-05-28 12:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:15:01 UTC to 2016-05-28 13:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:35:01 UTC to 2016-05-28 13:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:55:01 UTC to 2016-05-28 13:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:15:01 UTC to 2016-05-28 14:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:35:01 UTC to 2016-05-28 14:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:55:01 UTC to 2016-05-28 14:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:15:01 UTC to 2016-05-28 15:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:35:01 UTC to 2016-05-28 15:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:55:26 UTC to 2016-05-28 15:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:15:01 UTC to 2016-05-28 16:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:35:07 UTC to 2016-05-28 16:35:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:55:01 UTC to 2016-05-28 16:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:15:10 UTC to 2016-05-28 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:35:01 UTC to 2016-05-28 17:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:55:01 UTC to 2016-05-28 17:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:15:01 UTC to 2016-05-28 18:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:35:01 UTC to 2016-05-28 18:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:55:03 UTC to 2016-05-28 18:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:15:01 UTC to 2016-05-28 19:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:35:01 UTC to 2016-05-28 19:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:55:01 UTC to 2016-05-28 19:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:15:01 UTC to 2016-05-28 20:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:35:01 UTC to 2016-05-28 20:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:55:01 UTC to 2016-05-28 20:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:15:01 UTC to 2016-05-28 21:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:35:01 UTC to 2016-05-28 21:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:55:01 UTC to 2016-05-28 21:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 22:15:03 UTC to 2016-05-28 22:15:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 22:55:01 UTC to 2016-05-28 22:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:15:44 UTC to 2016-05-28 23:16:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:35:01 UTC to 2016-05-28 23:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:55:03 UTC to 2016-05-28 23:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:15:01 UTC to 2016-05-29 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:35:01 UTC to 2016-05-29 00:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:55:05 UTC to 2016-05-29 00:55:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:15:01 UTC to 2016-05-29 01:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:35:01 UTC to 2016-05-29 01:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:55:01 UTC to 2016-05-29 01:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 02:35:00 UTC to 2016-05-29 02:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 02:55:00 UTC to 2016-05-29 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:15:01 UTC to 2016-05-29 03:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:35:01 UTC to 2016-05-29 03:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:55:00 UTC to 2016-05-29 03:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:15:00 UTC to 2016-05-29 04:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:35:00 UTC to 2016-05-29 04:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:55:01 UTC to 2016-05-29 04:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:15:00 UTC to 2016-05-29 05:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:35:02 UTC to 2016-05-29 05:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:55:00 UTC to 2016-05-29 05:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:15:00 UTC to 2016-05-29 06:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:35:01 UTC to 2016-05-29 06:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:55:00 UTC to 2016-05-29 06:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:15:00 UTC to 2016-05-29 07:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:35:00 UTC to 2016-05-29 07:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:55:00 UTC to 2016-05-29 07:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:15:00 UTC to 2016-05-29 08:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:35:00 UTC to 2016-05-29 08:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:55:27 UTC to 2016-05-29 08:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:15:00 UTC to 2016-05-29 09:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:35:00 UTC to 2016-05-29 09:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:55:00 UTC to 2016-05-29 09:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:15:01 UTC to 2016-05-29 10:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:35:00 UTC to 2016-05-29 10:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:55:00 UTC to 2016-05-29 10:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:15:00 UTC to 2016-05-29 11:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:35:00 UTC to 2016-05-29 11:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:55:01 UTC to 2016-05-29 11:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:15:01 UTC to 2016-05-29 12:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:35:00 UTC to 2016-05-29 12:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:55:00 UTC to 2016-05-29 12:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:15:01 UTC to 2016-05-29 13:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:35:04 UTC to 2016-05-29 13:35:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:55:00 UTC to 2016-05-29 13:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:15:01 UTC to 2016-05-29 14:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:35:02 UTC to 2016-05-29 14:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:55:00 UTC to 2016-05-29 14:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:15:00 UTC to 2016-05-29 15:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:35:00 UTC to 2016-05-29 15:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:55:00 UTC to 2016-05-29 15:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:15:00 UTC to 2016-05-29 16:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:35:00 UTC to 2016-05-29 16:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:56:42 UTC to 2016-05-29 16:57:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:15:00 UTC to 2016-05-29 17:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:35:06 UTC to 2016-05-29 17:35:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:55:00 UTC to 2016-05-29 17:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:15:00 UTC to 2016-05-29 18:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:35:00 UTC to 2016-05-29 18:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:55:01 UTC to 2016-05-29 18:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:15:00 UTC to 2016-05-29 19:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:35:00 UTC to 2016-05-29 19:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:55:00 UTC to 2016-05-29 19:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:15:19 UTC to 2016-05-29 20:15:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:35:04 UTC to 2016-05-29 20:35:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:55:00 UTC to 2016-05-29 20:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:15:00 UTC to 2016-05-29 21:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:35:00 UTC to 2016-05-29 21:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:55:00 UTC to 2016-05-29 21:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:15:00 UTC to 2016-05-29 22:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:35:00 UTC to 2016-05-29 22:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:55:00 UTC to 2016-05-29 22:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:15:11 UTC to 2016-05-29 23:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:35:07 UTC to 2016-05-29 23:35:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:55:00 UTC to 2016-05-29 23:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:15:00 UTC to 2016-05-30 00:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:35:00 UTC to 2016-05-30 00:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:55:00 UTC to 2016-05-30 00:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:15:00 UTC to 2016-05-30 01:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:35:00 UTC to 2016-05-30 01:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:55:00 UTC to 2016-05-30 01:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:15:02 UTC to 2016-05-30 02:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:35:01 UTC to 2016-05-30 02:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:55:00 UTC to 2016-05-30 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:15:00 UTC to 2016-05-30 03:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:35:00 UTC to 2016-05-30 03:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:55:00 UTC to 2016-05-30 03:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:15:00 UTC to 2016-05-30 04:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:35:00 UTC to 2016-05-30 04:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:55:00 UTC to 2016-05-30 04:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:15:00 UTC to 2016-05-30 05:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:35:00 UTC to 2016-05-30 05:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:55:00 UTC to 2016-05-30 05:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:14:59 UTC to 2016-05-30 06:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:34:59 UTC to 2016-05-30 06:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:54:59 UTC to 2016-05-30 06:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:14:59 UTC to 2016-05-30 07:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:34:59 UTC to 2016-05-30 07:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:55:00 UTC to 2016-05-30 07:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:15:00 UTC to 2016-05-30 08:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:35:00 UTC to 2016-05-30 08:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:55:00 UTC to 2016-05-30 08:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:15:00 UTC to 2016-05-30 09:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:35:00 UTC to 2016-05-30 09:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:55:00 UTC to 2016-05-30 09:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:14:59 UTC to 2016-05-30 10:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:34:59 UTC to 2016-05-30 10:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:54:59 UTC to 2016-05-30 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:14:59 UTC to 2016-05-30 11:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:35:00 UTC to 2016-05-30 11:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:54:59 UTC to 2016-05-30 11:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:14:59 UTC to 2016-05-30 12:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:34:59 UTC to 2016-05-30 12:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:54:59 UTC to 2016-05-30 12:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:14:59 UTC to 2016-05-30 13:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:34:59 UTC to 2016-05-30 13:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:54:59 UTC to 2016-05-30 13:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:14:59 UTC to 2016-05-30 14:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:34:59 UTC to 2016-05-30 14:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:54:59 UTC to 2016-05-30 14:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:14:59 UTC to 2016-05-30 15:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:34:59 UTC to 2016-05-30 15:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:54:59 UTC to 2016-05-30 15:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:15:01 UTC to 2016-05-30 16:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:34:59 UTC to 2016-05-30 16:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:55:01 UTC to 2016-05-30 16:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:14:59 UTC to 2016-05-30 17:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:34:59 UTC to 2016-05-30 17:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:55:00 UTC to 2016-05-30 17:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:14:59 UTC to 2016-05-30 18:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:35:06 UTC to 2016-05-30 18:35:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:54:59 UTC to 2016-05-30 18:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:14:59 UTC to 2016-05-30 19:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:34:59 UTC to 2016-05-30 19:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:54:59 UTC to 2016-05-30 19:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:14:59 UTC to 2016-05-30 20:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:34:59 UTC to 2016-05-30 20:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:54:59 UTC to 2016-05-30 20:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:14:59 UTC to 2016-05-30 21:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:34:59 UTC to 2016-05-30 21:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:54:59 UTC to 2016-05-30 21:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:14:59 UTC to 2016-05-30 22:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:34:59 UTC to 2016-05-30 22:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:54:59 UTC to 2016-05-30 22:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:14:59 UTC to 2016-05-30 23:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:34:59 UTC to 2016-05-30 23:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:54:59 UTC to 2016-05-30 23:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:14:59 UTC to 2016-05-31 00:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:34:59 UTC to 2016-05-31 00:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:54:59 UTC to 2016-05-31 00:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:14:59 UTC to 2016-05-31 01:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:34:59 UTC to 2016-05-31 01:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:54:59 UTC to 2016-05-31 01:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:14:59 UTC to 2016-05-31 02:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:34:59 UTC to 2016-05-31 02:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:55:00 UTC to 2016-05-31 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:14:59 UTC to 2016-05-31 03:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:34:59 UTC to 2016-05-31 03:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:54:59 UTC to 2016-05-31 03:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:14:59 UTC to 2016-05-31 04:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:34:59 UTC to 2016-05-31 04:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:54:59 UTC to 2016-05-31 04:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:14:59 UTC to 2016-05-31 05:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:34:59 UTC to 2016-05-31 05:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:54:59 UTC to 2016-05-31 05:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:14:59 UTC to 2016-05-31 06:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:34:59 UTC to 2016-05-31 06:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:54:59 UTC to 2016-05-31 06:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:14:59 UTC to 2016-05-31 07:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:34:59 UTC to 2016-05-31 07:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:54:59 UTC to 2016-05-31 07:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:14:59 UTC to 2016-05-31 08:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:34:59 UTC to 2016-05-31 08:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:54:59 UTC to 2016-05-31 08:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:14:59 UTC to 2016-05-31 09:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:34:59 UTC to 2016-05-31 09:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:54:59 UTC to 2016-05-31 09:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:14:59 UTC to 2016-05-31 10:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:34:59 UTC to 2016-05-31 10:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:54:59 UTC to 2016-05-31 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:14:59 UTC to 2016-05-31 11:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:34:58 UTC to 2016-05-31 11:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:54:59 UTC to 2016-05-31 11:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:14:58 UTC to 2016-05-31 12:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:34:58 UTC to 2016-05-31 12:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:54:58 UTC to 2016-05-31 12:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:14:59 UTC to 2016-05-31 13:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:34:58 UTC to 2016-05-31 13:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:54:58 UTC to 2016-05-31 13:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:14:58 UTC to 2016-05-31 14:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:34:58 UTC to 2016-05-31 14:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:54:58 UTC to 2016-05-31 14:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:14:58 UTC to 2016-05-31 15:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:34:58 UTC to 2016-05-31 15:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:54:58 UTC to 2016-05-31 15:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:14:58 UTC to 2016-05-31 16:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:34:58 UTC to 2016-05-31 16:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:54:58 UTC to 2016-05-31 16:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:14:58 UTC to 2016-05-31 17:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:34:58 UTC to 2016-05-31 17:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:54:58 UTC to 2016-05-31 17:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:14:58 UTC to 2016-05-31 18:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:34:58 UTC to 2016-05-31 18:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:54:58 UTC to 2016-05-31 18:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:14:58 UTC to 2016-05-31 19:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:34:58 UTC to 2016-05-31 19:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:54:58 UTC to 2016-05-31 19:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:14:58 UTC to 2016-05-31 20:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:34:58 UTC to 2016-05-31 20:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:54:58 UTC to 2016-05-31 20:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:14:58 UTC to 2016-05-31 21:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:34:58 UTC to 2016-05-31 21:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:54:58 UTC to 2016-05-31 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:14:58 UTC to 2016-05-31 22:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:34:58 UTC to 2016-05-31 22:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:54:58 UTC to 2016-05-31 22:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 23:34:58 UTC to 2016-05-31 23:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 23:54:58 UTC to 2016-05-31 23:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:14:58 UTC to 2016-06-01 00:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:34:58 UTC to 2016-06-01 00:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:54:58 UTC to 2016-06-01 00:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:14:58 UTC to 2016-06-01 01:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:34:58 UTC to 2016-06-01 01:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:54:58 UTC to 2016-06-01 01:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:14:58 UTC to 2016-06-01 02:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:34:58 UTC to 2016-06-01 02:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:54:58 UTC to 2016-06-01 02:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:14:58 UTC to 2016-06-01 03:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:34:58 UTC to 2016-06-01 03:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:54:58 UTC to 2016-06-01 03:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:14:58 UTC to 2016-06-01 04:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:34:58 UTC to 2016-06-01 04:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:54:58 UTC to 2016-06-01 04:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:14:58 UTC to 2016-06-01 05:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:34:59 UTC to 2016-06-01 05:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:54:58 UTC to 2016-06-01 05:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:14:58 UTC to 2016-06-01 06:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:34:58 UTC to 2016-06-01 06:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:54:58 UTC to 2016-06-01 06:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:15:00 UTC to 2016-06-01 07:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:34:58 UTC to 2016-06-01 07:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:54:58 UTC to 2016-06-01 07:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 20:45:02 UTC to 2016-05-27 20:45:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 20:55:02 UTC to 2016-05-27 20:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:05:02 UTC to 2016-05-27 21:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:15:15 UTC to 2016-05-27 21:15:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:25:03 UTC to 2016-05-27 21:25:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:35:02 UTC to 2016-05-27 21:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:45:07 UTC to 2016-05-27 21:45:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 21:55:02 UTC to 2016-05-27 21:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:05:02 UTC to 2016-05-27 22:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:15:02 UTC to 2016-05-27 22:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:25:02 UTC to 2016-05-27 22:25:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:35:02 UTC to 2016-05-27 22:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:45:01 UTC to 2016-05-27 22:45:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 22:55:12 UTC to 2016-05-27 22:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:05:02 UTC to 2016-05-27 23:05:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:15:01 UTC to 2016-05-27 23:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:35:02 UTC to 2016-05-27 23:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-27 23:55:02 UTC to 2016-05-27 23:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:15:01 UTC to 2016-05-28 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:35:01 UTC to 2016-05-28 00:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 00:55:01 UTC to 2016-05-28 00:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:15:15 UTC to 2016-05-28 01:15:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:35:01 UTC to 2016-05-28 01:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 01:55:01 UTC to 2016-05-28 01:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:15:01 UTC to 2016-05-28 02:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:35:01 UTC to 2016-05-28 02:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 02:55:01 UTC to 2016-05-28 02:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:15:01 UTC to 2016-05-28 03:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:35:01 UTC to 2016-05-28 03:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 03:55:05 UTC to 2016-05-28 03:55:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:15:01 UTC to 2016-05-28 04:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:35:02 UTC to 2016-05-28 04:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 04:55:01 UTC to 2016-05-28 04:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:15:02 UTC to 2016-05-28 05:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:35:02 UTC to 2016-05-28 05:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 05:55:02 UTC to 2016-05-28 05:55:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:15:01 UTC to 2016-05-28 06:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:35:03 UTC to 2016-05-28 06:35:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 06:55:01 UTC to 2016-05-28 06:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:15:01 UTC to 2016-05-28 07:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:35:01 UTC to 2016-05-28 07:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 07:55:01 UTC to 2016-05-28 07:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:15:01 UTC to 2016-05-28 08:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:35:01 UTC to 2016-05-28 08:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 08:55:01 UTC to 2016-05-28 08:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:15:01 UTC to 2016-05-28 09:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:35:01 UTC to 2016-05-28 09:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 09:55:01 UTC to 2016-05-28 09:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:15:01 UTC to 2016-05-28 10:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:35:01 UTC to 2016-05-28 10:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 10:55:01 UTC to 2016-05-28 10:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:15:01 UTC to 2016-05-28 11:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:35:01 UTC to 2016-05-28 11:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 11:55:01 UTC to 2016-05-28 11:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:15:01 UTC to 2016-05-28 12:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:35:01 UTC to 2016-05-28 12:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 12:55:01 UTC to 2016-05-28 12:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:15:01 UTC to 2016-05-28 13:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:35:01 UTC to 2016-05-28 13:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 13:55:01 UTC to 2016-05-28 13:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:15:01 UTC to 2016-05-28 14:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:35:01 UTC to 2016-05-28 14:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 14:55:01 UTC to 2016-05-28 14:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:15:01 UTC to 2016-05-28 15:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:35:01 UTC to 2016-05-28 15:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 15:55:26 UTC to 2016-05-28 15:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:15:01 UTC to 2016-05-28 16:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:35:07 UTC to 2016-05-28 16:35:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 16:55:01 UTC to 2016-05-28 16:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:15:10 UTC to 2016-05-28 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:35:01 UTC to 2016-05-28 17:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 17:55:01 UTC to 2016-05-28 17:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:15:01 UTC to 2016-05-28 18:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:35:01 UTC to 2016-05-28 18:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 18:55:03 UTC to 2016-05-28 18:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:15:01 UTC to 2016-05-28 19:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:35:01 UTC to 2016-05-28 19:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 19:55:01 UTC to 2016-05-28 19:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:15:01 UTC to 2016-05-28 20:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:35:01 UTC to 2016-05-28 20:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 20:55:01 UTC to 2016-05-28 20:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:15:01 UTC to 2016-05-28 21:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:35:01 UTC to 2016-05-28 21:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 21:55:01 UTC to 2016-05-28 21:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 22:15:03 UTC to 2016-05-28 22:15:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 22:55:01 UTC to 2016-05-28 22:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:15:44 UTC to 2016-05-28 23:16:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:35:01 UTC to 2016-05-28 23:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-28 23:55:03 UTC to 2016-05-28 23:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:15:01 UTC to 2016-05-29 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:35:01 UTC to 2016-05-29 00:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 00:55:05 UTC to 2016-05-29 00:55:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:15:01 UTC to 2016-05-29 01:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:35:01 UTC to 2016-05-29 01:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 01:55:01 UTC to 2016-05-29 01:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 02:35:00 UTC to 2016-05-29 02:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 02:55:00 UTC to 2016-05-29 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:15:01 UTC to 2016-05-29 03:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:35:01 UTC to 2016-05-29 03:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 03:55:00 UTC to 2016-05-29 03:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:15:00 UTC to 2016-05-29 04:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:35:00 UTC to 2016-05-29 04:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 04:55:01 UTC to 2016-05-29 04:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:15:00 UTC to 2016-05-29 05:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:35:02 UTC to 2016-05-29 05:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 05:55:00 UTC to 2016-05-29 05:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:15:00 UTC to 2016-05-29 06:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:35:01 UTC to 2016-05-29 06:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 06:55:00 UTC to 2016-05-29 06:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:15:00 UTC to 2016-05-29 07:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:35:00 UTC to 2016-05-29 07:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 07:55:00 UTC to 2016-05-29 07:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:15:00 UTC to 2016-05-29 08:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:35:00 UTC to 2016-05-29 08:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 08:55:27 UTC to 2016-05-29 08:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:15:00 UTC to 2016-05-29 09:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:35:00 UTC to 2016-05-29 09:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 09:55:00 UTC to 2016-05-29 09:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:15:01 UTC to 2016-05-29 10:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:35:00 UTC to 2016-05-29 10:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 10:55:00 UTC to 2016-05-29 10:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:15:00 UTC to 2016-05-29 11:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:35:00 UTC to 2016-05-29 11:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 11:55:01 UTC to 2016-05-29 11:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:15:01 UTC to 2016-05-29 12:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:35:00 UTC to 2016-05-29 12:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 12:55:00 UTC to 2016-05-29 12:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:15:01 UTC to 2016-05-29 13:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:35:04 UTC to 2016-05-29 13:35:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 13:55:00 UTC to 2016-05-29 13:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:15:01 UTC to 2016-05-29 14:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:35:02 UTC to 2016-05-29 14:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 14:55:00 UTC to 2016-05-29 14:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:15:00 UTC to 2016-05-29 15:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:35:00 UTC to 2016-05-29 15:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 15:55:00 UTC to 2016-05-29 15:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:15:00 UTC to 2016-05-29 16:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:35:00 UTC to 2016-05-29 16:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 16:56:42 UTC to 2016-05-29 16:57:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:15:00 UTC to 2016-05-29 17:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:35:06 UTC to 2016-05-29 17:35:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 17:55:00 UTC to 2016-05-29 17:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:15:00 UTC to 2016-05-29 18:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:35:00 UTC to 2016-05-29 18:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 18:55:01 UTC to 2016-05-29 18:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:15:00 UTC to 2016-05-29 19:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:35:00 UTC to 2016-05-29 19:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 19:55:00 UTC to 2016-05-29 19:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:15:19 UTC to 2016-05-29 20:15:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:35:04 UTC to 2016-05-29 20:35:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 20:55:00 UTC to 2016-05-29 20:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:15:00 UTC to 2016-05-29 21:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:35:00 UTC to 2016-05-29 21:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 21:55:00 UTC to 2016-05-29 21:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:15:00 UTC to 2016-05-29 22:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:35:00 UTC to 2016-05-29 22:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 22:55:00 UTC to 2016-05-29 22:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:15:11 UTC to 2016-05-29 23:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:35:07 UTC to 2016-05-29 23:35:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-29 23:55:00 UTC to 2016-05-29 23:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:15:00 UTC to 2016-05-30 00:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:35:00 UTC to 2016-05-30 00:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 00:55:00 UTC to 2016-05-30 00:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:15:00 UTC to 2016-05-30 01:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:35:00 UTC to 2016-05-30 01:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 01:55:00 UTC to 2016-05-30 01:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:15:02 UTC to 2016-05-30 02:15:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:35:01 UTC to 2016-05-30 02:35:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 02:55:00 UTC to 2016-05-30 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:15:00 UTC to 2016-05-30 03:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:35:00 UTC to 2016-05-30 03:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 03:55:00 UTC to 2016-05-30 03:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:15:00 UTC to 2016-05-30 04:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:35:00 UTC to 2016-05-30 04:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 04:55:00 UTC to 2016-05-30 04:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:15:00 UTC to 2016-05-30 05:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:35:00 UTC to 2016-05-30 05:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 05:55:00 UTC to 2016-05-30 05:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:14:59 UTC to 2016-05-30 06:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:34:59 UTC to 2016-05-30 06:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 06:54:59 UTC to 2016-05-30 06:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:14:59 UTC to 2016-05-30 07:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:34:59 UTC to 2016-05-30 07:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 07:55:00 UTC to 2016-05-30 07:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:15:00 UTC to 2016-05-30 08:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:35:00 UTC to 2016-05-30 08:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 08:55:00 UTC to 2016-05-30 08:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:15:00 UTC to 2016-05-30 09:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:35:00 UTC to 2016-05-30 09:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 09:55:00 UTC to 2016-05-30 09:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:14:59 UTC to 2016-05-30 10:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:34:59 UTC to 2016-05-30 10:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 10:54:59 UTC to 2016-05-30 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:14:59 UTC to 2016-05-30 11:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:35:00 UTC to 2016-05-30 11:35:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 11:54:59 UTC to 2016-05-30 11:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:14:59 UTC to 2016-05-30 12:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:34:59 UTC to 2016-05-30 12:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 12:54:59 UTC to 2016-05-30 12:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:14:59 UTC to 2016-05-30 13:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:34:59 UTC to 2016-05-30 13:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 13:54:59 UTC to 2016-05-30 13:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:14:59 UTC to 2016-05-30 14:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:34:59 UTC to 2016-05-30 14:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 14:54:59 UTC to 2016-05-30 14:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:14:59 UTC to 2016-05-30 15:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:34:59 UTC to 2016-05-30 15:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 15:54:59 UTC to 2016-05-30 15:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:15:01 UTC to 2016-05-30 16:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:34:59 UTC to 2016-05-30 16:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 16:55:01 UTC to 2016-05-30 16:55:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:14:59 UTC to 2016-05-30 17:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:34:59 UTC to 2016-05-30 17:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 17:55:00 UTC to 2016-05-30 17:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:14:59 UTC to 2016-05-30 18:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:35:06 UTC to 2016-05-30 18:35:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 18:54:59 UTC to 2016-05-30 18:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:14:59 UTC to 2016-05-30 19:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:34:59 UTC to 2016-05-30 19:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 19:54:59 UTC to 2016-05-30 19:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:14:59 UTC to 2016-05-30 20:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:34:59 UTC to 2016-05-30 20:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 20:54:59 UTC to 2016-05-30 20:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:14:59 UTC to 2016-05-30 21:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:34:59 UTC to 2016-05-30 21:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 21:54:59 UTC to 2016-05-30 21:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:14:59 UTC to 2016-05-30 22:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:34:59 UTC to 2016-05-30 22:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 22:54:59 UTC to 2016-05-30 22:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:14:59 UTC to 2016-05-30 23:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:34:59 UTC to 2016-05-30 23:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-30 23:54:59 UTC to 2016-05-30 23:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:14:59 UTC to 2016-05-31 00:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:34:59 UTC to 2016-05-31 00:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 00:54:59 UTC to 2016-05-31 00:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:14:59 UTC to 2016-05-31 01:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:34:59 UTC to 2016-05-31 01:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 01:54:59 UTC to 2016-05-31 01:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:14:59 UTC to 2016-05-31 02:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:34:59 UTC to 2016-05-31 02:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 02:55:00 UTC to 2016-05-31 02:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:14:59 UTC to 2016-05-31 03:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:34:59 UTC to 2016-05-31 03:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 03:54:59 UTC to 2016-05-31 03:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:14:59 UTC to 2016-05-31 04:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:34:59 UTC to 2016-05-31 04:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 04:54:59 UTC to 2016-05-31 04:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:14:59 UTC to 2016-05-31 05:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:34:59 UTC to 2016-05-31 05:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 05:54:59 UTC to 2016-05-31 05:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:14:59 UTC to 2016-05-31 06:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:34:59 UTC to 2016-05-31 06:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 06:54:59 UTC to 2016-05-31 06:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:14:59 UTC to 2016-05-31 07:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:34:59 UTC to 2016-05-31 07:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 07:54:59 UTC to 2016-05-31 07:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:14:59 UTC to 2016-05-31 08:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:34:59 UTC to 2016-05-31 08:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 08:54:59 UTC to 2016-05-31 08:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:14:59 UTC to 2016-05-31 09:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:34:59 UTC to 2016-05-31 09:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 09:54:59 UTC to 2016-05-31 09:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:14:59 UTC to 2016-05-31 10:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:34:59 UTC to 2016-05-31 10:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 10:54:59 UTC to 2016-05-31 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:14:59 UTC to 2016-05-31 11:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:34:58 UTC to 2016-05-31 11:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 11:54:59 UTC to 2016-05-31 11:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:14:58 UTC to 2016-05-31 12:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:34:58 UTC to 2016-05-31 12:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 12:54:58 UTC to 2016-05-31 12:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:14:59 UTC to 2016-05-31 13:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:34:58 UTC to 2016-05-31 13:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 13:54:58 UTC to 2016-05-31 13:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:14:58 UTC to 2016-05-31 14:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:34:58 UTC to 2016-05-31 14:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 14:54:58 UTC to 2016-05-31 14:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:14:58 UTC to 2016-05-31 15:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:34:58 UTC to 2016-05-31 15:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 15:54:58 UTC to 2016-05-31 15:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:14:58 UTC to 2016-05-31 16:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:34:58 UTC to 2016-05-31 16:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 16:54:58 UTC to 2016-05-31 16:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:14:58 UTC to 2016-05-31 17:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:34:58 UTC to 2016-05-31 17:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 17:54:58 UTC to 2016-05-31 17:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:14:58 UTC to 2016-05-31 18:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:34:58 UTC to 2016-05-31 18:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 18:54:58 UTC to 2016-05-31 18:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:14:58 UTC to 2016-05-31 19:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:34:58 UTC to 2016-05-31 19:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 19:54:58 UTC to 2016-05-31 19:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:14:58 UTC to 2016-05-31 20:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:34:58 UTC to 2016-05-31 20:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 20:54:58 UTC to 2016-05-31 20:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:14:58 UTC to 2016-05-31 21:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:34:58 UTC to 2016-05-31 21:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 21:54:58 UTC to 2016-05-31 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:14:58 UTC to 2016-05-31 22:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:34:58 UTC to 2016-05-31 22:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 22:54:58 UTC to 2016-05-31 22:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 23:34:58 UTC to 2016-05-31 23:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-05-31 23:54:58 UTC to 2016-05-31 23:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:14:58 UTC to 2016-06-01 00:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:34:58 UTC to 2016-06-01 00:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 00:54:58 UTC to 2016-06-01 00:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:14:58 UTC to 2016-06-01 01:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:34:58 UTC to 2016-06-01 01:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 01:54:58 UTC to 2016-06-01 01:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:14:58 UTC to 2016-06-01 02:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:34:58 UTC to 2016-06-01 02:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 02:54:58 UTC to 2016-06-01 02:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:14:58 UTC to 2016-06-01 03:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:34:58 UTC to 2016-06-01 03:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 03:54:58 UTC to 2016-06-01 03:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:14:58 UTC to 2016-06-01 04:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:34:58 UTC to 2016-06-01 04:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 04:54:58 UTC to 2016-06-01 04:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:14:58 UTC to 2016-06-01 05:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:34:59 UTC to 2016-06-01 05:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 05:54:58 UTC to 2016-06-01 05:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:14:58 UTC to 2016-06-01 06:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:34:58 UTC to 2016-06-01 06:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 06:54:58 UTC to 2016-06-01 06:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:15:00 UTC to 2016-06-01 07:15:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:34:58 UTC to 2016-06-01 07:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 07:54:58 UTC to 2016-06-01 07:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-01 08:14:58 UTC to 2016-06-01 08:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 08:35:02 UTC to 2016-06-01 08:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 08:54:58 UTC to 2016-06-01 08:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:14:58 UTC to 2016-06-01 09:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:34:58 UTC to 2016-06-01 09:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:54:58 UTC to 2016-06-01 09:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:14:58 UTC to 2016-06-01 10:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:34:58 UTC to 2016-06-01 10:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:54:58 UTC to 2016-06-01 10:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:14:58 UTC to 2016-06-01 11:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:34:58 UTC to 2016-06-01 11:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:54:58 UTC to 2016-06-01 11:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:14:58 UTC to 2016-06-01 12:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:34:58 UTC to 2016-06-01 12:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:54:58 UTC to 2016-06-01 12:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:14:57 UTC to 2016-06-01 13:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:34:58 UTC to 2016-06-01 13:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:54:58 UTC to 2016-06-01 13:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:14:57 UTC to 2016-06-01 14:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:34:57 UTC to 2016-06-01 14:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:54:57 UTC to 2016-06-01 14:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:14:59 UTC to 2016-06-01 15:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:34:57 UTC to 2016-06-01 15:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:54:57 UTC to 2016-06-01 15:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:14:59 UTC to 2016-06-01 16:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:34:58 UTC to 2016-06-01 16:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:54:57 UTC to 2016-06-01 16:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:14:57 UTC to 2016-06-01 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:34:57 UTC to 2016-06-01 17:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:54:57 UTC to 2016-06-01 17:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:14:58 UTC to 2016-06-01 18:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:34:57 UTC to 2016-06-01 18:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:54:57 UTC to 2016-06-01 18:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:14:57 UTC to 2016-06-01 19:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:34:57 UTC to 2016-06-01 19:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:54:57 UTC to 2016-06-01 19:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:14:58 UTC to 2016-06-01 20:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:34:57 UTC to 2016-06-01 20:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:54:57 UTC to 2016-06-01 20:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:14:57 UTC to 2016-06-01 21:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:34:58 UTC to 2016-06-01 21:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:54:58 UTC to 2016-06-01 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:14:58 UTC to 2016-06-01 22:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:34:57 UTC to 2016-06-01 22:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:55:00 UTC to 2016-06-01 22:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:14:57 UTC to 2016-06-01 23:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:34:57 UTC to 2016-06-01 23:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:54:57 UTC to 2016-06-01 23:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:14:57 UTC to 2016-06-02 00:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:34:57 UTC to 2016-06-02 00:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:54:57 UTC to 2016-06-02 00:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:14:57 UTC to 2016-06-02 01:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:34:57 UTC to 2016-06-02 01:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:55:00 UTC to 2016-06-02 01:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:14:57 UTC to 2016-06-02 02:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:34:57 UTC to 2016-06-02 02:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:54:57 UTC to 2016-06-02 02:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:14:57 UTC to 2016-06-02 03:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:34:57 UTC to 2016-06-02 03:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:54:57 UTC to 2016-06-02 03:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:14:57 UTC to 2016-06-02 04:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:34:57 UTC to 2016-06-02 04:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:54:57 UTC to 2016-06-02 04:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:14:57 UTC to 2016-06-02 05:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:34:57 UTC to 2016-06-02 05:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:54:57 UTC to 2016-06-02 05:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:14:57 UTC to 2016-06-02 06:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:34:57 UTC to 2016-06-02 06:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:54:57 UTC to 2016-06-02 06:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:14:57 UTC to 2016-06-02 07:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:34:57 UTC to 2016-06-02 07:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:54:57 UTC to 2016-06-02 07:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:14:57 UTC to 2016-06-02 08:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:34:57 UTC to 2016-06-02 08:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:54:57 UTC to 2016-06-02 08:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:14:57 UTC to 2016-06-02 09:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:34:57 UTC to 2016-06-02 09:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:54:57 UTC to 2016-06-02 09:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:14:57 UTC to 2016-06-02 10:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:34:57 UTC to 2016-06-02 10:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:54:57 UTC to 2016-06-02 10:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:14:57 UTC to 2016-06-02 11:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:34:57 UTC to 2016-06-02 11:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:54:57 UTC to 2016-06-02 11:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:14:57 UTC to 2016-06-02 12:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:34:57 UTC to 2016-06-02 12:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:54:57 UTC to 2016-06-02 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:15:04 UTC to 2016-06-02 13:15:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:34:57 UTC to 2016-06-02 13:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:54:57 UTC to 2016-06-02 13:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:14:57 UTC to 2016-06-02 14:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:34:57 UTC to 2016-06-02 14:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:54:57 UTC to 2016-06-02 14:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:14:57 UTC to 2016-06-02 15:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:34:57 UTC to 2016-06-02 15:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:54:56 UTC to 2016-06-02 15:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:14:56 UTC to 2016-06-02 16:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:34:56 UTC to 2016-06-02 16:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:54:56 UTC to 2016-06-02 16:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:14:57 UTC to 2016-06-02 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:34:57 UTC to 2016-06-02 17:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:54:57 UTC to 2016-06-02 17:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:14:56 UTC to 2016-06-02 18:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:34:57 UTC to 2016-06-02 18:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:54:56 UTC to 2016-06-02 18:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:14:57 UTC to 2016-06-02 19:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:34:57 UTC to 2016-06-02 19:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:54:56 UTC to 2016-06-02 19:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 20:34:56 UTC to 2016-06-02 20:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 20:54:56 UTC to 2016-06-02 20:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:14:58 UTC to 2016-06-02 21:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:34:56 UTC to 2016-06-02 21:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:54:56 UTC to 2016-06-02 21:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:14:59 UTC to 2016-06-02 22:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:34:57 UTC to 2016-06-02 22:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:54:56 UTC to 2016-06-02 22:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:14:56 UTC to 2016-06-02 23:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:34:56 UTC to 2016-06-02 23:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:54:56 UTC to 2016-06-02 23:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:14:56 UTC to 2016-06-03 00:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:34:56 UTC to 2016-06-03 00:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:54:56 UTC to 2016-06-03 00:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:14:57 UTC to 2016-06-03 01:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:34:56 UTC to 2016-06-03 01:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:54:56 UTC to 2016-06-03 01:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:14:56 UTC to 2016-06-03 02:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:34:56 UTC to 2016-06-03 02:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:54:56 UTC to 2016-06-03 02:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:14:56 UTC to 2016-06-03 03:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:34:56 UTC to 2016-06-03 03:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:54:56 UTC to 2016-06-03 03:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:14:56 UTC to 2016-06-03 04:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:34:56 UTC to 2016-06-03 04:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:54:56 UTC to 2016-06-03 04:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:14:56 UTC to 2016-06-03 05:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:34:58 UTC to 2016-06-03 05:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:54:56 UTC to 2016-06-03 05:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:14:56 UTC to 2016-06-03 06:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:34:56 UTC to 2016-06-03 06:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:54:56 UTC to 2016-06-03 06:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:14:56 UTC to 2016-06-03 07:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:34:56 UTC to 2016-06-03 07:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:54:56 UTC to 2016-06-03 07:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:14:56 UTC to 2016-06-03 08:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:34:56 UTC to 2016-06-03 08:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:54:56 UTC to 2016-06-03 08:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:14:56 UTC to 2016-06-03 09:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:34:56 UTC to 2016-06-03 09:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:54:56 UTC to 2016-06-03 09:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:14:56 UTC to 2016-06-03 10:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:34:56 UTC to 2016-06-03 10:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:54:56 UTC to 2016-06-03 10:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:14:56 UTC to 2016-06-03 11:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:34:56 UTC to 2016-06-03 11:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:54:56 UTC to 2016-06-03 11:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:14:56 UTC to 2016-06-03 12:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:34:56 UTC to 2016-06-03 12:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:55:14 UTC to 2016-06-03 12:55:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:14:56 UTC to 2016-06-03 13:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:34:56 UTC to 2016-06-03 13:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:54:56 UTC to 2016-06-03 13:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 14:34:56 UTC to 2016-06-03 14:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 14:54:56 UTC to 2016-06-03 14:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:14:56 UTC to 2016-06-03 15:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:34:56 UTC to 2016-06-03 15:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:54:56 UTC to 2016-06-03 15:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:14:56 UTC to 2016-06-03 16:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:34:56 UTC to 2016-06-03 16:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:54:56 UTC to 2016-06-03 16:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:14:57 UTC to 2016-06-03 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:35:03 UTC to 2016-06-03 17:35:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:54:56 UTC to 2016-06-03 17:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:14:56 UTC to 2016-06-03 18:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:34:56 UTC to 2016-06-03 18:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:54:56 UTC to 2016-06-03 18:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:14:56 UTC to 2016-06-03 19:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:34:56 UTC to 2016-06-03 19:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:54:56 UTC to 2016-06-03 19:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:14:56 UTC to 2016-06-03 20:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:34:56 UTC to 2016-06-03 20:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:54:55 UTC to 2016-06-03 20:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:14:55 UTC to 2016-06-03 21:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:34:55 UTC to 2016-06-03 21:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:54:58 UTC to 2016-06-03 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:14:56 UTC to 2016-06-03 22:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:34:59 UTC to 2016-06-03 22:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:54:55 UTC to 2016-06-03 22:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:14:55 UTC to 2016-06-03 23:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:34:55 UTC to 2016-06-03 23:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:54:56 UTC to 2016-06-03 23:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:14:55 UTC to 2016-06-04 00:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:34:55 UTC to 2016-06-04 00:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:54:56 UTC to 2016-06-04 00:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:14:55 UTC to 2016-06-04 01:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:34:56 UTC to 2016-06-04 01:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:54:56 UTC to 2016-06-04 01:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:14:55 UTC to 2016-06-04 02:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:34:56 UTC to 2016-06-04 02:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:54:55 UTC to 2016-06-04 02:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:14:55 UTC to 2016-06-04 03:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:34:55 UTC to 2016-06-04 03:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:54:56 UTC to 2016-06-04 03:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:14:55 UTC to 2016-06-04 04:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:34:55 UTC to 2016-06-04 04:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:54:55 UTC to 2016-06-04 04:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:14:55 UTC to 2016-06-04 05:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:34:55 UTC to 2016-06-04 05:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:54:55 UTC to 2016-06-04 05:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:14:55 UTC to 2016-06-04 06:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:34:55 UTC to 2016-06-04 06:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:54:55 UTC to 2016-06-04 06:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:14:55 UTC to 2016-06-04 07:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:34:55 UTC to 2016-06-04 07:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:54:57 UTC to 2016-06-04 07:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:14:55 UTC to 2016-06-04 08:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:34:55 UTC to 2016-06-04 08:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:54:55 UTC to 2016-06-04 08:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:14:55 UTC to 2016-06-04 09:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:34:55 UTC to 2016-06-04 09:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:54:55 UTC to 2016-06-04 09:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:14:55 UTC to 2016-06-04 10:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:34:55 UTC to 2016-06-04 10:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:54:55 UTC to 2016-06-04 10:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:14:55 UTC to 2016-06-04 11:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:34:55 UTC to 2016-06-04 11:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:54:55 UTC to 2016-06-04 11:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:14:55 UTC to 2016-06-04 12:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:34:55 UTC to 2016-06-04 12:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:54:55 UTC to 2016-06-04 12:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:14:55 UTC to 2016-06-04 13:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:34:55 UTC to 2016-06-04 13:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:54:55 UTC to 2016-06-04 13:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:14:55 UTC to 2016-06-04 14:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:34:55 UTC to 2016-06-04 14:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:54:55 UTC to 2016-06-04 14:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:14:55 UTC to 2016-06-04 15:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:34:55 UTC to 2016-06-04 15:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:54:55 UTC to 2016-06-04 15:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:14:55 UTC to 2016-06-04 16:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:34:55 UTC to 2016-06-04 16:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:54:55 UTC to 2016-06-04 16:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:14:55 UTC to 2016-06-04 17:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:34:55 UTC to 2016-06-04 17:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:54:55 UTC to 2016-06-04 17:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:14:55 UTC to 2016-06-04 18:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:34:55 UTC to 2016-06-04 18:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:54:57 UTC to 2016-06-04 18:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:14:55 UTC to 2016-06-04 19:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:34:55 UTC to 2016-06-04 19:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:54:55 UTC to 2016-06-04 19:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:14:55 UTC to 2016-06-04 20:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:34:55 UTC to 2016-06-04 20:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:54:55 UTC to 2016-06-04 20:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:14:55 UTC to 2016-06-04 21:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:35:05 UTC to 2016-06-04 21:35:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:54:55 UTC to 2016-06-04 21:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:14:55 UTC to 2016-06-04 22:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:34:55 UTC to 2016-06-04 22:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:54:54 UTC to 2016-06-04 22:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:14:54 UTC to 2016-06-04 23:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:34:55 UTC to 2016-06-04 23:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:54:55 UTC to 2016-06-04 23:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:14:55 UTC to 2016-06-05 00:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:34:54 UTC to 2016-06-05 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:54:54 UTC to 2016-06-05 00:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:14:55 UTC to 2016-06-05 01:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:34:54 UTC to 2016-06-05 01:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:54:55 UTC to 2016-06-05 01:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:14:54 UTC to 2016-06-05 02:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:34:54 UTC to 2016-06-05 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:54:54 UTC to 2016-06-05 02:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:14:54 UTC to 2016-06-05 03:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:34:55 UTC to 2016-06-05 03:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:54:54 UTC to 2016-06-05 03:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:14:54 UTC to 2016-06-05 04:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:34:55 UTC to 2016-06-05 04:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:54:54 UTC to 2016-06-05 04:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:14:54 UTC to 2016-06-05 05:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:34:54 UTC to 2016-06-05 05:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:54:54 UTC to 2016-06-05 05:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:14:54 UTC to 2016-06-05 06:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:34:54 UTC to 2016-06-05 06:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:54:55 UTC to 2016-06-05 06:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 07:14:54 UTC to 2016-06-05 07:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 07:34:54 UTC to 2016-06-05 07:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:14:54 UTC to 2016-06-05 08:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:34:54 UTC to 2016-06-05 08:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:54:54 UTC to 2016-06-05 08:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:14:54 UTC to 2016-06-05 09:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:34:55 UTC to 2016-06-05 09:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:54:54 UTC to 2016-06-05 09:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:14:54 UTC to 2016-06-05 10:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:34:55 UTC to 2016-06-05 10:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:54:59 UTC to 2016-06-05 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:14:54 UTC to 2016-06-05 11:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:34:54 UTC to 2016-06-05 11:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:54:54 UTC to 2016-06-05 11:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:14:54 UTC to 2016-06-05 12:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:34:54 UTC to 2016-06-05 12:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:54:57 UTC to 2016-06-05 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 13:14:54 UTC to 2016-06-05 13:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 13:54:54 UTC to 2016-06-05 13:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:14:54 UTC to 2016-06-05 14:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:34:54 UTC to 2016-06-05 14:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:54:54 UTC to 2016-06-05 14:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:14:54 UTC to 2016-06-05 15:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:34:54 UTC to 2016-06-05 15:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:54:54 UTC to 2016-06-05 15:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:14:54 UTC to 2016-06-05 16:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:34:54 UTC to 2016-06-05 16:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:54:54 UTC to 2016-06-05 16:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:14:54 UTC to 2016-06-05 17:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:34:54 UTC to 2016-06-05 17:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:54:54 UTC to 2016-06-05 17:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:14:54 UTC to 2016-06-05 18:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:34:54 UTC to 2016-06-05 18:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:54:54 UTC to 2016-06-05 18:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:14:54 UTC to 2016-06-05 19:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:34:54 UTC to 2016-06-05 19:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:54:54 UTC to 2016-06-05 19:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:14:54 UTC to 2016-06-05 20:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:34:54 UTC to 2016-06-05 20:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:54:54 UTC to 2016-06-05 20:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:14:54 UTC to 2016-06-05 21:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:34:54 UTC to 2016-06-05 21:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:54:54 UTC to 2016-06-05 21:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:14:54 UTC to 2016-06-05 22:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:34:54 UTC to 2016-06-05 22:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:54:54 UTC to 2016-06-05 22:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:14:54 UTC to 2016-06-05 23:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:34:54 UTC to 2016-06-05 23:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:54:54 UTC to 2016-06-05 23:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:14:54 UTC to 2016-06-06 00:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:34:54 UTC to 2016-06-06 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:54:54 UTC to 2016-06-06 00:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:14:54 UTC to 2016-06-06 01:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:34:54 UTC to 2016-06-06 01:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:54:54 UTC to 2016-06-06 01:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:14:53 UTC to 2016-06-06 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:34:54 UTC to 2016-06-06 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:54:54 UTC to 2016-06-06 02:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 03:14:54 UTC to 2016-06-06 03:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 03:54:54 UTC to 2016-06-06 03:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:14:53 UTC to 2016-06-06 04:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:34:53 UTC to 2016-06-06 04:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:54:53 UTC to 2016-06-06 04:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:14:53 UTC to 2016-06-06 05:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:34:53 UTC to 2016-06-06 05:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:54:53 UTC to 2016-06-06 05:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:14:53 UTC to 2016-06-06 06:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:34:53 UTC to 2016-06-06 06:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:54:53 UTC to 2016-06-06 06:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:14:53 UTC to 2016-06-06 07:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:34:53 UTC to 2016-06-06 07:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:54:53 UTC to 2016-06-06 07:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:14:53 UTC to 2016-06-06 08:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:34:53 UTC to 2016-06-06 08:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:54:53 UTC to 2016-06-06 08:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:14:55 UTC to 2016-06-06 09:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:34:53 UTC to 2016-06-06 09:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:54:53 UTC to 2016-06-06 09:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:14:53 UTC to 2016-06-06 10:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:34:53 UTC to 2016-06-06 10:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:54:53 UTC to 2016-06-06 10:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:14:54 UTC to 2016-06-06 11:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:34:53 UTC to 2016-06-06 11:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:54:53 UTC to 2016-06-06 11:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:14:53 UTC to 2016-06-06 12:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:34:53 UTC to 2016-06-06 12:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:54:54 UTC to 2016-06-06 12:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:14:53 UTC to 2016-06-06 13:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:34:53 UTC to 2016-06-06 13:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:54:53 UTC to 2016-06-06 13:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:14:53 UTC to 2016-06-06 14:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:34:53 UTC to 2016-06-06 14:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:54:53 UTC to 2016-06-06 14:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:14:53 UTC to 2016-06-06 15:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:34:53 UTC to 2016-06-06 15:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:54:53 UTC to 2016-06-06 15:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:14:53 UTC to 2016-06-06 16:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:34:53 UTC to 2016-06-06 16:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:54:53 UTC to 2016-06-06 16:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:14:53 UTC to 2016-06-06 17:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:34:53 UTC to 2016-06-06 17:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:54:53 UTC to 2016-06-06 17:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:14:53 UTC to 2016-06-06 18:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:34:53 UTC to 2016-06-06 18:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:54:53 UTC to 2016-06-06 18:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:14:53 UTC to 2016-06-06 19:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:34:53 UTC to 2016-06-06 19:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:54:53 UTC to 2016-06-06 19:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:14:53 UTC to 2016-06-06 20:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:34:53 UTC to 2016-06-06 20:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:54:53 UTC to 2016-06-06 20:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:14:53 UTC to 2016-06-06 21:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:34:53 UTC to 2016-06-06 21:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:54:53 UTC to 2016-06-06 21:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 22:14:53 UTC to 2016-06-06 22:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 22:35:05 UTC to 2016-06-06 22:35:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:15:01 UTC to 2016-06-07 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:34:56 UTC to 2016-06-07 00:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:54:57 UTC to 2016-06-07 00:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 01:34:53 UTC to 2016-06-07 01:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 01:54:55 UTC to 2016-06-07 01:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:14:53 UTC to 2016-06-07 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:34:53 UTC to 2016-06-07 02:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:54:53 UTC to 2016-06-07 02:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:14:53 UTC to 2016-06-07 03:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:34:53 UTC to 2016-06-07 03:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:54:53 UTC to 2016-06-07 03:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:14:52 UTC to 2016-06-07 04:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:34:53 UTC to 2016-06-07 04:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:54:53 UTC to 2016-06-07 04:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:14:52 UTC to 2016-06-07 05:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:34:53 UTC to 2016-06-07 05:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:54:52 UTC to 2016-06-07 05:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:14:52 UTC to 2016-06-07 06:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:34:52 UTC to 2016-06-07 06:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:54:52 UTC to 2016-06-07 06:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:14:52 UTC to 2016-06-07 07:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:34:52 UTC to 2016-06-07 07:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:54:52 UTC to 2016-06-07 07:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:14:52 UTC to 2016-06-07 08:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:34:52 UTC to 2016-06-07 08:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:54:52 UTC to 2016-06-07 08:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:14:52 UTC to 2016-06-07 09:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:34:52 UTC to 2016-06-07 09:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:54:52 UTC to 2016-06-07 09:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:14:52 UTC to 2016-06-07 10:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:34:52 UTC to 2016-06-07 10:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:54:53 UTC to 2016-06-07 10:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:14:52 UTC to 2016-06-07 11:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:34:52 UTC to 2016-06-07 11:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:54:52 UTC to 2016-06-07 11:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:14:52 UTC to 2016-06-07 12:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:34:52 UTC to 2016-06-07 12:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:54:57 UTC to 2016-06-07 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:14:52 UTC to 2016-06-07 13:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:34:52 UTC to 2016-06-07 13:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:54:52 UTC to 2016-06-07 13:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:14:52 UTC to 2016-06-07 14:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:34:52 UTC to 2016-06-07 14:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:54:52 UTC to 2016-06-07 14:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:14:53 UTC to 2016-06-07 15:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:34:52 UTC to 2016-06-07 15:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:54:52 UTC to 2016-06-07 15:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:14:52 UTC to 2016-06-07 16:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:34:53 UTC to 2016-06-07 16:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:54:52 UTC to 2016-06-07 16:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:14:52 UTC to 2016-06-07 17:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:36:08 UTC to 2016-06-07 17:36:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:54:52 UTC to 2016-06-07 17:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:14:52 UTC to 2016-06-07 18:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:34:52 UTC to 2016-06-07 18:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:54:53 UTC to 2016-06-07 18:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:14:52 UTC to 2016-06-07 19:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:34:52 UTC to 2016-06-07 19:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:54:52 UTC to 2016-06-07 19:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:14:52 UTC to 2016-06-07 20:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:34:52 UTC to 2016-06-07 20:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:54:52 UTC to 2016-06-07 20:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:14:52 UTC to 2016-06-07 21:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:34:52 UTC to 2016-06-07 21:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:54:52 UTC to 2016-06-07 21:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:14:52 UTC to 2016-06-07 22:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:34:52 UTC to 2016-06-07 22:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:54:52 UTC to 2016-06-07 22:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:14:52 UTC to 2016-06-07 23:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:34:53 UTC to 2016-06-07 23:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:55:06 UTC to 2016-06-07 23:55:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:14:52 UTC to 2016-06-08 00:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:34:54 UTC to 2016-06-08 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:54:52 UTC to 2016-06-08 00:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:14:52 UTC to 2016-06-08 01:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:34:55 UTC to 2016-06-08 01:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:54:52 UTC to 2016-06-08 01:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:14:53 UTC to 2016-06-08 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:34:54 UTC to 2016-06-08 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:55:08 UTC to 2016-06-08 02:55:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:14:52 UTC to 2016-06-08 03:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:34:52 UTC to 2016-06-08 03:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:54:52 UTC to 2016-06-08 03:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:14:52 UTC to 2016-06-08 04:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:34:52 UTC to 2016-06-08 04:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:54:52 UTC to 2016-06-08 04:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:14:52 UTC to 2016-06-08 05:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:34:52 UTC to 2016-06-08 05:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:54:52 UTC to 2016-06-08 05:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:14:52 UTC to 2016-06-08 06:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:34:52 UTC to 2016-06-08 06:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:54:52 UTC to 2016-06-08 06:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:14:52 UTC to 2016-06-08 07:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:34:52 UTC to 2016-06-08 07:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:54:52 UTC to 2016-06-08 07:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:14:52 UTC to 2016-06-08 08:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:34:52 UTC to 2016-06-08 08:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:54:52 UTC to 2016-06-08 08:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:14:51 UTC to 2016-06-08 09:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:34:52 UTC to 2016-06-08 09:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:54:51 UTC to 2016-06-08 09:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:14:51 UTC to 2016-06-08 10:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:34:51 UTC to 2016-06-08 10:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:54:51 UTC to 2016-06-08 10:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:14:51 UTC to 2016-06-08 11:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:34:51 UTC to 2016-06-08 11:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:54:51 UTC to 2016-06-08 11:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:14:51 UTC to 2016-06-08 12:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:34:51 UTC to 2016-06-08 12:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:54:51 UTC to 2016-06-08 12:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:14:51 UTC to 2016-06-08 13:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:34:51 UTC to 2016-06-08 13:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:54:51 UTC to 2016-06-08 13:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:14:51 UTC to 2016-06-08 14:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:34:51 UTC to 2016-06-08 14:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:54:51 UTC to 2016-06-08 14:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:14:51 UTC to 2016-06-08 15:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:34:51 UTC to 2016-06-08 15:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:54:51 UTC to 2016-06-08 15:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:14:51 UTC to 2016-06-08 16:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:34:51 UTC to 2016-06-08 16:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:54:51 UTC to 2016-06-08 16:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:14:51 UTC to 2016-06-08 17:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:34:51 UTC to 2016-06-08 17:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:54:51 UTC to 2016-06-08 17:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:14:51 UTC to 2016-06-08 18:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:34:51 UTC to 2016-06-08 18:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:54:51 UTC to 2016-06-08 18:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:14:51 UTC to 2016-06-08 19:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:34:51 UTC to 2016-06-08 19:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:54:51 UTC to 2016-06-08 19:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:14:51 UTC to 2016-06-08 20:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:34:52 UTC to 2016-06-08 20:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:54:51 UTC to 2016-06-08 20:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:14:51 UTC to 2016-06-08 21:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:34:51 UTC to 2016-06-08 21:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:54:51 UTC to 2016-06-08 21:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:14:51 UTC to 2016-06-08 22:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:34:51 UTC to 2016-06-08 22:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:54:51 UTC to 2016-06-08 22:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:14:51 UTC to 2016-06-08 23:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:34:51 UTC to 2016-06-08 23:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:54:51 UTC to 2016-06-08 23:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:14:51 UTC to 2016-06-09 00:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:34:51 UTC to 2016-06-09 00:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:54:51 UTC to 2016-06-09 00:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:14:51 UTC to 2016-06-09 01:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:34:51 UTC to 2016-06-09 01:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:54:51 UTC to 2016-06-09 01:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:14:51 UTC to 2016-06-09 02:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:34:51 UTC to 2016-06-09 02:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:54:51 UTC to 2016-06-09 02:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:14:51 UTC to 2016-06-09 03:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:34:51 UTC to 2016-06-09 03:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:54:51 UTC to 2016-06-09 03:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:14:51 UTC to 2016-06-09 04:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:34:51 UTC to 2016-06-09 04:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:54:51 UTC to 2016-06-09 04:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:14:51 UTC to 2016-06-09 05:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:34:51 UTC to 2016-06-09 05:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:54:51 UTC to 2016-06-09 05:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:14:51 UTC to 2016-06-09 06:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:34:51 UTC to 2016-06-09 06:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:54:51 UTC to 2016-06-09 06:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:14:51 UTC to 2016-06-09 07:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:34:51 UTC to 2016-06-09 07:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:54:51 UTC to 2016-06-09 07:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:14:51 UTC to 2016-06-09 08:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:34:51 UTC to 2016-06-09 08:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:54:51 UTC to 2016-06-09 08:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:14:51 UTC to 2016-06-09 09:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:34:51 UTC to 2016-06-09 09:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:54:51 UTC to 2016-06-09 09:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:14:50 UTC to 2016-06-09 10:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:34:51 UTC to 2016-06-09 10:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:54:51 UTC to 2016-06-09 10:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:14:51 UTC to 2016-06-09 11:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:34:51 UTC to 2016-06-09 11:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:54:51 UTC to 2016-06-09 11:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:14:50 UTC to 2016-06-09 12:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:34:50 UTC to 2016-06-09 12:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:54:50 UTC to 2016-06-09 12:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:14:50 UTC to 2016-06-09 13:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:34:50 UTC to 2016-06-09 13:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:54:50 UTC to 2016-06-09 13:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:14:50 UTC to 2016-06-09 14:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:34:50 UTC to 2016-06-09 14:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:54:51 UTC to 2016-06-09 14:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:14:51 UTC to 2016-06-09 15:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:34:51 UTC to 2016-06-09 15:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:54:50 UTC to 2016-06-09 15:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:14:50 UTC to 2016-06-09 16:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:34:50 UTC to 2016-06-09 16:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:54:50 UTC to 2016-06-09 16:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:14:50 UTC to 2016-06-09 17:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:34:50 UTC to 2016-06-09 17:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:54:50 UTC to 2016-06-09 17:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:14:50 UTC to 2016-06-09 18:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:34:50 UTC to 2016-06-09 18:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:54:50 UTC to 2016-06-09 18:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:14:51 UTC to 2016-06-09 19:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:34:50 UTC to 2016-06-09 19:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:54:50 UTC to 2016-06-09 19:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:14:50 UTC to 2016-06-09 20:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:34:50 UTC to 2016-06-09 20:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:54:50 UTC to 2016-06-09 20:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:14:50 UTC to 2016-06-09 21:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:34:50 UTC to 2016-06-09 21:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:54:50 UTC to 2016-06-09 21:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:14:50 UTC to 2016-06-09 22:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:34:50 UTC to 2016-06-09 22:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:54:50 UTC to 2016-06-09 22:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:14:50 UTC to 2016-06-09 23:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:34:50 UTC to 2016-06-09 23:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:54:50 UTC to 2016-06-09 23:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:14:50 UTC to 2016-06-10 00:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:34:50 UTC to 2016-06-10 00:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:54:50 UTC to 2016-06-10 00:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:14:50 UTC to 2016-06-10 01:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:34:50 UTC to 2016-06-10 01:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:54:50 UTC to 2016-06-10 01:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:14:50 UTC to 2016-06-10 02:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:34:50 UTC to 2016-06-10 02:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:54:50 UTC to 2016-06-10 02:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:14:50 UTC to 2016-06-10 03:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:34:50 UTC to 2016-06-10 03:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:54:50 UTC to 2016-06-10 03:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:14:50 UTC to 2016-06-10 04:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:34:50 UTC to 2016-06-10 04:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:54:50 UTC to 2016-06-10 04:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:14:50 UTC to 2016-06-10 05:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:34:50 UTC to 2016-06-10 05:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:54:50 UTC to 2016-06-10 05:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:14:50 UTC to 2016-06-10 06:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:34:50 UTC to 2016-06-10 06:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:54:50 UTC to 2016-06-10 06:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:14:50 UTC to 2016-06-10 07:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:34:50 UTC to 2016-06-10 07:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:54:50 UTC to 2016-06-10 07:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:14:50 UTC to 2016-06-10 08:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:34:50 UTC to 2016-06-10 08:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:54:50 UTC to 2016-06-10 08:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:14:50 UTC to 2016-06-10 09:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:34:50 UTC to 2016-06-10 09:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:54:50 UTC to 2016-06-10 09:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:14:50 UTC to 2016-06-10 10:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:34:50 UTC to 2016-06-10 10:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:54:50 UTC to 2016-06-10 10:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:14:50 UTC to 2016-06-10 11:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:34:50 UTC to 2016-06-10 11:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:54:50 UTC to 2016-06-10 11:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:14:50 UTC to 2016-06-10 12:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:34:50 UTC to 2016-06-10 12:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:54:50 UTC to 2016-06-10 12:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:14:50 UTC to 2016-06-10 13:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:34:50 UTC to 2016-06-10 13:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:54:50 UTC to 2016-06-10 13:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:14:49 UTC to 2016-06-10 14:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:34:49 UTC to 2016-06-10 14:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:54:50 UTC to 2016-06-10 14:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:14:50 UTC to 2016-06-10 15:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:34:49 UTC to 2016-06-10 15:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:54:49 UTC to 2016-06-10 15:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:14:49 UTC to 2016-06-10 16:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:34:50 UTC to 2016-06-10 16:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:54:49 UTC to 2016-06-10 16:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:14:49 UTC to 2016-06-10 17:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:34:49 UTC to 2016-06-10 17:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:54:49 UTC to 2016-06-10 17:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:14:49 UTC to 2016-06-10 18:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:34:50 UTC to 2016-06-10 18:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:54:50 UTC to 2016-06-10 18:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:14:49 UTC to 2016-06-10 19:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:34:52 UTC to 2016-06-10 19:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:54:49 UTC to 2016-06-10 19:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:14:49 UTC to 2016-06-10 20:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:34:49 UTC to 2016-06-10 20:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:54:49 UTC to 2016-06-10 20:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:14:49 UTC to 2016-06-10 21:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:34:49 UTC to 2016-06-10 21:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:54:49 UTC to 2016-06-10 21:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:14:49 UTC to 2016-06-10 22:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:34:49 UTC to 2016-06-10 22:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:54:49 UTC to 2016-06-10 22:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:14:49 UTC to 2016-06-10 23:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:34:49 UTC to 2016-06-10 23:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:54:49 UTC to 2016-06-10 23:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:14:49 UTC to 2016-06-11 00:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:34:49 UTC to 2016-06-11 00:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:54:49 UTC to 2016-06-11 00:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:14:49 UTC to 2016-06-11 01:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:34:49 UTC to 2016-06-11 01:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:54:49 UTC to 2016-06-11 01:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:14:49 UTC to 2016-06-11 02:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:34:49 UTC to 2016-06-11 02:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:54:49 UTC to 2016-06-11 02:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:14:49 UTC to 2016-06-11 03:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:34:49 UTC to 2016-06-11 03:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:54:49 UTC to 2016-06-11 03:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:14:49 UTC to 2016-06-11 04:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:34:49 UTC to 2016-06-11 04:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:54:49 UTC to 2016-06-11 04:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:14:49 UTC to 2016-06-11 05:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:34:49 UTC to 2016-06-11 05:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:54:49 UTC to 2016-06-11 05:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:14:49 UTC to 2016-06-11 06:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:34:49 UTC to 2016-06-11 06:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:54:49 UTC to 2016-06-11 06:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:14:49 UTC to 2016-06-11 07:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:34:49 UTC to 2016-06-11 07:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:54:49 UTC to 2016-06-11 07:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:14:49 UTC to 2016-06-11 08:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:34:54 UTC to 2016-06-11 08:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:54:49 UTC to 2016-06-11 08:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:14:49 UTC to 2016-06-11 09:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:34:49 UTC to 2016-06-11 09:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:54:49 UTC to 2016-06-11 09:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:14:49 UTC to 2016-06-11 10:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:34:49 UTC to 2016-06-11 10:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:54:49 UTC to 2016-06-11 10:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:14:49 UTC to 2016-06-11 11:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:34:49 UTC to 2016-06-11 11:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:54:49 UTC to 2016-06-11 11:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:14:49 UTC to 2016-06-11 12:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:34:49 UTC to 2016-06-11 12:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:54:49 UTC to 2016-06-11 12:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:14:49 UTC to 2016-06-11 13:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:34:49 UTC to 2016-06-11 13:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:54:49 UTC to 2016-06-11 13:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:14:49 UTC to 2016-06-11 14:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:34:49 UTC to 2016-06-11 14:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:54:49 UTC to 2016-06-11 14:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:14:49 UTC to 2016-06-11 15:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:34:49 UTC to 2016-06-11 15:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:54:49 UTC to 2016-06-11 15:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:14:49 UTC to 2016-06-11 16:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:34:49 UTC to 2016-06-11 16:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:54:49 UTC to 2016-06-11 16:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:14:49 UTC to 2016-06-11 17:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:34:49 UTC to 2016-06-11 17:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:54:48 UTC to 2016-06-11 17:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:14:48 UTC to 2016-06-11 18:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:34:49 UTC to 2016-06-11 18:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:54:49 UTC to 2016-06-11 18:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:14:49 UTC to 2016-06-11 19:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:34:49 UTC to 2016-06-11 19:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:54:48 UTC to 2016-06-11 19:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:14:48 UTC to 2016-06-11 20:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:34:48 UTC to 2016-06-11 20:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:54:48 UTC to 2016-06-11 20:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:14:48 UTC to 2016-06-11 21:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:34:48 UTC to 2016-06-11 21:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:54:48 UTC to 2016-06-11 21:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:14:48 UTC to 2016-06-11 22:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:34:48 UTC to 2016-06-11 22:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:54:48 UTC to 2016-06-11 22:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:14:48 UTC to 2016-06-11 23:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:34:49 UTC to 2016-06-11 23:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:54:48 UTC to 2016-06-11 23:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:14:49 UTC to 2016-06-12 00:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:34:48 UTC to 2016-06-12 00:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:54:48 UTC to 2016-06-12 00:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:14:48 UTC to 2016-06-12 01:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:34:48 UTC to 2016-06-12 01:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:54:48 UTC to 2016-06-12 01:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:14:48 UTC to 2016-06-12 02:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:34:48 UTC to 2016-06-12 02:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:54:48 UTC to 2016-06-12 02:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:14:48 UTC to 2016-06-12 03:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:34:48 UTC to 2016-06-12 03:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:54:48 UTC to 2016-06-12 03:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 04:14:48 UTC to 2016-06-12 04:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 04:54:48 UTC to 2016-06-12 04:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 05:14:48 UTC to 2016-06-12 05:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 05:54:48 UTC to 2016-06-12 05:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:14:48 UTC to 2016-06-12 06:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:34:48 UTC to 2016-06-12 06:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:54:48 UTC to 2016-06-12 06:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:14:48 UTC to 2016-06-12 07:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:34:48 UTC to 2016-06-12 07:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:54:48 UTC to 2016-06-12 07:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 08:34:48 UTC to 2016-06-12 08:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 08:54:48 UTC to 2016-06-12 08:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:14:48 UTC to 2016-06-12 09:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:34:48 UTC to 2016-06-12 09:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:54:48 UTC to 2016-06-12 09:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 10:14:48 UTC to 2016-06-12 10:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 10:34:48 UTC to 2016-06-12 10:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:14:48 UTC to 2016-06-12 11:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:34:48 UTC to 2016-06-12 11:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:54:48 UTC to 2016-06-12 11:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:14:48 UTC to 2016-06-12 12:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:34:48 UTC to 2016-06-12 12:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:54:48 UTC to 2016-06-12 12:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:14:48 UTC to 2016-06-12 13:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:34:48 UTC to 2016-06-12 13:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:54:48 UTC to 2016-06-12 13:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:14:48 UTC to 2016-06-12 14:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:34:48 UTC to 2016-06-12 14:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:54:50 UTC to 2016-06-12 14:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:14:48 UTC to 2016-06-12 15:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:34:48 UTC to 2016-06-12 15:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:54:48 UTC to 2016-06-12 15:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 16:34:48 UTC to 2016-06-12 16:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 16:54:48 UTC to 2016-06-12 16:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:14:48 UTC to 2016-06-12 17:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:34:48 UTC to 2016-06-12 17:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:54:48 UTC to 2016-06-12 17:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:14:48 UTC to 2016-06-12 18:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:34:48 UTC to 2016-06-12 18:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:54:48 UTC to 2016-06-12 18:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:14:48 UTC to 2016-06-12 19:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:34:48 UTC to 2016-06-12 19:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:54:48 UTC to 2016-06-12 19:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 20:14:48 UTC to 2016-06-12 20:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 20:34:48 UTC to 2016-06-12 20:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:14:47 UTC to 2016-06-12 21:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:34:48 UTC to 2016-06-12 21:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:54:47 UTC to 2016-06-12 21:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:14:48 UTC to 2016-06-12 22:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:34:47 UTC to 2016-06-12 22:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:54:47 UTC to 2016-06-12 22:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:14:48 UTC to 2016-06-12 23:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:34:47 UTC to 2016-06-12 23:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:54:47 UTC to 2016-06-12 23:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:14:47 UTC to 2016-06-13 00:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:34:47 UTC to 2016-06-13 00:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:54:47 UTC to 2016-06-13 00:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 01:14:47 UTC to 2016-06-13 01:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 01:54:47 UTC to 2016-06-13 01:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:14:47 UTC to 2016-06-13 02:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:34:47 UTC to 2016-06-13 02:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:54:47 UTC to 2016-06-13 02:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 03:34:47 UTC to 2016-06-13 03:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 03:54:47 UTC to 2016-06-13 03:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:14:47 UTC to 2016-06-13 04:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:34:47 UTC to 2016-06-13 04:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:54:47 UTC to 2016-06-13 04:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:14:48 UTC to 2016-06-13 05:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:34:47 UTC to 2016-06-13 05:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:54:47 UTC to 2016-06-13 05:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:14:47 UTC to 2016-06-13 06:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:34:47 UTC to 2016-06-13 06:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:54:47 UTC to 2016-06-13 06:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:14:47 UTC to 2016-06-13 07:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:34:47 UTC to 2016-06-13 07:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:54:47 UTC to 2016-06-13 07:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:14:47 UTC to 2016-06-13 08:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:34:47 UTC to 2016-06-13 08:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:54:47 UTC to 2016-06-13 08:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:14:47 UTC to 2016-06-13 09:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:34:47 UTC to 2016-06-13 09:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:54:47 UTC to 2016-06-13 09:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:14:47 UTC to 2016-06-13 10:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:34:47 UTC to 2016-06-13 10:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:54:47 UTC to 2016-06-13 10:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:14:47 UTC to 2016-06-13 11:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:34:47 UTC to 2016-06-13 11:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:54:47 UTC to 2016-06-13 11:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:14:47 UTC to 2016-06-13 12:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:34:47 UTC to 2016-06-13 12:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:54:47 UTC to 2016-06-13 12:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:14:47 UTC to 2016-06-13 13:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:34:47 UTC to 2016-06-13 13:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:54:47 UTC to 2016-06-13 13:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 14:14:47 UTC to 2016-06-13 14:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 14:34:50 UTC to 2016-06-13 14:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:14:47 UTC to 2016-06-13 15:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:34:47 UTC to 2016-06-13 15:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:54:47 UTC to 2016-06-13 15:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:14:47 UTC to 2016-06-13 16:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:34:47 UTC to 2016-06-13 16:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:54:47 UTC to 2016-06-13 16:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:14:47 UTC to 2016-06-13 17:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:34:47 UTC to 2016-06-13 17:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:54:47 UTC to 2016-06-13 17:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:14:47 UTC to 2016-06-13 18:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:34:47 UTC to 2016-06-13 18:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:54:47 UTC to 2016-06-13 18:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:14:47 UTC to 2016-06-13 19:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:34:47 UTC to 2016-06-13 19:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:54:47 UTC to 2016-06-13 19:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:14:47 UTC to 2016-06-13 20:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:34:47 UTC to 2016-06-13 20:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:54:47 UTC to 2016-06-13 20:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:14:47 UTC to 2016-06-13 21:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:34:47 UTC to 2016-06-13 21:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:54:47 UTC to 2016-06-13 21:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:14:47 UTC to 2016-06-13 22:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:34:47 UTC to 2016-06-13 22:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:54:47 UTC to 2016-06-13 22:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:14:47 UTC to 2016-06-13 23:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:34:47 UTC to 2016-06-13 23:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:54:47 UTC to 2016-06-13 23:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:14:46 UTC to 2016-06-14 00:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:34:46 UTC to 2016-06-14 00:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:54:46 UTC to 2016-06-14 00:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:14:46 UTC to 2016-06-14 01:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:34:46 UTC to 2016-06-14 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:54:46 UTC to 2016-06-14 01:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:14:46 UTC to 2016-06-14 02:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:34:46 UTC to 2016-06-14 02:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:54:46 UTC to 2016-06-14 02:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:14:46 UTC to 2016-06-14 03:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:34:46 UTC to 2016-06-14 03:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:54:46 UTC to 2016-06-14 03:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:14:46 UTC to 2016-06-14 04:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:34:46 UTC to 2016-06-14 04:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:54:46 UTC to 2016-06-14 04:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:14:46 UTC to 2016-06-14 05:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:34:46 UTC to 2016-06-14 05:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:54:46 UTC to 2016-06-14 05:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:14:46 UTC to 2016-06-14 06:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:34:46 UTC to 2016-06-14 06:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:54:46 UTC to 2016-06-14 06:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:14:46 UTC to 2016-06-14 07:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:34:46 UTC to 2016-06-14 07:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:54:46 UTC to 2016-06-14 07:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:14:46 UTC to 2016-06-14 08:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:34:46 UTC to 2016-06-14 08:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:54:46 UTC to 2016-06-14 08:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:14:46 UTC to 2016-06-14 09:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:34:46 UTC to 2016-06-14 09:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:54:46 UTC to 2016-06-14 09:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:14:46 UTC to 2016-06-14 10:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:34:46 UTC to 2016-06-14 10:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:54:46 UTC to 2016-06-14 10:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:14:46 UTC to 2016-06-14 11:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:34:46 UTC to 2016-06-14 11:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:54:46 UTC to 2016-06-14 11:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:14:46 UTC to 2016-06-14 12:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:34:46 UTC to 2016-06-14 12:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:54:46 UTC to 2016-06-14 12:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:14:46 UTC to 2016-06-14 13:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:34:46 UTC to 2016-06-14 13:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:54:46 UTC to 2016-06-14 13:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:14:46 UTC to 2016-06-14 14:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:34:46 UTC to 2016-06-14 14:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:54:46 UTC to 2016-06-14 14:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:14:46 UTC to 2016-06-14 15:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:34:46 UTC to 2016-06-14 15:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:54:46 UTC to 2016-06-14 15:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:14:46 UTC to 2016-06-14 16:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:34:46 UTC to 2016-06-14 16:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:54:46 UTC to 2016-06-14 16:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:14:46 UTC to 2016-06-14 17:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:34:46 UTC to 2016-06-14 17:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:54:46 UTC to 2016-06-14 17:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:14:46 UTC to 2016-06-14 18:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:34:46 UTC to 2016-06-14 18:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:54:46 UTC to 2016-06-14 18:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:14:46 UTC to 2016-06-14 19:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:34:46 UTC to 2016-06-14 19:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:54:46 UTC to 2016-06-14 19:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:14:46 UTC to 2016-06-14 20:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:34:46 UTC to 2016-06-14 20:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:54:46 UTC to 2016-06-14 20:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:14:46 UTC to 2016-06-14 21:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:34:46 UTC to 2016-06-14 21:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:54:46 UTC to 2016-06-14 21:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:14:46 UTC to 2016-06-14 22:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:34:46 UTC to 2016-06-14 22:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:54:46 UTC to 2016-06-14 22:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:14:46 UTC to 2016-06-14 23:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:34:46 UTC to 2016-06-14 23:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:54:46 UTC to 2016-06-14 23:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:14:46 UTC to 2016-06-15 00:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:34:46 UTC to 2016-06-15 00:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:54:46 UTC to 2016-06-15 00:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:14:46 UTC to 2016-06-15 01:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:34:46 UTC to 2016-06-15 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:54:46 UTC to 2016-06-15 01:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:14:46 UTC to 2016-06-15 02:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:34:46 UTC to 2016-06-15 02:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:54:46 UTC to 2016-06-15 02:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:14:46 UTC to 2016-06-15 03:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:34:45 UTC to 2016-06-15 03:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:54:46 UTC to 2016-06-15 03:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:14:46 UTC to 2016-06-15 04:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:34:46 UTC to 2016-06-15 04:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:54:46 UTC to 2016-06-15 04:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:14:45 UTC to 2016-06-15 05:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:34:46 UTC to 2016-06-15 05:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:54:45 UTC to 2016-06-15 05:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:14:45 UTC to 2016-06-15 06:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:34:45 UTC to 2016-06-15 06:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:54:45 UTC to 2016-06-15 06:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:14:45 UTC to 2016-06-15 07:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:34:45 UTC to 2016-06-15 07:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:54:45 UTC to 2016-06-15 07:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:14:45 UTC to 2016-06-15 08:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:34:45 UTC to 2016-06-15 08:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:54:45 UTC to 2016-06-15 08:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:14:45 UTC to 2016-06-15 09:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:34:45 UTC to 2016-06-15 09:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:54:45 UTC to 2016-06-15 09:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:14:45 UTC to 2016-06-15 10:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:34:45 UTC to 2016-06-15 10:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:54:45 UTC to 2016-06-15 10:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:14:45 UTC to 2016-06-15 11:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:34:45 UTC to 2016-06-15 11:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:54:45 UTC to 2016-06-15 11:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:14:45 UTC to 2016-06-15 12:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:34:45 UTC to 2016-06-15 12:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:54:45 UTC to 2016-06-15 12:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:14:45 UTC to 2016-06-15 13:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:34:45 UTC to 2016-06-15 13:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:54:45 UTC to 2016-06-15 13:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:14:45 UTC to 2016-06-15 14:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:34:46 UTC to 2016-06-15 14:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:54:45 UTC to 2016-06-15 14:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:14:46 UTC to 2016-06-15 15:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:34:46 UTC to 2016-06-15 15:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:54:45 UTC to 2016-06-15 15:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:14:45 UTC to 2016-06-15 16:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:34:45 UTC to 2016-06-15 16:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:54:45 UTC to 2016-06-15 16:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:14:45 UTC to 2016-06-15 17:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:34:45 UTC to 2016-06-15 17:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:54:45 UTC to 2016-06-15 17:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:14:45 UTC to 2016-06-15 18:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:34:45 UTC to 2016-06-15 18:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:54:45 UTC to 2016-06-15 18:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:14:45 UTC to 2016-06-15 19:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:34:45 UTC to 2016-06-15 19:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:54:45 UTC to 2016-06-15 19:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:14:45 UTC to 2016-06-15 20:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:34:45 UTC to 2016-06-15 20:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:54:45 UTC to 2016-06-15 20:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:14:48 UTC to 2016-06-15 21:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:34:45 UTC to 2016-06-15 21:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:54:45 UTC to 2016-06-15 21:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:14:45 UTC to 2016-06-15 22:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:34:45 UTC to 2016-06-15 22:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:54:45 UTC to 2016-06-15 22:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:14:45 UTC to 2016-06-15 23:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:34:45 UTC to 2016-06-15 23:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:55:03 UTC to 2016-06-15 23:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:14:45 UTC to 2016-06-16 00:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:34:45 UTC to 2016-06-16 00:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:54:45 UTC to 2016-06-16 00:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:14:45 UTC to 2016-06-16 01:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:34:46 UTC to 2016-06-16 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:54:45 UTC to 2016-06-16 01:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:14:45 UTC to 2016-06-16 02:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:34:45 UTC to 2016-06-16 02:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:54:45 UTC to 2016-06-16 02:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:14:45 UTC to 2016-06-16 03:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:34:45 UTC to 2016-06-16 03:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:54:45 UTC to 2016-06-16 03:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:14:45 UTC to 2016-06-16 04:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:34:45 UTC to 2016-06-16 04:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:54:45 UTC to 2016-06-16 04:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:14:45 UTC to 2016-06-16 05:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:34:45 UTC to 2016-06-16 05:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:54:45 UTC to 2016-06-16 05:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:14:45 UTC to 2016-06-16 06:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:34:45 UTC to 2016-06-16 06:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:54:45 UTC to 2016-06-16 06:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:14:45 UTC to 2016-06-16 07:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:34:45 UTC to 2016-06-16 07:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:54:45 UTC to 2016-06-16 07:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:14:44 UTC to 2016-06-16 08:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:34:45 UTC to 2016-06-16 08:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:54:45 UTC to 2016-06-16 08:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:14:45 UTC to 2016-06-16 09:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:34:45 UTC to 2016-06-16 09:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:54:45 UTC to 2016-06-16 09:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:14:44 UTC to 2016-06-16 10:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:34:44 UTC to 2016-06-16 10:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:54:44 UTC to 2016-06-16 10:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:14:45 UTC to 2016-06-16 11:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:34:44 UTC to 2016-06-16 11:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:54:44 UTC to 2016-06-16 11:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:14:44 UTC to 2016-06-16 12:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:34:45 UTC to 2016-06-16 12:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:54:44 UTC to 2016-06-16 12:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:14:47 UTC to 2016-06-16 13:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:34:45 UTC to 2016-06-16 13:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:54:44 UTC to 2016-06-16 13:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:14:44 UTC to 2016-06-16 14:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:34:44 UTC to 2016-06-16 14:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:54:44 UTC to 2016-06-16 14:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:14:44 UTC to 2016-06-16 15:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:34:45 UTC to 2016-06-16 15:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:54:45 UTC to 2016-06-16 15:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:14:44 UTC to 2016-06-16 16:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:34:44 UTC to 2016-06-16 16:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:54:44 UTC to 2016-06-16 16:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:14:44 UTC to 2016-06-16 17:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:34:44 UTC to 2016-06-16 17:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:54:44 UTC to 2016-06-16 17:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:14:44 UTC to 2016-06-16 18:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:34:44 UTC to 2016-06-16 18:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:54:44 UTC to 2016-06-16 18:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:14:44 UTC to 2016-06-16 19:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:34:44 UTC to 2016-06-16 19:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:54:44 UTC to 2016-06-16 19:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:14:44 UTC to 2016-06-16 20:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:34:44 UTC to 2016-06-16 20:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:54:44 UTC to 2016-06-16 20:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:14:44 UTC to 2016-06-16 21:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:34:44 UTC to 2016-06-16 21:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:54:44 UTC to 2016-06-16 21:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:14:44 UTC to 2016-06-16 22:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:34:44 UTC to 2016-06-16 22:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:54:44 UTC to 2016-06-16 22:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:14:44 UTC to 2016-06-16 23:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:34:44 UTC to 2016-06-16 23:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:54:44 UTC to 2016-06-16 23:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:14:45 UTC to 2016-06-17 00:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:34:44 UTC to 2016-06-17 00:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:54:44 UTC to 2016-06-17 00:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:14:44 UTC to 2016-06-17 01:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:34:44 UTC to 2016-06-17 01:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:54:44 UTC to 2016-06-17 01:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:14:44 UTC to 2016-06-17 02:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:34:44 UTC to 2016-06-17 02:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:54:44 UTC to 2016-06-17 02:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:14:44 UTC to 2016-06-17 03:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:34:44 UTC to 2016-06-17 03:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:54:44 UTC to 2016-06-17 03:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:14:44 UTC to 2016-06-17 04:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:34:44 UTC to 2016-06-17 04:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:54:44 UTC to 2016-06-17 04:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:14:44 UTC to 2016-06-17 05:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:34:44 UTC to 2016-06-17 05:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:54:44 UTC to 2016-06-17 05:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:14:44 UTC to 2016-06-17 06:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:34:44 UTC to 2016-06-17 06:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:54:44 UTC to 2016-06-17 06:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:14:44 UTC to 2016-06-17 07:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:34:44 UTC to 2016-06-17 07:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:54:44 UTC to 2016-06-17 07:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:14:44 UTC to 2016-06-17 08:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:34:44 UTC to 2016-06-17 08:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:54:44 UTC to 2016-06-17 08:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:14:44 UTC to 2016-06-17 09:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:34:44 UTC to 2016-06-17 09:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:54:44 UTC to 2016-06-17 09:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:14:44 UTC to 2016-06-17 10:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:34:44 UTC to 2016-06-17 10:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:54:44 UTC to 2016-06-17 10:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:14:44 UTC to 2016-06-17 11:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:34:44 UTC to 2016-06-17 11:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:54:44 UTC to 2016-06-17 11:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:14:43 UTC to 2016-06-17 12:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:34:44 UTC to 2016-06-17 12:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:54:44 UTC to 2016-06-17 12:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:14:44 UTC to 2016-06-17 13:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:34:43 UTC to 2016-06-17 13:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:54:43 UTC to 2016-06-17 13:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:14:43 UTC to 2016-06-17 14:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:34:43 UTC to 2016-06-17 14:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:54:43 UTC to 2016-06-17 14:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:14:43 UTC to 2016-06-17 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:34:44 UTC to 2016-06-17 15:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:54:43 UTC to 2016-06-17 15:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:14:43 UTC to 2016-06-17 16:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:34:43 UTC to 2016-06-17 16:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:54:43 UTC to 2016-06-17 16:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:14:43 UTC to 2016-06-17 17:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:34:43 UTC to 2016-06-17 17:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:54:43 UTC to 2016-06-17 17:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:14:43 UTC to 2016-06-17 18:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:34:43 UTC to 2016-06-17 18:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:54:43 UTC to 2016-06-17 18:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:14:43 UTC to 2016-06-17 19:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:34:43 UTC to 2016-06-17 19:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:54:43 UTC to 2016-06-17 19:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:14:43 UTC to 2016-06-17 20:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:34:43 UTC to 2016-06-17 20:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:54:43 UTC to 2016-06-17 20:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:14:43 UTC to 2016-06-17 21:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:34:43 UTC to 2016-06-17 21:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:54:43 UTC to 2016-06-17 21:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:14:43 UTC to 2016-06-17 22:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:34:43 UTC to 2016-06-17 22:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:54:43 UTC to 2016-06-17 22:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:14:43 UTC to 2016-06-17 23:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:34:43 UTC to 2016-06-17 23:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:54:43 UTC to 2016-06-17 23:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:14:43 UTC to 2016-06-18 00:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:34:43 UTC to 2016-06-18 00:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:54:43 UTC to 2016-06-18 00:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:14:43 UTC to 2016-06-18 01:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:34:43 UTC to 2016-06-18 01:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:54:43 UTC to 2016-06-18 01:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:14:43 UTC to 2016-06-18 02:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:34:43 UTC to 2016-06-18 02:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:54:43 UTC to 2016-06-18 02:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:14:43 UTC to 2016-06-18 03:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:34:43 UTC to 2016-06-18 03:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:54:43 UTC to 2016-06-18 03:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:14:43 UTC to 2016-06-18 04:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:34:43 UTC to 2016-06-18 04:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:54:43 UTC to 2016-06-18 04:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:14:43 UTC to 2016-06-18 05:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:34:43 UTC to 2016-06-18 05:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:54:43 UTC to 2016-06-18 05:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:14:43 UTC to 2016-06-18 06:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:34:43 UTC to 2016-06-18 06:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:54:43 UTC to 2016-06-18 06:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:14:43 UTC to 2016-06-18 07:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:34:43 UTC to 2016-06-18 07:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:54:43 UTC to 2016-06-18 07:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:14:43 UTC to 2016-06-18 08:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:34:43 UTC to 2016-06-18 08:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:54:43 UTC to 2016-06-18 08:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:14:43 UTC to 2016-06-18 09:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:34:43 UTC to 2016-06-18 09:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:54:43 UTC to 2016-06-18 09:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:14:43 UTC to 2016-06-18 10:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:34:43 UTC to 2016-06-18 10:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:54:43 UTC to 2016-06-18 10:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:14:43 UTC to 2016-06-18 11:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:34:43 UTC to 2016-06-18 11:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:54:43 UTC to 2016-06-18 11:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:14:43 UTC to 2016-06-18 12:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:34:43 UTC to 2016-06-18 12:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:54:43 UTC to 2016-06-18 12:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:14:43 UTC to 2016-06-18 13:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:34:43 UTC to 2016-06-18 13:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:54:43 UTC to 2016-06-18 13:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:14:43 UTC to 2016-06-18 14:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:34:43 UTC to 2016-06-18 14:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:54:43 UTC to 2016-06-18 14:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:14:43 UTC to 2016-06-18 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:34:43 UTC to 2016-06-18 15:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:54:43 UTC to 2016-06-18 15:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:14:44 UTC to 2016-06-18 16:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:34:42 UTC to 2016-06-18 16:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:54:42 UTC to 2016-06-18 16:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:14:42 UTC to 2016-06-18 17:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:34:42 UTC to 2016-06-18 17:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:54:42 UTC to 2016-06-18 17:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:14:42 UTC to 2016-06-18 18:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:34:42 UTC to 2016-06-18 18:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:54:42 UTC to 2016-06-18 18:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:14:42 UTC to 2016-06-18 19:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:34:42 UTC to 2016-06-18 19:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:54:42 UTC to 2016-06-18 19:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:14:42 UTC to 2016-06-18 20:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:34:42 UTC to 2016-06-18 20:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:54:42 UTC to 2016-06-18 20:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:14:42 UTC to 2016-06-18 21:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:34:42 UTC to 2016-06-18 21:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:54:42 UTC to 2016-06-18 21:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:14:42 UTC to 2016-06-18 22:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:34:42 UTC to 2016-06-18 22:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:54:42 UTC to 2016-06-18 22:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:14:42 UTC to 2016-06-18 23:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:34:42 UTC to 2016-06-18 23:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:54:42 UTC to 2016-06-18 23:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:14:42 UTC to 2016-06-19 00:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:34:42 UTC to 2016-06-19 00:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:54:42 UTC to 2016-06-19 00:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:14:42 UTC to 2016-06-19 01:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:34:42 UTC to 2016-06-19 01:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:54:42 UTC to 2016-06-19 01:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:14:42 UTC to 2016-06-19 02:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:34:42 UTC to 2016-06-19 02:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:54:42 UTC to 2016-06-19 02:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:14:42 UTC to 2016-06-19 03:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:34:42 UTC to 2016-06-19 03:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:54:42 UTC to 2016-06-19 03:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:14:42 UTC to 2016-06-19 04:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:34:42 UTC to 2016-06-19 04:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:54:42 UTC to 2016-06-19 04:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:14:42 UTC to 2016-06-19 05:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:34:42 UTC to 2016-06-19 05:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:54:42 UTC to 2016-06-19 05:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:14:42 UTC to 2016-06-19 06:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:34:42 UTC to 2016-06-19 06:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:54:42 UTC to 2016-06-19 06:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:14:42 UTC to 2016-06-19 07:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:34:42 UTC to 2016-06-19 07:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:54:42 UTC to 2016-06-19 07:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:14:42 UTC to 2016-06-19 08:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:34:42 UTC to 2016-06-19 08:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:54:42 UTC to 2016-06-19 08:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:14:42 UTC to 2016-06-19 09:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:34:42 UTC to 2016-06-19 09:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:54:42 UTC to 2016-06-19 09:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:14:42 UTC to 2016-06-19 10:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:34:42 UTC to 2016-06-19 10:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:54:42 UTC to 2016-06-19 10:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:14:42 UTC to 2016-06-19 11:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:34:42 UTC to 2016-06-19 11:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:54:42 UTC to 2016-06-19 11:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:14:42 UTC to 2016-06-19 12:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:34:42 UTC to 2016-06-19 12:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:54:42 UTC to 2016-06-19 12:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:14:42 UTC to 2016-06-19 13:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:34:42 UTC to 2016-06-19 13:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:54:42 UTC to 2016-06-19 13:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:14:42 UTC to 2016-06-19 14:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:34:42 UTC to 2016-06-19 14:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:54:42 UTC to 2016-06-19 14:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:14:43 UTC to 2016-06-19 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:34:42 UTC to 2016-06-19 15:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:54:42 UTC to 2016-06-19 15:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:14:42 UTC to 2016-06-19 16:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:34:42 UTC to 2016-06-19 16:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:54:42 UTC to 2016-06-19 16:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:14:42 UTC to 2016-06-19 17:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:34:42 UTC to 2016-06-19 17:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:54:42 UTC to 2016-06-19 17:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:14:42 UTC to 2016-06-19 18:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:34:42 UTC to 2016-06-19 18:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:54:42 UTC to 2016-06-19 18:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:14:42 UTC to 2016-06-19 19:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:34:41 UTC to 2016-06-19 19:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:54:41 UTC to 2016-06-19 19:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:14:41 UTC to 2016-06-19 20:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:34:41 UTC to 2016-06-19 20:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:54:41 UTC to 2016-06-19 20:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:14:41 UTC to 2016-06-19 21:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:34:41 UTC to 2016-06-19 21:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:54:41 UTC to 2016-06-19 21:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:14:41 UTC to 2016-06-19 22:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:34:41 UTC to 2016-06-19 22:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:54:41 UTC to 2016-06-19 22:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:14:41 UTC to 2016-06-19 23:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:34:41 UTC to 2016-06-19 23:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:54:41 UTC to 2016-06-19 23:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:14:41 UTC to 2016-06-20 00:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:34:41 UTC to 2016-06-20 00:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:54:41 UTC to 2016-06-20 00:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:14:41 UTC to 2016-06-20 01:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:34:41 UTC to 2016-06-20 01:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:54:41 UTC to 2016-06-20 01:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:14:41 UTC to 2016-06-20 02:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:34:41 UTC to 2016-06-20 02:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:54:41 UTC to 2016-06-20 02:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:14:41 UTC to 2016-06-20 03:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:34:41 UTC to 2016-06-20 03:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:54:41 UTC to 2016-06-20 03:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:14:41 UTC to 2016-06-20 04:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:34:41 UTC to 2016-06-20 04:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:54:41 UTC to 2016-06-20 04:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:14:41 UTC to 2016-06-20 05:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:34:41 UTC to 2016-06-20 05:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:54:41 UTC to 2016-06-20 05:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:14:41 UTC to 2016-06-20 06:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:34:41 UTC to 2016-06-20 06:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:54:41 UTC to 2016-06-20 06:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:14:41 UTC to 2016-06-20 07:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:34:41 UTC to 2016-06-20 07:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:54:41 UTC to 2016-06-20 07:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:14:41 UTC to 2016-06-20 08:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:34:41 UTC to 2016-06-20 08:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:54:41 UTC to 2016-06-20 08:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:14:41 UTC to 2016-06-20 09:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:34:41 UTC to 2016-06-20 09:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:54:41 UTC to 2016-06-20 09:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:14:41 UTC to 2016-06-20 10:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:34:41 UTC to 2016-06-20 10:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:54:41 UTC to 2016-06-20 10:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:14:41 UTC to 2016-06-20 11:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:34:41 UTC to 2016-06-20 11:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:54:41 UTC to 2016-06-20 11:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:14:41 UTC to 2016-06-20 12:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:34:41 UTC to 2016-06-20 12:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:54:41 UTC to 2016-06-20 12:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:14:41 UTC to 2016-06-20 13:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:34:41 UTC to 2016-06-20 13:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:54:41 UTC to 2016-06-20 13:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:14:41 UTC to 2016-06-20 14:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:34:41 UTC to 2016-06-20 14:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:54:41 UTC to 2016-06-20 14:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:14:41 UTC to 2016-06-20 15:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:34:41 UTC to 2016-06-20 15:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:54:41 UTC to 2016-06-20 15:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:14:41 UTC to 2016-06-20 16:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:34:41 UTC to 2016-06-20 16:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:54:41 UTC to 2016-06-20 16:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:14:41 UTC to 2016-06-20 17:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:34:41 UTC to 2016-06-20 17:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:54:41 UTC to 2016-06-20 17:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:14:41 UTC to 2016-06-20 18:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:34:41 UTC to 2016-06-20 18:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:54:41 UTC to 2016-06-20 18:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:14:41 UTC to 2016-06-20 19:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:34:41 UTC to 2016-06-20 19:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:54:41 UTC to 2016-06-20 19:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:14:41 UTC to 2016-06-20 20:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:34:41 UTC to 2016-06-20 20:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:54:41 UTC to 2016-06-20 20:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:14:41 UTC to 2016-06-20 21:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:34:41 UTC to 2016-06-20 21:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:54:41 UTC to 2016-06-20 21:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:14:40 UTC to 2016-06-20 22:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:34:40 UTC to 2016-06-20 22:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:54:41 UTC to 2016-06-20 22:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:14:41 UTC to 2016-06-20 23:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:34:41 UTC to 2016-06-20 23:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:54:41 UTC to 2016-06-20 23:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:14:41 UTC to 2016-06-21 00:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:34:40 UTC to 2016-06-21 00:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:54:40 UTC to 2016-06-21 00:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:14:40 UTC to 2016-06-21 01:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:34:40 UTC to 2016-06-21 01:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:54:40 UTC to 2016-06-21 01:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:14:40 UTC to 2016-06-21 02:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:34:40 UTC to 2016-06-21 02:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:54:40 UTC to 2016-06-21 02:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:14:40 UTC to 2016-06-21 03:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:34:40 UTC to 2016-06-21 03:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:54:40 UTC to 2016-06-21 03:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:14:40 UTC to 2016-06-21 04:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:34:40 UTC to 2016-06-21 04:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:54:40 UTC to 2016-06-21 04:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:14:40 UTC to 2016-06-21 05:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:34:40 UTC to 2016-06-21 05:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:54:40 UTC to 2016-06-21 05:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:14:40 UTC to 2016-06-21 06:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:34:40 UTC to 2016-06-21 06:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:54:40 UTC to 2016-06-21 06:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:14:40 UTC to 2016-06-21 07:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:34:40 UTC to 2016-06-21 07:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:54:40 UTC to 2016-06-21 07:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:14:40 UTC to 2016-06-21 08:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:34:40 UTC to 2016-06-21 08:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:54:40 UTC to 2016-06-21 08:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:14:40 UTC to 2016-06-21 09:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:34:40 UTC to 2016-06-21 09:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:54:40 UTC to 2016-06-21 09:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:14:40 UTC to 2016-06-21 10:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:34:40 UTC to 2016-06-21 10:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:54:40 UTC to 2016-06-21 10:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:14:40 UTC to 2016-06-21 11:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:34:40 UTC to 2016-06-21 11:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:54:40 UTC to 2016-06-21 11:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:14:40 UTC to 2016-06-21 12:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:34:40 UTC to 2016-06-21 12:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:54:40 UTC to 2016-06-21 12:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:14:40 UTC to 2016-06-21 13:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:34:40 UTC to 2016-06-21 13:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:54:40 UTC to 2016-06-21 13:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:14:40 UTC to 2016-06-21 14:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:34:40 UTC to 2016-06-21 14:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:54:40 UTC to 2016-06-21 14:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:14:40 UTC to 2016-06-21 15:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:34:40 UTC to 2016-06-21 15:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:54:40 UTC to 2016-06-21 15:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:14:40 UTC to 2016-06-21 16:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:34:40 UTC to 2016-06-21 16:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:54:40 UTC to 2016-06-21 16:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:14:40 UTC to 2016-06-21 17:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:34:40 UTC to 2016-06-21 17:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:54:40 UTC to 2016-06-21 17:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:14:40 UTC to 2016-06-21 18:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:34:40 UTC to 2016-06-21 18:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:54:40 UTC to 2016-06-21 18:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:14:40 UTC to 2016-06-21 19:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:34:40 UTC to 2016-06-21 19:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:54:40 UTC to 2016-06-21 19:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:14:40 UTC to 2016-06-21 20:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:34:40 UTC to 2016-06-21 20:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:54:40 UTC to 2016-06-21 20:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:14:40 UTC to 2016-06-21 21:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:34:40 UTC to 2016-06-21 21:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:54:40 UTC to 2016-06-21 21:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:14:40 UTC to 2016-06-21 22:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:34:40 UTC to 2016-06-21 22:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:54:40 UTC to 2016-06-21 22:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:14:40 UTC to 2016-06-21 23:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:34:40 UTC to 2016-06-21 23:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:54:40 UTC to 2016-06-21 23:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:14:40 UTC to 2016-06-22 00:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:34:40 UTC to 2016-06-22 00:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:54:40 UTC to 2016-06-22 00:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:14:39 UTC to 2016-06-22 01:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:34:39 UTC to 2016-06-22 01:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:54:39 UTC to 2016-06-22 01:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:14:39 UTC to 2016-06-22 02:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:34:40 UTC to 2016-06-22 02:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:54:40 UTC to 2016-06-22 02:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:14:39 UTC to 2016-06-22 03:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:34:40 UTC to 2016-06-22 03:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:54:40 UTC to 2016-06-22 03:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:14:39 UTC to 2016-06-22 04:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:34:40 UTC to 2016-06-22 04:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:54:40 UTC to 2016-06-22 04:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:14:39 UTC to 2016-06-22 05:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:34:39 UTC to 2016-06-22 05:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:54:39 UTC to 2016-06-22 05:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:14:39 UTC to 2016-06-22 06:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:34:39 UTC to 2016-06-22 06:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:54:39 UTC to 2016-06-22 06:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:14:39 UTC to 2016-06-22 07:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:34:39 UTC to 2016-06-22 07:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:54:39 UTC to 2016-06-22 07:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:14:39 UTC to 2016-06-22 08:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:34:39 UTC to 2016-06-22 08:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:54:39 UTC to 2016-06-22 08:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 09:14:39 UTC to 2016-06-22 09:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 09:34:39 UTC to 2016-06-22 09:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:20:03 UTC to 2016-06-23 20:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:30:03 UTC to 2016-06-23 20:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:50:03 UTC to 2016-06-23 20:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:10:03 UTC to 2016-06-23 21:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:30:03 UTC to 2016-06-23 21:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:50:03 UTC to 2016-06-23 21:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:10:03 UTC to 2016-06-23 22:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:30:03 UTC to 2016-06-23 22:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:50:03 UTC to 2016-06-23 22:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:10:03 UTC to 2016-06-23 23:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:30:03 UTC to 2016-06-23 23:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:50:03 UTC to 2016-06-23 23:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:10:03 UTC to 2016-06-24 00:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:30:03 UTC to 2016-06-24 00:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:50:03 UTC to 2016-06-24 00:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:10:03 UTC to 2016-06-24 01:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:30:03 UTC to 2016-06-24 01:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:50:03 UTC to 2016-06-24 01:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:10:03 UTC to 2016-06-24 02:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:30:03 UTC to 2016-06-24 02:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:50:03 UTC to 2016-06-24 02:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:10:03 UTC to 2016-06-24 03:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:30:03 UTC to 2016-06-24 03:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:50:03 UTC to 2016-06-24 03:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:10:03 UTC to 2016-06-24 04:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:30:03 UTC to 2016-06-24 04:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:50:03 UTC to 2016-06-24 04:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:10:03 UTC to 2016-06-24 05:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:30:03 UTC to 2016-06-24 05:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:50:03 UTC to 2016-06-24 05:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:10:03 UTC to 2016-06-24 06:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:30:03 UTC to 2016-06-24 06:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:50:03 UTC to 2016-06-24 06:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:10:03 UTC to 2016-06-24 07:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:30:03 UTC to 2016-06-24 07:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:50:03 UTC to 2016-06-24 07:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:10:03 UTC to 2016-06-24 08:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:30:03 UTC to 2016-06-24 08:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:50:03 UTC to 2016-06-24 08:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:10:03 UTC to 2016-06-24 09:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:30:03 UTC to 2016-06-24 09:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:50:03 UTC to 2016-06-24 09:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:10:03 UTC to 2016-06-24 10:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:30:03 UTC to 2016-06-24 10:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:50:02 UTC to 2016-06-24 10:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:10:03 UTC to 2016-06-24 11:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:30:03 UTC to 2016-06-24 11:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:50:02 UTC to 2016-06-24 11:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:10:02 UTC to 2016-06-24 12:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:30:02 UTC to 2016-06-24 12:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:50:02 UTC to 2016-06-24 12:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:10:02 UTC to 2016-06-24 13:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:30:02 UTC to 2016-06-24 13:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:50:02 UTC to 2016-06-24 13:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:10:02 UTC to 2016-06-24 14:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:30:02 UTC to 2016-06-24 14:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:50:02 UTC to 2016-06-24 14:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:10:02 UTC to 2016-06-24 15:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:30:02 UTC to 2016-06-24 15:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:50:02 UTC to 2016-06-24 15:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:10:02 UTC to 2016-06-24 16:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:30:02 UTC to 2016-06-24 16:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:50:02 UTC to 2016-06-24 16:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:10:02 UTC to 2016-06-24 17:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:30:02 UTC to 2016-06-24 17:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:50:02 UTC to 2016-06-24 17:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:10:02 UTC to 2016-06-24 18:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:30:02 UTC to 2016-06-24 18:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:50:02 UTC to 2016-06-24 18:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:10:02 UTC to 2016-06-24 19:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:30:02 UTC to 2016-06-24 19:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:50:02 UTC to 2016-06-24 19:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:10:02 UTC to 2016-06-24 20:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:30:02 UTC to 2016-06-24 20:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:50:02 UTC to 2016-06-24 20:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:10:02 UTC to 2016-06-24 21:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:30:02 UTC to 2016-06-24 21:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:50:02 UTC to 2016-06-24 21:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:10:02 UTC to 2016-06-24 22:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:30:02 UTC to 2016-06-24 22:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:50:02 UTC to 2016-06-24 22:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:10:02 UTC to 2016-06-24 23:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:30:02 UTC to 2016-06-24 23:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:50:02 UTC to 2016-06-24 23:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:10:02 UTC to 2016-06-25 00:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:30:02 UTC to 2016-06-25 00:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:50:02 UTC to 2016-06-25 00:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:10:02 UTC to 2016-06-25 01:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:30:02 UTC to 2016-06-25 01:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:50:02 UTC to 2016-06-25 01:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:10:02 UTC to 2016-06-25 02:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:30:02 UTC to 2016-06-25 02:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:50:02 UTC to 2016-06-25 02:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:10:02 UTC to 2016-06-25 03:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:30:02 UTC to 2016-06-25 03:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:50:02 UTC to 2016-06-25 03:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:10:02 UTC to 2016-06-25 04:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:30:02 UTC to 2016-06-25 04:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:50:02 UTC to 2016-06-25 04:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:10:02 UTC to 2016-06-25 05:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:30:02 UTC to 2016-06-25 05:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:50:02 UTC to 2016-06-25 05:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:10:02 UTC to 2016-06-25 06:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:30:02 UTC to 2016-06-25 06:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:50:02 UTC to 2016-06-25 06:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:10:02 UTC to 2016-06-25 07:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:30:02 UTC to 2016-06-25 07:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:50:02 UTC to 2016-06-25 07:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:10:02 UTC to 2016-06-25 08:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:30:02 UTC to 2016-06-25 08:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:50:02 UTC to 2016-06-25 08:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 09:10:02 UTC to 2016-06-25 09:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 09:30:02 UTC to 2016-06-25 09:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 14:24:30 UTC to 2016-06-26 14:24:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 15:04:30 UTC to 2016-06-26 15:04:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 15:44:30 UTC to 2016-06-26 15:44:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:04:29 UTC to 2016-06-26 16:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:24:30 UTC to 2016-06-26 16:24:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:44:29 UTC to 2016-06-26 16:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:04:29 UTC to 2016-06-26 17:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:24:29 UTC to 2016-06-26 17:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:44:29 UTC to 2016-06-26 17:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:04:29 UTC to 2016-06-26 18:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:24:29 UTC to 2016-06-26 18:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:44:29 UTC to 2016-06-26 18:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:04:29 UTC to 2016-06-26 19:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:24:29 UTC to 2016-06-26 19:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:44:29 UTC to 2016-06-26 19:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:04:29 UTC to 2016-06-26 20:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:24:29 UTC to 2016-06-26 20:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:44:29 UTC to 2016-06-26 20:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:04:29 UTC to 2016-06-26 21:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:24:29 UTC to 2016-06-26 21:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:44:29 UTC to 2016-06-26 21:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:04:29 UTC to 2016-06-26 22:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:24:29 UTC to 2016-06-26 22:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:44:29 UTC to 2016-06-26 22:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 23:04:29 UTC to 2016-06-26 23:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 23:24:29 UTC to 2016-06-26 23:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:04:29 UTC to 2016-06-27 00:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:24:29 UTC to 2016-06-27 00:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:44:29 UTC to 2016-06-27 00:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:04:29 UTC to 2016-06-27 01:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:24:29 UTC to 2016-06-27 01:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:44:29 UTC to 2016-06-27 01:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:04:29 UTC to 2016-06-27 02:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:24:29 UTC to 2016-06-27 02:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:44:29 UTC to 2016-06-27 02:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:04:29 UTC to 2016-06-27 03:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:24:29 UTC to 2016-06-27 03:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:44:29 UTC to 2016-06-27 03:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:04:29 UTC to 2016-06-27 04:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:24:29 UTC to 2016-06-27 04:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:44:29 UTC to 2016-06-27 04:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:04:29 UTC to 2016-06-27 05:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:24:29 UTC to 2016-06-27 05:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:44:29 UTC to 2016-06-27 05:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:04:29 UTC to 2016-06-27 06:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:24:29 UTC to 2016-06-27 06:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:44:29 UTC to 2016-06-27 06:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:04:29 UTC to 2016-06-27 07:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:24:29 UTC to 2016-06-27 07:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:44:29 UTC to 2016-06-27 07:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:04:29 UTC to 2016-06-27 08:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:24:29 UTC to 2016-06-27 08:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:44:29 UTC to 2016-06-27 08:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:04:29 UTC to 2016-06-27 09:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:24:29 UTC to 2016-06-27 09:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:44:29 UTC to 2016-06-27 09:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:04:29 UTC to 2016-06-27 10:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:24:29 UTC to 2016-06-27 10:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:44:29 UTC to 2016-06-27 10:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:04:29 UTC to 2016-06-27 11:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:24:29 UTC to 2016-06-27 11:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:44:29 UTC to 2016-06-27 11:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:04:29 UTC to 2016-06-27 12:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:24:29 UTC to 2016-06-27 12:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:44:29 UTC to 2016-06-27 12:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:04:29 UTC to 2016-06-27 13:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:24:29 UTC to 2016-06-27 13:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:44:29 UTC to 2016-06-27 13:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:04:29 UTC to 2016-06-27 14:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:24:29 UTC to 2016-06-27 14:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:44:29 UTC to 2016-06-27 14:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:04:29 UTC to 2016-06-27 15:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:24:29 UTC to 2016-06-27 15:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:44:29 UTC to 2016-06-27 15:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:04:29 UTC to 2016-06-27 16:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:24:29 UTC to 2016-06-27 16:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:44:29 UTC to 2016-06-27 16:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:04:29 UTC to 2016-06-27 17:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:24:29 UTC to 2016-06-27 17:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:44:29 UTC to 2016-06-27 17:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:04:29 UTC to 2016-06-27 18:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:24:29 UTC to 2016-06-27 18:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:44:29 UTC to 2016-06-27 18:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:04:29 UTC to 2016-06-27 19:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:24:29 UTC to 2016-06-27 19:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:44:29 UTC to 2016-06-27 19:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:04:28 UTC to 2016-06-27 20:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:24:29 UTC to 2016-06-27 20:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:44:28 UTC to 2016-06-27 20:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:04:29 UTC to 2016-06-27 21:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:24:29 UTC to 2016-06-27 21:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:44:29 UTC to 2016-06-27 21:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:04:29 UTC to 2016-06-27 22:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:24:28 UTC to 2016-06-27 22:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:44:28 UTC to 2016-06-27 22:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:04:28 UTC to 2016-06-27 23:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:24:28 UTC to 2016-06-27 23:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:44:28 UTC to 2016-06-27 23:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:04:28 UTC to 2016-06-28 00:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:24:28 UTC to 2016-06-28 00:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:44:28 UTC to 2016-06-28 00:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:04:28 UTC to 2016-06-28 01:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:24:28 UTC to 2016-06-28 01:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:44:28 UTC to 2016-06-28 01:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:04:28 UTC to 2016-06-28 02:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:24:28 UTC to 2016-06-28 02:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:44:28 UTC to 2016-06-28 02:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:04:28 UTC to 2016-06-28 03:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:24:28 UTC to 2016-06-28 03:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:44:28 UTC to 2016-06-28 03:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:04:28 UTC to 2016-06-28 04:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:24:28 UTC to 2016-06-28 04:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:44:28 UTC to 2016-06-28 04:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:04:28 UTC to 2016-06-28 05:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:24:28 UTC to 2016-06-28 05:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:44:28 UTC to 2016-06-28 05:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:04:28 UTC to 2016-06-28 06:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:24:28 UTC to 2016-06-28 06:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:44:28 UTC to 2016-06-28 06:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:04:28 UTC to 2016-06-28 07:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:24:28 UTC to 2016-06-28 07:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:44:28 UTC to 2016-06-28 07:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:04:28 UTC to 2016-06-28 08:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:24:28 UTC to 2016-06-28 08:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:44:28 UTC to 2016-06-28 08:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:04:28 UTC to 2016-06-28 09:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:24:28 UTC to 2016-06-28 09:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:44:28 UTC to 2016-06-28 09:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:04:28 UTC to 2016-06-28 10:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:24:28 UTC to 2016-06-28 10:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:44:28 UTC to 2016-06-28 10:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:04:28 UTC to 2016-06-28 11:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:24:28 UTC to 2016-06-28 11:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:44:28 UTC to 2016-06-28 11:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 12:04:28 UTC to 2016-06-28 12:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 12:24:28 UTC to 2016-06-28 12:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:21:41 UTC to 2016-06-30 20:22:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:31:41 UTC to 2016-06-30 20:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:51:41 UTC to 2016-06-30 20:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:11:41 UTC to 2016-06-30 21:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:31:41 UTC to 2016-06-30 21:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:51:41 UTC to 2016-06-30 21:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:11:41 UTC to 2016-06-30 22:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:31:41 UTC to 2016-06-30 22:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:51:41 UTC to 2016-06-30 22:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:11:41 UTC to 2016-06-30 23:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:31:41 UTC to 2016-06-30 23:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:51:41 UTC to 2016-06-30 23:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:11:41 UTC to 2016-07-01 00:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:31:41 UTC to 2016-07-01 00:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:51:41 UTC to 2016-07-01 00:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:11:41 UTC to 2016-07-01 01:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:31:40 UTC to 2016-07-01 01:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:51:41 UTC to 2016-07-01 01:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:11:40 UTC to 2016-07-01 02:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:31:40 UTC to 2016-07-01 02:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:51:40 UTC to 2016-07-01 02:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:11:41 UTC to 2016-07-01 03:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:31:40 UTC to 2016-07-01 03:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:51:40 UTC to 2016-07-01 03:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:11:40 UTC to 2016-07-01 04:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:31:40 UTC to 2016-07-01 04:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:51:40 UTC to 2016-07-01 04:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:11:40 UTC to 2016-07-01 05:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:31:40 UTC to 2016-07-01 05:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:51:40 UTC to 2016-07-01 05:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:11:40 UTC to 2016-07-01 06:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:31:40 UTC to 2016-07-01 06:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:51:40 UTC to 2016-07-01 06:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:11:40 UTC to 2016-07-01 07:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:31:40 UTC to 2016-07-01 07:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:51:40 UTC to 2016-07-01 07:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-01 08:14:58 UTC to 2016-06-01 08:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 08:35:02 UTC to 2016-06-01 08:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 08:54:58 UTC to 2016-06-01 08:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:14:58 UTC to 2016-06-01 09:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:34:58 UTC to 2016-06-01 09:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:54:58 UTC to 2016-06-01 09:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:14:58 UTC to 2016-06-01 10:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:34:58 UTC to 2016-06-01 10:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:54:58 UTC to 2016-06-01 10:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:14:58 UTC to 2016-06-01 11:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:34:58 UTC to 2016-06-01 11:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:54:58 UTC to 2016-06-01 11:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:14:58 UTC to 2016-06-01 12:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:34:58 UTC to 2016-06-01 12:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:54:58 UTC to 2016-06-01 12:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:14:57 UTC to 2016-06-01 13:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:34:58 UTC to 2016-06-01 13:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:54:58 UTC to 2016-06-01 13:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:14:57 UTC to 2016-06-01 14:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:34:57 UTC to 2016-06-01 14:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:54:57 UTC to 2016-06-01 14:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:14:59 UTC to 2016-06-01 15:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:34:57 UTC to 2016-06-01 15:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:54:57 UTC to 2016-06-01 15:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:14:59 UTC to 2016-06-01 16:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:34:58 UTC to 2016-06-01 16:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:54:57 UTC to 2016-06-01 16:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:14:57 UTC to 2016-06-01 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:34:57 UTC to 2016-06-01 17:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:54:57 UTC to 2016-06-01 17:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:14:58 UTC to 2016-06-01 18:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:34:57 UTC to 2016-06-01 18:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:54:57 UTC to 2016-06-01 18:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:14:57 UTC to 2016-06-01 19:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:34:57 UTC to 2016-06-01 19:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:54:57 UTC to 2016-06-01 19:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:14:58 UTC to 2016-06-01 20:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:34:57 UTC to 2016-06-01 20:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:54:57 UTC to 2016-06-01 20:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:14:57 UTC to 2016-06-01 21:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:34:58 UTC to 2016-06-01 21:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:54:58 UTC to 2016-06-01 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:14:58 UTC to 2016-06-01 22:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:34:57 UTC to 2016-06-01 22:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:55:00 UTC to 2016-06-01 22:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:14:57 UTC to 2016-06-01 23:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:34:57 UTC to 2016-06-01 23:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:54:57 UTC to 2016-06-01 23:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:14:57 UTC to 2016-06-02 00:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:34:57 UTC to 2016-06-02 00:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:54:57 UTC to 2016-06-02 00:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:14:57 UTC to 2016-06-02 01:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:34:57 UTC to 2016-06-02 01:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:55:00 UTC to 2016-06-02 01:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:14:57 UTC to 2016-06-02 02:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:34:57 UTC to 2016-06-02 02:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:54:57 UTC to 2016-06-02 02:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:14:57 UTC to 2016-06-02 03:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:34:57 UTC to 2016-06-02 03:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:54:57 UTC to 2016-06-02 03:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:14:57 UTC to 2016-06-02 04:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:34:57 UTC to 2016-06-02 04:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:54:57 UTC to 2016-06-02 04:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:14:57 UTC to 2016-06-02 05:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:34:57 UTC to 2016-06-02 05:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:54:57 UTC to 2016-06-02 05:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:14:57 UTC to 2016-06-02 06:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:34:57 UTC to 2016-06-02 06:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:54:57 UTC to 2016-06-02 06:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:14:57 UTC to 2016-06-02 07:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:34:57 UTC to 2016-06-02 07:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:54:57 UTC to 2016-06-02 07:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:14:57 UTC to 2016-06-02 08:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:34:57 UTC to 2016-06-02 08:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:54:57 UTC to 2016-06-02 08:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:14:57 UTC to 2016-06-02 09:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:34:57 UTC to 2016-06-02 09:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:54:57 UTC to 2016-06-02 09:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:14:57 UTC to 2016-06-02 10:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:34:57 UTC to 2016-06-02 10:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:54:57 UTC to 2016-06-02 10:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:14:57 UTC to 2016-06-02 11:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:34:57 UTC to 2016-06-02 11:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:54:57 UTC to 2016-06-02 11:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:14:57 UTC to 2016-06-02 12:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:34:57 UTC to 2016-06-02 12:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:54:57 UTC to 2016-06-02 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:15:04 UTC to 2016-06-02 13:15:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:34:57 UTC to 2016-06-02 13:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:54:57 UTC to 2016-06-02 13:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:14:57 UTC to 2016-06-02 14:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:34:57 UTC to 2016-06-02 14:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:54:57 UTC to 2016-06-02 14:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:14:57 UTC to 2016-06-02 15:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:34:57 UTC to 2016-06-02 15:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:54:56 UTC to 2016-06-02 15:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:14:56 UTC to 2016-06-02 16:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:34:56 UTC to 2016-06-02 16:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:54:56 UTC to 2016-06-02 16:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:14:57 UTC to 2016-06-02 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:34:57 UTC to 2016-06-02 17:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:54:57 UTC to 2016-06-02 17:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:14:56 UTC to 2016-06-02 18:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:34:57 UTC to 2016-06-02 18:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:54:56 UTC to 2016-06-02 18:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:14:57 UTC to 2016-06-02 19:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:34:57 UTC to 2016-06-02 19:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:54:56 UTC to 2016-06-02 19:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 20:34:56 UTC to 2016-06-02 20:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 20:54:56 UTC to 2016-06-02 20:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:14:58 UTC to 2016-06-02 21:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:34:56 UTC to 2016-06-02 21:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:54:56 UTC to 2016-06-02 21:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:14:59 UTC to 2016-06-02 22:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:34:57 UTC to 2016-06-02 22:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:54:56 UTC to 2016-06-02 22:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:14:56 UTC to 2016-06-02 23:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:34:56 UTC to 2016-06-02 23:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:54:56 UTC to 2016-06-02 23:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:14:56 UTC to 2016-06-03 00:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:34:56 UTC to 2016-06-03 00:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:54:56 UTC to 2016-06-03 00:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:14:57 UTC to 2016-06-03 01:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:34:56 UTC to 2016-06-03 01:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:54:56 UTC to 2016-06-03 01:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:14:56 UTC to 2016-06-03 02:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:34:56 UTC to 2016-06-03 02:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:54:56 UTC to 2016-06-03 02:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:14:56 UTC to 2016-06-03 03:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:34:56 UTC to 2016-06-03 03:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:54:56 UTC to 2016-06-03 03:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:14:56 UTC to 2016-06-03 04:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:34:56 UTC to 2016-06-03 04:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:54:56 UTC to 2016-06-03 04:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:14:56 UTC to 2016-06-03 05:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:34:58 UTC to 2016-06-03 05:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:54:56 UTC to 2016-06-03 05:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:14:56 UTC to 2016-06-03 06:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:34:56 UTC to 2016-06-03 06:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:54:56 UTC to 2016-06-03 06:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:14:56 UTC to 2016-06-03 07:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:34:56 UTC to 2016-06-03 07:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:54:56 UTC to 2016-06-03 07:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:14:56 UTC to 2016-06-03 08:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:34:56 UTC to 2016-06-03 08:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:54:56 UTC to 2016-06-03 08:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:14:56 UTC to 2016-06-03 09:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:34:56 UTC to 2016-06-03 09:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:54:56 UTC to 2016-06-03 09:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:14:56 UTC to 2016-06-03 10:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:34:56 UTC to 2016-06-03 10:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:54:56 UTC to 2016-06-03 10:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:14:56 UTC to 2016-06-03 11:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:34:56 UTC to 2016-06-03 11:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:54:56 UTC to 2016-06-03 11:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:14:56 UTC to 2016-06-03 12:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:34:56 UTC to 2016-06-03 12:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:55:14 UTC to 2016-06-03 12:55:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:14:56 UTC to 2016-06-03 13:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:34:56 UTC to 2016-06-03 13:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:54:56 UTC to 2016-06-03 13:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 14:34:56 UTC to 2016-06-03 14:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 14:54:56 UTC to 2016-06-03 14:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:14:56 UTC to 2016-06-03 15:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:34:56 UTC to 2016-06-03 15:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:54:56 UTC to 2016-06-03 15:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:14:56 UTC to 2016-06-03 16:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:34:56 UTC to 2016-06-03 16:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:54:56 UTC to 2016-06-03 16:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:14:57 UTC to 2016-06-03 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:35:03 UTC to 2016-06-03 17:35:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:54:56 UTC to 2016-06-03 17:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:14:56 UTC to 2016-06-03 18:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:34:56 UTC to 2016-06-03 18:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:54:56 UTC to 2016-06-03 18:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:14:56 UTC to 2016-06-03 19:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:34:56 UTC to 2016-06-03 19:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:54:56 UTC to 2016-06-03 19:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:14:56 UTC to 2016-06-03 20:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:34:56 UTC to 2016-06-03 20:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:54:55 UTC to 2016-06-03 20:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:14:55 UTC to 2016-06-03 21:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:34:55 UTC to 2016-06-03 21:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:54:58 UTC to 2016-06-03 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:14:56 UTC to 2016-06-03 22:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:34:59 UTC to 2016-06-03 22:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:54:55 UTC to 2016-06-03 22:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:14:55 UTC to 2016-06-03 23:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:34:55 UTC to 2016-06-03 23:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:54:56 UTC to 2016-06-03 23:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:14:55 UTC to 2016-06-04 00:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:34:55 UTC to 2016-06-04 00:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:54:56 UTC to 2016-06-04 00:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:14:55 UTC to 2016-06-04 01:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:34:56 UTC to 2016-06-04 01:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:54:56 UTC to 2016-06-04 01:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:14:55 UTC to 2016-06-04 02:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:34:56 UTC to 2016-06-04 02:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:54:55 UTC to 2016-06-04 02:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:14:55 UTC to 2016-06-04 03:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:34:55 UTC to 2016-06-04 03:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:54:56 UTC to 2016-06-04 03:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:14:55 UTC to 2016-06-04 04:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:34:55 UTC to 2016-06-04 04:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:54:55 UTC to 2016-06-04 04:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:14:55 UTC to 2016-06-04 05:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:34:55 UTC to 2016-06-04 05:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:54:55 UTC to 2016-06-04 05:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:14:55 UTC to 2016-06-04 06:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:34:55 UTC to 2016-06-04 06:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:54:55 UTC to 2016-06-04 06:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:14:55 UTC to 2016-06-04 07:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:34:55 UTC to 2016-06-04 07:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:54:57 UTC to 2016-06-04 07:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:14:55 UTC to 2016-06-04 08:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:34:55 UTC to 2016-06-04 08:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:54:55 UTC to 2016-06-04 08:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:14:55 UTC to 2016-06-04 09:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:34:55 UTC to 2016-06-04 09:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:54:55 UTC to 2016-06-04 09:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:14:55 UTC to 2016-06-04 10:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:34:55 UTC to 2016-06-04 10:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:54:55 UTC to 2016-06-04 10:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:14:55 UTC to 2016-06-04 11:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:34:55 UTC to 2016-06-04 11:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:54:55 UTC to 2016-06-04 11:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:14:55 UTC to 2016-06-04 12:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:34:55 UTC to 2016-06-04 12:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:54:55 UTC to 2016-06-04 12:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:14:55 UTC to 2016-06-04 13:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:34:55 UTC to 2016-06-04 13:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:54:55 UTC to 2016-06-04 13:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:14:55 UTC to 2016-06-04 14:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:34:55 UTC to 2016-06-04 14:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:54:55 UTC to 2016-06-04 14:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:14:55 UTC to 2016-06-04 15:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:34:55 UTC to 2016-06-04 15:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:54:55 UTC to 2016-06-04 15:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:14:55 UTC to 2016-06-04 16:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:34:55 UTC to 2016-06-04 16:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:54:55 UTC to 2016-06-04 16:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:14:55 UTC to 2016-06-04 17:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:34:55 UTC to 2016-06-04 17:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:54:55 UTC to 2016-06-04 17:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:14:55 UTC to 2016-06-04 18:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:34:55 UTC to 2016-06-04 18:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:54:57 UTC to 2016-06-04 18:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:14:55 UTC to 2016-06-04 19:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:34:55 UTC to 2016-06-04 19:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:54:55 UTC to 2016-06-04 19:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:14:55 UTC to 2016-06-04 20:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:34:55 UTC to 2016-06-04 20:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:54:55 UTC to 2016-06-04 20:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:14:55 UTC to 2016-06-04 21:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:35:05 UTC to 2016-06-04 21:35:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:54:55 UTC to 2016-06-04 21:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:14:55 UTC to 2016-06-04 22:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:34:55 UTC to 2016-06-04 22:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:54:54 UTC to 2016-06-04 22:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:14:54 UTC to 2016-06-04 23:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:34:55 UTC to 2016-06-04 23:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:54:55 UTC to 2016-06-04 23:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:14:55 UTC to 2016-06-05 00:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:34:54 UTC to 2016-06-05 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:54:54 UTC to 2016-06-05 00:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:14:55 UTC to 2016-06-05 01:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:34:54 UTC to 2016-06-05 01:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:54:55 UTC to 2016-06-05 01:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:14:54 UTC to 2016-06-05 02:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:34:54 UTC to 2016-06-05 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:54:54 UTC to 2016-06-05 02:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:14:54 UTC to 2016-06-05 03:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:34:55 UTC to 2016-06-05 03:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:54:54 UTC to 2016-06-05 03:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:14:54 UTC to 2016-06-05 04:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:34:55 UTC to 2016-06-05 04:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:54:54 UTC to 2016-06-05 04:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:14:54 UTC to 2016-06-05 05:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:34:54 UTC to 2016-06-05 05:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:54:54 UTC to 2016-06-05 05:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:14:54 UTC to 2016-06-05 06:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:34:54 UTC to 2016-06-05 06:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:54:55 UTC to 2016-06-05 06:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 07:14:54 UTC to 2016-06-05 07:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 07:34:54 UTC to 2016-06-05 07:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:14:54 UTC to 2016-06-05 08:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:34:54 UTC to 2016-06-05 08:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:54:54 UTC to 2016-06-05 08:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:14:54 UTC to 2016-06-05 09:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:34:55 UTC to 2016-06-05 09:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:54:54 UTC to 2016-06-05 09:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:14:54 UTC to 2016-06-05 10:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:34:55 UTC to 2016-06-05 10:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:54:59 UTC to 2016-06-05 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:14:54 UTC to 2016-06-05 11:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:34:54 UTC to 2016-06-05 11:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:54:54 UTC to 2016-06-05 11:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:14:54 UTC to 2016-06-05 12:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:34:54 UTC to 2016-06-05 12:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:54:57 UTC to 2016-06-05 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 13:14:54 UTC to 2016-06-05 13:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 13:54:54 UTC to 2016-06-05 13:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:14:54 UTC to 2016-06-05 14:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:34:54 UTC to 2016-06-05 14:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:54:54 UTC to 2016-06-05 14:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:14:54 UTC to 2016-06-05 15:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:34:54 UTC to 2016-06-05 15:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:54:54 UTC to 2016-06-05 15:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:14:54 UTC to 2016-06-05 16:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:34:54 UTC to 2016-06-05 16:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:54:54 UTC to 2016-06-05 16:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:14:54 UTC to 2016-06-05 17:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:34:54 UTC to 2016-06-05 17:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:54:54 UTC to 2016-06-05 17:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:14:54 UTC to 2016-06-05 18:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:34:54 UTC to 2016-06-05 18:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:54:54 UTC to 2016-06-05 18:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:14:54 UTC to 2016-06-05 19:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:34:54 UTC to 2016-06-05 19:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:54:54 UTC to 2016-06-05 19:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:14:54 UTC to 2016-06-05 20:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:34:54 UTC to 2016-06-05 20:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:54:54 UTC to 2016-06-05 20:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:14:54 UTC to 2016-06-05 21:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:34:54 UTC to 2016-06-05 21:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:54:54 UTC to 2016-06-05 21:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:14:54 UTC to 2016-06-05 22:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:34:54 UTC to 2016-06-05 22:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:54:54 UTC to 2016-06-05 22:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:14:54 UTC to 2016-06-05 23:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:34:54 UTC to 2016-06-05 23:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:54:54 UTC to 2016-06-05 23:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:14:54 UTC to 2016-06-06 00:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:34:54 UTC to 2016-06-06 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:54:54 UTC to 2016-06-06 00:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:14:54 UTC to 2016-06-06 01:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:34:54 UTC to 2016-06-06 01:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:54:54 UTC to 2016-06-06 01:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:14:53 UTC to 2016-06-06 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:34:54 UTC to 2016-06-06 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:54:54 UTC to 2016-06-06 02:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 03:14:54 UTC to 2016-06-06 03:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 03:54:54 UTC to 2016-06-06 03:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:14:53 UTC to 2016-06-06 04:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:34:53 UTC to 2016-06-06 04:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:54:53 UTC to 2016-06-06 04:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:14:53 UTC to 2016-06-06 05:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:34:53 UTC to 2016-06-06 05:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:54:53 UTC to 2016-06-06 05:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:14:53 UTC to 2016-06-06 06:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:34:53 UTC to 2016-06-06 06:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:54:53 UTC to 2016-06-06 06:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:14:53 UTC to 2016-06-06 07:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:34:53 UTC to 2016-06-06 07:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:54:53 UTC to 2016-06-06 07:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:14:53 UTC to 2016-06-06 08:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:34:53 UTC to 2016-06-06 08:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:54:53 UTC to 2016-06-06 08:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:14:55 UTC to 2016-06-06 09:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:34:53 UTC to 2016-06-06 09:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:54:53 UTC to 2016-06-06 09:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:14:53 UTC to 2016-06-06 10:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:34:53 UTC to 2016-06-06 10:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:54:53 UTC to 2016-06-06 10:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:14:54 UTC to 2016-06-06 11:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:34:53 UTC to 2016-06-06 11:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:54:53 UTC to 2016-06-06 11:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:14:53 UTC to 2016-06-06 12:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:34:53 UTC to 2016-06-06 12:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:54:54 UTC to 2016-06-06 12:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:14:53 UTC to 2016-06-06 13:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:34:53 UTC to 2016-06-06 13:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:54:53 UTC to 2016-06-06 13:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:14:53 UTC to 2016-06-06 14:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:34:53 UTC to 2016-06-06 14:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:54:53 UTC to 2016-06-06 14:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:14:53 UTC to 2016-06-06 15:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:34:53 UTC to 2016-06-06 15:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:54:53 UTC to 2016-06-06 15:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:14:53 UTC to 2016-06-06 16:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:34:53 UTC to 2016-06-06 16:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:54:53 UTC to 2016-06-06 16:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:14:53 UTC to 2016-06-06 17:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:34:53 UTC to 2016-06-06 17:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:54:53 UTC to 2016-06-06 17:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:14:53 UTC to 2016-06-06 18:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:34:53 UTC to 2016-06-06 18:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:54:53 UTC to 2016-06-06 18:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:14:53 UTC to 2016-06-06 19:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:34:53 UTC to 2016-06-06 19:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:54:53 UTC to 2016-06-06 19:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:14:53 UTC to 2016-06-06 20:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:34:53 UTC to 2016-06-06 20:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:54:53 UTC to 2016-06-06 20:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:14:53 UTC to 2016-06-06 21:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:34:53 UTC to 2016-06-06 21:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:54:53 UTC to 2016-06-06 21:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 22:14:53 UTC to 2016-06-06 22:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 22:35:05 UTC to 2016-06-06 22:35:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:15:01 UTC to 2016-06-07 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:34:56 UTC to 2016-06-07 00:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:54:57 UTC to 2016-06-07 00:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 01:34:53 UTC to 2016-06-07 01:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 01:54:55 UTC to 2016-06-07 01:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:14:53 UTC to 2016-06-07 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:34:53 UTC to 2016-06-07 02:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:54:53 UTC to 2016-06-07 02:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:14:53 UTC to 2016-06-07 03:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:34:53 UTC to 2016-06-07 03:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:54:53 UTC to 2016-06-07 03:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:14:52 UTC to 2016-06-07 04:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:34:53 UTC to 2016-06-07 04:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:54:53 UTC to 2016-06-07 04:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:14:52 UTC to 2016-06-07 05:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:34:53 UTC to 2016-06-07 05:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:54:52 UTC to 2016-06-07 05:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:14:52 UTC to 2016-06-07 06:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:34:52 UTC to 2016-06-07 06:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:54:52 UTC to 2016-06-07 06:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:14:52 UTC to 2016-06-07 07:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:34:52 UTC to 2016-06-07 07:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:54:52 UTC to 2016-06-07 07:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:14:52 UTC to 2016-06-07 08:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:34:52 UTC to 2016-06-07 08:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:54:52 UTC to 2016-06-07 08:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:14:52 UTC to 2016-06-07 09:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:34:52 UTC to 2016-06-07 09:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:54:52 UTC to 2016-06-07 09:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:14:52 UTC to 2016-06-07 10:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:34:52 UTC to 2016-06-07 10:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:54:53 UTC to 2016-06-07 10:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:14:52 UTC to 2016-06-07 11:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:34:52 UTC to 2016-06-07 11:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:54:52 UTC to 2016-06-07 11:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:14:52 UTC to 2016-06-07 12:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:34:52 UTC to 2016-06-07 12:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:54:57 UTC to 2016-06-07 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:14:52 UTC to 2016-06-07 13:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:34:52 UTC to 2016-06-07 13:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:54:52 UTC to 2016-06-07 13:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:14:52 UTC to 2016-06-07 14:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:34:52 UTC to 2016-06-07 14:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:54:52 UTC to 2016-06-07 14:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:14:53 UTC to 2016-06-07 15:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:34:52 UTC to 2016-06-07 15:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:54:52 UTC to 2016-06-07 15:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:14:52 UTC to 2016-06-07 16:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:34:53 UTC to 2016-06-07 16:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:54:52 UTC to 2016-06-07 16:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:14:52 UTC to 2016-06-07 17:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:36:08 UTC to 2016-06-07 17:36:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:54:52 UTC to 2016-06-07 17:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:14:52 UTC to 2016-06-07 18:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:34:52 UTC to 2016-06-07 18:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:54:53 UTC to 2016-06-07 18:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:14:52 UTC to 2016-06-07 19:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:34:52 UTC to 2016-06-07 19:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:54:52 UTC to 2016-06-07 19:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:14:52 UTC to 2016-06-07 20:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:34:52 UTC to 2016-06-07 20:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:54:52 UTC to 2016-06-07 20:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:14:52 UTC to 2016-06-07 21:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:34:52 UTC to 2016-06-07 21:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:54:52 UTC to 2016-06-07 21:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:14:52 UTC to 2016-06-07 22:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:34:52 UTC to 2016-06-07 22:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:54:52 UTC to 2016-06-07 22:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:14:52 UTC to 2016-06-07 23:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:34:53 UTC to 2016-06-07 23:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:55:06 UTC to 2016-06-07 23:55:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:14:52 UTC to 2016-06-08 00:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:34:54 UTC to 2016-06-08 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:54:52 UTC to 2016-06-08 00:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:14:52 UTC to 2016-06-08 01:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:34:55 UTC to 2016-06-08 01:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:54:52 UTC to 2016-06-08 01:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:14:53 UTC to 2016-06-08 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:34:54 UTC to 2016-06-08 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:55:08 UTC to 2016-06-08 02:55:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:14:52 UTC to 2016-06-08 03:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:34:52 UTC to 2016-06-08 03:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:54:52 UTC to 2016-06-08 03:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:14:52 UTC to 2016-06-08 04:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:34:52 UTC to 2016-06-08 04:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:54:52 UTC to 2016-06-08 04:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:14:52 UTC to 2016-06-08 05:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:34:52 UTC to 2016-06-08 05:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:54:52 UTC to 2016-06-08 05:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:14:52 UTC to 2016-06-08 06:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:34:52 UTC to 2016-06-08 06:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:54:52 UTC to 2016-06-08 06:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:14:52 UTC to 2016-06-08 07:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:34:52 UTC to 2016-06-08 07:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:54:52 UTC to 2016-06-08 07:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:14:52 UTC to 2016-06-08 08:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:34:52 UTC to 2016-06-08 08:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:54:52 UTC to 2016-06-08 08:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:14:51 UTC to 2016-06-08 09:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:34:52 UTC to 2016-06-08 09:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:54:51 UTC to 2016-06-08 09:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:14:51 UTC to 2016-06-08 10:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:34:51 UTC to 2016-06-08 10:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:54:51 UTC to 2016-06-08 10:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:14:51 UTC to 2016-06-08 11:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:34:51 UTC to 2016-06-08 11:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:54:51 UTC to 2016-06-08 11:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:14:51 UTC to 2016-06-08 12:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:34:51 UTC to 2016-06-08 12:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:54:51 UTC to 2016-06-08 12:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:14:51 UTC to 2016-06-08 13:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:34:51 UTC to 2016-06-08 13:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:54:51 UTC to 2016-06-08 13:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:14:51 UTC to 2016-06-08 14:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:34:51 UTC to 2016-06-08 14:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:54:51 UTC to 2016-06-08 14:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:14:51 UTC to 2016-06-08 15:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:34:51 UTC to 2016-06-08 15:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:54:51 UTC to 2016-06-08 15:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:14:51 UTC to 2016-06-08 16:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:34:51 UTC to 2016-06-08 16:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:54:51 UTC to 2016-06-08 16:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:14:51 UTC to 2016-06-08 17:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:34:51 UTC to 2016-06-08 17:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:54:51 UTC to 2016-06-08 17:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:14:51 UTC to 2016-06-08 18:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:34:51 UTC to 2016-06-08 18:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:54:51 UTC to 2016-06-08 18:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:14:51 UTC to 2016-06-08 19:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:34:51 UTC to 2016-06-08 19:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:54:51 UTC to 2016-06-08 19:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:14:51 UTC to 2016-06-08 20:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:34:52 UTC to 2016-06-08 20:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:54:51 UTC to 2016-06-08 20:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:14:51 UTC to 2016-06-08 21:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:34:51 UTC to 2016-06-08 21:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:54:51 UTC to 2016-06-08 21:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:14:51 UTC to 2016-06-08 22:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:34:51 UTC to 2016-06-08 22:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:54:51 UTC to 2016-06-08 22:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:14:51 UTC to 2016-06-08 23:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:34:51 UTC to 2016-06-08 23:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:54:51 UTC to 2016-06-08 23:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:14:51 UTC to 2016-06-09 00:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:34:51 UTC to 2016-06-09 00:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:54:51 UTC to 2016-06-09 00:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:14:51 UTC to 2016-06-09 01:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:34:51 UTC to 2016-06-09 01:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:54:51 UTC to 2016-06-09 01:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:14:51 UTC to 2016-06-09 02:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:34:51 UTC to 2016-06-09 02:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:54:51 UTC to 2016-06-09 02:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:14:51 UTC to 2016-06-09 03:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:34:51 UTC to 2016-06-09 03:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:54:51 UTC to 2016-06-09 03:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:14:51 UTC to 2016-06-09 04:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:34:51 UTC to 2016-06-09 04:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:54:51 UTC to 2016-06-09 04:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:14:51 UTC to 2016-06-09 05:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:34:51 UTC to 2016-06-09 05:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:54:51 UTC to 2016-06-09 05:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:14:51 UTC to 2016-06-09 06:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:34:51 UTC to 2016-06-09 06:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:54:51 UTC to 2016-06-09 06:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:14:51 UTC to 2016-06-09 07:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:34:51 UTC to 2016-06-09 07:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:54:51 UTC to 2016-06-09 07:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:14:51 UTC to 2016-06-09 08:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:34:51 UTC to 2016-06-09 08:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:54:51 UTC to 2016-06-09 08:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:14:51 UTC to 2016-06-09 09:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:34:51 UTC to 2016-06-09 09:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:54:51 UTC to 2016-06-09 09:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:14:50 UTC to 2016-06-09 10:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:34:51 UTC to 2016-06-09 10:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:54:51 UTC to 2016-06-09 10:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:14:51 UTC to 2016-06-09 11:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:34:51 UTC to 2016-06-09 11:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:54:51 UTC to 2016-06-09 11:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:14:50 UTC to 2016-06-09 12:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:34:50 UTC to 2016-06-09 12:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:54:50 UTC to 2016-06-09 12:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:14:50 UTC to 2016-06-09 13:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:34:50 UTC to 2016-06-09 13:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:54:50 UTC to 2016-06-09 13:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:14:50 UTC to 2016-06-09 14:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:34:50 UTC to 2016-06-09 14:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:54:51 UTC to 2016-06-09 14:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:14:51 UTC to 2016-06-09 15:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:34:51 UTC to 2016-06-09 15:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:54:50 UTC to 2016-06-09 15:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:14:50 UTC to 2016-06-09 16:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:34:50 UTC to 2016-06-09 16:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:54:50 UTC to 2016-06-09 16:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:14:50 UTC to 2016-06-09 17:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:34:50 UTC to 2016-06-09 17:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:54:50 UTC to 2016-06-09 17:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:14:50 UTC to 2016-06-09 18:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:34:50 UTC to 2016-06-09 18:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:54:50 UTC to 2016-06-09 18:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:14:51 UTC to 2016-06-09 19:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:34:50 UTC to 2016-06-09 19:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:54:50 UTC to 2016-06-09 19:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:14:50 UTC to 2016-06-09 20:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:34:50 UTC to 2016-06-09 20:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:54:50 UTC to 2016-06-09 20:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:14:50 UTC to 2016-06-09 21:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:34:50 UTC to 2016-06-09 21:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:54:50 UTC to 2016-06-09 21:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:14:50 UTC to 2016-06-09 22:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:34:50 UTC to 2016-06-09 22:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:54:50 UTC to 2016-06-09 22:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:14:50 UTC to 2016-06-09 23:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:34:50 UTC to 2016-06-09 23:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:54:50 UTC to 2016-06-09 23:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:14:50 UTC to 2016-06-10 00:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:34:50 UTC to 2016-06-10 00:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:54:50 UTC to 2016-06-10 00:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:14:50 UTC to 2016-06-10 01:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:34:50 UTC to 2016-06-10 01:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:54:50 UTC to 2016-06-10 01:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:14:50 UTC to 2016-06-10 02:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:34:50 UTC to 2016-06-10 02:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:54:50 UTC to 2016-06-10 02:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:14:50 UTC to 2016-06-10 03:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:34:50 UTC to 2016-06-10 03:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:54:50 UTC to 2016-06-10 03:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:14:50 UTC to 2016-06-10 04:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:34:50 UTC to 2016-06-10 04:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:54:50 UTC to 2016-06-10 04:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:14:50 UTC to 2016-06-10 05:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:34:50 UTC to 2016-06-10 05:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:54:50 UTC to 2016-06-10 05:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:14:50 UTC to 2016-06-10 06:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:34:50 UTC to 2016-06-10 06:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:54:50 UTC to 2016-06-10 06:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:14:50 UTC to 2016-06-10 07:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:34:50 UTC to 2016-06-10 07:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:54:50 UTC to 2016-06-10 07:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:14:50 UTC to 2016-06-10 08:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:34:50 UTC to 2016-06-10 08:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:54:50 UTC to 2016-06-10 08:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:14:50 UTC to 2016-06-10 09:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:34:50 UTC to 2016-06-10 09:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:54:50 UTC to 2016-06-10 09:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:14:50 UTC to 2016-06-10 10:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:34:50 UTC to 2016-06-10 10:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:54:50 UTC to 2016-06-10 10:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:14:50 UTC to 2016-06-10 11:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:34:50 UTC to 2016-06-10 11:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:54:50 UTC to 2016-06-10 11:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:14:50 UTC to 2016-06-10 12:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:34:50 UTC to 2016-06-10 12:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:54:50 UTC to 2016-06-10 12:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:14:50 UTC to 2016-06-10 13:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:34:50 UTC to 2016-06-10 13:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:54:50 UTC to 2016-06-10 13:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:14:49 UTC to 2016-06-10 14:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:34:49 UTC to 2016-06-10 14:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:54:50 UTC to 2016-06-10 14:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:14:50 UTC to 2016-06-10 15:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:34:49 UTC to 2016-06-10 15:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:54:49 UTC to 2016-06-10 15:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:14:49 UTC to 2016-06-10 16:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:34:50 UTC to 2016-06-10 16:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:54:49 UTC to 2016-06-10 16:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:14:49 UTC to 2016-06-10 17:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:34:49 UTC to 2016-06-10 17:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:54:49 UTC to 2016-06-10 17:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:14:49 UTC to 2016-06-10 18:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:34:50 UTC to 2016-06-10 18:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:54:50 UTC to 2016-06-10 18:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:14:49 UTC to 2016-06-10 19:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:34:52 UTC to 2016-06-10 19:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:54:49 UTC to 2016-06-10 19:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:14:49 UTC to 2016-06-10 20:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:34:49 UTC to 2016-06-10 20:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:54:49 UTC to 2016-06-10 20:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:14:49 UTC to 2016-06-10 21:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:34:49 UTC to 2016-06-10 21:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:54:49 UTC to 2016-06-10 21:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:14:49 UTC to 2016-06-10 22:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:34:49 UTC to 2016-06-10 22:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:54:49 UTC to 2016-06-10 22:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:14:49 UTC to 2016-06-10 23:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:34:49 UTC to 2016-06-10 23:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:54:49 UTC to 2016-06-10 23:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:14:49 UTC to 2016-06-11 00:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:34:49 UTC to 2016-06-11 00:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:54:49 UTC to 2016-06-11 00:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:14:49 UTC to 2016-06-11 01:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:34:49 UTC to 2016-06-11 01:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:54:49 UTC to 2016-06-11 01:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:14:49 UTC to 2016-06-11 02:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:34:49 UTC to 2016-06-11 02:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:54:49 UTC to 2016-06-11 02:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:14:49 UTC to 2016-06-11 03:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:34:49 UTC to 2016-06-11 03:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:54:49 UTC to 2016-06-11 03:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:14:49 UTC to 2016-06-11 04:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:34:49 UTC to 2016-06-11 04:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:54:49 UTC to 2016-06-11 04:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:14:49 UTC to 2016-06-11 05:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:34:49 UTC to 2016-06-11 05:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:54:49 UTC to 2016-06-11 05:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:14:49 UTC to 2016-06-11 06:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:34:49 UTC to 2016-06-11 06:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:54:49 UTC to 2016-06-11 06:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:14:49 UTC to 2016-06-11 07:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:34:49 UTC to 2016-06-11 07:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:54:49 UTC to 2016-06-11 07:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:14:49 UTC to 2016-06-11 08:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:34:54 UTC to 2016-06-11 08:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:54:49 UTC to 2016-06-11 08:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:14:49 UTC to 2016-06-11 09:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:34:49 UTC to 2016-06-11 09:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:54:49 UTC to 2016-06-11 09:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:14:49 UTC to 2016-06-11 10:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:34:49 UTC to 2016-06-11 10:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:54:49 UTC to 2016-06-11 10:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:14:49 UTC to 2016-06-11 11:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:34:49 UTC to 2016-06-11 11:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:54:49 UTC to 2016-06-11 11:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:14:49 UTC to 2016-06-11 12:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:34:49 UTC to 2016-06-11 12:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:54:49 UTC to 2016-06-11 12:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:14:49 UTC to 2016-06-11 13:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:34:49 UTC to 2016-06-11 13:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:54:49 UTC to 2016-06-11 13:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:14:49 UTC to 2016-06-11 14:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:34:49 UTC to 2016-06-11 14:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:54:49 UTC to 2016-06-11 14:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:14:49 UTC to 2016-06-11 15:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:34:49 UTC to 2016-06-11 15:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:54:49 UTC to 2016-06-11 15:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:14:49 UTC to 2016-06-11 16:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:34:49 UTC to 2016-06-11 16:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:54:49 UTC to 2016-06-11 16:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:14:49 UTC to 2016-06-11 17:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:34:49 UTC to 2016-06-11 17:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:54:48 UTC to 2016-06-11 17:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:14:48 UTC to 2016-06-11 18:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:34:49 UTC to 2016-06-11 18:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:54:49 UTC to 2016-06-11 18:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:14:49 UTC to 2016-06-11 19:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:34:49 UTC to 2016-06-11 19:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:54:48 UTC to 2016-06-11 19:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:14:48 UTC to 2016-06-11 20:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:34:48 UTC to 2016-06-11 20:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:54:48 UTC to 2016-06-11 20:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:14:48 UTC to 2016-06-11 21:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:34:48 UTC to 2016-06-11 21:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:54:48 UTC to 2016-06-11 21:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:14:48 UTC to 2016-06-11 22:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:34:48 UTC to 2016-06-11 22:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:54:48 UTC to 2016-06-11 22:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:14:48 UTC to 2016-06-11 23:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:34:49 UTC to 2016-06-11 23:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:54:48 UTC to 2016-06-11 23:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:14:49 UTC to 2016-06-12 00:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:34:48 UTC to 2016-06-12 00:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:54:48 UTC to 2016-06-12 00:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:14:48 UTC to 2016-06-12 01:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:34:48 UTC to 2016-06-12 01:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:54:48 UTC to 2016-06-12 01:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:14:48 UTC to 2016-06-12 02:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:34:48 UTC to 2016-06-12 02:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:54:48 UTC to 2016-06-12 02:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:14:48 UTC to 2016-06-12 03:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:34:48 UTC to 2016-06-12 03:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:54:48 UTC to 2016-06-12 03:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 04:14:48 UTC to 2016-06-12 04:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 04:54:48 UTC to 2016-06-12 04:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 05:14:48 UTC to 2016-06-12 05:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 05:54:48 UTC to 2016-06-12 05:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:14:48 UTC to 2016-06-12 06:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:34:48 UTC to 2016-06-12 06:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:54:48 UTC to 2016-06-12 06:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:14:48 UTC to 2016-06-12 07:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:34:48 UTC to 2016-06-12 07:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:54:48 UTC to 2016-06-12 07:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 08:34:48 UTC to 2016-06-12 08:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 08:54:48 UTC to 2016-06-12 08:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:14:48 UTC to 2016-06-12 09:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:34:48 UTC to 2016-06-12 09:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:54:48 UTC to 2016-06-12 09:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 10:14:48 UTC to 2016-06-12 10:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 10:34:48 UTC to 2016-06-12 10:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:14:48 UTC to 2016-06-12 11:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:34:48 UTC to 2016-06-12 11:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:54:48 UTC to 2016-06-12 11:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:14:48 UTC to 2016-06-12 12:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:34:48 UTC to 2016-06-12 12:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:54:48 UTC to 2016-06-12 12:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:14:48 UTC to 2016-06-12 13:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:34:48 UTC to 2016-06-12 13:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:54:48 UTC to 2016-06-12 13:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:14:48 UTC to 2016-06-12 14:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:34:48 UTC to 2016-06-12 14:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:54:50 UTC to 2016-06-12 14:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:14:48 UTC to 2016-06-12 15:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:34:48 UTC to 2016-06-12 15:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:54:48 UTC to 2016-06-12 15:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 16:34:48 UTC to 2016-06-12 16:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 16:54:48 UTC to 2016-06-12 16:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:14:48 UTC to 2016-06-12 17:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:34:48 UTC to 2016-06-12 17:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:54:48 UTC to 2016-06-12 17:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:14:48 UTC to 2016-06-12 18:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:34:48 UTC to 2016-06-12 18:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:54:48 UTC to 2016-06-12 18:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:14:48 UTC to 2016-06-12 19:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:34:48 UTC to 2016-06-12 19:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:54:48 UTC to 2016-06-12 19:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 20:14:48 UTC to 2016-06-12 20:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 20:34:48 UTC to 2016-06-12 20:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:14:47 UTC to 2016-06-12 21:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:34:48 UTC to 2016-06-12 21:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:54:47 UTC to 2016-06-12 21:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:14:48 UTC to 2016-06-12 22:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:34:47 UTC to 2016-06-12 22:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:54:47 UTC to 2016-06-12 22:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:14:48 UTC to 2016-06-12 23:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:34:47 UTC to 2016-06-12 23:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:54:47 UTC to 2016-06-12 23:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:14:47 UTC to 2016-06-13 00:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:34:47 UTC to 2016-06-13 00:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:54:47 UTC to 2016-06-13 00:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 01:14:47 UTC to 2016-06-13 01:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 01:54:47 UTC to 2016-06-13 01:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:14:47 UTC to 2016-06-13 02:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:34:47 UTC to 2016-06-13 02:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:54:47 UTC to 2016-06-13 02:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 03:34:47 UTC to 2016-06-13 03:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 03:54:47 UTC to 2016-06-13 03:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:14:47 UTC to 2016-06-13 04:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:34:47 UTC to 2016-06-13 04:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:54:47 UTC to 2016-06-13 04:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:14:48 UTC to 2016-06-13 05:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:34:47 UTC to 2016-06-13 05:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:54:47 UTC to 2016-06-13 05:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:14:47 UTC to 2016-06-13 06:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:34:47 UTC to 2016-06-13 06:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:54:47 UTC to 2016-06-13 06:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:14:47 UTC to 2016-06-13 07:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:34:47 UTC to 2016-06-13 07:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:54:47 UTC to 2016-06-13 07:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:14:47 UTC to 2016-06-13 08:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:34:47 UTC to 2016-06-13 08:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:54:47 UTC to 2016-06-13 08:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:14:47 UTC to 2016-06-13 09:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:34:47 UTC to 2016-06-13 09:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:54:47 UTC to 2016-06-13 09:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:14:47 UTC to 2016-06-13 10:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:34:47 UTC to 2016-06-13 10:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:54:47 UTC to 2016-06-13 10:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:14:47 UTC to 2016-06-13 11:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:34:47 UTC to 2016-06-13 11:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:54:47 UTC to 2016-06-13 11:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:14:47 UTC to 2016-06-13 12:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:34:47 UTC to 2016-06-13 12:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:54:47 UTC to 2016-06-13 12:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:14:47 UTC to 2016-06-13 13:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:34:47 UTC to 2016-06-13 13:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:54:47 UTC to 2016-06-13 13:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 14:14:47 UTC to 2016-06-13 14:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 14:34:50 UTC to 2016-06-13 14:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:14:47 UTC to 2016-06-13 15:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:34:47 UTC to 2016-06-13 15:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:54:47 UTC to 2016-06-13 15:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:14:47 UTC to 2016-06-13 16:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:34:47 UTC to 2016-06-13 16:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:54:47 UTC to 2016-06-13 16:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:14:47 UTC to 2016-06-13 17:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:34:47 UTC to 2016-06-13 17:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:54:47 UTC to 2016-06-13 17:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:14:47 UTC to 2016-06-13 18:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:34:47 UTC to 2016-06-13 18:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:54:47 UTC to 2016-06-13 18:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:14:47 UTC to 2016-06-13 19:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:34:47 UTC to 2016-06-13 19:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:54:47 UTC to 2016-06-13 19:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:14:47 UTC to 2016-06-13 20:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:34:47 UTC to 2016-06-13 20:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:54:47 UTC to 2016-06-13 20:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:14:47 UTC to 2016-06-13 21:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:34:47 UTC to 2016-06-13 21:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:54:47 UTC to 2016-06-13 21:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:14:47 UTC to 2016-06-13 22:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:34:47 UTC to 2016-06-13 22:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:54:47 UTC to 2016-06-13 22:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:14:47 UTC to 2016-06-13 23:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:34:47 UTC to 2016-06-13 23:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:54:47 UTC to 2016-06-13 23:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:14:46 UTC to 2016-06-14 00:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:34:46 UTC to 2016-06-14 00:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:54:46 UTC to 2016-06-14 00:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:14:46 UTC to 2016-06-14 01:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:34:46 UTC to 2016-06-14 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:54:46 UTC to 2016-06-14 01:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:14:46 UTC to 2016-06-14 02:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:34:46 UTC to 2016-06-14 02:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:54:46 UTC to 2016-06-14 02:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:14:46 UTC to 2016-06-14 03:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:34:46 UTC to 2016-06-14 03:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:54:46 UTC to 2016-06-14 03:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:14:46 UTC to 2016-06-14 04:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:34:46 UTC to 2016-06-14 04:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:54:46 UTC to 2016-06-14 04:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:14:46 UTC to 2016-06-14 05:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:34:46 UTC to 2016-06-14 05:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:54:46 UTC to 2016-06-14 05:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:14:46 UTC to 2016-06-14 06:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:34:46 UTC to 2016-06-14 06:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:54:46 UTC to 2016-06-14 06:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:14:46 UTC to 2016-06-14 07:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:34:46 UTC to 2016-06-14 07:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:54:46 UTC to 2016-06-14 07:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:14:46 UTC to 2016-06-14 08:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:34:46 UTC to 2016-06-14 08:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:54:46 UTC to 2016-06-14 08:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:14:46 UTC to 2016-06-14 09:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:34:46 UTC to 2016-06-14 09:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:54:46 UTC to 2016-06-14 09:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:14:46 UTC to 2016-06-14 10:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:34:46 UTC to 2016-06-14 10:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:54:46 UTC to 2016-06-14 10:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:14:46 UTC to 2016-06-14 11:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:34:46 UTC to 2016-06-14 11:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:54:46 UTC to 2016-06-14 11:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:14:46 UTC to 2016-06-14 12:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:34:46 UTC to 2016-06-14 12:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:54:46 UTC to 2016-06-14 12:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:14:46 UTC to 2016-06-14 13:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:34:46 UTC to 2016-06-14 13:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:54:46 UTC to 2016-06-14 13:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:14:46 UTC to 2016-06-14 14:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:34:46 UTC to 2016-06-14 14:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:54:46 UTC to 2016-06-14 14:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:14:46 UTC to 2016-06-14 15:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:34:46 UTC to 2016-06-14 15:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:54:46 UTC to 2016-06-14 15:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:14:46 UTC to 2016-06-14 16:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:34:46 UTC to 2016-06-14 16:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:54:46 UTC to 2016-06-14 16:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:14:46 UTC to 2016-06-14 17:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:34:46 UTC to 2016-06-14 17:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:54:46 UTC to 2016-06-14 17:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:14:46 UTC to 2016-06-14 18:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:34:46 UTC to 2016-06-14 18:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:54:46 UTC to 2016-06-14 18:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:14:46 UTC to 2016-06-14 19:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:34:46 UTC to 2016-06-14 19:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:54:46 UTC to 2016-06-14 19:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:14:46 UTC to 2016-06-14 20:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:34:46 UTC to 2016-06-14 20:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:54:46 UTC to 2016-06-14 20:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:14:46 UTC to 2016-06-14 21:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:34:46 UTC to 2016-06-14 21:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:54:46 UTC to 2016-06-14 21:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:14:46 UTC to 2016-06-14 22:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:34:46 UTC to 2016-06-14 22:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:54:46 UTC to 2016-06-14 22:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:14:46 UTC to 2016-06-14 23:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:34:46 UTC to 2016-06-14 23:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:54:46 UTC to 2016-06-14 23:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:14:46 UTC to 2016-06-15 00:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:34:46 UTC to 2016-06-15 00:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:54:46 UTC to 2016-06-15 00:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:14:46 UTC to 2016-06-15 01:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:34:46 UTC to 2016-06-15 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:54:46 UTC to 2016-06-15 01:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:14:46 UTC to 2016-06-15 02:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:34:46 UTC to 2016-06-15 02:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:54:46 UTC to 2016-06-15 02:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:14:46 UTC to 2016-06-15 03:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:34:45 UTC to 2016-06-15 03:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:54:46 UTC to 2016-06-15 03:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:14:46 UTC to 2016-06-15 04:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:34:46 UTC to 2016-06-15 04:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:54:46 UTC to 2016-06-15 04:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:14:45 UTC to 2016-06-15 05:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:34:46 UTC to 2016-06-15 05:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:54:45 UTC to 2016-06-15 05:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:14:45 UTC to 2016-06-15 06:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:34:45 UTC to 2016-06-15 06:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:54:45 UTC to 2016-06-15 06:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:14:45 UTC to 2016-06-15 07:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:34:45 UTC to 2016-06-15 07:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:54:45 UTC to 2016-06-15 07:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:14:45 UTC to 2016-06-15 08:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:34:45 UTC to 2016-06-15 08:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:54:45 UTC to 2016-06-15 08:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:14:45 UTC to 2016-06-15 09:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:34:45 UTC to 2016-06-15 09:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:54:45 UTC to 2016-06-15 09:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:14:45 UTC to 2016-06-15 10:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:34:45 UTC to 2016-06-15 10:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:54:45 UTC to 2016-06-15 10:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:14:45 UTC to 2016-06-15 11:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:34:45 UTC to 2016-06-15 11:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:54:45 UTC to 2016-06-15 11:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:14:45 UTC to 2016-06-15 12:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:34:45 UTC to 2016-06-15 12:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:54:45 UTC to 2016-06-15 12:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:14:45 UTC to 2016-06-15 13:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:34:45 UTC to 2016-06-15 13:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:54:45 UTC to 2016-06-15 13:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:14:45 UTC to 2016-06-15 14:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:34:46 UTC to 2016-06-15 14:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:54:45 UTC to 2016-06-15 14:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:14:46 UTC to 2016-06-15 15:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:34:46 UTC to 2016-06-15 15:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:54:45 UTC to 2016-06-15 15:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:14:45 UTC to 2016-06-15 16:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:34:45 UTC to 2016-06-15 16:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:54:45 UTC to 2016-06-15 16:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:14:45 UTC to 2016-06-15 17:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:34:45 UTC to 2016-06-15 17:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:54:45 UTC to 2016-06-15 17:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:14:45 UTC to 2016-06-15 18:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:34:45 UTC to 2016-06-15 18:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:54:45 UTC to 2016-06-15 18:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:14:45 UTC to 2016-06-15 19:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:34:45 UTC to 2016-06-15 19:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:54:45 UTC to 2016-06-15 19:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:14:45 UTC to 2016-06-15 20:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:34:45 UTC to 2016-06-15 20:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:54:45 UTC to 2016-06-15 20:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:14:48 UTC to 2016-06-15 21:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:34:45 UTC to 2016-06-15 21:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:54:45 UTC to 2016-06-15 21:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:14:45 UTC to 2016-06-15 22:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:34:45 UTC to 2016-06-15 22:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:54:45 UTC to 2016-06-15 22:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:14:45 UTC to 2016-06-15 23:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:34:45 UTC to 2016-06-15 23:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:55:03 UTC to 2016-06-15 23:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:14:45 UTC to 2016-06-16 00:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:34:45 UTC to 2016-06-16 00:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:54:45 UTC to 2016-06-16 00:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:14:45 UTC to 2016-06-16 01:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:34:46 UTC to 2016-06-16 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:54:45 UTC to 2016-06-16 01:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:14:45 UTC to 2016-06-16 02:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:34:45 UTC to 2016-06-16 02:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:54:45 UTC to 2016-06-16 02:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:14:45 UTC to 2016-06-16 03:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:34:45 UTC to 2016-06-16 03:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:54:45 UTC to 2016-06-16 03:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:14:45 UTC to 2016-06-16 04:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:34:45 UTC to 2016-06-16 04:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:54:45 UTC to 2016-06-16 04:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:14:45 UTC to 2016-06-16 05:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:34:45 UTC to 2016-06-16 05:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:54:45 UTC to 2016-06-16 05:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:14:45 UTC to 2016-06-16 06:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:34:45 UTC to 2016-06-16 06:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:54:45 UTC to 2016-06-16 06:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:14:45 UTC to 2016-06-16 07:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:34:45 UTC to 2016-06-16 07:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:54:45 UTC to 2016-06-16 07:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:14:44 UTC to 2016-06-16 08:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:34:45 UTC to 2016-06-16 08:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:54:45 UTC to 2016-06-16 08:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:14:45 UTC to 2016-06-16 09:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:34:45 UTC to 2016-06-16 09:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:54:45 UTC to 2016-06-16 09:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:14:44 UTC to 2016-06-16 10:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:34:44 UTC to 2016-06-16 10:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:54:44 UTC to 2016-06-16 10:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:14:45 UTC to 2016-06-16 11:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:34:44 UTC to 2016-06-16 11:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:54:44 UTC to 2016-06-16 11:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:14:44 UTC to 2016-06-16 12:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:34:45 UTC to 2016-06-16 12:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:54:44 UTC to 2016-06-16 12:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:14:47 UTC to 2016-06-16 13:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:34:45 UTC to 2016-06-16 13:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:54:44 UTC to 2016-06-16 13:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:14:44 UTC to 2016-06-16 14:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:34:44 UTC to 2016-06-16 14:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:54:44 UTC to 2016-06-16 14:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:14:44 UTC to 2016-06-16 15:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:34:45 UTC to 2016-06-16 15:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:54:45 UTC to 2016-06-16 15:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:14:44 UTC to 2016-06-16 16:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:34:44 UTC to 2016-06-16 16:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:54:44 UTC to 2016-06-16 16:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:14:44 UTC to 2016-06-16 17:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:34:44 UTC to 2016-06-16 17:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:54:44 UTC to 2016-06-16 17:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:14:44 UTC to 2016-06-16 18:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:34:44 UTC to 2016-06-16 18:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:54:44 UTC to 2016-06-16 18:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:14:44 UTC to 2016-06-16 19:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:34:44 UTC to 2016-06-16 19:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:54:44 UTC to 2016-06-16 19:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:14:44 UTC to 2016-06-16 20:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:34:44 UTC to 2016-06-16 20:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:54:44 UTC to 2016-06-16 20:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:14:44 UTC to 2016-06-16 21:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:34:44 UTC to 2016-06-16 21:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:54:44 UTC to 2016-06-16 21:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:14:44 UTC to 2016-06-16 22:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:34:44 UTC to 2016-06-16 22:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:54:44 UTC to 2016-06-16 22:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:14:44 UTC to 2016-06-16 23:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:34:44 UTC to 2016-06-16 23:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:54:44 UTC to 2016-06-16 23:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:14:45 UTC to 2016-06-17 00:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:34:44 UTC to 2016-06-17 00:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:54:44 UTC to 2016-06-17 00:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:14:44 UTC to 2016-06-17 01:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:34:44 UTC to 2016-06-17 01:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:54:44 UTC to 2016-06-17 01:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:14:44 UTC to 2016-06-17 02:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:34:44 UTC to 2016-06-17 02:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:54:44 UTC to 2016-06-17 02:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:14:44 UTC to 2016-06-17 03:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:34:44 UTC to 2016-06-17 03:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:54:44 UTC to 2016-06-17 03:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:14:44 UTC to 2016-06-17 04:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:34:44 UTC to 2016-06-17 04:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:54:44 UTC to 2016-06-17 04:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:14:44 UTC to 2016-06-17 05:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:34:44 UTC to 2016-06-17 05:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:54:44 UTC to 2016-06-17 05:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:14:44 UTC to 2016-06-17 06:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:34:44 UTC to 2016-06-17 06:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:54:44 UTC to 2016-06-17 06:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:14:44 UTC to 2016-06-17 07:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:34:44 UTC to 2016-06-17 07:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:54:44 UTC to 2016-06-17 07:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:14:44 UTC to 2016-06-17 08:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:34:44 UTC to 2016-06-17 08:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:54:44 UTC to 2016-06-17 08:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:14:44 UTC to 2016-06-17 09:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:34:44 UTC to 2016-06-17 09:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:54:44 UTC to 2016-06-17 09:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:14:44 UTC to 2016-06-17 10:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:34:44 UTC to 2016-06-17 10:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:54:44 UTC to 2016-06-17 10:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:14:44 UTC to 2016-06-17 11:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:34:44 UTC to 2016-06-17 11:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:54:44 UTC to 2016-06-17 11:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:14:43 UTC to 2016-06-17 12:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:34:44 UTC to 2016-06-17 12:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:54:44 UTC to 2016-06-17 12:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:14:44 UTC to 2016-06-17 13:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:34:43 UTC to 2016-06-17 13:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:54:43 UTC to 2016-06-17 13:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:14:43 UTC to 2016-06-17 14:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:34:43 UTC to 2016-06-17 14:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:54:43 UTC to 2016-06-17 14:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:14:43 UTC to 2016-06-17 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:34:44 UTC to 2016-06-17 15:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:54:43 UTC to 2016-06-17 15:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:14:43 UTC to 2016-06-17 16:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:34:43 UTC to 2016-06-17 16:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:54:43 UTC to 2016-06-17 16:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:14:43 UTC to 2016-06-17 17:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:34:43 UTC to 2016-06-17 17:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:54:43 UTC to 2016-06-17 17:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:14:43 UTC to 2016-06-17 18:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:34:43 UTC to 2016-06-17 18:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:54:43 UTC to 2016-06-17 18:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:14:43 UTC to 2016-06-17 19:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:34:43 UTC to 2016-06-17 19:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:54:43 UTC to 2016-06-17 19:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:14:43 UTC to 2016-06-17 20:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:34:43 UTC to 2016-06-17 20:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:54:43 UTC to 2016-06-17 20:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:14:43 UTC to 2016-06-17 21:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:34:43 UTC to 2016-06-17 21:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:54:43 UTC to 2016-06-17 21:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:14:43 UTC to 2016-06-17 22:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:34:43 UTC to 2016-06-17 22:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:54:43 UTC to 2016-06-17 22:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:14:43 UTC to 2016-06-17 23:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:34:43 UTC to 2016-06-17 23:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:54:43 UTC to 2016-06-17 23:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:14:43 UTC to 2016-06-18 00:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:34:43 UTC to 2016-06-18 00:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:54:43 UTC to 2016-06-18 00:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:14:43 UTC to 2016-06-18 01:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:34:43 UTC to 2016-06-18 01:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:54:43 UTC to 2016-06-18 01:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:14:43 UTC to 2016-06-18 02:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:34:43 UTC to 2016-06-18 02:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:54:43 UTC to 2016-06-18 02:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:14:43 UTC to 2016-06-18 03:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:34:43 UTC to 2016-06-18 03:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:54:43 UTC to 2016-06-18 03:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:14:43 UTC to 2016-06-18 04:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:34:43 UTC to 2016-06-18 04:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:54:43 UTC to 2016-06-18 04:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:14:43 UTC to 2016-06-18 05:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:34:43 UTC to 2016-06-18 05:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:54:43 UTC to 2016-06-18 05:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:14:43 UTC to 2016-06-18 06:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:34:43 UTC to 2016-06-18 06:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:54:43 UTC to 2016-06-18 06:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:14:43 UTC to 2016-06-18 07:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:34:43 UTC to 2016-06-18 07:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:54:43 UTC to 2016-06-18 07:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:14:43 UTC to 2016-06-18 08:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:34:43 UTC to 2016-06-18 08:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:54:43 UTC to 2016-06-18 08:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:14:43 UTC to 2016-06-18 09:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:34:43 UTC to 2016-06-18 09:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:54:43 UTC to 2016-06-18 09:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:14:43 UTC to 2016-06-18 10:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:34:43 UTC to 2016-06-18 10:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:54:43 UTC to 2016-06-18 10:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:14:43 UTC to 2016-06-18 11:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:34:43 UTC to 2016-06-18 11:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:54:43 UTC to 2016-06-18 11:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:14:43 UTC to 2016-06-18 12:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:34:43 UTC to 2016-06-18 12:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:54:43 UTC to 2016-06-18 12:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:14:43 UTC to 2016-06-18 13:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:34:43 UTC to 2016-06-18 13:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:54:43 UTC to 2016-06-18 13:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:14:43 UTC to 2016-06-18 14:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:34:43 UTC to 2016-06-18 14:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:54:43 UTC to 2016-06-18 14:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:14:43 UTC to 2016-06-18 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:34:43 UTC to 2016-06-18 15:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:54:43 UTC to 2016-06-18 15:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:14:44 UTC to 2016-06-18 16:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:34:42 UTC to 2016-06-18 16:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:54:42 UTC to 2016-06-18 16:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:14:42 UTC to 2016-06-18 17:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:34:42 UTC to 2016-06-18 17:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:54:42 UTC to 2016-06-18 17:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:14:42 UTC to 2016-06-18 18:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:34:42 UTC to 2016-06-18 18:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:54:42 UTC to 2016-06-18 18:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:14:42 UTC to 2016-06-18 19:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:34:42 UTC to 2016-06-18 19:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:54:42 UTC to 2016-06-18 19:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:14:42 UTC to 2016-06-18 20:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:34:42 UTC to 2016-06-18 20:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:54:42 UTC to 2016-06-18 20:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:14:42 UTC to 2016-06-18 21:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:34:42 UTC to 2016-06-18 21:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:54:42 UTC to 2016-06-18 21:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:14:42 UTC to 2016-06-18 22:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:34:42 UTC to 2016-06-18 22:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:54:42 UTC to 2016-06-18 22:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:14:42 UTC to 2016-06-18 23:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:34:42 UTC to 2016-06-18 23:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:54:42 UTC to 2016-06-18 23:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:14:42 UTC to 2016-06-19 00:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:34:42 UTC to 2016-06-19 00:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:54:42 UTC to 2016-06-19 00:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:14:42 UTC to 2016-06-19 01:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:34:42 UTC to 2016-06-19 01:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:54:42 UTC to 2016-06-19 01:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:14:42 UTC to 2016-06-19 02:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:34:42 UTC to 2016-06-19 02:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:54:42 UTC to 2016-06-19 02:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:14:42 UTC to 2016-06-19 03:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:34:42 UTC to 2016-06-19 03:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:54:42 UTC to 2016-06-19 03:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:14:42 UTC to 2016-06-19 04:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:34:42 UTC to 2016-06-19 04:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:54:42 UTC to 2016-06-19 04:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:14:42 UTC to 2016-06-19 05:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:34:42 UTC to 2016-06-19 05:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:54:42 UTC to 2016-06-19 05:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:14:42 UTC to 2016-06-19 06:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:34:42 UTC to 2016-06-19 06:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:54:42 UTC to 2016-06-19 06:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:14:42 UTC to 2016-06-19 07:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:34:42 UTC to 2016-06-19 07:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:54:42 UTC to 2016-06-19 07:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:14:42 UTC to 2016-06-19 08:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:34:42 UTC to 2016-06-19 08:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:54:42 UTC to 2016-06-19 08:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:14:42 UTC to 2016-06-19 09:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:34:42 UTC to 2016-06-19 09:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:54:42 UTC to 2016-06-19 09:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:14:42 UTC to 2016-06-19 10:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:34:42 UTC to 2016-06-19 10:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:54:42 UTC to 2016-06-19 10:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:14:42 UTC to 2016-06-19 11:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:34:42 UTC to 2016-06-19 11:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:54:42 UTC to 2016-06-19 11:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:14:42 UTC to 2016-06-19 12:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:34:42 UTC to 2016-06-19 12:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:54:42 UTC to 2016-06-19 12:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:14:42 UTC to 2016-06-19 13:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:34:42 UTC to 2016-06-19 13:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:54:42 UTC to 2016-06-19 13:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:14:42 UTC to 2016-06-19 14:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:34:42 UTC to 2016-06-19 14:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:54:42 UTC to 2016-06-19 14:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:14:43 UTC to 2016-06-19 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:34:42 UTC to 2016-06-19 15:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:54:42 UTC to 2016-06-19 15:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:14:42 UTC to 2016-06-19 16:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:34:42 UTC to 2016-06-19 16:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:54:42 UTC to 2016-06-19 16:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:14:42 UTC to 2016-06-19 17:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:34:42 UTC to 2016-06-19 17:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:54:42 UTC to 2016-06-19 17:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:14:42 UTC to 2016-06-19 18:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:34:42 UTC to 2016-06-19 18:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:54:42 UTC to 2016-06-19 18:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:14:42 UTC to 2016-06-19 19:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:34:41 UTC to 2016-06-19 19:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:54:41 UTC to 2016-06-19 19:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:14:41 UTC to 2016-06-19 20:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:34:41 UTC to 2016-06-19 20:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:54:41 UTC to 2016-06-19 20:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:14:41 UTC to 2016-06-19 21:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:34:41 UTC to 2016-06-19 21:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:54:41 UTC to 2016-06-19 21:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:14:41 UTC to 2016-06-19 22:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:34:41 UTC to 2016-06-19 22:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:54:41 UTC to 2016-06-19 22:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:14:41 UTC to 2016-06-19 23:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:34:41 UTC to 2016-06-19 23:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:54:41 UTC to 2016-06-19 23:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:14:41 UTC to 2016-06-20 00:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:34:41 UTC to 2016-06-20 00:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:54:41 UTC to 2016-06-20 00:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:14:41 UTC to 2016-06-20 01:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:34:41 UTC to 2016-06-20 01:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:54:41 UTC to 2016-06-20 01:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:14:41 UTC to 2016-06-20 02:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:34:41 UTC to 2016-06-20 02:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:54:41 UTC to 2016-06-20 02:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:14:41 UTC to 2016-06-20 03:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:34:41 UTC to 2016-06-20 03:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:54:41 UTC to 2016-06-20 03:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:14:41 UTC to 2016-06-20 04:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:34:41 UTC to 2016-06-20 04:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:54:41 UTC to 2016-06-20 04:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:14:41 UTC to 2016-06-20 05:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:34:41 UTC to 2016-06-20 05:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:54:41 UTC to 2016-06-20 05:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:14:41 UTC to 2016-06-20 06:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:34:41 UTC to 2016-06-20 06:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:54:41 UTC to 2016-06-20 06:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:14:41 UTC to 2016-06-20 07:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:34:41 UTC to 2016-06-20 07:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:54:41 UTC to 2016-06-20 07:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:14:41 UTC to 2016-06-20 08:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:34:41 UTC to 2016-06-20 08:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:54:41 UTC to 2016-06-20 08:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:14:41 UTC to 2016-06-20 09:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:34:41 UTC to 2016-06-20 09:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:54:41 UTC to 2016-06-20 09:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:14:41 UTC to 2016-06-20 10:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:34:41 UTC to 2016-06-20 10:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:54:41 UTC to 2016-06-20 10:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:14:41 UTC to 2016-06-20 11:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:34:41 UTC to 2016-06-20 11:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:54:41 UTC to 2016-06-20 11:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:14:41 UTC to 2016-06-20 12:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:34:41 UTC to 2016-06-20 12:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:54:41 UTC to 2016-06-20 12:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:14:41 UTC to 2016-06-20 13:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:34:41 UTC to 2016-06-20 13:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:54:41 UTC to 2016-06-20 13:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:14:41 UTC to 2016-06-20 14:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:34:41 UTC to 2016-06-20 14:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:54:41 UTC to 2016-06-20 14:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:14:41 UTC to 2016-06-20 15:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:34:41 UTC to 2016-06-20 15:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:54:41 UTC to 2016-06-20 15:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:14:41 UTC to 2016-06-20 16:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:34:41 UTC to 2016-06-20 16:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:54:41 UTC to 2016-06-20 16:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:14:41 UTC to 2016-06-20 17:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:34:41 UTC to 2016-06-20 17:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:54:41 UTC to 2016-06-20 17:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:14:41 UTC to 2016-06-20 18:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:34:41 UTC to 2016-06-20 18:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:54:41 UTC to 2016-06-20 18:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:14:41 UTC to 2016-06-20 19:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:34:41 UTC to 2016-06-20 19:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:54:41 UTC to 2016-06-20 19:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:14:41 UTC to 2016-06-20 20:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:34:41 UTC to 2016-06-20 20:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:54:41 UTC to 2016-06-20 20:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:14:41 UTC to 2016-06-20 21:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:34:41 UTC to 2016-06-20 21:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:54:41 UTC to 2016-06-20 21:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:14:40 UTC to 2016-06-20 22:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:34:40 UTC to 2016-06-20 22:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:54:41 UTC to 2016-06-20 22:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:14:41 UTC to 2016-06-20 23:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:34:41 UTC to 2016-06-20 23:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:54:41 UTC to 2016-06-20 23:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:14:41 UTC to 2016-06-21 00:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:34:40 UTC to 2016-06-21 00:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:54:40 UTC to 2016-06-21 00:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:14:40 UTC to 2016-06-21 01:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:34:40 UTC to 2016-06-21 01:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:54:40 UTC to 2016-06-21 01:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:14:40 UTC to 2016-06-21 02:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:34:40 UTC to 2016-06-21 02:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:54:40 UTC to 2016-06-21 02:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:14:40 UTC to 2016-06-21 03:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:34:40 UTC to 2016-06-21 03:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:54:40 UTC to 2016-06-21 03:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:14:40 UTC to 2016-06-21 04:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:34:40 UTC to 2016-06-21 04:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:54:40 UTC to 2016-06-21 04:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:14:40 UTC to 2016-06-21 05:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:34:40 UTC to 2016-06-21 05:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:54:40 UTC to 2016-06-21 05:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:14:40 UTC to 2016-06-21 06:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:34:40 UTC to 2016-06-21 06:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:54:40 UTC to 2016-06-21 06:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:14:40 UTC to 2016-06-21 07:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:34:40 UTC to 2016-06-21 07:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:54:40 UTC to 2016-06-21 07:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:14:40 UTC to 2016-06-21 08:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:34:40 UTC to 2016-06-21 08:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:54:40 UTC to 2016-06-21 08:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:14:40 UTC to 2016-06-21 09:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:34:40 UTC to 2016-06-21 09:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:54:40 UTC to 2016-06-21 09:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:14:40 UTC to 2016-06-21 10:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:34:40 UTC to 2016-06-21 10:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:54:40 UTC to 2016-06-21 10:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:14:40 UTC to 2016-06-21 11:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:34:40 UTC to 2016-06-21 11:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:54:40 UTC to 2016-06-21 11:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:14:40 UTC to 2016-06-21 12:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:34:40 UTC to 2016-06-21 12:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:54:40 UTC to 2016-06-21 12:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:14:40 UTC to 2016-06-21 13:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:34:40 UTC to 2016-06-21 13:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:54:40 UTC to 2016-06-21 13:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:14:40 UTC to 2016-06-21 14:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:34:40 UTC to 2016-06-21 14:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:54:40 UTC to 2016-06-21 14:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:14:40 UTC to 2016-06-21 15:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:34:40 UTC to 2016-06-21 15:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:54:40 UTC to 2016-06-21 15:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:14:40 UTC to 2016-06-21 16:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:34:40 UTC to 2016-06-21 16:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:54:40 UTC to 2016-06-21 16:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:14:40 UTC to 2016-06-21 17:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:34:40 UTC to 2016-06-21 17:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:54:40 UTC to 2016-06-21 17:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:14:40 UTC to 2016-06-21 18:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:34:40 UTC to 2016-06-21 18:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:54:40 UTC to 2016-06-21 18:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:14:40 UTC to 2016-06-21 19:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:34:40 UTC to 2016-06-21 19:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:54:40 UTC to 2016-06-21 19:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:14:40 UTC to 2016-06-21 20:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:34:40 UTC to 2016-06-21 20:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:54:40 UTC to 2016-06-21 20:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:14:40 UTC to 2016-06-21 21:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:34:40 UTC to 2016-06-21 21:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:54:40 UTC to 2016-06-21 21:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:14:40 UTC to 2016-06-21 22:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:34:40 UTC to 2016-06-21 22:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:54:40 UTC to 2016-06-21 22:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:14:40 UTC to 2016-06-21 23:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:34:40 UTC to 2016-06-21 23:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:54:40 UTC to 2016-06-21 23:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:14:40 UTC to 2016-06-22 00:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:34:40 UTC to 2016-06-22 00:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:54:40 UTC to 2016-06-22 00:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:14:39 UTC to 2016-06-22 01:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:34:39 UTC to 2016-06-22 01:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:54:39 UTC to 2016-06-22 01:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:14:39 UTC to 2016-06-22 02:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:34:40 UTC to 2016-06-22 02:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:54:40 UTC to 2016-06-22 02:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:14:39 UTC to 2016-06-22 03:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:34:40 UTC to 2016-06-22 03:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:54:40 UTC to 2016-06-22 03:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:14:39 UTC to 2016-06-22 04:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:34:40 UTC to 2016-06-22 04:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:54:40 UTC to 2016-06-22 04:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:14:39 UTC to 2016-06-22 05:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:34:39 UTC to 2016-06-22 05:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:54:39 UTC to 2016-06-22 05:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:14:39 UTC to 2016-06-22 06:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:34:39 UTC to 2016-06-22 06:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:54:39 UTC to 2016-06-22 06:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:14:39 UTC to 2016-06-22 07:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:34:39 UTC to 2016-06-22 07:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:54:39 UTC to 2016-06-22 07:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:14:39 UTC to 2016-06-22 08:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:34:39 UTC to 2016-06-22 08:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:54:39 UTC to 2016-06-22 08:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 09:14:39 UTC to 2016-06-22 09:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 09:34:39 UTC to 2016-06-22 09:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:20:03 UTC to 2016-06-23 20:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:30:03 UTC to 2016-06-23 20:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:50:03 UTC to 2016-06-23 20:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:10:03 UTC to 2016-06-23 21:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:30:03 UTC to 2016-06-23 21:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:50:03 UTC to 2016-06-23 21:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:10:03 UTC to 2016-06-23 22:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:30:03 UTC to 2016-06-23 22:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:50:03 UTC to 2016-06-23 22:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:10:03 UTC to 2016-06-23 23:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:30:03 UTC to 2016-06-23 23:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:50:03 UTC to 2016-06-23 23:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:10:03 UTC to 2016-06-24 00:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:30:03 UTC to 2016-06-24 00:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:50:03 UTC to 2016-06-24 00:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:10:03 UTC to 2016-06-24 01:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:30:03 UTC to 2016-06-24 01:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:50:03 UTC to 2016-06-24 01:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:10:03 UTC to 2016-06-24 02:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:30:03 UTC to 2016-06-24 02:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:50:03 UTC to 2016-06-24 02:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:10:03 UTC to 2016-06-24 03:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:30:03 UTC to 2016-06-24 03:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:50:03 UTC to 2016-06-24 03:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:10:03 UTC to 2016-06-24 04:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:30:03 UTC to 2016-06-24 04:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:50:03 UTC to 2016-06-24 04:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:10:03 UTC to 2016-06-24 05:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:30:03 UTC to 2016-06-24 05:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:50:03 UTC to 2016-06-24 05:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:10:03 UTC to 2016-06-24 06:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:30:03 UTC to 2016-06-24 06:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:50:03 UTC to 2016-06-24 06:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:10:03 UTC to 2016-06-24 07:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:30:03 UTC to 2016-06-24 07:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:50:03 UTC to 2016-06-24 07:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:10:03 UTC to 2016-06-24 08:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:30:03 UTC to 2016-06-24 08:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:50:03 UTC to 2016-06-24 08:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:10:03 UTC to 2016-06-24 09:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:30:03 UTC to 2016-06-24 09:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:50:03 UTC to 2016-06-24 09:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:10:03 UTC to 2016-06-24 10:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:30:03 UTC to 2016-06-24 10:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:50:02 UTC to 2016-06-24 10:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:10:03 UTC to 2016-06-24 11:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:30:03 UTC to 2016-06-24 11:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:50:02 UTC to 2016-06-24 11:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:10:02 UTC to 2016-06-24 12:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:30:02 UTC to 2016-06-24 12:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:50:02 UTC to 2016-06-24 12:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:10:02 UTC to 2016-06-24 13:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:30:02 UTC to 2016-06-24 13:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:50:02 UTC to 2016-06-24 13:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:10:02 UTC to 2016-06-24 14:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:30:02 UTC to 2016-06-24 14:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:50:02 UTC to 2016-06-24 14:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:10:02 UTC to 2016-06-24 15:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:30:02 UTC to 2016-06-24 15:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:50:02 UTC to 2016-06-24 15:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:10:02 UTC to 2016-06-24 16:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:30:02 UTC to 2016-06-24 16:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:50:02 UTC to 2016-06-24 16:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:10:02 UTC to 2016-06-24 17:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:30:02 UTC to 2016-06-24 17:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:50:02 UTC to 2016-06-24 17:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:10:02 UTC to 2016-06-24 18:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:30:02 UTC to 2016-06-24 18:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:50:02 UTC to 2016-06-24 18:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:10:02 UTC to 2016-06-24 19:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:30:02 UTC to 2016-06-24 19:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:50:02 UTC to 2016-06-24 19:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:10:02 UTC to 2016-06-24 20:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:30:02 UTC to 2016-06-24 20:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:50:02 UTC to 2016-06-24 20:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:10:02 UTC to 2016-06-24 21:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:30:02 UTC to 2016-06-24 21:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:50:02 UTC to 2016-06-24 21:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:10:02 UTC to 2016-06-24 22:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:30:02 UTC to 2016-06-24 22:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:50:02 UTC to 2016-06-24 22:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:10:02 UTC to 2016-06-24 23:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:30:02 UTC to 2016-06-24 23:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:50:02 UTC to 2016-06-24 23:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:10:02 UTC to 2016-06-25 00:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:30:02 UTC to 2016-06-25 00:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:50:02 UTC to 2016-06-25 00:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:10:02 UTC to 2016-06-25 01:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:30:02 UTC to 2016-06-25 01:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:50:02 UTC to 2016-06-25 01:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:10:02 UTC to 2016-06-25 02:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:30:02 UTC to 2016-06-25 02:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:50:02 UTC to 2016-06-25 02:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:10:02 UTC to 2016-06-25 03:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:30:02 UTC to 2016-06-25 03:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:50:02 UTC to 2016-06-25 03:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:10:02 UTC to 2016-06-25 04:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:30:02 UTC to 2016-06-25 04:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:50:02 UTC to 2016-06-25 04:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:10:02 UTC to 2016-06-25 05:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:30:02 UTC to 2016-06-25 05:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:50:02 UTC to 2016-06-25 05:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:10:02 UTC to 2016-06-25 06:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:30:02 UTC to 2016-06-25 06:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:50:02 UTC to 2016-06-25 06:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:10:02 UTC to 2016-06-25 07:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:30:02 UTC to 2016-06-25 07:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:50:02 UTC to 2016-06-25 07:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:10:02 UTC to 2016-06-25 08:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:30:02 UTC to 2016-06-25 08:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:50:02 UTC to 2016-06-25 08:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 09:10:02 UTC to 2016-06-25 09:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 09:30:02 UTC to 2016-06-25 09:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 14:24:30 UTC to 2016-06-26 14:24:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 15:04:30 UTC to 2016-06-26 15:04:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 15:44:30 UTC to 2016-06-26 15:44:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:04:29 UTC to 2016-06-26 16:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:24:30 UTC to 2016-06-26 16:24:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:44:29 UTC to 2016-06-26 16:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:04:29 UTC to 2016-06-26 17:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:24:29 UTC to 2016-06-26 17:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:44:29 UTC to 2016-06-26 17:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:04:29 UTC to 2016-06-26 18:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:24:29 UTC to 2016-06-26 18:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:44:29 UTC to 2016-06-26 18:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:04:29 UTC to 2016-06-26 19:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:24:29 UTC to 2016-06-26 19:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:44:29 UTC to 2016-06-26 19:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:04:29 UTC to 2016-06-26 20:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:24:29 UTC to 2016-06-26 20:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:44:29 UTC to 2016-06-26 20:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:04:29 UTC to 2016-06-26 21:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:24:29 UTC to 2016-06-26 21:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:44:29 UTC to 2016-06-26 21:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:04:29 UTC to 2016-06-26 22:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:24:29 UTC to 2016-06-26 22:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:44:29 UTC to 2016-06-26 22:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 23:04:29 UTC to 2016-06-26 23:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 23:24:29 UTC to 2016-06-26 23:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:04:29 UTC to 2016-06-27 00:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:24:29 UTC to 2016-06-27 00:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:44:29 UTC to 2016-06-27 00:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:04:29 UTC to 2016-06-27 01:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:24:29 UTC to 2016-06-27 01:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:44:29 UTC to 2016-06-27 01:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:04:29 UTC to 2016-06-27 02:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:24:29 UTC to 2016-06-27 02:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:44:29 UTC to 2016-06-27 02:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:04:29 UTC to 2016-06-27 03:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:24:29 UTC to 2016-06-27 03:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:44:29 UTC to 2016-06-27 03:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:04:29 UTC to 2016-06-27 04:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:24:29 UTC to 2016-06-27 04:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:44:29 UTC to 2016-06-27 04:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:04:29 UTC to 2016-06-27 05:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:24:29 UTC to 2016-06-27 05:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:44:29 UTC to 2016-06-27 05:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:04:29 UTC to 2016-06-27 06:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:24:29 UTC to 2016-06-27 06:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:44:29 UTC to 2016-06-27 06:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:04:29 UTC to 2016-06-27 07:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:24:29 UTC to 2016-06-27 07:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:44:29 UTC to 2016-06-27 07:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:04:29 UTC to 2016-06-27 08:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:24:29 UTC to 2016-06-27 08:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:44:29 UTC to 2016-06-27 08:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:04:29 UTC to 2016-06-27 09:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:24:29 UTC to 2016-06-27 09:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:44:29 UTC to 2016-06-27 09:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:04:29 UTC to 2016-06-27 10:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:24:29 UTC to 2016-06-27 10:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:44:29 UTC to 2016-06-27 10:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:04:29 UTC to 2016-06-27 11:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:24:29 UTC to 2016-06-27 11:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:44:29 UTC to 2016-06-27 11:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:04:29 UTC to 2016-06-27 12:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:24:29 UTC to 2016-06-27 12:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:44:29 UTC to 2016-06-27 12:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:04:29 UTC to 2016-06-27 13:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:24:29 UTC to 2016-06-27 13:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:44:29 UTC to 2016-06-27 13:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:04:29 UTC to 2016-06-27 14:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:24:29 UTC to 2016-06-27 14:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:44:29 UTC to 2016-06-27 14:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:04:29 UTC to 2016-06-27 15:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:24:29 UTC to 2016-06-27 15:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:44:29 UTC to 2016-06-27 15:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:04:29 UTC to 2016-06-27 16:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:24:29 UTC to 2016-06-27 16:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:44:29 UTC to 2016-06-27 16:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:04:29 UTC to 2016-06-27 17:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:24:29 UTC to 2016-06-27 17:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:44:29 UTC to 2016-06-27 17:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:04:29 UTC to 2016-06-27 18:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:24:29 UTC to 2016-06-27 18:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:44:29 UTC to 2016-06-27 18:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:04:29 UTC to 2016-06-27 19:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:24:29 UTC to 2016-06-27 19:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:44:29 UTC to 2016-06-27 19:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:04:28 UTC to 2016-06-27 20:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:24:29 UTC to 2016-06-27 20:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:44:28 UTC to 2016-06-27 20:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:04:29 UTC to 2016-06-27 21:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:24:29 UTC to 2016-06-27 21:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:44:29 UTC to 2016-06-27 21:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:04:29 UTC to 2016-06-27 22:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:24:28 UTC to 2016-06-27 22:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:44:28 UTC to 2016-06-27 22:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:04:28 UTC to 2016-06-27 23:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:24:28 UTC to 2016-06-27 23:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:44:28 UTC to 2016-06-27 23:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:04:28 UTC to 2016-06-28 00:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:24:28 UTC to 2016-06-28 00:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:44:28 UTC to 2016-06-28 00:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:04:28 UTC to 2016-06-28 01:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:24:28 UTC to 2016-06-28 01:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:44:28 UTC to 2016-06-28 01:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:04:28 UTC to 2016-06-28 02:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:24:28 UTC to 2016-06-28 02:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:44:28 UTC to 2016-06-28 02:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:04:28 UTC to 2016-06-28 03:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:24:28 UTC to 2016-06-28 03:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:44:28 UTC to 2016-06-28 03:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:04:28 UTC to 2016-06-28 04:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:24:28 UTC to 2016-06-28 04:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:44:28 UTC to 2016-06-28 04:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:04:28 UTC to 2016-06-28 05:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:24:28 UTC to 2016-06-28 05:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:44:28 UTC to 2016-06-28 05:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:04:28 UTC to 2016-06-28 06:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:24:28 UTC to 2016-06-28 06:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:44:28 UTC to 2016-06-28 06:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:04:28 UTC to 2016-06-28 07:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:24:28 UTC to 2016-06-28 07:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:44:28 UTC to 2016-06-28 07:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:04:28 UTC to 2016-06-28 08:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:24:28 UTC to 2016-06-28 08:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:44:28 UTC to 2016-06-28 08:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:04:28 UTC to 2016-06-28 09:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:24:28 UTC to 2016-06-28 09:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:44:28 UTC to 2016-06-28 09:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:04:28 UTC to 2016-06-28 10:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:24:28 UTC to 2016-06-28 10:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:44:28 UTC to 2016-06-28 10:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:04:28 UTC to 2016-06-28 11:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:24:28 UTC to 2016-06-28 11:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:44:28 UTC to 2016-06-28 11:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 12:04:28 UTC to 2016-06-28 12:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 12:24:28 UTC to 2016-06-28 12:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:21:41 UTC to 2016-06-30 20:22:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:31:41 UTC to 2016-06-30 20:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:51:41 UTC to 2016-06-30 20:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:11:41 UTC to 2016-06-30 21:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:31:41 UTC to 2016-06-30 21:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:51:41 UTC to 2016-06-30 21:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:11:41 UTC to 2016-06-30 22:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:31:41 UTC to 2016-06-30 22:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:51:41 UTC to 2016-06-30 22:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:11:41 UTC to 2016-06-30 23:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:31:41 UTC to 2016-06-30 23:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:51:41 UTC to 2016-06-30 23:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:11:41 UTC to 2016-07-01 00:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:31:41 UTC to 2016-07-01 00:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:51:41 UTC to 2016-07-01 00:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:11:41 UTC to 2016-07-01 01:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:31:40 UTC to 2016-07-01 01:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:51:41 UTC to 2016-07-01 01:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:11:40 UTC to 2016-07-01 02:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:31:40 UTC to 2016-07-01 02:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:51:40 UTC to 2016-07-01 02:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:11:41 UTC to 2016-07-01 03:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:31:40 UTC to 2016-07-01 03:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:51:40 UTC to 2016-07-01 03:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:11:40 UTC to 2016-07-01 04:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:31:40 UTC to 2016-07-01 04:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:51:40 UTC to 2016-07-01 04:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:11:40 UTC to 2016-07-01 05:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:31:40 UTC to 2016-07-01 05:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:51:40 UTC to 2016-07-01 05:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:11:40 UTC to 2016-07-01 06:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:31:40 UTC to 2016-07-01 06:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:51:40 UTC to 2016-07-01 06:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:11:40 UTC to 2016-07-01 07:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:31:40 UTC to 2016-07-01 07:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:51:40 UTC to 2016-07-01 07:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 08:14:58 UTC to 2016-06-01 08:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 08:35:02 UTC to 2016-06-01 08:35:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 08:54:58 UTC to 2016-06-01 08:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:14:58 UTC to 2016-06-01 09:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:34:58 UTC to 2016-06-01 09:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 09:54:58 UTC to 2016-06-01 09:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:14:58 UTC to 2016-06-01 10:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:34:58 UTC to 2016-06-01 10:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 10:54:58 UTC to 2016-06-01 10:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:14:58 UTC to 2016-06-01 11:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:34:58 UTC to 2016-06-01 11:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 11:54:58 UTC to 2016-06-01 11:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:14:58 UTC to 2016-06-01 12:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:34:58 UTC to 2016-06-01 12:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 12:54:58 UTC to 2016-06-01 12:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:14:57 UTC to 2016-06-01 13:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:34:58 UTC to 2016-06-01 13:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 13:54:58 UTC to 2016-06-01 13:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:14:57 UTC to 2016-06-01 14:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:34:57 UTC to 2016-06-01 14:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 14:54:57 UTC to 2016-06-01 14:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:14:59 UTC to 2016-06-01 15:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:34:57 UTC to 2016-06-01 15:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 15:54:57 UTC to 2016-06-01 15:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:14:59 UTC to 2016-06-01 16:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:34:58 UTC to 2016-06-01 16:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 16:54:57 UTC to 2016-06-01 16:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:14:57 UTC to 2016-06-01 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:34:57 UTC to 2016-06-01 17:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 17:54:57 UTC to 2016-06-01 17:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:14:58 UTC to 2016-06-01 18:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:34:57 UTC to 2016-06-01 18:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 18:54:57 UTC to 2016-06-01 18:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:14:57 UTC to 2016-06-01 19:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:34:57 UTC to 2016-06-01 19:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 19:54:57 UTC to 2016-06-01 19:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:14:58 UTC to 2016-06-01 20:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:34:57 UTC to 2016-06-01 20:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 20:54:57 UTC to 2016-06-01 20:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:14:57 UTC to 2016-06-01 21:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:34:58 UTC to 2016-06-01 21:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 21:54:58 UTC to 2016-06-01 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:14:58 UTC to 2016-06-01 22:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:34:57 UTC to 2016-06-01 22:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 22:55:00 UTC to 2016-06-01 22:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:14:57 UTC to 2016-06-01 23:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:34:57 UTC to 2016-06-01 23:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-01 23:54:57 UTC to 2016-06-01 23:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:14:57 UTC to 2016-06-02 00:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:34:57 UTC to 2016-06-02 00:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 00:54:57 UTC to 2016-06-02 00:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:14:57 UTC to 2016-06-02 01:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:34:57 UTC to 2016-06-02 01:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 01:55:00 UTC to 2016-06-02 01:55:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:14:57 UTC to 2016-06-02 02:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:34:57 UTC to 2016-06-02 02:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 02:54:57 UTC to 2016-06-02 02:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:14:57 UTC to 2016-06-02 03:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:34:57 UTC to 2016-06-02 03:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 03:54:57 UTC to 2016-06-02 03:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:14:57 UTC to 2016-06-02 04:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:34:57 UTC to 2016-06-02 04:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 04:54:57 UTC to 2016-06-02 04:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:14:57 UTC to 2016-06-02 05:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:34:57 UTC to 2016-06-02 05:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 05:54:57 UTC to 2016-06-02 05:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:14:57 UTC to 2016-06-02 06:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:34:57 UTC to 2016-06-02 06:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 06:54:57 UTC to 2016-06-02 06:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:14:57 UTC to 2016-06-02 07:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:34:57 UTC to 2016-06-02 07:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 07:54:57 UTC to 2016-06-02 07:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:14:57 UTC to 2016-06-02 08:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:34:57 UTC to 2016-06-02 08:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 08:54:57 UTC to 2016-06-02 08:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:14:57 UTC to 2016-06-02 09:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:34:57 UTC to 2016-06-02 09:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 09:54:57 UTC to 2016-06-02 09:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:14:57 UTC to 2016-06-02 10:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:34:57 UTC to 2016-06-02 10:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 10:54:57 UTC to 2016-06-02 10:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:14:57 UTC to 2016-06-02 11:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:34:57 UTC to 2016-06-02 11:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 11:54:57 UTC to 2016-06-02 11:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:14:57 UTC to 2016-06-02 12:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:34:57 UTC to 2016-06-02 12:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 12:54:57 UTC to 2016-06-02 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:15:04 UTC to 2016-06-02 13:15:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:34:57 UTC to 2016-06-02 13:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 13:54:57 UTC to 2016-06-02 13:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:14:57 UTC to 2016-06-02 14:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:34:57 UTC to 2016-06-02 14:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 14:54:57 UTC to 2016-06-02 14:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:14:57 UTC to 2016-06-02 15:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:34:57 UTC to 2016-06-02 15:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 15:54:56 UTC to 2016-06-02 15:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:14:56 UTC to 2016-06-02 16:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:34:56 UTC to 2016-06-02 16:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 16:54:56 UTC to 2016-06-02 16:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:14:57 UTC to 2016-06-02 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:34:57 UTC to 2016-06-02 17:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 17:54:57 UTC to 2016-06-02 17:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:14:56 UTC to 2016-06-02 18:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:34:57 UTC to 2016-06-02 18:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 18:54:56 UTC to 2016-06-02 18:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:14:57 UTC to 2016-06-02 19:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:34:57 UTC to 2016-06-02 19:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 19:54:56 UTC to 2016-06-02 19:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 20:34:56 UTC to 2016-06-02 20:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 20:54:56 UTC to 2016-06-02 20:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:14:58 UTC to 2016-06-02 21:15:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:34:56 UTC to 2016-06-02 21:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 21:54:56 UTC to 2016-06-02 21:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:14:59 UTC to 2016-06-02 22:15:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:34:57 UTC to 2016-06-02 22:35:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 22:54:56 UTC to 2016-06-02 22:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:14:56 UTC to 2016-06-02 23:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:34:56 UTC to 2016-06-02 23:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-02 23:54:56 UTC to 2016-06-02 23:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:14:56 UTC to 2016-06-03 00:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:34:56 UTC to 2016-06-03 00:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 00:54:56 UTC to 2016-06-03 00:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:14:57 UTC to 2016-06-03 01:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:34:56 UTC to 2016-06-03 01:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 01:54:56 UTC to 2016-06-03 01:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:14:56 UTC to 2016-06-03 02:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:34:56 UTC to 2016-06-03 02:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 02:54:56 UTC to 2016-06-03 02:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:14:56 UTC to 2016-06-03 03:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:34:56 UTC to 2016-06-03 03:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 03:54:56 UTC to 2016-06-03 03:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:14:56 UTC to 2016-06-03 04:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:34:56 UTC to 2016-06-03 04:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 04:54:56 UTC to 2016-06-03 04:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:14:56 UTC to 2016-06-03 05:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:34:58 UTC to 2016-06-03 05:35:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 05:54:56 UTC to 2016-06-03 05:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:14:56 UTC to 2016-06-03 06:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:34:56 UTC to 2016-06-03 06:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 06:54:56 UTC to 2016-06-03 06:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:14:56 UTC to 2016-06-03 07:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:34:56 UTC to 2016-06-03 07:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 07:54:56 UTC to 2016-06-03 07:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:14:56 UTC to 2016-06-03 08:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:34:56 UTC to 2016-06-03 08:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 08:54:56 UTC to 2016-06-03 08:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:14:56 UTC to 2016-06-03 09:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:34:56 UTC to 2016-06-03 09:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 09:54:56 UTC to 2016-06-03 09:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:14:56 UTC to 2016-06-03 10:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:34:56 UTC to 2016-06-03 10:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 10:54:56 UTC to 2016-06-03 10:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:14:56 UTC to 2016-06-03 11:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:34:56 UTC to 2016-06-03 11:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 11:54:56 UTC to 2016-06-03 11:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:14:56 UTC to 2016-06-03 12:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:34:56 UTC to 2016-06-03 12:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 12:55:14 UTC to 2016-06-03 12:55:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:14:56 UTC to 2016-06-03 13:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:34:56 UTC to 2016-06-03 13:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 13:54:56 UTC to 2016-06-03 13:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 14:34:56 UTC to 2016-06-03 14:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 14:54:56 UTC to 2016-06-03 14:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:14:56 UTC to 2016-06-03 15:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:34:56 UTC to 2016-06-03 15:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 15:54:56 UTC to 2016-06-03 15:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:14:56 UTC to 2016-06-03 16:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:34:56 UTC to 2016-06-03 16:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 16:54:56 UTC to 2016-06-03 16:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:14:57 UTC to 2016-06-03 17:15:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:35:03 UTC to 2016-06-03 17:35:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 17:54:56 UTC to 2016-06-03 17:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:14:56 UTC to 2016-06-03 18:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:34:56 UTC to 2016-06-03 18:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 18:54:56 UTC to 2016-06-03 18:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:14:56 UTC to 2016-06-03 19:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:34:56 UTC to 2016-06-03 19:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 19:54:56 UTC to 2016-06-03 19:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:14:56 UTC to 2016-06-03 20:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:34:56 UTC to 2016-06-03 20:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 20:54:55 UTC to 2016-06-03 20:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:14:55 UTC to 2016-06-03 21:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:34:55 UTC to 2016-06-03 21:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 21:54:58 UTC to 2016-06-03 21:55:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:14:56 UTC to 2016-06-03 22:15:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:34:59 UTC to 2016-06-03 22:35:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 22:54:55 UTC to 2016-06-03 22:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:14:55 UTC to 2016-06-03 23:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:34:55 UTC to 2016-06-03 23:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-03 23:54:56 UTC to 2016-06-03 23:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:14:55 UTC to 2016-06-04 00:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:34:55 UTC to 2016-06-04 00:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 00:54:56 UTC to 2016-06-04 00:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:14:55 UTC to 2016-06-04 01:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:34:56 UTC to 2016-06-04 01:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 01:54:56 UTC to 2016-06-04 01:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:14:55 UTC to 2016-06-04 02:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:34:56 UTC to 2016-06-04 02:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 02:54:55 UTC to 2016-06-04 02:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:14:55 UTC to 2016-06-04 03:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:34:55 UTC to 2016-06-04 03:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 03:54:56 UTC to 2016-06-04 03:55:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:14:55 UTC to 2016-06-04 04:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:34:55 UTC to 2016-06-04 04:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 04:54:55 UTC to 2016-06-04 04:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:14:55 UTC to 2016-06-04 05:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:34:55 UTC to 2016-06-04 05:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 05:54:55 UTC to 2016-06-04 05:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:14:55 UTC to 2016-06-04 06:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:34:55 UTC to 2016-06-04 06:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 06:54:55 UTC to 2016-06-04 06:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:14:55 UTC to 2016-06-04 07:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:34:55 UTC to 2016-06-04 07:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 07:54:57 UTC to 2016-06-04 07:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:14:55 UTC to 2016-06-04 08:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:34:55 UTC to 2016-06-04 08:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 08:54:55 UTC to 2016-06-04 08:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:14:55 UTC to 2016-06-04 09:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:34:55 UTC to 2016-06-04 09:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 09:54:55 UTC to 2016-06-04 09:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:14:55 UTC to 2016-06-04 10:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:34:55 UTC to 2016-06-04 10:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 10:54:55 UTC to 2016-06-04 10:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:14:55 UTC to 2016-06-04 11:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:34:55 UTC to 2016-06-04 11:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 11:54:55 UTC to 2016-06-04 11:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:14:55 UTC to 2016-06-04 12:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:34:55 UTC to 2016-06-04 12:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 12:54:55 UTC to 2016-06-04 12:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:14:55 UTC to 2016-06-04 13:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:34:55 UTC to 2016-06-04 13:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 13:54:55 UTC to 2016-06-04 13:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:14:55 UTC to 2016-06-04 14:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:34:55 UTC to 2016-06-04 14:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 14:54:55 UTC to 2016-06-04 14:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:14:55 UTC to 2016-06-04 15:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:34:55 UTC to 2016-06-04 15:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 15:54:55 UTC to 2016-06-04 15:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:14:55 UTC to 2016-06-04 16:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:34:55 UTC to 2016-06-04 16:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 16:54:55 UTC to 2016-06-04 16:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:14:55 UTC to 2016-06-04 17:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:34:55 UTC to 2016-06-04 17:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 17:54:55 UTC to 2016-06-04 17:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:14:55 UTC to 2016-06-04 18:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:34:55 UTC to 2016-06-04 18:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 18:54:57 UTC to 2016-06-04 18:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:14:55 UTC to 2016-06-04 19:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:34:55 UTC to 2016-06-04 19:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 19:54:55 UTC to 2016-06-04 19:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:14:55 UTC to 2016-06-04 20:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:34:55 UTC to 2016-06-04 20:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 20:54:55 UTC to 2016-06-04 20:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:14:55 UTC to 2016-06-04 21:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:35:05 UTC to 2016-06-04 21:35:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 21:54:55 UTC to 2016-06-04 21:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:14:55 UTC to 2016-06-04 22:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:34:55 UTC to 2016-06-04 22:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 22:54:54 UTC to 2016-06-04 22:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:14:54 UTC to 2016-06-04 23:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:34:55 UTC to 2016-06-04 23:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-04 23:54:55 UTC to 2016-06-04 23:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:14:55 UTC to 2016-06-05 00:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:34:54 UTC to 2016-06-05 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 00:54:54 UTC to 2016-06-05 00:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:14:55 UTC to 2016-06-05 01:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:34:54 UTC to 2016-06-05 01:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 01:54:55 UTC to 2016-06-05 01:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:14:54 UTC to 2016-06-05 02:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:34:54 UTC to 2016-06-05 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 02:54:54 UTC to 2016-06-05 02:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:14:54 UTC to 2016-06-05 03:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:34:55 UTC to 2016-06-05 03:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 03:54:54 UTC to 2016-06-05 03:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:14:54 UTC to 2016-06-05 04:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:34:55 UTC to 2016-06-05 04:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 04:54:54 UTC to 2016-06-05 04:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:14:54 UTC to 2016-06-05 05:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:34:54 UTC to 2016-06-05 05:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 05:54:54 UTC to 2016-06-05 05:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:14:54 UTC to 2016-06-05 06:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:34:54 UTC to 2016-06-05 06:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 06:54:55 UTC to 2016-06-05 06:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 07:14:54 UTC to 2016-06-05 07:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 07:34:54 UTC to 2016-06-05 07:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:14:54 UTC to 2016-06-05 08:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:34:54 UTC to 2016-06-05 08:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 08:54:54 UTC to 2016-06-05 08:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:14:54 UTC to 2016-06-05 09:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:34:55 UTC to 2016-06-05 09:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 09:54:54 UTC to 2016-06-05 09:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:14:54 UTC to 2016-06-05 10:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:34:55 UTC to 2016-06-05 10:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 10:54:59 UTC to 2016-06-05 10:55:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:14:54 UTC to 2016-06-05 11:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:34:54 UTC to 2016-06-05 11:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 11:54:54 UTC to 2016-06-05 11:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:14:54 UTC to 2016-06-05 12:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:34:54 UTC to 2016-06-05 12:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 12:54:57 UTC to 2016-06-05 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 13:14:54 UTC to 2016-06-05 13:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 13:54:54 UTC to 2016-06-05 13:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:14:54 UTC to 2016-06-05 14:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:34:54 UTC to 2016-06-05 14:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 14:54:54 UTC to 2016-06-05 14:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:14:54 UTC to 2016-06-05 15:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:34:54 UTC to 2016-06-05 15:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 15:54:54 UTC to 2016-06-05 15:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:14:54 UTC to 2016-06-05 16:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:34:54 UTC to 2016-06-05 16:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 16:54:54 UTC to 2016-06-05 16:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:14:54 UTC to 2016-06-05 17:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:34:54 UTC to 2016-06-05 17:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 17:54:54 UTC to 2016-06-05 17:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:14:54 UTC to 2016-06-05 18:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:34:54 UTC to 2016-06-05 18:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 18:54:54 UTC to 2016-06-05 18:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:14:54 UTC to 2016-06-05 19:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:34:54 UTC to 2016-06-05 19:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 19:54:54 UTC to 2016-06-05 19:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:14:54 UTC to 2016-06-05 20:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:34:54 UTC to 2016-06-05 20:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 20:54:54 UTC to 2016-06-05 20:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:14:54 UTC to 2016-06-05 21:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:34:54 UTC to 2016-06-05 21:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 21:54:54 UTC to 2016-06-05 21:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:14:54 UTC to 2016-06-05 22:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:34:54 UTC to 2016-06-05 22:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 22:54:54 UTC to 2016-06-05 22:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:14:54 UTC to 2016-06-05 23:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:34:54 UTC to 2016-06-05 23:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-05 23:54:54 UTC to 2016-06-05 23:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:14:54 UTC to 2016-06-06 00:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:34:54 UTC to 2016-06-06 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 00:54:54 UTC to 2016-06-06 00:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:14:54 UTC to 2016-06-06 01:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:34:54 UTC to 2016-06-06 01:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 01:54:54 UTC to 2016-06-06 01:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:14:53 UTC to 2016-06-06 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:34:54 UTC to 2016-06-06 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 02:54:54 UTC to 2016-06-06 02:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 03:14:54 UTC to 2016-06-06 03:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 03:54:54 UTC to 2016-06-06 03:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:14:53 UTC to 2016-06-06 04:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:34:53 UTC to 2016-06-06 04:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 04:54:53 UTC to 2016-06-06 04:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:14:53 UTC to 2016-06-06 05:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:34:53 UTC to 2016-06-06 05:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 05:54:53 UTC to 2016-06-06 05:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:14:53 UTC to 2016-06-06 06:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:34:53 UTC to 2016-06-06 06:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 06:54:53 UTC to 2016-06-06 06:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:14:53 UTC to 2016-06-06 07:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:34:53 UTC to 2016-06-06 07:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 07:54:53 UTC to 2016-06-06 07:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:14:53 UTC to 2016-06-06 08:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:34:53 UTC to 2016-06-06 08:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 08:54:53 UTC to 2016-06-06 08:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:14:55 UTC to 2016-06-06 09:15:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:34:53 UTC to 2016-06-06 09:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 09:54:53 UTC to 2016-06-06 09:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:14:53 UTC to 2016-06-06 10:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:34:53 UTC to 2016-06-06 10:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 10:54:53 UTC to 2016-06-06 10:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:14:54 UTC to 2016-06-06 11:15:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:34:53 UTC to 2016-06-06 11:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 11:54:53 UTC to 2016-06-06 11:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:14:53 UTC to 2016-06-06 12:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:34:53 UTC to 2016-06-06 12:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 12:54:54 UTC to 2016-06-06 12:55:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:14:53 UTC to 2016-06-06 13:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:34:53 UTC to 2016-06-06 13:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 13:54:53 UTC to 2016-06-06 13:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:14:53 UTC to 2016-06-06 14:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:34:53 UTC to 2016-06-06 14:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 14:54:53 UTC to 2016-06-06 14:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:14:53 UTC to 2016-06-06 15:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:34:53 UTC to 2016-06-06 15:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 15:54:53 UTC to 2016-06-06 15:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:14:53 UTC to 2016-06-06 16:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:34:53 UTC to 2016-06-06 16:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 16:54:53 UTC to 2016-06-06 16:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:14:53 UTC to 2016-06-06 17:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:34:53 UTC to 2016-06-06 17:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 17:54:53 UTC to 2016-06-06 17:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:14:53 UTC to 2016-06-06 18:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:34:53 UTC to 2016-06-06 18:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 18:54:53 UTC to 2016-06-06 18:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:14:53 UTC to 2016-06-06 19:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:34:53 UTC to 2016-06-06 19:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 19:54:53 UTC to 2016-06-06 19:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:14:53 UTC to 2016-06-06 20:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:34:53 UTC to 2016-06-06 20:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 20:54:53 UTC to 2016-06-06 20:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:14:53 UTC to 2016-06-06 21:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:34:53 UTC to 2016-06-06 21:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 21:54:53 UTC to 2016-06-06 21:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 22:14:53 UTC to 2016-06-06 22:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-06 22:35:05 UTC to 2016-06-06 22:35:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:15:01 UTC to 2016-06-07 00:15:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:34:56 UTC to 2016-06-07 00:35:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 00:54:57 UTC to 2016-06-07 00:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 01:34:53 UTC to 2016-06-07 01:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 01:54:55 UTC to 2016-06-07 01:55:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:14:53 UTC to 2016-06-07 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:34:53 UTC to 2016-06-07 02:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 02:54:53 UTC to 2016-06-07 02:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:14:53 UTC to 2016-06-07 03:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:34:53 UTC to 2016-06-07 03:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 03:54:53 UTC to 2016-06-07 03:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:14:52 UTC to 2016-06-07 04:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:34:53 UTC to 2016-06-07 04:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 04:54:53 UTC to 2016-06-07 04:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:14:52 UTC to 2016-06-07 05:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:34:53 UTC to 2016-06-07 05:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 05:54:52 UTC to 2016-06-07 05:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:14:52 UTC to 2016-06-07 06:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:34:52 UTC to 2016-06-07 06:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 06:54:52 UTC to 2016-06-07 06:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:14:52 UTC to 2016-06-07 07:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:34:52 UTC to 2016-06-07 07:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 07:54:52 UTC to 2016-06-07 07:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:14:52 UTC to 2016-06-07 08:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:34:52 UTC to 2016-06-07 08:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 08:54:52 UTC to 2016-06-07 08:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:14:52 UTC to 2016-06-07 09:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:34:52 UTC to 2016-06-07 09:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 09:54:52 UTC to 2016-06-07 09:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:14:52 UTC to 2016-06-07 10:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:34:52 UTC to 2016-06-07 10:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 10:54:53 UTC to 2016-06-07 10:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:14:52 UTC to 2016-06-07 11:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:34:52 UTC to 2016-06-07 11:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 11:54:52 UTC to 2016-06-07 11:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:14:52 UTC to 2016-06-07 12:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:34:52 UTC to 2016-06-07 12:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 12:54:57 UTC to 2016-06-07 12:55:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:14:52 UTC to 2016-06-07 13:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:34:52 UTC to 2016-06-07 13:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 13:54:52 UTC to 2016-06-07 13:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:14:52 UTC to 2016-06-07 14:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:34:52 UTC to 2016-06-07 14:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 14:54:52 UTC to 2016-06-07 14:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:14:53 UTC to 2016-06-07 15:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:34:52 UTC to 2016-06-07 15:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 15:54:52 UTC to 2016-06-07 15:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:14:52 UTC to 2016-06-07 16:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:34:53 UTC to 2016-06-07 16:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 16:54:52 UTC to 2016-06-07 16:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:14:52 UTC to 2016-06-07 17:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:36:08 UTC to 2016-06-07 17:36:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 17:54:52 UTC to 2016-06-07 17:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:14:52 UTC to 2016-06-07 18:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:34:52 UTC to 2016-06-07 18:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 18:54:53 UTC to 2016-06-07 18:55:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:14:52 UTC to 2016-06-07 19:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:34:52 UTC to 2016-06-07 19:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 19:54:52 UTC to 2016-06-07 19:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:14:52 UTC to 2016-06-07 20:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:34:52 UTC to 2016-06-07 20:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 20:54:52 UTC to 2016-06-07 20:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:14:52 UTC to 2016-06-07 21:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:34:52 UTC to 2016-06-07 21:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 21:54:52 UTC to 2016-06-07 21:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:14:52 UTC to 2016-06-07 22:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:34:52 UTC to 2016-06-07 22:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 22:54:52 UTC to 2016-06-07 22:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:14:52 UTC to 2016-06-07 23:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:34:53 UTC to 2016-06-07 23:35:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-07 23:55:06 UTC to 2016-06-07 23:55:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:14:52 UTC to 2016-06-08 00:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:34:54 UTC to 2016-06-08 00:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 00:54:52 UTC to 2016-06-08 00:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:14:52 UTC to 2016-06-08 01:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:34:55 UTC to 2016-06-08 01:35:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 01:54:52 UTC to 2016-06-08 01:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:14:53 UTC to 2016-06-08 02:15:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:34:54 UTC to 2016-06-08 02:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 02:55:08 UTC to 2016-06-08 02:55:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:14:52 UTC to 2016-06-08 03:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:34:52 UTC to 2016-06-08 03:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 03:54:52 UTC to 2016-06-08 03:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:14:52 UTC to 2016-06-08 04:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:34:52 UTC to 2016-06-08 04:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 04:54:52 UTC to 2016-06-08 04:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:14:52 UTC to 2016-06-08 05:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:34:52 UTC to 2016-06-08 05:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 05:54:52 UTC to 2016-06-08 05:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:14:52 UTC to 2016-06-08 06:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:34:52 UTC to 2016-06-08 06:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 06:54:52 UTC to 2016-06-08 06:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:14:52 UTC to 2016-06-08 07:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:34:52 UTC to 2016-06-08 07:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 07:54:52 UTC to 2016-06-08 07:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:14:52 UTC to 2016-06-08 08:15:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:34:52 UTC to 2016-06-08 08:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 08:54:52 UTC to 2016-06-08 08:55:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:14:51 UTC to 2016-06-08 09:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:34:52 UTC to 2016-06-08 09:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 09:54:51 UTC to 2016-06-08 09:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:14:51 UTC to 2016-06-08 10:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:34:51 UTC to 2016-06-08 10:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 10:54:51 UTC to 2016-06-08 10:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:14:51 UTC to 2016-06-08 11:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:34:51 UTC to 2016-06-08 11:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 11:54:51 UTC to 2016-06-08 11:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:14:51 UTC to 2016-06-08 12:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:34:51 UTC to 2016-06-08 12:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 12:54:51 UTC to 2016-06-08 12:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:14:51 UTC to 2016-06-08 13:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:34:51 UTC to 2016-06-08 13:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 13:54:51 UTC to 2016-06-08 13:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:14:51 UTC to 2016-06-08 14:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:34:51 UTC to 2016-06-08 14:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 14:54:51 UTC to 2016-06-08 14:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:14:51 UTC to 2016-06-08 15:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:34:51 UTC to 2016-06-08 15:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 15:54:51 UTC to 2016-06-08 15:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:14:51 UTC to 2016-06-08 16:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:34:51 UTC to 2016-06-08 16:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 16:54:51 UTC to 2016-06-08 16:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:14:51 UTC to 2016-06-08 17:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:34:51 UTC to 2016-06-08 17:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 17:54:51 UTC to 2016-06-08 17:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:14:51 UTC to 2016-06-08 18:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:34:51 UTC to 2016-06-08 18:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 18:54:51 UTC to 2016-06-08 18:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:14:51 UTC to 2016-06-08 19:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:34:51 UTC to 2016-06-08 19:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 19:54:51 UTC to 2016-06-08 19:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:14:51 UTC to 2016-06-08 20:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:34:52 UTC to 2016-06-08 20:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 20:54:51 UTC to 2016-06-08 20:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:14:51 UTC to 2016-06-08 21:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:34:51 UTC to 2016-06-08 21:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 21:54:51 UTC to 2016-06-08 21:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:14:51 UTC to 2016-06-08 22:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:34:51 UTC to 2016-06-08 22:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 22:54:51 UTC to 2016-06-08 22:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:14:51 UTC to 2016-06-08 23:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:34:51 UTC to 2016-06-08 23:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-08 23:54:51 UTC to 2016-06-08 23:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:14:51 UTC to 2016-06-09 00:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:34:51 UTC to 2016-06-09 00:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 00:54:51 UTC to 2016-06-09 00:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:14:51 UTC to 2016-06-09 01:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:34:51 UTC to 2016-06-09 01:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 01:54:51 UTC to 2016-06-09 01:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:14:51 UTC to 2016-06-09 02:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:34:51 UTC to 2016-06-09 02:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 02:54:51 UTC to 2016-06-09 02:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:14:51 UTC to 2016-06-09 03:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:34:51 UTC to 2016-06-09 03:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 03:54:51 UTC to 2016-06-09 03:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:14:51 UTC to 2016-06-09 04:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:34:51 UTC to 2016-06-09 04:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 04:54:51 UTC to 2016-06-09 04:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:14:51 UTC to 2016-06-09 05:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:34:51 UTC to 2016-06-09 05:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 05:54:51 UTC to 2016-06-09 05:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:14:51 UTC to 2016-06-09 06:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:34:51 UTC to 2016-06-09 06:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 06:54:51 UTC to 2016-06-09 06:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:14:51 UTC to 2016-06-09 07:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:34:51 UTC to 2016-06-09 07:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 07:54:51 UTC to 2016-06-09 07:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:14:51 UTC to 2016-06-09 08:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:34:51 UTC to 2016-06-09 08:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 08:54:51 UTC to 2016-06-09 08:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:14:51 UTC to 2016-06-09 09:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:34:51 UTC to 2016-06-09 09:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 09:54:51 UTC to 2016-06-09 09:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:14:50 UTC to 2016-06-09 10:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:34:51 UTC to 2016-06-09 10:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 10:54:51 UTC to 2016-06-09 10:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:14:51 UTC to 2016-06-09 11:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:34:51 UTC to 2016-06-09 11:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 11:54:51 UTC to 2016-06-09 11:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:14:50 UTC to 2016-06-09 12:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:34:50 UTC to 2016-06-09 12:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 12:54:50 UTC to 2016-06-09 12:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:14:50 UTC to 2016-06-09 13:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:34:50 UTC to 2016-06-09 13:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 13:54:50 UTC to 2016-06-09 13:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:14:50 UTC to 2016-06-09 14:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:34:50 UTC to 2016-06-09 14:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 14:54:51 UTC to 2016-06-09 14:55:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:14:51 UTC to 2016-06-09 15:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:34:51 UTC to 2016-06-09 15:35:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 15:54:50 UTC to 2016-06-09 15:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:14:50 UTC to 2016-06-09 16:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:34:50 UTC to 2016-06-09 16:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 16:54:50 UTC to 2016-06-09 16:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:14:50 UTC to 2016-06-09 17:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:34:50 UTC to 2016-06-09 17:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 17:54:50 UTC to 2016-06-09 17:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:14:50 UTC to 2016-06-09 18:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:34:50 UTC to 2016-06-09 18:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 18:54:50 UTC to 2016-06-09 18:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:14:51 UTC to 2016-06-09 19:15:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:34:50 UTC to 2016-06-09 19:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 19:54:50 UTC to 2016-06-09 19:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:14:50 UTC to 2016-06-09 20:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:34:50 UTC to 2016-06-09 20:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 20:54:50 UTC to 2016-06-09 20:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:14:50 UTC to 2016-06-09 21:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:34:50 UTC to 2016-06-09 21:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 21:54:50 UTC to 2016-06-09 21:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:14:50 UTC to 2016-06-09 22:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:34:50 UTC to 2016-06-09 22:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 22:54:50 UTC to 2016-06-09 22:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:14:50 UTC to 2016-06-09 23:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:34:50 UTC to 2016-06-09 23:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-09 23:54:50 UTC to 2016-06-09 23:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:14:50 UTC to 2016-06-10 00:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:34:50 UTC to 2016-06-10 00:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 00:54:50 UTC to 2016-06-10 00:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:14:50 UTC to 2016-06-10 01:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:34:50 UTC to 2016-06-10 01:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 01:54:50 UTC to 2016-06-10 01:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:14:50 UTC to 2016-06-10 02:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:34:50 UTC to 2016-06-10 02:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 02:54:50 UTC to 2016-06-10 02:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:14:50 UTC to 2016-06-10 03:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:34:50 UTC to 2016-06-10 03:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 03:54:50 UTC to 2016-06-10 03:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:14:50 UTC to 2016-06-10 04:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:34:50 UTC to 2016-06-10 04:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 04:54:50 UTC to 2016-06-10 04:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:14:50 UTC to 2016-06-10 05:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:34:50 UTC to 2016-06-10 05:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 05:54:50 UTC to 2016-06-10 05:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:14:50 UTC to 2016-06-10 06:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:34:50 UTC to 2016-06-10 06:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 06:54:50 UTC to 2016-06-10 06:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:14:50 UTC to 2016-06-10 07:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:34:50 UTC to 2016-06-10 07:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 07:54:50 UTC to 2016-06-10 07:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:14:50 UTC to 2016-06-10 08:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:34:50 UTC to 2016-06-10 08:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 08:54:50 UTC to 2016-06-10 08:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:14:50 UTC to 2016-06-10 09:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:34:50 UTC to 2016-06-10 09:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 09:54:50 UTC to 2016-06-10 09:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:14:50 UTC to 2016-06-10 10:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:34:50 UTC to 2016-06-10 10:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 10:54:50 UTC to 2016-06-10 10:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:14:50 UTC to 2016-06-10 11:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:34:50 UTC to 2016-06-10 11:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 11:54:50 UTC to 2016-06-10 11:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:14:50 UTC to 2016-06-10 12:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:34:50 UTC to 2016-06-10 12:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 12:54:50 UTC to 2016-06-10 12:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:14:50 UTC to 2016-06-10 13:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:34:50 UTC to 2016-06-10 13:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 13:54:50 UTC to 2016-06-10 13:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:14:49 UTC to 2016-06-10 14:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:34:49 UTC to 2016-06-10 14:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 14:54:50 UTC to 2016-06-10 14:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:14:50 UTC to 2016-06-10 15:15:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:34:49 UTC to 2016-06-10 15:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 15:54:49 UTC to 2016-06-10 15:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:14:49 UTC to 2016-06-10 16:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:34:50 UTC to 2016-06-10 16:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 16:54:49 UTC to 2016-06-10 16:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:14:49 UTC to 2016-06-10 17:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:34:49 UTC to 2016-06-10 17:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 17:54:49 UTC to 2016-06-10 17:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:14:49 UTC to 2016-06-10 18:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:34:50 UTC to 2016-06-10 18:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 18:54:50 UTC to 2016-06-10 18:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:14:49 UTC to 2016-06-10 19:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:34:52 UTC to 2016-06-10 19:35:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 19:54:49 UTC to 2016-06-10 19:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:14:49 UTC to 2016-06-10 20:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:34:49 UTC to 2016-06-10 20:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 20:54:49 UTC to 2016-06-10 20:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:14:49 UTC to 2016-06-10 21:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:34:49 UTC to 2016-06-10 21:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 21:54:49 UTC to 2016-06-10 21:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:14:49 UTC to 2016-06-10 22:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:34:49 UTC to 2016-06-10 22:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 22:54:49 UTC to 2016-06-10 22:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:14:49 UTC to 2016-06-10 23:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:34:49 UTC to 2016-06-10 23:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-10 23:54:49 UTC to 2016-06-10 23:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:14:49 UTC to 2016-06-11 00:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:34:49 UTC to 2016-06-11 00:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 00:54:49 UTC to 2016-06-11 00:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:14:49 UTC to 2016-06-11 01:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:34:49 UTC to 2016-06-11 01:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 01:54:49 UTC to 2016-06-11 01:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:14:49 UTC to 2016-06-11 02:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:34:49 UTC to 2016-06-11 02:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 02:54:49 UTC to 2016-06-11 02:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:14:49 UTC to 2016-06-11 03:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:34:49 UTC to 2016-06-11 03:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 03:54:49 UTC to 2016-06-11 03:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:14:49 UTC to 2016-06-11 04:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:34:49 UTC to 2016-06-11 04:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 04:54:49 UTC to 2016-06-11 04:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:14:49 UTC to 2016-06-11 05:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:34:49 UTC to 2016-06-11 05:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 05:54:49 UTC to 2016-06-11 05:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:14:49 UTC to 2016-06-11 06:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:34:49 UTC to 2016-06-11 06:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 06:54:49 UTC to 2016-06-11 06:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:14:49 UTC to 2016-06-11 07:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:34:49 UTC to 2016-06-11 07:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 07:54:49 UTC to 2016-06-11 07:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:14:49 UTC to 2016-06-11 08:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:34:54 UTC to 2016-06-11 08:35:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 08:54:49 UTC to 2016-06-11 08:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:14:49 UTC to 2016-06-11 09:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:34:49 UTC to 2016-06-11 09:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 09:54:49 UTC to 2016-06-11 09:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:14:49 UTC to 2016-06-11 10:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:34:49 UTC to 2016-06-11 10:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 10:54:49 UTC to 2016-06-11 10:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:14:49 UTC to 2016-06-11 11:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:34:49 UTC to 2016-06-11 11:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 11:54:49 UTC to 2016-06-11 11:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:14:49 UTC to 2016-06-11 12:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:34:49 UTC to 2016-06-11 12:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 12:54:49 UTC to 2016-06-11 12:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:14:49 UTC to 2016-06-11 13:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:34:49 UTC to 2016-06-11 13:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 13:54:49 UTC to 2016-06-11 13:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:14:49 UTC to 2016-06-11 14:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:34:49 UTC to 2016-06-11 14:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 14:54:49 UTC to 2016-06-11 14:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:14:49 UTC to 2016-06-11 15:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:34:49 UTC to 2016-06-11 15:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 15:54:49 UTC to 2016-06-11 15:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:14:49 UTC to 2016-06-11 16:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:34:49 UTC to 2016-06-11 16:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 16:54:49 UTC to 2016-06-11 16:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:14:49 UTC to 2016-06-11 17:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:34:49 UTC to 2016-06-11 17:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 17:54:48 UTC to 2016-06-11 17:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:14:48 UTC to 2016-06-11 18:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:34:49 UTC to 2016-06-11 18:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 18:54:49 UTC to 2016-06-11 18:55:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:14:49 UTC to 2016-06-11 19:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:34:49 UTC to 2016-06-11 19:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 19:54:48 UTC to 2016-06-11 19:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:14:48 UTC to 2016-06-11 20:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:34:48 UTC to 2016-06-11 20:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 20:54:48 UTC to 2016-06-11 20:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:14:48 UTC to 2016-06-11 21:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:34:48 UTC to 2016-06-11 21:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 21:54:48 UTC to 2016-06-11 21:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:14:48 UTC to 2016-06-11 22:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:34:48 UTC to 2016-06-11 22:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 22:54:48 UTC to 2016-06-11 22:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:14:48 UTC to 2016-06-11 23:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:34:49 UTC to 2016-06-11 23:35:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-11 23:54:48 UTC to 2016-06-11 23:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:14:49 UTC to 2016-06-12 00:15:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:34:48 UTC to 2016-06-12 00:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 00:54:48 UTC to 2016-06-12 00:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:14:48 UTC to 2016-06-12 01:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:34:48 UTC to 2016-06-12 01:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 01:54:48 UTC to 2016-06-12 01:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:14:48 UTC to 2016-06-12 02:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:34:48 UTC to 2016-06-12 02:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 02:54:48 UTC to 2016-06-12 02:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:14:48 UTC to 2016-06-12 03:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:34:48 UTC to 2016-06-12 03:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 03:54:48 UTC to 2016-06-12 03:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 04:14:48 UTC to 2016-06-12 04:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 04:54:48 UTC to 2016-06-12 04:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 05:14:48 UTC to 2016-06-12 05:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 05:54:48 UTC to 2016-06-12 05:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:14:48 UTC to 2016-06-12 06:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:34:48 UTC to 2016-06-12 06:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 06:54:48 UTC to 2016-06-12 06:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:14:48 UTC to 2016-06-12 07:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:34:48 UTC to 2016-06-12 07:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 07:54:48 UTC to 2016-06-12 07:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 08:34:48 UTC to 2016-06-12 08:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 08:54:48 UTC to 2016-06-12 08:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:14:48 UTC to 2016-06-12 09:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:34:48 UTC to 2016-06-12 09:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 09:54:48 UTC to 2016-06-12 09:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 10:14:48 UTC to 2016-06-12 10:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 10:34:48 UTC to 2016-06-12 10:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:14:48 UTC to 2016-06-12 11:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:34:48 UTC to 2016-06-12 11:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 11:54:48 UTC to 2016-06-12 11:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:14:48 UTC to 2016-06-12 12:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:34:48 UTC to 2016-06-12 12:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 12:54:48 UTC to 2016-06-12 12:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:14:48 UTC to 2016-06-12 13:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:34:48 UTC to 2016-06-12 13:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 13:54:48 UTC to 2016-06-12 13:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:14:48 UTC to 2016-06-12 14:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:34:48 UTC to 2016-06-12 14:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 14:54:50 UTC to 2016-06-12 14:55:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:14:48 UTC to 2016-06-12 15:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:34:48 UTC to 2016-06-12 15:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 15:54:48 UTC to 2016-06-12 15:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 16:34:48 UTC to 2016-06-12 16:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 16:54:48 UTC to 2016-06-12 16:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:14:48 UTC to 2016-06-12 17:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:34:48 UTC to 2016-06-12 17:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 17:54:48 UTC to 2016-06-12 17:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:14:48 UTC to 2016-06-12 18:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:34:48 UTC to 2016-06-12 18:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 18:54:48 UTC to 2016-06-12 18:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:14:48 UTC to 2016-06-12 19:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:34:48 UTC to 2016-06-12 19:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 19:54:48 UTC to 2016-06-12 19:55:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 20:14:48 UTC to 2016-06-12 20:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 20:34:48 UTC to 2016-06-12 20:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:14:47 UTC to 2016-06-12 21:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:34:48 UTC to 2016-06-12 21:35:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 21:54:47 UTC to 2016-06-12 21:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:14:48 UTC to 2016-06-12 22:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:34:47 UTC to 2016-06-12 22:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 22:54:47 UTC to 2016-06-12 22:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:14:48 UTC to 2016-06-12 23:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:34:47 UTC to 2016-06-12 23:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-12 23:54:47 UTC to 2016-06-12 23:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:14:47 UTC to 2016-06-13 00:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:34:47 UTC to 2016-06-13 00:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 00:54:47 UTC to 2016-06-13 00:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 01:14:47 UTC to 2016-06-13 01:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 01:54:47 UTC to 2016-06-13 01:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:14:47 UTC to 2016-06-13 02:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:34:47 UTC to 2016-06-13 02:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 02:54:47 UTC to 2016-06-13 02:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 03:34:47 UTC to 2016-06-13 03:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 03:54:47 UTC to 2016-06-13 03:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:14:47 UTC to 2016-06-13 04:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:34:47 UTC to 2016-06-13 04:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 04:54:47 UTC to 2016-06-13 04:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:14:48 UTC to 2016-06-13 05:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:34:47 UTC to 2016-06-13 05:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 05:54:47 UTC to 2016-06-13 05:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:14:47 UTC to 2016-06-13 06:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:34:47 UTC to 2016-06-13 06:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 06:54:47 UTC to 2016-06-13 06:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:14:47 UTC to 2016-06-13 07:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:34:47 UTC to 2016-06-13 07:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 07:54:47 UTC to 2016-06-13 07:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:14:47 UTC to 2016-06-13 08:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:34:47 UTC to 2016-06-13 08:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 08:54:47 UTC to 2016-06-13 08:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:14:47 UTC to 2016-06-13 09:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:34:47 UTC to 2016-06-13 09:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 09:54:47 UTC to 2016-06-13 09:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:14:47 UTC to 2016-06-13 10:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:34:47 UTC to 2016-06-13 10:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 10:54:47 UTC to 2016-06-13 10:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:14:47 UTC to 2016-06-13 11:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:34:47 UTC to 2016-06-13 11:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 11:54:47 UTC to 2016-06-13 11:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:14:47 UTC to 2016-06-13 12:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:34:47 UTC to 2016-06-13 12:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 12:54:47 UTC to 2016-06-13 12:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:14:47 UTC to 2016-06-13 13:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:34:47 UTC to 2016-06-13 13:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 13:54:47 UTC to 2016-06-13 13:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 14:14:47 UTC to 2016-06-13 14:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 14:34:50 UTC to 2016-06-13 14:35:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:14:47 UTC to 2016-06-13 15:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:34:47 UTC to 2016-06-13 15:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 15:54:47 UTC to 2016-06-13 15:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:14:47 UTC to 2016-06-13 16:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:34:47 UTC to 2016-06-13 16:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 16:54:47 UTC to 2016-06-13 16:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:14:47 UTC to 2016-06-13 17:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:34:47 UTC to 2016-06-13 17:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 17:54:47 UTC to 2016-06-13 17:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:14:47 UTC to 2016-06-13 18:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:34:47 UTC to 2016-06-13 18:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 18:54:47 UTC to 2016-06-13 18:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:14:47 UTC to 2016-06-13 19:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:34:47 UTC to 2016-06-13 19:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 19:54:47 UTC to 2016-06-13 19:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:14:47 UTC to 2016-06-13 20:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:34:47 UTC to 2016-06-13 20:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 20:54:47 UTC to 2016-06-13 20:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:14:47 UTC to 2016-06-13 21:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:34:47 UTC to 2016-06-13 21:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 21:54:47 UTC to 2016-06-13 21:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:14:47 UTC to 2016-06-13 22:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:34:47 UTC to 2016-06-13 22:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 22:54:47 UTC to 2016-06-13 22:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:14:47 UTC to 2016-06-13 23:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:34:47 UTC to 2016-06-13 23:35:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-13 23:54:47 UTC to 2016-06-13 23:55:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:14:46 UTC to 2016-06-14 00:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:34:46 UTC to 2016-06-14 00:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 00:54:46 UTC to 2016-06-14 00:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:14:46 UTC to 2016-06-14 01:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:34:46 UTC to 2016-06-14 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 01:54:46 UTC to 2016-06-14 01:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:14:46 UTC to 2016-06-14 02:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:34:46 UTC to 2016-06-14 02:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 02:54:46 UTC to 2016-06-14 02:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:14:46 UTC to 2016-06-14 03:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:34:46 UTC to 2016-06-14 03:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 03:54:46 UTC to 2016-06-14 03:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:14:46 UTC to 2016-06-14 04:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:34:46 UTC to 2016-06-14 04:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 04:54:46 UTC to 2016-06-14 04:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:14:46 UTC to 2016-06-14 05:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:34:46 UTC to 2016-06-14 05:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 05:54:46 UTC to 2016-06-14 05:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:14:46 UTC to 2016-06-14 06:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:34:46 UTC to 2016-06-14 06:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 06:54:46 UTC to 2016-06-14 06:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:14:46 UTC to 2016-06-14 07:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:34:46 UTC to 2016-06-14 07:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 07:54:46 UTC to 2016-06-14 07:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:14:46 UTC to 2016-06-14 08:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:34:46 UTC to 2016-06-14 08:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 08:54:46 UTC to 2016-06-14 08:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:14:46 UTC to 2016-06-14 09:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:34:46 UTC to 2016-06-14 09:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 09:54:46 UTC to 2016-06-14 09:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:14:46 UTC to 2016-06-14 10:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:34:46 UTC to 2016-06-14 10:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 10:54:46 UTC to 2016-06-14 10:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:14:46 UTC to 2016-06-14 11:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:34:46 UTC to 2016-06-14 11:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 11:54:46 UTC to 2016-06-14 11:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:14:46 UTC to 2016-06-14 12:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:34:46 UTC to 2016-06-14 12:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 12:54:46 UTC to 2016-06-14 12:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:14:46 UTC to 2016-06-14 13:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:34:46 UTC to 2016-06-14 13:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 13:54:46 UTC to 2016-06-14 13:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:14:46 UTC to 2016-06-14 14:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:34:46 UTC to 2016-06-14 14:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 14:54:46 UTC to 2016-06-14 14:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:14:46 UTC to 2016-06-14 15:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:34:46 UTC to 2016-06-14 15:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 15:54:46 UTC to 2016-06-14 15:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:14:46 UTC to 2016-06-14 16:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:34:46 UTC to 2016-06-14 16:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 16:54:46 UTC to 2016-06-14 16:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:14:46 UTC to 2016-06-14 17:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:34:46 UTC to 2016-06-14 17:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 17:54:46 UTC to 2016-06-14 17:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:14:46 UTC to 2016-06-14 18:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:34:46 UTC to 2016-06-14 18:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 18:54:46 UTC to 2016-06-14 18:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:14:46 UTC to 2016-06-14 19:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:34:46 UTC to 2016-06-14 19:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 19:54:46 UTC to 2016-06-14 19:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:14:46 UTC to 2016-06-14 20:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:34:46 UTC to 2016-06-14 20:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 20:54:46 UTC to 2016-06-14 20:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:14:46 UTC to 2016-06-14 21:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:34:46 UTC to 2016-06-14 21:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 21:54:46 UTC to 2016-06-14 21:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:14:46 UTC to 2016-06-14 22:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:34:46 UTC to 2016-06-14 22:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 22:54:46 UTC to 2016-06-14 22:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:14:46 UTC to 2016-06-14 23:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:34:46 UTC to 2016-06-14 23:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-14 23:54:46 UTC to 2016-06-14 23:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:14:46 UTC to 2016-06-15 00:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:34:46 UTC to 2016-06-15 00:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 00:54:46 UTC to 2016-06-15 00:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:14:46 UTC to 2016-06-15 01:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:34:46 UTC to 2016-06-15 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 01:54:46 UTC to 2016-06-15 01:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:14:46 UTC to 2016-06-15 02:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:34:46 UTC to 2016-06-15 02:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 02:54:46 UTC to 2016-06-15 02:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:14:46 UTC to 2016-06-15 03:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:34:45 UTC to 2016-06-15 03:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 03:54:46 UTC to 2016-06-15 03:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:14:46 UTC to 2016-06-15 04:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:34:46 UTC to 2016-06-15 04:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 04:54:46 UTC to 2016-06-15 04:55:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:14:45 UTC to 2016-06-15 05:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:34:46 UTC to 2016-06-15 05:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 05:54:45 UTC to 2016-06-15 05:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:14:45 UTC to 2016-06-15 06:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:34:45 UTC to 2016-06-15 06:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 06:54:45 UTC to 2016-06-15 06:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:14:45 UTC to 2016-06-15 07:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:34:45 UTC to 2016-06-15 07:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 07:54:45 UTC to 2016-06-15 07:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:14:45 UTC to 2016-06-15 08:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:34:45 UTC to 2016-06-15 08:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 08:54:45 UTC to 2016-06-15 08:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:14:45 UTC to 2016-06-15 09:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:34:45 UTC to 2016-06-15 09:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 09:54:45 UTC to 2016-06-15 09:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:14:45 UTC to 2016-06-15 10:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:34:45 UTC to 2016-06-15 10:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 10:54:45 UTC to 2016-06-15 10:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:14:45 UTC to 2016-06-15 11:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:34:45 UTC to 2016-06-15 11:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 11:54:45 UTC to 2016-06-15 11:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:14:45 UTC to 2016-06-15 12:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:34:45 UTC to 2016-06-15 12:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 12:54:45 UTC to 2016-06-15 12:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:14:45 UTC to 2016-06-15 13:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:34:45 UTC to 2016-06-15 13:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 13:54:45 UTC to 2016-06-15 13:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:14:45 UTC to 2016-06-15 14:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:34:46 UTC to 2016-06-15 14:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 14:54:45 UTC to 2016-06-15 14:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:14:46 UTC to 2016-06-15 15:15:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:34:46 UTC to 2016-06-15 15:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 15:54:45 UTC to 2016-06-15 15:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:14:45 UTC to 2016-06-15 16:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:34:45 UTC to 2016-06-15 16:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 16:54:45 UTC to 2016-06-15 16:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:14:45 UTC to 2016-06-15 17:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:34:45 UTC to 2016-06-15 17:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 17:54:45 UTC to 2016-06-15 17:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:14:45 UTC to 2016-06-15 18:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:34:45 UTC to 2016-06-15 18:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 18:54:45 UTC to 2016-06-15 18:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:14:45 UTC to 2016-06-15 19:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:34:45 UTC to 2016-06-15 19:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 19:54:45 UTC to 2016-06-15 19:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:14:45 UTC to 2016-06-15 20:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:34:45 UTC to 2016-06-15 20:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 20:54:45 UTC to 2016-06-15 20:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:14:48 UTC to 2016-06-15 21:15:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:34:45 UTC to 2016-06-15 21:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 21:54:45 UTC to 2016-06-15 21:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:14:45 UTC to 2016-06-15 22:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:34:45 UTC to 2016-06-15 22:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 22:54:45 UTC to 2016-06-15 22:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:14:45 UTC to 2016-06-15 23:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:34:45 UTC to 2016-06-15 23:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-15 23:55:03 UTC to 2016-06-15 23:55:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:14:45 UTC to 2016-06-16 00:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:34:45 UTC to 2016-06-16 00:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 00:54:45 UTC to 2016-06-16 00:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:14:45 UTC to 2016-06-16 01:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:34:46 UTC to 2016-06-16 01:35:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 01:54:45 UTC to 2016-06-16 01:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:14:45 UTC to 2016-06-16 02:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:34:45 UTC to 2016-06-16 02:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 02:54:45 UTC to 2016-06-16 02:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:14:45 UTC to 2016-06-16 03:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:34:45 UTC to 2016-06-16 03:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 03:54:45 UTC to 2016-06-16 03:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:14:45 UTC to 2016-06-16 04:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:34:45 UTC to 2016-06-16 04:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 04:54:45 UTC to 2016-06-16 04:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:14:45 UTC to 2016-06-16 05:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:34:45 UTC to 2016-06-16 05:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 05:54:45 UTC to 2016-06-16 05:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:14:45 UTC to 2016-06-16 06:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:34:45 UTC to 2016-06-16 06:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 06:54:45 UTC to 2016-06-16 06:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:14:45 UTC to 2016-06-16 07:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:34:45 UTC to 2016-06-16 07:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 07:54:45 UTC to 2016-06-16 07:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:14:44 UTC to 2016-06-16 08:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:34:45 UTC to 2016-06-16 08:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 08:54:45 UTC to 2016-06-16 08:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:14:45 UTC to 2016-06-16 09:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:34:45 UTC to 2016-06-16 09:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 09:54:45 UTC to 2016-06-16 09:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:14:44 UTC to 2016-06-16 10:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:34:44 UTC to 2016-06-16 10:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 10:54:44 UTC to 2016-06-16 10:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:14:45 UTC to 2016-06-16 11:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:34:44 UTC to 2016-06-16 11:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 11:54:44 UTC to 2016-06-16 11:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:14:44 UTC to 2016-06-16 12:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:34:45 UTC to 2016-06-16 12:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 12:54:44 UTC to 2016-06-16 12:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:14:47 UTC to 2016-06-16 13:15:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:34:45 UTC to 2016-06-16 13:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 13:54:44 UTC to 2016-06-16 13:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:14:44 UTC to 2016-06-16 14:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:34:44 UTC to 2016-06-16 14:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 14:54:44 UTC to 2016-06-16 14:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:14:44 UTC to 2016-06-16 15:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:34:45 UTC to 2016-06-16 15:35:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 15:54:45 UTC to 2016-06-16 15:55:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:14:44 UTC to 2016-06-16 16:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:34:44 UTC to 2016-06-16 16:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 16:54:44 UTC to 2016-06-16 16:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:14:44 UTC to 2016-06-16 17:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:34:44 UTC to 2016-06-16 17:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 17:54:44 UTC to 2016-06-16 17:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:14:44 UTC to 2016-06-16 18:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:34:44 UTC to 2016-06-16 18:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 18:54:44 UTC to 2016-06-16 18:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:14:44 UTC to 2016-06-16 19:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:34:44 UTC to 2016-06-16 19:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 19:54:44 UTC to 2016-06-16 19:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:14:44 UTC to 2016-06-16 20:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:34:44 UTC to 2016-06-16 20:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 20:54:44 UTC to 2016-06-16 20:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:14:44 UTC to 2016-06-16 21:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:34:44 UTC to 2016-06-16 21:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 21:54:44 UTC to 2016-06-16 21:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:14:44 UTC to 2016-06-16 22:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:34:44 UTC to 2016-06-16 22:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 22:54:44 UTC to 2016-06-16 22:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:14:44 UTC to 2016-06-16 23:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:34:44 UTC to 2016-06-16 23:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-16 23:54:44 UTC to 2016-06-16 23:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:14:45 UTC to 2016-06-17 00:15:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:34:44 UTC to 2016-06-17 00:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 00:54:44 UTC to 2016-06-17 00:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:14:44 UTC to 2016-06-17 01:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:34:44 UTC to 2016-06-17 01:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 01:54:44 UTC to 2016-06-17 01:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:14:44 UTC to 2016-06-17 02:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:34:44 UTC to 2016-06-17 02:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 02:54:44 UTC to 2016-06-17 02:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:14:44 UTC to 2016-06-17 03:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:34:44 UTC to 2016-06-17 03:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 03:54:44 UTC to 2016-06-17 03:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:14:44 UTC to 2016-06-17 04:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:34:44 UTC to 2016-06-17 04:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 04:54:44 UTC to 2016-06-17 04:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:14:44 UTC to 2016-06-17 05:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:34:44 UTC to 2016-06-17 05:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 05:54:44 UTC to 2016-06-17 05:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:14:44 UTC to 2016-06-17 06:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:34:44 UTC to 2016-06-17 06:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 06:54:44 UTC to 2016-06-17 06:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:14:44 UTC to 2016-06-17 07:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:34:44 UTC to 2016-06-17 07:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 07:54:44 UTC to 2016-06-17 07:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:14:44 UTC to 2016-06-17 08:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:34:44 UTC to 2016-06-17 08:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 08:54:44 UTC to 2016-06-17 08:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:14:44 UTC to 2016-06-17 09:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:34:44 UTC to 2016-06-17 09:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 09:54:44 UTC to 2016-06-17 09:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:14:44 UTC to 2016-06-17 10:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:34:44 UTC to 2016-06-17 10:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 10:54:44 UTC to 2016-06-17 10:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:14:44 UTC to 2016-06-17 11:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:34:44 UTC to 2016-06-17 11:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 11:54:44 UTC to 2016-06-17 11:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:14:43 UTC to 2016-06-17 12:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:34:44 UTC to 2016-06-17 12:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 12:54:44 UTC to 2016-06-17 12:55:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:14:44 UTC to 2016-06-17 13:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:34:43 UTC to 2016-06-17 13:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 13:54:43 UTC to 2016-06-17 13:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:14:43 UTC to 2016-06-17 14:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:34:43 UTC to 2016-06-17 14:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 14:54:43 UTC to 2016-06-17 14:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:14:43 UTC to 2016-06-17 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:34:44 UTC to 2016-06-17 15:35:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 15:54:43 UTC to 2016-06-17 15:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:14:43 UTC to 2016-06-17 16:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:34:43 UTC to 2016-06-17 16:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 16:54:43 UTC to 2016-06-17 16:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:14:43 UTC to 2016-06-17 17:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:34:43 UTC to 2016-06-17 17:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 17:54:43 UTC to 2016-06-17 17:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:14:43 UTC to 2016-06-17 18:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:34:43 UTC to 2016-06-17 18:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 18:54:43 UTC to 2016-06-17 18:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:14:43 UTC to 2016-06-17 19:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:34:43 UTC to 2016-06-17 19:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 19:54:43 UTC to 2016-06-17 19:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:14:43 UTC to 2016-06-17 20:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:34:43 UTC to 2016-06-17 20:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 20:54:43 UTC to 2016-06-17 20:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:14:43 UTC to 2016-06-17 21:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:34:43 UTC to 2016-06-17 21:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 21:54:43 UTC to 2016-06-17 21:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:14:43 UTC to 2016-06-17 22:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:34:43 UTC to 2016-06-17 22:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 22:54:43 UTC to 2016-06-17 22:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:14:43 UTC to 2016-06-17 23:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:34:43 UTC to 2016-06-17 23:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-17 23:54:43 UTC to 2016-06-17 23:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:14:43 UTC to 2016-06-18 00:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:34:43 UTC to 2016-06-18 00:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 00:54:43 UTC to 2016-06-18 00:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:14:43 UTC to 2016-06-18 01:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:34:43 UTC to 2016-06-18 01:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 01:54:43 UTC to 2016-06-18 01:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:14:43 UTC to 2016-06-18 02:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:34:43 UTC to 2016-06-18 02:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 02:54:43 UTC to 2016-06-18 02:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:14:43 UTC to 2016-06-18 03:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:34:43 UTC to 2016-06-18 03:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 03:54:43 UTC to 2016-06-18 03:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:14:43 UTC to 2016-06-18 04:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:34:43 UTC to 2016-06-18 04:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 04:54:43 UTC to 2016-06-18 04:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:14:43 UTC to 2016-06-18 05:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:34:43 UTC to 2016-06-18 05:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 05:54:43 UTC to 2016-06-18 05:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:14:43 UTC to 2016-06-18 06:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:34:43 UTC to 2016-06-18 06:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 06:54:43 UTC to 2016-06-18 06:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:14:43 UTC to 2016-06-18 07:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:34:43 UTC to 2016-06-18 07:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 07:54:43 UTC to 2016-06-18 07:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:14:43 UTC to 2016-06-18 08:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:34:43 UTC to 2016-06-18 08:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 08:54:43 UTC to 2016-06-18 08:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:14:43 UTC to 2016-06-18 09:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:34:43 UTC to 2016-06-18 09:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 09:54:43 UTC to 2016-06-18 09:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:14:43 UTC to 2016-06-18 10:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:34:43 UTC to 2016-06-18 10:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 10:54:43 UTC to 2016-06-18 10:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:14:43 UTC to 2016-06-18 11:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:34:43 UTC to 2016-06-18 11:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 11:54:43 UTC to 2016-06-18 11:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:14:43 UTC to 2016-06-18 12:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:34:43 UTC to 2016-06-18 12:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 12:54:43 UTC to 2016-06-18 12:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:14:43 UTC to 2016-06-18 13:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:34:43 UTC to 2016-06-18 13:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 13:54:43 UTC to 2016-06-18 13:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:14:43 UTC to 2016-06-18 14:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:34:43 UTC to 2016-06-18 14:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 14:54:43 UTC to 2016-06-18 14:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:14:43 UTC to 2016-06-18 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:34:43 UTC to 2016-06-18 15:35:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 15:54:43 UTC to 2016-06-18 15:55:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:14:44 UTC to 2016-06-18 16:15:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:34:42 UTC to 2016-06-18 16:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 16:54:42 UTC to 2016-06-18 16:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:14:42 UTC to 2016-06-18 17:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:34:42 UTC to 2016-06-18 17:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 17:54:42 UTC to 2016-06-18 17:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:14:42 UTC to 2016-06-18 18:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:34:42 UTC to 2016-06-18 18:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 18:54:42 UTC to 2016-06-18 18:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:14:42 UTC to 2016-06-18 19:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:34:42 UTC to 2016-06-18 19:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 19:54:42 UTC to 2016-06-18 19:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:14:42 UTC to 2016-06-18 20:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:34:42 UTC to 2016-06-18 20:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 20:54:42 UTC to 2016-06-18 20:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:14:42 UTC to 2016-06-18 21:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:34:42 UTC to 2016-06-18 21:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 21:54:42 UTC to 2016-06-18 21:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:14:42 UTC to 2016-06-18 22:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:34:42 UTC to 2016-06-18 22:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 22:54:42 UTC to 2016-06-18 22:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:14:42 UTC to 2016-06-18 23:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:34:42 UTC to 2016-06-18 23:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-18 23:54:42 UTC to 2016-06-18 23:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:14:42 UTC to 2016-06-19 00:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:34:42 UTC to 2016-06-19 00:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 00:54:42 UTC to 2016-06-19 00:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:14:42 UTC to 2016-06-19 01:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:34:42 UTC to 2016-06-19 01:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 01:54:42 UTC to 2016-06-19 01:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:14:42 UTC to 2016-06-19 02:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:34:42 UTC to 2016-06-19 02:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 02:54:42 UTC to 2016-06-19 02:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:14:42 UTC to 2016-06-19 03:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:34:42 UTC to 2016-06-19 03:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 03:54:42 UTC to 2016-06-19 03:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:14:42 UTC to 2016-06-19 04:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:34:42 UTC to 2016-06-19 04:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 04:54:42 UTC to 2016-06-19 04:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:14:42 UTC to 2016-06-19 05:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:34:42 UTC to 2016-06-19 05:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 05:54:42 UTC to 2016-06-19 05:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:14:42 UTC to 2016-06-19 06:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:34:42 UTC to 2016-06-19 06:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 06:54:42 UTC to 2016-06-19 06:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:14:42 UTC to 2016-06-19 07:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:34:42 UTC to 2016-06-19 07:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 07:54:42 UTC to 2016-06-19 07:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:14:42 UTC to 2016-06-19 08:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:34:42 UTC to 2016-06-19 08:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 08:54:42 UTC to 2016-06-19 08:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:14:42 UTC to 2016-06-19 09:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:34:42 UTC to 2016-06-19 09:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 09:54:42 UTC to 2016-06-19 09:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:14:42 UTC to 2016-06-19 10:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:34:42 UTC to 2016-06-19 10:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 10:54:42 UTC to 2016-06-19 10:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:14:42 UTC to 2016-06-19 11:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:34:42 UTC to 2016-06-19 11:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 11:54:42 UTC to 2016-06-19 11:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:14:42 UTC to 2016-06-19 12:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:34:42 UTC to 2016-06-19 12:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 12:54:42 UTC to 2016-06-19 12:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:14:42 UTC to 2016-06-19 13:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:34:42 UTC to 2016-06-19 13:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 13:54:42 UTC to 2016-06-19 13:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:14:42 UTC to 2016-06-19 14:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:34:42 UTC to 2016-06-19 14:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 14:54:42 UTC to 2016-06-19 14:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:14:43 UTC to 2016-06-19 15:15:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:34:42 UTC to 2016-06-19 15:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 15:54:42 UTC to 2016-06-19 15:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:14:42 UTC to 2016-06-19 16:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:34:42 UTC to 2016-06-19 16:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 16:54:42 UTC to 2016-06-19 16:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:14:42 UTC to 2016-06-19 17:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:34:42 UTC to 2016-06-19 17:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 17:54:42 UTC to 2016-06-19 17:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:14:42 UTC to 2016-06-19 18:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:34:42 UTC to 2016-06-19 18:35:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 18:54:42 UTC to 2016-06-19 18:55:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:14:42 UTC to 2016-06-19 19:15:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:34:41 UTC to 2016-06-19 19:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 19:54:41 UTC to 2016-06-19 19:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:14:41 UTC to 2016-06-19 20:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:34:41 UTC to 2016-06-19 20:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 20:54:41 UTC to 2016-06-19 20:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:14:41 UTC to 2016-06-19 21:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:34:41 UTC to 2016-06-19 21:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 21:54:41 UTC to 2016-06-19 21:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:14:41 UTC to 2016-06-19 22:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:34:41 UTC to 2016-06-19 22:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 22:54:41 UTC to 2016-06-19 22:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:14:41 UTC to 2016-06-19 23:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:34:41 UTC to 2016-06-19 23:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-19 23:54:41 UTC to 2016-06-19 23:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:14:41 UTC to 2016-06-20 00:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:34:41 UTC to 2016-06-20 00:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 00:54:41 UTC to 2016-06-20 00:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:14:41 UTC to 2016-06-20 01:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:34:41 UTC to 2016-06-20 01:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 01:54:41 UTC to 2016-06-20 01:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:14:41 UTC to 2016-06-20 02:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:34:41 UTC to 2016-06-20 02:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 02:54:41 UTC to 2016-06-20 02:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:14:41 UTC to 2016-06-20 03:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:34:41 UTC to 2016-06-20 03:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 03:54:41 UTC to 2016-06-20 03:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:14:41 UTC to 2016-06-20 04:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:34:41 UTC to 2016-06-20 04:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 04:54:41 UTC to 2016-06-20 04:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:14:41 UTC to 2016-06-20 05:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:34:41 UTC to 2016-06-20 05:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 05:54:41 UTC to 2016-06-20 05:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:14:41 UTC to 2016-06-20 06:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:34:41 UTC to 2016-06-20 06:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 06:54:41 UTC to 2016-06-20 06:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:14:41 UTC to 2016-06-20 07:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:34:41 UTC to 2016-06-20 07:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 07:54:41 UTC to 2016-06-20 07:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:14:41 UTC to 2016-06-20 08:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:34:41 UTC to 2016-06-20 08:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 08:54:41 UTC to 2016-06-20 08:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:14:41 UTC to 2016-06-20 09:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:34:41 UTC to 2016-06-20 09:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 09:54:41 UTC to 2016-06-20 09:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:14:41 UTC to 2016-06-20 10:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:34:41 UTC to 2016-06-20 10:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 10:54:41 UTC to 2016-06-20 10:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:14:41 UTC to 2016-06-20 11:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:34:41 UTC to 2016-06-20 11:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 11:54:41 UTC to 2016-06-20 11:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:14:41 UTC to 2016-06-20 12:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:34:41 UTC to 2016-06-20 12:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 12:54:41 UTC to 2016-06-20 12:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:14:41 UTC to 2016-06-20 13:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:34:41 UTC to 2016-06-20 13:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 13:54:41 UTC to 2016-06-20 13:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:14:41 UTC to 2016-06-20 14:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:34:41 UTC to 2016-06-20 14:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 14:54:41 UTC to 2016-06-20 14:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:14:41 UTC to 2016-06-20 15:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:34:41 UTC to 2016-06-20 15:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 15:54:41 UTC to 2016-06-20 15:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:14:41 UTC to 2016-06-20 16:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:34:41 UTC to 2016-06-20 16:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 16:54:41 UTC to 2016-06-20 16:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:14:41 UTC to 2016-06-20 17:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:34:41 UTC to 2016-06-20 17:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 17:54:41 UTC to 2016-06-20 17:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:14:41 UTC to 2016-06-20 18:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:34:41 UTC to 2016-06-20 18:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 18:54:41 UTC to 2016-06-20 18:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:14:41 UTC to 2016-06-20 19:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:34:41 UTC to 2016-06-20 19:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 19:54:41 UTC to 2016-06-20 19:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:14:41 UTC to 2016-06-20 20:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:34:41 UTC to 2016-06-20 20:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 20:54:41 UTC to 2016-06-20 20:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:14:41 UTC to 2016-06-20 21:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:34:41 UTC to 2016-06-20 21:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 21:54:41 UTC to 2016-06-20 21:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:14:40 UTC to 2016-06-20 22:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:34:40 UTC to 2016-06-20 22:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 22:54:41 UTC to 2016-06-20 22:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:14:41 UTC to 2016-06-20 23:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:34:41 UTC to 2016-06-20 23:35:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-20 23:54:41 UTC to 2016-06-20 23:55:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:14:41 UTC to 2016-06-21 00:15:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:34:40 UTC to 2016-06-21 00:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 00:54:40 UTC to 2016-06-21 00:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:14:40 UTC to 2016-06-21 01:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:34:40 UTC to 2016-06-21 01:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 01:54:40 UTC to 2016-06-21 01:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:14:40 UTC to 2016-06-21 02:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:34:40 UTC to 2016-06-21 02:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 02:54:40 UTC to 2016-06-21 02:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:14:40 UTC to 2016-06-21 03:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:34:40 UTC to 2016-06-21 03:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 03:54:40 UTC to 2016-06-21 03:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:14:40 UTC to 2016-06-21 04:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:34:40 UTC to 2016-06-21 04:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 04:54:40 UTC to 2016-06-21 04:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:14:40 UTC to 2016-06-21 05:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:34:40 UTC to 2016-06-21 05:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 05:54:40 UTC to 2016-06-21 05:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:14:40 UTC to 2016-06-21 06:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:34:40 UTC to 2016-06-21 06:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 06:54:40 UTC to 2016-06-21 06:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:14:40 UTC to 2016-06-21 07:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:34:40 UTC to 2016-06-21 07:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 07:54:40 UTC to 2016-06-21 07:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:14:40 UTC to 2016-06-21 08:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:34:40 UTC to 2016-06-21 08:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 08:54:40 UTC to 2016-06-21 08:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:14:40 UTC to 2016-06-21 09:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:34:40 UTC to 2016-06-21 09:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 09:54:40 UTC to 2016-06-21 09:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:14:40 UTC to 2016-06-21 10:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:34:40 UTC to 2016-06-21 10:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 10:54:40 UTC to 2016-06-21 10:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:14:40 UTC to 2016-06-21 11:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:34:40 UTC to 2016-06-21 11:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 11:54:40 UTC to 2016-06-21 11:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:14:40 UTC to 2016-06-21 12:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:34:40 UTC to 2016-06-21 12:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 12:54:40 UTC to 2016-06-21 12:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:14:40 UTC to 2016-06-21 13:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:34:40 UTC to 2016-06-21 13:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 13:54:40 UTC to 2016-06-21 13:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:14:40 UTC to 2016-06-21 14:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:34:40 UTC to 2016-06-21 14:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 14:54:40 UTC to 2016-06-21 14:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:14:40 UTC to 2016-06-21 15:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:34:40 UTC to 2016-06-21 15:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 15:54:40 UTC to 2016-06-21 15:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:14:40 UTC to 2016-06-21 16:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:34:40 UTC to 2016-06-21 16:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 16:54:40 UTC to 2016-06-21 16:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:14:40 UTC to 2016-06-21 17:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:34:40 UTC to 2016-06-21 17:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 17:54:40 UTC to 2016-06-21 17:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:14:40 UTC to 2016-06-21 18:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:34:40 UTC to 2016-06-21 18:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 18:54:40 UTC to 2016-06-21 18:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:14:40 UTC to 2016-06-21 19:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:34:40 UTC to 2016-06-21 19:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 19:54:40 UTC to 2016-06-21 19:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:14:40 UTC to 2016-06-21 20:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:34:40 UTC to 2016-06-21 20:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 20:54:40 UTC to 2016-06-21 20:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:14:40 UTC to 2016-06-21 21:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:34:40 UTC to 2016-06-21 21:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 21:54:40 UTC to 2016-06-21 21:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:14:40 UTC to 2016-06-21 22:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:34:40 UTC to 2016-06-21 22:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 22:54:40 UTC to 2016-06-21 22:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:14:40 UTC to 2016-06-21 23:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:34:40 UTC to 2016-06-21 23:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-21 23:54:40 UTC to 2016-06-21 23:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:14:40 UTC to 2016-06-22 00:15:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:34:40 UTC to 2016-06-22 00:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 00:54:40 UTC to 2016-06-22 00:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:14:39 UTC to 2016-06-22 01:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:34:39 UTC to 2016-06-22 01:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 01:54:39 UTC to 2016-06-22 01:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:14:39 UTC to 2016-06-22 02:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:34:40 UTC to 2016-06-22 02:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 02:54:40 UTC to 2016-06-22 02:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:14:39 UTC to 2016-06-22 03:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:34:40 UTC to 2016-06-22 03:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 03:54:40 UTC to 2016-06-22 03:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:14:39 UTC to 2016-06-22 04:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:34:40 UTC to 2016-06-22 04:35:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 04:54:40 UTC to 2016-06-22 04:55:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:14:39 UTC to 2016-06-22 05:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:34:39 UTC to 2016-06-22 05:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 05:54:39 UTC to 2016-06-22 05:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:14:39 UTC to 2016-06-22 06:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:34:39 UTC to 2016-06-22 06:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 06:54:39 UTC to 2016-06-22 06:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:14:39 UTC to 2016-06-22 07:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:34:39 UTC to 2016-06-22 07:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 07:54:39 UTC to 2016-06-22 07:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:14:39 UTC to 2016-06-22 08:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:34:39 UTC to 2016-06-22 08:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 08:54:39 UTC to 2016-06-22 08:54:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 09:14:39 UTC to 2016-06-22 09:14:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-22 09:34:39 UTC to 2016-06-22 09:34:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:20:03 UTC to 2016-06-23 20:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:30:03 UTC to 2016-06-23 20:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 20:50:03 UTC to 2016-06-23 20:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:10:03 UTC to 2016-06-23 21:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:30:03 UTC to 2016-06-23 21:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 21:50:03 UTC to 2016-06-23 21:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:10:03 UTC to 2016-06-23 22:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:30:03 UTC to 2016-06-23 22:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 22:50:03 UTC to 2016-06-23 22:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:10:03 UTC to 2016-06-23 23:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:30:03 UTC to 2016-06-23 23:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-23 23:50:03 UTC to 2016-06-23 23:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:10:03 UTC to 2016-06-24 00:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:30:03 UTC to 2016-06-24 00:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 00:50:03 UTC to 2016-06-24 00:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:10:03 UTC to 2016-06-24 01:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:30:03 UTC to 2016-06-24 01:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 01:50:03 UTC to 2016-06-24 01:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:10:03 UTC to 2016-06-24 02:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:30:03 UTC to 2016-06-24 02:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 02:50:03 UTC to 2016-06-24 02:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:10:03 UTC to 2016-06-24 03:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:30:03 UTC to 2016-06-24 03:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 03:50:03 UTC to 2016-06-24 03:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:10:03 UTC to 2016-06-24 04:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:30:03 UTC to 2016-06-24 04:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 04:50:03 UTC to 2016-06-24 04:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:10:03 UTC to 2016-06-24 05:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:30:03 UTC to 2016-06-24 05:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 05:50:03 UTC to 2016-06-24 05:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:10:03 UTC to 2016-06-24 06:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:30:03 UTC to 2016-06-24 06:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 06:50:03 UTC to 2016-06-24 06:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:10:03 UTC to 2016-06-24 07:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:30:03 UTC to 2016-06-24 07:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 07:50:03 UTC to 2016-06-24 07:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:10:03 UTC to 2016-06-24 08:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:30:03 UTC to 2016-06-24 08:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 08:50:03 UTC to 2016-06-24 08:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:10:03 UTC to 2016-06-24 09:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:30:03 UTC to 2016-06-24 09:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 09:50:03 UTC to 2016-06-24 09:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:10:03 UTC to 2016-06-24 10:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:30:03 UTC to 2016-06-24 10:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 10:50:02 UTC to 2016-06-24 10:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:10:03 UTC to 2016-06-24 11:10:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:30:03 UTC to 2016-06-24 11:30:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 11:50:02 UTC to 2016-06-24 11:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:10:02 UTC to 2016-06-24 12:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:30:02 UTC to 2016-06-24 12:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 12:50:02 UTC to 2016-06-24 12:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:10:02 UTC to 2016-06-24 13:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:30:02 UTC to 2016-06-24 13:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 13:50:02 UTC to 2016-06-24 13:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:10:02 UTC to 2016-06-24 14:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:30:02 UTC to 2016-06-24 14:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 14:50:02 UTC to 2016-06-24 14:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:10:02 UTC to 2016-06-24 15:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:30:02 UTC to 2016-06-24 15:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 15:50:02 UTC to 2016-06-24 15:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:10:02 UTC to 2016-06-24 16:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:30:02 UTC to 2016-06-24 16:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 16:50:02 UTC to 2016-06-24 16:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:10:02 UTC to 2016-06-24 17:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:30:02 UTC to 2016-06-24 17:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 17:50:02 UTC to 2016-06-24 17:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:10:02 UTC to 2016-06-24 18:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:30:02 UTC to 2016-06-24 18:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 18:50:02 UTC to 2016-06-24 18:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:10:02 UTC to 2016-06-24 19:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:30:02 UTC to 2016-06-24 19:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 19:50:02 UTC to 2016-06-24 19:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:10:02 UTC to 2016-06-24 20:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:30:02 UTC to 2016-06-24 20:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 20:50:02 UTC to 2016-06-24 20:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:10:02 UTC to 2016-06-24 21:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:30:02 UTC to 2016-06-24 21:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 21:50:02 UTC to 2016-06-24 21:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:10:02 UTC to 2016-06-24 22:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:30:02 UTC to 2016-06-24 22:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 22:50:02 UTC to 2016-06-24 22:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:10:02 UTC to 2016-06-24 23:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:30:02 UTC to 2016-06-24 23:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-24 23:50:02 UTC to 2016-06-24 23:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:10:02 UTC to 2016-06-25 00:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:30:02 UTC to 2016-06-25 00:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 00:50:02 UTC to 2016-06-25 00:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:10:02 UTC to 2016-06-25 01:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:30:02 UTC to 2016-06-25 01:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 01:50:02 UTC to 2016-06-25 01:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:10:02 UTC to 2016-06-25 02:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:30:02 UTC to 2016-06-25 02:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 02:50:02 UTC to 2016-06-25 02:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:10:02 UTC to 2016-06-25 03:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:30:02 UTC to 2016-06-25 03:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 03:50:02 UTC to 2016-06-25 03:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:10:02 UTC to 2016-06-25 04:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:30:02 UTC to 2016-06-25 04:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 04:50:02 UTC to 2016-06-25 04:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:10:02 UTC to 2016-06-25 05:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:30:02 UTC to 2016-06-25 05:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 05:50:02 UTC to 2016-06-25 05:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:10:02 UTC to 2016-06-25 06:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:30:02 UTC to 2016-06-25 06:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 06:50:02 UTC to 2016-06-25 06:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:10:02 UTC to 2016-06-25 07:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:30:02 UTC to 2016-06-25 07:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 07:50:02 UTC to 2016-06-25 07:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:10:02 UTC to 2016-06-25 08:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:30:02 UTC to 2016-06-25 08:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 08:50:02 UTC to 2016-06-25 08:50:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 09:10:02 UTC to 2016-06-25 09:10:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-25 09:30:02 UTC to 2016-06-25 09:30:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 14:24:30 UTC to 2016-06-26 14:24:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 15:04:30 UTC to 2016-06-26 15:04:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 15:44:30 UTC to 2016-06-26 15:44:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:04:29 UTC to 2016-06-26 16:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:24:30 UTC to 2016-06-26 16:24:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 16:44:29 UTC to 2016-06-26 16:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:04:29 UTC to 2016-06-26 17:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:24:29 UTC to 2016-06-26 17:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 17:44:29 UTC to 2016-06-26 17:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:04:29 UTC to 2016-06-26 18:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:24:29 UTC to 2016-06-26 18:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 18:44:29 UTC to 2016-06-26 18:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:04:29 UTC to 2016-06-26 19:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:24:29 UTC to 2016-06-26 19:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 19:44:29 UTC to 2016-06-26 19:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:04:29 UTC to 2016-06-26 20:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:24:29 UTC to 2016-06-26 20:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 20:44:29 UTC to 2016-06-26 20:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:04:29 UTC to 2016-06-26 21:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:24:29 UTC to 2016-06-26 21:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 21:44:29 UTC to 2016-06-26 21:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:04:29 UTC to 2016-06-26 22:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:24:29 UTC to 2016-06-26 22:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 22:44:29 UTC to 2016-06-26 22:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 23:04:29 UTC to 2016-06-26 23:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-26 23:24:29 UTC to 2016-06-26 23:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:04:29 UTC to 2016-06-27 00:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:24:29 UTC to 2016-06-27 00:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 00:44:29 UTC to 2016-06-27 00:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:04:29 UTC to 2016-06-27 01:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:24:29 UTC to 2016-06-27 01:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 01:44:29 UTC to 2016-06-27 01:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:04:29 UTC to 2016-06-27 02:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:24:29 UTC to 2016-06-27 02:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 02:44:29 UTC to 2016-06-27 02:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:04:29 UTC to 2016-06-27 03:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:24:29 UTC to 2016-06-27 03:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 03:44:29 UTC to 2016-06-27 03:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:04:29 UTC to 2016-06-27 04:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:24:29 UTC to 2016-06-27 04:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 04:44:29 UTC to 2016-06-27 04:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:04:29 UTC to 2016-06-27 05:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:24:29 UTC to 2016-06-27 05:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 05:44:29 UTC to 2016-06-27 05:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:04:29 UTC to 2016-06-27 06:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:24:29 UTC to 2016-06-27 06:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 06:44:29 UTC to 2016-06-27 06:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:04:29 UTC to 2016-06-27 07:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:24:29 UTC to 2016-06-27 07:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 07:44:29 UTC to 2016-06-27 07:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:04:29 UTC to 2016-06-27 08:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:24:29 UTC to 2016-06-27 08:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 08:44:29 UTC to 2016-06-27 08:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:04:29 UTC to 2016-06-27 09:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:24:29 UTC to 2016-06-27 09:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 09:44:29 UTC to 2016-06-27 09:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:04:29 UTC to 2016-06-27 10:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:24:29 UTC to 2016-06-27 10:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 10:44:29 UTC to 2016-06-27 10:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:04:29 UTC to 2016-06-27 11:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:24:29 UTC to 2016-06-27 11:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 11:44:29 UTC to 2016-06-27 11:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:04:29 UTC to 2016-06-27 12:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:24:29 UTC to 2016-06-27 12:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 12:44:29 UTC to 2016-06-27 12:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:04:29 UTC to 2016-06-27 13:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:24:29 UTC to 2016-06-27 13:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 13:44:29 UTC to 2016-06-27 13:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:04:29 UTC to 2016-06-27 14:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:24:29 UTC to 2016-06-27 14:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 14:44:29 UTC to 2016-06-27 14:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:04:29 UTC to 2016-06-27 15:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:24:29 UTC to 2016-06-27 15:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 15:44:29 UTC to 2016-06-27 15:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:04:29 UTC to 2016-06-27 16:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:24:29 UTC to 2016-06-27 16:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 16:44:29 UTC to 2016-06-27 16:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:04:29 UTC to 2016-06-27 17:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:24:29 UTC to 2016-06-27 17:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 17:44:29 UTC to 2016-06-27 17:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:04:29 UTC to 2016-06-27 18:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:24:29 UTC to 2016-06-27 18:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 18:44:29 UTC to 2016-06-27 18:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:04:29 UTC to 2016-06-27 19:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:24:29 UTC to 2016-06-27 19:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 19:44:29 UTC to 2016-06-27 19:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:04:28 UTC to 2016-06-27 20:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:24:29 UTC to 2016-06-27 20:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 20:44:28 UTC to 2016-06-27 20:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:04:29 UTC to 2016-06-27 21:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:24:29 UTC to 2016-06-27 21:24:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 21:44:29 UTC to 2016-06-27 21:44:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:04:29 UTC to 2016-06-27 22:04:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:24:28 UTC to 2016-06-27 22:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 22:44:28 UTC to 2016-06-27 22:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:04:28 UTC to 2016-06-27 23:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:24:28 UTC to 2016-06-27 23:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-27 23:44:28 UTC to 2016-06-27 23:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:04:28 UTC to 2016-06-28 00:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:24:28 UTC to 2016-06-28 00:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 00:44:28 UTC to 2016-06-28 00:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:04:28 UTC to 2016-06-28 01:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:24:28 UTC to 2016-06-28 01:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 01:44:28 UTC to 2016-06-28 01:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:04:28 UTC to 2016-06-28 02:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:24:28 UTC to 2016-06-28 02:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 02:44:28 UTC to 2016-06-28 02:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:04:28 UTC to 2016-06-28 03:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:24:28 UTC to 2016-06-28 03:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 03:44:28 UTC to 2016-06-28 03:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:04:28 UTC to 2016-06-28 04:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:24:28 UTC to 2016-06-28 04:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 04:44:28 UTC to 2016-06-28 04:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:04:28 UTC to 2016-06-28 05:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:24:28 UTC to 2016-06-28 05:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 05:44:28 UTC to 2016-06-28 05:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:04:28 UTC to 2016-06-28 06:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:24:28 UTC to 2016-06-28 06:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 06:44:28 UTC to 2016-06-28 06:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:04:28 UTC to 2016-06-28 07:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:24:28 UTC to 2016-06-28 07:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 07:44:28 UTC to 2016-06-28 07:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:04:28 UTC to 2016-06-28 08:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:24:28 UTC to 2016-06-28 08:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 08:44:28 UTC to 2016-06-28 08:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:04:28 UTC to 2016-06-28 09:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:24:28 UTC to 2016-06-28 09:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 09:44:28 UTC to 2016-06-28 09:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:04:28 UTC to 2016-06-28 10:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:24:28 UTC to 2016-06-28 10:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 10:44:28 UTC to 2016-06-28 10:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:04:28 UTC to 2016-06-28 11:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:24:28 UTC to 2016-06-28 11:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 11:44:28 UTC to 2016-06-28 11:44:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 12:04:28 UTC to 2016-06-28 12:04:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-28 12:24:28 UTC to 2016-06-28 12:24:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:21:41 UTC to 2016-06-30 20:22:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:31:41 UTC to 2016-06-30 20:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 20:51:41 UTC to 2016-06-30 20:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:11:41 UTC to 2016-06-30 21:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:31:41 UTC to 2016-06-30 21:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 21:51:41 UTC to 2016-06-30 21:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:11:41 UTC to 2016-06-30 22:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:31:41 UTC to 2016-06-30 22:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 22:51:41 UTC to 2016-06-30 22:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:11:41 UTC to 2016-06-30 23:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:31:41 UTC to 2016-06-30 23:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-06-30 23:51:41 UTC to 2016-06-30 23:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:11:41 UTC to 2016-07-01 00:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:31:41 UTC to 2016-07-01 00:32:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 00:51:41 UTC to 2016-07-01 00:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:11:41 UTC to 2016-07-01 01:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:31:40 UTC to 2016-07-01 01:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 01:51:41 UTC to 2016-07-01 01:52:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:11:40 UTC to 2016-07-01 02:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:31:40 UTC to 2016-07-01 02:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 02:51:40 UTC to 2016-07-01 02:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:11:41 UTC to 2016-07-01 03:12:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:31:40 UTC to 2016-07-01 03:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 03:51:40 UTC to 2016-07-01 03:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:11:40 UTC to 2016-07-01 04:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:31:40 UTC to 2016-07-01 04:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 04:51:40 UTC to 2016-07-01 04:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:11:40 UTC to 2016-07-01 05:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:31:40 UTC to 2016-07-01 05:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 05:51:40 UTC to 2016-07-01 05:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:11:40 UTC to 2016-07-01 06:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:31:40 UTC to 2016-07-01 06:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 06:51:40 UTC to 2016-07-01 06:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:11:40 UTC to 2016-07-01 07:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:31:40 UTC to 2016-07-01 07:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 07:51:40 UTC to 2016-07-01 07:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-01 08:11:40 UTC to 2016-07-01 08:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 08:31:40 UTC to 2016-07-01 08:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 08:51:40 UTC to 2016-07-01 08:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:11:40 UTC to 2016-07-01 09:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:31:40 UTC to 2016-07-01 09:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:51:40 UTC to 2016-07-01 09:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:11:40 UTC to 2016-07-01 10:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:31:40 UTC to 2016-07-01 10:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:51:40 UTC to 2016-07-01 10:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:11:40 UTC to 2016-07-01 11:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:31:40 UTC to 2016-07-01 11:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:51:40 UTC to 2016-07-01 11:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:11:40 UTC to 2016-07-01 12:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:31:50 UTC to 2016-07-01 12:32:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:51:40 UTC to 2016-07-01 12:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:11:40 UTC to 2016-07-01 13:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:31:40 UTC to 2016-07-01 13:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:51:40 UTC to 2016-07-01 13:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:11:40 UTC to 2016-07-01 14:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:31:40 UTC to 2016-07-01 14:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:51:40 UTC to 2016-07-01 14:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:11:40 UTC to 2016-07-01 15:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:31:40 UTC to 2016-07-01 15:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:51:40 UTC to 2016-07-01 15:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:11:40 UTC to 2016-07-01 16:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:31:40 UTC to 2016-07-01 16:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:51:40 UTC to 2016-07-01 16:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:11:40 UTC to 2016-07-01 17:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:31:40 UTC to 2016-07-01 17:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:51:40 UTC to 2016-07-01 17:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:11:40 UTC to 2016-07-01 18:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:31:40 UTC to 2016-07-01 18:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:51:40 UTC to 2016-07-01 18:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:11:40 UTC to 2016-07-01 19:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:31:40 UTC to 2016-07-01 19:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:51:40 UTC to 2016-07-01 19:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:11:40 UTC to 2016-07-01 20:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:31:40 UTC to 2016-07-01 20:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:51:40 UTC to 2016-07-01 20:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:11:40 UTC to 2016-07-01 21:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:31:40 UTC to 2016-07-01 21:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:51:40 UTC to 2016-07-01 21:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:11:40 UTC to 2016-07-01 22:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:31:40 UTC to 2016-07-01 22:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:51:40 UTC to 2016-07-01 22:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:11:40 UTC to 2016-07-01 23:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:31:40 UTC to 2016-07-01 23:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:51:40 UTC to 2016-07-01 23:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:11:40 UTC to 2016-07-02 00:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:31:40 UTC to 2016-07-02 00:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:51:40 UTC to 2016-07-02 00:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:11:40 UTC to 2016-07-02 01:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:31:40 UTC to 2016-07-02 01:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:51:40 UTC to 2016-07-02 01:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:11:40 UTC to 2016-07-02 02:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:31:40 UTC to 2016-07-02 02:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:51:40 UTC to 2016-07-02 02:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:11:40 UTC to 2016-07-02 03:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:31:40 UTC to 2016-07-02 03:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:51:40 UTC to 2016-07-02 03:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:11:39 UTC to 2016-07-02 04:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:31:40 UTC to 2016-07-02 04:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:51:39 UTC to 2016-07-02 04:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:11:39 UTC to 2016-07-02 05:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:31:39 UTC to 2016-07-02 05:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:51:39 UTC to 2016-07-02 05:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:11:39 UTC to 2016-07-02 06:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:31:39 UTC to 2016-07-02 06:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:51:39 UTC to 2016-07-02 06:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:11:39 UTC to 2016-07-02 07:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:31:39 UTC to 2016-07-02 07:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:51:39 UTC to 2016-07-02 07:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:11:39 UTC to 2016-07-02 08:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:31:39 UTC to 2016-07-02 08:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:51:39 UTC to 2016-07-02 08:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:11:39 UTC to 2016-07-02 09:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:31:39 UTC to 2016-07-02 09:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:51:39 UTC to 2016-07-02 09:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:11:39 UTC to 2016-07-02 10:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:31:39 UTC to 2016-07-02 10:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:51:39 UTC to 2016-07-02 10:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:11:39 UTC to 2016-07-02 11:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:31:39 UTC to 2016-07-02 11:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:51:39 UTC to 2016-07-02 11:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:11:39 UTC to 2016-07-02 12:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:31:39 UTC to 2016-07-02 12:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:51:39 UTC to 2016-07-02 12:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:11:39 UTC to 2016-07-02 13:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:31:39 UTC to 2016-07-02 13:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:51:39 UTC to 2016-07-02 13:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:11:39 UTC to 2016-07-02 14:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:31:39 UTC to 2016-07-02 14:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:51:39 UTC to 2016-07-02 14:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:11:39 UTC to 2016-07-02 15:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:31:39 UTC to 2016-07-02 15:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:51:39 UTC to 2016-07-02 15:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:11:39 UTC to 2016-07-02 16:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:31:39 UTC to 2016-07-02 16:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:51:39 UTC to 2016-07-02 16:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:11:39 UTC to 2016-07-02 17:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:31:39 UTC to 2016-07-02 17:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:51:39 UTC to 2016-07-02 17:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:11:39 UTC to 2016-07-02 18:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:31:39 UTC to 2016-07-02 18:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:51:39 UTC to 2016-07-02 18:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:11:39 UTC to 2016-07-02 19:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:31:39 UTC to 2016-07-02 19:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:51:39 UTC to 2016-07-02 19:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:11:39 UTC to 2016-07-02 20:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:31:39 UTC to 2016-07-02 20:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:51:39 UTC to 2016-07-02 20:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:11:39 UTC to 2016-07-02 21:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:31:39 UTC to 2016-07-02 21:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:51:39 UTC to 2016-07-02 21:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:11:39 UTC to 2016-07-02 22:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:31:39 UTC to 2016-07-02 22:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:51:39 UTC to 2016-07-02 22:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:11:39 UTC to 2016-07-02 23:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:31:39 UTC to 2016-07-02 23:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:51:39 UTC to 2016-07-02 23:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:11:39 UTC to 2016-07-03 00:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:31:39 UTC to 2016-07-03 00:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:51:39 UTC to 2016-07-03 00:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:11:39 UTC to 2016-07-03 01:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:31:39 UTC to 2016-07-03 01:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:51:39 UTC to 2016-07-03 01:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:11:39 UTC to 2016-07-03 02:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:31:39 UTC to 2016-07-03 02:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:51:39 UTC to 2016-07-03 02:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:11:39 UTC to 2016-07-03 03:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:31:39 UTC to 2016-07-03 03:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:51:39 UTC to 2016-07-03 03:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:11:39 UTC to 2016-07-03 04:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:31:39 UTC to 2016-07-03 04:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:51:39 UTC to 2016-07-03 04:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:11:39 UTC to 2016-07-03 05:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:31:39 UTC to 2016-07-03 05:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:51:39 UTC to 2016-07-03 05:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:11:39 UTC to 2016-07-03 06:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:31:39 UTC to 2016-07-03 06:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:51:39 UTC to 2016-07-03 06:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:11:39 UTC to 2016-07-03 07:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:31:39 UTC to 2016-07-03 07:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:51:39 UTC to 2016-07-03 07:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:11:39 UTC to 2016-07-03 08:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:31:38 UTC to 2016-07-03 08:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:51:38 UTC to 2016-07-03 08:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:11:38 UTC to 2016-07-03 09:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:31:38 UTC to 2016-07-03 09:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:51:38 UTC to 2016-07-03 09:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:11:38 UTC to 2016-07-03 10:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:31:38 UTC to 2016-07-03 10:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:51:38 UTC to 2016-07-03 10:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:11:38 UTC to 2016-07-03 11:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:31:38 UTC to 2016-07-03 11:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:51:38 UTC to 2016-07-03 11:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:11:38 UTC to 2016-07-03 12:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:31:38 UTC to 2016-07-03 12:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:51:38 UTC to 2016-07-03 12:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:11:38 UTC to 2016-07-03 13:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:31:38 UTC to 2016-07-03 13:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:51:38 UTC to 2016-07-03 13:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:11:38 UTC to 2016-07-03 14:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:31:38 UTC to 2016-07-03 14:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:51:38 UTC to 2016-07-03 14:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:11:38 UTC to 2016-07-03 15:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:31:38 UTC to 2016-07-03 15:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:51:38 UTC to 2016-07-03 15:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:11:38 UTC to 2016-07-03 16:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:31:38 UTC to 2016-07-03 16:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:51:38 UTC to 2016-07-03 16:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:11:38 UTC to 2016-07-03 17:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:31:38 UTC to 2016-07-03 17:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:51:38 UTC to 2016-07-03 17:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:11:38 UTC to 2016-07-03 18:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:31:38 UTC to 2016-07-03 18:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:51:38 UTC to 2016-07-03 18:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:11:38 UTC to 2016-07-03 19:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:31:38 UTC to 2016-07-03 19:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:51:38 UTC to 2016-07-03 19:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:11:38 UTC to 2016-07-03 20:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:31:38 UTC to 2016-07-03 20:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:51:38 UTC to 2016-07-03 20:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:11:38 UTC to 2016-07-03 21:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:31:38 UTC to 2016-07-03 21:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:51:38 UTC to 2016-07-03 21:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:11:38 UTC to 2016-07-03 22:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:31:38 UTC to 2016-07-03 22:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:51:38 UTC to 2016-07-03 22:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:11:38 UTC to 2016-07-03 23:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:31:38 UTC to 2016-07-03 23:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:51:38 UTC to 2016-07-03 23:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:11:38 UTC to 2016-07-04 00:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:31:38 UTC to 2016-07-04 00:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:51:38 UTC to 2016-07-04 00:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:11:38 UTC to 2016-07-04 01:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:31:38 UTC to 2016-07-04 01:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:51:38 UTC to 2016-07-04 01:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:11:38 UTC to 2016-07-04 02:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:31:38 UTC to 2016-07-04 02:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:51:38 UTC to 2016-07-04 02:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:11:38 UTC to 2016-07-04 03:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:31:38 UTC to 2016-07-04 03:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:51:38 UTC to 2016-07-04 03:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:11:38 UTC to 2016-07-04 04:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:31:38 UTC to 2016-07-04 04:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:51:38 UTC to 2016-07-04 04:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:11:38 UTC to 2016-07-04 05:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:31:38 UTC to 2016-07-04 05:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:51:38 UTC to 2016-07-04 05:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:11:38 UTC to 2016-07-04 06:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:31:38 UTC to 2016-07-04 06:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:51:38 UTC to 2016-07-04 06:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:11:38 UTC to 2016-07-04 07:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:31:38 UTC to 2016-07-04 07:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:51:38 UTC to 2016-07-04 07:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:11:38 UTC to 2016-07-04 08:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:31:38 UTC to 2016-07-04 08:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:51:38 UTC to 2016-07-04 08:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:18:19 UTC to 2016-07-05 02:18:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:28:18 UTC to 2016-07-05 02:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:48:18 UTC to 2016-07-05 02:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:08:18 UTC to 2016-07-05 03:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:28:18 UTC to 2016-07-05 03:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:48:18 UTC to 2016-07-05 03:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:08:18 UTC to 2016-07-05 04:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:28:18 UTC to 2016-07-05 04:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:48:18 UTC to 2016-07-05 04:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:08:18 UTC to 2016-07-05 05:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:28:18 UTC to 2016-07-05 05:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:48:18 UTC to 2016-07-05 05:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:08:18 UTC to 2016-07-05 06:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:28:18 UTC to 2016-07-05 06:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:48:18 UTC to 2016-07-05 06:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:08:18 UTC to 2016-07-05 07:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:28:18 UTC to 2016-07-05 07:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:48:18 UTC to 2016-07-05 07:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:08:18 UTC to 2016-07-05 08:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:28:18 UTC to 2016-07-05 08:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:48:18 UTC to 2016-07-05 08:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:08:18 UTC to 2016-07-05 09:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:28:18 UTC to 2016-07-05 09:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:48:18 UTC to 2016-07-05 09:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:08:18 UTC to 2016-07-05 10:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:28:18 UTC to 2016-07-05 10:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:48:18 UTC to 2016-07-05 10:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:08:18 UTC to 2016-07-05 11:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:28:18 UTC to 2016-07-05 11:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:48:18 UTC to 2016-07-05 11:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:08:18 UTC to 2016-07-05 12:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:28:18 UTC to 2016-07-05 12:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:48:18 UTC to 2016-07-05 12:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:08:18 UTC to 2016-07-05 13:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:28:18 UTC to 2016-07-05 13:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:48:18 UTC to 2016-07-05 13:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:08:18 UTC to 2016-07-05 14:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:28:18 UTC to 2016-07-05 14:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:48:18 UTC to 2016-07-05 14:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:08:18 UTC to 2016-07-05 15:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:28:18 UTC to 2016-07-05 15:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:48:18 UTC to 2016-07-05 15:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:08:18 UTC to 2016-07-05 16:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:28:18 UTC to 2016-07-05 16:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:48:18 UTC to 2016-07-05 16:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:08:18 UTC to 2016-07-05 17:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:28:18 UTC to 2016-07-05 17:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:48:18 UTC to 2016-07-05 17:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:08:18 UTC to 2016-07-05 18:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:28:18 UTC to 2016-07-05 18:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:48:18 UTC to 2016-07-05 18:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:08:18 UTC to 2016-07-05 19:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:28:18 UTC to 2016-07-05 19:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:48:18 UTC to 2016-07-05 19:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:08:18 UTC to 2016-07-05 20:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:28:18 UTC to 2016-07-05 20:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:48:18 UTC to 2016-07-05 20:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:08:18 UTC to 2016-07-05 21:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:28:18 UTC to 2016-07-05 21:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:48:18 UTC to 2016-07-05 21:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:08:18 UTC to 2016-07-05 22:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:28:18 UTC to 2016-07-05 22:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:48:18 UTC to 2016-07-05 22:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:08:18 UTC to 2016-07-05 23:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:28:18 UTC to 2016-07-05 23:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:48:17 UTC to 2016-07-05 23:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:08:18 UTC to 2016-07-06 00:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:28:18 UTC to 2016-07-06 00:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:48:18 UTC to 2016-07-06 00:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:08:18 UTC to 2016-07-06 01:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:28:17 UTC to 2016-07-06 01:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:48:17 UTC to 2016-07-06 01:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:08:18 UTC to 2016-07-06 02:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:28:17 UTC to 2016-07-06 02:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:48:17 UTC to 2016-07-06 02:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:08:17 UTC to 2016-07-06 03:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:28:17 UTC to 2016-07-06 03:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:48:17 UTC to 2016-07-06 03:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:08:17 UTC to 2016-07-06 04:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:28:17 UTC to 2016-07-06 04:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:48:17 UTC to 2016-07-06 04:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:08:17 UTC to 2016-07-06 05:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:28:17 UTC to 2016-07-06 05:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:48:17 UTC to 2016-07-06 05:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:08:17 UTC to 2016-07-06 06:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:28:17 UTC to 2016-07-06 06:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:48:17 UTC to 2016-07-06 06:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:08:17 UTC to 2016-07-06 07:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:28:17 UTC to 2016-07-06 07:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:48:17 UTC to 2016-07-06 07:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:08:17 UTC to 2016-07-06 08:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:28:17 UTC to 2016-07-06 08:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:48:17 UTC to 2016-07-06 08:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:08:17 UTC to 2016-07-06 09:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:28:17 UTC to 2016-07-06 09:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:48:17 UTC to 2016-07-06 09:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:08:17 UTC to 2016-07-06 10:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:28:17 UTC to 2016-07-06 10:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:48:17 UTC to 2016-07-06 10:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:08:17 UTC to 2016-07-06 11:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:28:17 UTC to 2016-07-06 11:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:48:17 UTC to 2016-07-06 11:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:08:17 UTC to 2016-07-06 12:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:28:17 UTC to 2016-07-06 12:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:48:17 UTC to 2016-07-06 12:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:08:17 UTC to 2016-07-06 13:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:28:17 UTC to 2016-07-06 13:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:48:17 UTC to 2016-07-06 13:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:08:17 UTC to 2016-07-06 14:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:28:17 UTC to 2016-07-06 14:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:48:17 UTC to 2016-07-06 14:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 15:28:17 UTC to 2016-07-06 15:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 15:48:17 UTC to 2016-07-06 15:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:08:17 UTC to 2016-07-06 16:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:28:17 UTC to 2016-07-06 16:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:48:17 UTC to 2016-07-06 16:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:08:17 UTC to 2016-07-06 17:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:28:17 UTC to 2016-07-06 17:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:48:17 UTC to 2016-07-06 17:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:08:17 UTC to 2016-07-06 18:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:28:17 UTC to 2016-07-06 18:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:48:17 UTC to 2016-07-06 18:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:08:17 UTC to 2016-07-06 19:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:28:17 UTC to 2016-07-06 19:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:48:17 UTC to 2016-07-06 19:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:08:17 UTC to 2016-07-06 20:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:28:17 UTC to 2016-07-06 20:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:48:17 UTC to 2016-07-06 20:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 21:08:17 UTC to 2016-07-06 21:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:02:35 UTC to 2016-07-09 00:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:12:35 UTC to 2016-07-09 00:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:32:35 UTC to 2016-07-09 00:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:52:35 UTC to 2016-07-09 00:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:12:35 UTC to 2016-07-09 01:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:32:35 UTC to 2016-07-09 01:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:52:35 UTC to 2016-07-09 01:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 02:32:35 UTC to 2016-07-09 02:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 02:52:35 UTC to 2016-07-09 02:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:12:35 UTC to 2016-07-09 03:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:32:35 UTC to 2016-07-09 03:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:52:35 UTC to 2016-07-09 03:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:12:35 UTC to 2016-07-09 04:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:32:35 UTC to 2016-07-09 04:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:52:35 UTC to 2016-07-09 04:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:12:35 UTC to 2016-07-09 05:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:32:34 UTC to 2016-07-09 05:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:52:35 UTC to 2016-07-09 05:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:12:35 UTC to 2016-07-09 06:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:32:34 UTC to 2016-07-09 06:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:52:34 UTC to 2016-07-09 06:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:12:34 UTC to 2016-07-09 07:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:32:34 UTC to 2016-07-09 07:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:52:34 UTC to 2016-07-09 07:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:12:34 UTC to 2016-07-09 08:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:32:34 UTC to 2016-07-09 08:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:52:34 UTC to 2016-07-09 08:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:12:34 UTC to 2016-07-09 09:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:32:34 UTC to 2016-07-09 09:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:52:34 UTC to 2016-07-09 09:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:12:34 UTC to 2016-07-09 10:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:32:34 UTC to 2016-07-09 10:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:52:34 UTC to 2016-07-09 10:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:12:34 UTC to 2016-07-09 11:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:32:34 UTC to 2016-07-09 11:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:52:34 UTC to 2016-07-09 11:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:12:34 UTC to 2016-07-09 12:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:32:34 UTC to 2016-07-09 12:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:52:34 UTC to 2016-07-09 12:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:12:34 UTC to 2016-07-09 13:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:32:34 UTC to 2016-07-09 13:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:52:34 UTC to 2016-07-09 13:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:12:34 UTC to 2016-07-09 14:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:32:34 UTC to 2016-07-09 14:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:52:34 UTC to 2016-07-09 14:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:12:34 UTC to 2016-07-09 15:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:32:34 UTC to 2016-07-09 15:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:52:34 UTC to 2016-07-09 15:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:12:34 UTC to 2016-07-09 16:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:32:34 UTC to 2016-07-09 16:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:52:34 UTC to 2016-07-09 16:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:12:34 UTC to 2016-07-09 17:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:32:34 UTC to 2016-07-09 17:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:52:34 UTC to 2016-07-09 17:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:12:34 UTC to 2016-07-09 18:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:32:34 UTC to 2016-07-09 18:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:52:34 UTC to 2016-07-09 18:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:12:34 UTC to 2016-07-09 19:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:32:34 UTC to 2016-07-09 19:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:52:34 UTC to 2016-07-09 19:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:12:34 UTC to 2016-07-09 20:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:32:34 UTC to 2016-07-09 20:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:52:34 UTC to 2016-07-09 20:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:12:34 UTC to 2016-07-09 21:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:32:34 UTC to 2016-07-09 21:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:52:34 UTC to 2016-07-09 21:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:12:34 UTC to 2016-07-09 22:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:32:34 UTC to 2016-07-09 22:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:52:34 UTC to 2016-07-09 22:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 23:12:34 UTC to 2016-07-09 23:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 23:32:34 UTC to 2016-07-09 23:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 01:53:30 UTC to 2016-07-11 01:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:13:30 UTC to 2016-07-11 02:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:33:30 UTC to 2016-07-11 02:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:53:30 UTC to 2016-07-11 02:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:13:30 UTC to 2016-07-11 03:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:33:30 UTC to 2016-07-11 03:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:53:30 UTC to 2016-07-11 03:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:13:30 UTC to 2016-07-11 04:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:33:30 UTC to 2016-07-11 04:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:53:30 UTC to 2016-07-11 04:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:13:30 UTC to 2016-07-11 05:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:33:30 UTC to 2016-07-11 05:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:53:30 UTC to 2016-07-11 05:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:13:30 UTC to 2016-07-11 06:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:33:30 UTC to 2016-07-11 06:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:53:30 UTC to 2016-07-11 06:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:13:30 UTC to 2016-07-11 07:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:33:30 UTC to 2016-07-11 07:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:53:30 UTC to 2016-07-11 07:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:13:29 UTC to 2016-07-11 08:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:33:30 UTC to 2016-07-11 08:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:53:30 UTC to 2016-07-11 08:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:13:30 UTC to 2016-07-11 09:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:33:29 UTC to 2016-07-11 09:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:53:29 UTC to 2016-07-11 09:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:13:30 UTC to 2016-07-11 10:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:33:29 UTC to 2016-07-11 10:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:53:30 UTC to 2016-07-11 10:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:13:29 UTC to 2016-07-11 11:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:33:29 UTC to 2016-07-11 11:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:53:29 UTC to 2016-07-11 11:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:13:29 UTC to 2016-07-11 12:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:33:29 UTC to 2016-07-11 12:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:53:29 UTC to 2016-07-11 12:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:13:29 UTC to 2016-07-11 13:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:33:29 UTC to 2016-07-11 13:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:53:29 UTC to 2016-07-11 13:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:13:29 UTC to 2016-07-11 14:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:33:29 UTC to 2016-07-11 14:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:53:29 UTC to 2016-07-11 14:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:13:29 UTC to 2016-07-11 15:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:33:29 UTC to 2016-07-11 15:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:53:30 UTC to 2016-07-11 15:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:13:30 UTC to 2016-07-11 16:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:33:29 UTC to 2016-07-11 16:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:53:29 UTC to 2016-07-11 16:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:13:29 UTC to 2016-07-11 17:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:33:29 UTC to 2016-07-11 17:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:53:29 UTC to 2016-07-11 17:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:13:29 UTC to 2016-07-11 18:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:33:29 UTC to 2016-07-11 18:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:53:29 UTC to 2016-07-11 18:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:13:29 UTC to 2016-07-11 19:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:33:30 UTC to 2016-07-11 19:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:53:29 UTC to 2016-07-11 19:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:13:29 UTC to 2016-07-11 20:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:33:29 UTC to 2016-07-11 20:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:53:29 UTC to 2016-07-11 20:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:13:29 UTC to 2016-07-11 21:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:33:29 UTC to 2016-07-11 21:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:53:29 UTC to 2016-07-11 21:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:13:29 UTC to 2016-07-11 22:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:33:29 UTC to 2016-07-11 22:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:53:29 UTC to 2016-07-11 22:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:13:29 UTC to 2016-07-11 23:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:33:29 UTC to 2016-07-11 23:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:53:29 UTC to 2016-07-11 23:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:13:29 UTC to 2016-07-12 00:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:33:29 UTC to 2016-07-12 00:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:53:29 UTC to 2016-07-12 00:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:13:29 UTC to 2016-07-12 01:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:33:29 UTC to 2016-07-12 01:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:53:29 UTC to 2016-07-12 01:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:13:29 UTC to 2016-07-12 02:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:33:29 UTC to 2016-07-12 02:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:53:29 UTC to 2016-07-12 02:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:13:29 UTC to 2016-07-12 03:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:33:29 UTC to 2016-07-12 03:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:53:29 UTC to 2016-07-12 03:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:13:29 UTC to 2016-07-12 04:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:33:29 UTC to 2016-07-12 04:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:53:29 UTC to 2016-07-12 04:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:13:29 UTC to 2016-07-12 05:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:33:29 UTC to 2016-07-12 05:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:53:29 UTC to 2016-07-12 05:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:13:29 UTC to 2016-07-12 06:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:33:29 UTC to 2016-07-12 06:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:53:29 UTC to 2016-07-12 06:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:13:29 UTC to 2016-07-12 07:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:33:29 UTC to 2016-07-12 07:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:53:29 UTC to 2016-07-12 07:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:13:29 UTC to 2016-07-12 08:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:33:29 UTC to 2016-07-12 08:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:53:29 UTC to 2016-07-12 08:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:13:29 UTC to 2016-07-12 09:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:33:29 UTC to 2016-07-12 09:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:53:29 UTC to 2016-07-12 09:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 10:13:29 UTC to 2016-07-12 10:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:09:27 UTC to 2016-07-13 18:09:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:19:28 UTC to 2016-07-13 18:19:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:39:28 UTC to 2016-07-13 18:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:59:28 UTC to 2016-07-13 18:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:19:27 UTC to 2016-07-13 19:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:39:28 UTC to 2016-07-13 19:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:59:28 UTC to 2016-07-13 19:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:19:27 UTC to 2016-07-13 20:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:39:28 UTC to 2016-07-13 20:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:59:27 UTC to 2016-07-13 20:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:19:27 UTC to 2016-07-13 21:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:39:27 UTC to 2016-07-13 21:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:59:27 UTC to 2016-07-13 21:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:19:27 UTC to 2016-07-13 22:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:39:27 UTC to 2016-07-13 22:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:59:27 UTC to 2016-07-13 22:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:19:27 UTC to 2016-07-13 23:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:39:27 UTC to 2016-07-13 23:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:59:28 UTC to 2016-07-13 23:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 00:19:27 UTC to 2016-07-14 00:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 00:59:27 UTC to 2016-07-14 00:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:19:27 UTC to 2016-07-14 01:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:39:27 UTC to 2016-07-14 01:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:59:27 UTC to 2016-07-14 01:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:19:27 UTC to 2016-07-14 02:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:39:27 UTC to 2016-07-14 02:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:59:27 UTC to 2016-07-14 02:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:19:27 UTC to 2016-07-14 03:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:39:27 UTC to 2016-07-14 03:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:59:27 UTC to 2016-07-14 03:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:19:27 UTC to 2016-07-14 04:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:39:27 UTC to 2016-07-14 04:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:59:27 UTC to 2016-07-14 04:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:19:27 UTC to 2016-07-14 05:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:39:27 UTC to 2016-07-14 05:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:59:27 UTC to 2016-07-14 05:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:19:27 UTC to 2016-07-14 06:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:39:27 UTC to 2016-07-14 06:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:59:27 UTC to 2016-07-14 06:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:19:27 UTC to 2016-07-14 07:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:39:27 UTC to 2016-07-14 07:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:59:27 UTC to 2016-07-14 07:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:19:27 UTC to 2016-07-14 08:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:39:27 UTC to 2016-07-14 08:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:59:27 UTC to 2016-07-14 08:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:19:27 UTC to 2016-07-14 09:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:39:27 UTC to 2016-07-14 09:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:59:27 UTC to 2016-07-14 09:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:19:27 UTC to 2016-07-14 10:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:39:27 UTC to 2016-07-14 10:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:59:27 UTC to 2016-07-14 10:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:19:27 UTC to 2016-07-14 11:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:39:27 UTC to 2016-07-14 11:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:59:27 UTC to 2016-07-14 11:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:19:27 UTC to 2016-07-14 12:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:39:27 UTC to 2016-07-14 12:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:59:27 UTC to 2016-07-14 12:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:19:27 UTC to 2016-07-14 13:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:39:27 UTC to 2016-07-14 13:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:59:27 UTC to 2016-07-14 13:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:19:27 UTC to 2016-07-14 14:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:39:27 UTC to 2016-07-14 14:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:59:27 UTC to 2016-07-14 14:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:19:27 UTC to 2016-07-14 15:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:39:27 UTC to 2016-07-14 15:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:59:27 UTC to 2016-07-14 15:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:19:27 UTC to 2016-07-14 16:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:39:27 UTC to 2016-07-14 16:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:59:27 UTC to 2016-07-14 16:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:19:27 UTC to 2016-07-14 17:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:39:27 UTC to 2016-07-14 17:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:59:27 UTC to 2016-07-14 17:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:19:27 UTC to 2016-07-14 18:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:39:27 UTC to 2016-07-14 18:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:59:27 UTC to 2016-07-14 18:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:19:27 UTC to 2016-07-14 19:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:39:26 UTC to 2016-07-14 19:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:59:27 UTC to 2016-07-14 19:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:19:27 UTC to 2016-07-14 20:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:39:26 UTC to 2016-07-14 20:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:59:27 UTC to 2016-07-14 20:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:19:26 UTC to 2016-07-14 21:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:39:26 UTC to 2016-07-14 21:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:59:26 UTC to 2016-07-14 21:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:19:26 UTC to 2016-07-14 22:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:39:26 UTC to 2016-07-14 22:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:59:27 UTC to 2016-07-14 22:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:19:26 UTC to 2016-07-14 23:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:39:26 UTC to 2016-07-14 23:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:59:26 UTC to 2016-07-14 23:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:19:26 UTC to 2016-07-15 00:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:39:26 UTC to 2016-07-15 00:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:59:27 UTC to 2016-07-15 00:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 01:19:27 UTC to 2016-07-15 01:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 01:59:26 UTC to 2016-07-15 01:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:19:26 UTC to 2016-07-15 02:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:39:26 UTC to 2016-07-15 02:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:59:26 UTC to 2016-07-15 02:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:19:26 UTC to 2016-07-15 03:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:39:26 UTC to 2016-07-15 03:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:59:26 UTC to 2016-07-15 03:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:19:26 UTC to 2016-07-15 04:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:39:26 UTC to 2016-07-15 04:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:59:26 UTC to 2016-07-15 04:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 05:19:26 UTC to 2016-07-15 05:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 05:39:26 UTC to 2016-07-15 05:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:19:26 UTC to 2016-07-15 06:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:39:26 UTC to 2016-07-15 06:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:59:26 UTC to 2016-07-15 06:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:19:26 UTC to 2016-07-15 07:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:39:26 UTC to 2016-07-15 07:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:59:26 UTC to 2016-07-15 07:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:19:26 UTC to 2016-07-15 08:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:39:26 UTC to 2016-07-15 08:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:59:26 UTC to 2016-07-15 08:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:19:26 UTC to 2016-07-15 09:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:39:26 UTC to 2016-07-15 09:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:59:26 UTC to 2016-07-15 09:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:19:26 UTC to 2016-07-15 10:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:39:26 UTC to 2016-07-15 10:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:59:26 UTC to 2016-07-15 10:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:19:26 UTC to 2016-07-15 11:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:39:26 UTC to 2016-07-15 11:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:59:26 UTC to 2016-07-15 11:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 19:39:26 UTC to 2016-07-15 19:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 19:59:26 UTC to 2016-07-15 19:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:19:26 UTC to 2016-07-15 20:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:39:26 UTC to 2016-07-15 20:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:59:26 UTC to 2016-07-15 20:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:19:26 UTC to 2016-07-15 21:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:39:26 UTC to 2016-07-15 21:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:59:26 UTC to 2016-07-15 21:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:19:26 UTC to 2016-07-15 22:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:39:25 UTC to 2016-07-15 22:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:59:25 UTC to 2016-07-15 22:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:19:25 UTC to 2016-07-15 23:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:39:25 UTC to 2016-07-15 23:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:59:25 UTC to 2016-07-15 23:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:19:25 UTC to 2016-07-16 00:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:39:25 UTC to 2016-07-16 00:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:59:25 UTC to 2016-07-16 00:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:19:25 UTC to 2016-07-16 01:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:39:25 UTC to 2016-07-16 01:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:59:25 UTC to 2016-07-16 01:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 02:19:25 UTC to 2016-07-16 02:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 02:39:25 UTC to 2016-07-16 02:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:26:55 UTC to 2016-07-17 16:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:36:55 UTC to 2016-07-17 16:37:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:46:55 UTC to 2016-07-17 16:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:06:55 UTC to 2016-07-17 17:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:26:55 UTC to 2016-07-17 17:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:46:55 UTC to 2016-07-17 17:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:06:55 UTC to 2016-07-17 18:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:26:55 UTC to 2016-07-17 18:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:46:55 UTC to 2016-07-17 18:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:06:55 UTC to 2016-07-17 19:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:26:55 UTC to 2016-07-17 19:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:46:55 UTC to 2016-07-17 19:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:06:55 UTC to 2016-07-17 20:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:26:55 UTC to 2016-07-17 20:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:46:55 UTC to 2016-07-17 20:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:06:55 UTC to 2016-07-17 21:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:26:55 UTC to 2016-07-17 21:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:46:55 UTC to 2016-07-17 21:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:06:55 UTC to 2016-07-17 22:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:26:55 UTC to 2016-07-17 22:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:46:55 UTC to 2016-07-17 22:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:06:55 UTC to 2016-07-17 23:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:26:55 UTC to 2016-07-17 23:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:46:55 UTC to 2016-07-17 23:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:06:55 UTC to 2016-07-18 00:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:26:55 UTC to 2016-07-18 00:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:46:54 UTC to 2016-07-18 00:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:06:55 UTC to 2016-07-18 01:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:26:55 UTC to 2016-07-18 01:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:46:54 UTC to 2016-07-18 01:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:06:54 UTC to 2016-07-18 02:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:26:54 UTC to 2016-07-18 02:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:46:55 UTC to 2016-07-18 02:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:06:54 UTC to 2016-07-18 03:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:26:54 UTC to 2016-07-18 03:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:46:54 UTC to 2016-07-18 03:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:06:54 UTC to 2016-07-18 04:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:26:54 UTC to 2016-07-18 04:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:46:54 UTC to 2016-07-18 04:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:06:54 UTC to 2016-07-18 05:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:26:54 UTC to 2016-07-18 05:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:46:54 UTC to 2016-07-18 05:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:06:54 UTC to 2016-07-18 06:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:26:54 UTC to 2016-07-18 06:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:46:54 UTC to 2016-07-18 06:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:06:54 UTC to 2016-07-18 07:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:26:54 UTC to 2016-07-18 07:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:46:54 UTC to 2016-07-18 07:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:06:54 UTC to 2016-07-18 08:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:26:54 UTC to 2016-07-18 08:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:46:54 UTC to 2016-07-18 08:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:06:54 UTC to 2016-07-18 09:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:26:54 UTC to 2016-07-18 09:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:46:54 UTC to 2016-07-18 09:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:06:54 UTC to 2016-07-18 10:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:26:54 UTC to 2016-07-18 10:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:46:54 UTC to 2016-07-18 10:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:06:54 UTC to 2016-07-18 11:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:26:54 UTC to 2016-07-18 11:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:46:54 UTC to 2016-07-18 11:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:06:54 UTC to 2016-07-18 12:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:26:54 UTC to 2016-07-18 12:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:46:54 UTC to 2016-07-18 12:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:06:54 UTC to 2016-07-18 13:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:26:54 UTC to 2016-07-18 13:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:46:54 UTC to 2016-07-18 13:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:06:54 UTC to 2016-07-18 14:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:26:54 UTC to 2016-07-18 14:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:46:54 UTC to 2016-07-18 14:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:06:54 UTC to 2016-07-18 15:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:26:54 UTC to 2016-07-18 15:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:46:54 UTC to 2016-07-18 15:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:06:54 UTC to 2016-07-18 16:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:26:54 UTC to 2016-07-18 16:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:46:54 UTC to 2016-07-18 16:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:06:54 UTC to 2016-07-18 17:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:26:54 UTC to 2016-07-18 17:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:46:54 UTC to 2016-07-18 17:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:06:54 UTC to 2016-07-18 18:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:26:54 UTC to 2016-07-18 18:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:46:54 UTC to 2016-07-18 18:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:06:54 UTC to 2016-07-18 19:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:26:54 UTC to 2016-07-18 19:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:46:54 UTC to 2016-07-18 19:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:06:54 UTC to 2016-07-18 20:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:26:54 UTC to 2016-07-18 20:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:46:54 UTC to 2016-07-18 20:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:06:54 UTC to 2016-07-18 21:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:26:54 UTC to 2016-07-18 21:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:46:54 UTC to 2016-07-18 21:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:06:54 UTC to 2016-07-18 22:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:26:54 UTC to 2016-07-18 22:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:46:54 UTC to 2016-07-18 22:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:06:54 UTC to 2016-07-18 23:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:26:54 UTC to 2016-07-18 23:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:46:54 UTC to 2016-07-18 23:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:06:54 UTC to 2016-07-19 00:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:26:54 UTC to 2016-07-19 00:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:46:54 UTC to 2016-07-19 00:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:06:54 UTC to 2016-07-19 01:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:26:54 UTC to 2016-07-19 01:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:46:54 UTC to 2016-07-19 01:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:06:54 UTC to 2016-07-19 02:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:26:54 UTC to 2016-07-19 02:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:46:54 UTC to 2016-07-19 02:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:06:54 UTC to 2016-07-19 03:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:26:54 UTC to 2016-07-19 03:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:46:54 UTC to 2016-07-19 03:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:06:54 UTC to 2016-07-19 04:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:26:53 UTC to 2016-07-19 04:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:46:53 UTC to 2016-07-19 04:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:06:53 UTC to 2016-07-19 05:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:26:53 UTC to 2016-07-19 05:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:46:53 UTC to 2016-07-19 05:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:06:53 UTC to 2016-07-19 06:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:26:53 UTC to 2016-07-19 06:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:46:53 UTC to 2016-07-19 06:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:06:53 UTC to 2016-07-19 07:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:26:53 UTC to 2016-07-19 07:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:46:53 UTC to 2016-07-19 07:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 08:06:53 UTC to 2016-07-19 08:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 08:26:53 UTC to 2016-07-19 08:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 23:26:30 UTC to 2016-07-19 23:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 23:46:30 UTC to 2016-07-19 23:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:06:30 UTC to 2016-07-20 00:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:26:30 UTC to 2016-07-20 00:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:46:30 UTC to 2016-07-20 00:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:06:30 UTC to 2016-07-20 01:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:26:30 UTC to 2016-07-20 01:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:46:30 UTC to 2016-07-20 01:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:06:30 UTC to 2016-07-20 02:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:26:30 UTC to 2016-07-20 02:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:46:30 UTC to 2016-07-20 02:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:06:30 UTC to 2016-07-20 03:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:26:30 UTC to 2016-07-20 03:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:46:30 UTC to 2016-07-20 03:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:06:30 UTC to 2016-07-20 04:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:26:30 UTC to 2016-07-20 04:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:46:30 UTC to 2016-07-20 04:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:06:30 UTC to 2016-07-20 05:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:26:30 UTC to 2016-07-20 05:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:46:30 UTC to 2016-07-20 05:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:06:30 UTC to 2016-07-20 06:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:26:30 UTC to 2016-07-20 06:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:46:30 UTC to 2016-07-20 06:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:06:30 UTC to 2016-07-20 07:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:26:30 UTC to 2016-07-20 07:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:46:30 UTC to 2016-07-20 07:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:06:30 UTC to 2016-07-20 08:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:26:30 UTC to 2016-07-20 08:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:46:30 UTC to 2016-07-20 08:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:06:30 UTC to 2016-07-20 09:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:26:30 UTC to 2016-07-20 09:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:46:30 UTC to 2016-07-20 09:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:06:30 UTC to 2016-07-20 10:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:26:29 UTC to 2016-07-20 10:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:46:30 UTC to 2016-07-20 10:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:06:30 UTC to 2016-07-20 11:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:26:29 UTC to 2016-07-20 11:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:46:29 UTC to 2016-07-20 11:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:06:30 UTC to 2016-07-20 12:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:26:29 UTC to 2016-07-20 12:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:46:29 UTC to 2016-07-20 12:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:06:29 UTC to 2016-07-20 13:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:26:29 UTC to 2016-07-20 13:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:46:29 UTC to 2016-07-20 13:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:06:29 UTC to 2016-07-20 14:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:26:29 UTC to 2016-07-20 14:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:46:29 UTC to 2016-07-20 14:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:06:29 UTC to 2016-07-20 15:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:26:29 UTC to 2016-07-20 15:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:46:29 UTC to 2016-07-20 15:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:06:29 UTC to 2016-07-20 16:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:26:29 UTC to 2016-07-20 16:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:46:29 UTC to 2016-07-20 16:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:06:29 UTC to 2016-07-20 17:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:26:29 UTC to 2016-07-20 17:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:46:29 UTC to 2016-07-20 17:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:06:29 UTC to 2016-07-20 18:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:26:29 UTC to 2016-07-20 18:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:46:29 UTC to 2016-07-20 18:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:06:29 UTC to 2016-07-20 19:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:26:29 UTC to 2016-07-20 19:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:46:29 UTC to 2016-07-20 19:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:06:29 UTC to 2016-07-20 20:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:26:29 UTC to 2016-07-20 20:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:46:29 UTC to 2016-07-20 20:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:06:29 UTC to 2016-07-20 21:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:26:29 UTC to 2016-07-20 21:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:46:29 UTC to 2016-07-20 21:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:06:29 UTC to 2016-07-20 22:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:26:29 UTC to 2016-07-20 22:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:46:29 UTC to 2016-07-20 22:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:06:29 UTC to 2016-07-20 23:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:26:29 UTC to 2016-07-20 23:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:46:29 UTC to 2016-07-20 23:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:06:29 UTC to 2016-07-21 00:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:26:29 UTC to 2016-07-21 00:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:46:29 UTC to 2016-07-21 00:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:06:29 UTC to 2016-07-21 01:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:26:29 UTC to 2016-07-21 01:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:46:29 UTC to 2016-07-21 01:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:06:29 UTC to 2016-07-21 02:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:26:29 UTC to 2016-07-21 02:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:46:29 UTC to 2016-07-21 02:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:06:29 UTC to 2016-07-21 03:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:26:29 UTC to 2016-07-21 03:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:46:29 UTC to 2016-07-21 03:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:06:29 UTC to 2016-07-21 04:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:26:29 UTC to 2016-07-21 04:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:46:29 UTC to 2016-07-21 04:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:06:29 UTC to 2016-07-21 05:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:26:29 UTC to 2016-07-21 05:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:46:29 UTC to 2016-07-21 05:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:06:29 UTC to 2016-07-21 06:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:26:29 UTC to 2016-07-21 06:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:46:29 UTC to 2016-07-21 06:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:06:29 UTC to 2016-07-21 07:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:26:29 UTC to 2016-07-21 07:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:46:29 UTC to 2016-07-21 07:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:06:29 UTC to 2016-07-21 08:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:26:29 UTC to 2016-07-21 08:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:46:29 UTC to 2016-07-21 08:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:06:29 UTC to 2016-07-21 09:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:26:29 UTC to 2016-07-21 09:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:46:29 UTC to 2016-07-21 09:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:06:29 UTC to 2016-07-21 10:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:26:29 UTC to 2016-07-21 10:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:46:29 UTC to 2016-07-21 10:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:06:29 UTC to 2016-07-21 11:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:26:29 UTC to 2016-07-21 11:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:46:29 UTC to 2016-07-21 11:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:06:29 UTC to 2016-07-21 12:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:26:29 UTC to 2016-07-21 12:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:46:28 UTC to 2016-07-21 12:46:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:05:48 UTC to 2016-07-22 17:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:25:48 UTC to 2016-07-22 17:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:45:48 UTC to 2016-07-22 17:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:05:48 UTC to 2016-07-22 18:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:25:48 UTC to 2016-07-22 18:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:45:48 UTC to 2016-07-22 18:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:05:48 UTC to 2016-07-22 19:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:25:48 UTC to 2016-07-22 19:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:45:48 UTC to 2016-07-22 19:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:05:48 UTC to 2016-07-22 20:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:25:48 UTC to 2016-07-22 20:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:45:48 UTC to 2016-07-22 20:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:05:48 UTC to 2016-07-22 21:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:25:48 UTC to 2016-07-22 21:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:45:48 UTC to 2016-07-22 21:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:05:48 UTC to 2016-07-22 22:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:25:48 UTC to 2016-07-22 22:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:45:48 UTC to 2016-07-22 22:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:05:48 UTC to 2016-07-22 23:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:25:48 UTC to 2016-07-22 23:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:45:48 UTC to 2016-07-22 23:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:05:48 UTC to 2016-07-23 00:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:25:48 UTC to 2016-07-23 00:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:45:48 UTC to 2016-07-23 00:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:05:47 UTC to 2016-07-23 01:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:25:47 UTC to 2016-07-23 01:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:45:47 UTC to 2016-07-23 01:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:05:47 UTC to 2016-07-23 02:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:25:47 UTC to 2016-07-23 02:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:45:47 UTC to 2016-07-23 02:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:05:47 UTC to 2016-07-23 03:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:25:47 UTC to 2016-07-23 03:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:45:47 UTC to 2016-07-23 03:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:05:47 UTC to 2016-07-23 04:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:25:47 UTC to 2016-07-23 04:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:45:47 UTC to 2016-07-23 04:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:05:47 UTC to 2016-07-23 05:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:25:47 UTC to 2016-07-23 05:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:45:47 UTC to 2016-07-23 05:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:05:47 UTC to 2016-07-23 06:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:25:47 UTC to 2016-07-23 06:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:45:47 UTC to 2016-07-23 06:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:05:47 UTC to 2016-07-23 07:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:25:47 UTC to 2016-07-23 07:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:45:47 UTC to 2016-07-23 07:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:05:47 UTC to 2016-07-23 08:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:25:47 UTC to 2016-07-23 08:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:45:47 UTC to 2016-07-23 08:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:05:47 UTC to 2016-07-23 09:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:25:47 UTC to 2016-07-23 09:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:45:47 UTC to 2016-07-23 09:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:05:47 UTC to 2016-07-23 10:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:25:47 UTC to 2016-07-23 10:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:45:47 UTC to 2016-07-23 10:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:05:47 UTC to 2016-07-23 11:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:25:47 UTC to 2016-07-23 11:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:45:47 UTC to 2016-07-23 11:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:05:47 UTC to 2016-07-23 12:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:25:47 UTC to 2016-07-23 12:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:45:47 UTC to 2016-07-23 12:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:05:47 UTC to 2016-07-23 13:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:25:47 UTC to 2016-07-23 13:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:45:47 UTC to 2016-07-23 13:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:05:47 UTC to 2016-07-23 14:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:25:47 UTC to 2016-07-23 14:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:45:47 UTC to 2016-07-23 14:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:05:47 UTC to 2016-07-23 15:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:25:47 UTC to 2016-07-23 15:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:45:47 UTC to 2016-07-23 15:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:05:47 UTC to 2016-07-23 16:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:25:47 UTC to 2016-07-23 16:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:45:47 UTC to 2016-07-23 16:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:05:47 UTC to 2016-07-23 17:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:25:47 UTC to 2016-07-23 17:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:45:47 UTC to 2016-07-23 17:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:05:47 UTC to 2016-07-23 18:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:25:47 UTC to 2016-07-23 18:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:45:47 UTC to 2016-07-23 18:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:05:47 UTC to 2016-07-23 19:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:25:47 UTC to 2016-07-23 19:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:45:47 UTC to 2016-07-23 19:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:05:47 UTC to 2016-07-23 20:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:25:47 UTC to 2016-07-23 20:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:45:47 UTC to 2016-07-23 20:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:05:47 UTC to 2016-07-23 21:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:25:47 UTC to 2016-07-23 21:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:45:47 UTC to 2016-07-23 21:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:05:47 UTC to 2016-07-23 22:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:25:47 UTC to 2016-07-23 22:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:45:47 UTC to 2016-07-23 22:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:05:47 UTC to 2016-07-23 23:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:25:47 UTC to 2016-07-23 23:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:45:47 UTC to 2016-07-23 23:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:05:47 UTC to 2016-07-24 00:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:25:47 UTC to 2016-07-24 00:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:45:47 UTC to 2016-07-24 00:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:05:47 UTC to 2016-07-24 01:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:25:47 UTC to 2016-07-24 01:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:45:47 UTC to 2016-07-24 01:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:05:47 UTC to 2016-07-24 02:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:25:47 UTC to 2016-07-24 02:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:45:47 UTC to 2016-07-24 02:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:05:46 UTC to 2016-07-24 03:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:25:47 UTC to 2016-07-24 03:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:45:46 UTC to 2016-07-24 03:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:05:46 UTC to 2016-07-24 04:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:25:46 UTC to 2016-07-24 04:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:45:46 UTC to 2016-07-24 04:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:05:46 UTC to 2016-07-24 05:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:25:46 UTC to 2016-07-24 05:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:45:46 UTC to 2016-07-24 05:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:05:46 UTC to 2016-07-24 06:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:25:46 UTC to 2016-07-24 06:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:45:46 UTC to 2016-07-24 06:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:05:46 UTC to 2016-07-24 07:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:25:46 UTC to 2016-07-24 07:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:45:46 UTC to 2016-07-24 07:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:05:46 UTC to 2016-07-24 08:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:25:46 UTC to 2016-07-24 08:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:45:46 UTC to 2016-07-24 08:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:05:46 UTC to 2016-07-24 09:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:25:46 UTC to 2016-07-24 09:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:45:46 UTC to 2016-07-24 09:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:05:46 UTC to 2016-07-24 10:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:25:46 UTC to 2016-07-24 10:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:45:46 UTC to 2016-07-24 10:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 11:05:46 UTC to 2016-07-24 11:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 11:25:46 UTC to 2016-07-24 11:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 00:50:03 UTC to 2016-07-25 00:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:00:03 UTC to 2016-07-25 01:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:20:03 UTC to 2016-07-25 01:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:40:03 UTC to 2016-07-25 01:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:00:03 UTC to 2016-07-25 02:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:20:03 UTC to 2016-07-25 02:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:40:03 UTC to 2016-07-25 02:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:00:03 UTC to 2016-07-25 03:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:20:03 UTC to 2016-07-25 03:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:40:03 UTC to 2016-07-25 03:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:00:03 UTC to 2016-07-25 04:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:20:03 UTC to 2016-07-25 04:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:40:03 UTC to 2016-07-25 04:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:00:03 UTC to 2016-07-25 05:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:20:03 UTC to 2016-07-25 05:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:40:03 UTC to 2016-07-25 05:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:00:03 UTC to 2016-07-25 06:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:20:03 UTC to 2016-07-25 06:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:40:03 UTC to 2016-07-25 06:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:00:03 UTC to 2016-07-25 07:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:20:03 UTC to 2016-07-25 07:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:40:03 UTC to 2016-07-25 07:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:00:03 UTC to 2016-07-25 08:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:20:03 UTC to 2016-07-25 08:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:40:03 UTC to 2016-07-25 08:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:00:03 UTC to 2016-07-25 09:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:20:03 UTC to 2016-07-25 09:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:40:03 UTC to 2016-07-25 09:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:00:03 UTC to 2016-07-25 10:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:20:03 UTC to 2016-07-25 10:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:40:03 UTC to 2016-07-25 10:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:00:02 UTC to 2016-07-25 11:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:20:02 UTC to 2016-07-25 11:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:40:03 UTC to 2016-07-25 11:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:00:02 UTC to 2016-07-25 12:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:20:02 UTC to 2016-07-25 12:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:40:02 UTC to 2016-07-25 12:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:00:02 UTC to 2016-07-25 13:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:20:02 UTC to 2016-07-25 13:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:40:02 UTC to 2016-07-25 13:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:00:02 UTC to 2016-07-25 14:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:20:02 UTC to 2016-07-25 14:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:40:02 UTC to 2016-07-25 14:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:00:02 UTC to 2016-07-25 15:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:20:02 UTC to 2016-07-25 15:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:40:02 UTC to 2016-07-25 15:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:00:02 UTC to 2016-07-25 16:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:20:02 UTC to 2016-07-25 16:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:40:02 UTC to 2016-07-25 16:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:00:02 UTC to 2016-07-25 17:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:20:02 UTC to 2016-07-25 17:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:40:02 UTC to 2016-07-25 17:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:00:02 UTC to 2016-07-25 18:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:20:02 UTC to 2016-07-25 18:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:40:02 UTC to 2016-07-25 18:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:00:02 UTC to 2016-07-25 19:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:20:02 UTC to 2016-07-25 19:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:40:02 UTC to 2016-07-25 19:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:00:02 UTC to 2016-07-25 20:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:20:02 UTC to 2016-07-25 20:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:40:02 UTC to 2016-07-25 20:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:00:02 UTC to 2016-07-25 21:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:20:02 UTC to 2016-07-25 21:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:40:02 UTC to 2016-07-25 21:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:00:02 UTC to 2016-07-25 22:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:20:02 UTC to 2016-07-25 22:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:40:02 UTC to 2016-07-25 22:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:00:02 UTC to 2016-07-25 23:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:20:02 UTC to 2016-07-25 23:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:40:02 UTC to 2016-07-25 23:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:00:02 UTC to 2016-07-26 00:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:20:02 UTC to 2016-07-26 00:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:40:02 UTC to 2016-07-26 00:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:00:02 UTC to 2016-07-26 01:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:20:02 UTC to 2016-07-26 01:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:40:02 UTC to 2016-07-26 01:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:00:02 UTC to 2016-07-26 02:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:20:02 UTC to 2016-07-26 02:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:40:02 UTC to 2016-07-26 02:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:00:02 UTC to 2016-07-26 03:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:20:02 UTC to 2016-07-26 03:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:40:02 UTC to 2016-07-26 03:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:00:02 UTC to 2016-07-26 04:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:20:02 UTC to 2016-07-26 04:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:40:02 UTC to 2016-07-26 04:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:00:02 UTC to 2016-07-26 05:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:20:02 UTC to 2016-07-26 05:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:40:02 UTC to 2016-07-26 05:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:00:02 UTC to 2016-07-26 06:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:20:02 UTC to 2016-07-26 06:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:40:02 UTC to 2016-07-26 06:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 07:00:02 UTC to 2016-07-26 07:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 07:20:02 UTC to 2016-07-26 07:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 15:37:03 UTC to 2016-07-28 15:37:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 15:47:03 UTC to 2016-07-28 15:47:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:07:03 UTC to 2016-07-28 16:07:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:27:03 UTC to 2016-07-28 16:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:47:02 UTC to 2016-07-28 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:07:02 UTC to 2016-07-28 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:27:02 UTC to 2016-07-28 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:47:02 UTC to 2016-07-28 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:07:02 UTC to 2016-07-28 18:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:27:03 UTC to 2016-07-28 18:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:47:02 UTC to 2016-07-28 18:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:07:02 UTC to 2016-07-28 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:27:02 UTC to 2016-07-28 19:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:47:02 UTC to 2016-07-28 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:07:02 UTC to 2016-07-28 20:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:27:02 UTC to 2016-07-28 20:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:47:02 UTC to 2016-07-28 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:07:02 UTC to 2016-07-28 21:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:27:02 UTC to 2016-07-28 21:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:47:02 UTC to 2016-07-28 21:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:07:02 UTC to 2016-07-28 22:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:27:03 UTC to 2016-07-28 22:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:47:02 UTC to 2016-07-28 22:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:07:02 UTC to 2016-07-28 23:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:27:02 UTC to 2016-07-28 23:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:47:02 UTC to 2016-07-28 23:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:07:02 UTC to 2016-07-29 00:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:27:02 UTC to 2016-07-29 00:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:47:02 UTC to 2016-07-29 00:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:07:02 UTC to 2016-07-29 01:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:27:02 UTC to 2016-07-29 01:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:47:03 UTC to 2016-07-29 01:47:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:07:02 UTC to 2016-07-29 02:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:27:02 UTC to 2016-07-29 02:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:47:02 UTC to 2016-07-29 02:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:07:02 UTC to 2016-07-29 03:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:27:02 UTC to 2016-07-29 03:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:47:02 UTC to 2016-07-29 03:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:07:02 UTC to 2016-07-29 04:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:27:02 UTC to 2016-07-29 04:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:47:02 UTC to 2016-07-29 04:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:07:02 UTC to 2016-07-29 05:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:27:02 UTC to 2016-07-29 05:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:47:02 UTC to 2016-07-29 05:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:07:02 UTC to 2016-07-29 06:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:27:02 UTC to 2016-07-29 06:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:47:02 UTC to 2016-07-29 06:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:07:02 UTC to 2016-07-29 07:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:27:02 UTC to 2016-07-29 07:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:47:02 UTC to 2016-07-29 07:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:07:02 UTC to 2016-07-29 08:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:27:02 UTC to 2016-07-29 08:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:47:02 UTC to 2016-07-29 08:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:07:02 UTC to 2016-07-29 09:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:27:02 UTC to 2016-07-29 09:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:47:02 UTC to 2016-07-29 09:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:07:02 UTC to 2016-07-29 10:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:27:02 UTC to 2016-07-29 10:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:47:02 UTC to 2016-07-29 10:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:07:02 UTC to 2016-07-29 11:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:27:02 UTC to 2016-07-29 11:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:47:02 UTC to 2016-07-29 11:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:07:02 UTC to 2016-07-29 12:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:27:02 UTC to 2016-07-29 12:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:47:02 UTC to 2016-07-29 12:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:07:02 UTC to 2016-07-29 13:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:27:02 UTC to 2016-07-29 13:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:47:02 UTC to 2016-07-29 13:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:07:02 UTC to 2016-07-29 14:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:27:02 UTC to 2016-07-29 14:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:47:02 UTC to 2016-07-29 14:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:07:02 UTC to 2016-07-29 15:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:27:02 UTC to 2016-07-29 15:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:47:02 UTC to 2016-07-29 15:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:07:02 UTC to 2016-07-29 16:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:27:02 UTC to 2016-07-29 16:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:47:02 UTC to 2016-07-29 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:07:02 UTC to 2016-07-29 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:27:02 UTC to 2016-07-29 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:47:02 UTC to 2016-07-29 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:07:02 UTC to 2016-07-29 18:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:27:02 UTC to 2016-07-29 18:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:47:01 UTC to 2016-07-29 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:07:02 UTC to 2016-07-29 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:27:01 UTC to 2016-07-29 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:47:02 UTC to 2016-07-29 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:07:01 UTC to 2016-07-29 20:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:27:01 UTC to 2016-07-29 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:47:02 UTC to 2016-07-29 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:07:01 UTC to 2016-07-29 21:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:27:01 UTC to 2016-07-29 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:47:01 UTC to 2016-07-29 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:07:01 UTC to 2016-07-29 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:27:02 UTC to 2016-07-29 22:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:47:01 UTC to 2016-07-29 22:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:07:01 UTC to 2016-07-29 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:27:01 UTC to 2016-07-29 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:47:01 UTC to 2016-07-29 23:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:07:01 UTC to 2016-07-30 00:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:27:01 UTC to 2016-07-30 00:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:47:01 UTC to 2016-07-30 00:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:07:01 UTC to 2016-07-30 01:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:27:01 UTC to 2016-07-30 01:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:47:01 UTC to 2016-07-30 01:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:07:01 UTC to 2016-07-30 02:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:27:01 UTC to 2016-07-30 02:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:47:01 UTC to 2016-07-30 02:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:07:01 UTC to 2016-07-30 03:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:27:01 UTC to 2016-07-30 03:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:47:01 UTC to 2016-07-30 03:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:07:01 UTC to 2016-07-30 04:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:27:01 UTC to 2016-07-30 04:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:47:01 UTC to 2016-07-30 04:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:07:01 UTC to 2016-07-30 05:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:27:01 UTC to 2016-07-30 05:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:47:01 UTC to 2016-07-30 05:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:07:01 UTC to 2016-07-30 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:27:01 UTC to 2016-07-30 06:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:47:01 UTC to 2016-07-30 06:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:07:01 UTC to 2016-07-30 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:27:01 UTC to 2016-07-30 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:47:01 UTC to 2016-07-30 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:07:01 UTC to 2016-07-30 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:27:01 UTC to 2016-07-30 08:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:47:01 UTC to 2016-07-30 08:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:07:01 UTC to 2016-07-30 09:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:27:01 UTC to 2016-07-30 09:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:47:01 UTC to 2016-07-30 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:07:01 UTC to 2016-07-30 10:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:27:01 UTC to 2016-07-30 10:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:47:01 UTC to 2016-07-30 10:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:07:01 UTC to 2016-07-30 11:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:27:01 UTC to 2016-07-30 11:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:47:01 UTC to 2016-07-30 11:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:07:01 UTC to 2016-07-30 12:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:27:01 UTC to 2016-07-30 12:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:47:01 UTC to 2016-07-30 12:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:07:01 UTC to 2016-07-30 13:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:27:01 UTC to 2016-07-30 13:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:47:01 UTC to 2016-07-30 13:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:07:01 UTC to 2016-07-30 14:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:27:01 UTC to 2016-07-30 14:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:47:01 UTC to 2016-07-30 14:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:07:01 UTC to 2016-07-30 15:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:27:01 UTC to 2016-07-30 15:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:47:01 UTC to 2016-07-30 15:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:07:01 UTC to 2016-07-30 16:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:27:01 UTC to 2016-07-30 16:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:47:01 UTC to 2016-07-30 16:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:07:01 UTC to 2016-07-30 17:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:27:01 UTC to 2016-07-30 17:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:47:01 UTC to 2016-07-30 17:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:07:01 UTC to 2016-07-30 18:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:27:01 UTC to 2016-07-30 18:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:47:01 UTC to 2016-07-30 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:07:01 UTC to 2016-07-30 19:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:27:01 UTC to 2016-07-30 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:47:01 UTC to 2016-07-30 19:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:07:00 UTC to 2016-07-30 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:27:01 UTC to 2016-07-30 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:47:01 UTC to 2016-07-30 20:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:07:00 UTC to 2016-07-30 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:27:01 UTC to 2016-07-30 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:47:01 UTC to 2016-07-30 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:07:01 UTC to 2016-07-30 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:27:00 UTC to 2016-07-30 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:47:00 UTC to 2016-07-30 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:07:01 UTC to 2016-07-30 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:27:01 UTC to 2016-07-30 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:47:00 UTC to 2016-07-30 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:07:00 UTC to 2016-07-31 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:27:00 UTC to 2016-07-31 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:47:00 UTC to 2016-07-31 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:07:00 UTC to 2016-07-31 01:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:27:00 UTC to 2016-07-31 01:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:47:00 UTC to 2016-07-31 01:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:07:00 UTC to 2016-07-31 02:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:27:00 UTC to 2016-07-31 02:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:47:00 UTC to 2016-07-31 02:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:07:00 UTC to 2016-07-31 03:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:27:00 UTC to 2016-07-31 03:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:47:00 UTC to 2016-07-31 03:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:07:00 UTC to 2016-07-31 04:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:27:00 UTC to 2016-07-31 04:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:47:00 UTC to 2016-07-31 04:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:07:00 UTC to 2016-07-31 05:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:27:00 UTC to 2016-07-31 05:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:47:00 UTC to 2016-07-31 05:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:07:00 UTC to 2016-07-31 06:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:27:00 UTC to 2016-07-31 06:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:47:00 UTC to 2016-07-31 06:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:07:00 UTC to 2016-07-31 07:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:27:00 UTC to 2016-07-31 07:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:47:00 UTC to 2016-07-31 07:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:07:00 UTC to 2016-07-31 08:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:27:00 UTC to 2016-07-31 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:47:00 UTC to 2016-07-31 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:07:00 UTC to 2016-07-31 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:27:00 UTC to 2016-07-31 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:47:00 UTC to 2016-07-31 09:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:07:00 UTC to 2016-07-31 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:27:00 UTC to 2016-07-31 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:47:00 UTC to 2016-07-31 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:07:00 UTC to 2016-07-31 11:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:27:00 UTC to 2016-07-31 11:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:47:00 UTC to 2016-07-31 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:07:00 UTC to 2016-07-31 12:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:27:00 UTC to 2016-07-31 12:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:47:00 UTC to 2016-07-31 12:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:07:00 UTC to 2016-07-31 13:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:27:00 UTC to 2016-07-31 13:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:47:00 UTC to 2016-07-31 13:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:07:00 UTC to 2016-07-31 14:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:27:00 UTC to 2016-07-31 14:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:47:00 UTC to 2016-07-31 14:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:07:00 UTC to 2016-07-31 15:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:27:00 UTC to 2016-07-31 15:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:47:00 UTC to 2016-07-31 15:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:07:00 UTC to 2016-07-31 16:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:27:00 UTC to 2016-07-31 16:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:47:00 UTC to 2016-07-31 16:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:07:00 UTC to 2016-07-31 17:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:27:00 UTC to 2016-07-31 17:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:47:00 UTC to 2016-07-31 17:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:07:00 UTC to 2016-07-31 18:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:27:00 UTC to 2016-07-31 18:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:47:00 UTC to 2016-07-31 18:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:07:00 UTC to 2016-07-31 19:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:27:00 UTC to 2016-07-31 19:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:47:00 UTC to 2016-07-31 19:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:07:00 UTC to 2016-07-31 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:27:00 UTC to 2016-07-31 20:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:47:00 UTC to 2016-07-31 20:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:07:00 UTC to 2016-07-31 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:27:00 UTC to 2016-07-31 21:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:47:00 UTC to 2016-07-31 21:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:07:00 UTC to 2016-07-31 22:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:27:00 UTC to 2016-07-31 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:47:00 UTC to 2016-07-31 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:07:00 UTC to 2016-07-31 23:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:26:59 UTC to 2016-07-31 23:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:47:00 UTC to 2016-07-31 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:07:00 UTC to 2016-08-01 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:27:00 UTC to 2016-08-01 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:47:00 UTC to 2016-08-01 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:06:59 UTC to 2016-08-01 01:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:26:59 UTC to 2016-08-01 01:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:46:59 UTC to 2016-08-01 01:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:06:59 UTC to 2016-08-01 02:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:26:59 UTC to 2016-08-01 02:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:46:59 UTC to 2016-08-01 02:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 03:06:59 UTC to 2016-08-01 03:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 03:26:59 UTC to 2016-08-01 03:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-01 08:11:40 UTC to 2016-07-01 08:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 08:31:40 UTC to 2016-07-01 08:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 08:51:40 UTC to 2016-07-01 08:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:11:40 UTC to 2016-07-01 09:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:31:40 UTC to 2016-07-01 09:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:51:40 UTC to 2016-07-01 09:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:11:40 UTC to 2016-07-01 10:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:31:40 UTC to 2016-07-01 10:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:51:40 UTC to 2016-07-01 10:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:11:40 UTC to 2016-07-01 11:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:31:40 UTC to 2016-07-01 11:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:51:40 UTC to 2016-07-01 11:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:11:40 UTC to 2016-07-01 12:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:31:50 UTC to 2016-07-01 12:32:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:51:40 UTC to 2016-07-01 12:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:11:40 UTC to 2016-07-01 13:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:31:40 UTC to 2016-07-01 13:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:51:40 UTC to 2016-07-01 13:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:11:40 UTC to 2016-07-01 14:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:31:40 UTC to 2016-07-01 14:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:51:40 UTC to 2016-07-01 14:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:11:40 UTC to 2016-07-01 15:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:31:40 UTC to 2016-07-01 15:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:51:40 UTC to 2016-07-01 15:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:11:40 UTC to 2016-07-01 16:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:31:40 UTC to 2016-07-01 16:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:51:40 UTC to 2016-07-01 16:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:11:40 UTC to 2016-07-01 17:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:31:40 UTC to 2016-07-01 17:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:51:40 UTC to 2016-07-01 17:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:11:40 UTC to 2016-07-01 18:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:31:40 UTC to 2016-07-01 18:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:51:40 UTC to 2016-07-01 18:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:11:40 UTC to 2016-07-01 19:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:31:40 UTC to 2016-07-01 19:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:51:40 UTC to 2016-07-01 19:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:11:40 UTC to 2016-07-01 20:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:31:40 UTC to 2016-07-01 20:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:51:40 UTC to 2016-07-01 20:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:11:40 UTC to 2016-07-01 21:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:31:40 UTC to 2016-07-01 21:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:51:40 UTC to 2016-07-01 21:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:11:40 UTC to 2016-07-01 22:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:31:40 UTC to 2016-07-01 22:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:51:40 UTC to 2016-07-01 22:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:11:40 UTC to 2016-07-01 23:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:31:40 UTC to 2016-07-01 23:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:51:40 UTC to 2016-07-01 23:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:11:40 UTC to 2016-07-02 00:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:31:40 UTC to 2016-07-02 00:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:51:40 UTC to 2016-07-02 00:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:11:40 UTC to 2016-07-02 01:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:31:40 UTC to 2016-07-02 01:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:51:40 UTC to 2016-07-02 01:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:11:40 UTC to 2016-07-02 02:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:31:40 UTC to 2016-07-02 02:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:51:40 UTC to 2016-07-02 02:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:11:40 UTC to 2016-07-02 03:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:31:40 UTC to 2016-07-02 03:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:51:40 UTC to 2016-07-02 03:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:11:39 UTC to 2016-07-02 04:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:31:40 UTC to 2016-07-02 04:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:51:39 UTC to 2016-07-02 04:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:11:39 UTC to 2016-07-02 05:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:31:39 UTC to 2016-07-02 05:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:51:39 UTC to 2016-07-02 05:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:11:39 UTC to 2016-07-02 06:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:31:39 UTC to 2016-07-02 06:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:51:39 UTC to 2016-07-02 06:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:11:39 UTC to 2016-07-02 07:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:31:39 UTC to 2016-07-02 07:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:51:39 UTC to 2016-07-02 07:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:11:39 UTC to 2016-07-02 08:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:31:39 UTC to 2016-07-02 08:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:51:39 UTC to 2016-07-02 08:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:11:39 UTC to 2016-07-02 09:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:31:39 UTC to 2016-07-02 09:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:51:39 UTC to 2016-07-02 09:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:11:39 UTC to 2016-07-02 10:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:31:39 UTC to 2016-07-02 10:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:51:39 UTC to 2016-07-02 10:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:11:39 UTC to 2016-07-02 11:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:31:39 UTC to 2016-07-02 11:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:51:39 UTC to 2016-07-02 11:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:11:39 UTC to 2016-07-02 12:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:31:39 UTC to 2016-07-02 12:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:51:39 UTC to 2016-07-02 12:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:11:39 UTC to 2016-07-02 13:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:31:39 UTC to 2016-07-02 13:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:51:39 UTC to 2016-07-02 13:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:11:39 UTC to 2016-07-02 14:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:31:39 UTC to 2016-07-02 14:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:51:39 UTC to 2016-07-02 14:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:11:39 UTC to 2016-07-02 15:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:31:39 UTC to 2016-07-02 15:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:51:39 UTC to 2016-07-02 15:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:11:39 UTC to 2016-07-02 16:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:31:39 UTC to 2016-07-02 16:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:51:39 UTC to 2016-07-02 16:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:11:39 UTC to 2016-07-02 17:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:31:39 UTC to 2016-07-02 17:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:51:39 UTC to 2016-07-02 17:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:11:39 UTC to 2016-07-02 18:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:31:39 UTC to 2016-07-02 18:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:51:39 UTC to 2016-07-02 18:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:11:39 UTC to 2016-07-02 19:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:31:39 UTC to 2016-07-02 19:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:51:39 UTC to 2016-07-02 19:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:11:39 UTC to 2016-07-02 20:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:31:39 UTC to 2016-07-02 20:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:51:39 UTC to 2016-07-02 20:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:11:39 UTC to 2016-07-02 21:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:31:39 UTC to 2016-07-02 21:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:51:39 UTC to 2016-07-02 21:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:11:39 UTC to 2016-07-02 22:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:31:39 UTC to 2016-07-02 22:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:51:39 UTC to 2016-07-02 22:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:11:39 UTC to 2016-07-02 23:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:31:39 UTC to 2016-07-02 23:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:51:39 UTC to 2016-07-02 23:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:11:39 UTC to 2016-07-03 00:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:31:39 UTC to 2016-07-03 00:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:51:39 UTC to 2016-07-03 00:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:11:39 UTC to 2016-07-03 01:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:31:39 UTC to 2016-07-03 01:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:51:39 UTC to 2016-07-03 01:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:11:39 UTC to 2016-07-03 02:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:31:39 UTC to 2016-07-03 02:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:51:39 UTC to 2016-07-03 02:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:11:39 UTC to 2016-07-03 03:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:31:39 UTC to 2016-07-03 03:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:51:39 UTC to 2016-07-03 03:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:11:39 UTC to 2016-07-03 04:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:31:39 UTC to 2016-07-03 04:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:51:39 UTC to 2016-07-03 04:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:11:39 UTC to 2016-07-03 05:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:31:39 UTC to 2016-07-03 05:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:51:39 UTC to 2016-07-03 05:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:11:39 UTC to 2016-07-03 06:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:31:39 UTC to 2016-07-03 06:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:51:39 UTC to 2016-07-03 06:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:11:39 UTC to 2016-07-03 07:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:31:39 UTC to 2016-07-03 07:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:51:39 UTC to 2016-07-03 07:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:11:39 UTC to 2016-07-03 08:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:31:38 UTC to 2016-07-03 08:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:51:38 UTC to 2016-07-03 08:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:11:38 UTC to 2016-07-03 09:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:31:38 UTC to 2016-07-03 09:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:51:38 UTC to 2016-07-03 09:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:11:38 UTC to 2016-07-03 10:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:31:38 UTC to 2016-07-03 10:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:51:38 UTC to 2016-07-03 10:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:11:38 UTC to 2016-07-03 11:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:31:38 UTC to 2016-07-03 11:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:51:38 UTC to 2016-07-03 11:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:11:38 UTC to 2016-07-03 12:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:31:38 UTC to 2016-07-03 12:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:51:38 UTC to 2016-07-03 12:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:11:38 UTC to 2016-07-03 13:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:31:38 UTC to 2016-07-03 13:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:51:38 UTC to 2016-07-03 13:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:11:38 UTC to 2016-07-03 14:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:31:38 UTC to 2016-07-03 14:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:51:38 UTC to 2016-07-03 14:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:11:38 UTC to 2016-07-03 15:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:31:38 UTC to 2016-07-03 15:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:51:38 UTC to 2016-07-03 15:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:11:38 UTC to 2016-07-03 16:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:31:38 UTC to 2016-07-03 16:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:51:38 UTC to 2016-07-03 16:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:11:38 UTC to 2016-07-03 17:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:31:38 UTC to 2016-07-03 17:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:51:38 UTC to 2016-07-03 17:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:11:38 UTC to 2016-07-03 18:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:31:38 UTC to 2016-07-03 18:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:51:38 UTC to 2016-07-03 18:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:11:38 UTC to 2016-07-03 19:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:31:38 UTC to 2016-07-03 19:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:51:38 UTC to 2016-07-03 19:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:11:38 UTC to 2016-07-03 20:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:31:38 UTC to 2016-07-03 20:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:51:38 UTC to 2016-07-03 20:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:11:38 UTC to 2016-07-03 21:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:31:38 UTC to 2016-07-03 21:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:51:38 UTC to 2016-07-03 21:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:11:38 UTC to 2016-07-03 22:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:31:38 UTC to 2016-07-03 22:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:51:38 UTC to 2016-07-03 22:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:11:38 UTC to 2016-07-03 23:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:31:38 UTC to 2016-07-03 23:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:51:38 UTC to 2016-07-03 23:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:11:38 UTC to 2016-07-04 00:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:31:38 UTC to 2016-07-04 00:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:51:38 UTC to 2016-07-04 00:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:11:38 UTC to 2016-07-04 01:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:31:38 UTC to 2016-07-04 01:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:51:38 UTC to 2016-07-04 01:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:11:38 UTC to 2016-07-04 02:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:31:38 UTC to 2016-07-04 02:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:51:38 UTC to 2016-07-04 02:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:11:38 UTC to 2016-07-04 03:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:31:38 UTC to 2016-07-04 03:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:51:38 UTC to 2016-07-04 03:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:11:38 UTC to 2016-07-04 04:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:31:38 UTC to 2016-07-04 04:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:51:38 UTC to 2016-07-04 04:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:11:38 UTC to 2016-07-04 05:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:31:38 UTC to 2016-07-04 05:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:51:38 UTC to 2016-07-04 05:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:11:38 UTC to 2016-07-04 06:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:31:38 UTC to 2016-07-04 06:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:51:38 UTC to 2016-07-04 06:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:11:38 UTC to 2016-07-04 07:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:31:38 UTC to 2016-07-04 07:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:51:38 UTC to 2016-07-04 07:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:11:38 UTC to 2016-07-04 08:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:31:38 UTC to 2016-07-04 08:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:51:38 UTC to 2016-07-04 08:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:18:19 UTC to 2016-07-05 02:18:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:28:18 UTC to 2016-07-05 02:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:48:18 UTC to 2016-07-05 02:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:08:18 UTC to 2016-07-05 03:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:28:18 UTC to 2016-07-05 03:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:48:18 UTC to 2016-07-05 03:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:08:18 UTC to 2016-07-05 04:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:28:18 UTC to 2016-07-05 04:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:48:18 UTC to 2016-07-05 04:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:08:18 UTC to 2016-07-05 05:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:28:18 UTC to 2016-07-05 05:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:48:18 UTC to 2016-07-05 05:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:08:18 UTC to 2016-07-05 06:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:28:18 UTC to 2016-07-05 06:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:48:18 UTC to 2016-07-05 06:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:08:18 UTC to 2016-07-05 07:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:28:18 UTC to 2016-07-05 07:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:48:18 UTC to 2016-07-05 07:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:08:18 UTC to 2016-07-05 08:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:28:18 UTC to 2016-07-05 08:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:48:18 UTC to 2016-07-05 08:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:08:18 UTC to 2016-07-05 09:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:28:18 UTC to 2016-07-05 09:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:48:18 UTC to 2016-07-05 09:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:08:18 UTC to 2016-07-05 10:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:28:18 UTC to 2016-07-05 10:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:48:18 UTC to 2016-07-05 10:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:08:18 UTC to 2016-07-05 11:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:28:18 UTC to 2016-07-05 11:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:48:18 UTC to 2016-07-05 11:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:08:18 UTC to 2016-07-05 12:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:28:18 UTC to 2016-07-05 12:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:48:18 UTC to 2016-07-05 12:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:08:18 UTC to 2016-07-05 13:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:28:18 UTC to 2016-07-05 13:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:48:18 UTC to 2016-07-05 13:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:08:18 UTC to 2016-07-05 14:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:28:18 UTC to 2016-07-05 14:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:48:18 UTC to 2016-07-05 14:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:08:18 UTC to 2016-07-05 15:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:28:18 UTC to 2016-07-05 15:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:48:18 UTC to 2016-07-05 15:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:08:18 UTC to 2016-07-05 16:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:28:18 UTC to 2016-07-05 16:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:48:18 UTC to 2016-07-05 16:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:08:18 UTC to 2016-07-05 17:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:28:18 UTC to 2016-07-05 17:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:48:18 UTC to 2016-07-05 17:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:08:18 UTC to 2016-07-05 18:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:28:18 UTC to 2016-07-05 18:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:48:18 UTC to 2016-07-05 18:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:08:18 UTC to 2016-07-05 19:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:28:18 UTC to 2016-07-05 19:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:48:18 UTC to 2016-07-05 19:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:08:18 UTC to 2016-07-05 20:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:28:18 UTC to 2016-07-05 20:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:48:18 UTC to 2016-07-05 20:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:08:18 UTC to 2016-07-05 21:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:28:18 UTC to 2016-07-05 21:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:48:18 UTC to 2016-07-05 21:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:08:18 UTC to 2016-07-05 22:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:28:18 UTC to 2016-07-05 22:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:48:18 UTC to 2016-07-05 22:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:08:18 UTC to 2016-07-05 23:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:28:18 UTC to 2016-07-05 23:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:48:17 UTC to 2016-07-05 23:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:08:18 UTC to 2016-07-06 00:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:28:18 UTC to 2016-07-06 00:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:48:18 UTC to 2016-07-06 00:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:08:18 UTC to 2016-07-06 01:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:28:17 UTC to 2016-07-06 01:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:48:17 UTC to 2016-07-06 01:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:08:18 UTC to 2016-07-06 02:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:28:17 UTC to 2016-07-06 02:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:48:17 UTC to 2016-07-06 02:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:08:17 UTC to 2016-07-06 03:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:28:17 UTC to 2016-07-06 03:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:48:17 UTC to 2016-07-06 03:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:08:17 UTC to 2016-07-06 04:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:28:17 UTC to 2016-07-06 04:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:48:17 UTC to 2016-07-06 04:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:08:17 UTC to 2016-07-06 05:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:28:17 UTC to 2016-07-06 05:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:48:17 UTC to 2016-07-06 05:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:08:17 UTC to 2016-07-06 06:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:28:17 UTC to 2016-07-06 06:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:48:17 UTC to 2016-07-06 06:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:08:17 UTC to 2016-07-06 07:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:28:17 UTC to 2016-07-06 07:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:48:17 UTC to 2016-07-06 07:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:08:17 UTC to 2016-07-06 08:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:28:17 UTC to 2016-07-06 08:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:48:17 UTC to 2016-07-06 08:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:08:17 UTC to 2016-07-06 09:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:28:17 UTC to 2016-07-06 09:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:48:17 UTC to 2016-07-06 09:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:08:17 UTC to 2016-07-06 10:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:28:17 UTC to 2016-07-06 10:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:48:17 UTC to 2016-07-06 10:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:08:17 UTC to 2016-07-06 11:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:28:17 UTC to 2016-07-06 11:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:48:17 UTC to 2016-07-06 11:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:08:17 UTC to 2016-07-06 12:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:28:17 UTC to 2016-07-06 12:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:48:17 UTC to 2016-07-06 12:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:08:17 UTC to 2016-07-06 13:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:28:17 UTC to 2016-07-06 13:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:48:17 UTC to 2016-07-06 13:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:08:17 UTC to 2016-07-06 14:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:28:17 UTC to 2016-07-06 14:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:48:17 UTC to 2016-07-06 14:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 15:28:17 UTC to 2016-07-06 15:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 15:48:17 UTC to 2016-07-06 15:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:08:17 UTC to 2016-07-06 16:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:28:17 UTC to 2016-07-06 16:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:48:17 UTC to 2016-07-06 16:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:08:17 UTC to 2016-07-06 17:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:28:17 UTC to 2016-07-06 17:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:48:17 UTC to 2016-07-06 17:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:08:17 UTC to 2016-07-06 18:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than 15.0, during the time period from 2016-07-06 18:15:00 UTC to 2016-07-06 18:50:00 UTC flagged bad (spike of bad data across all depths) Data with values less than False, during the time period from 2016-07-06 18:28:17 UTC to 2016-07-06 18:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:48:17 UTC to 2016-07-06 18:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:08:17 UTC to 2016-07-06 19:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:28:17 UTC to 2016-07-06 19:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:48:17 UTC to 2016-07-06 19:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:08:17 UTC to 2016-07-06 20:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:28:17 UTC to 2016-07-06 20:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:48:17 UTC to 2016-07-06 20:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 21:08:17 UTC to 2016-07-06 21:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:02:35 UTC to 2016-07-09 00:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:12:35 UTC to 2016-07-09 00:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:32:35 UTC to 2016-07-09 00:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:52:35 UTC to 2016-07-09 00:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:12:35 UTC to 2016-07-09 01:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:32:35 UTC to 2016-07-09 01:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:52:35 UTC to 2016-07-09 01:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 02:32:35 UTC to 2016-07-09 02:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 02:52:35 UTC to 2016-07-09 02:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:12:35 UTC to 2016-07-09 03:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:32:35 UTC to 2016-07-09 03:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:52:35 UTC to 2016-07-09 03:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:12:35 UTC to 2016-07-09 04:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:32:35 UTC to 2016-07-09 04:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:52:35 UTC to 2016-07-09 04:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:12:35 UTC to 2016-07-09 05:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:32:34 UTC to 2016-07-09 05:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:52:35 UTC to 2016-07-09 05:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:12:35 UTC to 2016-07-09 06:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:32:34 UTC to 2016-07-09 06:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:52:34 UTC to 2016-07-09 06:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:12:34 UTC to 2016-07-09 07:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:32:34 UTC to 2016-07-09 07:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:52:34 UTC to 2016-07-09 07:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:12:34 UTC to 2016-07-09 08:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:32:34 UTC to 2016-07-09 08:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:52:34 UTC to 2016-07-09 08:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:12:34 UTC to 2016-07-09 09:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:32:34 UTC to 2016-07-09 09:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:52:34 UTC to 2016-07-09 09:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:12:34 UTC to 2016-07-09 10:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:32:34 UTC to 2016-07-09 10:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:52:34 UTC to 2016-07-09 10:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:12:34 UTC to 2016-07-09 11:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:32:34 UTC to 2016-07-09 11:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:52:34 UTC to 2016-07-09 11:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:12:34 UTC to 2016-07-09 12:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:32:34 UTC to 2016-07-09 12:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:52:34 UTC to 2016-07-09 12:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:12:34 UTC to 2016-07-09 13:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:32:34 UTC to 2016-07-09 13:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:52:34 UTC to 2016-07-09 13:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:12:34 UTC to 2016-07-09 14:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:32:34 UTC to 2016-07-09 14:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:52:34 UTC to 2016-07-09 14:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:12:34 UTC to 2016-07-09 15:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:32:34 UTC to 2016-07-09 15:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:52:34 UTC to 2016-07-09 15:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:12:34 UTC to 2016-07-09 16:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:32:34 UTC to 2016-07-09 16:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:52:34 UTC to 2016-07-09 16:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:12:34 UTC to 2016-07-09 17:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:32:34 UTC to 2016-07-09 17:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:52:34 UTC to 2016-07-09 17:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:12:34 UTC to 2016-07-09 18:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:32:34 UTC to 2016-07-09 18:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:52:34 UTC to 2016-07-09 18:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:12:34 UTC to 2016-07-09 19:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:32:34 UTC to 2016-07-09 19:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:52:34 UTC to 2016-07-09 19:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:12:34 UTC to 2016-07-09 20:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:32:34 UTC to 2016-07-09 20:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:52:34 UTC to 2016-07-09 20:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:12:34 UTC to 2016-07-09 21:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:32:34 UTC to 2016-07-09 21:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:52:34 UTC to 2016-07-09 21:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:12:34 UTC to 2016-07-09 22:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:32:34 UTC to 2016-07-09 22:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:52:34 UTC to 2016-07-09 22:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 23:12:34 UTC to 2016-07-09 23:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 23:32:34 UTC to 2016-07-09 23:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 01:53:30 UTC to 2016-07-11 01:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:13:30 UTC to 2016-07-11 02:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:33:30 UTC to 2016-07-11 02:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:53:30 UTC to 2016-07-11 02:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:13:30 UTC to 2016-07-11 03:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:33:30 UTC to 2016-07-11 03:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:53:30 UTC to 2016-07-11 03:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:13:30 UTC to 2016-07-11 04:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:33:30 UTC to 2016-07-11 04:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:53:30 UTC to 2016-07-11 04:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:13:30 UTC to 2016-07-11 05:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:33:30 UTC to 2016-07-11 05:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:53:30 UTC to 2016-07-11 05:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:13:30 UTC to 2016-07-11 06:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:33:30 UTC to 2016-07-11 06:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:53:30 UTC to 2016-07-11 06:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:13:30 UTC to 2016-07-11 07:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:33:30 UTC to 2016-07-11 07:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:53:30 UTC to 2016-07-11 07:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:13:29 UTC to 2016-07-11 08:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:33:30 UTC to 2016-07-11 08:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:53:30 UTC to 2016-07-11 08:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:13:30 UTC to 2016-07-11 09:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:33:29 UTC to 2016-07-11 09:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:53:29 UTC to 2016-07-11 09:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:13:30 UTC to 2016-07-11 10:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:33:29 UTC to 2016-07-11 10:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:53:30 UTC to 2016-07-11 10:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:13:29 UTC to 2016-07-11 11:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:33:29 UTC to 2016-07-11 11:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:53:29 UTC to 2016-07-11 11:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:13:29 UTC to 2016-07-11 12:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:33:29 UTC to 2016-07-11 12:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:53:29 UTC to 2016-07-11 12:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:13:29 UTC to 2016-07-11 13:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:33:29 UTC to 2016-07-11 13:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:53:29 UTC to 2016-07-11 13:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:13:29 UTC to 2016-07-11 14:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:33:29 UTC to 2016-07-11 14:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:53:29 UTC to 2016-07-11 14:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:13:29 UTC to 2016-07-11 15:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:33:29 UTC to 2016-07-11 15:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:53:30 UTC to 2016-07-11 15:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:13:30 UTC to 2016-07-11 16:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:33:29 UTC to 2016-07-11 16:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:53:29 UTC to 2016-07-11 16:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:13:29 UTC to 2016-07-11 17:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:33:29 UTC to 2016-07-11 17:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:53:29 UTC to 2016-07-11 17:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:13:29 UTC to 2016-07-11 18:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:33:29 UTC to 2016-07-11 18:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:53:29 UTC to 2016-07-11 18:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:13:29 UTC to 2016-07-11 19:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:33:30 UTC to 2016-07-11 19:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:53:29 UTC to 2016-07-11 19:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:13:29 UTC to 2016-07-11 20:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:33:29 UTC to 2016-07-11 20:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:53:29 UTC to 2016-07-11 20:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:13:29 UTC to 2016-07-11 21:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:33:29 UTC to 2016-07-11 21:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:53:29 UTC to 2016-07-11 21:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:13:29 UTC to 2016-07-11 22:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:33:29 UTC to 2016-07-11 22:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:53:29 UTC to 2016-07-11 22:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:13:29 UTC to 2016-07-11 23:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:33:29 UTC to 2016-07-11 23:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:53:29 UTC to 2016-07-11 23:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:13:29 UTC to 2016-07-12 00:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:33:29 UTC to 2016-07-12 00:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:53:29 UTC to 2016-07-12 00:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:13:29 UTC to 2016-07-12 01:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:33:29 UTC to 2016-07-12 01:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:53:29 UTC to 2016-07-12 01:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:13:29 UTC to 2016-07-12 02:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:33:29 UTC to 2016-07-12 02:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:53:29 UTC to 2016-07-12 02:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:13:29 UTC to 2016-07-12 03:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:33:29 UTC to 2016-07-12 03:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:53:29 UTC to 2016-07-12 03:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:13:29 UTC to 2016-07-12 04:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:33:29 UTC to 2016-07-12 04:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:53:29 UTC to 2016-07-12 04:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:13:29 UTC to 2016-07-12 05:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:33:29 UTC to 2016-07-12 05:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:53:29 UTC to 2016-07-12 05:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:13:29 UTC to 2016-07-12 06:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:33:29 UTC to 2016-07-12 06:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:53:29 UTC to 2016-07-12 06:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:13:29 UTC to 2016-07-12 07:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:33:29 UTC to 2016-07-12 07:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:53:29 UTC to 2016-07-12 07:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:13:29 UTC to 2016-07-12 08:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:33:29 UTC to 2016-07-12 08:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:53:29 UTC to 2016-07-12 08:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:13:29 UTC to 2016-07-12 09:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:33:29 UTC to 2016-07-12 09:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:53:29 UTC to 2016-07-12 09:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 10:13:29 UTC to 2016-07-12 10:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:09:27 UTC to 2016-07-13 18:09:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:19:28 UTC to 2016-07-13 18:19:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:39:28 UTC to 2016-07-13 18:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:59:28 UTC to 2016-07-13 18:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:19:27 UTC to 2016-07-13 19:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:39:28 UTC to 2016-07-13 19:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:59:28 UTC to 2016-07-13 19:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:19:27 UTC to 2016-07-13 20:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:39:28 UTC to 2016-07-13 20:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:59:27 UTC to 2016-07-13 20:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:19:27 UTC to 2016-07-13 21:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:39:27 UTC to 2016-07-13 21:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:59:27 UTC to 2016-07-13 21:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:19:27 UTC to 2016-07-13 22:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:39:27 UTC to 2016-07-13 22:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:59:27 UTC to 2016-07-13 22:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:19:27 UTC to 2016-07-13 23:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:39:27 UTC to 2016-07-13 23:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:59:28 UTC to 2016-07-13 23:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 00:19:27 UTC to 2016-07-14 00:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 00:59:27 UTC to 2016-07-14 00:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:19:27 UTC to 2016-07-14 01:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:39:27 UTC to 2016-07-14 01:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:59:27 UTC to 2016-07-14 01:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:19:27 UTC to 2016-07-14 02:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:39:27 UTC to 2016-07-14 02:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:59:27 UTC to 2016-07-14 02:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:19:27 UTC to 2016-07-14 03:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:39:27 UTC to 2016-07-14 03:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:59:27 UTC to 2016-07-14 03:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:19:27 UTC to 2016-07-14 04:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:39:27 UTC to 2016-07-14 04:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:59:27 UTC to 2016-07-14 04:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:19:27 UTC to 2016-07-14 05:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:39:27 UTC to 2016-07-14 05:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:59:27 UTC to 2016-07-14 05:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:19:27 UTC to 2016-07-14 06:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:39:27 UTC to 2016-07-14 06:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:59:27 UTC to 2016-07-14 06:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:19:27 UTC to 2016-07-14 07:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:39:27 UTC to 2016-07-14 07:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:59:27 UTC to 2016-07-14 07:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:19:27 UTC to 2016-07-14 08:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:39:27 UTC to 2016-07-14 08:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:59:27 UTC to 2016-07-14 08:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:19:27 UTC to 2016-07-14 09:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:39:27 UTC to 2016-07-14 09:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:59:27 UTC to 2016-07-14 09:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:19:27 UTC to 2016-07-14 10:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:39:27 UTC to 2016-07-14 10:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:59:27 UTC to 2016-07-14 10:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:19:27 UTC to 2016-07-14 11:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:39:27 UTC to 2016-07-14 11:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:59:27 UTC to 2016-07-14 11:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:19:27 UTC to 2016-07-14 12:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:39:27 UTC to 2016-07-14 12:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:59:27 UTC to 2016-07-14 12:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:19:27 UTC to 2016-07-14 13:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:39:27 UTC to 2016-07-14 13:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:59:27 UTC to 2016-07-14 13:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:19:27 UTC to 2016-07-14 14:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:39:27 UTC to 2016-07-14 14:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:59:27 UTC to 2016-07-14 14:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:19:27 UTC to 2016-07-14 15:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:39:27 UTC to 2016-07-14 15:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:59:27 UTC to 2016-07-14 15:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:19:27 UTC to 2016-07-14 16:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:39:27 UTC to 2016-07-14 16:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:59:27 UTC to 2016-07-14 16:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:19:27 UTC to 2016-07-14 17:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:39:27 UTC to 2016-07-14 17:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:59:27 UTC to 2016-07-14 17:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:19:27 UTC to 2016-07-14 18:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:39:27 UTC to 2016-07-14 18:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:59:27 UTC to 2016-07-14 18:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:19:27 UTC to 2016-07-14 19:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:39:26 UTC to 2016-07-14 19:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:59:27 UTC to 2016-07-14 19:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:19:27 UTC to 2016-07-14 20:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:39:26 UTC to 2016-07-14 20:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:59:27 UTC to 2016-07-14 20:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:19:26 UTC to 2016-07-14 21:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:39:26 UTC to 2016-07-14 21:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:59:26 UTC to 2016-07-14 21:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:19:26 UTC to 2016-07-14 22:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:39:26 UTC to 2016-07-14 22:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:59:27 UTC to 2016-07-14 22:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:19:26 UTC to 2016-07-14 23:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:39:26 UTC to 2016-07-14 23:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:59:26 UTC to 2016-07-14 23:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:19:26 UTC to 2016-07-15 00:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:39:26 UTC to 2016-07-15 00:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:59:27 UTC to 2016-07-15 00:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 01:19:27 UTC to 2016-07-15 01:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 01:59:26 UTC to 2016-07-15 01:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:19:26 UTC to 2016-07-15 02:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:39:26 UTC to 2016-07-15 02:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:59:26 UTC to 2016-07-15 02:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:19:26 UTC to 2016-07-15 03:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:39:26 UTC to 2016-07-15 03:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:59:26 UTC to 2016-07-15 03:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:19:26 UTC to 2016-07-15 04:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:39:26 UTC to 2016-07-15 04:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:59:26 UTC to 2016-07-15 04:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 05:19:26 UTC to 2016-07-15 05:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 05:39:26 UTC to 2016-07-15 05:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:19:26 UTC to 2016-07-15 06:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:39:26 UTC to 2016-07-15 06:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:59:26 UTC to 2016-07-15 06:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:19:26 UTC to 2016-07-15 07:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:39:26 UTC to 2016-07-15 07:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:59:26 UTC to 2016-07-15 07:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:19:26 UTC to 2016-07-15 08:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:39:26 UTC to 2016-07-15 08:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:59:26 UTC to 2016-07-15 08:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:19:26 UTC to 2016-07-15 09:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:39:26 UTC to 2016-07-15 09:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:59:26 UTC to 2016-07-15 09:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:19:26 UTC to 2016-07-15 10:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:39:26 UTC to 2016-07-15 10:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:59:26 UTC to 2016-07-15 10:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:19:26 UTC to 2016-07-15 11:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:39:26 UTC to 2016-07-15 11:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:59:26 UTC to 2016-07-15 11:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 19:39:26 UTC to 2016-07-15 19:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 19:59:26 UTC to 2016-07-15 19:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:19:26 UTC to 2016-07-15 20:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:39:26 UTC to 2016-07-15 20:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:59:26 UTC to 2016-07-15 20:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:19:26 UTC to 2016-07-15 21:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:39:26 UTC to 2016-07-15 21:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:59:26 UTC to 2016-07-15 21:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:19:26 UTC to 2016-07-15 22:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:39:25 UTC to 2016-07-15 22:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:59:25 UTC to 2016-07-15 22:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:19:25 UTC to 2016-07-15 23:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:39:25 UTC to 2016-07-15 23:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:59:25 UTC to 2016-07-15 23:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:19:25 UTC to 2016-07-16 00:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:39:25 UTC to 2016-07-16 00:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:59:25 UTC to 2016-07-16 00:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:19:25 UTC to 2016-07-16 01:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:39:25 UTC to 2016-07-16 01:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:59:25 UTC to 2016-07-16 01:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 02:19:25 UTC to 2016-07-16 02:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 02:39:25 UTC to 2016-07-16 02:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:26:55 UTC to 2016-07-17 16:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:36:55 UTC to 2016-07-17 16:37:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:46:55 UTC to 2016-07-17 16:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:06:55 UTC to 2016-07-17 17:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:26:55 UTC to 2016-07-17 17:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:46:55 UTC to 2016-07-17 17:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:06:55 UTC to 2016-07-17 18:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:26:55 UTC to 2016-07-17 18:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:46:55 UTC to 2016-07-17 18:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:06:55 UTC to 2016-07-17 19:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:26:55 UTC to 2016-07-17 19:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:46:55 UTC to 2016-07-17 19:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:06:55 UTC to 2016-07-17 20:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:26:55 UTC to 2016-07-17 20:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:46:55 UTC to 2016-07-17 20:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:06:55 UTC to 2016-07-17 21:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:26:55 UTC to 2016-07-17 21:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:46:55 UTC to 2016-07-17 21:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:06:55 UTC to 2016-07-17 22:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:26:55 UTC to 2016-07-17 22:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:46:55 UTC to 2016-07-17 22:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:06:55 UTC to 2016-07-17 23:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:26:55 UTC to 2016-07-17 23:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:46:55 UTC to 2016-07-17 23:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:06:55 UTC to 2016-07-18 00:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:26:55 UTC to 2016-07-18 00:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:46:54 UTC to 2016-07-18 00:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:06:55 UTC to 2016-07-18 01:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:26:55 UTC to 2016-07-18 01:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:46:54 UTC to 2016-07-18 01:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:06:54 UTC to 2016-07-18 02:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:26:54 UTC to 2016-07-18 02:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:46:55 UTC to 2016-07-18 02:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:06:54 UTC to 2016-07-18 03:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:26:54 UTC to 2016-07-18 03:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:46:54 UTC to 2016-07-18 03:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:06:54 UTC to 2016-07-18 04:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:26:54 UTC to 2016-07-18 04:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:46:54 UTC to 2016-07-18 04:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:06:54 UTC to 2016-07-18 05:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:26:54 UTC to 2016-07-18 05:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:46:54 UTC to 2016-07-18 05:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:06:54 UTC to 2016-07-18 06:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:26:54 UTC to 2016-07-18 06:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:46:54 UTC to 2016-07-18 06:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:06:54 UTC to 2016-07-18 07:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:26:54 UTC to 2016-07-18 07:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:46:54 UTC to 2016-07-18 07:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:06:54 UTC to 2016-07-18 08:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:26:54 UTC to 2016-07-18 08:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:46:54 UTC to 2016-07-18 08:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:06:54 UTC to 2016-07-18 09:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:26:54 UTC to 2016-07-18 09:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:46:54 UTC to 2016-07-18 09:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:06:54 UTC to 2016-07-18 10:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:26:54 UTC to 2016-07-18 10:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:46:54 UTC to 2016-07-18 10:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:06:54 UTC to 2016-07-18 11:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:26:54 UTC to 2016-07-18 11:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:46:54 UTC to 2016-07-18 11:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:06:54 UTC to 2016-07-18 12:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:26:54 UTC to 2016-07-18 12:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:46:54 UTC to 2016-07-18 12:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:06:54 UTC to 2016-07-18 13:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:26:54 UTC to 2016-07-18 13:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:46:54 UTC to 2016-07-18 13:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:06:54 UTC to 2016-07-18 14:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:26:54 UTC to 2016-07-18 14:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:46:54 UTC to 2016-07-18 14:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:06:54 UTC to 2016-07-18 15:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:26:54 UTC to 2016-07-18 15:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:46:54 UTC to 2016-07-18 15:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:06:54 UTC to 2016-07-18 16:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:26:54 UTC to 2016-07-18 16:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:46:54 UTC to 2016-07-18 16:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:06:54 UTC to 2016-07-18 17:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:26:54 UTC to 2016-07-18 17:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:46:54 UTC to 2016-07-18 17:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:06:54 UTC to 2016-07-18 18:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:26:54 UTC to 2016-07-18 18:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:46:54 UTC to 2016-07-18 18:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:06:54 UTC to 2016-07-18 19:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:26:54 UTC to 2016-07-18 19:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:46:54 UTC to 2016-07-18 19:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:06:54 UTC to 2016-07-18 20:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:26:54 UTC to 2016-07-18 20:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:46:54 UTC to 2016-07-18 20:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:06:54 UTC to 2016-07-18 21:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:26:54 UTC to 2016-07-18 21:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:46:54 UTC to 2016-07-18 21:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:06:54 UTC to 2016-07-18 22:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:26:54 UTC to 2016-07-18 22:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:46:54 UTC to 2016-07-18 22:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:06:54 UTC to 2016-07-18 23:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:26:54 UTC to 2016-07-18 23:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:46:54 UTC to 2016-07-18 23:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:06:54 UTC to 2016-07-19 00:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:26:54 UTC to 2016-07-19 00:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:46:54 UTC to 2016-07-19 00:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:06:54 UTC to 2016-07-19 01:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:26:54 UTC to 2016-07-19 01:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:46:54 UTC to 2016-07-19 01:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:06:54 UTC to 2016-07-19 02:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:26:54 UTC to 2016-07-19 02:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:46:54 UTC to 2016-07-19 02:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:06:54 UTC to 2016-07-19 03:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:26:54 UTC to 2016-07-19 03:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:46:54 UTC to 2016-07-19 03:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:06:54 UTC to 2016-07-19 04:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:26:53 UTC to 2016-07-19 04:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:46:53 UTC to 2016-07-19 04:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:06:53 UTC to 2016-07-19 05:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:26:53 UTC to 2016-07-19 05:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:46:53 UTC to 2016-07-19 05:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:06:53 UTC to 2016-07-19 06:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:26:53 UTC to 2016-07-19 06:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:46:53 UTC to 2016-07-19 06:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:06:53 UTC to 2016-07-19 07:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:26:53 UTC to 2016-07-19 07:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:46:53 UTC to 2016-07-19 07:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 08:06:53 UTC to 2016-07-19 08:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 08:26:53 UTC to 2016-07-19 08:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 23:26:30 UTC to 2016-07-19 23:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 23:46:30 UTC to 2016-07-19 23:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:06:30 UTC to 2016-07-20 00:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:26:30 UTC to 2016-07-20 00:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:46:30 UTC to 2016-07-20 00:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:06:30 UTC to 2016-07-20 01:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:26:30 UTC to 2016-07-20 01:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:46:30 UTC to 2016-07-20 01:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:06:30 UTC to 2016-07-20 02:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:26:30 UTC to 2016-07-20 02:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:46:30 UTC to 2016-07-20 02:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:06:30 UTC to 2016-07-20 03:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:26:30 UTC to 2016-07-20 03:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:46:30 UTC to 2016-07-20 03:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:06:30 UTC to 2016-07-20 04:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:26:30 UTC to 2016-07-20 04:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:46:30 UTC to 2016-07-20 04:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:06:30 UTC to 2016-07-20 05:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:26:30 UTC to 2016-07-20 05:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:46:30 UTC to 2016-07-20 05:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:06:30 UTC to 2016-07-20 06:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:26:30 UTC to 2016-07-20 06:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:46:30 UTC to 2016-07-20 06:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:06:30 UTC to 2016-07-20 07:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:26:30 UTC to 2016-07-20 07:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:46:30 UTC to 2016-07-20 07:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:06:30 UTC to 2016-07-20 08:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:26:30 UTC to 2016-07-20 08:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:46:30 UTC to 2016-07-20 08:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:06:30 UTC to 2016-07-20 09:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:26:30 UTC to 2016-07-20 09:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:46:30 UTC to 2016-07-20 09:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:06:30 UTC to 2016-07-20 10:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:26:29 UTC to 2016-07-20 10:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:46:30 UTC to 2016-07-20 10:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:06:30 UTC to 2016-07-20 11:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:26:29 UTC to 2016-07-20 11:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:46:29 UTC to 2016-07-20 11:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:06:30 UTC to 2016-07-20 12:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:26:29 UTC to 2016-07-20 12:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:46:29 UTC to 2016-07-20 12:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:06:29 UTC to 2016-07-20 13:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:26:29 UTC to 2016-07-20 13:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:46:29 UTC to 2016-07-20 13:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:06:29 UTC to 2016-07-20 14:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:26:29 UTC to 2016-07-20 14:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:46:29 UTC to 2016-07-20 14:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:06:29 UTC to 2016-07-20 15:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:26:29 UTC to 2016-07-20 15:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:46:29 UTC to 2016-07-20 15:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:06:29 UTC to 2016-07-20 16:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:26:29 UTC to 2016-07-20 16:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:46:29 UTC to 2016-07-20 16:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:06:29 UTC to 2016-07-20 17:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:26:29 UTC to 2016-07-20 17:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:46:29 UTC to 2016-07-20 17:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:06:29 UTC to 2016-07-20 18:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:26:29 UTC to 2016-07-20 18:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:46:29 UTC to 2016-07-20 18:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:06:29 UTC to 2016-07-20 19:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:26:29 UTC to 2016-07-20 19:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:46:29 UTC to 2016-07-20 19:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:06:29 UTC to 2016-07-20 20:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:26:29 UTC to 2016-07-20 20:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:46:29 UTC to 2016-07-20 20:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:06:29 UTC to 2016-07-20 21:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:26:29 UTC to 2016-07-20 21:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:46:29 UTC to 2016-07-20 21:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:06:29 UTC to 2016-07-20 22:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:26:29 UTC to 2016-07-20 22:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:46:29 UTC to 2016-07-20 22:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:06:29 UTC to 2016-07-20 23:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:26:29 UTC to 2016-07-20 23:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:46:29 UTC to 2016-07-20 23:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:06:29 UTC to 2016-07-21 00:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:26:29 UTC to 2016-07-21 00:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:46:29 UTC to 2016-07-21 00:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:06:29 UTC to 2016-07-21 01:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:26:29 UTC to 2016-07-21 01:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:46:29 UTC to 2016-07-21 01:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:06:29 UTC to 2016-07-21 02:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:26:29 UTC to 2016-07-21 02:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:46:29 UTC to 2016-07-21 02:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:06:29 UTC to 2016-07-21 03:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:26:29 UTC to 2016-07-21 03:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:46:29 UTC to 2016-07-21 03:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:06:29 UTC to 2016-07-21 04:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:26:29 UTC to 2016-07-21 04:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:46:29 UTC to 2016-07-21 04:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:06:29 UTC to 2016-07-21 05:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:26:29 UTC to 2016-07-21 05:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:46:29 UTC to 2016-07-21 05:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:06:29 UTC to 2016-07-21 06:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:26:29 UTC to 2016-07-21 06:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:46:29 UTC to 2016-07-21 06:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:06:29 UTC to 2016-07-21 07:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:26:29 UTC to 2016-07-21 07:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:46:29 UTC to 2016-07-21 07:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:06:29 UTC to 2016-07-21 08:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:26:29 UTC to 2016-07-21 08:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:46:29 UTC to 2016-07-21 08:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:06:29 UTC to 2016-07-21 09:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:26:29 UTC to 2016-07-21 09:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:46:29 UTC to 2016-07-21 09:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:06:29 UTC to 2016-07-21 10:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:26:29 UTC to 2016-07-21 10:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:46:29 UTC to 2016-07-21 10:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:06:29 UTC to 2016-07-21 11:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:26:29 UTC to 2016-07-21 11:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:46:29 UTC to 2016-07-21 11:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:06:29 UTC to 2016-07-21 12:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:26:29 UTC to 2016-07-21 12:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:46:28 UTC to 2016-07-21 12:46:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:05:48 UTC to 2016-07-22 17:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:25:48 UTC to 2016-07-22 17:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:45:48 UTC to 2016-07-22 17:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:05:48 UTC to 2016-07-22 18:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:25:48 UTC to 2016-07-22 18:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:45:48 UTC to 2016-07-22 18:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:05:48 UTC to 2016-07-22 19:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:25:48 UTC to 2016-07-22 19:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:45:48 UTC to 2016-07-22 19:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:05:48 UTC to 2016-07-22 20:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:25:48 UTC to 2016-07-22 20:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:45:48 UTC to 2016-07-22 20:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:05:48 UTC to 2016-07-22 21:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:25:48 UTC to 2016-07-22 21:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:45:48 UTC to 2016-07-22 21:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:05:48 UTC to 2016-07-22 22:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:25:48 UTC to 2016-07-22 22:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:45:48 UTC to 2016-07-22 22:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:05:48 UTC to 2016-07-22 23:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:25:48 UTC to 2016-07-22 23:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:45:48 UTC to 2016-07-22 23:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:05:48 UTC to 2016-07-23 00:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:25:48 UTC to 2016-07-23 00:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:45:48 UTC to 2016-07-23 00:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:05:47 UTC to 2016-07-23 01:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:25:47 UTC to 2016-07-23 01:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:45:47 UTC to 2016-07-23 01:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:05:47 UTC to 2016-07-23 02:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:25:47 UTC to 2016-07-23 02:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:45:47 UTC to 2016-07-23 02:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:05:47 UTC to 2016-07-23 03:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:25:47 UTC to 2016-07-23 03:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:45:47 UTC to 2016-07-23 03:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:05:47 UTC to 2016-07-23 04:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:25:47 UTC to 2016-07-23 04:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:45:47 UTC to 2016-07-23 04:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:05:47 UTC to 2016-07-23 05:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:25:47 UTC to 2016-07-23 05:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:45:47 UTC to 2016-07-23 05:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:05:47 UTC to 2016-07-23 06:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:25:47 UTC to 2016-07-23 06:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:45:47 UTC to 2016-07-23 06:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:05:47 UTC to 2016-07-23 07:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:25:47 UTC to 2016-07-23 07:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:45:47 UTC to 2016-07-23 07:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:05:47 UTC to 2016-07-23 08:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:25:47 UTC to 2016-07-23 08:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:45:47 UTC to 2016-07-23 08:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:05:47 UTC to 2016-07-23 09:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:25:47 UTC to 2016-07-23 09:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:45:47 UTC to 2016-07-23 09:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:05:47 UTC to 2016-07-23 10:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:25:47 UTC to 2016-07-23 10:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:45:47 UTC to 2016-07-23 10:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:05:47 UTC to 2016-07-23 11:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:25:47 UTC to 2016-07-23 11:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:45:47 UTC to 2016-07-23 11:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:05:47 UTC to 2016-07-23 12:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:25:47 UTC to 2016-07-23 12:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:45:47 UTC to 2016-07-23 12:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:05:47 UTC to 2016-07-23 13:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:25:47 UTC to 2016-07-23 13:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:45:47 UTC to 2016-07-23 13:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:05:47 UTC to 2016-07-23 14:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:25:47 UTC to 2016-07-23 14:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:45:47 UTC to 2016-07-23 14:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:05:47 UTC to 2016-07-23 15:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:25:47 UTC to 2016-07-23 15:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:45:47 UTC to 2016-07-23 15:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:05:47 UTC to 2016-07-23 16:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:25:47 UTC to 2016-07-23 16:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:45:47 UTC to 2016-07-23 16:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:05:47 UTC to 2016-07-23 17:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:25:47 UTC to 2016-07-23 17:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:45:47 UTC to 2016-07-23 17:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:05:47 UTC to 2016-07-23 18:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:25:47 UTC to 2016-07-23 18:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:45:47 UTC to 2016-07-23 18:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:05:47 UTC to 2016-07-23 19:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:25:47 UTC to 2016-07-23 19:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:45:47 UTC to 2016-07-23 19:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:05:47 UTC to 2016-07-23 20:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:25:47 UTC to 2016-07-23 20:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:45:47 UTC to 2016-07-23 20:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:05:47 UTC to 2016-07-23 21:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:25:47 UTC to 2016-07-23 21:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:45:47 UTC to 2016-07-23 21:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:05:47 UTC to 2016-07-23 22:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:25:47 UTC to 2016-07-23 22:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:45:47 UTC to 2016-07-23 22:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:05:47 UTC to 2016-07-23 23:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:25:47 UTC to 2016-07-23 23:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:45:47 UTC to 2016-07-23 23:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:05:47 UTC to 2016-07-24 00:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:25:47 UTC to 2016-07-24 00:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:45:47 UTC to 2016-07-24 00:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:05:47 UTC to 2016-07-24 01:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:25:47 UTC to 2016-07-24 01:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:45:47 UTC to 2016-07-24 01:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:05:47 UTC to 2016-07-24 02:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:25:47 UTC to 2016-07-24 02:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:45:47 UTC to 2016-07-24 02:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:05:46 UTC to 2016-07-24 03:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:25:47 UTC to 2016-07-24 03:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:45:46 UTC to 2016-07-24 03:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:05:46 UTC to 2016-07-24 04:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:25:46 UTC to 2016-07-24 04:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:45:46 UTC to 2016-07-24 04:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:05:46 UTC to 2016-07-24 05:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:25:46 UTC to 2016-07-24 05:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:45:46 UTC to 2016-07-24 05:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:05:46 UTC to 2016-07-24 06:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:25:46 UTC to 2016-07-24 06:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:45:46 UTC to 2016-07-24 06:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:05:46 UTC to 2016-07-24 07:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:25:46 UTC to 2016-07-24 07:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:45:46 UTC to 2016-07-24 07:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:05:46 UTC to 2016-07-24 08:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:25:46 UTC to 2016-07-24 08:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:45:46 UTC to 2016-07-24 08:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:05:46 UTC to 2016-07-24 09:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:25:46 UTC to 2016-07-24 09:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:45:46 UTC to 2016-07-24 09:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:05:46 UTC to 2016-07-24 10:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:25:46 UTC to 2016-07-24 10:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:45:46 UTC to 2016-07-24 10:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 11:05:46 UTC to 2016-07-24 11:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 11:25:46 UTC to 2016-07-24 11:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 00:50:03 UTC to 2016-07-25 00:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:00:03 UTC to 2016-07-25 01:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:20:03 UTC to 2016-07-25 01:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:40:03 UTC to 2016-07-25 01:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:00:03 UTC to 2016-07-25 02:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:20:03 UTC to 2016-07-25 02:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:40:03 UTC to 2016-07-25 02:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:00:03 UTC to 2016-07-25 03:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:20:03 UTC to 2016-07-25 03:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:40:03 UTC to 2016-07-25 03:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:00:03 UTC to 2016-07-25 04:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:20:03 UTC to 2016-07-25 04:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:40:03 UTC to 2016-07-25 04:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:00:03 UTC to 2016-07-25 05:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:20:03 UTC to 2016-07-25 05:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:40:03 UTC to 2016-07-25 05:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:00:03 UTC to 2016-07-25 06:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:20:03 UTC to 2016-07-25 06:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:40:03 UTC to 2016-07-25 06:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:00:03 UTC to 2016-07-25 07:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:20:03 UTC to 2016-07-25 07:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:40:03 UTC to 2016-07-25 07:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:00:03 UTC to 2016-07-25 08:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:20:03 UTC to 2016-07-25 08:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:40:03 UTC to 2016-07-25 08:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:00:03 UTC to 2016-07-25 09:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:20:03 UTC to 2016-07-25 09:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:40:03 UTC to 2016-07-25 09:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:00:03 UTC to 2016-07-25 10:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:20:03 UTC to 2016-07-25 10:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:40:03 UTC to 2016-07-25 10:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:00:02 UTC to 2016-07-25 11:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:20:02 UTC to 2016-07-25 11:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:40:03 UTC to 2016-07-25 11:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:00:02 UTC to 2016-07-25 12:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:20:02 UTC to 2016-07-25 12:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:40:02 UTC to 2016-07-25 12:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:00:02 UTC to 2016-07-25 13:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:20:02 UTC to 2016-07-25 13:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:40:02 UTC to 2016-07-25 13:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:00:02 UTC to 2016-07-25 14:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:20:02 UTC to 2016-07-25 14:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:40:02 UTC to 2016-07-25 14:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:00:02 UTC to 2016-07-25 15:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:20:02 UTC to 2016-07-25 15:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:40:02 UTC to 2016-07-25 15:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:00:02 UTC to 2016-07-25 16:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:20:02 UTC to 2016-07-25 16:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:40:02 UTC to 2016-07-25 16:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:00:02 UTC to 2016-07-25 17:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:20:02 UTC to 2016-07-25 17:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:40:02 UTC to 2016-07-25 17:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:00:02 UTC to 2016-07-25 18:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:20:02 UTC to 2016-07-25 18:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:40:02 UTC to 2016-07-25 18:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:00:02 UTC to 2016-07-25 19:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:20:02 UTC to 2016-07-25 19:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:40:02 UTC to 2016-07-25 19:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:00:02 UTC to 2016-07-25 20:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:20:02 UTC to 2016-07-25 20:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:40:02 UTC to 2016-07-25 20:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:00:02 UTC to 2016-07-25 21:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:20:02 UTC to 2016-07-25 21:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:40:02 UTC to 2016-07-25 21:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:00:02 UTC to 2016-07-25 22:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:20:02 UTC to 2016-07-25 22:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:40:02 UTC to 2016-07-25 22:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:00:02 UTC to 2016-07-25 23:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:20:02 UTC to 2016-07-25 23:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:40:02 UTC to 2016-07-25 23:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:00:02 UTC to 2016-07-26 00:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:20:02 UTC to 2016-07-26 00:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:40:02 UTC to 2016-07-26 00:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:00:02 UTC to 2016-07-26 01:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:20:02 UTC to 2016-07-26 01:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:40:02 UTC to 2016-07-26 01:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:00:02 UTC to 2016-07-26 02:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:20:02 UTC to 2016-07-26 02:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:40:02 UTC to 2016-07-26 02:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:00:02 UTC to 2016-07-26 03:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:20:02 UTC to 2016-07-26 03:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:40:02 UTC to 2016-07-26 03:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:00:02 UTC to 2016-07-26 04:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:20:02 UTC to 2016-07-26 04:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:40:02 UTC to 2016-07-26 04:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:00:02 UTC to 2016-07-26 05:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:20:02 UTC to 2016-07-26 05:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:40:02 UTC to 2016-07-26 05:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:00:02 UTC to 2016-07-26 06:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:20:02 UTC to 2016-07-26 06:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:40:02 UTC to 2016-07-26 06:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 07:00:02 UTC to 2016-07-26 07:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 07:20:02 UTC to 2016-07-26 07:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 15:37:03 UTC to 2016-07-28 15:37:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 15:47:03 UTC to 2016-07-28 15:47:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:07:03 UTC to 2016-07-28 16:07:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:27:03 UTC to 2016-07-28 16:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:47:02 UTC to 2016-07-28 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:07:02 UTC to 2016-07-28 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:27:02 UTC to 2016-07-28 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:47:02 UTC to 2016-07-28 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:07:02 UTC to 2016-07-28 18:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:27:03 UTC to 2016-07-28 18:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:47:02 UTC to 2016-07-28 18:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:07:02 UTC to 2016-07-28 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:27:02 UTC to 2016-07-28 19:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:47:02 UTC to 2016-07-28 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:07:02 UTC to 2016-07-28 20:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:27:02 UTC to 2016-07-28 20:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:47:02 UTC to 2016-07-28 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:07:02 UTC to 2016-07-28 21:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:27:02 UTC to 2016-07-28 21:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:47:02 UTC to 2016-07-28 21:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:07:02 UTC to 2016-07-28 22:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:27:03 UTC to 2016-07-28 22:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:47:02 UTC to 2016-07-28 22:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:07:02 UTC to 2016-07-28 23:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:27:02 UTC to 2016-07-28 23:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:47:02 UTC to 2016-07-28 23:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:07:02 UTC to 2016-07-29 00:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:27:02 UTC to 2016-07-29 00:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:47:02 UTC to 2016-07-29 00:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:07:02 UTC to 2016-07-29 01:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:27:02 UTC to 2016-07-29 01:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:47:03 UTC to 2016-07-29 01:47:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:07:02 UTC to 2016-07-29 02:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:27:02 UTC to 2016-07-29 02:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:47:02 UTC to 2016-07-29 02:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:07:02 UTC to 2016-07-29 03:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:27:02 UTC to 2016-07-29 03:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:47:02 UTC to 2016-07-29 03:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:07:02 UTC to 2016-07-29 04:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:27:02 UTC to 2016-07-29 04:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:47:02 UTC to 2016-07-29 04:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:07:02 UTC to 2016-07-29 05:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:27:02 UTC to 2016-07-29 05:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:47:02 UTC to 2016-07-29 05:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:07:02 UTC to 2016-07-29 06:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:27:02 UTC to 2016-07-29 06:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:47:02 UTC to 2016-07-29 06:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:07:02 UTC to 2016-07-29 07:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:27:02 UTC to 2016-07-29 07:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:47:02 UTC to 2016-07-29 07:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:07:02 UTC to 2016-07-29 08:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:27:02 UTC to 2016-07-29 08:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:47:02 UTC to 2016-07-29 08:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:07:02 UTC to 2016-07-29 09:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:27:02 UTC to 2016-07-29 09:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:47:02 UTC to 2016-07-29 09:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:07:02 UTC to 2016-07-29 10:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:27:02 UTC to 2016-07-29 10:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:47:02 UTC to 2016-07-29 10:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:07:02 UTC to 2016-07-29 11:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:27:02 UTC to 2016-07-29 11:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:47:02 UTC to 2016-07-29 11:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:07:02 UTC to 2016-07-29 12:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:27:02 UTC to 2016-07-29 12:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:47:02 UTC to 2016-07-29 12:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:07:02 UTC to 2016-07-29 13:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:27:02 UTC to 2016-07-29 13:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:47:02 UTC to 2016-07-29 13:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:07:02 UTC to 2016-07-29 14:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:27:02 UTC to 2016-07-29 14:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:47:02 UTC to 2016-07-29 14:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:07:02 UTC to 2016-07-29 15:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:27:02 UTC to 2016-07-29 15:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:47:02 UTC to 2016-07-29 15:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:07:02 UTC to 2016-07-29 16:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:27:02 UTC to 2016-07-29 16:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:47:02 UTC to 2016-07-29 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:07:02 UTC to 2016-07-29 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:27:02 UTC to 2016-07-29 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:47:02 UTC to 2016-07-29 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:07:02 UTC to 2016-07-29 18:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:27:02 UTC to 2016-07-29 18:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:47:01 UTC to 2016-07-29 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:07:02 UTC to 2016-07-29 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:27:01 UTC to 2016-07-29 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:47:02 UTC to 2016-07-29 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:07:01 UTC to 2016-07-29 20:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:27:01 UTC to 2016-07-29 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:47:02 UTC to 2016-07-29 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:07:01 UTC to 2016-07-29 21:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:27:01 UTC to 2016-07-29 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:47:01 UTC to 2016-07-29 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:07:01 UTC to 2016-07-29 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:27:02 UTC to 2016-07-29 22:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:47:01 UTC to 2016-07-29 22:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:07:01 UTC to 2016-07-29 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:27:01 UTC to 2016-07-29 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:47:01 UTC to 2016-07-29 23:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:07:01 UTC to 2016-07-30 00:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:27:01 UTC to 2016-07-30 00:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:47:01 UTC to 2016-07-30 00:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:07:01 UTC to 2016-07-30 01:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:27:01 UTC to 2016-07-30 01:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:47:01 UTC to 2016-07-30 01:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:07:01 UTC to 2016-07-30 02:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:27:01 UTC to 2016-07-30 02:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:47:01 UTC to 2016-07-30 02:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:07:01 UTC to 2016-07-30 03:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:27:01 UTC to 2016-07-30 03:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:47:01 UTC to 2016-07-30 03:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:07:01 UTC to 2016-07-30 04:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:27:01 UTC to 2016-07-30 04:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:47:01 UTC to 2016-07-30 04:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:07:01 UTC to 2016-07-30 05:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:27:01 UTC to 2016-07-30 05:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:47:01 UTC to 2016-07-30 05:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:07:01 UTC to 2016-07-30 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:27:01 UTC to 2016-07-30 06:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:47:01 UTC to 2016-07-30 06:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:07:01 UTC to 2016-07-30 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:27:01 UTC to 2016-07-30 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:47:01 UTC to 2016-07-30 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:07:01 UTC to 2016-07-30 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:27:01 UTC to 2016-07-30 08:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:47:01 UTC to 2016-07-30 08:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:07:01 UTC to 2016-07-30 09:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:27:01 UTC to 2016-07-30 09:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:47:01 UTC to 2016-07-30 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:07:01 UTC to 2016-07-30 10:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:27:01 UTC to 2016-07-30 10:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:47:01 UTC to 2016-07-30 10:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:07:01 UTC to 2016-07-30 11:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:27:01 UTC to 2016-07-30 11:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:47:01 UTC to 2016-07-30 11:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:07:01 UTC to 2016-07-30 12:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:27:01 UTC to 2016-07-30 12:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:47:01 UTC to 2016-07-30 12:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:07:01 UTC to 2016-07-30 13:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:27:01 UTC to 2016-07-30 13:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:47:01 UTC to 2016-07-30 13:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:07:01 UTC to 2016-07-30 14:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:27:01 UTC to 2016-07-30 14:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:47:01 UTC to 2016-07-30 14:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:07:01 UTC to 2016-07-30 15:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:27:01 UTC to 2016-07-30 15:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:47:01 UTC to 2016-07-30 15:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:07:01 UTC to 2016-07-30 16:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:27:01 UTC to 2016-07-30 16:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:47:01 UTC to 2016-07-30 16:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:07:01 UTC to 2016-07-30 17:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:27:01 UTC to 2016-07-30 17:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:47:01 UTC to 2016-07-30 17:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:07:01 UTC to 2016-07-30 18:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:27:01 UTC to 2016-07-30 18:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:47:01 UTC to 2016-07-30 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:07:01 UTC to 2016-07-30 19:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:27:01 UTC to 2016-07-30 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:47:01 UTC to 2016-07-30 19:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:07:00 UTC to 2016-07-30 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:27:01 UTC to 2016-07-30 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:47:01 UTC to 2016-07-30 20:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:07:00 UTC to 2016-07-30 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:27:01 UTC to 2016-07-30 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:47:01 UTC to 2016-07-30 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:07:01 UTC to 2016-07-30 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:27:00 UTC to 2016-07-30 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:47:00 UTC to 2016-07-30 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:07:01 UTC to 2016-07-30 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:27:01 UTC to 2016-07-30 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:47:00 UTC to 2016-07-30 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:07:00 UTC to 2016-07-31 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:27:00 UTC to 2016-07-31 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:47:00 UTC to 2016-07-31 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:07:00 UTC to 2016-07-31 01:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:27:00 UTC to 2016-07-31 01:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:47:00 UTC to 2016-07-31 01:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:07:00 UTC to 2016-07-31 02:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:27:00 UTC to 2016-07-31 02:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:47:00 UTC to 2016-07-31 02:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:07:00 UTC to 2016-07-31 03:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:27:00 UTC to 2016-07-31 03:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:47:00 UTC to 2016-07-31 03:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:07:00 UTC to 2016-07-31 04:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:27:00 UTC to 2016-07-31 04:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:47:00 UTC to 2016-07-31 04:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:07:00 UTC to 2016-07-31 05:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:27:00 UTC to 2016-07-31 05:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:47:00 UTC to 2016-07-31 05:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:07:00 UTC to 2016-07-31 06:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:27:00 UTC to 2016-07-31 06:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:47:00 UTC to 2016-07-31 06:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:07:00 UTC to 2016-07-31 07:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:27:00 UTC to 2016-07-31 07:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:47:00 UTC to 2016-07-31 07:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:07:00 UTC to 2016-07-31 08:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:27:00 UTC to 2016-07-31 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:47:00 UTC to 2016-07-31 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:07:00 UTC to 2016-07-31 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:27:00 UTC to 2016-07-31 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:47:00 UTC to 2016-07-31 09:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:07:00 UTC to 2016-07-31 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:27:00 UTC to 2016-07-31 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:47:00 UTC to 2016-07-31 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:07:00 UTC to 2016-07-31 11:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:27:00 UTC to 2016-07-31 11:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:47:00 UTC to 2016-07-31 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:07:00 UTC to 2016-07-31 12:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:27:00 UTC to 2016-07-31 12:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:47:00 UTC to 2016-07-31 12:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:07:00 UTC to 2016-07-31 13:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:27:00 UTC to 2016-07-31 13:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:47:00 UTC to 2016-07-31 13:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:07:00 UTC to 2016-07-31 14:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:27:00 UTC to 2016-07-31 14:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:47:00 UTC to 2016-07-31 14:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:07:00 UTC to 2016-07-31 15:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:27:00 UTC to 2016-07-31 15:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:47:00 UTC to 2016-07-31 15:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:07:00 UTC to 2016-07-31 16:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:27:00 UTC to 2016-07-31 16:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:47:00 UTC to 2016-07-31 16:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:07:00 UTC to 2016-07-31 17:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:27:00 UTC to 2016-07-31 17:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:47:00 UTC to 2016-07-31 17:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:07:00 UTC to 2016-07-31 18:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:27:00 UTC to 2016-07-31 18:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:47:00 UTC to 2016-07-31 18:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:07:00 UTC to 2016-07-31 19:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:27:00 UTC to 2016-07-31 19:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:47:00 UTC to 2016-07-31 19:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:07:00 UTC to 2016-07-31 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:27:00 UTC to 2016-07-31 20:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:47:00 UTC to 2016-07-31 20:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:07:00 UTC to 2016-07-31 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:27:00 UTC to 2016-07-31 21:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:47:00 UTC to 2016-07-31 21:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:07:00 UTC to 2016-07-31 22:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:27:00 UTC to 2016-07-31 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:47:00 UTC to 2016-07-31 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:07:00 UTC to 2016-07-31 23:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:26:59 UTC to 2016-07-31 23:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:47:00 UTC to 2016-07-31 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:07:00 UTC to 2016-08-01 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:27:00 UTC to 2016-08-01 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:47:00 UTC to 2016-08-01 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:06:59 UTC to 2016-08-01 01:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:26:59 UTC to 2016-08-01 01:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:46:59 UTC to 2016-08-01 01:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:06:59 UTC to 2016-08-01 02:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:26:59 UTC to 2016-08-01 02:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:46:59 UTC to 2016-08-01 02:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 03:06:59 UTC to 2016-08-01 03:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 03:26:59 UTC to 2016-08-01 03:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 08:11:40 UTC to 2016-07-01 08:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 08:31:40 UTC to 2016-07-01 08:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 08:51:40 UTC to 2016-07-01 08:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:11:40 UTC to 2016-07-01 09:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:31:40 UTC to 2016-07-01 09:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 09:51:40 UTC to 2016-07-01 09:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:11:40 UTC to 2016-07-01 10:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:31:40 UTC to 2016-07-01 10:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 10:51:40 UTC to 2016-07-01 10:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:11:40 UTC to 2016-07-01 11:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:31:40 UTC to 2016-07-01 11:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 11:51:40 UTC to 2016-07-01 11:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:11:40 UTC to 2016-07-01 12:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:31:50 UTC to 2016-07-01 12:32:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 12:51:40 UTC to 2016-07-01 12:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:11:40 UTC to 2016-07-01 13:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:31:40 UTC to 2016-07-01 13:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 13:51:40 UTC to 2016-07-01 13:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:11:40 UTC to 2016-07-01 14:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:31:40 UTC to 2016-07-01 14:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 14:51:40 UTC to 2016-07-01 14:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:11:40 UTC to 2016-07-01 15:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:31:40 UTC to 2016-07-01 15:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 15:51:40 UTC to 2016-07-01 15:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:11:40 UTC to 2016-07-01 16:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:31:40 UTC to 2016-07-01 16:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 16:51:40 UTC to 2016-07-01 16:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:11:40 UTC to 2016-07-01 17:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:31:40 UTC to 2016-07-01 17:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 17:51:40 UTC to 2016-07-01 17:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:11:40 UTC to 2016-07-01 18:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:31:40 UTC to 2016-07-01 18:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 18:51:40 UTC to 2016-07-01 18:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:11:40 UTC to 2016-07-01 19:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:31:40 UTC to 2016-07-01 19:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 19:51:40 UTC to 2016-07-01 19:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:11:40 UTC to 2016-07-01 20:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:31:40 UTC to 2016-07-01 20:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 20:51:40 UTC to 2016-07-01 20:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:11:40 UTC to 2016-07-01 21:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:31:40 UTC to 2016-07-01 21:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 21:51:40 UTC to 2016-07-01 21:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:11:40 UTC to 2016-07-01 22:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:31:40 UTC to 2016-07-01 22:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 22:51:40 UTC to 2016-07-01 22:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:11:40 UTC to 2016-07-01 23:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:31:40 UTC to 2016-07-01 23:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-01 23:51:40 UTC to 2016-07-01 23:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:11:40 UTC to 2016-07-02 00:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:31:40 UTC to 2016-07-02 00:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 00:51:40 UTC to 2016-07-02 00:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:11:40 UTC to 2016-07-02 01:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:31:40 UTC to 2016-07-02 01:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 01:51:40 UTC to 2016-07-02 01:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:11:40 UTC to 2016-07-02 02:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:31:40 UTC to 2016-07-02 02:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 02:51:40 UTC to 2016-07-02 02:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:11:40 UTC to 2016-07-02 03:12:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:31:40 UTC to 2016-07-02 03:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 03:51:40 UTC to 2016-07-02 03:52:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:11:39 UTC to 2016-07-02 04:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:31:40 UTC to 2016-07-02 04:32:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 04:51:39 UTC to 2016-07-02 04:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:11:39 UTC to 2016-07-02 05:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:31:39 UTC to 2016-07-02 05:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 05:51:39 UTC to 2016-07-02 05:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:11:39 UTC to 2016-07-02 06:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:31:39 UTC to 2016-07-02 06:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 06:51:39 UTC to 2016-07-02 06:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:11:39 UTC to 2016-07-02 07:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:31:39 UTC to 2016-07-02 07:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 07:51:39 UTC to 2016-07-02 07:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:11:39 UTC to 2016-07-02 08:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:31:39 UTC to 2016-07-02 08:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 08:51:39 UTC to 2016-07-02 08:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:11:39 UTC to 2016-07-02 09:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:31:39 UTC to 2016-07-02 09:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 09:51:39 UTC to 2016-07-02 09:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:11:39 UTC to 2016-07-02 10:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:31:39 UTC to 2016-07-02 10:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 10:51:39 UTC to 2016-07-02 10:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:11:39 UTC to 2016-07-02 11:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:31:39 UTC to 2016-07-02 11:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 11:51:39 UTC to 2016-07-02 11:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:11:39 UTC to 2016-07-02 12:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:31:39 UTC to 2016-07-02 12:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 12:51:39 UTC to 2016-07-02 12:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:11:39 UTC to 2016-07-02 13:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:31:39 UTC to 2016-07-02 13:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 13:51:39 UTC to 2016-07-02 13:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:11:39 UTC to 2016-07-02 14:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:31:39 UTC to 2016-07-02 14:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 14:51:39 UTC to 2016-07-02 14:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:11:39 UTC to 2016-07-02 15:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:31:39 UTC to 2016-07-02 15:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 15:51:39 UTC to 2016-07-02 15:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:11:39 UTC to 2016-07-02 16:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:31:39 UTC to 2016-07-02 16:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 16:51:39 UTC to 2016-07-02 16:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:11:39 UTC to 2016-07-02 17:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:31:39 UTC to 2016-07-02 17:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 17:51:39 UTC to 2016-07-02 17:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:11:39 UTC to 2016-07-02 18:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:31:39 UTC to 2016-07-02 18:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 18:51:39 UTC to 2016-07-02 18:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:11:39 UTC to 2016-07-02 19:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:31:39 UTC to 2016-07-02 19:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 19:51:39 UTC to 2016-07-02 19:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:11:39 UTC to 2016-07-02 20:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:31:39 UTC to 2016-07-02 20:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 20:51:39 UTC to 2016-07-02 20:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:11:39 UTC to 2016-07-02 21:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:31:39 UTC to 2016-07-02 21:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 21:51:39 UTC to 2016-07-02 21:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:11:39 UTC to 2016-07-02 22:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:31:39 UTC to 2016-07-02 22:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 22:51:39 UTC to 2016-07-02 22:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:11:39 UTC to 2016-07-02 23:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:31:39 UTC to 2016-07-02 23:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-02 23:51:39 UTC to 2016-07-02 23:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:11:39 UTC to 2016-07-03 00:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:31:39 UTC to 2016-07-03 00:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 00:51:39 UTC to 2016-07-03 00:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:11:39 UTC to 2016-07-03 01:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:31:39 UTC to 2016-07-03 01:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 01:51:39 UTC to 2016-07-03 01:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:11:39 UTC to 2016-07-03 02:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:31:39 UTC to 2016-07-03 02:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 02:51:39 UTC to 2016-07-03 02:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:11:39 UTC to 2016-07-03 03:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:31:39 UTC to 2016-07-03 03:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 03:51:39 UTC to 2016-07-03 03:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:11:39 UTC to 2016-07-03 04:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:31:39 UTC to 2016-07-03 04:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 04:51:39 UTC to 2016-07-03 04:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:11:39 UTC to 2016-07-03 05:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:31:39 UTC to 2016-07-03 05:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 05:51:39 UTC to 2016-07-03 05:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:11:39 UTC to 2016-07-03 06:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:31:39 UTC to 2016-07-03 06:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 06:51:39 UTC to 2016-07-03 06:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:11:39 UTC to 2016-07-03 07:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:31:39 UTC to 2016-07-03 07:31:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 07:51:39 UTC to 2016-07-03 07:51:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:11:39 UTC to 2016-07-03 08:11:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:31:38 UTC to 2016-07-03 08:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 08:51:38 UTC to 2016-07-03 08:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:11:38 UTC to 2016-07-03 09:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:31:38 UTC to 2016-07-03 09:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 09:51:38 UTC to 2016-07-03 09:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:11:38 UTC to 2016-07-03 10:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:31:38 UTC to 2016-07-03 10:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 10:51:38 UTC to 2016-07-03 10:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:11:38 UTC to 2016-07-03 11:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:31:38 UTC to 2016-07-03 11:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 11:51:38 UTC to 2016-07-03 11:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:11:38 UTC to 2016-07-03 12:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:31:38 UTC to 2016-07-03 12:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 12:51:38 UTC to 2016-07-03 12:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:11:38 UTC to 2016-07-03 13:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:31:38 UTC to 2016-07-03 13:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 13:51:38 UTC to 2016-07-03 13:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:11:38 UTC to 2016-07-03 14:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:31:38 UTC to 2016-07-03 14:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 14:51:38 UTC to 2016-07-03 14:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:11:38 UTC to 2016-07-03 15:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:31:38 UTC to 2016-07-03 15:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 15:51:38 UTC to 2016-07-03 15:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:11:38 UTC to 2016-07-03 16:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:31:38 UTC to 2016-07-03 16:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 16:51:38 UTC to 2016-07-03 16:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:11:38 UTC to 2016-07-03 17:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:31:38 UTC to 2016-07-03 17:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 17:51:38 UTC to 2016-07-03 17:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:11:38 UTC to 2016-07-03 18:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:31:38 UTC to 2016-07-03 18:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 18:51:38 UTC to 2016-07-03 18:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:11:38 UTC to 2016-07-03 19:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:31:38 UTC to 2016-07-03 19:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 19:51:38 UTC to 2016-07-03 19:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:11:38 UTC to 2016-07-03 20:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:31:38 UTC to 2016-07-03 20:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 20:51:38 UTC to 2016-07-03 20:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:11:38 UTC to 2016-07-03 21:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:31:38 UTC to 2016-07-03 21:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 21:51:38 UTC to 2016-07-03 21:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:11:38 UTC to 2016-07-03 22:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:31:38 UTC to 2016-07-03 22:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 22:51:38 UTC to 2016-07-03 22:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:11:38 UTC to 2016-07-03 23:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:31:38 UTC to 2016-07-03 23:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-03 23:51:38 UTC to 2016-07-03 23:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:11:38 UTC to 2016-07-04 00:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:31:38 UTC to 2016-07-04 00:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 00:51:38 UTC to 2016-07-04 00:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:11:38 UTC to 2016-07-04 01:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:31:38 UTC to 2016-07-04 01:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 01:51:38 UTC to 2016-07-04 01:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:11:38 UTC to 2016-07-04 02:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:31:38 UTC to 2016-07-04 02:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 02:51:38 UTC to 2016-07-04 02:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:11:38 UTC to 2016-07-04 03:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:31:38 UTC to 2016-07-04 03:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 03:51:38 UTC to 2016-07-04 03:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:11:38 UTC to 2016-07-04 04:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:31:38 UTC to 2016-07-04 04:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 04:51:38 UTC to 2016-07-04 04:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:11:38 UTC to 2016-07-04 05:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:31:38 UTC to 2016-07-04 05:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 05:51:38 UTC to 2016-07-04 05:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:11:38 UTC to 2016-07-04 06:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:31:38 UTC to 2016-07-04 06:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 06:51:38 UTC to 2016-07-04 06:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:11:38 UTC to 2016-07-04 07:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:31:38 UTC to 2016-07-04 07:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 07:51:38 UTC to 2016-07-04 07:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:11:38 UTC to 2016-07-04 08:11:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:31:38 UTC to 2016-07-04 08:31:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-04 08:51:38 UTC to 2016-07-04 08:51:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:18:19 UTC to 2016-07-05 02:18:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:28:18 UTC to 2016-07-05 02:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 02:48:18 UTC to 2016-07-05 02:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:08:18 UTC to 2016-07-05 03:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:28:18 UTC to 2016-07-05 03:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 03:48:18 UTC to 2016-07-05 03:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:08:18 UTC to 2016-07-05 04:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:28:18 UTC to 2016-07-05 04:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 04:48:18 UTC to 2016-07-05 04:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:08:18 UTC to 2016-07-05 05:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:28:18 UTC to 2016-07-05 05:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 05:48:18 UTC to 2016-07-05 05:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:08:18 UTC to 2016-07-05 06:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:28:18 UTC to 2016-07-05 06:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 06:48:18 UTC to 2016-07-05 06:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:08:18 UTC to 2016-07-05 07:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:28:18 UTC to 2016-07-05 07:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 07:48:18 UTC to 2016-07-05 07:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:08:18 UTC to 2016-07-05 08:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:28:18 UTC to 2016-07-05 08:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 08:48:18 UTC to 2016-07-05 08:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:08:18 UTC to 2016-07-05 09:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:28:18 UTC to 2016-07-05 09:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 09:48:18 UTC to 2016-07-05 09:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:08:18 UTC to 2016-07-05 10:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:28:18 UTC to 2016-07-05 10:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 10:48:18 UTC to 2016-07-05 10:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:08:18 UTC to 2016-07-05 11:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:28:18 UTC to 2016-07-05 11:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 11:48:18 UTC to 2016-07-05 11:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:08:18 UTC to 2016-07-05 12:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:28:18 UTC to 2016-07-05 12:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 12:48:18 UTC to 2016-07-05 12:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:08:18 UTC to 2016-07-05 13:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:28:18 UTC to 2016-07-05 13:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 13:48:18 UTC to 2016-07-05 13:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:08:18 UTC to 2016-07-05 14:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:28:18 UTC to 2016-07-05 14:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 14:48:18 UTC to 2016-07-05 14:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:08:18 UTC to 2016-07-05 15:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:28:18 UTC to 2016-07-05 15:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 15:48:18 UTC to 2016-07-05 15:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:08:18 UTC to 2016-07-05 16:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:28:18 UTC to 2016-07-05 16:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 16:48:18 UTC to 2016-07-05 16:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:08:18 UTC to 2016-07-05 17:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:28:18 UTC to 2016-07-05 17:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 17:48:18 UTC to 2016-07-05 17:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:08:18 UTC to 2016-07-05 18:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:28:18 UTC to 2016-07-05 18:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 18:48:18 UTC to 2016-07-05 18:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:08:18 UTC to 2016-07-05 19:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:28:18 UTC to 2016-07-05 19:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 19:48:18 UTC to 2016-07-05 19:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:08:18 UTC to 2016-07-05 20:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:28:18 UTC to 2016-07-05 20:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 20:48:18 UTC to 2016-07-05 20:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:08:18 UTC to 2016-07-05 21:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:28:18 UTC to 2016-07-05 21:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 21:48:18 UTC to 2016-07-05 21:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:08:18 UTC to 2016-07-05 22:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:28:18 UTC to 2016-07-05 22:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 22:48:18 UTC to 2016-07-05 22:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:08:18 UTC to 2016-07-05 23:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:28:18 UTC to 2016-07-05 23:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-05 23:48:17 UTC to 2016-07-05 23:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:08:18 UTC to 2016-07-06 00:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:28:18 UTC to 2016-07-06 00:28:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 00:48:18 UTC to 2016-07-06 00:48:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:08:18 UTC to 2016-07-06 01:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:28:17 UTC to 2016-07-06 01:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 01:48:17 UTC to 2016-07-06 01:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:08:18 UTC to 2016-07-06 02:08:38 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:28:17 UTC to 2016-07-06 02:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 02:48:17 UTC to 2016-07-06 02:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:08:17 UTC to 2016-07-06 03:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:28:17 UTC to 2016-07-06 03:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 03:48:17 UTC to 2016-07-06 03:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:08:17 UTC to 2016-07-06 04:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:28:17 UTC to 2016-07-06 04:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 04:48:17 UTC to 2016-07-06 04:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:08:17 UTC to 2016-07-06 05:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:28:17 UTC to 2016-07-06 05:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 05:48:17 UTC to 2016-07-06 05:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:08:17 UTC to 2016-07-06 06:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:28:17 UTC to 2016-07-06 06:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 06:48:17 UTC to 2016-07-06 06:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:08:17 UTC to 2016-07-06 07:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:28:17 UTC to 2016-07-06 07:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 07:48:17 UTC to 2016-07-06 07:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:08:17 UTC to 2016-07-06 08:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:28:17 UTC to 2016-07-06 08:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 08:48:17 UTC to 2016-07-06 08:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:08:17 UTC to 2016-07-06 09:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:28:17 UTC to 2016-07-06 09:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 09:48:17 UTC to 2016-07-06 09:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:08:17 UTC to 2016-07-06 10:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:28:17 UTC to 2016-07-06 10:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 10:48:17 UTC to 2016-07-06 10:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:08:17 UTC to 2016-07-06 11:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:28:17 UTC to 2016-07-06 11:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 11:48:17 UTC to 2016-07-06 11:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:08:17 UTC to 2016-07-06 12:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:28:17 UTC to 2016-07-06 12:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 12:48:17 UTC to 2016-07-06 12:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:08:17 UTC to 2016-07-06 13:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:28:17 UTC to 2016-07-06 13:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 13:48:17 UTC to 2016-07-06 13:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:08:17 UTC to 2016-07-06 14:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:28:17 UTC to 2016-07-06 14:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 14:48:17 UTC to 2016-07-06 14:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 15:28:17 UTC to 2016-07-06 15:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 15:48:17 UTC to 2016-07-06 15:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:08:17 UTC to 2016-07-06 16:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:28:17 UTC to 2016-07-06 16:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 16:48:17 UTC to 2016-07-06 16:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:08:17 UTC to 2016-07-06 17:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:28:17 UTC to 2016-07-06 17:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 17:48:17 UTC to 2016-07-06 17:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:08:17 UTC to 2016-07-06 18:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:28:17 UTC to 2016-07-06 18:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 18:48:17 UTC to 2016-07-06 18:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:08:17 UTC to 2016-07-06 19:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:28:17 UTC to 2016-07-06 19:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 19:48:17 UTC to 2016-07-06 19:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:08:17 UTC to 2016-07-06 20:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:28:17 UTC to 2016-07-06 20:28:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 20:48:17 UTC to 2016-07-06 20:48:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-06 21:08:17 UTC to 2016-07-06 21:08:37 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:02:35 UTC to 2016-07-09 00:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:12:35 UTC to 2016-07-09 00:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:32:35 UTC to 2016-07-09 00:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 00:52:35 UTC to 2016-07-09 00:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:12:35 UTC to 2016-07-09 01:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:32:35 UTC to 2016-07-09 01:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 01:52:35 UTC to 2016-07-09 01:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 02:32:35 UTC to 2016-07-09 02:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 02:52:35 UTC to 2016-07-09 02:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:12:35 UTC to 2016-07-09 03:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:32:35 UTC to 2016-07-09 03:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 03:52:35 UTC to 2016-07-09 03:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:12:35 UTC to 2016-07-09 04:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:32:35 UTC to 2016-07-09 04:32:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 04:52:35 UTC to 2016-07-09 04:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:12:35 UTC to 2016-07-09 05:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:32:34 UTC to 2016-07-09 05:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 05:52:35 UTC to 2016-07-09 05:52:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:12:35 UTC to 2016-07-09 06:12:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:32:34 UTC to 2016-07-09 06:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 06:52:34 UTC to 2016-07-09 06:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:12:34 UTC to 2016-07-09 07:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:32:34 UTC to 2016-07-09 07:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 07:52:34 UTC to 2016-07-09 07:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:12:34 UTC to 2016-07-09 08:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:32:34 UTC to 2016-07-09 08:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 08:52:34 UTC to 2016-07-09 08:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:12:34 UTC to 2016-07-09 09:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:32:34 UTC to 2016-07-09 09:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 09:52:34 UTC to 2016-07-09 09:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:12:34 UTC to 2016-07-09 10:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:32:34 UTC to 2016-07-09 10:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 10:52:34 UTC to 2016-07-09 10:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:12:34 UTC to 2016-07-09 11:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:32:34 UTC to 2016-07-09 11:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 11:52:34 UTC to 2016-07-09 11:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:12:34 UTC to 2016-07-09 12:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:32:34 UTC to 2016-07-09 12:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 12:52:34 UTC to 2016-07-09 12:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:12:34 UTC to 2016-07-09 13:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:32:34 UTC to 2016-07-09 13:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 13:52:34 UTC to 2016-07-09 13:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:12:34 UTC to 2016-07-09 14:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:32:34 UTC to 2016-07-09 14:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 14:52:34 UTC to 2016-07-09 14:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:12:34 UTC to 2016-07-09 15:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:32:34 UTC to 2016-07-09 15:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 15:52:34 UTC to 2016-07-09 15:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:12:34 UTC to 2016-07-09 16:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:32:34 UTC to 2016-07-09 16:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 16:52:34 UTC to 2016-07-09 16:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:12:34 UTC to 2016-07-09 17:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:32:34 UTC to 2016-07-09 17:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 17:52:34 UTC to 2016-07-09 17:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:12:34 UTC to 2016-07-09 18:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:32:34 UTC to 2016-07-09 18:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 18:52:34 UTC to 2016-07-09 18:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:12:34 UTC to 2016-07-09 19:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:32:34 UTC to 2016-07-09 19:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 19:52:34 UTC to 2016-07-09 19:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:12:34 UTC to 2016-07-09 20:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:32:34 UTC to 2016-07-09 20:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 20:52:34 UTC to 2016-07-09 20:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:12:34 UTC to 2016-07-09 21:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:32:34 UTC to 2016-07-09 21:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 21:52:34 UTC to 2016-07-09 21:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:12:34 UTC to 2016-07-09 22:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:32:34 UTC to 2016-07-09 22:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 22:52:34 UTC to 2016-07-09 22:52:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 23:12:34 UTC to 2016-07-09 23:12:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-09 23:32:34 UTC to 2016-07-09 23:32:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 01:53:30 UTC to 2016-07-11 01:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:13:30 UTC to 2016-07-11 02:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:33:30 UTC to 2016-07-11 02:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 02:53:30 UTC to 2016-07-11 02:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:13:30 UTC to 2016-07-11 03:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:33:30 UTC to 2016-07-11 03:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 03:53:30 UTC to 2016-07-11 03:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:13:30 UTC to 2016-07-11 04:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:33:30 UTC to 2016-07-11 04:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 04:53:30 UTC to 2016-07-11 04:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:13:30 UTC to 2016-07-11 05:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:33:30 UTC to 2016-07-11 05:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 05:53:30 UTC to 2016-07-11 05:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:13:30 UTC to 2016-07-11 06:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:33:30 UTC to 2016-07-11 06:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 06:53:30 UTC to 2016-07-11 06:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:13:30 UTC to 2016-07-11 07:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:33:30 UTC to 2016-07-11 07:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 07:53:30 UTC to 2016-07-11 07:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:13:29 UTC to 2016-07-11 08:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:33:30 UTC to 2016-07-11 08:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 08:53:30 UTC to 2016-07-11 08:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:13:30 UTC to 2016-07-11 09:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:33:29 UTC to 2016-07-11 09:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 09:53:29 UTC to 2016-07-11 09:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:13:30 UTC to 2016-07-11 10:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:33:29 UTC to 2016-07-11 10:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 10:53:30 UTC to 2016-07-11 10:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:13:29 UTC to 2016-07-11 11:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:33:29 UTC to 2016-07-11 11:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 11:53:29 UTC to 2016-07-11 11:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:13:29 UTC to 2016-07-11 12:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:33:29 UTC to 2016-07-11 12:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 12:53:29 UTC to 2016-07-11 12:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:13:29 UTC to 2016-07-11 13:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:33:29 UTC to 2016-07-11 13:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 13:53:29 UTC to 2016-07-11 13:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:13:29 UTC to 2016-07-11 14:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:33:29 UTC to 2016-07-11 14:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 14:53:29 UTC to 2016-07-11 14:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:13:29 UTC to 2016-07-11 15:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:33:29 UTC to 2016-07-11 15:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 15:53:30 UTC to 2016-07-11 15:53:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:13:30 UTC to 2016-07-11 16:13:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:33:29 UTC to 2016-07-11 16:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 16:53:29 UTC to 2016-07-11 16:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:13:29 UTC to 2016-07-11 17:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:33:29 UTC to 2016-07-11 17:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 17:53:29 UTC to 2016-07-11 17:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:13:29 UTC to 2016-07-11 18:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:33:29 UTC to 2016-07-11 18:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 18:53:29 UTC to 2016-07-11 18:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:13:29 UTC to 2016-07-11 19:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:33:30 UTC to 2016-07-11 19:33:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 19:53:29 UTC to 2016-07-11 19:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:13:29 UTC to 2016-07-11 20:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:33:29 UTC to 2016-07-11 20:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 20:53:29 UTC to 2016-07-11 20:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:13:29 UTC to 2016-07-11 21:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:33:29 UTC to 2016-07-11 21:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 21:53:29 UTC to 2016-07-11 21:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:13:29 UTC to 2016-07-11 22:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:33:29 UTC to 2016-07-11 22:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 22:53:29 UTC to 2016-07-11 22:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:13:29 UTC to 2016-07-11 23:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:33:29 UTC to 2016-07-11 23:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-11 23:53:29 UTC to 2016-07-11 23:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:13:29 UTC to 2016-07-12 00:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:33:29 UTC to 2016-07-12 00:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 00:53:29 UTC to 2016-07-12 00:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:13:29 UTC to 2016-07-12 01:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:33:29 UTC to 2016-07-12 01:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 01:53:29 UTC to 2016-07-12 01:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:13:29 UTC to 2016-07-12 02:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:33:29 UTC to 2016-07-12 02:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 02:53:29 UTC to 2016-07-12 02:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:13:29 UTC to 2016-07-12 03:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:33:29 UTC to 2016-07-12 03:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 03:53:29 UTC to 2016-07-12 03:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:13:29 UTC to 2016-07-12 04:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:33:29 UTC to 2016-07-12 04:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 04:53:29 UTC to 2016-07-12 04:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:13:29 UTC to 2016-07-12 05:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:33:29 UTC to 2016-07-12 05:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 05:53:29 UTC to 2016-07-12 05:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:13:29 UTC to 2016-07-12 06:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:33:29 UTC to 2016-07-12 06:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 06:53:29 UTC to 2016-07-12 06:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:13:29 UTC to 2016-07-12 07:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:33:29 UTC to 2016-07-12 07:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 07:53:29 UTC to 2016-07-12 07:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:13:29 UTC to 2016-07-12 08:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:33:29 UTC to 2016-07-12 08:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 08:53:29 UTC to 2016-07-12 08:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:13:29 UTC to 2016-07-12 09:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:33:29 UTC to 2016-07-12 09:33:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 09:53:29 UTC to 2016-07-12 09:53:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-12 10:13:29 UTC to 2016-07-12 10:13:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:09:27 UTC to 2016-07-13 18:09:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:19:28 UTC to 2016-07-13 18:19:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:39:28 UTC to 2016-07-13 18:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 18:59:28 UTC to 2016-07-13 18:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:19:27 UTC to 2016-07-13 19:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:39:28 UTC to 2016-07-13 19:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 19:59:28 UTC to 2016-07-13 19:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:19:27 UTC to 2016-07-13 20:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:39:28 UTC to 2016-07-13 20:39:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 20:59:27 UTC to 2016-07-13 20:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:19:27 UTC to 2016-07-13 21:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:39:27 UTC to 2016-07-13 21:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 21:59:27 UTC to 2016-07-13 21:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:19:27 UTC to 2016-07-13 22:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:39:27 UTC to 2016-07-13 22:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 22:59:27 UTC to 2016-07-13 22:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:19:27 UTC to 2016-07-13 23:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:39:27 UTC to 2016-07-13 23:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-13 23:59:28 UTC to 2016-07-13 23:59:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 00:19:27 UTC to 2016-07-14 00:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 00:59:27 UTC to 2016-07-14 00:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:19:27 UTC to 2016-07-14 01:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:39:27 UTC to 2016-07-14 01:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 01:59:27 UTC to 2016-07-14 01:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:19:27 UTC to 2016-07-14 02:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:39:27 UTC to 2016-07-14 02:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 02:59:27 UTC to 2016-07-14 02:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:19:27 UTC to 2016-07-14 03:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:39:27 UTC to 2016-07-14 03:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 03:59:27 UTC to 2016-07-14 03:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:19:27 UTC to 2016-07-14 04:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:39:27 UTC to 2016-07-14 04:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 04:59:27 UTC to 2016-07-14 04:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:19:27 UTC to 2016-07-14 05:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:39:27 UTC to 2016-07-14 05:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 05:59:27 UTC to 2016-07-14 05:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:19:27 UTC to 2016-07-14 06:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:39:27 UTC to 2016-07-14 06:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 06:59:27 UTC to 2016-07-14 06:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:19:27 UTC to 2016-07-14 07:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:39:27 UTC to 2016-07-14 07:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 07:59:27 UTC to 2016-07-14 07:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:19:27 UTC to 2016-07-14 08:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:39:27 UTC to 2016-07-14 08:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 08:59:27 UTC to 2016-07-14 08:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:19:27 UTC to 2016-07-14 09:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:39:27 UTC to 2016-07-14 09:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 09:59:27 UTC to 2016-07-14 09:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:19:27 UTC to 2016-07-14 10:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:39:27 UTC to 2016-07-14 10:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 10:59:27 UTC to 2016-07-14 10:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:19:27 UTC to 2016-07-14 11:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:39:27 UTC to 2016-07-14 11:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 11:59:27 UTC to 2016-07-14 11:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:19:27 UTC to 2016-07-14 12:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:39:27 UTC to 2016-07-14 12:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 12:59:27 UTC to 2016-07-14 12:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:19:27 UTC to 2016-07-14 13:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:39:27 UTC to 2016-07-14 13:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 13:59:27 UTC to 2016-07-14 13:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:19:27 UTC to 2016-07-14 14:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:39:27 UTC to 2016-07-14 14:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 14:59:27 UTC to 2016-07-14 14:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:19:27 UTC to 2016-07-14 15:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:39:27 UTC to 2016-07-14 15:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 15:59:27 UTC to 2016-07-14 15:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:19:27 UTC to 2016-07-14 16:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:39:27 UTC to 2016-07-14 16:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 16:59:27 UTC to 2016-07-14 16:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:19:27 UTC to 2016-07-14 17:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:39:27 UTC to 2016-07-14 17:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 17:59:27 UTC to 2016-07-14 17:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:19:27 UTC to 2016-07-14 18:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:39:27 UTC to 2016-07-14 18:39:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 18:59:27 UTC to 2016-07-14 18:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:19:27 UTC to 2016-07-14 19:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:39:26 UTC to 2016-07-14 19:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 19:59:27 UTC to 2016-07-14 19:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:19:27 UTC to 2016-07-14 20:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:39:26 UTC to 2016-07-14 20:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 20:59:27 UTC to 2016-07-14 20:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:19:26 UTC to 2016-07-14 21:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:39:26 UTC to 2016-07-14 21:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 21:59:26 UTC to 2016-07-14 21:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:19:26 UTC to 2016-07-14 22:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:39:26 UTC to 2016-07-14 22:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 22:59:27 UTC to 2016-07-14 22:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:19:26 UTC to 2016-07-14 23:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:39:26 UTC to 2016-07-14 23:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-14 23:59:26 UTC to 2016-07-14 23:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:19:26 UTC to 2016-07-15 00:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:39:26 UTC to 2016-07-15 00:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 00:59:27 UTC to 2016-07-15 00:59:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 01:19:27 UTC to 2016-07-15 01:19:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 01:59:26 UTC to 2016-07-15 01:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:19:26 UTC to 2016-07-15 02:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:39:26 UTC to 2016-07-15 02:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 02:59:26 UTC to 2016-07-15 02:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:19:26 UTC to 2016-07-15 03:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:39:26 UTC to 2016-07-15 03:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 03:59:26 UTC to 2016-07-15 03:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:19:26 UTC to 2016-07-15 04:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:39:26 UTC to 2016-07-15 04:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 04:59:26 UTC to 2016-07-15 04:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 05:19:26 UTC to 2016-07-15 05:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 05:39:26 UTC to 2016-07-15 05:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:19:26 UTC to 2016-07-15 06:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:39:26 UTC to 2016-07-15 06:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 06:59:26 UTC to 2016-07-15 06:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:19:26 UTC to 2016-07-15 07:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:39:26 UTC to 2016-07-15 07:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 07:59:26 UTC to 2016-07-15 07:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:19:26 UTC to 2016-07-15 08:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:39:26 UTC to 2016-07-15 08:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 08:59:26 UTC to 2016-07-15 08:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:19:26 UTC to 2016-07-15 09:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:39:26 UTC to 2016-07-15 09:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 09:59:26 UTC to 2016-07-15 09:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:19:26 UTC to 2016-07-15 10:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:39:26 UTC to 2016-07-15 10:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 10:59:26 UTC to 2016-07-15 10:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:19:26 UTC to 2016-07-15 11:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:39:26 UTC to 2016-07-15 11:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 11:59:26 UTC to 2016-07-15 11:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 19:39:26 UTC to 2016-07-15 19:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 19:59:26 UTC to 2016-07-15 19:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:19:26 UTC to 2016-07-15 20:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:39:26 UTC to 2016-07-15 20:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 20:59:26 UTC to 2016-07-15 20:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:19:26 UTC to 2016-07-15 21:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:39:26 UTC to 2016-07-15 21:39:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 21:59:26 UTC to 2016-07-15 21:59:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:19:26 UTC to 2016-07-15 22:19:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:39:25 UTC to 2016-07-15 22:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 22:59:25 UTC to 2016-07-15 22:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:19:25 UTC to 2016-07-15 23:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:39:25 UTC to 2016-07-15 23:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-15 23:59:25 UTC to 2016-07-15 23:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:19:25 UTC to 2016-07-16 00:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:39:25 UTC to 2016-07-16 00:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 00:59:25 UTC to 2016-07-16 00:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:19:25 UTC to 2016-07-16 01:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:39:25 UTC to 2016-07-16 01:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 01:59:25 UTC to 2016-07-16 01:59:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 02:19:25 UTC to 2016-07-16 02:19:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-16 02:39:25 UTC to 2016-07-16 02:39:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:26:55 UTC to 2016-07-17 16:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:36:55 UTC to 2016-07-17 16:37:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 16:46:55 UTC to 2016-07-17 16:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:06:55 UTC to 2016-07-17 17:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:26:55 UTC to 2016-07-17 17:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 17:46:55 UTC to 2016-07-17 17:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:06:55 UTC to 2016-07-17 18:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:26:55 UTC to 2016-07-17 18:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 18:46:55 UTC to 2016-07-17 18:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:06:55 UTC to 2016-07-17 19:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:26:55 UTC to 2016-07-17 19:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 19:46:55 UTC to 2016-07-17 19:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:06:55 UTC to 2016-07-17 20:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:26:55 UTC to 2016-07-17 20:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 20:46:55 UTC to 2016-07-17 20:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:06:55 UTC to 2016-07-17 21:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:26:55 UTC to 2016-07-17 21:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 21:46:55 UTC to 2016-07-17 21:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:06:55 UTC to 2016-07-17 22:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:26:55 UTC to 2016-07-17 22:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 22:46:55 UTC to 2016-07-17 22:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:06:55 UTC to 2016-07-17 23:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:26:55 UTC to 2016-07-17 23:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-17 23:46:55 UTC to 2016-07-17 23:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:06:55 UTC to 2016-07-18 00:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:26:55 UTC to 2016-07-18 00:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 00:46:54 UTC to 2016-07-18 00:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:06:55 UTC to 2016-07-18 01:07:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:26:55 UTC to 2016-07-18 01:27:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 01:46:54 UTC to 2016-07-18 01:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:06:54 UTC to 2016-07-18 02:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:26:54 UTC to 2016-07-18 02:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 02:46:55 UTC to 2016-07-18 02:47:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:06:54 UTC to 2016-07-18 03:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:26:54 UTC to 2016-07-18 03:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 03:46:54 UTC to 2016-07-18 03:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:06:54 UTC to 2016-07-18 04:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:26:54 UTC to 2016-07-18 04:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 04:46:54 UTC to 2016-07-18 04:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:06:54 UTC to 2016-07-18 05:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:26:54 UTC to 2016-07-18 05:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 05:46:54 UTC to 2016-07-18 05:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:06:54 UTC to 2016-07-18 06:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:26:54 UTC to 2016-07-18 06:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 06:46:54 UTC to 2016-07-18 06:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:06:54 UTC to 2016-07-18 07:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:26:54 UTC to 2016-07-18 07:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 07:46:54 UTC to 2016-07-18 07:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:06:54 UTC to 2016-07-18 08:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:26:54 UTC to 2016-07-18 08:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 08:46:54 UTC to 2016-07-18 08:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:06:54 UTC to 2016-07-18 09:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:26:54 UTC to 2016-07-18 09:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 09:46:54 UTC to 2016-07-18 09:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:06:54 UTC to 2016-07-18 10:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:26:54 UTC to 2016-07-18 10:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 10:46:54 UTC to 2016-07-18 10:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:06:54 UTC to 2016-07-18 11:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:26:54 UTC to 2016-07-18 11:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 11:46:54 UTC to 2016-07-18 11:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:06:54 UTC to 2016-07-18 12:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:26:54 UTC to 2016-07-18 12:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 12:46:54 UTC to 2016-07-18 12:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:06:54 UTC to 2016-07-18 13:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:26:54 UTC to 2016-07-18 13:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 13:46:54 UTC to 2016-07-18 13:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:06:54 UTC to 2016-07-18 14:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:26:54 UTC to 2016-07-18 14:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 14:46:54 UTC to 2016-07-18 14:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:06:54 UTC to 2016-07-18 15:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:26:54 UTC to 2016-07-18 15:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 15:46:54 UTC to 2016-07-18 15:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:06:54 UTC to 2016-07-18 16:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:26:54 UTC to 2016-07-18 16:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 16:46:54 UTC to 2016-07-18 16:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:06:54 UTC to 2016-07-18 17:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:26:54 UTC to 2016-07-18 17:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 17:46:54 UTC to 2016-07-18 17:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:06:54 UTC to 2016-07-18 18:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:26:54 UTC to 2016-07-18 18:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 18:46:54 UTC to 2016-07-18 18:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:06:54 UTC to 2016-07-18 19:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:26:54 UTC to 2016-07-18 19:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 19:46:54 UTC to 2016-07-18 19:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:06:54 UTC to 2016-07-18 20:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:26:54 UTC to 2016-07-18 20:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 20:46:54 UTC to 2016-07-18 20:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:06:54 UTC to 2016-07-18 21:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:26:54 UTC to 2016-07-18 21:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 21:46:54 UTC to 2016-07-18 21:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:06:54 UTC to 2016-07-18 22:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:26:54 UTC to 2016-07-18 22:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 22:46:54 UTC to 2016-07-18 22:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:06:54 UTC to 2016-07-18 23:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:26:54 UTC to 2016-07-18 23:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-18 23:46:54 UTC to 2016-07-18 23:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:06:54 UTC to 2016-07-19 00:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:26:54 UTC to 2016-07-19 00:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 00:46:54 UTC to 2016-07-19 00:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:06:54 UTC to 2016-07-19 01:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:26:54 UTC to 2016-07-19 01:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 01:46:54 UTC to 2016-07-19 01:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:06:54 UTC to 2016-07-19 02:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:26:54 UTC to 2016-07-19 02:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 02:46:54 UTC to 2016-07-19 02:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:06:54 UTC to 2016-07-19 03:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:26:54 UTC to 2016-07-19 03:27:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 03:46:54 UTC to 2016-07-19 03:47:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:06:54 UTC to 2016-07-19 04:07:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:26:53 UTC to 2016-07-19 04:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 04:46:53 UTC to 2016-07-19 04:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:06:53 UTC to 2016-07-19 05:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:26:53 UTC to 2016-07-19 05:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 05:46:53 UTC to 2016-07-19 05:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:06:53 UTC to 2016-07-19 06:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:26:53 UTC to 2016-07-19 06:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 06:46:53 UTC to 2016-07-19 06:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:06:53 UTC to 2016-07-19 07:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:26:53 UTC to 2016-07-19 07:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 07:46:53 UTC to 2016-07-19 07:47:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 08:06:53 UTC to 2016-07-19 08:07:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 08:26:53 UTC to 2016-07-19 08:27:13 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 23:26:30 UTC to 2016-07-19 23:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-19 23:46:30 UTC to 2016-07-19 23:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:06:30 UTC to 2016-07-20 00:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:26:30 UTC to 2016-07-20 00:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 00:46:30 UTC to 2016-07-20 00:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:06:30 UTC to 2016-07-20 01:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:26:30 UTC to 2016-07-20 01:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 01:46:30 UTC to 2016-07-20 01:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:06:30 UTC to 2016-07-20 02:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:26:30 UTC to 2016-07-20 02:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 02:46:30 UTC to 2016-07-20 02:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:06:30 UTC to 2016-07-20 03:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:26:30 UTC to 2016-07-20 03:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 03:46:30 UTC to 2016-07-20 03:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:06:30 UTC to 2016-07-20 04:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:26:30 UTC to 2016-07-20 04:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 04:46:30 UTC to 2016-07-20 04:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:06:30 UTC to 2016-07-20 05:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:26:30 UTC to 2016-07-20 05:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 05:46:30 UTC to 2016-07-20 05:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:06:30 UTC to 2016-07-20 06:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:26:30 UTC to 2016-07-20 06:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 06:46:30 UTC to 2016-07-20 06:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:06:30 UTC to 2016-07-20 07:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:26:30 UTC to 2016-07-20 07:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 07:46:30 UTC to 2016-07-20 07:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:06:30 UTC to 2016-07-20 08:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:26:30 UTC to 2016-07-20 08:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 08:46:30 UTC to 2016-07-20 08:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:06:30 UTC to 2016-07-20 09:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:26:30 UTC to 2016-07-20 09:26:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 09:46:30 UTC to 2016-07-20 09:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:06:30 UTC to 2016-07-20 10:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:26:29 UTC to 2016-07-20 10:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 10:46:30 UTC to 2016-07-20 10:46:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:06:30 UTC to 2016-07-20 11:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:26:29 UTC to 2016-07-20 11:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 11:46:29 UTC to 2016-07-20 11:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:06:30 UTC to 2016-07-20 12:06:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:26:29 UTC to 2016-07-20 12:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 12:46:29 UTC to 2016-07-20 12:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:06:29 UTC to 2016-07-20 13:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:26:29 UTC to 2016-07-20 13:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 13:46:29 UTC to 2016-07-20 13:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:06:29 UTC to 2016-07-20 14:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:26:29 UTC to 2016-07-20 14:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 14:46:29 UTC to 2016-07-20 14:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:06:29 UTC to 2016-07-20 15:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:26:29 UTC to 2016-07-20 15:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 15:46:29 UTC to 2016-07-20 15:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:06:29 UTC to 2016-07-20 16:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:26:29 UTC to 2016-07-20 16:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 16:46:29 UTC to 2016-07-20 16:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:06:29 UTC to 2016-07-20 17:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:26:29 UTC to 2016-07-20 17:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 17:46:29 UTC to 2016-07-20 17:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:06:29 UTC to 2016-07-20 18:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:26:29 UTC to 2016-07-20 18:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 18:46:29 UTC to 2016-07-20 18:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:06:29 UTC to 2016-07-20 19:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:26:29 UTC to 2016-07-20 19:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 19:46:29 UTC to 2016-07-20 19:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:06:29 UTC to 2016-07-20 20:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:26:29 UTC to 2016-07-20 20:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 20:46:29 UTC to 2016-07-20 20:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:06:29 UTC to 2016-07-20 21:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:26:29 UTC to 2016-07-20 21:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 21:46:29 UTC to 2016-07-20 21:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:06:29 UTC to 2016-07-20 22:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:26:29 UTC to 2016-07-20 22:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 22:46:29 UTC to 2016-07-20 22:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:06:29 UTC to 2016-07-20 23:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:26:29 UTC to 2016-07-20 23:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-20 23:46:29 UTC to 2016-07-20 23:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:06:29 UTC to 2016-07-21 00:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:26:29 UTC to 2016-07-21 00:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 00:46:29 UTC to 2016-07-21 00:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:06:29 UTC to 2016-07-21 01:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:26:29 UTC to 2016-07-21 01:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 01:46:29 UTC to 2016-07-21 01:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:06:29 UTC to 2016-07-21 02:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:26:29 UTC to 2016-07-21 02:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 02:46:29 UTC to 2016-07-21 02:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:06:29 UTC to 2016-07-21 03:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:26:29 UTC to 2016-07-21 03:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 03:46:29 UTC to 2016-07-21 03:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:06:29 UTC to 2016-07-21 04:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:26:29 UTC to 2016-07-21 04:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 04:46:29 UTC to 2016-07-21 04:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:06:29 UTC to 2016-07-21 05:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:26:29 UTC to 2016-07-21 05:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 05:46:29 UTC to 2016-07-21 05:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:06:29 UTC to 2016-07-21 06:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:26:29 UTC to 2016-07-21 06:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 06:46:29 UTC to 2016-07-21 06:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:06:29 UTC to 2016-07-21 07:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:26:29 UTC to 2016-07-21 07:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 07:46:29 UTC to 2016-07-21 07:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:06:29 UTC to 2016-07-21 08:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:26:29 UTC to 2016-07-21 08:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 08:46:29 UTC to 2016-07-21 08:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:06:29 UTC to 2016-07-21 09:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:26:29 UTC to 2016-07-21 09:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 09:46:29 UTC to 2016-07-21 09:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:06:29 UTC to 2016-07-21 10:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:26:29 UTC to 2016-07-21 10:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 10:46:29 UTC to 2016-07-21 10:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:06:29 UTC to 2016-07-21 11:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:26:29 UTC to 2016-07-21 11:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 11:46:29 UTC to 2016-07-21 11:46:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:06:29 UTC to 2016-07-21 12:06:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:26:29 UTC to 2016-07-21 12:26:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-21 12:46:28 UTC to 2016-07-21 12:46:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:05:48 UTC to 2016-07-22 17:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:25:48 UTC to 2016-07-22 17:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 17:45:48 UTC to 2016-07-22 17:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:05:48 UTC to 2016-07-22 18:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:25:48 UTC to 2016-07-22 18:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 18:45:48 UTC to 2016-07-22 18:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:05:48 UTC to 2016-07-22 19:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:25:48 UTC to 2016-07-22 19:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 19:45:48 UTC to 2016-07-22 19:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:05:48 UTC to 2016-07-22 20:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:25:48 UTC to 2016-07-22 20:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 20:45:48 UTC to 2016-07-22 20:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:05:48 UTC to 2016-07-22 21:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:25:48 UTC to 2016-07-22 21:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 21:45:48 UTC to 2016-07-22 21:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:05:48 UTC to 2016-07-22 22:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:25:48 UTC to 2016-07-22 22:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 22:45:48 UTC to 2016-07-22 22:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:05:48 UTC to 2016-07-22 23:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:25:48 UTC to 2016-07-22 23:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-22 23:45:48 UTC to 2016-07-22 23:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:05:48 UTC to 2016-07-23 00:06:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:25:48 UTC to 2016-07-23 00:26:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 00:45:48 UTC to 2016-07-23 00:46:08 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:05:47 UTC to 2016-07-23 01:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:25:47 UTC to 2016-07-23 01:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 01:45:47 UTC to 2016-07-23 01:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:05:47 UTC to 2016-07-23 02:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:25:47 UTC to 2016-07-23 02:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 02:45:47 UTC to 2016-07-23 02:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:05:47 UTC to 2016-07-23 03:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:25:47 UTC to 2016-07-23 03:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 03:45:47 UTC to 2016-07-23 03:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:05:47 UTC to 2016-07-23 04:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:25:47 UTC to 2016-07-23 04:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 04:45:47 UTC to 2016-07-23 04:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:05:47 UTC to 2016-07-23 05:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:25:47 UTC to 2016-07-23 05:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 05:45:47 UTC to 2016-07-23 05:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:05:47 UTC to 2016-07-23 06:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:25:47 UTC to 2016-07-23 06:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 06:45:47 UTC to 2016-07-23 06:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:05:47 UTC to 2016-07-23 07:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:25:47 UTC to 2016-07-23 07:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 07:45:47 UTC to 2016-07-23 07:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:05:47 UTC to 2016-07-23 08:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:25:47 UTC to 2016-07-23 08:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 08:45:47 UTC to 2016-07-23 08:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:05:47 UTC to 2016-07-23 09:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:25:47 UTC to 2016-07-23 09:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 09:45:47 UTC to 2016-07-23 09:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:05:47 UTC to 2016-07-23 10:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:25:47 UTC to 2016-07-23 10:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 10:45:47 UTC to 2016-07-23 10:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:05:47 UTC to 2016-07-23 11:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:25:47 UTC to 2016-07-23 11:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 11:45:47 UTC to 2016-07-23 11:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:05:47 UTC to 2016-07-23 12:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:25:47 UTC to 2016-07-23 12:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 12:45:47 UTC to 2016-07-23 12:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:05:47 UTC to 2016-07-23 13:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:25:47 UTC to 2016-07-23 13:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 13:45:47 UTC to 2016-07-23 13:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:05:47 UTC to 2016-07-23 14:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:25:47 UTC to 2016-07-23 14:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 14:45:47 UTC to 2016-07-23 14:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:05:47 UTC to 2016-07-23 15:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:25:47 UTC to 2016-07-23 15:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 15:45:47 UTC to 2016-07-23 15:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:05:47 UTC to 2016-07-23 16:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:25:47 UTC to 2016-07-23 16:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 16:45:47 UTC to 2016-07-23 16:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:05:47 UTC to 2016-07-23 17:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:25:47 UTC to 2016-07-23 17:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 17:45:47 UTC to 2016-07-23 17:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:05:47 UTC to 2016-07-23 18:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:25:47 UTC to 2016-07-23 18:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 18:45:47 UTC to 2016-07-23 18:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:05:47 UTC to 2016-07-23 19:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:25:47 UTC to 2016-07-23 19:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 19:45:47 UTC to 2016-07-23 19:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:05:47 UTC to 2016-07-23 20:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:25:47 UTC to 2016-07-23 20:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 20:45:47 UTC to 2016-07-23 20:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:05:47 UTC to 2016-07-23 21:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:25:47 UTC to 2016-07-23 21:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 21:45:47 UTC to 2016-07-23 21:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:05:47 UTC to 2016-07-23 22:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:25:47 UTC to 2016-07-23 22:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 22:45:47 UTC to 2016-07-23 22:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:05:47 UTC to 2016-07-23 23:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:25:47 UTC to 2016-07-23 23:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-23 23:45:47 UTC to 2016-07-23 23:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:05:47 UTC to 2016-07-24 00:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:25:47 UTC to 2016-07-24 00:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 00:45:47 UTC to 2016-07-24 00:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:05:47 UTC to 2016-07-24 01:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:25:47 UTC to 2016-07-24 01:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 01:45:47 UTC to 2016-07-24 01:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:05:47 UTC to 2016-07-24 02:06:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:25:47 UTC to 2016-07-24 02:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 02:45:47 UTC to 2016-07-24 02:46:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:05:46 UTC to 2016-07-24 03:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:25:47 UTC to 2016-07-24 03:26:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 03:45:46 UTC to 2016-07-24 03:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:05:46 UTC to 2016-07-24 04:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:25:46 UTC to 2016-07-24 04:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 04:45:46 UTC to 2016-07-24 04:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:05:46 UTC to 2016-07-24 05:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:25:46 UTC to 2016-07-24 05:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 05:45:46 UTC to 2016-07-24 05:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:05:46 UTC to 2016-07-24 06:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:25:46 UTC to 2016-07-24 06:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 06:45:46 UTC to 2016-07-24 06:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:05:46 UTC to 2016-07-24 07:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:25:46 UTC to 2016-07-24 07:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 07:45:46 UTC to 2016-07-24 07:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:05:46 UTC to 2016-07-24 08:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:25:46 UTC to 2016-07-24 08:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 08:45:46 UTC to 2016-07-24 08:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:05:46 UTC to 2016-07-24 09:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:25:46 UTC to 2016-07-24 09:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 09:45:46 UTC to 2016-07-24 09:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:05:46 UTC to 2016-07-24 10:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:25:46 UTC to 2016-07-24 10:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 10:45:46 UTC to 2016-07-24 10:46:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 11:05:46 UTC to 2016-07-24 11:06:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-24 11:25:46 UTC to 2016-07-24 11:26:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 00:50:03 UTC to 2016-07-25 00:50:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:00:03 UTC to 2016-07-25 01:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:20:03 UTC to 2016-07-25 01:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 01:40:03 UTC to 2016-07-25 01:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:00:03 UTC to 2016-07-25 02:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:20:03 UTC to 2016-07-25 02:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 02:40:03 UTC to 2016-07-25 02:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:00:03 UTC to 2016-07-25 03:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:20:03 UTC to 2016-07-25 03:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 03:40:03 UTC to 2016-07-25 03:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:00:03 UTC to 2016-07-25 04:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:20:03 UTC to 2016-07-25 04:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 04:40:03 UTC to 2016-07-25 04:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:00:03 UTC to 2016-07-25 05:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:20:03 UTC to 2016-07-25 05:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 05:40:03 UTC to 2016-07-25 05:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:00:03 UTC to 2016-07-25 06:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:20:03 UTC to 2016-07-25 06:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 06:40:03 UTC to 2016-07-25 06:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:00:03 UTC to 2016-07-25 07:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:20:03 UTC to 2016-07-25 07:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 07:40:03 UTC to 2016-07-25 07:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:00:03 UTC to 2016-07-25 08:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:20:03 UTC to 2016-07-25 08:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 08:40:03 UTC to 2016-07-25 08:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:00:03 UTC to 2016-07-25 09:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:20:03 UTC to 2016-07-25 09:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 09:40:03 UTC to 2016-07-25 09:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:00:03 UTC to 2016-07-25 10:00:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:20:03 UTC to 2016-07-25 10:20:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 10:40:03 UTC to 2016-07-25 10:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:00:02 UTC to 2016-07-25 11:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:20:02 UTC to 2016-07-25 11:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 11:40:03 UTC to 2016-07-25 11:40:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:00:02 UTC to 2016-07-25 12:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:20:02 UTC to 2016-07-25 12:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 12:40:02 UTC to 2016-07-25 12:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:00:02 UTC to 2016-07-25 13:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:20:02 UTC to 2016-07-25 13:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 13:40:02 UTC to 2016-07-25 13:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:00:02 UTC to 2016-07-25 14:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:20:02 UTC to 2016-07-25 14:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 14:40:02 UTC to 2016-07-25 14:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:00:02 UTC to 2016-07-25 15:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:20:02 UTC to 2016-07-25 15:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 15:40:02 UTC to 2016-07-25 15:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:00:02 UTC to 2016-07-25 16:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:20:02 UTC to 2016-07-25 16:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 16:40:02 UTC to 2016-07-25 16:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:00:02 UTC to 2016-07-25 17:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:20:02 UTC to 2016-07-25 17:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 17:40:02 UTC to 2016-07-25 17:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:00:02 UTC to 2016-07-25 18:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:20:02 UTC to 2016-07-25 18:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 18:40:02 UTC to 2016-07-25 18:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:00:02 UTC to 2016-07-25 19:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:20:02 UTC to 2016-07-25 19:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 19:40:02 UTC to 2016-07-25 19:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:00:02 UTC to 2016-07-25 20:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:20:02 UTC to 2016-07-25 20:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 20:40:02 UTC to 2016-07-25 20:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:00:02 UTC to 2016-07-25 21:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:20:02 UTC to 2016-07-25 21:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 21:40:02 UTC to 2016-07-25 21:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:00:02 UTC to 2016-07-25 22:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:20:02 UTC to 2016-07-25 22:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 22:40:02 UTC to 2016-07-25 22:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:00:02 UTC to 2016-07-25 23:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:20:02 UTC to 2016-07-25 23:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-25 23:40:02 UTC to 2016-07-25 23:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:00:02 UTC to 2016-07-26 00:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:20:02 UTC to 2016-07-26 00:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 00:40:02 UTC to 2016-07-26 00:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:00:02 UTC to 2016-07-26 01:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:20:02 UTC to 2016-07-26 01:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 01:40:02 UTC to 2016-07-26 01:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:00:02 UTC to 2016-07-26 02:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:20:02 UTC to 2016-07-26 02:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 02:40:02 UTC to 2016-07-26 02:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:00:02 UTC to 2016-07-26 03:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:20:02 UTC to 2016-07-26 03:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 03:40:02 UTC to 2016-07-26 03:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:00:02 UTC to 2016-07-26 04:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:20:02 UTC to 2016-07-26 04:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 04:40:02 UTC to 2016-07-26 04:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:00:02 UTC to 2016-07-26 05:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:20:02 UTC to 2016-07-26 05:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 05:40:02 UTC to 2016-07-26 05:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:00:02 UTC to 2016-07-26 06:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:20:02 UTC to 2016-07-26 06:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 06:40:02 UTC to 2016-07-26 06:40:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 07:00:02 UTC to 2016-07-26 07:00:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-26 07:20:02 UTC to 2016-07-26 07:20:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 15:37:03 UTC to 2016-07-28 15:37:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 15:47:03 UTC to 2016-07-28 15:47:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:07:03 UTC to 2016-07-28 16:07:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:27:03 UTC to 2016-07-28 16:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 16:47:02 UTC to 2016-07-28 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:07:02 UTC to 2016-07-28 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:27:02 UTC to 2016-07-28 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 17:47:02 UTC to 2016-07-28 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:07:02 UTC to 2016-07-28 18:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:27:03 UTC to 2016-07-28 18:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 18:47:02 UTC to 2016-07-28 18:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:07:02 UTC to 2016-07-28 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:27:02 UTC to 2016-07-28 19:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 19:47:02 UTC to 2016-07-28 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:07:02 UTC to 2016-07-28 20:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:27:02 UTC to 2016-07-28 20:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 20:47:02 UTC to 2016-07-28 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:07:02 UTC to 2016-07-28 21:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:27:02 UTC to 2016-07-28 21:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 21:47:02 UTC to 2016-07-28 21:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:07:02 UTC to 2016-07-28 22:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:27:03 UTC to 2016-07-28 22:27:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 22:47:02 UTC to 2016-07-28 22:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:07:02 UTC to 2016-07-28 23:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:27:02 UTC to 2016-07-28 23:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-28 23:47:02 UTC to 2016-07-28 23:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:07:02 UTC to 2016-07-29 00:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:27:02 UTC to 2016-07-29 00:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 00:47:02 UTC to 2016-07-29 00:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:07:02 UTC to 2016-07-29 01:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:27:02 UTC to 2016-07-29 01:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 01:47:03 UTC to 2016-07-29 01:47:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:07:02 UTC to 2016-07-29 02:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:27:02 UTC to 2016-07-29 02:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 02:47:02 UTC to 2016-07-29 02:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:07:02 UTC to 2016-07-29 03:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:27:02 UTC to 2016-07-29 03:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 03:47:02 UTC to 2016-07-29 03:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:07:02 UTC to 2016-07-29 04:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:27:02 UTC to 2016-07-29 04:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 04:47:02 UTC to 2016-07-29 04:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:07:02 UTC to 2016-07-29 05:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:27:02 UTC to 2016-07-29 05:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 05:47:02 UTC to 2016-07-29 05:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:07:02 UTC to 2016-07-29 06:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:27:02 UTC to 2016-07-29 06:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 06:47:02 UTC to 2016-07-29 06:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:07:02 UTC to 2016-07-29 07:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:27:02 UTC to 2016-07-29 07:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 07:47:02 UTC to 2016-07-29 07:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:07:02 UTC to 2016-07-29 08:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:27:02 UTC to 2016-07-29 08:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 08:47:02 UTC to 2016-07-29 08:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:07:02 UTC to 2016-07-29 09:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:27:02 UTC to 2016-07-29 09:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 09:47:02 UTC to 2016-07-29 09:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:07:02 UTC to 2016-07-29 10:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:27:02 UTC to 2016-07-29 10:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 10:47:02 UTC to 2016-07-29 10:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:07:02 UTC to 2016-07-29 11:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:27:02 UTC to 2016-07-29 11:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 11:47:02 UTC to 2016-07-29 11:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:07:02 UTC to 2016-07-29 12:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:27:02 UTC to 2016-07-29 12:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 12:47:02 UTC to 2016-07-29 12:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:07:02 UTC to 2016-07-29 13:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:27:02 UTC to 2016-07-29 13:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 13:47:02 UTC to 2016-07-29 13:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:07:02 UTC to 2016-07-29 14:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:27:02 UTC to 2016-07-29 14:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 14:47:02 UTC to 2016-07-29 14:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:07:02 UTC to 2016-07-29 15:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:27:02 UTC to 2016-07-29 15:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 15:47:02 UTC to 2016-07-29 15:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:07:02 UTC to 2016-07-29 16:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:27:02 UTC to 2016-07-29 16:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 16:47:02 UTC to 2016-07-29 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:07:02 UTC to 2016-07-29 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:27:02 UTC to 2016-07-29 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 17:47:02 UTC to 2016-07-29 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:07:02 UTC to 2016-07-29 18:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:27:02 UTC to 2016-07-29 18:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 18:47:01 UTC to 2016-07-29 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:07:02 UTC to 2016-07-29 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:27:01 UTC to 2016-07-29 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 19:47:02 UTC to 2016-07-29 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:07:01 UTC to 2016-07-29 20:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:27:01 UTC to 2016-07-29 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 20:47:02 UTC to 2016-07-29 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:07:01 UTC to 2016-07-29 21:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:27:01 UTC to 2016-07-29 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 21:47:01 UTC to 2016-07-29 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:07:01 UTC to 2016-07-29 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:27:02 UTC to 2016-07-29 22:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 22:47:01 UTC to 2016-07-29 22:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:07:01 UTC to 2016-07-29 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:27:01 UTC to 2016-07-29 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-29 23:47:01 UTC to 2016-07-29 23:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:07:01 UTC to 2016-07-30 00:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:27:01 UTC to 2016-07-30 00:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 00:47:01 UTC to 2016-07-30 00:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:07:01 UTC to 2016-07-30 01:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:27:01 UTC to 2016-07-30 01:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 01:47:01 UTC to 2016-07-30 01:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:07:01 UTC to 2016-07-30 02:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:27:01 UTC to 2016-07-30 02:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 02:47:01 UTC to 2016-07-30 02:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:07:01 UTC to 2016-07-30 03:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:27:01 UTC to 2016-07-30 03:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 03:47:01 UTC to 2016-07-30 03:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:07:01 UTC to 2016-07-30 04:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:27:01 UTC to 2016-07-30 04:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 04:47:01 UTC to 2016-07-30 04:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:07:01 UTC to 2016-07-30 05:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:27:01 UTC to 2016-07-30 05:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 05:47:01 UTC to 2016-07-30 05:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:07:01 UTC to 2016-07-30 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:27:01 UTC to 2016-07-30 06:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 06:47:01 UTC to 2016-07-30 06:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:07:01 UTC to 2016-07-30 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:27:01 UTC to 2016-07-30 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 07:47:01 UTC to 2016-07-30 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:07:01 UTC to 2016-07-30 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:27:01 UTC to 2016-07-30 08:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 08:47:01 UTC to 2016-07-30 08:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:07:01 UTC to 2016-07-30 09:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:27:01 UTC to 2016-07-30 09:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 09:47:01 UTC to 2016-07-30 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:07:01 UTC to 2016-07-30 10:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:27:01 UTC to 2016-07-30 10:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 10:47:01 UTC to 2016-07-30 10:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:07:01 UTC to 2016-07-30 11:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:27:01 UTC to 2016-07-30 11:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 11:47:01 UTC to 2016-07-30 11:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:07:01 UTC to 2016-07-30 12:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:27:01 UTC to 2016-07-30 12:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 12:47:01 UTC to 2016-07-30 12:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:07:01 UTC to 2016-07-30 13:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:27:01 UTC to 2016-07-30 13:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 13:47:01 UTC to 2016-07-30 13:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:07:01 UTC to 2016-07-30 14:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:27:01 UTC to 2016-07-30 14:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 14:47:01 UTC to 2016-07-30 14:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:07:01 UTC to 2016-07-30 15:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:27:01 UTC to 2016-07-30 15:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 15:47:01 UTC to 2016-07-30 15:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:07:01 UTC to 2016-07-30 16:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:27:01 UTC to 2016-07-30 16:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 16:47:01 UTC to 2016-07-30 16:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:07:01 UTC to 2016-07-30 17:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:27:01 UTC to 2016-07-30 17:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 17:47:01 UTC to 2016-07-30 17:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:07:01 UTC to 2016-07-30 18:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:27:01 UTC to 2016-07-30 18:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 18:47:01 UTC to 2016-07-30 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:07:01 UTC to 2016-07-30 19:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:27:01 UTC to 2016-07-30 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 19:47:01 UTC to 2016-07-30 19:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:07:00 UTC to 2016-07-30 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:27:01 UTC to 2016-07-30 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 20:47:01 UTC to 2016-07-30 20:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:07:00 UTC to 2016-07-30 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:27:01 UTC to 2016-07-30 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 21:47:01 UTC to 2016-07-30 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:07:01 UTC to 2016-07-30 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:27:00 UTC to 2016-07-30 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 22:47:00 UTC to 2016-07-30 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:07:01 UTC to 2016-07-30 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:27:01 UTC to 2016-07-30 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-30 23:47:00 UTC to 2016-07-30 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:07:00 UTC to 2016-07-31 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:27:00 UTC to 2016-07-31 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 00:47:00 UTC to 2016-07-31 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:07:00 UTC to 2016-07-31 01:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:27:00 UTC to 2016-07-31 01:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 01:47:00 UTC to 2016-07-31 01:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:07:00 UTC to 2016-07-31 02:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:27:00 UTC to 2016-07-31 02:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 02:47:00 UTC to 2016-07-31 02:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:07:00 UTC to 2016-07-31 03:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:27:00 UTC to 2016-07-31 03:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 03:47:00 UTC to 2016-07-31 03:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:07:00 UTC to 2016-07-31 04:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:27:00 UTC to 2016-07-31 04:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 04:47:00 UTC to 2016-07-31 04:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:07:00 UTC to 2016-07-31 05:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:27:00 UTC to 2016-07-31 05:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 05:47:00 UTC to 2016-07-31 05:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:07:00 UTC to 2016-07-31 06:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:27:00 UTC to 2016-07-31 06:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 06:47:00 UTC to 2016-07-31 06:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:07:00 UTC to 2016-07-31 07:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:27:00 UTC to 2016-07-31 07:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 07:47:00 UTC to 2016-07-31 07:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:07:00 UTC to 2016-07-31 08:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:27:00 UTC to 2016-07-31 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 08:47:00 UTC to 2016-07-31 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:07:00 UTC to 2016-07-31 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:27:00 UTC to 2016-07-31 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 09:47:00 UTC to 2016-07-31 09:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:07:00 UTC to 2016-07-31 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:27:00 UTC to 2016-07-31 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 10:47:00 UTC to 2016-07-31 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:07:00 UTC to 2016-07-31 11:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:27:00 UTC to 2016-07-31 11:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 11:47:00 UTC to 2016-07-31 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:07:00 UTC to 2016-07-31 12:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:27:00 UTC to 2016-07-31 12:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 12:47:00 UTC to 2016-07-31 12:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:07:00 UTC to 2016-07-31 13:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:27:00 UTC to 2016-07-31 13:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 13:47:00 UTC to 2016-07-31 13:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:07:00 UTC to 2016-07-31 14:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:27:00 UTC to 2016-07-31 14:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 14:47:00 UTC to 2016-07-31 14:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:07:00 UTC to 2016-07-31 15:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:27:00 UTC to 2016-07-31 15:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 15:47:00 UTC to 2016-07-31 15:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:07:00 UTC to 2016-07-31 16:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:27:00 UTC to 2016-07-31 16:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 16:47:00 UTC to 2016-07-31 16:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:07:00 UTC to 2016-07-31 17:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:27:00 UTC to 2016-07-31 17:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 17:47:00 UTC to 2016-07-31 17:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:07:00 UTC to 2016-07-31 18:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:27:00 UTC to 2016-07-31 18:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 18:47:00 UTC to 2016-07-31 18:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:07:00 UTC to 2016-07-31 19:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:27:00 UTC to 2016-07-31 19:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 19:47:00 UTC to 2016-07-31 19:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:07:00 UTC to 2016-07-31 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:27:00 UTC to 2016-07-31 20:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 20:47:00 UTC to 2016-07-31 20:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:07:00 UTC to 2016-07-31 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:27:00 UTC to 2016-07-31 21:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 21:47:00 UTC to 2016-07-31 21:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:07:00 UTC to 2016-07-31 22:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:27:00 UTC to 2016-07-31 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 22:47:00 UTC to 2016-07-31 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:07:00 UTC to 2016-07-31 23:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:26:59 UTC to 2016-07-31 23:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-07-31 23:47:00 UTC to 2016-07-31 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:07:00 UTC to 2016-08-01 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:27:00 UTC to 2016-08-01 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 00:47:00 UTC to 2016-08-01 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:06:59 UTC to 2016-08-01 01:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:26:59 UTC to 2016-08-01 01:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 01:46:59 UTC to 2016-08-01 01:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:06:59 UTC to 2016-08-01 02:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:26:59 UTC to 2016-08-01 02:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 02:46:59 UTC to 2016-08-01 02:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 03:06:59 UTC to 2016-08-01 03:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-01 03:26:59 UTC to 2016-08-01 03:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-08-02 14:32:57 UTC to 2016-08-02 14:33:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 14:42:57 UTC to 2016-08-02 14:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 14:52:57 UTC to 2016-08-02 14:53:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:02:57 UTC to 2016-08-02 15:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:22:57 UTC to 2016-08-02 15:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:42:57 UTC to 2016-08-02 15:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:02:57 UTC to 2016-08-02 16:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:22:57 UTC to 2016-08-02 16:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:42:57 UTC to 2016-08-02 16:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:02:57 UTC to 2016-08-02 17:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:22:57 UTC to 2016-08-02 17:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:42:57 UTC to 2016-08-02 17:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:02:57 UTC to 2016-08-02 18:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:22:57 UTC to 2016-08-02 18:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:42:57 UTC to 2016-08-02 18:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:02:57 UTC to 2016-08-02 19:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:22:57 UTC to 2016-08-02 19:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:42:57 UTC to 2016-08-02 19:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:02:57 UTC to 2016-08-02 20:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:22:57 UTC to 2016-08-02 20:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:42:57 UTC to 2016-08-02 20:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:02:57 UTC to 2016-08-02 21:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:22:57 UTC to 2016-08-02 21:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:42:56 UTC to 2016-08-02 21:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:02:56 UTC to 2016-08-02 22:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:22:56 UTC to 2016-08-02 22:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:42:56 UTC to 2016-08-02 22:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:02:57 UTC to 2016-08-02 23:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:22:56 UTC to 2016-08-02 23:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:42:56 UTC to 2016-08-02 23:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:02:56 UTC to 2016-08-03 00:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:22:56 UTC to 2016-08-03 00:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:42:56 UTC to 2016-08-03 00:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:02:56 UTC to 2016-08-03 01:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:22:56 UTC to 2016-08-03 01:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:42:56 UTC to 2016-08-03 01:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:02:56 UTC to 2016-08-03 02:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:22:56 UTC to 2016-08-03 02:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:42:56 UTC to 2016-08-03 02:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:02:56 UTC to 2016-08-03 03:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:22:56 UTC to 2016-08-03 03:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:42:56 UTC to 2016-08-03 03:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:02:56 UTC to 2016-08-03 04:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:22:56 UTC to 2016-08-03 04:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:42:56 UTC to 2016-08-03 04:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:02:56 UTC to 2016-08-03 05:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:22:56 UTC to 2016-08-03 05:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:42:56 UTC to 2016-08-03 05:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:02:56 UTC to 2016-08-03 06:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:22:56 UTC to 2016-08-03 06:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:42:56 UTC to 2016-08-03 06:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:02:56 UTC to 2016-08-03 07:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:22:56 UTC to 2016-08-03 07:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:42:56 UTC to 2016-08-03 07:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:02:56 UTC to 2016-08-03 08:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:22:56 UTC to 2016-08-03 08:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:42:56 UTC to 2016-08-03 08:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:02:56 UTC to 2016-08-03 09:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:22:56 UTC to 2016-08-03 09:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:42:56 UTC to 2016-08-03 09:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:02:56 UTC to 2016-08-03 10:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:22:56 UTC to 2016-08-03 10:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:42:56 UTC to 2016-08-03 10:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:02:56 UTC to 2016-08-03 11:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:22:56 UTC to 2016-08-03 11:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:42:56 UTC to 2016-08-03 11:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:02:56 UTC to 2016-08-03 12:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:22:56 UTC to 2016-08-03 12:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:42:56 UTC to 2016-08-03 12:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:02:56 UTC to 2016-08-03 13:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:22:56 UTC to 2016-08-03 13:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:42:56 UTC to 2016-08-03 13:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:02:56 UTC to 2016-08-03 14:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:22:56 UTC to 2016-08-03 14:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:42:56 UTC to 2016-08-03 14:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:02:56 UTC to 2016-08-03 15:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:22:56 UTC to 2016-08-03 15:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:42:56 UTC to 2016-08-03 15:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:02:56 UTC to 2016-08-03 16:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:22:56 UTC to 2016-08-03 16:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:42:56 UTC to 2016-08-03 16:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:02:56 UTC to 2016-08-03 17:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:22:56 UTC to 2016-08-03 17:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:42:56 UTC to 2016-08-03 17:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:02:56 UTC to 2016-08-03 18:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:22:56 UTC to 2016-08-03 18:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:42:56 UTC to 2016-08-03 18:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:02:56 UTC to 2016-08-03 19:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:22:56 UTC to 2016-08-03 19:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:42:56 UTC to 2016-08-03 19:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:02:56 UTC to 2016-08-03 20:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:22:56 UTC to 2016-08-03 20:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:42:56 UTC to 2016-08-03 20:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:02:56 UTC to 2016-08-03 21:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:22:56 UTC to 2016-08-03 21:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:42:56 UTC to 2016-08-03 21:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:02:56 UTC to 2016-08-03 22:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:22:56 UTC to 2016-08-03 22:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:42:56 UTC to 2016-08-03 22:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:02:55 UTC to 2016-08-03 23:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:22:55 UTC to 2016-08-03 23:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:42:55 UTC to 2016-08-03 23:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:02:56 UTC to 2016-08-04 00:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:22:55 UTC to 2016-08-04 00:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:42:56 UTC to 2016-08-04 00:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:02:55 UTC to 2016-08-04 01:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:22:55 UTC to 2016-08-04 01:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:42:55 UTC to 2016-08-04 01:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:02:55 UTC to 2016-08-04 02:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:22:56 UTC to 2016-08-04 02:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:42:55 UTC to 2016-08-04 02:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:02:55 UTC to 2016-08-04 03:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:22:55 UTC to 2016-08-04 03:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:42:55 UTC to 2016-08-04 03:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:02:55 UTC to 2016-08-04 04:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:22:55 UTC to 2016-08-04 04:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:42:55 UTC to 2016-08-04 04:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:02:55 UTC to 2016-08-04 05:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:22:55 UTC to 2016-08-04 05:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:42:55 UTC to 2016-08-04 05:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:02:55 UTC to 2016-08-04 06:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:22:55 UTC to 2016-08-04 06:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:42:55 UTC to 2016-08-04 06:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:02:55 UTC to 2016-08-04 07:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:22:55 UTC to 2016-08-04 07:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:42:55 UTC to 2016-08-04 07:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:02:55 UTC to 2016-08-04 08:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:22:55 UTC to 2016-08-04 08:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:42:55 UTC to 2016-08-04 08:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:02:55 UTC to 2016-08-04 09:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:22:55 UTC to 2016-08-04 09:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:42:55 UTC to 2016-08-04 09:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:02:55 UTC to 2016-08-04 10:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:22:55 UTC to 2016-08-04 10:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:42:55 UTC to 2016-08-04 10:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:02:55 UTC to 2016-08-04 11:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:22:55 UTC to 2016-08-04 11:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:42:55 UTC to 2016-08-04 11:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:02:55 UTC to 2016-08-04 12:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:22:55 UTC to 2016-08-04 12:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:42:55 UTC to 2016-08-04 12:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:02:55 UTC to 2016-08-04 13:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:22:55 UTC to 2016-08-04 13:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:42:55 UTC to 2016-08-04 13:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 14:02:55 UTC to 2016-08-04 14:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:02:55 UTC to 2016-08-04 15:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:22:55 UTC to 2016-08-04 15:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:42:55 UTC to 2016-08-04 15:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:02:55 UTC to 2016-08-04 16:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:22:55 UTC to 2016-08-04 16:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:42:55 UTC to 2016-08-04 16:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:02:55 UTC to 2016-08-04 17:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:22:55 UTC to 2016-08-04 17:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:42:55 UTC to 2016-08-04 17:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:02:55 UTC to 2016-08-04 18:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:22:55 UTC to 2016-08-04 18:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:42:55 UTC to 2016-08-04 18:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:02:55 UTC to 2016-08-04 19:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:22:55 UTC to 2016-08-04 19:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:42:55 UTC to 2016-08-04 19:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:02:55 UTC to 2016-08-04 20:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:22:55 UTC to 2016-08-04 20:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:42:55 UTC to 2016-08-04 20:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:02:56 UTC to 2016-08-04 21:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:22:55 UTC to 2016-08-04 21:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:42:55 UTC to 2016-08-04 21:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:02:55 UTC to 2016-08-04 22:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:22:55 UTC to 2016-08-04 22:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:42:55 UTC to 2016-08-04 22:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:02:57 UTC to 2016-08-04 23:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:22:56 UTC to 2016-08-04 23:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:42:55 UTC to 2016-08-04 23:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:02:55 UTC to 2016-08-05 00:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:22:55 UTC to 2016-08-05 00:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:42:55 UTC to 2016-08-05 00:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:02:55 UTC to 2016-08-05 01:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:22:55 UTC to 2016-08-05 01:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:42:55 UTC to 2016-08-05 01:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:02:55 UTC to 2016-08-05 02:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:22:55 UTC to 2016-08-05 02:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:42:55 UTC to 2016-08-05 02:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:02:55 UTC to 2016-08-05 03:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:22:54 UTC to 2016-08-05 03:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:42:54 UTC to 2016-08-05 03:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:02:54 UTC to 2016-08-05 04:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:22:54 UTC to 2016-08-05 04:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:42:54 UTC to 2016-08-05 04:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:02:54 UTC to 2016-08-05 05:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:22:54 UTC to 2016-08-05 05:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:42:54 UTC to 2016-08-05 05:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:02:54 UTC to 2016-08-05 06:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:22:54 UTC to 2016-08-05 06:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:42:54 UTC to 2016-08-05 06:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:02:54 UTC to 2016-08-05 07:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:22:54 UTC to 2016-08-05 07:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:42:54 UTC to 2016-08-05 07:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:02:54 UTC to 2016-08-05 08:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:22:54 UTC to 2016-08-05 08:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:42:54 UTC to 2016-08-05 08:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 09:02:54 UTC to 2016-08-05 09:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 09:22:54 UTC to 2016-08-05 09:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:05:28 UTC to 2016-08-05 23:05:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:15:30 UTC to 2016-08-05 23:15:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:35:28 UTC to 2016-08-05 23:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:55:28 UTC to 2016-08-05 23:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:15:28 UTC to 2016-08-06 00:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:35:28 UTC to 2016-08-06 00:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:55:28 UTC to 2016-08-06 00:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:15:28 UTC to 2016-08-06 01:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:35:28 UTC to 2016-08-06 01:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:55:28 UTC to 2016-08-06 01:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:15:28 UTC to 2016-08-06 02:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:35:28 UTC to 2016-08-06 02:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:55:28 UTC to 2016-08-06 02:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:15:28 UTC to 2016-08-06 03:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:35:28 UTC to 2016-08-06 03:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:55:28 UTC to 2016-08-06 03:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:15:28 UTC to 2016-08-06 04:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:35:28 UTC to 2016-08-06 04:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:55:28 UTC to 2016-08-06 04:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:15:28 UTC to 2016-08-06 05:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:35:28 UTC to 2016-08-06 05:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:55:28 UTC to 2016-08-06 05:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:15:28 UTC to 2016-08-06 06:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:35:28 UTC to 2016-08-06 06:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:55:28 UTC to 2016-08-06 06:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:15:28 UTC to 2016-08-06 07:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:35:28 UTC to 2016-08-06 07:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:55:28 UTC to 2016-08-06 07:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:15:28 UTC to 2016-08-06 08:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:35:27 UTC to 2016-08-06 08:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:55:28 UTC to 2016-08-06 08:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:15:28 UTC to 2016-08-06 09:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:35:27 UTC to 2016-08-06 09:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:55:27 UTC to 2016-08-06 09:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:15:27 UTC to 2016-08-06 10:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:35:27 UTC to 2016-08-06 10:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:55:27 UTC to 2016-08-06 10:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:15:28 UTC to 2016-08-06 11:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:35:27 UTC to 2016-08-06 11:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:55:27 UTC to 2016-08-06 11:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:15:27 UTC to 2016-08-06 12:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:35:27 UTC to 2016-08-06 12:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:55:27 UTC to 2016-08-06 12:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:15:27 UTC to 2016-08-06 13:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:35:27 UTC to 2016-08-06 13:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:55:27 UTC to 2016-08-06 13:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:15:27 UTC to 2016-08-06 14:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:35:27 UTC to 2016-08-06 14:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:55:27 UTC to 2016-08-06 14:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:15:27 UTC to 2016-08-06 15:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:35:27 UTC to 2016-08-06 15:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:55:27 UTC to 2016-08-06 15:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:15:27 UTC to 2016-08-06 16:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:35:27 UTC to 2016-08-06 16:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:55:27 UTC to 2016-08-06 16:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:15:27 UTC to 2016-08-06 17:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:35:27 UTC to 2016-08-06 17:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:55:27 UTC to 2016-08-06 17:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:15:27 UTC to 2016-08-06 18:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:35:27 UTC to 2016-08-06 18:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:55:27 UTC to 2016-08-06 18:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:15:27 UTC to 2016-08-06 19:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:35:27 UTC to 2016-08-06 19:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:55:27 UTC to 2016-08-06 19:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:15:27 UTC to 2016-08-06 20:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:35:27 UTC to 2016-08-06 20:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:55:27 UTC to 2016-08-06 20:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:15:27 UTC to 2016-08-06 21:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:35:27 UTC to 2016-08-06 21:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:55:27 UTC to 2016-08-06 21:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:15:27 UTC to 2016-08-06 22:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:35:27 UTC to 2016-08-06 22:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:55:27 UTC to 2016-08-06 22:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:15:27 UTC to 2016-08-06 23:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:35:27 UTC to 2016-08-06 23:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:55:27 UTC to 2016-08-06 23:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:15:27 UTC to 2016-08-07 00:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:35:27 UTC to 2016-08-07 00:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:55:27 UTC to 2016-08-07 00:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:15:27 UTC to 2016-08-07 01:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:35:27 UTC to 2016-08-07 01:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:55:27 UTC to 2016-08-07 01:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:15:27 UTC to 2016-08-07 02:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:35:27 UTC to 2016-08-07 02:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:55:27 UTC to 2016-08-07 02:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:15:27 UTC to 2016-08-07 03:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:35:27 UTC to 2016-08-07 03:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:55:27 UTC to 2016-08-07 03:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:15:27 UTC to 2016-08-07 04:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:35:27 UTC to 2016-08-07 04:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:55:27 UTC to 2016-08-07 04:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:15:27 UTC to 2016-08-07 05:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:35:27 UTC to 2016-08-07 05:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:55:27 UTC to 2016-08-07 05:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:15:27 UTC to 2016-08-07 06:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:35:27 UTC to 2016-08-07 06:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:55:27 UTC to 2016-08-07 06:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:15:27 UTC to 2016-08-07 07:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:35:27 UTC to 2016-08-07 07:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:55:27 UTC to 2016-08-07 07:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:15:27 UTC to 2016-08-07 08:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:35:27 UTC to 2016-08-07 08:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:55:27 UTC to 2016-08-07 08:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:15:27 UTC to 2016-08-07 09:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:35:27 UTC to 2016-08-07 09:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:55:27 UTC to 2016-08-07 09:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:15:27 UTC to 2016-08-07 10:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:35:27 UTC to 2016-08-07 10:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:55:27 UTC to 2016-08-07 10:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:15:27 UTC to 2016-08-07 11:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:35:27 UTC to 2016-08-07 11:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:55:27 UTC to 2016-08-07 11:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:15:27 UTC to 2016-08-07 12:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:35:27 UTC to 2016-08-07 12:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:55:27 UTC to 2016-08-07 12:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:15:27 UTC to 2016-08-07 13:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:35:26 UTC to 2016-08-07 13:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:55:26 UTC to 2016-08-07 13:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:15:26 UTC to 2016-08-07 14:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:35:26 UTC to 2016-08-07 14:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:55:26 UTC to 2016-08-07 14:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:15:26 UTC to 2016-08-07 15:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:35:27 UTC to 2016-08-07 15:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:55:26 UTC to 2016-08-07 15:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:15:26 UTC to 2016-08-07 16:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:35:26 UTC to 2016-08-07 16:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:55:26 UTC to 2016-08-07 16:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:15:26 UTC to 2016-08-07 17:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:35:26 UTC to 2016-08-07 17:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:55:26 UTC to 2016-08-07 17:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:15:26 UTC to 2016-08-07 18:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:35:26 UTC to 2016-08-07 18:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:55:26 UTC to 2016-08-07 18:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:15:26 UTC to 2016-08-07 19:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:35:26 UTC to 2016-08-07 19:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:55:26 UTC to 2016-08-07 19:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:15:26 UTC to 2016-08-07 20:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:35:26 UTC to 2016-08-07 20:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:55:26 UTC to 2016-08-07 20:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:15:26 UTC to 2016-08-07 21:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:35:26 UTC to 2016-08-07 21:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:55:26 UTC to 2016-08-07 21:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:15:26 UTC to 2016-08-07 22:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:35:26 UTC to 2016-08-07 22:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:55:26 UTC to 2016-08-07 22:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:15:26 UTC to 2016-08-07 23:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:35:26 UTC to 2016-08-07 23:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:55:26 UTC to 2016-08-07 23:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:15:26 UTC to 2016-08-08 00:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:35:26 UTC to 2016-08-08 00:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:55:26 UTC to 2016-08-08 00:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:15:26 UTC to 2016-08-08 01:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:35:26 UTC to 2016-08-08 01:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:55:26 UTC to 2016-08-08 01:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:15:26 UTC to 2016-08-08 02:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:35:26 UTC to 2016-08-08 02:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:55:26 UTC to 2016-08-08 02:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:15:26 UTC to 2016-08-08 03:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:35:26 UTC to 2016-08-08 03:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:55:26 UTC to 2016-08-08 03:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:15:26 UTC to 2016-08-08 04:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:35:26 UTC to 2016-08-08 04:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:55:26 UTC to 2016-08-08 04:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:15:26 UTC to 2016-08-08 05:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:35:26 UTC to 2016-08-08 05:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:55:26 UTC to 2016-08-08 05:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:15:26 UTC to 2016-08-08 06:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:35:26 UTC to 2016-08-08 06:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:55:26 UTC to 2016-08-08 06:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 07:15:26 UTC to 2016-08-08 07:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 07:35:26 UTC to 2016-08-08 07:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:19:04 UTC to 2016-08-09 20:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:39:04 UTC to 2016-08-09 20:39:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:59:04 UTC to 2016-08-09 20:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:19:04 UTC to 2016-08-09 21:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:39:04 UTC to 2016-08-09 21:39:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:59:04 UTC to 2016-08-09 21:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:19:03 UTC to 2016-08-09 22:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:39:03 UTC to 2016-08-09 22:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:59:03 UTC to 2016-08-09 22:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:19:03 UTC to 2016-08-09 23:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:39:03 UTC to 2016-08-09 23:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:59:04 UTC to 2016-08-09 23:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:19:03 UTC to 2016-08-10 00:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:39:03 UTC to 2016-08-10 00:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:59:03 UTC to 2016-08-10 00:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:19:04 UTC to 2016-08-10 01:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:39:03 UTC to 2016-08-10 01:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:59:03 UTC to 2016-08-10 01:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:19:03 UTC to 2016-08-10 02:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:39:03 UTC to 2016-08-10 02:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:59:03 UTC to 2016-08-10 02:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:19:03 UTC to 2016-08-10 03:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:39:03 UTC to 2016-08-10 03:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:59:03 UTC to 2016-08-10 03:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:19:03 UTC to 2016-08-10 04:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:39:03 UTC to 2016-08-10 04:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:59:03 UTC to 2016-08-10 04:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:19:03 UTC to 2016-08-10 05:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:39:03 UTC to 2016-08-10 05:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:59:03 UTC to 2016-08-10 05:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:19:03 UTC to 2016-08-10 06:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:39:03 UTC to 2016-08-10 06:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:59:03 UTC to 2016-08-10 06:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:19:03 UTC to 2016-08-10 07:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:39:03 UTC to 2016-08-10 07:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:59:03 UTC to 2016-08-10 07:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:19:03 UTC to 2016-08-10 08:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:39:03 UTC to 2016-08-10 08:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:59:03 UTC to 2016-08-10 08:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:19:03 UTC to 2016-08-10 09:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:39:03 UTC to 2016-08-10 09:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:59:03 UTC to 2016-08-10 09:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:19:03 UTC to 2016-08-10 10:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:39:03 UTC to 2016-08-10 10:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:59:03 UTC to 2016-08-10 10:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:19:03 UTC to 2016-08-10 11:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:39:03 UTC to 2016-08-10 11:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:59:03 UTC to 2016-08-10 11:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:19:03 UTC to 2016-08-10 12:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:39:03 UTC to 2016-08-10 12:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:59:03 UTC to 2016-08-10 12:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:19:03 UTC to 2016-08-10 13:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:39:03 UTC to 2016-08-10 13:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:59:03 UTC to 2016-08-10 13:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:19:03 UTC to 2016-08-10 14:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:39:03 UTC to 2016-08-10 14:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:59:03 UTC to 2016-08-10 14:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:19:03 UTC to 2016-08-10 15:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:39:03 UTC to 2016-08-10 15:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:59:03 UTC to 2016-08-10 15:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:19:03 UTC to 2016-08-10 16:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:39:03 UTC to 2016-08-10 16:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:59:03 UTC to 2016-08-10 16:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:19:03 UTC to 2016-08-10 17:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:39:03 UTC to 2016-08-10 17:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:59:03 UTC to 2016-08-10 17:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:19:03 UTC to 2016-08-10 18:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:39:03 UTC to 2016-08-10 18:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:59:03 UTC to 2016-08-10 18:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:19:03 UTC to 2016-08-10 19:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:39:03 UTC to 2016-08-10 19:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:59:03 UTC to 2016-08-10 19:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:19:03 UTC to 2016-08-10 20:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:39:03 UTC to 2016-08-10 20:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:59:03 UTC to 2016-08-10 20:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:19:03 UTC to 2016-08-10 21:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:39:03 UTC to 2016-08-10 21:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:59:03 UTC to 2016-08-10 21:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:19:03 UTC to 2016-08-10 22:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:39:03 UTC to 2016-08-10 22:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:59:03 UTC to 2016-08-10 22:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:19:03 UTC to 2016-08-10 23:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:39:03 UTC to 2016-08-10 23:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:59:03 UTC to 2016-08-10 23:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:19:03 UTC to 2016-08-11 00:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:39:03 UTC to 2016-08-11 00:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:59:03 UTC to 2016-08-11 00:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:19:03 UTC to 2016-08-11 01:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:39:03 UTC to 2016-08-11 01:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:59:02 UTC to 2016-08-11 01:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:19:02 UTC to 2016-08-11 02:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:39:02 UTC to 2016-08-11 02:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:59:03 UTC to 2016-08-11 02:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:19:02 UTC to 2016-08-11 03:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:39:02 UTC to 2016-08-11 03:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:59:03 UTC to 2016-08-11 03:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:19:02 UTC to 2016-08-11 04:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:39:02 UTC to 2016-08-11 04:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:59:02 UTC to 2016-08-11 04:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:19:02 UTC to 2016-08-11 05:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:39:02 UTC to 2016-08-11 05:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:59:02 UTC to 2016-08-11 05:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:19:02 UTC to 2016-08-11 06:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:39:02 UTC to 2016-08-11 06:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:59:02 UTC to 2016-08-11 06:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:19:02 UTC to 2016-08-11 07:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:39:02 UTC to 2016-08-11 07:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:59:02 UTC to 2016-08-11 07:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:19:02 UTC to 2016-08-11 08:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:39:02 UTC to 2016-08-11 08:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:59:02 UTC to 2016-08-11 08:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:19:02 UTC to 2016-08-11 09:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:39:02 UTC to 2016-08-11 09:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:59:02 UTC to 2016-08-11 09:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:19:02 UTC to 2016-08-11 10:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:39:02 UTC to 2016-08-11 10:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:59:02 UTC to 2016-08-11 10:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:19:02 UTC to 2016-08-11 11:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:39:02 UTC to 2016-08-11 11:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:59:02 UTC to 2016-08-11 11:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:19:02 UTC to 2016-08-11 12:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:39:02 UTC to 2016-08-11 12:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:59:02 UTC to 2016-08-11 12:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:19:02 UTC to 2016-08-11 13:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:39:02 UTC to 2016-08-11 13:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:59:02 UTC to 2016-08-11 13:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:19:02 UTC to 2016-08-11 14:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:39:02 UTC to 2016-08-11 14:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:59:02 UTC to 2016-08-11 14:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:19:02 UTC to 2016-08-11 15:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:39:02 UTC to 2016-08-11 15:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:59:02 UTC to 2016-08-11 15:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:19:02 UTC to 2016-08-11 16:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:39:02 UTC to 2016-08-11 16:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:59:02 UTC to 2016-08-11 16:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:19:02 UTC to 2016-08-11 17:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:39:02 UTC to 2016-08-11 17:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:59:02 UTC to 2016-08-11 17:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:19:02 UTC to 2016-08-11 18:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:39:02 UTC to 2016-08-11 18:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:59:02 UTC to 2016-08-11 18:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:19:02 UTC to 2016-08-11 19:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:39:02 UTC to 2016-08-11 19:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:59:02 UTC to 2016-08-11 19:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:19:02 UTC to 2016-08-11 20:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:39:02 UTC to 2016-08-11 20:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:59:02 UTC to 2016-08-11 20:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:19:02 UTC to 2016-08-11 21:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:39:02 UTC to 2016-08-11 21:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:59:02 UTC to 2016-08-11 21:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:19:02 UTC to 2016-08-11 22:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:39:02 UTC to 2016-08-11 22:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:59:02 UTC to 2016-08-11 22:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:19:02 UTC to 2016-08-11 23:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:39:02 UTC to 2016-08-11 23:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:59:02 UTC to 2016-08-11 23:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:19:02 UTC to 2016-08-12 00:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:39:02 UTC to 2016-08-12 00:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:59:02 UTC to 2016-08-12 00:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:19:02 UTC to 2016-08-12 01:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:39:02 UTC to 2016-08-12 01:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:59:02 UTC to 2016-08-12 01:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:19:02 UTC to 2016-08-12 02:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:39:02 UTC to 2016-08-12 02:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:59:02 UTC to 2016-08-12 02:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:19:02 UTC to 2016-08-12 03:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:39:01 UTC to 2016-08-12 03:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:59:02 UTC to 2016-08-12 03:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:19:01 UTC to 2016-08-12 04:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:39:01 UTC to 2016-08-12 04:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:59:01 UTC to 2016-08-12 04:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:19:01 UTC to 2016-08-12 05:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:39:01 UTC to 2016-08-12 05:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:59:01 UTC to 2016-08-12 05:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:19:01 UTC to 2016-08-12 06:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:39:01 UTC to 2016-08-12 06:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:59:01 UTC to 2016-08-12 06:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:19:01 UTC to 2016-08-12 07:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:39:01 UTC to 2016-08-12 07:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:59:01 UTC to 2016-08-12 07:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:19:01 UTC to 2016-08-12 08:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:39:01 UTC to 2016-08-12 08:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:59:01 UTC to 2016-08-12 08:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:19:01 UTC to 2016-08-12 09:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:39:01 UTC to 2016-08-12 09:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:59:01 UTC to 2016-08-12 09:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 10:19:01 UTC to 2016-08-12 10:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 10:39:01 UTC to 2016-08-12 10:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:00:31 UTC to 2016-08-13 00:00:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:10:30 UTC to 2016-08-13 00:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:30:31 UTC to 2016-08-13 00:30:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:50:30 UTC to 2016-08-13 00:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:10:30 UTC to 2016-08-13 01:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:30:31 UTC to 2016-08-13 01:30:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:50:30 UTC to 2016-08-13 01:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:10:31 UTC to 2016-08-13 02:10:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:30:30 UTC to 2016-08-13 02:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:50:30 UTC to 2016-08-13 02:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:10:30 UTC to 2016-08-13 03:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:30:30 UTC to 2016-08-13 03:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:50:30 UTC to 2016-08-13 03:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:10:30 UTC to 2016-08-13 04:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:30:30 UTC to 2016-08-13 04:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:50:30 UTC to 2016-08-13 04:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:10:30 UTC to 2016-08-13 05:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:30:30 UTC to 2016-08-13 05:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:50:30 UTC to 2016-08-13 05:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:10:30 UTC to 2016-08-13 06:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:30:30 UTC to 2016-08-13 06:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:50:30 UTC to 2016-08-13 06:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:10:30 UTC to 2016-08-13 07:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:30:30 UTC to 2016-08-13 07:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:50:30 UTC to 2016-08-13 07:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:10:30 UTC to 2016-08-13 08:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:30:30 UTC to 2016-08-13 08:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:50:30 UTC to 2016-08-13 08:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:10:30 UTC to 2016-08-13 09:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:30:30 UTC to 2016-08-13 09:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:50:30 UTC to 2016-08-13 09:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:10:30 UTC to 2016-08-13 10:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:30:30 UTC to 2016-08-13 10:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:50:30 UTC to 2016-08-13 10:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:10:30 UTC to 2016-08-13 11:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:30:30 UTC to 2016-08-13 11:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:50:30 UTC to 2016-08-13 11:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:10:30 UTC to 2016-08-13 12:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:30:30 UTC to 2016-08-13 12:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:50:30 UTC to 2016-08-13 12:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:10:30 UTC to 2016-08-13 13:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:30:30 UTC to 2016-08-13 13:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:50:30 UTC to 2016-08-13 13:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:10:30 UTC to 2016-08-13 14:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:30:30 UTC to 2016-08-13 14:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:50:30 UTC to 2016-08-13 14:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:10:30 UTC to 2016-08-13 15:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:30:30 UTC to 2016-08-13 15:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:50:30 UTC to 2016-08-13 15:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:10:30 UTC to 2016-08-13 16:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:30:30 UTC to 2016-08-13 16:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:50:30 UTC to 2016-08-13 16:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:10:30 UTC to 2016-08-13 17:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:30:30 UTC to 2016-08-13 17:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:50:30 UTC to 2016-08-13 17:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:10:30 UTC to 2016-08-13 18:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:30:30 UTC to 2016-08-13 18:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:50:30 UTC to 2016-08-13 18:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:10:30 UTC to 2016-08-13 19:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:30:30 UTC to 2016-08-13 19:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:50:30 UTC to 2016-08-13 19:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:10:30 UTC to 2016-08-13 20:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:30:30 UTC to 2016-08-13 20:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:50:30 UTC to 2016-08-13 20:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:10:30 UTC to 2016-08-13 21:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:30:30 UTC to 2016-08-13 21:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:50:30 UTC to 2016-08-13 21:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:10:30 UTC to 2016-08-13 22:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:30:30 UTC to 2016-08-13 22:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:50:30 UTC to 2016-08-13 22:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:10:30 UTC to 2016-08-13 23:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:30:30 UTC to 2016-08-13 23:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:50:30 UTC to 2016-08-13 23:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:10:30 UTC to 2016-08-14 00:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:30:30 UTC to 2016-08-14 00:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:50:30 UTC to 2016-08-14 00:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:10:30 UTC to 2016-08-14 01:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:30:30 UTC to 2016-08-14 01:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:50:30 UTC to 2016-08-14 01:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:10:29 UTC to 2016-08-14 02:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:30:30 UTC to 2016-08-14 02:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:50:30 UTC to 2016-08-14 02:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:10:30 UTC to 2016-08-14 03:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:30:30 UTC to 2016-08-14 03:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:50:30 UTC to 2016-08-14 03:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:10:30 UTC to 2016-08-14 04:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:30:30 UTC to 2016-08-14 04:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:50:29 UTC to 2016-08-14 04:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:10:29 UTC to 2016-08-14 05:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:30:29 UTC to 2016-08-14 05:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:50:29 UTC to 2016-08-14 05:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:10:29 UTC to 2016-08-14 06:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:30:29 UTC to 2016-08-14 06:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:50:30 UTC to 2016-08-14 06:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:10:29 UTC to 2016-08-14 07:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:30:29 UTC to 2016-08-14 07:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:50:29 UTC to 2016-08-14 07:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:10:29 UTC to 2016-08-14 08:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:30:29 UTC to 2016-08-14 08:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:50:29 UTC to 2016-08-14 08:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:10:29 UTC to 2016-08-14 09:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:30:29 UTC to 2016-08-14 09:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:50:29 UTC to 2016-08-14 09:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:10:29 UTC to 2016-08-14 10:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:30:29 UTC to 2016-08-14 10:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:50:29 UTC to 2016-08-14 10:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:10:29 UTC to 2016-08-14 11:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:30:29 UTC to 2016-08-14 11:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:50:29 UTC to 2016-08-14 11:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 19:36:09 UTC to 2016-08-15 19:36:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 19:46:09 UTC to 2016-08-15 19:46:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:06:09 UTC to 2016-08-15 20:06:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:26:09 UTC to 2016-08-15 20:26:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:46:08 UTC to 2016-08-15 20:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:06:08 UTC to 2016-08-15 21:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:26:08 UTC to 2016-08-15 21:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:46:08 UTC to 2016-08-15 21:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:06:08 UTC to 2016-08-15 22:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:26:08 UTC to 2016-08-15 22:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:46:08 UTC to 2016-08-15 22:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:06:08 UTC to 2016-08-15 23:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:26:12 UTC to 2016-08-15 23:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:46:09 UTC to 2016-08-15 23:46:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:06:08 UTC to 2016-08-16 00:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:26:08 UTC to 2016-08-16 00:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:46:08 UTC to 2016-08-16 00:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:06:08 UTC to 2016-08-16 01:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:26:08 UTC to 2016-08-16 01:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:46:08 UTC to 2016-08-16 01:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:06:08 UTC to 2016-08-16 02:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:26:08 UTC to 2016-08-16 02:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:46:08 UTC to 2016-08-16 02:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:06:08 UTC to 2016-08-16 03:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:26:08 UTC to 2016-08-16 03:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:46:08 UTC to 2016-08-16 03:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:06:08 UTC to 2016-08-16 04:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:26:08 UTC to 2016-08-16 04:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:46:08 UTC to 2016-08-16 04:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:06:08 UTC to 2016-08-16 05:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:26:08 UTC to 2016-08-16 05:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:46:08 UTC to 2016-08-16 05:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:06:08 UTC to 2016-08-16 06:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:26:08 UTC to 2016-08-16 06:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:46:08 UTC to 2016-08-16 06:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:06:08 UTC to 2016-08-16 07:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:26:08 UTC to 2016-08-16 07:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:46:08 UTC to 2016-08-16 07:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:06:08 UTC to 2016-08-16 08:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:26:08 UTC to 2016-08-16 08:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:46:08 UTC to 2016-08-16 08:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:06:08 UTC to 2016-08-16 09:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:26:08 UTC to 2016-08-16 09:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:46:08 UTC to 2016-08-16 09:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:06:08 UTC to 2016-08-16 10:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:26:08 UTC to 2016-08-16 10:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:46:08 UTC to 2016-08-16 10:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:06:08 UTC to 2016-08-16 11:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:26:08 UTC to 2016-08-16 11:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:46:08 UTC to 2016-08-16 11:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:06:08 UTC to 2016-08-16 12:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:26:08 UTC to 2016-08-16 12:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:46:08 UTC to 2016-08-16 12:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:06:08 UTC to 2016-08-16 13:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:26:08 UTC to 2016-08-16 13:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:46:08 UTC to 2016-08-16 13:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:06:08 UTC to 2016-08-16 14:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:26:08 UTC to 2016-08-16 14:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:46:08 UTC to 2016-08-16 14:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:06:08 UTC to 2016-08-16 15:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:26:08 UTC to 2016-08-16 15:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:46:08 UTC to 2016-08-16 15:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:06:08 UTC to 2016-08-16 16:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:26:08 UTC to 2016-08-16 16:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:46:08 UTC to 2016-08-16 16:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:06:08 UTC to 2016-08-16 17:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:26:08 UTC to 2016-08-16 17:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:46:08 UTC to 2016-08-16 17:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:06:08 UTC to 2016-08-16 18:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:26:08 UTC to 2016-08-16 18:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:46:08 UTC to 2016-08-16 18:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:06:08 UTC to 2016-08-16 19:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:26:08 UTC to 2016-08-16 19:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:46:08 UTC to 2016-08-16 19:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:06:08 UTC to 2016-08-16 20:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:26:08 UTC to 2016-08-16 20:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:46:08 UTC to 2016-08-16 20:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:06:08 UTC to 2016-08-16 21:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:26:08 UTC to 2016-08-16 21:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:46:08 UTC to 2016-08-16 21:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:06:08 UTC to 2016-08-16 22:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:26:08 UTC to 2016-08-16 22:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:46:08 UTC to 2016-08-16 22:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:06:09 UTC to 2016-08-16 23:06:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:26:08 UTC to 2016-08-16 23:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:46:08 UTC to 2016-08-16 23:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:06:07 UTC to 2016-08-17 00:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:26:07 UTC to 2016-08-17 00:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:46:07 UTC to 2016-08-17 00:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:06:07 UTC to 2016-08-17 01:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:26:07 UTC to 2016-08-17 01:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:46:07 UTC to 2016-08-17 01:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:06:08 UTC to 2016-08-17 02:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:26:07 UTC to 2016-08-17 02:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:46:07 UTC to 2016-08-17 02:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:06:07 UTC to 2016-08-17 03:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:26:07 UTC to 2016-08-17 03:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:46:07 UTC to 2016-08-17 03:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:06:07 UTC to 2016-08-17 04:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:26:07 UTC to 2016-08-17 04:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:46:07 UTC to 2016-08-17 04:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 05:06:07 UTC to 2016-08-17 05:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 23:32:11 UTC to 2016-08-17 23:32:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 23:42:11 UTC to 2016-08-17 23:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:02:11 UTC to 2016-08-18 00:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:22:11 UTC to 2016-08-18 00:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:42:11 UTC to 2016-08-18 00:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:02:11 UTC to 2016-08-18 01:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:22:11 UTC to 2016-08-18 01:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:42:11 UTC to 2016-08-18 01:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:02:11 UTC to 2016-08-18 02:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:22:11 UTC to 2016-08-18 02:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:42:11 UTC to 2016-08-18 02:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:02:11 UTC to 2016-08-18 03:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:22:11 UTC to 2016-08-18 03:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:42:11 UTC to 2016-08-18 03:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:02:11 UTC to 2016-08-18 04:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:22:11 UTC to 2016-08-18 04:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:42:11 UTC to 2016-08-18 04:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:02:11 UTC to 2016-08-18 05:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:22:11 UTC to 2016-08-18 05:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:42:11 UTC to 2016-08-18 05:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:02:11 UTC to 2016-08-18 06:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:22:11 UTC to 2016-08-18 06:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:42:11 UTC to 2016-08-18 06:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:02:11 UTC to 2016-08-18 07:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:22:11 UTC to 2016-08-18 07:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:42:11 UTC to 2016-08-18 07:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:02:11 UTC to 2016-08-18 08:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:22:11 UTC to 2016-08-18 08:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:42:11 UTC to 2016-08-18 08:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:02:11 UTC to 2016-08-18 09:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:22:11 UTC to 2016-08-18 09:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:42:11 UTC to 2016-08-18 09:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:02:11 UTC to 2016-08-18 10:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:22:11 UTC to 2016-08-18 10:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:42:11 UTC to 2016-08-18 10:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:02:11 UTC to 2016-08-18 11:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:22:11 UTC to 2016-08-18 11:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:42:11 UTC to 2016-08-18 11:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:02:11 UTC to 2016-08-18 12:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:22:11 UTC to 2016-08-18 12:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:42:11 UTC to 2016-08-18 12:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:02:11 UTC to 2016-08-18 13:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:22:11 UTC to 2016-08-18 13:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:42:11 UTC to 2016-08-18 13:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:02:11 UTC to 2016-08-18 14:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:22:11 UTC to 2016-08-18 14:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:42:11 UTC to 2016-08-18 14:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:02:11 UTC to 2016-08-18 15:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:22:11 UTC to 2016-08-18 15:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:42:11 UTC to 2016-08-18 15:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:02:11 UTC to 2016-08-18 16:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:22:11 UTC to 2016-08-18 16:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:42:12 UTC to 2016-08-18 16:42:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:02:11 UTC to 2016-08-18 17:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:22:11 UTC to 2016-08-18 17:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:42:11 UTC to 2016-08-18 17:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 18:02:11 UTC to 2016-08-18 18:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 18:22:11 UTC to 2016-08-18 18:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:02:11 UTC to 2016-08-18 19:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:22:11 UTC to 2016-08-18 19:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:42:11 UTC to 2016-08-18 19:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:02:10 UTC to 2016-08-18 20:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:22:11 UTC to 2016-08-18 20:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:42:10 UTC to 2016-08-18 20:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:02:11 UTC to 2016-08-18 21:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:22:10 UTC to 2016-08-18 21:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:42:10 UTC to 2016-08-18 21:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:02:10 UTC to 2016-08-18 22:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:22:11 UTC to 2016-08-18 22:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:42:10 UTC to 2016-08-18 22:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:02:10 UTC to 2016-08-18 23:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:22:10 UTC to 2016-08-18 23:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:42:10 UTC to 2016-08-18 23:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:02:10 UTC to 2016-08-19 00:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:22:10 UTC to 2016-08-19 00:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:42:10 UTC to 2016-08-19 00:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:02:10 UTC to 2016-08-19 01:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:22:11 UTC to 2016-08-19 01:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:42:10 UTC to 2016-08-19 01:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:02:10 UTC to 2016-08-19 02:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:22:10 UTC to 2016-08-19 02:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:42:10 UTC to 2016-08-19 02:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:02:10 UTC to 2016-08-19 03:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:22:10 UTC to 2016-08-19 03:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:42:10 UTC to 2016-08-19 03:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:02:10 UTC to 2016-08-19 04:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:22:10 UTC to 2016-08-19 04:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:42:10 UTC to 2016-08-19 04:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:02:10 UTC to 2016-08-19 05:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:22:10 UTC to 2016-08-19 05:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:42:10 UTC to 2016-08-19 05:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:02:10 UTC to 2016-08-19 06:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:22:10 UTC to 2016-08-19 06:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:42:10 UTC to 2016-08-19 06:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:02:10 UTC to 2016-08-19 07:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:22:10 UTC to 2016-08-19 07:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:42:10 UTC to 2016-08-19 07:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:02:10 UTC to 2016-08-19 08:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:22:10 UTC to 2016-08-19 08:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:42:10 UTC to 2016-08-19 08:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:02:10 UTC to 2016-08-19 09:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:22:10 UTC to 2016-08-19 09:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:42:10 UTC to 2016-08-19 09:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:02:10 UTC to 2016-08-19 10:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:22:10 UTC to 2016-08-19 10:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:42:10 UTC to 2016-08-19 10:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:02:10 UTC to 2016-08-19 11:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:22:10 UTC to 2016-08-19 11:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:42:10 UTC to 2016-08-19 11:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:02:10 UTC to 2016-08-19 12:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:22:10 UTC to 2016-08-19 12:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:42:10 UTC to 2016-08-19 12:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:02:10 UTC to 2016-08-19 13:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:22:11 UTC to 2016-08-19 13:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:42:13 UTC to 2016-08-19 13:42:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:02:10 UTC to 2016-08-19 14:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:22:10 UTC to 2016-08-19 14:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:42:10 UTC to 2016-08-19 14:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:02:10 UTC to 2016-08-19 15:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:22:10 UTC to 2016-08-19 15:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:42:10 UTC to 2016-08-19 15:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:02:10 UTC to 2016-08-19 16:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:22:10 UTC to 2016-08-19 16:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:42:10 UTC to 2016-08-19 16:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:02:10 UTC to 2016-08-19 17:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:22:10 UTC to 2016-08-19 17:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:42:10 UTC to 2016-08-19 17:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:02:10 UTC to 2016-08-19 18:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:22:10 UTC to 2016-08-19 18:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:42:10 UTC to 2016-08-19 18:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:02:10 UTC to 2016-08-19 19:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:22:10 UTC to 2016-08-19 19:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:42:10 UTC to 2016-08-19 19:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:02:10 UTC to 2016-08-19 20:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:22:10 UTC to 2016-08-19 20:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:42:10 UTC to 2016-08-19 20:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:02:12 UTC to 2016-08-19 21:02:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:22:10 UTC to 2016-08-19 21:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:42:10 UTC to 2016-08-19 21:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:02:10 UTC to 2016-08-19 22:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:22:10 UTC to 2016-08-19 22:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:42:09 UTC to 2016-08-19 22:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:02:09 UTC to 2016-08-19 23:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:22:10 UTC to 2016-08-19 23:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:42:09 UTC to 2016-08-19 23:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:02:09 UTC to 2016-08-20 00:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:22:09 UTC to 2016-08-20 00:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:42:10 UTC to 2016-08-20 00:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:02:09 UTC to 2016-08-20 01:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:22:09 UTC to 2016-08-20 01:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:42:09 UTC to 2016-08-20 01:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:02:09 UTC to 2016-08-20 02:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:22:10 UTC to 2016-08-20 02:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:42:09 UTC to 2016-08-20 02:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:02:09 UTC to 2016-08-20 03:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:22:10 UTC to 2016-08-20 03:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:42:09 UTC to 2016-08-20 03:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:02:09 UTC to 2016-08-20 04:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:22:09 UTC to 2016-08-20 04:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:42:10 UTC to 2016-08-20 04:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:02:09 UTC to 2016-08-20 05:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:22:09 UTC to 2016-08-20 05:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:42:09 UTC to 2016-08-20 05:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:02:09 UTC to 2016-08-20 06:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:22:09 UTC to 2016-08-20 06:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:42:09 UTC to 2016-08-20 06:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:02:09 UTC to 2016-08-20 07:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:22:09 UTC to 2016-08-20 07:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:42:09 UTC to 2016-08-20 07:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:02:09 UTC to 2016-08-20 08:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:22:09 UTC to 2016-08-20 08:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:42:09 UTC to 2016-08-20 08:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:02:09 UTC to 2016-08-20 09:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:22:09 UTC to 2016-08-20 09:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:42:09 UTC to 2016-08-20 09:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:02:09 UTC to 2016-08-20 10:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:22:09 UTC to 2016-08-20 10:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:42:09 UTC to 2016-08-20 10:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:02:09 UTC to 2016-08-20 11:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:22:09 UTC to 2016-08-20 11:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:42:09 UTC to 2016-08-20 11:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:02:09 UTC to 2016-08-20 12:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:22:09 UTC to 2016-08-20 12:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:42:09 UTC to 2016-08-20 12:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:02:09 UTC to 2016-08-20 13:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:22:09 UTC to 2016-08-20 13:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:42:09 UTC to 2016-08-20 13:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:02:09 UTC to 2016-08-20 14:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:22:09 UTC to 2016-08-20 14:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:42:09 UTC to 2016-08-20 14:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:02:09 UTC to 2016-08-20 15:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:22:09 UTC to 2016-08-20 15:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:42:09 UTC to 2016-08-20 15:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:02:09 UTC to 2016-08-20 16:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:22:09 UTC to 2016-08-20 16:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:42:09 UTC to 2016-08-20 16:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:02:09 UTC to 2016-08-20 17:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:22:09 UTC to 2016-08-20 17:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:42:09 UTC to 2016-08-20 17:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:02:09 UTC to 2016-08-20 18:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:22:09 UTC to 2016-08-20 18:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:42:09 UTC to 2016-08-20 18:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:02:09 UTC to 2016-08-20 19:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:22:09 UTC to 2016-08-20 19:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:42:09 UTC to 2016-08-20 19:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:02:09 UTC to 2016-08-20 20:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:22:09 UTC to 2016-08-20 20:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:42:09 UTC to 2016-08-20 20:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:02:09 UTC to 2016-08-20 21:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:22:09 UTC to 2016-08-20 21:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:42:09 UTC to 2016-08-20 21:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:02:09 UTC to 2016-08-20 22:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:22:09 UTC to 2016-08-20 22:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:42:09 UTC to 2016-08-20 22:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:02:09 UTC to 2016-08-20 23:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:22:09 UTC to 2016-08-20 23:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:42:09 UTC to 2016-08-20 23:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:02:09 UTC to 2016-08-21 00:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:22:09 UTC to 2016-08-21 00:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:42:09 UTC to 2016-08-21 00:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:02:09 UTC to 2016-08-21 01:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:22:09 UTC to 2016-08-21 01:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:42:09 UTC to 2016-08-21 01:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:02:09 UTC to 2016-08-21 02:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:22:08 UTC to 2016-08-21 02:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:42:09 UTC to 2016-08-21 02:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:02:09 UTC to 2016-08-21 03:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:22:09 UTC to 2016-08-21 03:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:42:09 UTC to 2016-08-21 03:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:02:08 UTC to 2016-08-21 04:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:22:09 UTC to 2016-08-21 04:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:42:09 UTC to 2016-08-21 04:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:02:08 UTC to 2016-08-21 05:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:22:08 UTC to 2016-08-21 05:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:42:08 UTC to 2016-08-21 05:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:02:08 UTC to 2016-08-21 06:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:22:08 UTC to 2016-08-21 06:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:42:08 UTC to 2016-08-21 06:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:02:08 UTC to 2016-08-21 07:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:22:08 UTC to 2016-08-21 07:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:42:08 UTC to 2016-08-21 07:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:02:09 UTC to 2016-08-21 08:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:22:08 UTC to 2016-08-21 08:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:42:08 UTC to 2016-08-21 08:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:02:08 UTC to 2016-08-21 09:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:22:08 UTC to 2016-08-21 09:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:42:08 UTC to 2016-08-21 09:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:02:08 UTC to 2016-08-21 10:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:22:08 UTC to 2016-08-21 10:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:42:08 UTC to 2016-08-21 10:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:02:08 UTC to 2016-08-21 11:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:22:08 UTC to 2016-08-21 11:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:42:08 UTC to 2016-08-21 11:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:02:08 UTC to 2016-08-21 12:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:22:08 UTC to 2016-08-21 12:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:42:08 UTC to 2016-08-21 12:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:02:08 UTC to 2016-08-21 13:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:22:08 UTC to 2016-08-21 13:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:42:08 UTC to 2016-08-21 13:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:02:08 UTC to 2016-08-21 14:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:22:09 UTC to 2016-08-21 14:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:42:08 UTC to 2016-08-21 14:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:02:08 UTC to 2016-08-21 15:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:22:08 UTC to 2016-08-21 15:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:42:08 UTC to 2016-08-21 15:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:02:08 UTC to 2016-08-21 16:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:22:08 UTC to 2016-08-21 16:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:42:08 UTC to 2016-08-21 16:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:02:08 UTC to 2016-08-21 17:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:22:08 UTC to 2016-08-21 17:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:42:08 UTC to 2016-08-21 17:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:02:08 UTC to 2016-08-21 18:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:22:08 UTC to 2016-08-21 18:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:42:08 UTC to 2016-08-21 18:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:02:08 UTC to 2016-08-21 19:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:22:08 UTC to 2016-08-21 19:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:42:08 UTC to 2016-08-21 19:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:02:08 UTC to 2016-08-21 20:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:22:08 UTC to 2016-08-21 20:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:42:08 UTC to 2016-08-21 20:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:02:08 UTC to 2016-08-21 21:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:22:08 UTC to 2016-08-21 21:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:42:08 UTC to 2016-08-21 21:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:02:08 UTC to 2016-08-21 22:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:22:08 UTC to 2016-08-21 22:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:42:08 UTC to 2016-08-21 22:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:02:08 UTC to 2016-08-21 23:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:22:08 UTC to 2016-08-21 23:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:42:08 UTC to 2016-08-21 23:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:02:08 UTC to 2016-08-22 00:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:22:08 UTC to 2016-08-22 00:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:42:08 UTC to 2016-08-22 00:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:02:08 UTC to 2016-08-22 01:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:22:08 UTC to 2016-08-22 01:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:42:08 UTC to 2016-08-22 01:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:02:08 UTC to 2016-08-22 02:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:22:08 UTC to 2016-08-22 02:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:42:08 UTC to 2016-08-22 02:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:02:08 UTC to 2016-08-22 03:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:22:08 UTC to 2016-08-22 03:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:42:08 UTC to 2016-08-22 03:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:02:08 UTC to 2016-08-22 04:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:22:08 UTC to 2016-08-22 04:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:42:08 UTC to 2016-08-22 04:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:02:08 UTC to 2016-08-22 05:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:22:08 UTC to 2016-08-22 05:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:42:08 UTC to 2016-08-22 05:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:02:08 UTC to 2016-08-22 06:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:22:08 UTC to 2016-08-22 06:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:42:07 UTC to 2016-08-22 06:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:02:08 UTC to 2016-08-22 07:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:22:08 UTC to 2016-08-22 07:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:42:07 UTC to 2016-08-22 07:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:02:07 UTC to 2016-08-22 08:02:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:22:07 UTC to 2016-08-22 08:22:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:42:07 UTC to 2016-08-22 08:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:02:07 UTC to 2016-08-22 09:02:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:22:07 UTC to 2016-08-22 09:22:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:42:07 UTC to 2016-08-22 09:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:07:43 UTC to 2016-08-23 00:08:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:17:43 UTC to 2016-08-23 00:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:37:43 UTC to 2016-08-23 00:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:57:43 UTC to 2016-08-23 00:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:17:43 UTC to 2016-08-23 01:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:37:43 UTC to 2016-08-23 01:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:57:43 UTC to 2016-08-23 01:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:17:43 UTC to 2016-08-23 02:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:37:43 UTC to 2016-08-23 02:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:57:43 UTC to 2016-08-23 02:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:18:34 UTC to 2016-08-23 03:18:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:18:51 UTC to 2016-08-23 03:19:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:05 UTC to 2016-08-23 03:19:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:15 UTC to 2016-08-23 03:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:24 UTC to 2016-08-23 03:19:44 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:37:43 UTC to 2016-08-23 03:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:57:44 UTC to 2016-08-23 03:58:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:17:43 UTC to 2016-08-23 04:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:37:43 UTC to 2016-08-23 04:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:57:43 UTC to 2016-08-23 04:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:17:43 UTC to 2016-08-23 05:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:37:43 UTC to 2016-08-23 05:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:57:43 UTC to 2016-08-23 05:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:17:43 UTC to 2016-08-23 06:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:37:43 UTC to 2016-08-23 06:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:57:43 UTC to 2016-08-23 06:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:17:43 UTC to 2016-08-23 07:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:37:43 UTC to 2016-08-23 07:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:57:43 UTC to 2016-08-23 07:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:17:43 UTC to 2016-08-23 08:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:37:43 UTC to 2016-08-23 08:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:57:43 UTC to 2016-08-23 08:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:17:43 UTC to 2016-08-23 09:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:37:43 UTC to 2016-08-23 09:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:57:43 UTC to 2016-08-23 09:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:17:43 UTC to 2016-08-23 10:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:37:43 UTC to 2016-08-23 10:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:57:43 UTC to 2016-08-23 10:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:17:43 UTC to 2016-08-23 11:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:37:43 UTC to 2016-08-23 11:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:57:43 UTC to 2016-08-23 11:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:17:43 UTC to 2016-08-23 12:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:37:43 UTC to 2016-08-23 12:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:57:43 UTC to 2016-08-23 12:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:17:43 UTC to 2016-08-23 13:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:37:43 UTC to 2016-08-23 13:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:57:43 UTC to 2016-08-23 13:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:17:43 UTC to 2016-08-23 14:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:37:43 UTC to 2016-08-23 14:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:57:43 UTC to 2016-08-23 14:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:17:44 UTC to 2016-08-23 15:18:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:37:43 UTC to 2016-08-23 15:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:57:43 UTC to 2016-08-23 15:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:17:43 UTC to 2016-08-23 16:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:37:42 UTC to 2016-08-23 16:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:57:43 UTC to 2016-08-23 16:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:17:43 UTC to 2016-08-23 17:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:37:43 UTC to 2016-08-23 17:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:57:42 UTC to 2016-08-23 17:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:17:44 UTC to 2016-08-23 18:18:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:37:42 UTC to 2016-08-23 18:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:57:42 UTC to 2016-08-23 18:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:17:42 UTC to 2016-08-23 19:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:37:42 UTC to 2016-08-23 19:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:57:42 UTC to 2016-08-23 19:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:17:42 UTC to 2016-08-23 20:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:37:42 UTC to 2016-08-23 20:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:57:42 UTC to 2016-08-23 20:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:17:42 UTC to 2016-08-23 21:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:37:42 UTC to 2016-08-23 21:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:57:42 UTC to 2016-08-23 21:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:17:42 UTC to 2016-08-23 22:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:37:42 UTC to 2016-08-23 22:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:57:42 UTC to 2016-08-23 22:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:17:42 UTC to 2016-08-23 23:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:37:42 UTC to 2016-08-23 23:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:57:42 UTC to 2016-08-23 23:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:17:42 UTC to 2016-08-24 00:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:37:42 UTC to 2016-08-24 00:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:57:42 UTC to 2016-08-24 00:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:17:42 UTC to 2016-08-24 01:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:37:42 UTC to 2016-08-24 01:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:57:42 UTC to 2016-08-24 01:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:17:42 UTC to 2016-08-24 02:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:37:42 UTC to 2016-08-24 02:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:57:42 UTC to 2016-08-24 02:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:17:42 UTC to 2016-08-24 03:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:37:42 UTC to 2016-08-24 03:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:57:42 UTC to 2016-08-24 03:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:17:42 UTC to 2016-08-24 04:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:37:42 UTC to 2016-08-24 04:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:57:42 UTC to 2016-08-24 04:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:17:42 UTC to 2016-08-24 05:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:37:42 UTC to 2016-08-24 05:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:57:42 UTC to 2016-08-24 05:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:17:42 UTC to 2016-08-24 06:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:37:42 UTC to 2016-08-24 06:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:57:42 UTC to 2016-08-24 06:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:17:42 UTC to 2016-08-24 07:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:37:42 UTC to 2016-08-24 07:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:57:42 UTC to 2016-08-24 07:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:17:42 UTC to 2016-08-24 08:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:37:42 UTC to 2016-08-24 08:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:57:42 UTC to 2016-08-24 08:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:17:42 UTC to 2016-08-24 09:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:37:42 UTC to 2016-08-24 09:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:57:42 UTC to 2016-08-24 09:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:17:42 UTC to 2016-08-24 10:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:37:42 UTC to 2016-08-24 10:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:57:42 UTC to 2016-08-24 10:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:17:42 UTC to 2016-08-24 11:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:37:42 UTC to 2016-08-24 11:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:57:42 UTC to 2016-08-24 11:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:17:42 UTC to 2016-08-24 12:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:37:42 UTC to 2016-08-24 12:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:57:42 UTC to 2016-08-24 12:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:17:42 UTC to 2016-08-24 13:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:37:42 UTC to 2016-08-24 13:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:57:42 UTC to 2016-08-24 13:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:17:42 UTC to 2016-08-24 14:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:37:42 UTC to 2016-08-24 14:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:57:42 UTC to 2016-08-24 14:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:17:42 UTC to 2016-08-24 15:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:37:42 UTC to 2016-08-24 15:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:57:42 UTC to 2016-08-24 15:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:17:42 UTC to 2016-08-24 16:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:37:42 UTC to 2016-08-24 16:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:57:42 UTC to 2016-08-24 16:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:17:42 UTC to 2016-08-24 17:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:37:43 UTC to 2016-08-24 17:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:57:42 UTC to 2016-08-24 17:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:17:42 UTC to 2016-08-24 18:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:37:42 UTC to 2016-08-24 18:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:57:42 UTC to 2016-08-24 18:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:17:42 UTC to 2016-08-24 19:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:37:42 UTC to 2016-08-24 19:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:57:42 UTC to 2016-08-24 19:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:17:42 UTC to 2016-08-24 20:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:37:42 UTC to 2016-08-24 20:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:57:42 UTC to 2016-08-24 20:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:17:41 UTC to 2016-08-24 21:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:37:41 UTC to 2016-08-24 21:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:57:41 UTC to 2016-08-24 21:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:17:41 UTC to 2016-08-24 22:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:37:41 UTC to 2016-08-24 22:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:57:41 UTC to 2016-08-24 22:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:17:41 UTC to 2016-08-24 23:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:37:41 UTC to 2016-08-24 23:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:57:41 UTC to 2016-08-24 23:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:17:41 UTC to 2016-08-25 00:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:37:41 UTC to 2016-08-25 00:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:57:41 UTC to 2016-08-25 00:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:17:41 UTC to 2016-08-25 01:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:37:42 UTC to 2016-08-25 01:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:57:41 UTC to 2016-08-25 01:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:17:41 UTC to 2016-08-25 02:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:37:46 UTC to 2016-08-25 02:38:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:57:41 UTC to 2016-08-25 02:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:17:41 UTC to 2016-08-25 03:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:37:41 UTC to 2016-08-25 03:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:57:41 UTC to 2016-08-25 03:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:17:41 UTC to 2016-08-25 04:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:37:41 UTC to 2016-08-25 04:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:57:41 UTC to 2016-08-25 04:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:17:41 UTC to 2016-08-25 05:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:37:41 UTC to 2016-08-25 05:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:57:43 UTC to 2016-08-25 05:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:17:41 UTC to 2016-08-25 06:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:37:41 UTC to 2016-08-25 06:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:57:41 UTC to 2016-08-25 06:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:17:41 UTC to 2016-08-25 07:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:37:41 UTC to 2016-08-25 07:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:57:41 UTC to 2016-08-25 07:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:17:41 UTC to 2016-08-25 08:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:37:41 UTC to 2016-08-25 08:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:57:41 UTC to 2016-08-25 08:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:17:41 UTC to 2016-08-25 09:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:37:41 UTC to 2016-08-25 09:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:57:41 UTC to 2016-08-25 09:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:17:41 UTC to 2016-08-25 10:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:37:41 UTC to 2016-08-25 10:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:57:41 UTC to 2016-08-25 10:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:17:41 UTC to 2016-08-25 11:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:37:41 UTC to 2016-08-25 11:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:57:41 UTC to 2016-08-25 11:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:17:41 UTC to 2016-08-25 12:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:37:41 UTC to 2016-08-25 12:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:57:41 UTC to 2016-08-25 12:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:17:41 UTC to 2016-08-25 13:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:37:41 UTC to 2016-08-25 13:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:57:41 UTC to 2016-08-25 13:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:17:41 UTC to 2016-08-25 14:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:37:41 UTC to 2016-08-25 14:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:57:42 UTC to 2016-08-25 14:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:17:41 UTC to 2016-08-25 15:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:37:41 UTC to 2016-08-25 15:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:57:41 UTC to 2016-08-25 15:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:17:42 UTC to 2016-08-25 16:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:37:41 UTC to 2016-08-25 16:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:57:41 UTC to 2016-08-25 16:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:17:41 UTC to 2016-08-25 17:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:37:41 UTC to 2016-08-25 17:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:57:41 UTC to 2016-08-25 17:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:17:41 UTC to 2016-08-25 18:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:37:41 UTC to 2016-08-25 18:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:57:41 UTC to 2016-08-25 18:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:17:41 UTC to 2016-08-25 19:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:37:41 UTC to 2016-08-25 19:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:57:41 UTC to 2016-08-25 19:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:17:41 UTC to 2016-08-25 20:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:37:41 UTC to 2016-08-25 20:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:57:41 UTC to 2016-08-25 20:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:17:41 UTC to 2016-08-25 21:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:37:41 UTC to 2016-08-25 21:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:57:40 UTC to 2016-08-25 21:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:17:41 UTC to 2016-08-25 22:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:37:40 UTC to 2016-08-25 22:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:57:40 UTC to 2016-08-25 22:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:17:50 UTC to 2016-08-25 23:18:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:18:02 UTC to 2016-08-25 23:18:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:27:41 UTC to 2016-08-25 23:28:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:37:41 UTC to 2016-08-25 23:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:57:40 UTC to 2016-08-25 23:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:17:41 UTC to 2016-08-26 00:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:37:40 UTC to 2016-08-26 00:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:57:40 UTC to 2016-08-26 00:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:17:41 UTC to 2016-08-26 01:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:37:40 UTC to 2016-08-26 01:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:57:40 UTC to 2016-08-26 01:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:17:40 UTC to 2016-08-26 02:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:37:40 UTC to 2016-08-26 02:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:57:40 UTC to 2016-08-26 02:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:17:40 UTC to 2016-08-26 03:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:37:40 UTC to 2016-08-26 03:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:57:40 UTC to 2016-08-26 03:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:17:40 UTC to 2016-08-26 04:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:37:40 UTC to 2016-08-26 04:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:57:40 UTC to 2016-08-26 04:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:17:40 UTC to 2016-08-26 05:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:37:40 UTC to 2016-08-26 05:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:57:40 UTC to 2016-08-26 05:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:17:40 UTC to 2016-08-26 06:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:37:40 UTC to 2016-08-26 06:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:57:40 UTC to 2016-08-26 06:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:17:40 UTC to 2016-08-26 07:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:37:40 UTC to 2016-08-26 07:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:57:40 UTC to 2016-08-26 07:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:17:40 UTC to 2016-08-26 08:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:37:40 UTC to 2016-08-26 08:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:57:40 UTC to 2016-08-26 08:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:17:40 UTC to 2016-08-26 09:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:37:40 UTC to 2016-08-26 09:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:57:40 UTC to 2016-08-26 09:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:17:40 UTC to 2016-08-26 10:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:37:40 UTC to 2016-08-26 10:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:57:40 UTC to 2016-08-26 10:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:17:40 UTC to 2016-08-26 11:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:37:40 UTC to 2016-08-26 11:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:57:40 UTC to 2016-08-26 11:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:17:40 UTC to 2016-08-26 12:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:37:40 UTC to 2016-08-26 12:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:57:40 UTC to 2016-08-26 12:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:17:40 UTC to 2016-08-26 13:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:37:40 UTC to 2016-08-26 13:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:57:40 UTC to 2016-08-26 13:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:17:40 UTC to 2016-08-26 14:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:37:40 UTC to 2016-08-26 14:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:57:40 UTC to 2016-08-26 14:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:17:40 UTC to 2016-08-26 15:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:37:40 UTC to 2016-08-26 15:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:57:41 UTC to 2016-08-26 15:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:17:40 UTC to 2016-08-26 16:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:37:40 UTC to 2016-08-26 16:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:57:40 UTC to 2016-08-26 16:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:17:40 UTC to 2016-08-26 17:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:37:40 UTC to 2016-08-26 17:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:57:40 UTC to 2016-08-26 17:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:17:40 UTC to 2016-08-26 18:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:37:40 UTC to 2016-08-26 18:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:57:40 UTC to 2016-08-26 18:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:17:40 UTC to 2016-08-26 19:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:37:40 UTC to 2016-08-26 19:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:57:40 UTC to 2016-08-26 19:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:17:40 UTC to 2016-08-26 20:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:37:40 UTC to 2016-08-26 20:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:57:40 UTC to 2016-08-26 20:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:17:40 UTC to 2016-08-26 21:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:37:40 UTC to 2016-08-26 21:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:57:40 UTC to 2016-08-26 21:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:17:40 UTC to 2016-08-26 22:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:37:40 UTC to 2016-08-26 22:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:57:40 UTC to 2016-08-26 22:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:17:40 UTC to 2016-08-26 23:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:37:40 UTC to 2016-08-26 23:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:57:40 UTC to 2016-08-26 23:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:17:40 UTC to 2016-08-27 00:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:37:40 UTC to 2016-08-27 00:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:57:40 UTC to 2016-08-27 00:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:17:40 UTC to 2016-08-27 01:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:37:39 UTC to 2016-08-27 01:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:57:40 UTC to 2016-08-27 01:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:17:39 UTC to 2016-08-27 02:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:37:39 UTC to 2016-08-27 02:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:57:39 UTC to 2016-08-27 02:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:17:39 UTC to 2016-08-27 03:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:37:39 UTC to 2016-08-27 03:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:57:39 UTC to 2016-08-27 03:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:17:39 UTC to 2016-08-27 04:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:37:39 UTC to 2016-08-27 04:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:57:39 UTC to 2016-08-27 04:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:17:39 UTC to 2016-08-27 05:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:37:39 UTC to 2016-08-27 05:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:57:39 UTC to 2016-08-27 05:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:17:39 UTC to 2016-08-27 06:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:37:39 UTC to 2016-08-27 06:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:57:39 UTC to 2016-08-27 06:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:17:39 UTC to 2016-08-27 07:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:37:39 UTC to 2016-08-27 07:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:57:39 UTC to 2016-08-27 07:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:17:39 UTC to 2016-08-27 08:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:37:39 UTC to 2016-08-27 08:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:57:39 UTC to 2016-08-27 08:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:17:39 UTC to 2016-08-27 09:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:37:39 UTC to 2016-08-27 09:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:57:39 UTC to 2016-08-27 09:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:17:39 UTC to 2016-08-27 10:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:37:39 UTC to 2016-08-27 10:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:57:39 UTC to 2016-08-27 10:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:17:39 UTC to 2016-08-27 11:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:37:39 UTC to 2016-08-27 11:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:57:39 UTC to 2016-08-27 11:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:17:39 UTC to 2016-08-27 12:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:37:39 UTC to 2016-08-27 12:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:57:39 UTC to 2016-08-27 12:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:17:39 UTC to 2016-08-27 13:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:37:39 UTC to 2016-08-27 13:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:57:39 UTC to 2016-08-27 13:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:17:39 UTC to 2016-08-27 14:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:37:39 UTC to 2016-08-27 14:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:57:39 UTC to 2016-08-27 14:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:17:39 UTC to 2016-08-27 15:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:37:39 UTC to 2016-08-27 15:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:57:39 UTC to 2016-08-27 15:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:17:39 UTC to 2016-08-27 16:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:37:39 UTC to 2016-08-27 16:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:57:39 UTC to 2016-08-27 16:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:17:39 UTC to 2016-08-27 17:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:37:39 UTC to 2016-08-27 17:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:57:39 UTC to 2016-08-27 17:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:17:39 UTC to 2016-08-27 18:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:37:39 UTC to 2016-08-27 18:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:57:39 UTC to 2016-08-27 18:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:17:39 UTC to 2016-08-27 19:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:37:39 UTC to 2016-08-27 19:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:57:39 UTC to 2016-08-27 19:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:17:39 UTC to 2016-08-27 20:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:37:39 UTC to 2016-08-27 20:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:57:39 UTC to 2016-08-27 20:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:17:39 UTC to 2016-08-27 21:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:37:39 UTC to 2016-08-27 21:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:57:39 UTC to 2016-08-27 21:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:17:39 UTC to 2016-08-27 22:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:37:39 UTC to 2016-08-27 22:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:57:39 UTC to 2016-08-27 22:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:17:39 UTC to 2016-08-27 23:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:37:39 UTC to 2016-08-27 23:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:57:39 UTC to 2016-08-27 23:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:17:39 UTC to 2016-08-28 00:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:37:39 UTC to 2016-08-28 00:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:57:39 UTC to 2016-08-28 00:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:17:39 UTC to 2016-08-28 01:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:37:39 UTC to 2016-08-28 01:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:57:39 UTC to 2016-08-28 01:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:17:39 UTC to 2016-08-28 02:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:37:39 UTC to 2016-08-28 02:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:57:39 UTC to 2016-08-28 02:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:17:39 UTC to 2016-08-28 03:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:37:39 UTC to 2016-08-28 03:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:57:39 UTC to 2016-08-28 03:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:17:39 UTC to 2016-08-28 04:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:37:39 UTC to 2016-08-28 04:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:57:39 UTC to 2016-08-28 04:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:12:03 UTC to 2016-08-29 01:12:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:22:03 UTC to 2016-08-29 01:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:42:03 UTC to 2016-08-29 01:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:02:03 UTC to 2016-08-29 02:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:22:03 UTC to 2016-08-29 02:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:42:03 UTC to 2016-08-29 02:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:02:03 UTC to 2016-08-29 03:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:22:03 UTC to 2016-08-29 03:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:42:03 UTC to 2016-08-29 03:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:02:03 UTC to 2016-08-29 04:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:22:03 UTC to 2016-08-29 04:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:42:03 UTC to 2016-08-29 04:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:02:03 UTC to 2016-08-29 05:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:22:03 UTC to 2016-08-29 05:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:42:03 UTC to 2016-08-29 05:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:02:03 UTC to 2016-08-29 06:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:22:03 UTC to 2016-08-29 06:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:42:03 UTC to 2016-08-29 06:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:02:03 UTC to 2016-08-29 07:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:22:03 UTC to 2016-08-29 07:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:42:03 UTC to 2016-08-29 07:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:02:03 UTC to 2016-08-29 08:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:22:03 UTC to 2016-08-29 08:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:42:03 UTC to 2016-08-29 08:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:02:03 UTC to 2016-08-29 09:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:22:03 UTC to 2016-08-29 09:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:42:03 UTC to 2016-08-29 09:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:02:03 UTC to 2016-08-29 10:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:22:03 UTC to 2016-08-29 10:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:42:03 UTC to 2016-08-29 10:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:02:03 UTC to 2016-08-29 11:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:22:03 UTC to 2016-08-29 11:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:42:03 UTC to 2016-08-29 11:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:02:03 UTC to 2016-08-29 12:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:22:03 UTC to 2016-08-29 12:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:42:03 UTC to 2016-08-29 12:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:02:03 UTC to 2016-08-29 13:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:22:03 UTC to 2016-08-29 13:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:42:03 UTC to 2016-08-29 13:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:02:03 UTC to 2016-08-29 14:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:22:03 UTC to 2016-08-29 14:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:42:03 UTC to 2016-08-29 14:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:02:03 UTC to 2016-08-29 15:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:22:03 UTC to 2016-08-29 15:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:42:03 UTC to 2016-08-29 15:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:02:03 UTC to 2016-08-29 16:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:22:03 UTC to 2016-08-29 16:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:42:03 UTC to 2016-08-29 16:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:02:03 UTC to 2016-08-29 17:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:22:03 UTC to 2016-08-29 17:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:42:03 UTC to 2016-08-29 17:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:02:03 UTC to 2016-08-29 18:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:22:03 UTC to 2016-08-29 18:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:42:03 UTC to 2016-08-29 18:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:02:03 UTC to 2016-08-29 19:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:22:03 UTC to 2016-08-29 19:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:42:03 UTC to 2016-08-29 19:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:02:03 UTC to 2016-08-29 20:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:22:03 UTC to 2016-08-29 20:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:42:03 UTC to 2016-08-29 20:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:02:03 UTC to 2016-08-29 21:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:22:02 UTC to 2016-08-29 21:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:42:03 UTC to 2016-08-29 21:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:02:03 UTC to 2016-08-29 22:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:22:02 UTC to 2016-08-29 22:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:42:02 UTC to 2016-08-29 22:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:02:02 UTC to 2016-08-29 23:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:22:02 UTC to 2016-08-29 23:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:42:03 UTC to 2016-08-29 23:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:02:02 UTC to 2016-08-30 00:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:22:02 UTC to 2016-08-30 00:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:42:03 UTC to 2016-08-30 00:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:02:02 UTC to 2016-08-30 01:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:22:02 UTC to 2016-08-30 01:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:42:02 UTC to 2016-08-30 01:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:02:02 UTC to 2016-08-30 02:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:22:02 UTC to 2016-08-30 02:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:42:02 UTC to 2016-08-30 02:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:02:02 UTC to 2016-08-30 03:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:22:02 UTC to 2016-08-30 03:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:42:02 UTC to 2016-08-30 03:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:02:02 UTC to 2016-08-30 04:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:22:02 UTC to 2016-08-30 04:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:42:02 UTC to 2016-08-30 04:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:02:02 UTC to 2016-08-30 05:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:22:02 UTC to 2016-08-30 05:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:42:02 UTC to 2016-08-30 05:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:02:02 UTC to 2016-08-30 06:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:22:02 UTC to 2016-08-30 06:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:42:02 UTC to 2016-08-30 06:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:02:02 UTC to 2016-08-30 07:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:22:02 UTC to 2016-08-30 07:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:42:02 UTC to 2016-08-30 07:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:02:02 UTC to 2016-08-30 08:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:22:02 UTC to 2016-08-30 08:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:42:02 UTC to 2016-08-30 08:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:02:02 UTC to 2016-08-30 09:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:22:02 UTC to 2016-08-30 09:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:42:02 UTC to 2016-08-30 09:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:02:02 UTC to 2016-08-30 10:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:22:02 UTC to 2016-08-30 10:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:42:02 UTC to 2016-08-30 10:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:02:02 UTC to 2016-08-30 11:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:22:02 UTC to 2016-08-30 11:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:42:02 UTC to 2016-08-30 11:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:02:02 UTC to 2016-08-30 12:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:22:02 UTC to 2016-08-30 12:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:42:02 UTC to 2016-08-30 12:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:02:02 UTC to 2016-08-30 13:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:22:02 UTC to 2016-08-30 13:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:42:02 UTC to 2016-08-30 13:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 14:02:02 UTC to 2016-08-30 14:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 14:22:02 UTC to 2016-08-30 14:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:01:16 UTC to 2016-08-31 00:01:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:21:16 UTC to 2016-08-31 00:21:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:41:15 UTC to 2016-08-31 00:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:01:16 UTC to 2016-08-31 01:01:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:21:15 UTC to 2016-08-31 01:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:41:16 UTC to 2016-08-31 01:41:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:01:15 UTC to 2016-08-31 02:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:21:15 UTC to 2016-08-31 02:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:41:15 UTC to 2016-08-31 02:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:01:15 UTC to 2016-08-31 03:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:21:15 UTC to 2016-08-31 03:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:41:15 UTC to 2016-08-31 03:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:01:15 UTC to 2016-08-31 04:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:21:15 UTC to 2016-08-31 04:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:41:15 UTC to 2016-08-31 04:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:01:15 UTC to 2016-08-31 05:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:21:15 UTC to 2016-08-31 05:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:41:15 UTC to 2016-08-31 05:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:01:15 UTC to 2016-08-31 06:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:21:15 UTC to 2016-08-31 06:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:41:15 UTC to 2016-08-31 06:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:01:15 UTC to 2016-08-31 07:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:21:15 UTC to 2016-08-31 07:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:41:15 UTC to 2016-08-31 07:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:01:15 UTC to 2016-08-31 08:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:21:15 UTC to 2016-08-31 08:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:41:15 UTC to 2016-08-31 08:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:01:15 UTC to 2016-08-31 09:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:21:15 UTC to 2016-08-31 09:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:41:15 UTC to 2016-08-31 09:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:01:15 UTC to 2016-08-31 10:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:21:15 UTC to 2016-08-31 10:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:41:15 UTC to 2016-08-31 10:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:01:15 UTC to 2016-08-31 11:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:21:15 UTC to 2016-08-31 11:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:41:15 UTC to 2016-08-31 11:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:01:15 UTC to 2016-08-31 12:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:21:15 UTC to 2016-08-31 12:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:41:15 UTC to 2016-08-31 12:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:01:15 UTC to 2016-08-31 13:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:21:15 UTC to 2016-08-31 13:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:41:15 UTC to 2016-08-31 13:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:01:15 UTC to 2016-08-31 14:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:21:15 UTC to 2016-08-31 14:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:41:15 UTC to 2016-08-31 14:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:01:15 UTC to 2016-08-31 15:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:21:15 UTC to 2016-08-31 15:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:41:15 UTC to 2016-08-31 15:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:01:15 UTC to 2016-08-31 16:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:21:15 UTC to 2016-08-31 16:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:41:15 UTC to 2016-08-31 16:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:01:15 UTC to 2016-08-31 17:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:21:15 UTC to 2016-08-31 17:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:41:15 UTC to 2016-08-31 17:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:01:15 UTC to 2016-08-31 18:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:21:15 UTC to 2016-08-31 18:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:41:15 UTC to 2016-08-31 18:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:01:15 UTC to 2016-08-31 19:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:21:15 UTC to 2016-08-31 19:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:41:15 UTC to 2016-08-31 19:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:01:15 UTC to 2016-08-31 20:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:21:15 UTC to 2016-08-31 20:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:41:15 UTC to 2016-08-31 20:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:01:15 UTC to 2016-08-31 21:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:21:15 UTC to 2016-08-31 21:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:41:15 UTC to 2016-08-31 21:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:01:15 UTC to 2016-08-31 22:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:21:15 UTC to 2016-08-31 22:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:41:15 UTC to 2016-08-31 22:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:01:15 UTC to 2016-08-31 23:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:21:15 UTC to 2016-08-31 23:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:41:15 UTC to 2016-08-31 23:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:01:15 UTC to 2016-09-01 00:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:21:15 UTC to 2016-09-01 00:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:41:15 UTC to 2016-09-01 00:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:01:15 UTC to 2016-09-01 01:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:21:15 UTC to 2016-09-01 01:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:41:15 UTC to 2016-09-01 01:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:01:15 UTC to 2016-09-01 02:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:21:15 UTC to 2016-09-01 02:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:41:15 UTC to 2016-09-01 02:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:01:14 UTC to 2016-09-01 03:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:21:14 UTC to 2016-09-01 03:21:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:41:15 UTC to 2016-09-01 03:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:01:14 UTC to 2016-09-01 04:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:21:15 UTC to 2016-09-01 04:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:41:15 UTC to 2016-09-01 04:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 05:01:14 UTC to 2016-09-01 05:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 05:21:14 UTC to 2016-09-01 05:21:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-08-02 14:32:57 UTC to 2016-08-02 14:33:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 14:42:57 UTC to 2016-08-02 14:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 14:52:57 UTC to 2016-08-02 14:53:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:02:57 UTC to 2016-08-02 15:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:22:57 UTC to 2016-08-02 15:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:42:57 UTC to 2016-08-02 15:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:02:57 UTC to 2016-08-02 16:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:22:57 UTC to 2016-08-02 16:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:42:57 UTC to 2016-08-02 16:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:02:57 UTC to 2016-08-02 17:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:22:57 UTC to 2016-08-02 17:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:42:57 UTC to 2016-08-02 17:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:02:57 UTC to 2016-08-02 18:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:22:57 UTC to 2016-08-02 18:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:42:57 UTC to 2016-08-02 18:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:02:57 UTC to 2016-08-02 19:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:22:57 UTC to 2016-08-02 19:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:42:57 UTC to 2016-08-02 19:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:02:57 UTC to 2016-08-02 20:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:22:57 UTC to 2016-08-02 20:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:42:57 UTC to 2016-08-02 20:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:02:57 UTC to 2016-08-02 21:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:22:57 UTC to 2016-08-02 21:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:42:56 UTC to 2016-08-02 21:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:02:56 UTC to 2016-08-02 22:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:22:56 UTC to 2016-08-02 22:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:42:56 UTC to 2016-08-02 22:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:02:57 UTC to 2016-08-02 23:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:22:56 UTC to 2016-08-02 23:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:42:56 UTC to 2016-08-02 23:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:02:56 UTC to 2016-08-03 00:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:22:56 UTC to 2016-08-03 00:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:42:56 UTC to 2016-08-03 00:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:02:56 UTC to 2016-08-03 01:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:22:56 UTC to 2016-08-03 01:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:42:56 UTC to 2016-08-03 01:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:02:56 UTC to 2016-08-03 02:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:22:56 UTC to 2016-08-03 02:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:42:56 UTC to 2016-08-03 02:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:02:56 UTC to 2016-08-03 03:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:22:56 UTC to 2016-08-03 03:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:42:56 UTC to 2016-08-03 03:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:02:56 UTC to 2016-08-03 04:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:22:56 UTC to 2016-08-03 04:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:42:56 UTC to 2016-08-03 04:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:02:56 UTC to 2016-08-03 05:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:22:56 UTC to 2016-08-03 05:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:42:56 UTC to 2016-08-03 05:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:02:56 UTC to 2016-08-03 06:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:22:56 UTC to 2016-08-03 06:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:42:56 UTC to 2016-08-03 06:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:02:56 UTC to 2016-08-03 07:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:22:56 UTC to 2016-08-03 07:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:42:56 UTC to 2016-08-03 07:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:02:56 UTC to 2016-08-03 08:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:22:56 UTC to 2016-08-03 08:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:42:56 UTC to 2016-08-03 08:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:02:56 UTC to 2016-08-03 09:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:22:56 UTC to 2016-08-03 09:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:42:56 UTC to 2016-08-03 09:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:02:56 UTC to 2016-08-03 10:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:22:56 UTC to 2016-08-03 10:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:42:56 UTC to 2016-08-03 10:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:02:56 UTC to 2016-08-03 11:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:22:56 UTC to 2016-08-03 11:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:42:56 UTC to 2016-08-03 11:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:02:56 UTC to 2016-08-03 12:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:22:56 UTC to 2016-08-03 12:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:42:56 UTC to 2016-08-03 12:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:02:56 UTC to 2016-08-03 13:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:22:56 UTC to 2016-08-03 13:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:42:56 UTC to 2016-08-03 13:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:02:56 UTC to 2016-08-03 14:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:22:56 UTC to 2016-08-03 14:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:42:56 UTC to 2016-08-03 14:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:02:56 UTC to 2016-08-03 15:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:22:56 UTC to 2016-08-03 15:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:42:56 UTC to 2016-08-03 15:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:02:56 UTC to 2016-08-03 16:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:22:56 UTC to 2016-08-03 16:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:42:56 UTC to 2016-08-03 16:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:02:56 UTC to 2016-08-03 17:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:22:56 UTC to 2016-08-03 17:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:42:56 UTC to 2016-08-03 17:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:02:56 UTC to 2016-08-03 18:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:22:56 UTC to 2016-08-03 18:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:42:56 UTC to 2016-08-03 18:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:02:56 UTC to 2016-08-03 19:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:22:56 UTC to 2016-08-03 19:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:42:56 UTC to 2016-08-03 19:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:02:56 UTC to 2016-08-03 20:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:22:56 UTC to 2016-08-03 20:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:42:56 UTC to 2016-08-03 20:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:02:56 UTC to 2016-08-03 21:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:22:56 UTC to 2016-08-03 21:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:42:56 UTC to 2016-08-03 21:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:02:56 UTC to 2016-08-03 22:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:22:56 UTC to 2016-08-03 22:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:42:56 UTC to 2016-08-03 22:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:02:55 UTC to 2016-08-03 23:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:22:55 UTC to 2016-08-03 23:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:42:55 UTC to 2016-08-03 23:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:02:56 UTC to 2016-08-04 00:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:22:55 UTC to 2016-08-04 00:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:42:56 UTC to 2016-08-04 00:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:02:55 UTC to 2016-08-04 01:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:22:55 UTC to 2016-08-04 01:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:42:55 UTC to 2016-08-04 01:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:02:55 UTC to 2016-08-04 02:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:22:56 UTC to 2016-08-04 02:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:42:55 UTC to 2016-08-04 02:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:02:55 UTC to 2016-08-04 03:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:22:55 UTC to 2016-08-04 03:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:42:55 UTC to 2016-08-04 03:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:02:55 UTC to 2016-08-04 04:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:22:55 UTC to 2016-08-04 04:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:42:55 UTC to 2016-08-04 04:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:02:55 UTC to 2016-08-04 05:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:22:55 UTC to 2016-08-04 05:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:42:55 UTC to 2016-08-04 05:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:02:55 UTC to 2016-08-04 06:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:22:55 UTC to 2016-08-04 06:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:42:55 UTC to 2016-08-04 06:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:02:55 UTC to 2016-08-04 07:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:22:55 UTC to 2016-08-04 07:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:42:55 UTC to 2016-08-04 07:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:02:55 UTC to 2016-08-04 08:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:22:55 UTC to 2016-08-04 08:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:42:55 UTC to 2016-08-04 08:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:02:55 UTC to 2016-08-04 09:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:22:55 UTC to 2016-08-04 09:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:42:55 UTC to 2016-08-04 09:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:02:55 UTC to 2016-08-04 10:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:22:55 UTC to 2016-08-04 10:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:42:55 UTC to 2016-08-04 10:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:02:55 UTC to 2016-08-04 11:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:22:55 UTC to 2016-08-04 11:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:42:55 UTC to 2016-08-04 11:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:02:55 UTC to 2016-08-04 12:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:22:55 UTC to 2016-08-04 12:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:42:55 UTC to 2016-08-04 12:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:02:55 UTC to 2016-08-04 13:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:22:55 UTC to 2016-08-04 13:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:42:55 UTC to 2016-08-04 13:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 14:02:55 UTC to 2016-08-04 14:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:02:55 UTC to 2016-08-04 15:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:22:55 UTC to 2016-08-04 15:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:42:55 UTC to 2016-08-04 15:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:02:55 UTC to 2016-08-04 16:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:22:55 UTC to 2016-08-04 16:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:42:55 UTC to 2016-08-04 16:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:02:55 UTC to 2016-08-04 17:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:22:55 UTC to 2016-08-04 17:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:42:55 UTC to 2016-08-04 17:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:02:55 UTC to 2016-08-04 18:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:22:55 UTC to 2016-08-04 18:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:42:55 UTC to 2016-08-04 18:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:02:55 UTC to 2016-08-04 19:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:22:55 UTC to 2016-08-04 19:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:42:55 UTC to 2016-08-04 19:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:02:55 UTC to 2016-08-04 20:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:22:55 UTC to 2016-08-04 20:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:42:55 UTC to 2016-08-04 20:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:02:56 UTC to 2016-08-04 21:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:22:55 UTC to 2016-08-04 21:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:42:55 UTC to 2016-08-04 21:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:02:55 UTC to 2016-08-04 22:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:22:55 UTC to 2016-08-04 22:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:42:55 UTC to 2016-08-04 22:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:02:57 UTC to 2016-08-04 23:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:22:56 UTC to 2016-08-04 23:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:42:55 UTC to 2016-08-04 23:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:02:55 UTC to 2016-08-05 00:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:22:55 UTC to 2016-08-05 00:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:42:55 UTC to 2016-08-05 00:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:02:55 UTC to 2016-08-05 01:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:22:55 UTC to 2016-08-05 01:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:42:55 UTC to 2016-08-05 01:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:02:55 UTC to 2016-08-05 02:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:22:55 UTC to 2016-08-05 02:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:42:55 UTC to 2016-08-05 02:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:02:55 UTC to 2016-08-05 03:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:22:54 UTC to 2016-08-05 03:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:42:54 UTC to 2016-08-05 03:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:02:54 UTC to 2016-08-05 04:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:22:54 UTC to 2016-08-05 04:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:42:54 UTC to 2016-08-05 04:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:02:54 UTC to 2016-08-05 05:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:22:54 UTC to 2016-08-05 05:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:42:54 UTC to 2016-08-05 05:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:02:54 UTC to 2016-08-05 06:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:22:54 UTC to 2016-08-05 06:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:42:54 UTC to 2016-08-05 06:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:02:54 UTC to 2016-08-05 07:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:22:54 UTC to 2016-08-05 07:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:42:54 UTC to 2016-08-05 07:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:02:54 UTC to 2016-08-05 08:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:22:54 UTC to 2016-08-05 08:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:42:54 UTC to 2016-08-05 08:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 09:02:54 UTC to 2016-08-05 09:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 09:22:54 UTC to 2016-08-05 09:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:05:28 UTC to 2016-08-05 23:05:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:15:30 UTC to 2016-08-05 23:15:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:35:28 UTC to 2016-08-05 23:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:55:28 UTC to 2016-08-05 23:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:15:28 UTC to 2016-08-06 00:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:35:28 UTC to 2016-08-06 00:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:55:28 UTC to 2016-08-06 00:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:15:28 UTC to 2016-08-06 01:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:35:28 UTC to 2016-08-06 01:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:55:28 UTC to 2016-08-06 01:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:15:28 UTC to 2016-08-06 02:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:35:28 UTC to 2016-08-06 02:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:55:28 UTC to 2016-08-06 02:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:15:28 UTC to 2016-08-06 03:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:35:28 UTC to 2016-08-06 03:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:55:28 UTC to 2016-08-06 03:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:15:28 UTC to 2016-08-06 04:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:35:28 UTC to 2016-08-06 04:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:55:28 UTC to 2016-08-06 04:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:15:28 UTC to 2016-08-06 05:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:35:28 UTC to 2016-08-06 05:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:55:28 UTC to 2016-08-06 05:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:15:28 UTC to 2016-08-06 06:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:35:28 UTC to 2016-08-06 06:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:55:28 UTC to 2016-08-06 06:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:15:28 UTC to 2016-08-06 07:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:35:28 UTC to 2016-08-06 07:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:55:28 UTC to 2016-08-06 07:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:15:28 UTC to 2016-08-06 08:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:35:27 UTC to 2016-08-06 08:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:55:28 UTC to 2016-08-06 08:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:15:28 UTC to 2016-08-06 09:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:35:27 UTC to 2016-08-06 09:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:55:27 UTC to 2016-08-06 09:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:15:27 UTC to 2016-08-06 10:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:35:27 UTC to 2016-08-06 10:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:55:27 UTC to 2016-08-06 10:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:15:28 UTC to 2016-08-06 11:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:35:27 UTC to 2016-08-06 11:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:55:27 UTC to 2016-08-06 11:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:15:27 UTC to 2016-08-06 12:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:35:27 UTC to 2016-08-06 12:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:55:27 UTC to 2016-08-06 12:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:15:27 UTC to 2016-08-06 13:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:35:27 UTC to 2016-08-06 13:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:55:27 UTC to 2016-08-06 13:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:15:27 UTC to 2016-08-06 14:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:35:27 UTC to 2016-08-06 14:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:55:27 UTC to 2016-08-06 14:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:15:27 UTC to 2016-08-06 15:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:35:27 UTC to 2016-08-06 15:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:55:27 UTC to 2016-08-06 15:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:15:27 UTC to 2016-08-06 16:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:35:27 UTC to 2016-08-06 16:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:55:27 UTC to 2016-08-06 16:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:15:27 UTC to 2016-08-06 17:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:35:27 UTC to 2016-08-06 17:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:55:27 UTC to 2016-08-06 17:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:15:27 UTC to 2016-08-06 18:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:35:27 UTC to 2016-08-06 18:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:55:27 UTC to 2016-08-06 18:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:15:27 UTC to 2016-08-06 19:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:35:27 UTC to 2016-08-06 19:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:55:27 UTC to 2016-08-06 19:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:15:27 UTC to 2016-08-06 20:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:35:27 UTC to 2016-08-06 20:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:55:27 UTC to 2016-08-06 20:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:15:27 UTC to 2016-08-06 21:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:35:27 UTC to 2016-08-06 21:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:55:27 UTC to 2016-08-06 21:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:15:27 UTC to 2016-08-06 22:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:35:27 UTC to 2016-08-06 22:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:55:27 UTC to 2016-08-06 22:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:15:27 UTC to 2016-08-06 23:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:35:27 UTC to 2016-08-06 23:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:55:27 UTC to 2016-08-06 23:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:15:27 UTC to 2016-08-07 00:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:35:27 UTC to 2016-08-07 00:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:55:27 UTC to 2016-08-07 00:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:15:27 UTC to 2016-08-07 01:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:35:27 UTC to 2016-08-07 01:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:55:27 UTC to 2016-08-07 01:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:15:27 UTC to 2016-08-07 02:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:35:27 UTC to 2016-08-07 02:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:55:27 UTC to 2016-08-07 02:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:15:27 UTC to 2016-08-07 03:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:35:27 UTC to 2016-08-07 03:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:55:27 UTC to 2016-08-07 03:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:15:27 UTC to 2016-08-07 04:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:35:27 UTC to 2016-08-07 04:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:55:27 UTC to 2016-08-07 04:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:15:27 UTC to 2016-08-07 05:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:35:27 UTC to 2016-08-07 05:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:55:27 UTC to 2016-08-07 05:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:15:27 UTC to 2016-08-07 06:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:35:27 UTC to 2016-08-07 06:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:55:27 UTC to 2016-08-07 06:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:15:27 UTC to 2016-08-07 07:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:35:27 UTC to 2016-08-07 07:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:55:27 UTC to 2016-08-07 07:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:15:27 UTC to 2016-08-07 08:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:35:27 UTC to 2016-08-07 08:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:55:27 UTC to 2016-08-07 08:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:15:27 UTC to 2016-08-07 09:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:35:27 UTC to 2016-08-07 09:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:55:27 UTC to 2016-08-07 09:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:15:27 UTC to 2016-08-07 10:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:35:27 UTC to 2016-08-07 10:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:55:27 UTC to 2016-08-07 10:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:15:27 UTC to 2016-08-07 11:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:35:27 UTC to 2016-08-07 11:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:55:27 UTC to 2016-08-07 11:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:15:27 UTC to 2016-08-07 12:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:35:27 UTC to 2016-08-07 12:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:55:27 UTC to 2016-08-07 12:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:15:27 UTC to 2016-08-07 13:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:35:26 UTC to 2016-08-07 13:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:55:26 UTC to 2016-08-07 13:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:15:26 UTC to 2016-08-07 14:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:35:26 UTC to 2016-08-07 14:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:55:26 UTC to 2016-08-07 14:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:15:26 UTC to 2016-08-07 15:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:35:27 UTC to 2016-08-07 15:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:55:26 UTC to 2016-08-07 15:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:15:26 UTC to 2016-08-07 16:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:35:26 UTC to 2016-08-07 16:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:55:26 UTC to 2016-08-07 16:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:15:26 UTC to 2016-08-07 17:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:35:26 UTC to 2016-08-07 17:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:55:26 UTC to 2016-08-07 17:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:15:26 UTC to 2016-08-07 18:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:35:26 UTC to 2016-08-07 18:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:55:26 UTC to 2016-08-07 18:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:15:26 UTC to 2016-08-07 19:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:35:26 UTC to 2016-08-07 19:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:55:26 UTC to 2016-08-07 19:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:15:26 UTC to 2016-08-07 20:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:35:26 UTC to 2016-08-07 20:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:55:26 UTC to 2016-08-07 20:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:15:26 UTC to 2016-08-07 21:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:35:26 UTC to 2016-08-07 21:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:55:26 UTC to 2016-08-07 21:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:15:26 UTC to 2016-08-07 22:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:35:26 UTC to 2016-08-07 22:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:55:26 UTC to 2016-08-07 22:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:15:26 UTC to 2016-08-07 23:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:35:26 UTC to 2016-08-07 23:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:55:26 UTC to 2016-08-07 23:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:15:26 UTC to 2016-08-08 00:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:35:26 UTC to 2016-08-08 00:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:55:26 UTC to 2016-08-08 00:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:15:26 UTC to 2016-08-08 01:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:35:26 UTC to 2016-08-08 01:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:55:26 UTC to 2016-08-08 01:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:15:26 UTC to 2016-08-08 02:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:35:26 UTC to 2016-08-08 02:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:55:26 UTC to 2016-08-08 02:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:15:26 UTC to 2016-08-08 03:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:35:26 UTC to 2016-08-08 03:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:55:26 UTC to 2016-08-08 03:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:15:26 UTC to 2016-08-08 04:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:35:26 UTC to 2016-08-08 04:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:55:26 UTC to 2016-08-08 04:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:15:26 UTC to 2016-08-08 05:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:35:26 UTC to 2016-08-08 05:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:55:26 UTC to 2016-08-08 05:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:15:26 UTC to 2016-08-08 06:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:35:26 UTC to 2016-08-08 06:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:55:26 UTC to 2016-08-08 06:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 07:15:26 UTC to 2016-08-08 07:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 07:35:26 UTC to 2016-08-08 07:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:19:04 UTC to 2016-08-09 20:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:39:04 UTC to 2016-08-09 20:39:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:59:04 UTC to 2016-08-09 20:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:19:04 UTC to 2016-08-09 21:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:39:04 UTC to 2016-08-09 21:39:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:59:04 UTC to 2016-08-09 21:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:19:03 UTC to 2016-08-09 22:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:39:03 UTC to 2016-08-09 22:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:59:03 UTC to 2016-08-09 22:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:19:03 UTC to 2016-08-09 23:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:39:03 UTC to 2016-08-09 23:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:59:04 UTC to 2016-08-09 23:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:19:03 UTC to 2016-08-10 00:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:39:03 UTC to 2016-08-10 00:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:59:03 UTC to 2016-08-10 00:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:19:04 UTC to 2016-08-10 01:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:39:03 UTC to 2016-08-10 01:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:59:03 UTC to 2016-08-10 01:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:19:03 UTC to 2016-08-10 02:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:39:03 UTC to 2016-08-10 02:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:59:03 UTC to 2016-08-10 02:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:19:03 UTC to 2016-08-10 03:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:39:03 UTC to 2016-08-10 03:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:59:03 UTC to 2016-08-10 03:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:19:03 UTC to 2016-08-10 04:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:39:03 UTC to 2016-08-10 04:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:59:03 UTC to 2016-08-10 04:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:19:03 UTC to 2016-08-10 05:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:39:03 UTC to 2016-08-10 05:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:59:03 UTC to 2016-08-10 05:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:19:03 UTC to 2016-08-10 06:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:39:03 UTC to 2016-08-10 06:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:59:03 UTC to 2016-08-10 06:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:19:03 UTC to 2016-08-10 07:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:39:03 UTC to 2016-08-10 07:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:59:03 UTC to 2016-08-10 07:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:19:03 UTC to 2016-08-10 08:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:39:03 UTC to 2016-08-10 08:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:59:03 UTC to 2016-08-10 08:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:19:03 UTC to 2016-08-10 09:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:39:03 UTC to 2016-08-10 09:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:59:03 UTC to 2016-08-10 09:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:19:03 UTC to 2016-08-10 10:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:39:03 UTC to 2016-08-10 10:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:59:03 UTC to 2016-08-10 10:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:19:03 UTC to 2016-08-10 11:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:39:03 UTC to 2016-08-10 11:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:59:03 UTC to 2016-08-10 11:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:19:03 UTC to 2016-08-10 12:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:39:03 UTC to 2016-08-10 12:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:59:03 UTC to 2016-08-10 12:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:19:03 UTC to 2016-08-10 13:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:39:03 UTC to 2016-08-10 13:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:59:03 UTC to 2016-08-10 13:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:19:03 UTC to 2016-08-10 14:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:39:03 UTC to 2016-08-10 14:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:59:03 UTC to 2016-08-10 14:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:19:03 UTC to 2016-08-10 15:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:39:03 UTC to 2016-08-10 15:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:59:03 UTC to 2016-08-10 15:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:19:03 UTC to 2016-08-10 16:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:39:03 UTC to 2016-08-10 16:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:59:03 UTC to 2016-08-10 16:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:19:03 UTC to 2016-08-10 17:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:39:03 UTC to 2016-08-10 17:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:59:03 UTC to 2016-08-10 17:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:19:03 UTC to 2016-08-10 18:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:39:03 UTC to 2016-08-10 18:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:59:03 UTC to 2016-08-10 18:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:19:03 UTC to 2016-08-10 19:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:39:03 UTC to 2016-08-10 19:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:59:03 UTC to 2016-08-10 19:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:19:03 UTC to 2016-08-10 20:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:39:03 UTC to 2016-08-10 20:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:59:03 UTC to 2016-08-10 20:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:19:03 UTC to 2016-08-10 21:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:39:03 UTC to 2016-08-10 21:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:59:03 UTC to 2016-08-10 21:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:19:03 UTC to 2016-08-10 22:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:39:03 UTC to 2016-08-10 22:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:59:03 UTC to 2016-08-10 22:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:19:03 UTC to 2016-08-10 23:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:39:03 UTC to 2016-08-10 23:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:59:03 UTC to 2016-08-10 23:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:19:03 UTC to 2016-08-11 00:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:39:03 UTC to 2016-08-11 00:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:59:03 UTC to 2016-08-11 00:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:19:03 UTC to 2016-08-11 01:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:39:03 UTC to 2016-08-11 01:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:59:02 UTC to 2016-08-11 01:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:19:02 UTC to 2016-08-11 02:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:39:02 UTC to 2016-08-11 02:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:59:03 UTC to 2016-08-11 02:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:19:02 UTC to 2016-08-11 03:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:39:02 UTC to 2016-08-11 03:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:59:03 UTC to 2016-08-11 03:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:19:02 UTC to 2016-08-11 04:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:39:02 UTC to 2016-08-11 04:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:59:02 UTC to 2016-08-11 04:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:19:02 UTC to 2016-08-11 05:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:39:02 UTC to 2016-08-11 05:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:59:02 UTC to 2016-08-11 05:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:19:02 UTC to 2016-08-11 06:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:39:02 UTC to 2016-08-11 06:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:59:02 UTC to 2016-08-11 06:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:19:02 UTC to 2016-08-11 07:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:39:02 UTC to 2016-08-11 07:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:59:02 UTC to 2016-08-11 07:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:19:02 UTC to 2016-08-11 08:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:39:02 UTC to 2016-08-11 08:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:59:02 UTC to 2016-08-11 08:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:19:02 UTC to 2016-08-11 09:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:39:02 UTC to 2016-08-11 09:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:59:02 UTC to 2016-08-11 09:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:19:02 UTC to 2016-08-11 10:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:39:02 UTC to 2016-08-11 10:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:59:02 UTC to 2016-08-11 10:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:19:02 UTC to 2016-08-11 11:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:39:02 UTC to 2016-08-11 11:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:59:02 UTC to 2016-08-11 11:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:19:02 UTC to 2016-08-11 12:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:39:02 UTC to 2016-08-11 12:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:59:02 UTC to 2016-08-11 12:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:19:02 UTC to 2016-08-11 13:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:39:02 UTC to 2016-08-11 13:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:59:02 UTC to 2016-08-11 13:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:19:02 UTC to 2016-08-11 14:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:39:02 UTC to 2016-08-11 14:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:59:02 UTC to 2016-08-11 14:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:19:02 UTC to 2016-08-11 15:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:39:02 UTC to 2016-08-11 15:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:59:02 UTC to 2016-08-11 15:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:19:02 UTC to 2016-08-11 16:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:39:02 UTC to 2016-08-11 16:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:59:02 UTC to 2016-08-11 16:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:19:02 UTC to 2016-08-11 17:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:39:02 UTC to 2016-08-11 17:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:59:02 UTC to 2016-08-11 17:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:19:02 UTC to 2016-08-11 18:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:39:02 UTC to 2016-08-11 18:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:59:02 UTC to 2016-08-11 18:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:19:02 UTC to 2016-08-11 19:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:39:02 UTC to 2016-08-11 19:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:59:02 UTC to 2016-08-11 19:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:19:02 UTC to 2016-08-11 20:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:39:02 UTC to 2016-08-11 20:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:59:02 UTC to 2016-08-11 20:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:19:02 UTC to 2016-08-11 21:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:39:02 UTC to 2016-08-11 21:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:59:02 UTC to 2016-08-11 21:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:19:02 UTC to 2016-08-11 22:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:39:02 UTC to 2016-08-11 22:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:59:02 UTC to 2016-08-11 22:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:19:02 UTC to 2016-08-11 23:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:39:02 UTC to 2016-08-11 23:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:59:02 UTC to 2016-08-11 23:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:19:02 UTC to 2016-08-12 00:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:39:02 UTC to 2016-08-12 00:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:59:02 UTC to 2016-08-12 00:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:19:02 UTC to 2016-08-12 01:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:39:02 UTC to 2016-08-12 01:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:59:02 UTC to 2016-08-12 01:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:19:02 UTC to 2016-08-12 02:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:39:02 UTC to 2016-08-12 02:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:59:02 UTC to 2016-08-12 02:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:19:02 UTC to 2016-08-12 03:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:39:01 UTC to 2016-08-12 03:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:59:02 UTC to 2016-08-12 03:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:19:01 UTC to 2016-08-12 04:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:39:01 UTC to 2016-08-12 04:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:59:01 UTC to 2016-08-12 04:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:19:01 UTC to 2016-08-12 05:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:39:01 UTC to 2016-08-12 05:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:59:01 UTC to 2016-08-12 05:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:19:01 UTC to 2016-08-12 06:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:39:01 UTC to 2016-08-12 06:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:59:01 UTC to 2016-08-12 06:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:19:01 UTC to 2016-08-12 07:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:39:01 UTC to 2016-08-12 07:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:59:01 UTC to 2016-08-12 07:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:19:01 UTC to 2016-08-12 08:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:39:01 UTC to 2016-08-12 08:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:59:01 UTC to 2016-08-12 08:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:19:01 UTC to 2016-08-12 09:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:39:01 UTC to 2016-08-12 09:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:59:01 UTC to 2016-08-12 09:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 10:19:01 UTC to 2016-08-12 10:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 10:39:01 UTC to 2016-08-12 10:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:00:31 UTC to 2016-08-13 00:00:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:10:30 UTC to 2016-08-13 00:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:30:31 UTC to 2016-08-13 00:30:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:50:30 UTC to 2016-08-13 00:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:10:30 UTC to 2016-08-13 01:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:30:31 UTC to 2016-08-13 01:30:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:50:30 UTC to 2016-08-13 01:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:10:31 UTC to 2016-08-13 02:10:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:30:30 UTC to 2016-08-13 02:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:50:30 UTC to 2016-08-13 02:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:10:30 UTC to 2016-08-13 03:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:30:30 UTC to 2016-08-13 03:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:50:30 UTC to 2016-08-13 03:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:10:30 UTC to 2016-08-13 04:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:30:30 UTC to 2016-08-13 04:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:50:30 UTC to 2016-08-13 04:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:10:30 UTC to 2016-08-13 05:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:30:30 UTC to 2016-08-13 05:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:50:30 UTC to 2016-08-13 05:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:10:30 UTC to 2016-08-13 06:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:30:30 UTC to 2016-08-13 06:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:50:30 UTC to 2016-08-13 06:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:10:30 UTC to 2016-08-13 07:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:30:30 UTC to 2016-08-13 07:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:50:30 UTC to 2016-08-13 07:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:10:30 UTC to 2016-08-13 08:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:30:30 UTC to 2016-08-13 08:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:50:30 UTC to 2016-08-13 08:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:10:30 UTC to 2016-08-13 09:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:30:30 UTC to 2016-08-13 09:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:50:30 UTC to 2016-08-13 09:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:10:30 UTC to 2016-08-13 10:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:30:30 UTC to 2016-08-13 10:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:50:30 UTC to 2016-08-13 10:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:10:30 UTC to 2016-08-13 11:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:30:30 UTC to 2016-08-13 11:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:50:30 UTC to 2016-08-13 11:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:10:30 UTC to 2016-08-13 12:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:30:30 UTC to 2016-08-13 12:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:50:30 UTC to 2016-08-13 12:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:10:30 UTC to 2016-08-13 13:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:30:30 UTC to 2016-08-13 13:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:50:30 UTC to 2016-08-13 13:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:10:30 UTC to 2016-08-13 14:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:30:30 UTC to 2016-08-13 14:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:50:30 UTC to 2016-08-13 14:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:10:30 UTC to 2016-08-13 15:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:30:30 UTC to 2016-08-13 15:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:50:30 UTC to 2016-08-13 15:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:10:30 UTC to 2016-08-13 16:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:30:30 UTC to 2016-08-13 16:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:50:30 UTC to 2016-08-13 16:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:10:30 UTC to 2016-08-13 17:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:30:30 UTC to 2016-08-13 17:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:50:30 UTC to 2016-08-13 17:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:10:30 UTC to 2016-08-13 18:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:30:30 UTC to 2016-08-13 18:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:50:30 UTC to 2016-08-13 18:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:10:30 UTC to 2016-08-13 19:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:30:30 UTC to 2016-08-13 19:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:50:30 UTC to 2016-08-13 19:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:10:30 UTC to 2016-08-13 20:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:30:30 UTC to 2016-08-13 20:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:50:30 UTC to 2016-08-13 20:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:10:30 UTC to 2016-08-13 21:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:30:30 UTC to 2016-08-13 21:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:50:30 UTC to 2016-08-13 21:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:10:30 UTC to 2016-08-13 22:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:30:30 UTC to 2016-08-13 22:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:50:30 UTC to 2016-08-13 22:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:10:30 UTC to 2016-08-13 23:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:30:30 UTC to 2016-08-13 23:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:50:30 UTC to 2016-08-13 23:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:10:30 UTC to 2016-08-14 00:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:30:30 UTC to 2016-08-14 00:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:50:30 UTC to 2016-08-14 00:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:10:30 UTC to 2016-08-14 01:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:30:30 UTC to 2016-08-14 01:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:50:30 UTC to 2016-08-14 01:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:10:29 UTC to 2016-08-14 02:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:30:30 UTC to 2016-08-14 02:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:50:30 UTC to 2016-08-14 02:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:10:30 UTC to 2016-08-14 03:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:30:30 UTC to 2016-08-14 03:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:50:30 UTC to 2016-08-14 03:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:10:30 UTC to 2016-08-14 04:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:30:30 UTC to 2016-08-14 04:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:50:29 UTC to 2016-08-14 04:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:10:29 UTC to 2016-08-14 05:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:30:29 UTC to 2016-08-14 05:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:50:29 UTC to 2016-08-14 05:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:10:29 UTC to 2016-08-14 06:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:30:29 UTC to 2016-08-14 06:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:50:30 UTC to 2016-08-14 06:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:10:29 UTC to 2016-08-14 07:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:30:29 UTC to 2016-08-14 07:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:50:29 UTC to 2016-08-14 07:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:10:29 UTC to 2016-08-14 08:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:30:29 UTC to 2016-08-14 08:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:50:29 UTC to 2016-08-14 08:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:10:29 UTC to 2016-08-14 09:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:30:29 UTC to 2016-08-14 09:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:50:29 UTC to 2016-08-14 09:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:10:29 UTC to 2016-08-14 10:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:30:29 UTC to 2016-08-14 10:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:50:29 UTC to 2016-08-14 10:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:10:29 UTC to 2016-08-14 11:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:30:29 UTC to 2016-08-14 11:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:50:29 UTC to 2016-08-14 11:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 19:36:09 UTC to 2016-08-15 19:36:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 19:46:09 UTC to 2016-08-15 19:46:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:06:09 UTC to 2016-08-15 20:06:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:26:09 UTC to 2016-08-15 20:26:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:46:08 UTC to 2016-08-15 20:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:06:08 UTC to 2016-08-15 21:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:26:08 UTC to 2016-08-15 21:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:46:08 UTC to 2016-08-15 21:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:06:08 UTC to 2016-08-15 22:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:26:08 UTC to 2016-08-15 22:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:46:08 UTC to 2016-08-15 22:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:06:08 UTC to 2016-08-15 23:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:26:12 UTC to 2016-08-15 23:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:46:09 UTC to 2016-08-15 23:46:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:06:08 UTC to 2016-08-16 00:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:26:08 UTC to 2016-08-16 00:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:46:08 UTC to 2016-08-16 00:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:06:08 UTC to 2016-08-16 01:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:26:08 UTC to 2016-08-16 01:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:46:08 UTC to 2016-08-16 01:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:06:08 UTC to 2016-08-16 02:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:26:08 UTC to 2016-08-16 02:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:46:08 UTC to 2016-08-16 02:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:06:08 UTC to 2016-08-16 03:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:26:08 UTC to 2016-08-16 03:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:46:08 UTC to 2016-08-16 03:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:06:08 UTC to 2016-08-16 04:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:26:08 UTC to 2016-08-16 04:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:46:08 UTC to 2016-08-16 04:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:06:08 UTC to 2016-08-16 05:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:26:08 UTC to 2016-08-16 05:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:46:08 UTC to 2016-08-16 05:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:06:08 UTC to 2016-08-16 06:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:26:08 UTC to 2016-08-16 06:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:46:08 UTC to 2016-08-16 06:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:06:08 UTC to 2016-08-16 07:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:26:08 UTC to 2016-08-16 07:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:46:08 UTC to 2016-08-16 07:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:06:08 UTC to 2016-08-16 08:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:26:08 UTC to 2016-08-16 08:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:46:08 UTC to 2016-08-16 08:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:06:08 UTC to 2016-08-16 09:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:26:08 UTC to 2016-08-16 09:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:46:08 UTC to 2016-08-16 09:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:06:08 UTC to 2016-08-16 10:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:26:08 UTC to 2016-08-16 10:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:46:08 UTC to 2016-08-16 10:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:06:08 UTC to 2016-08-16 11:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:26:08 UTC to 2016-08-16 11:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:46:08 UTC to 2016-08-16 11:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:06:08 UTC to 2016-08-16 12:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:26:08 UTC to 2016-08-16 12:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:46:08 UTC to 2016-08-16 12:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:06:08 UTC to 2016-08-16 13:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:26:08 UTC to 2016-08-16 13:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:46:08 UTC to 2016-08-16 13:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:06:08 UTC to 2016-08-16 14:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:26:08 UTC to 2016-08-16 14:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:46:08 UTC to 2016-08-16 14:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:06:08 UTC to 2016-08-16 15:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:26:08 UTC to 2016-08-16 15:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:46:08 UTC to 2016-08-16 15:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:06:08 UTC to 2016-08-16 16:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:26:08 UTC to 2016-08-16 16:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:46:08 UTC to 2016-08-16 16:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:06:08 UTC to 2016-08-16 17:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:26:08 UTC to 2016-08-16 17:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:46:08 UTC to 2016-08-16 17:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:06:08 UTC to 2016-08-16 18:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:26:08 UTC to 2016-08-16 18:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:46:08 UTC to 2016-08-16 18:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:06:08 UTC to 2016-08-16 19:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:26:08 UTC to 2016-08-16 19:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:46:08 UTC to 2016-08-16 19:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:06:08 UTC to 2016-08-16 20:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:26:08 UTC to 2016-08-16 20:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:46:08 UTC to 2016-08-16 20:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:06:08 UTC to 2016-08-16 21:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:26:08 UTC to 2016-08-16 21:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:46:08 UTC to 2016-08-16 21:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:06:08 UTC to 2016-08-16 22:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:26:08 UTC to 2016-08-16 22:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:46:08 UTC to 2016-08-16 22:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:06:09 UTC to 2016-08-16 23:06:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:26:08 UTC to 2016-08-16 23:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:46:08 UTC to 2016-08-16 23:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:06:07 UTC to 2016-08-17 00:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:26:07 UTC to 2016-08-17 00:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:46:07 UTC to 2016-08-17 00:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:06:07 UTC to 2016-08-17 01:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:26:07 UTC to 2016-08-17 01:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:46:07 UTC to 2016-08-17 01:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:06:08 UTC to 2016-08-17 02:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:26:07 UTC to 2016-08-17 02:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:46:07 UTC to 2016-08-17 02:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:06:07 UTC to 2016-08-17 03:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:26:07 UTC to 2016-08-17 03:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:46:07 UTC to 2016-08-17 03:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:06:07 UTC to 2016-08-17 04:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:26:07 UTC to 2016-08-17 04:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:46:07 UTC to 2016-08-17 04:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 05:06:07 UTC to 2016-08-17 05:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 23:32:11 UTC to 2016-08-17 23:32:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 23:42:11 UTC to 2016-08-17 23:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:02:11 UTC to 2016-08-18 00:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:22:11 UTC to 2016-08-18 00:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:42:11 UTC to 2016-08-18 00:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:02:11 UTC to 2016-08-18 01:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:22:11 UTC to 2016-08-18 01:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:42:11 UTC to 2016-08-18 01:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:02:11 UTC to 2016-08-18 02:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:22:11 UTC to 2016-08-18 02:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:42:11 UTC to 2016-08-18 02:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:02:11 UTC to 2016-08-18 03:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:22:11 UTC to 2016-08-18 03:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:42:11 UTC to 2016-08-18 03:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:02:11 UTC to 2016-08-18 04:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:22:11 UTC to 2016-08-18 04:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:42:11 UTC to 2016-08-18 04:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:02:11 UTC to 2016-08-18 05:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:22:11 UTC to 2016-08-18 05:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:42:11 UTC to 2016-08-18 05:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:02:11 UTC to 2016-08-18 06:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:22:11 UTC to 2016-08-18 06:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:42:11 UTC to 2016-08-18 06:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:02:11 UTC to 2016-08-18 07:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:22:11 UTC to 2016-08-18 07:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:42:11 UTC to 2016-08-18 07:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:02:11 UTC to 2016-08-18 08:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:22:11 UTC to 2016-08-18 08:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:42:11 UTC to 2016-08-18 08:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:02:11 UTC to 2016-08-18 09:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:22:11 UTC to 2016-08-18 09:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:42:11 UTC to 2016-08-18 09:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:02:11 UTC to 2016-08-18 10:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:22:11 UTC to 2016-08-18 10:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:42:11 UTC to 2016-08-18 10:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:02:11 UTC to 2016-08-18 11:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:22:11 UTC to 2016-08-18 11:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:42:11 UTC to 2016-08-18 11:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:02:11 UTC to 2016-08-18 12:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:22:11 UTC to 2016-08-18 12:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:42:11 UTC to 2016-08-18 12:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:02:11 UTC to 2016-08-18 13:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:22:11 UTC to 2016-08-18 13:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:42:11 UTC to 2016-08-18 13:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:02:11 UTC to 2016-08-18 14:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:22:11 UTC to 2016-08-18 14:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:42:11 UTC to 2016-08-18 14:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:02:11 UTC to 2016-08-18 15:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:22:11 UTC to 2016-08-18 15:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:42:11 UTC to 2016-08-18 15:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:02:11 UTC to 2016-08-18 16:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:22:11 UTC to 2016-08-18 16:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:42:12 UTC to 2016-08-18 16:42:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:02:11 UTC to 2016-08-18 17:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:22:11 UTC to 2016-08-18 17:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:42:11 UTC to 2016-08-18 17:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 18:02:11 UTC to 2016-08-18 18:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 18:22:11 UTC to 2016-08-18 18:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:02:11 UTC to 2016-08-18 19:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:22:11 UTC to 2016-08-18 19:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:42:11 UTC to 2016-08-18 19:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:02:10 UTC to 2016-08-18 20:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:22:11 UTC to 2016-08-18 20:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:42:10 UTC to 2016-08-18 20:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:02:11 UTC to 2016-08-18 21:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:22:10 UTC to 2016-08-18 21:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:42:10 UTC to 2016-08-18 21:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:02:10 UTC to 2016-08-18 22:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:22:11 UTC to 2016-08-18 22:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:42:10 UTC to 2016-08-18 22:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:02:10 UTC to 2016-08-18 23:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:22:10 UTC to 2016-08-18 23:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:42:10 UTC to 2016-08-18 23:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:02:10 UTC to 2016-08-19 00:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:22:10 UTC to 2016-08-19 00:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:42:10 UTC to 2016-08-19 00:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:02:10 UTC to 2016-08-19 01:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:22:11 UTC to 2016-08-19 01:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:42:10 UTC to 2016-08-19 01:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:02:10 UTC to 2016-08-19 02:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:22:10 UTC to 2016-08-19 02:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:42:10 UTC to 2016-08-19 02:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:02:10 UTC to 2016-08-19 03:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:22:10 UTC to 2016-08-19 03:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:42:10 UTC to 2016-08-19 03:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:02:10 UTC to 2016-08-19 04:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:22:10 UTC to 2016-08-19 04:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:42:10 UTC to 2016-08-19 04:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:02:10 UTC to 2016-08-19 05:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:22:10 UTC to 2016-08-19 05:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:42:10 UTC to 2016-08-19 05:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:02:10 UTC to 2016-08-19 06:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:22:10 UTC to 2016-08-19 06:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:42:10 UTC to 2016-08-19 06:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:02:10 UTC to 2016-08-19 07:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:22:10 UTC to 2016-08-19 07:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:42:10 UTC to 2016-08-19 07:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:02:10 UTC to 2016-08-19 08:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:22:10 UTC to 2016-08-19 08:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:42:10 UTC to 2016-08-19 08:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:02:10 UTC to 2016-08-19 09:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:22:10 UTC to 2016-08-19 09:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:42:10 UTC to 2016-08-19 09:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:02:10 UTC to 2016-08-19 10:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:22:10 UTC to 2016-08-19 10:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:42:10 UTC to 2016-08-19 10:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:02:10 UTC to 2016-08-19 11:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:22:10 UTC to 2016-08-19 11:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:42:10 UTC to 2016-08-19 11:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:02:10 UTC to 2016-08-19 12:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:22:10 UTC to 2016-08-19 12:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:42:10 UTC to 2016-08-19 12:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:02:10 UTC to 2016-08-19 13:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:22:11 UTC to 2016-08-19 13:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:42:13 UTC to 2016-08-19 13:42:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:02:10 UTC to 2016-08-19 14:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:22:10 UTC to 2016-08-19 14:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:42:10 UTC to 2016-08-19 14:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:02:10 UTC to 2016-08-19 15:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:22:10 UTC to 2016-08-19 15:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:42:10 UTC to 2016-08-19 15:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:02:10 UTC to 2016-08-19 16:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:22:10 UTC to 2016-08-19 16:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:42:10 UTC to 2016-08-19 16:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:02:10 UTC to 2016-08-19 17:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:22:10 UTC to 2016-08-19 17:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:42:10 UTC to 2016-08-19 17:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:02:10 UTC to 2016-08-19 18:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:22:10 UTC to 2016-08-19 18:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:42:10 UTC to 2016-08-19 18:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:02:10 UTC to 2016-08-19 19:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:22:10 UTC to 2016-08-19 19:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:42:10 UTC to 2016-08-19 19:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:02:10 UTC to 2016-08-19 20:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:22:10 UTC to 2016-08-19 20:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:42:10 UTC to 2016-08-19 20:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:02:12 UTC to 2016-08-19 21:02:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:22:10 UTC to 2016-08-19 21:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:42:10 UTC to 2016-08-19 21:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:02:10 UTC to 2016-08-19 22:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:22:10 UTC to 2016-08-19 22:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:42:09 UTC to 2016-08-19 22:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:02:09 UTC to 2016-08-19 23:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:22:10 UTC to 2016-08-19 23:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:42:09 UTC to 2016-08-19 23:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:02:09 UTC to 2016-08-20 00:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:22:09 UTC to 2016-08-20 00:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:42:10 UTC to 2016-08-20 00:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:02:09 UTC to 2016-08-20 01:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:22:09 UTC to 2016-08-20 01:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:42:09 UTC to 2016-08-20 01:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:02:09 UTC to 2016-08-20 02:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:22:10 UTC to 2016-08-20 02:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:42:09 UTC to 2016-08-20 02:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:02:09 UTC to 2016-08-20 03:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:22:10 UTC to 2016-08-20 03:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:42:09 UTC to 2016-08-20 03:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:02:09 UTC to 2016-08-20 04:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:22:09 UTC to 2016-08-20 04:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:42:10 UTC to 2016-08-20 04:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:02:09 UTC to 2016-08-20 05:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:22:09 UTC to 2016-08-20 05:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:42:09 UTC to 2016-08-20 05:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:02:09 UTC to 2016-08-20 06:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:22:09 UTC to 2016-08-20 06:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:42:09 UTC to 2016-08-20 06:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:02:09 UTC to 2016-08-20 07:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:22:09 UTC to 2016-08-20 07:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:42:09 UTC to 2016-08-20 07:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:02:09 UTC to 2016-08-20 08:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:22:09 UTC to 2016-08-20 08:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:42:09 UTC to 2016-08-20 08:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:02:09 UTC to 2016-08-20 09:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:22:09 UTC to 2016-08-20 09:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:42:09 UTC to 2016-08-20 09:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:02:09 UTC to 2016-08-20 10:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:22:09 UTC to 2016-08-20 10:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:42:09 UTC to 2016-08-20 10:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:02:09 UTC to 2016-08-20 11:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:22:09 UTC to 2016-08-20 11:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:42:09 UTC to 2016-08-20 11:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:02:09 UTC to 2016-08-20 12:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:22:09 UTC to 2016-08-20 12:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:42:09 UTC to 2016-08-20 12:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:02:09 UTC to 2016-08-20 13:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:22:09 UTC to 2016-08-20 13:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:42:09 UTC to 2016-08-20 13:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:02:09 UTC to 2016-08-20 14:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:22:09 UTC to 2016-08-20 14:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:42:09 UTC to 2016-08-20 14:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:02:09 UTC to 2016-08-20 15:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:22:09 UTC to 2016-08-20 15:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:42:09 UTC to 2016-08-20 15:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:02:09 UTC to 2016-08-20 16:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:22:09 UTC to 2016-08-20 16:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:42:09 UTC to 2016-08-20 16:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:02:09 UTC to 2016-08-20 17:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:22:09 UTC to 2016-08-20 17:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:42:09 UTC to 2016-08-20 17:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:02:09 UTC to 2016-08-20 18:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:22:09 UTC to 2016-08-20 18:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:42:09 UTC to 2016-08-20 18:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:02:09 UTC to 2016-08-20 19:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:22:09 UTC to 2016-08-20 19:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:42:09 UTC to 2016-08-20 19:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:02:09 UTC to 2016-08-20 20:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:22:09 UTC to 2016-08-20 20:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:42:09 UTC to 2016-08-20 20:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:02:09 UTC to 2016-08-20 21:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:22:09 UTC to 2016-08-20 21:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:42:09 UTC to 2016-08-20 21:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:02:09 UTC to 2016-08-20 22:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:22:09 UTC to 2016-08-20 22:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:42:09 UTC to 2016-08-20 22:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:02:09 UTC to 2016-08-20 23:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:22:09 UTC to 2016-08-20 23:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:42:09 UTC to 2016-08-20 23:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:02:09 UTC to 2016-08-21 00:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:22:09 UTC to 2016-08-21 00:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:42:09 UTC to 2016-08-21 00:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:02:09 UTC to 2016-08-21 01:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:22:09 UTC to 2016-08-21 01:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:42:09 UTC to 2016-08-21 01:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:02:09 UTC to 2016-08-21 02:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:22:08 UTC to 2016-08-21 02:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:42:09 UTC to 2016-08-21 02:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:02:09 UTC to 2016-08-21 03:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:22:09 UTC to 2016-08-21 03:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:42:09 UTC to 2016-08-21 03:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:02:08 UTC to 2016-08-21 04:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:22:09 UTC to 2016-08-21 04:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:42:09 UTC to 2016-08-21 04:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:02:08 UTC to 2016-08-21 05:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:22:08 UTC to 2016-08-21 05:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:42:08 UTC to 2016-08-21 05:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:02:08 UTC to 2016-08-21 06:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:22:08 UTC to 2016-08-21 06:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:42:08 UTC to 2016-08-21 06:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:02:08 UTC to 2016-08-21 07:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:22:08 UTC to 2016-08-21 07:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:42:08 UTC to 2016-08-21 07:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:02:09 UTC to 2016-08-21 08:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:22:08 UTC to 2016-08-21 08:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:42:08 UTC to 2016-08-21 08:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:02:08 UTC to 2016-08-21 09:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:22:08 UTC to 2016-08-21 09:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:42:08 UTC to 2016-08-21 09:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:02:08 UTC to 2016-08-21 10:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:22:08 UTC to 2016-08-21 10:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:42:08 UTC to 2016-08-21 10:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:02:08 UTC to 2016-08-21 11:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:22:08 UTC to 2016-08-21 11:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:42:08 UTC to 2016-08-21 11:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:02:08 UTC to 2016-08-21 12:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:22:08 UTC to 2016-08-21 12:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:42:08 UTC to 2016-08-21 12:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:02:08 UTC to 2016-08-21 13:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:22:08 UTC to 2016-08-21 13:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:42:08 UTC to 2016-08-21 13:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:02:08 UTC to 2016-08-21 14:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:22:09 UTC to 2016-08-21 14:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:42:08 UTC to 2016-08-21 14:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:02:08 UTC to 2016-08-21 15:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:22:08 UTC to 2016-08-21 15:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:42:08 UTC to 2016-08-21 15:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:02:08 UTC to 2016-08-21 16:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:22:08 UTC to 2016-08-21 16:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:42:08 UTC to 2016-08-21 16:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:02:08 UTC to 2016-08-21 17:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:22:08 UTC to 2016-08-21 17:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:42:08 UTC to 2016-08-21 17:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:02:08 UTC to 2016-08-21 18:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:22:08 UTC to 2016-08-21 18:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:42:08 UTC to 2016-08-21 18:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:02:08 UTC to 2016-08-21 19:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:22:08 UTC to 2016-08-21 19:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:42:08 UTC to 2016-08-21 19:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:02:08 UTC to 2016-08-21 20:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:22:08 UTC to 2016-08-21 20:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:42:08 UTC to 2016-08-21 20:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:02:08 UTC to 2016-08-21 21:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:22:08 UTC to 2016-08-21 21:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:42:08 UTC to 2016-08-21 21:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:02:08 UTC to 2016-08-21 22:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:22:08 UTC to 2016-08-21 22:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:42:08 UTC to 2016-08-21 22:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:02:08 UTC to 2016-08-21 23:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:22:08 UTC to 2016-08-21 23:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:42:08 UTC to 2016-08-21 23:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:02:08 UTC to 2016-08-22 00:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:22:08 UTC to 2016-08-22 00:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:42:08 UTC to 2016-08-22 00:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:02:08 UTC to 2016-08-22 01:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:22:08 UTC to 2016-08-22 01:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:42:08 UTC to 2016-08-22 01:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:02:08 UTC to 2016-08-22 02:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:22:08 UTC to 2016-08-22 02:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:42:08 UTC to 2016-08-22 02:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:02:08 UTC to 2016-08-22 03:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:22:08 UTC to 2016-08-22 03:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:42:08 UTC to 2016-08-22 03:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:02:08 UTC to 2016-08-22 04:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:22:08 UTC to 2016-08-22 04:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:42:08 UTC to 2016-08-22 04:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:02:08 UTC to 2016-08-22 05:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:22:08 UTC to 2016-08-22 05:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:42:08 UTC to 2016-08-22 05:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:02:08 UTC to 2016-08-22 06:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:22:08 UTC to 2016-08-22 06:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:42:07 UTC to 2016-08-22 06:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:02:08 UTC to 2016-08-22 07:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:22:08 UTC to 2016-08-22 07:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:42:07 UTC to 2016-08-22 07:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:02:07 UTC to 2016-08-22 08:02:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:22:07 UTC to 2016-08-22 08:22:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:42:07 UTC to 2016-08-22 08:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:02:07 UTC to 2016-08-22 09:02:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:22:07 UTC to 2016-08-22 09:22:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:42:07 UTC to 2016-08-22 09:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:07:43 UTC to 2016-08-23 00:08:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:17:43 UTC to 2016-08-23 00:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:37:43 UTC to 2016-08-23 00:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:57:43 UTC to 2016-08-23 00:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:17:43 UTC to 2016-08-23 01:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:37:43 UTC to 2016-08-23 01:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:57:43 UTC to 2016-08-23 01:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:17:43 UTC to 2016-08-23 02:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:37:43 UTC to 2016-08-23 02:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:57:43 UTC to 2016-08-23 02:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:18:34 UTC to 2016-08-23 03:18:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:18:51 UTC to 2016-08-23 03:19:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:05 UTC to 2016-08-23 03:19:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:15 UTC to 2016-08-23 03:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:24 UTC to 2016-08-23 03:19:44 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:37:43 UTC to 2016-08-23 03:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:57:44 UTC to 2016-08-23 03:58:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:17:43 UTC to 2016-08-23 04:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:37:43 UTC to 2016-08-23 04:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:57:43 UTC to 2016-08-23 04:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:17:43 UTC to 2016-08-23 05:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:37:43 UTC to 2016-08-23 05:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:57:43 UTC to 2016-08-23 05:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:17:43 UTC to 2016-08-23 06:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:37:43 UTC to 2016-08-23 06:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:57:43 UTC to 2016-08-23 06:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:17:43 UTC to 2016-08-23 07:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:37:43 UTC to 2016-08-23 07:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:57:43 UTC to 2016-08-23 07:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:17:43 UTC to 2016-08-23 08:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:37:43 UTC to 2016-08-23 08:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:57:43 UTC to 2016-08-23 08:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:17:43 UTC to 2016-08-23 09:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:37:43 UTC to 2016-08-23 09:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:57:43 UTC to 2016-08-23 09:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:17:43 UTC to 2016-08-23 10:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:37:43 UTC to 2016-08-23 10:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:57:43 UTC to 2016-08-23 10:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:17:43 UTC to 2016-08-23 11:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:37:43 UTC to 2016-08-23 11:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:57:43 UTC to 2016-08-23 11:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:17:43 UTC to 2016-08-23 12:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:37:43 UTC to 2016-08-23 12:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:57:43 UTC to 2016-08-23 12:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:17:43 UTC to 2016-08-23 13:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:37:43 UTC to 2016-08-23 13:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:57:43 UTC to 2016-08-23 13:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:17:43 UTC to 2016-08-23 14:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:37:43 UTC to 2016-08-23 14:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:57:43 UTC to 2016-08-23 14:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:17:44 UTC to 2016-08-23 15:18:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:37:43 UTC to 2016-08-23 15:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:57:43 UTC to 2016-08-23 15:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:17:43 UTC to 2016-08-23 16:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:37:42 UTC to 2016-08-23 16:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:57:43 UTC to 2016-08-23 16:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:17:43 UTC to 2016-08-23 17:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:37:43 UTC to 2016-08-23 17:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:57:42 UTC to 2016-08-23 17:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:17:44 UTC to 2016-08-23 18:18:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:37:42 UTC to 2016-08-23 18:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:57:42 UTC to 2016-08-23 18:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:17:42 UTC to 2016-08-23 19:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:37:42 UTC to 2016-08-23 19:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:57:42 UTC to 2016-08-23 19:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:17:42 UTC to 2016-08-23 20:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:37:42 UTC to 2016-08-23 20:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:57:42 UTC to 2016-08-23 20:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:17:42 UTC to 2016-08-23 21:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:37:42 UTC to 2016-08-23 21:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:57:42 UTC to 2016-08-23 21:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:17:42 UTC to 2016-08-23 22:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:37:42 UTC to 2016-08-23 22:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:57:42 UTC to 2016-08-23 22:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:17:42 UTC to 2016-08-23 23:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:37:42 UTC to 2016-08-23 23:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:57:42 UTC to 2016-08-23 23:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:17:42 UTC to 2016-08-24 00:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:37:42 UTC to 2016-08-24 00:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:57:42 UTC to 2016-08-24 00:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:17:42 UTC to 2016-08-24 01:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:37:42 UTC to 2016-08-24 01:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:57:42 UTC to 2016-08-24 01:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:17:42 UTC to 2016-08-24 02:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:37:42 UTC to 2016-08-24 02:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:57:42 UTC to 2016-08-24 02:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:17:42 UTC to 2016-08-24 03:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:37:42 UTC to 2016-08-24 03:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:57:42 UTC to 2016-08-24 03:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:17:42 UTC to 2016-08-24 04:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:37:42 UTC to 2016-08-24 04:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:57:42 UTC to 2016-08-24 04:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:17:42 UTC to 2016-08-24 05:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:37:42 UTC to 2016-08-24 05:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:57:42 UTC to 2016-08-24 05:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:17:42 UTC to 2016-08-24 06:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:37:42 UTC to 2016-08-24 06:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:57:42 UTC to 2016-08-24 06:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:17:42 UTC to 2016-08-24 07:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:37:42 UTC to 2016-08-24 07:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:57:42 UTC to 2016-08-24 07:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:17:42 UTC to 2016-08-24 08:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:37:42 UTC to 2016-08-24 08:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:57:42 UTC to 2016-08-24 08:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:17:42 UTC to 2016-08-24 09:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:37:42 UTC to 2016-08-24 09:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:57:42 UTC to 2016-08-24 09:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:17:42 UTC to 2016-08-24 10:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:37:42 UTC to 2016-08-24 10:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:57:42 UTC to 2016-08-24 10:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:17:42 UTC to 2016-08-24 11:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:37:42 UTC to 2016-08-24 11:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:57:42 UTC to 2016-08-24 11:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:17:42 UTC to 2016-08-24 12:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:37:42 UTC to 2016-08-24 12:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:57:42 UTC to 2016-08-24 12:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:17:42 UTC to 2016-08-24 13:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:37:42 UTC to 2016-08-24 13:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:57:42 UTC to 2016-08-24 13:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:17:42 UTC to 2016-08-24 14:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:37:42 UTC to 2016-08-24 14:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:57:42 UTC to 2016-08-24 14:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:17:42 UTC to 2016-08-24 15:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:37:42 UTC to 2016-08-24 15:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:57:42 UTC to 2016-08-24 15:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:17:42 UTC to 2016-08-24 16:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:37:42 UTC to 2016-08-24 16:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:57:42 UTC to 2016-08-24 16:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:17:42 UTC to 2016-08-24 17:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:37:43 UTC to 2016-08-24 17:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:57:42 UTC to 2016-08-24 17:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:17:42 UTC to 2016-08-24 18:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:37:42 UTC to 2016-08-24 18:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:57:42 UTC to 2016-08-24 18:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:17:42 UTC to 2016-08-24 19:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:37:42 UTC to 2016-08-24 19:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:57:42 UTC to 2016-08-24 19:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:17:42 UTC to 2016-08-24 20:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:37:42 UTC to 2016-08-24 20:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:57:42 UTC to 2016-08-24 20:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:17:41 UTC to 2016-08-24 21:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:37:41 UTC to 2016-08-24 21:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:57:41 UTC to 2016-08-24 21:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:17:41 UTC to 2016-08-24 22:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:37:41 UTC to 2016-08-24 22:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:57:41 UTC to 2016-08-24 22:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:17:41 UTC to 2016-08-24 23:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:37:41 UTC to 2016-08-24 23:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:57:41 UTC to 2016-08-24 23:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:17:41 UTC to 2016-08-25 00:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:37:41 UTC to 2016-08-25 00:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:57:41 UTC to 2016-08-25 00:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:17:41 UTC to 2016-08-25 01:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:37:42 UTC to 2016-08-25 01:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:57:41 UTC to 2016-08-25 01:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:17:41 UTC to 2016-08-25 02:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:37:46 UTC to 2016-08-25 02:38:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:57:41 UTC to 2016-08-25 02:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:17:41 UTC to 2016-08-25 03:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:37:41 UTC to 2016-08-25 03:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:57:41 UTC to 2016-08-25 03:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:17:41 UTC to 2016-08-25 04:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:37:41 UTC to 2016-08-25 04:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:57:41 UTC to 2016-08-25 04:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:17:41 UTC to 2016-08-25 05:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:37:41 UTC to 2016-08-25 05:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:57:43 UTC to 2016-08-25 05:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:17:41 UTC to 2016-08-25 06:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:37:41 UTC to 2016-08-25 06:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:57:41 UTC to 2016-08-25 06:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:17:41 UTC to 2016-08-25 07:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:37:41 UTC to 2016-08-25 07:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:57:41 UTC to 2016-08-25 07:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:17:41 UTC to 2016-08-25 08:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:37:41 UTC to 2016-08-25 08:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:57:41 UTC to 2016-08-25 08:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:17:41 UTC to 2016-08-25 09:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:37:41 UTC to 2016-08-25 09:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:57:41 UTC to 2016-08-25 09:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:17:41 UTC to 2016-08-25 10:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:37:41 UTC to 2016-08-25 10:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:57:41 UTC to 2016-08-25 10:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:17:41 UTC to 2016-08-25 11:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:37:41 UTC to 2016-08-25 11:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:57:41 UTC to 2016-08-25 11:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:17:41 UTC to 2016-08-25 12:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:37:41 UTC to 2016-08-25 12:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:57:41 UTC to 2016-08-25 12:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:17:41 UTC to 2016-08-25 13:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:37:41 UTC to 2016-08-25 13:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:57:41 UTC to 2016-08-25 13:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:17:41 UTC to 2016-08-25 14:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:37:41 UTC to 2016-08-25 14:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:57:42 UTC to 2016-08-25 14:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:17:41 UTC to 2016-08-25 15:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:37:41 UTC to 2016-08-25 15:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:57:41 UTC to 2016-08-25 15:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:17:42 UTC to 2016-08-25 16:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:37:41 UTC to 2016-08-25 16:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:57:41 UTC to 2016-08-25 16:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:17:41 UTC to 2016-08-25 17:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:37:41 UTC to 2016-08-25 17:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:57:41 UTC to 2016-08-25 17:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:17:41 UTC to 2016-08-25 18:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:37:41 UTC to 2016-08-25 18:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:57:41 UTC to 2016-08-25 18:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:17:41 UTC to 2016-08-25 19:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:37:41 UTC to 2016-08-25 19:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:57:41 UTC to 2016-08-25 19:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:17:41 UTC to 2016-08-25 20:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:37:41 UTC to 2016-08-25 20:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:57:41 UTC to 2016-08-25 20:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:17:41 UTC to 2016-08-25 21:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:37:41 UTC to 2016-08-25 21:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:57:40 UTC to 2016-08-25 21:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:17:41 UTC to 2016-08-25 22:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:37:40 UTC to 2016-08-25 22:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:57:40 UTC to 2016-08-25 22:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:17:50 UTC to 2016-08-25 23:18:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:18:02 UTC to 2016-08-25 23:18:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:27:41 UTC to 2016-08-25 23:28:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:37:41 UTC to 2016-08-25 23:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:57:40 UTC to 2016-08-25 23:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:17:41 UTC to 2016-08-26 00:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:37:40 UTC to 2016-08-26 00:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:57:40 UTC to 2016-08-26 00:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:17:41 UTC to 2016-08-26 01:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:37:40 UTC to 2016-08-26 01:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:57:40 UTC to 2016-08-26 01:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:17:40 UTC to 2016-08-26 02:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:37:40 UTC to 2016-08-26 02:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:57:40 UTC to 2016-08-26 02:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:17:40 UTC to 2016-08-26 03:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:37:40 UTC to 2016-08-26 03:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:57:40 UTC to 2016-08-26 03:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:17:40 UTC to 2016-08-26 04:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:37:40 UTC to 2016-08-26 04:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:57:40 UTC to 2016-08-26 04:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:17:40 UTC to 2016-08-26 05:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:37:40 UTC to 2016-08-26 05:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:57:40 UTC to 2016-08-26 05:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:17:40 UTC to 2016-08-26 06:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:37:40 UTC to 2016-08-26 06:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:57:40 UTC to 2016-08-26 06:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:17:40 UTC to 2016-08-26 07:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:37:40 UTC to 2016-08-26 07:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:57:40 UTC to 2016-08-26 07:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:17:40 UTC to 2016-08-26 08:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:37:40 UTC to 2016-08-26 08:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:57:40 UTC to 2016-08-26 08:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:17:40 UTC to 2016-08-26 09:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:37:40 UTC to 2016-08-26 09:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:57:40 UTC to 2016-08-26 09:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:17:40 UTC to 2016-08-26 10:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:37:40 UTC to 2016-08-26 10:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:57:40 UTC to 2016-08-26 10:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:17:40 UTC to 2016-08-26 11:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:37:40 UTC to 2016-08-26 11:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:57:40 UTC to 2016-08-26 11:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:17:40 UTC to 2016-08-26 12:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:37:40 UTC to 2016-08-26 12:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:57:40 UTC to 2016-08-26 12:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:17:40 UTC to 2016-08-26 13:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:37:40 UTC to 2016-08-26 13:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:57:40 UTC to 2016-08-26 13:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:17:40 UTC to 2016-08-26 14:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:37:40 UTC to 2016-08-26 14:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:57:40 UTC to 2016-08-26 14:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:17:40 UTC to 2016-08-26 15:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:37:40 UTC to 2016-08-26 15:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:57:41 UTC to 2016-08-26 15:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:17:40 UTC to 2016-08-26 16:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:37:40 UTC to 2016-08-26 16:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:57:40 UTC to 2016-08-26 16:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:17:40 UTC to 2016-08-26 17:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:37:40 UTC to 2016-08-26 17:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:57:40 UTC to 2016-08-26 17:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:17:40 UTC to 2016-08-26 18:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:37:40 UTC to 2016-08-26 18:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:57:40 UTC to 2016-08-26 18:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:17:40 UTC to 2016-08-26 19:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:37:40 UTC to 2016-08-26 19:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:57:40 UTC to 2016-08-26 19:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:17:40 UTC to 2016-08-26 20:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:37:40 UTC to 2016-08-26 20:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:57:40 UTC to 2016-08-26 20:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:17:40 UTC to 2016-08-26 21:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:37:40 UTC to 2016-08-26 21:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:57:40 UTC to 2016-08-26 21:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:17:40 UTC to 2016-08-26 22:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:37:40 UTC to 2016-08-26 22:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:57:40 UTC to 2016-08-26 22:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:17:40 UTC to 2016-08-26 23:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:37:40 UTC to 2016-08-26 23:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:57:40 UTC to 2016-08-26 23:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:17:40 UTC to 2016-08-27 00:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:37:40 UTC to 2016-08-27 00:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:57:40 UTC to 2016-08-27 00:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:17:40 UTC to 2016-08-27 01:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:37:39 UTC to 2016-08-27 01:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:57:40 UTC to 2016-08-27 01:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:17:39 UTC to 2016-08-27 02:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:37:39 UTC to 2016-08-27 02:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:57:39 UTC to 2016-08-27 02:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:17:39 UTC to 2016-08-27 03:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:37:39 UTC to 2016-08-27 03:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:57:39 UTC to 2016-08-27 03:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:17:39 UTC to 2016-08-27 04:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:37:39 UTC to 2016-08-27 04:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:57:39 UTC to 2016-08-27 04:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:17:39 UTC to 2016-08-27 05:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:37:39 UTC to 2016-08-27 05:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:57:39 UTC to 2016-08-27 05:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:17:39 UTC to 2016-08-27 06:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:37:39 UTC to 2016-08-27 06:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:57:39 UTC to 2016-08-27 06:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:17:39 UTC to 2016-08-27 07:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:37:39 UTC to 2016-08-27 07:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:57:39 UTC to 2016-08-27 07:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:17:39 UTC to 2016-08-27 08:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:37:39 UTC to 2016-08-27 08:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:57:39 UTC to 2016-08-27 08:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:17:39 UTC to 2016-08-27 09:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:37:39 UTC to 2016-08-27 09:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:57:39 UTC to 2016-08-27 09:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:17:39 UTC to 2016-08-27 10:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:37:39 UTC to 2016-08-27 10:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:57:39 UTC to 2016-08-27 10:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:17:39 UTC to 2016-08-27 11:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:37:39 UTC to 2016-08-27 11:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:57:39 UTC to 2016-08-27 11:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:17:39 UTC to 2016-08-27 12:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:37:39 UTC to 2016-08-27 12:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:57:39 UTC to 2016-08-27 12:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:17:39 UTC to 2016-08-27 13:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:37:39 UTC to 2016-08-27 13:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:57:39 UTC to 2016-08-27 13:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:17:39 UTC to 2016-08-27 14:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:37:39 UTC to 2016-08-27 14:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:57:39 UTC to 2016-08-27 14:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:17:39 UTC to 2016-08-27 15:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:37:39 UTC to 2016-08-27 15:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:57:39 UTC to 2016-08-27 15:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:17:39 UTC to 2016-08-27 16:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:37:39 UTC to 2016-08-27 16:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:57:39 UTC to 2016-08-27 16:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:17:39 UTC to 2016-08-27 17:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:37:39 UTC to 2016-08-27 17:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:57:39 UTC to 2016-08-27 17:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:17:39 UTC to 2016-08-27 18:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:37:39 UTC to 2016-08-27 18:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:57:39 UTC to 2016-08-27 18:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:17:39 UTC to 2016-08-27 19:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:37:39 UTC to 2016-08-27 19:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:57:39 UTC to 2016-08-27 19:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:17:39 UTC to 2016-08-27 20:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:37:39 UTC to 2016-08-27 20:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:57:39 UTC to 2016-08-27 20:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:17:39 UTC to 2016-08-27 21:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:37:39 UTC to 2016-08-27 21:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:57:39 UTC to 2016-08-27 21:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:17:39 UTC to 2016-08-27 22:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:37:39 UTC to 2016-08-27 22:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:57:39 UTC to 2016-08-27 22:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:17:39 UTC to 2016-08-27 23:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:37:39 UTC to 2016-08-27 23:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:57:39 UTC to 2016-08-27 23:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:17:39 UTC to 2016-08-28 00:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:37:39 UTC to 2016-08-28 00:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:57:39 UTC to 2016-08-28 00:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:17:39 UTC to 2016-08-28 01:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:37:39 UTC to 2016-08-28 01:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:57:39 UTC to 2016-08-28 01:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:17:39 UTC to 2016-08-28 02:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:37:39 UTC to 2016-08-28 02:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:57:39 UTC to 2016-08-28 02:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:17:39 UTC to 2016-08-28 03:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:37:39 UTC to 2016-08-28 03:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:57:39 UTC to 2016-08-28 03:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:17:39 UTC to 2016-08-28 04:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:37:39 UTC to 2016-08-28 04:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:57:39 UTC to 2016-08-28 04:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:12:03 UTC to 2016-08-29 01:12:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:22:03 UTC to 2016-08-29 01:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:42:03 UTC to 2016-08-29 01:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:02:03 UTC to 2016-08-29 02:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:22:03 UTC to 2016-08-29 02:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:42:03 UTC to 2016-08-29 02:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:02:03 UTC to 2016-08-29 03:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:22:03 UTC to 2016-08-29 03:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:42:03 UTC to 2016-08-29 03:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:02:03 UTC to 2016-08-29 04:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:22:03 UTC to 2016-08-29 04:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:42:03 UTC to 2016-08-29 04:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:02:03 UTC to 2016-08-29 05:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:22:03 UTC to 2016-08-29 05:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:42:03 UTC to 2016-08-29 05:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:02:03 UTC to 2016-08-29 06:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:22:03 UTC to 2016-08-29 06:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:42:03 UTC to 2016-08-29 06:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:02:03 UTC to 2016-08-29 07:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:22:03 UTC to 2016-08-29 07:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:42:03 UTC to 2016-08-29 07:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:02:03 UTC to 2016-08-29 08:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:22:03 UTC to 2016-08-29 08:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:42:03 UTC to 2016-08-29 08:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:02:03 UTC to 2016-08-29 09:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:22:03 UTC to 2016-08-29 09:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:42:03 UTC to 2016-08-29 09:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:02:03 UTC to 2016-08-29 10:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:22:03 UTC to 2016-08-29 10:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:42:03 UTC to 2016-08-29 10:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:02:03 UTC to 2016-08-29 11:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:22:03 UTC to 2016-08-29 11:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:42:03 UTC to 2016-08-29 11:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:02:03 UTC to 2016-08-29 12:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:22:03 UTC to 2016-08-29 12:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:42:03 UTC to 2016-08-29 12:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:02:03 UTC to 2016-08-29 13:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:22:03 UTC to 2016-08-29 13:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:42:03 UTC to 2016-08-29 13:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:02:03 UTC to 2016-08-29 14:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:22:03 UTC to 2016-08-29 14:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:42:03 UTC to 2016-08-29 14:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:02:03 UTC to 2016-08-29 15:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:22:03 UTC to 2016-08-29 15:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:42:03 UTC to 2016-08-29 15:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:02:03 UTC to 2016-08-29 16:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:22:03 UTC to 2016-08-29 16:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:42:03 UTC to 2016-08-29 16:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:02:03 UTC to 2016-08-29 17:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:22:03 UTC to 2016-08-29 17:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:42:03 UTC to 2016-08-29 17:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:02:03 UTC to 2016-08-29 18:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:22:03 UTC to 2016-08-29 18:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:42:03 UTC to 2016-08-29 18:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:02:03 UTC to 2016-08-29 19:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:22:03 UTC to 2016-08-29 19:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:42:03 UTC to 2016-08-29 19:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:02:03 UTC to 2016-08-29 20:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:22:03 UTC to 2016-08-29 20:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:42:03 UTC to 2016-08-29 20:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:02:03 UTC to 2016-08-29 21:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:22:02 UTC to 2016-08-29 21:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:42:03 UTC to 2016-08-29 21:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:02:03 UTC to 2016-08-29 22:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:22:02 UTC to 2016-08-29 22:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:42:02 UTC to 2016-08-29 22:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:02:02 UTC to 2016-08-29 23:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:22:02 UTC to 2016-08-29 23:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:42:03 UTC to 2016-08-29 23:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:02:02 UTC to 2016-08-30 00:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:22:02 UTC to 2016-08-30 00:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:42:03 UTC to 2016-08-30 00:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:02:02 UTC to 2016-08-30 01:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:22:02 UTC to 2016-08-30 01:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:42:02 UTC to 2016-08-30 01:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:02:02 UTC to 2016-08-30 02:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:22:02 UTC to 2016-08-30 02:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:42:02 UTC to 2016-08-30 02:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:02:02 UTC to 2016-08-30 03:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:22:02 UTC to 2016-08-30 03:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:42:02 UTC to 2016-08-30 03:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:02:02 UTC to 2016-08-30 04:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:22:02 UTC to 2016-08-30 04:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:42:02 UTC to 2016-08-30 04:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:02:02 UTC to 2016-08-30 05:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:22:02 UTC to 2016-08-30 05:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:42:02 UTC to 2016-08-30 05:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:02:02 UTC to 2016-08-30 06:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:22:02 UTC to 2016-08-30 06:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:42:02 UTC to 2016-08-30 06:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:02:02 UTC to 2016-08-30 07:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:22:02 UTC to 2016-08-30 07:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:42:02 UTC to 2016-08-30 07:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:02:02 UTC to 2016-08-30 08:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:22:02 UTC to 2016-08-30 08:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:42:02 UTC to 2016-08-30 08:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:02:02 UTC to 2016-08-30 09:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:22:02 UTC to 2016-08-30 09:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:42:02 UTC to 2016-08-30 09:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:02:02 UTC to 2016-08-30 10:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:22:02 UTC to 2016-08-30 10:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:42:02 UTC to 2016-08-30 10:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:02:02 UTC to 2016-08-30 11:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:22:02 UTC to 2016-08-30 11:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:42:02 UTC to 2016-08-30 11:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:02:02 UTC to 2016-08-30 12:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:22:02 UTC to 2016-08-30 12:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:42:02 UTC to 2016-08-30 12:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:02:02 UTC to 2016-08-30 13:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:22:02 UTC to 2016-08-30 13:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:42:02 UTC to 2016-08-30 13:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 14:02:02 UTC to 2016-08-30 14:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 14:22:02 UTC to 2016-08-30 14:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:01:16 UTC to 2016-08-31 00:01:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:21:16 UTC to 2016-08-31 00:21:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:41:15 UTC to 2016-08-31 00:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:01:16 UTC to 2016-08-31 01:01:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:21:15 UTC to 2016-08-31 01:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:41:16 UTC to 2016-08-31 01:41:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:01:15 UTC to 2016-08-31 02:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:21:15 UTC to 2016-08-31 02:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:41:15 UTC to 2016-08-31 02:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:01:15 UTC to 2016-08-31 03:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:21:15 UTC to 2016-08-31 03:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:41:15 UTC to 2016-08-31 03:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:01:15 UTC to 2016-08-31 04:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:21:15 UTC to 2016-08-31 04:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:41:15 UTC to 2016-08-31 04:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:01:15 UTC to 2016-08-31 05:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:21:15 UTC to 2016-08-31 05:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:41:15 UTC to 2016-08-31 05:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:01:15 UTC to 2016-08-31 06:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:21:15 UTC to 2016-08-31 06:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:41:15 UTC to 2016-08-31 06:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:01:15 UTC to 2016-08-31 07:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:21:15 UTC to 2016-08-31 07:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:41:15 UTC to 2016-08-31 07:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:01:15 UTC to 2016-08-31 08:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:21:15 UTC to 2016-08-31 08:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:41:15 UTC to 2016-08-31 08:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:01:15 UTC to 2016-08-31 09:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:21:15 UTC to 2016-08-31 09:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:41:15 UTC to 2016-08-31 09:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:01:15 UTC to 2016-08-31 10:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:21:15 UTC to 2016-08-31 10:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:41:15 UTC to 2016-08-31 10:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:01:15 UTC to 2016-08-31 11:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:21:15 UTC to 2016-08-31 11:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:41:15 UTC to 2016-08-31 11:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:01:15 UTC to 2016-08-31 12:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:21:15 UTC to 2016-08-31 12:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:41:15 UTC to 2016-08-31 12:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:01:15 UTC to 2016-08-31 13:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:21:15 UTC to 2016-08-31 13:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:41:15 UTC to 2016-08-31 13:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:01:15 UTC to 2016-08-31 14:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:21:15 UTC to 2016-08-31 14:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:41:15 UTC to 2016-08-31 14:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:01:15 UTC to 2016-08-31 15:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:21:15 UTC to 2016-08-31 15:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:41:15 UTC to 2016-08-31 15:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:01:15 UTC to 2016-08-31 16:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:21:15 UTC to 2016-08-31 16:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:41:15 UTC to 2016-08-31 16:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:01:15 UTC to 2016-08-31 17:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:21:15 UTC to 2016-08-31 17:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:41:15 UTC to 2016-08-31 17:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:01:15 UTC to 2016-08-31 18:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:21:15 UTC to 2016-08-31 18:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:41:15 UTC to 2016-08-31 18:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:01:15 UTC to 2016-08-31 19:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:21:15 UTC to 2016-08-31 19:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:41:15 UTC to 2016-08-31 19:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:01:15 UTC to 2016-08-31 20:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:21:15 UTC to 2016-08-31 20:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:41:15 UTC to 2016-08-31 20:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:01:15 UTC to 2016-08-31 21:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:21:15 UTC to 2016-08-31 21:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:41:15 UTC to 2016-08-31 21:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:01:15 UTC to 2016-08-31 22:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:21:15 UTC to 2016-08-31 22:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:41:15 UTC to 2016-08-31 22:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:01:15 UTC to 2016-08-31 23:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:21:15 UTC to 2016-08-31 23:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:41:15 UTC to 2016-08-31 23:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:01:15 UTC to 2016-09-01 00:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:21:15 UTC to 2016-09-01 00:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:41:15 UTC to 2016-09-01 00:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:01:15 UTC to 2016-09-01 01:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:21:15 UTC to 2016-09-01 01:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:41:15 UTC to 2016-09-01 01:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:01:15 UTC to 2016-09-01 02:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:21:15 UTC to 2016-09-01 02:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:41:15 UTC to 2016-09-01 02:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:01:14 UTC to 2016-09-01 03:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:21:14 UTC to 2016-09-01 03:21:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:41:15 UTC to 2016-09-01 03:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:01:14 UTC to 2016-09-01 04:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:21:15 UTC to 2016-09-01 04:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:41:15 UTC to 2016-09-01 04:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 05:01:14 UTC to 2016-09-01 05:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 05:21:14 UTC to 2016-09-01 05:21:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 14:32:57 UTC to 2016-08-02 14:33:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 14:42:57 UTC to 2016-08-02 14:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 14:52:57 UTC to 2016-08-02 14:53:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:02:57 UTC to 2016-08-02 15:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:22:57 UTC to 2016-08-02 15:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 15:42:57 UTC to 2016-08-02 15:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:02:57 UTC to 2016-08-02 16:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:22:57 UTC to 2016-08-02 16:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 16:42:57 UTC to 2016-08-02 16:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:02:57 UTC to 2016-08-02 17:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:22:57 UTC to 2016-08-02 17:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 17:42:57 UTC to 2016-08-02 17:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:02:57 UTC to 2016-08-02 18:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:22:57 UTC to 2016-08-02 18:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 18:42:57 UTC to 2016-08-02 18:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:02:57 UTC to 2016-08-02 19:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:22:57 UTC to 2016-08-02 19:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 19:42:57 UTC to 2016-08-02 19:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:02:57 UTC to 2016-08-02 20:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:22:57 UTC to 2016-08-02 20:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 20:42:57 UTC to 2016-08-02 20:43:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:02:57 UTC to 2016-08-02 21:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:22:57 UTC to 2016-08-02 21:23:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 21:42:56 UTC to 2016-08-02 21:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:02:56 UTC to 2016-08-02 22:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:22:56 UTC to 2016-08-02 22:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 22:42:56 UTC to 2016-08-02 22:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:02:57 UTC to 2016-08-02 23:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:22:56 UTC to 2016-08-02 23:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-02 23:42:56 UTC to 2016-08-02 23:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:02:56 UTC to 2016-08-03 00:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:22:56 UTC to 2016-08-03 00:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 00:42:56 UTC to 2016-08-03 00:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:02:56 UTC to 2016-08-03 01:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:22:56 UTC to 2016-08-03 01:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 01:42:56 UTC to 2016-08-03 01:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:02:56 UTC to 2016-08-03 02:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:22:56 UTC to 2016-08-03 02:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 02:42:56 UTC to 2016-08-03 02:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:02:56 UTC to 2016-08-03 03:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:22:56 UTC to 2016-08-03 03:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 03:42:56 UTC to 2016-08-03 03:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:02:56 UTC to 2016-08-03 04:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:22:56 UTC to 2016-08-03 04:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 04:42:56 UTC to 2016-08-03 04:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:02:56 UTC to 2016-08-03 05:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:22:56 UTC to 2016-08-03 05:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 05:42:56 UTC to 2016-08-03 05:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:02:56 UTC to 2016-08-03 06:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:22:56 UTC to 2016-08-03 06:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 06:42:56 UTC to 2016-08-03 06:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:02:56 UTC to 2016-08-03 07:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:22:56 UTC to 2016-08-03 07:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 07:42:56 UTC to 2016-08-03 07:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:02:56 UTC to 2016-08-03 08:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:22:56 UTC to 2016-08-03 08:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 08:42:56 UTC to 2016-08-03 08:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:02:56 UTC to 2016-08-03 09:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:22:56 UTC to 2016-08-03 09:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 09:42:56 UTC to 2016-08-03 09:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:02:56 UTC to 2016-08-03 10:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:22:56 UTC to 2016-08-03 10:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 10:42:56 UTC to 2016-08-03 10:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:02:56 UTC to 2016-08-03 11:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:22:56 UTC to 2016-08-03 11:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 11:42:56 UTC to 2016-08-03 11:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:02:56 UTC to 2016-08-03 12:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:22:56 UTC to 2016-08-03 12:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 12:42:56 UTC to 2016-08-03 12:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:02:56 UTC to 2016-08-03 13:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:22:56 UTC to 2016-08-03 13:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 13:42:56 UTC to 2016-08-03 13:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:02:56 UTC to 2016-08-03 14:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:22:56 UTC to 2016-08-03 14:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 14:42:56 UTC to 2016-08-03 14:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:02:56 UTC to 2016-08-03 15:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:22:56 UTC to 2016-08-03 15:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 15:42:56 UTC to 2016-08-03 15:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:02:56 UTC to 2016-08-03 16:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:22:56 UTC to 2016-08-03 16:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 16:42:56 UTC to 2016-08-03 16:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:02:56 UTC to 2016-08-03 17:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:22:56 UTC to 2016-08-03 17:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 17:42:56 UTC to 2016-08-03 17:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:02:56 UTC to 2016-08-03 18:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:22:56 UTC to 2016-08-03 18:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 18:42:56 UTC to 2016-08-03 18:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:02:56 UTC to 2016-08-03 19:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:22:56 UTC to 2016-08-03 19:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 19:42:56 UTC to 2016-08-03 19:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:02:56 UTC to 2016-08-03 20:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:22:56 UTC to 2016-08-03 20:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 20:42:56 UTC to 2016-08-03 20:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:02:56 UTC to 2016-08-03 21:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:22:56 UTC to 2016-08-03 21:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 21:42:56 UTC to 2016-08-03 21:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:02:56 UTC to 2016-08-03 22:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:22:56 UTC to 2016-08-03 22:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 22:42:56 UTC to 2016-08-03 22:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:02:55 UTC to 2016-08-03 23:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:22:55 UTC to 2016-08-03 23:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-03 23:42:55 UTC to 2016-08-03 23:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:02:56 UTC to 2016-08-04 00:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:22:55 UTC to 2016-08-04 00:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 00:42:56 UTC to 2016-08-04 00:43:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:02:55 UTC to 2016-08-04 01:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:22:55 UTC to 2016-08-04 01:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 01:42:55 UTC to 2016-08-04 01:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:02:55 UTC to 2016-08-04 02:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:22:56 UTC to 2016-08-04 02:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 02:42:55 UTC to 2016-08-04 02:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:02:55 UTC to 2016-08-04 03:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:22:55 UTC to 2016-08-04 03:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 03:42:55 UTC to 2016-08-04 03:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:02:55 UTC to 2016-08-04 04:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:22:55 UTC to 2016-08-04 04:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 04:42:55 UTC to 2016-08-04 04:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:02:55 UTC to 2016-08-04 05:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:22:55 UTC to 2016-08-04 05:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 05:42:55 UTC to 2016-08-04 05:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:02:55 UTC to 2016-08-04 06:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:22:55 UTC to 2016-08-04 06:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 06:42:55 UTC to 2016-08-04 06:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:02:55 UTC to 2016-08-04 07:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:22:55 UTC to 2016-08-04 07:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 07:42:55 UTC to 2016-08-04 07:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:02:55 UTC to 2016-08-04 08:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:22:55 UTC to 2016-08-04 08:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 08:42:55 UTC to 2016-08-04 08:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:02:55 UTC to 2016-08-04 09:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:22:55 UTC to 2016-08-04 09:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 09:42:55 UTC to 2016-08-04 09:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:02:55 UTC to 2016-08-04 10:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:22:55 UTC to 2016-08-04 10:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 10:42:55 UTC to 2016-08-04 10:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:02:55 UTC to 2016-08-04 11:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:22:55 UTC to 2016-08-04 11:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 11:42:55 UTC to 2016-08-04 11:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:02:55 UTC to 2016-08-04 12:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:22:55 UTC to 2016-08-04 12:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 12:42:55 UTC to 2016-08-04 12:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:02:55 UTC to 2016-08-04 13:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:22:55 UTC to 2016-08-04 13:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 13:42:55 UTC to 2016-08-04 13:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 14:02:55 UTC to 2016-08-04 14:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:02:55 UTC to 2016-08-04 15:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:22:55 UTC to 2016-08-04 15:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 15:42:55 UTC to 2016-08-04 15:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:02:55 UTC to 2016-08-04 16:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:22:55 UTC to 2016-08-04 16:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 16:42:55 UTC to 2016-08-04 16:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:02:55 UTC to 2016-08-04 17:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:22:55 UTC to 2016-08-04 17:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 17:42:55 UTC to 2016-08-04 17:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:02:55 UTC to 2016-08-04 18:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:22:55 UTC to 2016-08-04 18:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 18:42:55 UTC to 2016-08-04 18:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:02:55 UTC to 2016-08-04 19:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:22:55 UTC to 2016-08-04 19:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 19:42:55 UTC to 2016-08-04 19:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:02:55 UTC to 2016-08-04 20:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:22:55 UTC to 2016-08-04 20:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 20:42:55 UTC to 2016-08-04 20:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:02:56 UTC to 2016-08-04 21:03:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:22:55 UTC to 2016-08-04 21:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 21:42:55 UTC to 2016-08-04 21:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:02:55 UTC to 2016-08-04 22:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:22:55 UTC to 2016-08-04 22:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 22:42:55 UTC to 2016-08-04 22:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:02:57 UTC to 2016-08-04 23:03:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:22:56 UTC to 2016-08-04 23:23:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-04 23:42:55 UTC to 2016-08-04 23:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:02:55 UTC to 2016-08-05 00:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:22:55 UTC to 2016-08-05 00:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 00:42:55 UTC to 2016-08-05 00:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:02:55 UTC to 2016-08-05 01:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:22:55 UTC to 2016-08-05 01:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 01:42:55 UTC to 2016-08-05 01:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:02:55 UTC to 2016-08-05 02:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:22:55 UTC to 2016-08-05 02:23:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 02:42:55 UTC to 2016-08-05 02:43:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:02:55 UTC to 2016-08-05 03:03:15 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:22:54 UTC to 2016-08-05 03:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 03:42:54 UTC to 2016-08-05 03:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:02:54 UTC to 2016-08-05 04:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:22:54 UTC to 2016-08-05 04:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 04:42:54 UTC to 2016-08-05 04:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:02:54 UTC to 2016-08-05 05:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:22:54 UTC to 2016-08-05 05:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 05:42:54 UTC to 2016-08-05 05:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:02:54 UTC to 2016-08-05 06:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:22:54 UTC to 2016-08-05 06:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 06:42:54 UTC to 2016-08-05 06:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:02:54 UTC to 2016-08-05 07:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:22:54 UTC to 2016-08-05 07:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 07:42:54 UTC to 2016-08-05 07:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:02:54 UTC to 2016-08-05 08:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:22:54 UTC to 2016-08-05 08:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 08:42:54 UTC to 2016-08-05 08:43:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 09:02:54 UTC to 2016-08-05 09:03:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 09:22:54 UTC to 2016-08-05 09:23:14 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:05:28 UTC to 2016-08-05 23:05:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:15:30 UTC to 2016-08-05 23:15:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:35:28 UTC to 2016-08-05 23:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-05 23:55:28 UTC to 2016-08-05 23:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:15:28 UTC to 2016-08-06 00:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:35:28 UTC to 2016-08-06 00:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 00:55:28 UTC to 2016-08-06 00:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:15:28 UTC to 2016-08-06 01:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:35:28 UTC to 2016-08-06 01:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 01:55:28 UTC to 2016-08-06 01:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:15:28 UTC to 2016-08-06 02:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:35:28 UTC to 2016-08-06 02:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 02:55:28 UTC to 2016-08-06 02:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:15:28 UTC to 2016-08-06 03:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:35:28 UTC to 2016-08-06 03:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 03:55:28 UTC to 2016-08-06 03:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:15:28 UTC to 2016-08-06 04:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:35:28 UTC to 2016-08-06 04:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 04:55:28 UTC to 2016-08-06 04:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:15:28 UTC to 2016-08-06 05:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:35:28 UTC to 2016-08-06 05:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 05:55:28 UTC to 2016-08-06 05:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:15:28 UTC to 2016-08-06 06:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:35:28 UTC to 2016-08-06 06:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 06:55:28 UTC to 2016-08-06 06:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:15:28 UTC to 2016-08-06 07:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:35:28 UTC to 2016-08-06 07:35:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 07:55:28 UTC to 2016-08-06 07:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:15:28 UTC to 2016-08-06 08:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:35:27 UTC to 2016-08-06 08:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 08:55:28 UTC to 2016-08-06 08:55:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:15:28 UTC to 2016-08-06 09:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:35:27 UTC to 2016-08-06 09:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 09:55:27 UTC to 2016-08-06 09:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:15:27 UTC to 2016-08-06 10:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:35:27 UTC to 2016-08-06 10:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 10:55:27 UTC to 2016-08-06 10:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:15:28 UTC to 2016-08-06 11:15:48 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:35:27 UTC to 2016-08-06 11:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 11:55:27 UTC to 2016-08-06 11:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:15:27 UTC to 2016-08-06 12:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:35:27 UTC to 2016-08-06 12:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 12:55:27 UTC to 2016-08-06 12:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:15:27 UTC to 2016-08-06 13:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:35:27 UTC to 2016-08-06 13:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 13:55:27 UTC to 2016-08-06 13:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:15:27 UTC to 2016-08-06 14:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:35:27 UTC to 2016-08-06 14:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 14:55:27 UTC to 2016-08-06 14:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:15:27 UTC to 2016-08-06 15:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:35:27 UTC to 2016-08-06 15:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 15:55:27 UTC to 2016-08-06 15:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:15:27 UTC to 2016-08-06 16:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:35:27 UTC to 2016-08-06 16:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 16:55:27 UTC to 2016-08-06 16:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:15:27 UTC to 2016-08-06 17:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:35:27 UTC to 2016-08-06 17:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 17:55:27 UTC to 2016-08-06 17:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:15:27 UTC to 2016-08-06 18:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:35:27 UTC to 2016-08-06 18:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 18:55:27 UTC to 2016-08-06 18:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:15:27 UTC to 2016-08-06 19:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:35:27 UTC to 2016-08-06 19:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 19:55:27 UTC to 2016-08-06 19:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:15:27 UTC to 2016-08-06 20:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:35:27 UTC to 2016-08-06 20:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 20:55:27 UTC to 2016-08-06 20:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:15:27 UTC to 2016-08-06 21:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:35:27 UTC to 2016-08-06 21:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 21:55:27 UTC to 2016-08-06 21:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:15:27 UTC to 2016-08-06 22:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:35:27 UTC to 2016-08-06 22:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 22:55:27 UTC to 2016-08-06 22:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:15:27 UTC to 2016-08-06 23:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:35:27 UTC to 2016-08-06 23:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-06 23:55:27 UTC to 2016-08-06 23:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:15:27 UTC to 2016-08-07 00:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:35:27 UTC to 2016-08-07 00:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 00:55:27 UTC to 2016-08-07 00:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:15:27 UTC to 2016-08-07 01:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:35:27 UTC to 2016-08-07 01:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 01:55:27 UTC to 2016-08-07 01:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:15:27 UTC to 2016-08-07 02:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:35:27 UTC to 2016-08-07 02:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 02:55:27 UTC to 2016-08-07 02:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:15:27 UTC to 2016-08-07 03:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:35:27 UTC to 2016-08-07 03:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 03:55:27 UTC to 2016-08-07 03:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:15:27 UTC to 2016-08-07 04:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:35:27 UTC to 2016-08-07 04:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 04:55:27 UTC to 2016-08-07 04:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:15:27 UTC to 2016-08-07 05:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:35:27 UTC to 2016-08-07 05:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 05:55:27 UTC to 2016-08-07 05:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:15:27 UTC to 2016-08-07 06:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:35:27 UTC to 2016-08-07 06:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 06:55:27 UTC to 2016-08-07 06:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:15:27 UTC to 2016-08-07 07:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:35:27 UTC to 2016-08-07 07:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 07:55:27 UTC to 2016-08-07 07:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:15:27 UTC to 2016-08-07 08:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:35:27 UTC to 2016-08-07 08:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 08:55:27 UTC to 2016-08-07 08:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:15:27 UTC to 2016-08-07 09:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:35:27 UTC to 2016-08-07 09:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 09:55:27 UTC to 2016-08-07 09:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:15:27 UTC to 2016-08-07 10:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:35:27 UTC to 2016-08-07 10:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 10:55:27 UTC to 2016-08-07 10:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:15:27 UTC to 2016-08-07 11:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:35:27 UTC to 2016-08-07 11:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 11:55:27 UTC to 2016-08-07 11:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:15:27 UTC to 2016-08-07 12:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:35:27 UTC to 2016-08-07 12:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 12:55:27 UTC to 2016-08-07 12:55:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:15:27 UTC to 2016-08-07 13:15:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:35:26 UTC to 2016-08-07 13:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 13:55:26 UTC to 2016-08-07 13:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:15:26 UTC to 2016-08-07 14:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:35:26 UTC to 2016-08-07 14:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 14:55:26 UTC to 2016-08-07 14:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:15:26 UTC to 2016-08-07 15:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:35:27 UTC to 2016-08-07 15:35:47 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 15:55:26 UTC to 2016-08-07 15:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:15:26 UTC to 2016-08-07 16:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:35:26 UTC to 2016-08-07 16:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 16:55:26 UTC to 2016-08-07 16:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:15:26 UTC to 2016-08-07 17:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:35:26 UTC to 2016-08-07 17:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 17:55:26 UTC to 2016-08-07 17:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:15:26 UTC to 2016-08-07 18:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:35:26 UTC to 2016-08-07 18:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 18:55:26 UTC to 2016-08-07 18:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:15:26 UTC to 2016-08-07 19:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:35:26 UTC to 2016-08-07 19:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 19:55:26 UTC to 2016-08-07 19:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:15:26 UTC to 2016-08-07 20:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:35:26 UTC to 2016-08-07 20:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 20:55:26 UTC to 2016-08-07 20:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:15:26 UTC to 2016-08-07 21:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:35:26 UTC to 2016-08-07 21:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 21:55:26 UTC to 2016-08-07 21:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:15:26 UTC to 2016-08-07 22:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:35:26 UTC to 2016-08-07 22:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 22:55:26 UTC to 2016-08-07 22:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:15:26 UTC to 2016-08-07 23:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:35:26 UTC to 2016-08-07 23:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-07 23:55:26 UTC to 2016-08-07 23:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:15:26 UTC to 2016-08-08 00:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:35:26 UTC to 2016-08-08 00:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 00:55:26 UTC to 2016-08-08 00:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:15:26 UTC to 2016-08-08 01:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:35:26 UTC to 2016-08-08 01:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 01:55:26 UTC to 2016-08-08 01:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:15:26 UTC to 2016-08-08 02:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:35:26 UTC to 2016-08-08 02:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 02:55:26 UTC to 2016-08-08 02:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:15:26 UTC to 2016-08-08 03:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:35:26 UTC to 2016-08-08 03:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 03:55:26 UTC to 2016-08-08 03:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:15:26 UTC to 2016-08-08 04:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:35:26 UTC to 2016-08-08 04:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 04:55:26 UTC to 2016-08-08 04:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:15:26 UTC to 2016-08-08 05:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:35:26 UTC to 2016-08-08 05:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 05:55:26 UTC to 2016-08-08 05:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:15:26 UTC to 2016-08-08 06:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:35:26 UTC to 2016-08-08 06:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 06:55:26 UTC to 2016-08-08 06:55:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 07:15:26 UTC to 2016-08-08 07:15:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-08 07:35:26 UTC to 2016-08-08 07:35:46 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:19:04 UTC to 2016-08-09 20:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:39:04 UTC to 2016-08-09 20:39:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 20:59:04 UTC to 2016-08-09 20:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:19:04 UTC to 2016-08-09 21:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:39:04 UTC to 2016-08-09 21:39:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 21:59:04 UTC to 2016-08-09 21:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:19:03 UTC to 2016-08-09 22:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:39:03 UTC to 2016-08-09 22:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 22:59:03 UTC to 2016-08-09 22:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:19:03 UTC to 2016-08-09 23:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:39:03 UTC to 2016-08-09 23:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-09 23:59:04 UTC to 2016-08-09 23:59:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:19:03 UTC to 2016-08-10 00:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:39:03 UTC to 2016-08-10 00:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 00:59:03 UTC to 2016-08-10 00:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:19:04 UTC to 2016-08-10 01:19:24 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:39:03 UTC to 2016-08-10 01:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 01:59:03 UTC to 2016-08-10 01:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:19:03 UTC to 2016-08-10 02:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:39:03 UTC to 2016-08-10 02:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 02:59:03 UTC to 2016-08-10 02:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:19:03 UTC to 2016-08-10 03:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:39:03 UTC to 2016-08-10 03:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 03:59:03 UTC to 2016-08-10 03:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:19:03 UTC to 2016-08-10 04:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:39:03 UTC to 2016-08-10 04:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 04:59:03 UTC to 2016-08-10 04:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:19:03 UTC to 2016-08-10 05:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:39:03 UTC to 2016-08-10 05:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 05:59:03 UTC to 2016-08-10 05:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:19:03 UTC to 2016-08-10 06:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:39:03 UTC to 2016-08-10 06:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 06:59:03 UTC to 2016-08-10 06:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:19:03 UTC to 2016-08-10 07:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:39:03 UTC to 2016-08-10 07:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 07:59:03 UTC to 2016-08-10 07:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:19:03 UTC to 2016-08-10 08:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:39:03 UTC to 2016-08-10 08:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 08:59:03 UTC to 2016-08-10 08:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:19:03 UTC to 2016-08-10 09:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:39:03 UTC to 2016-08-10 09:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 09:59:03 UTC to 2016-08-10 09:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:19:03 UTC to 2016-08-10 10:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:39:03 UTC to 2016-08-10 10:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 10:59:03 UTC to 2016-08-10 10:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:19:03 UTC to 2016-08-10 11:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:39:03 UTC to 2016-08-10 11:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 11:59:03 UTC to 2016-08-10 11:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:19:03 UTC to 2016-08-10 12:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:39:03 UTC to 2016-08-10 12:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 12:59:03 UTC to 2016-08-10 12:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:19:03 UTC to 2016-08-10 13:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:39:03 UTC to 2016-08-10 13:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 13:59:03 UTC to 2016-08-10 13:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:19:03 UTC to 2016-08-10 14:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:39:03 UTC to 2016-08-10 14:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 14:59:03 UTC to 2016-08-10 14:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:19:03 UTC to 2016-08-10 15:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:39:03 UTC to 2016-08-10 15:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 15:59:03 UTC to 2016-08-10 15:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:19:03 UTC to 2016-08-10 16:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:39:03 UTC to 2016-08-10 16:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 16:59:03 UTC to 2016-08-10 16:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:19:03 UTC to 2016-08-10 17:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:39:03 UTC to 2016-08-10 17:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 17:59:03 UTC to 2016-08-10 17:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:19:03 UTC to 2016-08-10 18:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:39:03 UTC to 2016-08-10 18:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 18:59:03 UTC to 2016-08-10 18:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:19:03 UTC to 2016-08-10 19:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:39:03 UTC to 2016-08-10 19:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 19:59:03 UTC to 2016-08-10 19:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:19:03 UTC to 2016-08-10 20:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:39:03 UTC to 2016-08-10 20:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 20:59:03 UTC to 2016-08-10 20:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:19:03 UTC to 2016-08-10 21:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:39:03 UTC to 2016-08-10 21:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 21:59:03 UTC to 2016-08-10 21:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:19:03 UTC to 2016-08-10 22:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:39:03 UTC to 2016-08-10 22:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 22:59:03 UTC to 2016-08-10 22:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:19:03 UTC to 2016-08-10 23:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:39:03 UTC to 2016-08-10 23:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-10 23:59:03 UTC to 2016-08-10 23:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:19:03 UTC to 2016-08-11 00:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:39:03 UTC to 2016-08-11 00:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 00:59:03 UTC to 2016-08-11 00:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:19:03 UTC to 2016-08-11 01:19:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:39:03 UTC to 2016-08-11 01:39:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 01:59:02 UTC to 2016-08-11 01:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:19:02 UTC to 2016-08-11 02:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:39:02 UTC to 2016-08-11 02:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 02:59:03 UTC to 2016-08-11 02:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:19:02 UTC to 2016-08-11 03:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:39:02 UTC to 2016-08-11 03:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 03:59:03 UTC to 2016-08-11 03:59:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:19:02 UTC to 2016-08-11 04:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:39:02 UTC to 2016-08-11 04:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 04:59:02 UTC to 2016-08-11 04:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:19:02 UTC to 2016-08-11 05:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:39:02 UTC to 2016-08-11 05:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 05:59:02 UTC to 2016-08-11 05:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:19:02 UTC to 2016-08-11 06:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:39:02 UTC to 2016-08-11 06:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 06:59:02 UTC to 2016-08-11 06:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:19:02 UTC to 2016-08-11 07:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:39:02 UTC to 2016-08-11 07:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 07:59:02 UTC to 2016-08-11 07:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:19:02 UTC to 2016-08-11 08:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:39:02 UTC to 2016-08-11 08:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 08:59:02 UTC to 2016-08-11 08:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:19:02 UTC to 2016-08-11 09:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:39:02 UTC to 2016-08-11 09:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 09:59:02 UTC to 2016-08-11 09:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:19:02 UTC to 2016-08-11 10:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:39:02 UTC to 2016-08-11 10:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 10:59:02 UTC to 2016-08-11 10:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:19:02 UTC to 2016-08-11 11:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:39:02 UTC to 2016-08-11 11:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 11:59:02 UTC to 2016-08-11 11:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:19:02 UTC to 2016-08-11 12:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:39:02 UTC to 2016-08-11 12:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 12:59:02 UTC to 2016-08-11 12:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:19:02 UTC to 2016-08-11 13:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:39:02 UTC to 2016-08-11 13:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 13:59:02 UTC to 2016-08-11 13:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:19:02 UTC to 2016-08-11 14:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:39:02 UTC to 2016-08-11 14:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 14:59:02 UTC to 2016-08-11 14:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:19:02 UTC to 2016-08-11 15:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:39:02 UTC to 2016-08-11 15:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 15:59:02 UTC to 2016-08-11 15:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:19:02 UTC to 2016-08-11 16:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:39:02 UTC to 2016-08-11 16:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 16:59:02 UTC to 2016-08-11 16:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:19:02 UTC to 2016-08-11 17:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:39:02 UTC to 2016-08-11 17:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 17:59:02 UTC to 2016-08-11 17:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:19:02 UTC to 2016-08-11 18:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:39:02 UTC to 2016-08-11 18:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 18:59:02 UTC to 2016-08-11 18:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:19:02 UTC to 2016-08-11 19:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:39:02 UTC to 2016-08-11 19:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 19:59:02 UTC to 2016-08-11 19:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:19:02 UTC to 2016-08-11 20:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:39:02 UTC to 2016-08-11 20:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 20:59:02 UTC to 2016-08-11 20:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:19:02 UTC to 2016-08-11 21:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:39:02 UTC to 2016-08-11 21:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 21:59:02 UTC to 2016-08-11 21:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:19:02 UTC to 2016-08-11 22:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:39:02 UTC to 2016-08-11 22:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 22:59:02 UTC to 2016-08-11 22:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:19:02 UTC to 2016-08-11 23:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:39:02 UTC to 2016-08-11 23:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-11 23:59:02 UTC to 2016-08-11 23:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:19:02 UTC to 2016-08-12 00:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:39:02 UTC to 2016-08-12 00:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 00:59:02 UTC to 2016-08-12 00:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:19:02 UTC to 2016-08-12 01:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:39:02 UTC to 2016-08-12 01:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 01:59:02 UTC to 2016-08-12 01:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:19:02 UTC to 2016-08-12 02:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:39:02 UTC to 2016-08-12 02:39:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 02:59:02 UTC to 2016-08-12 02:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:19:02 UTC to 2016-08-12 03:19:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:39:01 UTC to 2016-08-12 03:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 03:59:02 UTC to 2016-08-12 03:59:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:19:01 UTC to 2016-08-12 04:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:39:01 UTC to 2016-08-12 04:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 04:59:01 UTC to 2016-08-12 04:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:19:01 UTC to 2016-08-12 05:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:39:01 UTC to 2016-08-12 05:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 05:59:01 UTC to 2016-08-12 05:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:19:01 UTC to 2016-08-12 06:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:39:01 UTC to 2016-08-12 06:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 06:59:01 UTC to 2016-08-12 06:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:19:01 UTC to 2016-08-12 07:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:39:01 UTC to 2016-08-12 07:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 07:59:01 UTC to 2016-08-12 07:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:19:01 UTC to 2016-08-12 08:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:39:01 UTC to 2016-08-12 08:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 08:59:01 UTC to 2016-08-12 08:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:19:01 UTC to 2016-08-12 09:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:39:01 UTC to 2016-08-12 09:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 09:59:01 UTC to 2016-08-12 09:59:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 10:19:01 UTC to 2016-08-12 10:19:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-12 10:39:01 UTC to 2016-08-12 10:39:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:00:31 UTC to 2016-08-13 00:00:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:10:30 UTC to 2016-08-13 00:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:30:31 UTC to 2016-08-13 00:30:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 00:50:30 UTC to 2016-08-13 00:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:10:30 UTC to 2016-08-13 01:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:30:31 UTC to 2016-08-13 01:30:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 01:50:30 UTC to 2016-08-13 01:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:10:31 UTC to 2016-08-13 02:10:51 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:30:30 UTC to 2016-08-13 02:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 02:50:30 UTC to 2016-08-13 02:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:10:30 UTC to 2016-08-13 03:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:30:30 UTC to 2016-08-13 03:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 03:50:30 UTC to 2016-08-13 03:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:10:30 UTC to 2016-08-13 04:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:30:30 UTC to 2016-08-13 04:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 04:50:30 UTC to 2016-08-13 04:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:10:30 UTC to 2016-08-13 05:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:30:30 UTC to 2016-08-13 05:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 05:50:30 UTC to 2016-08-13 05:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:10:30 UTC to 2016-08-13 06:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:30:30 UTC to 2016-08-13 06:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 06:50:30 UTC to 2016-08-13 06:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:10:30 UTC to 2016-08-13 07:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:30:30 UTC to 2016-08-13 07:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 07:50:30 UTC to 2016-08-13 07:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:10:30 UTC to 2016-08-13 08:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:30:30 UTC to 2016-08-13 08:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 08:50:30 UTC to 2016-08-13 08:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:10:30 UTC to 2016-08-13 09:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:30:30 UTC to 2016-08-13 09:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 09:50:30 UTC to 2016-08-13 09:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:10:30 UTC to 2016-08-13 10:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:30:30 UTC to 2016-08-13 10:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 10:50:30 UTC to 2016-08-13 10:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:10:30 UTC to 2016-08-13 11:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:30:30 UTC to 2016-08-13 11:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 11:50:30 UTC to 2016-08-13 11:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:10:30 UTC to 2016-08-13 12:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:30:30 UTC to 2016-08-13 12:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 12:50:30 UTC to 2016-08-13 12:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:10:30 UTC to 2016-08-13 13:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:30:30 UTC to 2016-08-13 13:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 13:50:30 UTC to 2016-08-13 13:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:10:30 UTC to 2016-08-13 14:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:30:30 UTC to 2016-08-13 14:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 14:50:30 UTC to 2016-08-13 14:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:10:30 UTC to 2016-08-13 15:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:30:30 UTC to 2016-08-13 15:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 15:50:30 UTC to 2016-08-13 15:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:10:30 UTC to 2016-08-13 16:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:30:30 UTC to 2016-08-13 16:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 16:50:30 UTC to 2016-08-13 16:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:10:30 UTC to 2016-08-13 17:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:30:30 UTC to 2016-08-13 17:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 17:50:30 UTC to 2016-08-13 17:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:10:30 UTC to 2016-08-13 18:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:30:30 UTC to 2016-08-13 18:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 18:50:30 UTC to 2016-08-13 18:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:10:30 UTC to 2016-08-13 19:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:30:30 UTC to 2016-08-13 19:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 19:50:30 UTC to 2016-08-13 19:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:10:30 UTC to 2016-08-13 20:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:30:30 UTC to 2016-08-13 20:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 20:50:30 UTC to 2016-08-13 20:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:10:30 UTC to 2016-08-13 21:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:30:30 UTC to 2016-08-13 21:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 21:50:30 UTC to 2016-08-13 21:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:10:30 UTC to 2016-08-13 22:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:30:30 UTC to 2016-08-13 22:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 22:50:30 UTC to 2016-08-13 22:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:10:30 UTC to 2016-08-13 23:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:30:30 UTC to 2016-08-13 23:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-13 23:50:30 UTC to 2016-08-13 23:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:10:30 UTC to 2016-08-14 00:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:30:30 UTC to 2016-08-14 00:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 00:50:30 UTC to 2016-08-14 00:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:10:30 UTC to 2016-08-14 01:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:30:30 UTC to 2016-08-14 01:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 01:50:30 UTC to 2016-08-14 01:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:10:29 UTC to 2016-08-14 02:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:30:30 UTC to 2016-08-14 02:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 02:50:30 UTC to 2016-08-14 02:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:10:30 UTC to 2016-08-14 03:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:30:30 UTC to 2016-08-14 03:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 03:50:30 UTC to 2016-08-14 03:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:10:30 UTC to 2016-08-14 04:10:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:30:30 UTC to 2016-08-14 04:30:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 04:50:29 UTC to 2016-08-14 04:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:10:29 UTC to 2016-08-14 05:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:30:29 UTC to 2016-08-14 05:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 05:50:29 UTC to 2016-08-14 05:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:10:29 UTC to 2016-08-14 06:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:30:29 UTC to 2016-08-14 06:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 06:50:30 UTC to 2016-08-14 06:50:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:10:29 UTC to 2016-08-14 07:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:30:29 UTC to 2016-08-14 07:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 07:50:29 UTC to 2016-08-14 07:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:10:29 UTC to 2016-08-14 08:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:30:29 UTC to 2016-08-14 08:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 08:50:29 UTC to 2016-08-14 08:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:10:29 UTC to 2016-08-14 09:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:30:29 UTC to 2016-08-14 09:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 09:50:29 UTC to 2016-08-14 09:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:10:29 UTC to 2016-08-14 10:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:30:29 UTC to 2016-08-14 10:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 10:50:29 UTC to 2016-08-14 10:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:10:29 UTC to 2016-08-14 11:10:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:30:29 UTC to 2016-08-14 11:30:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-14 11:50:29 UTC to 2016-08-14 11:50:49 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 19:36:09 UTC to 2016-08-15 19:36:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 19:46:09 UTC to 2016-08-15 19:46:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:06:09 UTC to 2016-08-15 20:06:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:26:09 UTC to 2016-08-15 20:26:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 20:46:08 UTC to 2016-08-15 20:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:06:08 UTC to 2016-08-15 21:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:26:08 UTC to 2016-08-15 21:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 21:46:08 UTC to 2016-08-15 21:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:06:08 UTC to 2016-08-15 22:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:26:08 UTC to 2016-08-15 22:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 22:46:08 UTC to 2016-08-15 22:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:06:08 UTC to 2016-08-15 23:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:26:12 UTC to 2016-08-15 23:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-15 23:46:09 UTC to 2016-08-15 23:46:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:06:08 UTC to 2016-08-16 00:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:26:08 UTC to 2016-08-16 00:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 00:46:08 UTC to 2016-08-16 00:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:06:08 UTC to 2016-08-16 01:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:26:08 UTC to 2016-08-16 01:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 01:46:08 UTC to 2016-08-16 01:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:06:08 UTC to 2016-08-16 02:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:26:08 UTC to 2016-08-16 02:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 02:46:08 UTC to 2016-08-16 02:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:06:08 UTC to 2016-08-16 03:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:26:08 UTC to 2016-08-16 03:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 03:46:08 UTC to 2016-08-16 03:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:06:08 UTC to 2016-08-16 04:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:26:08 UTC to 2016-08-16 04:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 04:46:08 UTC to 2016-08-16 04:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:06:08 UTC to 2016-08-16 05:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:26:08 UTC to 2016-08-16 05:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 05:46:08 UTC to 2016-08-16 05:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:06:08 UTC to 2016-08-16 06:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:26:08 UTC to 2016-08-16 06:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 06:46:08 UTC to 2016-08-16 06:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:06:08 UTC to 2016-08-16 07:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:26:08 UTC to 2016-08-16 07:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 07:46:08 UTC to 2016-08-16 07:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:06:08 UTC to 2016-08-16 08:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:26:08 UTC to 2016-08-16 08:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 08:46:08 UTC to 2016-08-16 08:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:06:08 UTC to 2016-08-16 09:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:26:08 UTC to 2016-08-16 09:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 09:46:08 UTC to 2016-08-16 09:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:06:08 UTC to 2016-08-16 10:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:26:08 UTC to 2016-08-16 10:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 10:46:08 UTC to 2016-08-16 10:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:06:08 UTC to 2016-08-16 11:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:26:08 UTC to 2016-08-16 11:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 11:46:08 UTC to 2016-08-16 11:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:06:08 UTC to 2016-08-16 12:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:26:08 UTC to 2016-08-16 12:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 12:46:08 UTC to 2016-08-16 12:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:06:08 UTC to 2016-08-16 13:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:26:08 UTC to 2016-08-16 13:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 13:46:08 UTC to 2016-08-16 13:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:06:08 UTC to 2016-08-16 14:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:26:08 UTC to 2016-08-16 14:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 14:46:08 UTC to 2016-08-16 14:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:06:08 UTC to 2016-08-16 15:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:26:08 UTC to 2016-08-16 15:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 15:46:08 UTC to 2016-08-16 15:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:06:08 UTC to 2016-08-16 16:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:26:08 UTC to 2016-08-16 16:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 16:46:08 UTC to 2016-08-16 16:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:06:08 UTC to 2016-08-16 17:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:26:08 UTC to 2016-08-16 17:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 17:46:08 UTC to 2016-08-16 17:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:06:08 UTC to 2016-08-16 18:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:26:08 UTC to 2016-08-16 18:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 18:46:08 UTC to 2016-08-16 18:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:06:08 UTC to 2016-08-16 19:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:26:08 UTC to 2016-08-16 19:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 19:46:08 UTC to 2016-08-16 19:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:06:08 UTC to 2016-08-16 20:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:26:08 UTC to 2016-08-16 20:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 20:46:08 UTC to 2016-08-16 20:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:06:08 UTC to 2016-08-16 21:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:26:08 UTC to 2016-08-16 21:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 21:46:08 UTC to 2016-08-16 21:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:06:08 UTC to 2016-08-16 22:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:26:08 UTC to 2016-08-16 22:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 22:46:08 UTC to 2016-08-16 22:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:06:09 UTC to 2016-08-16 23:06:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:26:08 UTC to 2016-08-16 23:26:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-16 23:46:08 UTC to 2016-08-16 23:46:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:06:07 UTC to 2016-08-17 00:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:26:07 UTC to 2016-08-17 00:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 00:46:07 UTC to 2016-08-17 00:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:06:07 UTC to 2016-08-17 01:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:26:07 UTC to 2016-08-17 01:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 01:46:07 UTC to 2016-08-17 01:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:06:08 UTC to 2016-08-17 02:06:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:26:07 UTC to 2016-08-17 02:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 02:46:07 UTC to 2016-08-17 02:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:06:07 UTC to 2016-08-17 03:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:26:07 UTC to 2016-08-17 03:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 03:46:07 UTC to 2016-08-17 03:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:06:07 UTC to 2016-08-17 04:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:26:07 UTC to 2016-08-17 04:26:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 04:46:07 UTC to 2016-08-17 04:46:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 05:06:07 UTC to 2016-08-17 05:06:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 23:32:11 UTC to 2016-08-17 23:32:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-17 23:42:11 UTC to 2016-08-17 23:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:02:11 UTC to 2016-08-18 00:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:22:11 UTC to 2016-08-18 00:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 00:42:11 UTC to 2016-08-18 00:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:02:11 UTC to 2016-08-18 01:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:22:11 UTC to 2016-08-18 01:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 01:42:11 UTC to 2016-08-18 01:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:02:11 UTC to 2016-08-18 02:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:22:11 UTC to 2016-08-18 02:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 02:42:11 UTC to 2016-08-18 02:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:02:11 UTC to 2016-08-18 03:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:22:11 UTC to 2016-08-18 03:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 03:42:11 UTC to 2016-08-18 03:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:02:11 UTC to 2016-08-18 04:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:22:11 UTC to 2016-08-18 04:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 04:42:11 UTC to 2016-08-18 04:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:02:11 UTC to 2016-08-18 05:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:22:11 UTC to 2016-08-18 05:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 05:42:11 UTC to 2016-08-18 05:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:02:11 UTC to 2016-08-18 06:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:22:11 UTC to 2016-08-18 06:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 06:42:11 UTC to 2016-08-18 06:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:02:11 UTC to 2016-08-18 07:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:22:11 UTC to 2016-08-18 07:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 07:42:11 UTC to 2016-08-18 07:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:02:11 UTC to 2016-08-18 08:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:22:11 UTC to 2016-08-18 08:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 08:42:11 UTC to 2016-08-18 08:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:02:11 UTC to 2016-08-18 09:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:22:11 UTC to 2016-08-18 09:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 09:42:11 UTC to 2016-08-18 09:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:02:11 UTC to 2016-08-18 10:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:22:11 UTC to 2016-08-18 10:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 10:42:11 UTC to 2016-08-18 10:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:02:11 UTC to 2016-08-18 11:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:22:11 UTC to 2016-08-18 11:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 11:42:11 UTC to 2016-08-18 11:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:02:11 UTC to 2016-08-18 12:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:22:11 UTC to 2016-08-18 12:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 12:42:11 UTC to 2016-08-18 12:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:02:11 UTC to 2016-08-18 13:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:22:11 UTC to 2016-08-18 13:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 13:42:11 UTC to 2016-08-18 13:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:02:11 UTC to 2016-08-18 14:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:22:11 UTC to 2016-08-18 14:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 14:42:11 UTC to 2016-08-18 14:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:02:11 UTC to 2016-08-18 15:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:22:11 UTC to 2016-08-18 15:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 15:42:11 UTC to 2016-08-18 15:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:02:11 UTC to 2016-08-18 16:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:22:11 UTC to 2016-08-18 16:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 16:42:12 UTC to 2016-08-18 16:42:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:02:11 UTC to 2016-08-18 17:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:22:11 UTC to 2016-08-18 17:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 17:42:11 UTC to 2016-08-18 17:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 18:02:11 UTC to 2016-08-18 18:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 18:22:11 UTC to 2016-08-18 18:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:02:11 UTC to 2016-08-18 19:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:22:11 UTC to 2016-08-18 19:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 19:42:11 UTC to 2016-08-18 19:42:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:02:10 UTC to 2016-08-18 20:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:22:11 UTC to 2016-08-18 20:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 20:42:10 UTC to 2016-08-18 20:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:02:11 UTC to 2016-08-18 21:02:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:22:10 UTC to 2016-08-18 21:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 21:42:10 UTC to 2016-08-18 21:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:02:10 UTC to 2016-08-18 22:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:22:11 UTC to 2016-08-18 22:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 22:42:10 UTC to 2016-08-18 22:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:02:10 UTC to 2016-08-18 23:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:22:10 UTC to 2016-08-18 23:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-18 23:42:10 UTC to 2016-08-18 23:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:02:10 UTC to 2016-08-19 00:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:22:10 UTC to 2016-08-19 00:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 00:42:10 UTC to 2016-08-19 00:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:02:10 UTC to 2016-08-19 01:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:22:11 UTC to 2016-08-19 01:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 01:42:10 UTC to 2016-08-19 01:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:02:10 UTC to 2016-08-19 02:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:22:10 UTC to 2016-08-19 02:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 02:42:10 UTC to 2016-08-19 02:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:02:10 UTC to 2016-08-19 03:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:22:10 UTC to 2016-08-19 03:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 03:42:10 UTC to 2016-08-19 03:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:02:10 UTC to 2016-08-19 04:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:22:10 UTC to 2016-08-19 04:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 04:42:10 UTC to 2016-08-19 04:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:02:10 UTC to 2016-08-19 05:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:22:10 UTC to 2016-08-19 05:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 05:42:10 UTC to 2016-08-19 05:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:02:10 UTC to 2016-08-19 06:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:22:10 UTC to 2016-08-19 06:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 06:42:10 UTC to 2016-08-19 06:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:02:10 UTC to 2016-08-19 07:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:22:10 UTC to 2016-08-19 07:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 07:42:10 UTC to 2016-08-19 07:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:02:10 UTC to 2016-08-19 08:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:22:10 UTC to 2016-08-19 08:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 08:42:10 UTC to 2016-08-19 08:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:02:10 UTC to 2016-08-19 09:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:22:10 UTC to 2016-08-19 09:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 09:42:10 UTC to 2016-08-19 09:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:02:10 UTC to 2016-08-19 10:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:22:10 UTC to 2016-08-19 10:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 10:42:10 UTC to 2016-08-19 10:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:02:10 UTC to 2016-08-19 11:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:22:10 UTC to 2016-08-19 11:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 11:42:10 UTC to 2016-08-19 11:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:02:10 UTC to 2016-08-19 12:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:22:10 UTC to 2016-08-19 12:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 12:42:10 UTC to 2016-08-19 12:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:02:10 UTC to 2016-08-19 13:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:22:11 UTC to 2016-08-19 13:22:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 13:42:13 UTC to 2016-08-19 13:42:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:02:10 UTC to 2016-08-19 14:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:22:10 UTC to 2016-08-19 14:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 14:42:10 UTC to 2016-08-19 14:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:02:10 UTC to 2016-08-19 15:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:22:10 UTC to 2016-08-19 15:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 15:42:10 UTC to 2016-08-19 15:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:02:10 UTC to 2016-08-19 16:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:22:10 UTC to 2016-08-19 16:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 16:42:10 UTC to 2016-08-19 16:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:02:10 UTC to 2016-08-19 17:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:22:10 UTC to 2016-08-19 17:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 17:42:10 UTC to 2016-08-19 17:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:02:10 UTC to 2016-08-19 18:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:22:10 UTC to 2016-08-19 18:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 18:42:10 UTC to 2016-08-19 18:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:02:10 UTC to 2016-08-19 19:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:22:10 UTC to 2016-08-19 19:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 19:42:10 UTC to 2016-08-19 19:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:02:10 UTC to 2016-08-19 20:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:22:10 UTC to 2016-08-19 20:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 20:42:10 UTC to 2016-08-19 20:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:02:12 UTC to 2016-08-19 21:02:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:22:10 UTC to 2016-08-19 21:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 21:42:10 UTC to 2016-08-19 21:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:02:10 UTC to 2016-08-19 22:02:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:22:10 UTC to 2016-08-19 22:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 22:42:09 UTC to 2016-08-19 22:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:02:09 UTC to 2016-08-19 23:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:22:10 UTC to 2016-08-19 23:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-19 23:42:09 UTC to 2016-08-19 23:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:02:09 UTC to 2016-08-20 00:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:22:09 UTC to 2016-08-20 00:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 00:42:10 UTC to 2016-08-20 00:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:02:09 UTC to 2016-08-20 01:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:22:09 UTC to 2016-08-20 01:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 01:42:09 UTC to 2016-08-20 01:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:02:09 UTC to 2016-08-20 02:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:22:10 UTC to 2016-08-20 02:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 02:42:09 UTC to 2016-08-20 02:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:02:09 UTC to 2016-08-20 03:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:22:10 UTC to 2016-08-20 03:22:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 03:42:09 UTC to 2016-08-20 03:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:02:09 UTC to 2016-08-20 04:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:22:09 UTC to 2016-08-20 04:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 04:42:10 UTC to 2016-08-20 04:42:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:02:09 UTC to 2016-08-20 05:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:22:09 UTC to 2016-08-20 05:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 05:42:09 UTC to 2016-08-20 05:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:02:09 UTC to 2016-08-20 06:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:22:09 UTC to 2016-08-20 06:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 06:42:09 UTC to 2016-08-20 06:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:02:09 UTC to 2016-08-20 07:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:22:09 UTC to 2016-08-20 07:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 07:42:09 UTC to 2016-08-20 07:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:02:09 UTC to 2016-08-20 08:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:22:09 UTC to 2016-08-20 08:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 08:42:09 UTC to 2016-08-20 08:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:02:09 UTC to 2016-08-20 09:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:22:09 UTC to 2016-08-20 09:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 09:42:09 UTC to 2016-08-20 09:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:02:09 UTC to 2016-08-20 10:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:22:09 UTC to 2016-08-20 10:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 10:42:09 UTC to 2016-08-20 10:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:02:09 UTC to 2016-08-20 11:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:22:09 UTC to 2016-08-20 11:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 11:42:09 UTC to 2016-08-20 11:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:02:09 UTC to 2016-08-20 12:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:22:09 UTC to 2016-08-20 12:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 12:42:09 UTC to 2016-08-20 12:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:02:09 UTC to 2016-08-20 13:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:22:09 UTC to 2016-08-20 13:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 13:42:09 UTC to 2016-08-20 13:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:02:09 UTC to 2016-08-20 14:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:22:09 UTC to 2016-08-20 14:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 14:42:09 UTC to 2016-08-20 14:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:02:09 UTC to 2016-08-20 15:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:22:09 UTC to 2016-08-20 15:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 15:42:09 UTC to 2016-08-20 15:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:02:09 UTC to 2016-08-20 16:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:22:09 UTC to 2016-08-20 16:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 16:42:09 UTC to 2016-08-20 16:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:02:09 UTC to 2016-08-20 17:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:22:09 UTC to 2016-08-20 17:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 17:42:09 UTC to 2016-08-20 17:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:02:09 UTC to 2016-08-20 18:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:22:09 UTC to 2016-08-20 18:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 18:42:09 UTC to 2016-08-20 18:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:02:09 UTC to 2016-08-20 19:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:22:09 UTC to 2016-08-20 19:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 19:42:09 UTC to 2016-08-20 19:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:02:09 UTC to 2016-08-20 20:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:22:09 UTC to 2016-08-20 20:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 20:42:09 UTC to 2016-08-20 20:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:02:09 UTC to 2016-08-20 21:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:22:09 UTC to 2016-08-20 21:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 21:42:09 UTC to 2016-08-20 21:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:02:09 UTC to 2016-08-20 22:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:22:09 UTC to 2016-08-20 22:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 22:42:09 UTC to 2016-08-20 22:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:02:09 UTC to 2016-08-20 23:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:22:09 UTC to 2016-08-20 23:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-20 23:42:09 UTC to 2016-08-20 23:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:02:09 UTC to 2016-08-21 00:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:22:09 UTC to 2016-08-21 00:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 00:42:09 UTC to 2016-08-21 00:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:02:09 UTC to 2016-08-21 01:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:22:09 UTC to 2016-08-21 01:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 01:42:09 UTC to 2016-08-21 01:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:02:09 UTC to 2016-08-21 02:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:22:08 UTC to 2016-08-21 02:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 02:42:09 UTC to 2016-08-21 02:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:02:09 UTC to 2016-08-21 03:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:22:09 UTC to 2016-08-21 03:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 03:42:09 UTC to 2016-08-21 03:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:02:08 UTC to 2016-08-21 04:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:22:09 UTC to 2016-08-21 04:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 04:42:09 UTC to 2016-08-21 04:42:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:02:08 UTC to 2016-08-21 05:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:22:08 UTC to 2016-08-21 05:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 05:42:08 UTC to 2016-08-21 05:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:02:08 UTC to 2016-08-21 06:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:22:08 UTC to 2016-08-21 06:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 06:42:08 UTC to 2016-08-21 06:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:02:08 UTC to 2016-08-21 07:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:22:08 UTC to 2016-08-21 07:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 07:42:08 UTC to 2016-08-21 07:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:02:09 UTC to 2016-08-21 08:02:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:22:08 UTC to 2016-08-21 08:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 08:42:08 UTC to 2016-08-21 08:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:02:08 UTC to 2016-08-21 09:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:22:08 UTC to 2016-08-21 09:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 09:42:08 UTC to 2016-08-21 09:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:02:08 UTC to 2016-08-21 10:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:22:08 UTC to 2016-08-21 10:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 10:42:08 UTC to 2016-08-21 10:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:02:08 UTC to 2016-08-21 11:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:22:08 UTC to 2016-08-21 11:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 11:42:08 UTC to 2016-08-21 11:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:02:08 UTC to 2016-08-21 12:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:22:08 UTC to 2016-08-21 12:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 12:42:08 UTC to 2016-08-21 12:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:02:08 UTC to 2016-08-21 13:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:22:08 UTC to 2016-08-21 13:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 13:42:08 UTC to 2016-08-21 13:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:02:08 UTC to 2016-08-21 14:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:22:09 UTC to 2016-08-21 14:22:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 14:42:08 UTC to 2016-08-21 14:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:02:08 UTC to 2016-08-21 15:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:22:08 UTC to 2016-08-21 15:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 15:42:08 UTC to 2016-08-21 15:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:02:08 UTC to 2016-08-21 16:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:22:08 UTC to 2016-08-21 16:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 16:42:08 UTC to 2016-08-21 16:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:02:08 UTC to 2016-08-21 17:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:22:08 UTC to 2016-08-21 17:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 17:42:08 UTC to 2016-08-21 17:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:02:08 UTC to 2016-08-21 18:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:22:08 UTC to 2016-08-21 18:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 18:42:08 UTC to 2016-08-21 18:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:02:08 UTC to 2016-08-21 19:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:22:08 UTC to 2016-08-21 19:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 19:42:08 UTC to 2016-08-21 19:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:02:08 UTC to 2016-08-21 20:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:22:08 UTC to 2016-08-21 20:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 20:42:08 UTC to 2016-08-21 20:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:02:08 UTC to 2016-08-21 21:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:22:08 UTC to 2016-08-21 21:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 21:42:08 UTC to 2016-08-21 21:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:02:08 UTC to 2016-08-21 22:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:22:08 UTC to 2016-08-21 22:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 22:42:08 UTC to 2016-08-21 22:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:02:08 UTC to 2016-08-21 23:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:22:08 UTC to 2016-08-21 23:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-21 23:42:08 UTC to 2016-08-21 23:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:02:08 UTC to 2016-08-22 00:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:22:08 UTC to 2016-08-22 00:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 00:42:08 UTC to 2016-08-22 00:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:02:08 UTC to 2016-08-22 01:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:22:08 UTC to 2016-08-22 01:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 01:42:08 UTC to 2016-08-22 01:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:02:08 UTC to 2016-08-22 02:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:22:08 UTC to 2016-08-22 02:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 02:42:08 UTC to 2016-08-22 02:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:02:08 UTC to 2016-08-22 03:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:22:08 UTC to 2016-08-22 03:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 03:42:08 UTC to 2016-08-22 03:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:02:08 UTC to 2016-08-22 04:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:22:08 UTC to 2016-08-22 04:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 04:42:08 UTC to 2016-08-22 04:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:02:08 UTC to 2016-08-22 05:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:22:08 UTC to 2016-08-22 05:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 05:42:08 UTC to 2016-08-22 05:42:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:02:08 UTC to 2016-08-22 06:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:22:08 UTC to 2016-08-22 06:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 06:42:07 UTC to 2016-08-22 06:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:02:08 UTC to 2016-08-22 07:02:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:22:08 UTC to 2016-08-22 07:22:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 07:42:07 UTC to 2016-08-22 07:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:02:07 UTC to 2016-08-22 08:02:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:22:07 UTC to 2016-08-22 08:22:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 08:42:07 UTC to 2016-08-22 08:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:02:07 UTC to 2016-08-22 09:02:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:22:07 UTC to 2016-08-22 09:22:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-22 09:42:07 UTC to 2016-08-22 09:42:27 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:07:43 UTC to 2016-08-23 00:08:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:17:43 UTC to 2016-08-23 00:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:37:43 UTC to 2016-08-23 00:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 00:57:43 UTC to 2016-08-23 00:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:17:43 UTC to 2016-08-23 01:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:37:43 UTC to 2016-08-23 01:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 01:57:43 UTC to 2016-08-23 01:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:17:43 UTC to 2016-08-23 02:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:37:43 UTC to 2016-08-23 02:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 02:57:43 UTC to 2016-08-23 02:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:18:34 UTC to 2016-08-23 03:18:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:18:51 UTC to 2016-08-23 03:19:11 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:05 UTC to 2016-08-23 03:19:25 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:15 UTC to 2016-08-23 03:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:19:24 UTC to 2016-08-23 03:19:44 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:37:43 UTC to 2016-08-23 03:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 03:57:44 UTC to 2016-08-23 03:58:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:17:43 UTC to 2016-08-23 04:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:37:43 UTC to 2016-08-23 04:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 04:57:43 UTC to 2016-08-23 04:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:17:43 UTC to 2016-08-23 05:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:37:43 UTC to 2016-08-23 05:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 05:57:43 UTC to 2016-08-23 05:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:17:43 UTC to 2016-08-23 06:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:37:43 UTC to 2016-08-23 06:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 06:57:43 UTC to 2016-08-23 06:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:17:43 UTC to 2016-08-23 07:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:37:43 UTC to 2016-08-23 07:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 07:57:43 UTC to 2016-08-23 07:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:17:43 UTC to 2016-08-23 08:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:37:43 UTC to 2016-08-23 08:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 08:57:43 UTC to 2016-08-23 08:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:17:43 UTC to 2016-08-23 09:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:37:43 UTC to 2016-08-23 09:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 09:57:43 UTC to 2016-08-23 09:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:17:43 UTC to 2016-08-23 10:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:37:43 UTC to 2016-08-23 10:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 10:57:43 UTC to 2016-08-23 10:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:17:43 UTC to 2016-08-23 11:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:37:43 UTC to 2016-08-23 11:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 11:57:43 UTC to 2016-08-23 11:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:17:43 UTC to 2016-08-23 12:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:37:43 UTC to 2016-08-23 12:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 12:57:43 UTC to 2016-08-23 12:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:17:43 UTC to 2016-08-23 13:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:37:43 UTC to 2016-08-23 13:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 13:57:43 UTC to 2016-08-23 13:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:17:43 UTC to 2016-08-23 14:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:37:43 UTC to 2016-08-23 14:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 14:57:43 UTC to 2016-08-23 14:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:17:44 UTC to 2016-08-23 15:18:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:37:43 UTC to 2016-08-23 15:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 15:57:43 UTC to 2016-08-23 15:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:17:43 UTC to 2016-08-23 16:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:37:42 UTC to 2016-08-23 16:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 16:57:43 UTC to 2016-08-23 16:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:17:43 UTC to 2016-08-23 17:18:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:37:43 UTC to 2016-08-23 17:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 17:57:42 UTC to 2016-08-23 17:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:17:44 UTC to 2016-08-23 18:18:04 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:37:42 UTC to 2016-08-23 18:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 18:57:42 UTC to 2016-08-23 18:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:17:42 UTC to 2016-08-23 19:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:37:42 UTC to 2016-08-23 19:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 19:57:42 UTC to 2016-08-23 19:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:17:42 UTC to 2016-08-23 20:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:37:42 UTC to 2016-08-23 20:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 20:57:42 UTC to 2016-08-23 20:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:17:42 UTC to 2016-08-23 21:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:37:42 UTC to 2016-08-23 21:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 21:57:42 UTC to 2016-08-23 21:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:17:42 UTC to 2016-08-23 22:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:37:42 UTC to 2016-08-23 22:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 22:57:42 UTC to 2016-08-23 22:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:17:42 UTC to 2016-08-23 23:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:37:42 UTC to 2016-08-23 23:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-23 23:57:42 UTC to 2016-08-23 23:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:17:42 UTC to 2016-08-24 00:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:37:42 UTC to 2016-08-24 00:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 00:57:42 UTC to 2016-08-24 00:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:17:42 UTC to 2016-08-24 01:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:37:42 UTC to 2016-08-24 01:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 01:57:42 UTC to 2016-08-24 01:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:17:42 UTC to 2016-08-24 02:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:37:42 UTC to 2016-08-24 02:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 02:57:42 UTC to 2016-08-24 02:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:17:42 UTC to 2016-08-24 03:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:37:42 UTC to 2016-08-24 03:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 03:57:42 UTC to 2016-08-24 03:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:17:42 UTC to 2016-08-24 04:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:37:42 UTC to 2016-08-24 04:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 04:57:42 UTC to 2016-08-24 04:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:17:42 UTC to 2016-08-24 05:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:37:42 UTC to 2016-08-24 05:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 05:57:42 UTC to 2016-08-24 05:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:17:42 UTC to 2016-08-24 06:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:37:42 UTC to 2016-08-24 06:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 06:57:42 UTC to 2016-08-24 06:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:17:42 UTC to 2016-08-24 07:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:37:42 UTC to 2016-08-24 07:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 07:57:42 UTC to 2016-08-24 07:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:17:42 UTC to 2016-08-24 08:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:37:42 UTC to 2016-08-24 08:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 08:57:42 UTC to 2016-08-24 08:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:17:42 UTC to 2016-08-24 09:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:37:42 UTC to 2016-08-24 09:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 09:57:42 UTC to 2016-08-24 09:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:17:42 UTC to 2016-08-24 10:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:37:42 UTC to 2016-08-24 10:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 10:57:42 UTC to 2016-08-24 10:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:17:42 UTC to 2016-08-24 11:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:37:42 UTC to 2016-08-24 11:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 11:57:42 UTC to 2016-08-24 11:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:17:42 UTC to 2016-08-24 12:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:37:42 UTC to 2016-08-24 12:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 12:57:42 UTC to 2016-08-24 12:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:17:42 UTC to 2016-08-24 13:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:37:42 UTC to 2016-08-24 13:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 13:57:42 UTC to 2016-08-24 13:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:17:42 UTC to 2016-08-24 14:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:37:42 UTC to 2016-08-24 14:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 14:57:42 UTC to 2016-08-24 14:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:17:42 UTC to 2016-08-24 15:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:37:42 UTC to 2016-08-24 15:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 15:57:42 UTC to 2016-08-24 15:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:17:42 UTC to 2016-08-24 16:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:37:42 UTC to 2016-08-24 16:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 16:57:42 UTC to 2016-08-24 16:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:17:42 UTC to 2016-08-24 17:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:37:43 UTC to 2016-08-24 17:38:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 17:57:42 UTC to 2016-08-24 17:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:17:42 UTC to 2016-08-24 18:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:37:42 UTC to 2016-08-24 18:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 18:57:42 UTC to 2016-08-24 18:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:17:42 UTC to 2016-08-24 19:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:37:42 UTC to 2016-08-24 19:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 19:57:42 UTC to 2016-08-24 19:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:17:42 UTC to 2016-08-24 20:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:37:42 UTC to 2016-08-24 20:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 20:57:42 UTC to 2016-08-24 20:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:17:41 UTC to 2016-08-24 21:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:37:41 UTC to 2016-08-24 21:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 21:57:41 UTC to 2016-08-24 21:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:17:41 UTC to 2016-08-24 22:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:37:41 UTC to 2016-08-24 22:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 22:57:41 UTC to 2016-08-24 22:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:17:41 UTC to 2016-08-24 23:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:37:41 UTC to 2016-08-24 23:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-24 23:57:41 UTC to 2016-08-24 23:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:17:41 UTC to 2016-08-25 00:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:37:41 UTC to 2016-08-25 00:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 00:57:41 UTC to 2016-08-25 00:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:17:41 UTC to 2016-08-25 01:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:37:42 UTC to 2016-08-25 01:38:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 01:57:41 UTC to 2016-08-25 01:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:17:41 UTC to 2016-08-25 02:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:37:46 UTC to 2016-08-25 02:38:06 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 02:57:41 UTC to 2016-08-25 02:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:17:41 UTC to 2016-08-25 03:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:37:41 UTC to 2016-08-25 03:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 03:57:41 UTC to 2016-08-25 03:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:17:41 UTC to 2016-08-25 04:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:37:41 UTC to 2016-08-25 04:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 04:57:41 UTC to 2016-08-25 04:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:17:41 UTC to 2016-08-25 05:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:37:41 UTC to 2016-08-25 05:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 05:57:43 UTC to 2016-08-25 05:58:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:17:41 UTC to 2016-08-25 06:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:37:41 UTC to 2016-08-25 06:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 06:57:41 UTC to 2016-08-25 06:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:17:41 UTC to 2016-08-25 07:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:37:41 UTC to 2016-08-25 07:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 07:57:41 UTC to 2016-08-25 07:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:17:41 UTC to 2016-08-25 08:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:37:41 UTC to 2016-08-25 08:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 08:57:41 UTC to 2016-08-25 08:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:17:41 UTC to 2016-08-25 09:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:37:41 UTC to 2016-08-25 09:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 09:57:41 UTC to 2016-08-25 09:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:17:41 UTC to 2016-08-25 10:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:37:41 UTC to 2016-08-25 10:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 10:57:41 UTC to 2016-08-25 10:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:17:41 UTC to 2016-08-25 11:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:37:41 UTC to 2016-08-25 11:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 11:57:41 UTC to 2016-08-25 11:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:17:41 UTC to 2016-08-25 12:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:37:41 UTC to 2016-08-25 12:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 12:57:41 UTC to 2016-08-25 12:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:17:41 UTC to 2016-08-25 13:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:37:41 UTC to 2016-08-25 13:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 13:57:41 UTC to 2016-08-25 13:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:17:41 UTC to 2016-08-25 14:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:37:41 UTC to 2016-08-25 14:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 14:57:42 UTC to 2016-08-25 14:58:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:17:41 UTC to 2016-08-25 15:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:37:41 UTC to 2016-08-25 15:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 15:57:41 UTC to 2016-08-25 15:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:17:42 UTC to 2016-08-25 16:18:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:37:41 UTC to 2016-08-25 16:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 16:57:41 UTC to 2016-08-25 16:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:17:41 UTC to 2016-08-25 17:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:37:41 UTC to 2016-08-25 17:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 17:57:41 UTC to 2016-08-25 17:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:17:41 UTC to 2016-08-25 18:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:37:41 UTC to 2016-08-25 18:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 18:57:41 UTC to 2016-08-25 18:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:17:41 UTC to 2016-08-25 19:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:37:41 UTC to 2016-08-25 19:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 19:57:41 UTC to 2016-08-25 19:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:17:41 UTC to 2016-08-25 20:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:37:41 UTC to 2016-08-25 20:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 20:57:41 UTC to 2016-08-25 20:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:17:41 UTC to 2016-08-25 21:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:37:41 UTC to 2016-08-25 21:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 21:57:40 UTC to 2016-08-25 21:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:17:41 UTC to 2016-08-25 22:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:37:40 UTC to 2016-08-25 22:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 22:57:40 UTC to 2016-08-25 22:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:17:50 UTC to 2016-08-25 23:18:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:18:02 UTC to 2016-08-25 23:18:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:27:41 UTC to 2016-08-25 23:28:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:37:41 UTC to 2016-08-25 23:38:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-25 23:57:40 UTC to 2016-08-25 23:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:17:41 UTC to 2016-08-26 00:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:37:40 UTC to 2016-08-26 00:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 00:57:40 UTC to 2016-08-26 00:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:17:41 UTC to 2016-08-26 01:18:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:37:40 UTC to 2016-08-26 01:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 01:57:40 UTC to 2016-08-26 01:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:17:40 UTC to 2016-08-26 02:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:37:40 UTC to 2016-08-26 02:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 02:57:40 UTC to 2016-08-26 02:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:17:40 UTC to 2016-08-26 03:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:37:40 UTC to 2016-08-26 03:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 03:57:40 UTC to 2016-08-26 03:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:17:40 UTC to 2016-08-26 04:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:37:40 UTC to 2016-08-26 04:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 04:57:40 UTC to 2016-08-26 04:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:17:40 UTC to 2016-08-26 05:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:37:40 UTC to 2016-08-26 05:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 05:57:40 UTC to 2016-08-26 05:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:17:40 UTC to 2016-08-26 06:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:37:40 UTC to 2016-08-26 06:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 06:57:40 UTC to 2016-08-26 06:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:17:40 UTC to 2016-08-26 07:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:37:40 UTC to 2016-08-26 07:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 07:57:40 UTC to 2016-08-26 07:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:17:40 UTC to 2016-08-26 08:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:37:40 UTC to 2016-08-26 08:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 08:57:40 UTC to 2016-08-26 08:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:17:40 UTC to 2016-08-26 09:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:37:40 UTC to 2016-08-26 09:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 09:57:40 UTC to 2016-08-26 09:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:17:40 UTC to 2016-08-26 10:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:37:40 UTC to 2016-08-26 10:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 10:57:40 UTC to 2016-08-26 10:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:17:40 UTC to 2016-08-26 11:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:37:40 UTC to 2016-08-26 11:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 11:57:40 UTC to 2016-08-26 11:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:17:40 UTC to 2016-08-26 12:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:37:40 UTC to 2016-08-26 12:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 12:57:40 UTC to 2016-08-26 12:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:17:40 UTC to 2016-08-26 13:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:37:40 UTC to 2016-08-26 13:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 13:57:40 UTC to 2016-08-26 13:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:17:40 UTC to 2016-08-26 14:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:37:40 UTC to 2016-08-26 14:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 14:57:40 UTC to 2016-08-26 14:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:17:40 UTC to 2016-08-26 15:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:37:40 UTC to 2016-08-26 15:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 15:57:41 UTC to 2016-08-26 15:58:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:17:40 UTC to 2016-08-26 16:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:37:40 UTC to 2016-08-26 16:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 16:57:40 UTC to 2016-08-26 16:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:17:40 UTC to 2016-08-26 17:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:37:40 UTC to 2016-08-26 17:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 17:57:40 UTC to 2016-08-26 17:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:17:40 UTC to 2016-08-26 18:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:37:40 UTC to 2016-08-26 18:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 18:57:40 UTC to 2016-08-26 18:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:17:40 UTC to 2016-08-26 19:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:37:40 UTC to 2016-08-26 19:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 19:57:40 UTC to 2016-08-26 19:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:17:40 UTC to 2016-08-26 20:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:37:40 UTC to 2016-08-26 20:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 20:57:40 UTC to 2016-08-26 20:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:17:40 UTC to 2016-08-26 21:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:37:40 UTC to 2016-08-26 21:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 21:57:40 UTC to 2016-08-26 21:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:17:40 UTC to 2016-08-26 22:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:37:40 UTC to 2016-08-26 22:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 22:57:40 UTC to 2016-08-26 22:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:17:40 UTC to 2016-08-26 23:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:37:40 UTC to 2016-08-26 23:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-26 23:57:40 UTC to 2016-08-26 23:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:17:40 UTC to 2016-08-27 00:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:37:40 UTC to 2016-08-27 00:38:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 00:57:40 UTC to 2016-08-27 00:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:17:40 UTC to 2016-08-27 01:18:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:37:39 UTC to 2016-08-27 01:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 01:57:40 UTC to 2016-08-27 01:58:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:17:39 UTC to 2016-08-27 02:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:37:39 UTC to 2016-08-27 02:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 02:57:39 UTC to 2016-08-27 02:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:17:39 UTC to 2016-08-27 03:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:37:39 UTC to 2016-08-27 03:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 03:57:39 UTC to 2016-08-27 03:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:17:39 UTC to 2016-08-27 04:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:37:39 UTC to 2016-08-27 04:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 04:57:39 UTC to 2016-08-27 04:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:17:39 UTC to 2016-08-27 05:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:37:39 UTC to 2016-08-27 05:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 05:57:39 UTC to 2016-08-27 05:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:17:39 UTC to 2016-08-27 06:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:37:39 UTC to 2016-08-27 06:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 06:57:39 UTC to 2016-08-27 06:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:17:39 UTC to 2016-08-27 07:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:37:39 UTC to 2016-08-27 07:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 07:57:39 UTC to 2016-08-27 07:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:17:39 UTC to 2016-08-27 08:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:37:39 UTC to 2016-08-27 08:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 08:57:39 UTC to 2016-08-27 08:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:17:39 UTC to 2016-08-27 09:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:37:39 UTC to 2016-08-27 09:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 09:57:39 UTC to 2016-08-27 09:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:17:39 UTC to 2016-08-27 10:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:37:39 UTC to 2016-08-27 10:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 10:57:39 UTC to 2016-08-27 10:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:17:39 UTC to 2016-08-27 11:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:37:39 UTC to 2016-08-27 11:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 11:57:39 UTC to 2016-08-27 11:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:17:39 UTC to 2016-08-27 12:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:37:39 UTC to 2016-08-27 12:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 12:57:39 UTC to 2016-08-27 12:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:17:39 UTC to 2016-08-27 13:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:37:39 UTC to 2016-08-27 13:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 13:57:39 UTC to 2016-08-27 13:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:17:39 UTC to 2016-08-27 14:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:37:39 UTC to 2016-08-27 14:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 14:57:39 UTC to 2016-08-27 14:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:17:39 UTC to 2016-08-27 15:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:37:39 UTC to 2016-08-27 15:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 15:57:39 UTC to 2016-08-27 15:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:17:39 UTC to 2016-08-27 16:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:37:39 UTC to 2016-08-27 16:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 16:57:39 UTC to 2016-08-27 16:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:17:39 UTC to 2016-08-27 17:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:37:39 UTC to 2016-08-27 17:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 17:57:39 UTC to 2016-08-27 17:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:17:39 UTC to 2016-08-27 18:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:37:39 UTC to 2016-08-27 18:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 18:57:39 UTC to 2016-08-27 18:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:17:39 UTC to 2016-08-27 19:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:37:39 UTC to 2016-08-27 19:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 19:57:39 UTC to 2016-08-27 19:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:17:39 UTC to 2016-08-27 20:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:37:39 UTC to 2016-08-27 20:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 20:57:39 UTC to 2016-08-27 20:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:17:39 UTC to 2016-08-27 21:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:37:39 UTC to 2016-08-27 21:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 21:57:39 UTC to 2016-08-27 21:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:17:39 UTC to 2016-08-27 22:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:37:39 UTC to 2016-08-27 22:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 22:57:39 UTC to 2016-08-27 22:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:17:39 UTC to 2016-08-27 23:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:37:39 UTC to 2016-08-27 23:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-27 23:57:39 UTC to 2016-08-27 23:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:17:39 UTC to 2016-08-28 00:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:37:39 UTC to 2016-08-28 00:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 00:57:39 UTC to 2016-08-28 00:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:17:39 UTC to 2016-08-28 01:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:37:39 UTC to 2016-08-28 01:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 01:57:39 UTC to 2016-08-28 01:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:17:39 UTC to 2016-08-28 02:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:37:39 UTC to 2016-08-28 02:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 02:57:39 UTC to 2016-08-28 02:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:17:39 UTC to 2016-08-28 03:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:37:39 UTC to 2016-08-28 03:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 03:57:39 UTC to 2016-08-28 03:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:17:39 UTC to 2016-08-28 04:17:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:37:39 UTC to 2016-08-28 04:37:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-28 04:57:39 UTC to 2016-08-28 04:57:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:12:03 UTC to 2016-08-29 01:12:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:22:03 UTC to 2016-08-29 01:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 01:42:03 UTC to 2016-08-29 01:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:02:03 UTC to 2016-08-29 02:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:22:03 UTC to 2016-08-29 02:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 02:42:03 UTC to 2016-08-29 02:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:02:03 UTC to 2016-08-29 03:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:22:03 UTC to 2016-08-29 03:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 03:42:03 UTC to 2016-08-29 03:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:02:03 UTC to 2016-08-29 04:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:22:03 UTC to 2016-08-29 04:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 04:42:03 UTC to 2016-08-29 04:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:02:03 UTC to 2016-08-29 05:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:22:03 UTC to 2016-08-29 05:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 05:42:03 UTC to 2016-08-29 05:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:02:03 UTC to 2016-08-29 06:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:22:03 UTC to 2016-08-29 06:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 06:42:03 UTC to 2016-08-29 06:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:02:03 UTC to 2016-08-29 07:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:22:03 UTC to 2016-08-29 07:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 07:42:03 UTC to 2016-08-29 07:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:02:03 UTC to 2016-08-29 08:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:22:03 UTC to 2016-08-29 08:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 08:42:03 UTC to 2016-08-29 08:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:02:03 UTC to 2016-08-29 09:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:22:03 UTC to 2016-08-29 09:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 09:42:03 UTC to 2016-08-29 09:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:02:03 UTC to 2016-08-29 10:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:22:03 UTC to 2016-08-29 10:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 10:42:03 UTC to 2016-08-29 10:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:02:03 UTC to 2016-08-29 11:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:22:03 UTC to 2016-08-29 11:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 11:42:03 UTC to 2016-08-29 11:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:02:03 UTC to 2016-08-29 12:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:22:03 UTC to 2016-08-29 12:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 12:42:03 UTC to 2016-08-29 12:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:02:03 UTC to 2016-08-29 13:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:22:03 UTC to 2016-08-29 13:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 13:42:03 UTC to 2016-08-29 13:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:02:03 UTC to 2016-08-29 14:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:22:03 UTC to 2016-08-29 14:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 14:42:03 UTC to 2016-08-29 14:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:02:03 UTC to 2016-08-29 15:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:22:03 UTC to 2016-08-29 15:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 15:42:03 UTC to 2016-08-29 15:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:02:03 UTC to 2016-08-29 16:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:22:03 UTC to 2016-08-29 16:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 16:42:03 UTC to 2016-08-29 16:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:02:03 UTC to 2016-08-29 17:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:22:03 UTC to 2016-08-29 17:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 17:42:03 UTC to 2016-08-29 17:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:02:03 UTC to 2016-08-29 18:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:22:03 UTC to 2016-08-29 18:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 18:42:03 UTC to 2016-08-29 18:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:02:03 UTC to 2016-08-29 19:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:22:03 UTC to 2016-08-29 19:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 19:42:03 UTC to 2016-08-29 19:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:02:03 UTC to 2016-08-29 20:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:22:03 UTC to 2016-08-29 20:22:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 20:42:03 UTC to 2016-08-29 20:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:02:03 UTC to 2016-08-29 21:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:22:02 UTC to 2016-08-29 21:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 21:42:03 UTC to 2016-08-29 21:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:02:03 UTC to 2016-08-29 22:02:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:22:02 UTC to 2016-08-29 22:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 22:42:02 UTC to 2016-08-29 22:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:02:02 UTC to 2016-08-29 23:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:22:02 UTC to 2016-08-29 23:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-29 23:42:03 UTC to 2016-08-29 23:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:02:02 UTC to 2016-08-30 00:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:22:02 UTC to 2016-08-30 00:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 00:42:03 UTC to 2016-08-30 00:42:23 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:02:02 UTC to 2016-08-30 01:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:22:02 UTC to 2016-08-30 01:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 01:42:02 UTC to 2016-08-30 01:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:02:02 UTC to 2016-08-30 02:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:22:02 UTC to 2016-08-30 02:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 02:42:02 UTC to 2016-08-30 02:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:02:02 UTC to 2016-08-30 03:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:22:02 UTC to 2016-08-30 03:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 03:42:02 UTC to 2016-08-30 03:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:02:02 UTC to 2016-08-30 04:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:22:02 UTC to 2016-08-30 04:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 04:42:02 UTC to 2016-08-30 04:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:02:02 UTC to 2016-08-30 05:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:22:02 UTC to 2016-08-30 05:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 05:42:02 UTC to 2016-08-30 05:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:02:02 UTC to 2016-08-30 06:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:22:02 UTC to 2016-08-30 06:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 06:42:02 UTC to 2016-08-30 06:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:02:02 UTC to 2016-08-30 07:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:22:02 UTC to 2016-08-30 07:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 07:42:02 UTC to 2016-08-30 07:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:02:02 UTC to 2016-08-30 08:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:22:02 UTC to 2016-08-30 08:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 08:42:02 UTC to 2016-08-30 08:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:02:02 UTC to 2016-08-30 09:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:22:02 UTC to 2016-08-30 09:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 09:42:02 UTC to 2016-08-30 09:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:02:02 UTC to 2016-08-30 10:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:22:02 UTC to 2016-08-30 10:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 10:42:02 UTC to 2016-08-30 10:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:02:02 UTC to 2016-08-30 11:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:22:02 UTC to 2016-08-30 11:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 11:42:02 UTC to 2016-08-30 11:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:02:02 UTC to 2016-08-30 12:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:22:02 UTC to 2016-08-30 12:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 12:42:02 UTC to 2016-08-30 12:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:02:02 UTC to 2016-08-30 13:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:22:02 UTC to 2016-08-30 13:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 13:42:02 UTC to 2016-08-30 13:42:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 14:02:02 UTC to 2016-08-30 14:02:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-30 14:22:02 UTC to 2016-08-30 14:22:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:01:16 UTC to 2016-08-31 00:01:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:21:16 UTC to 2016-08-31 00:21:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 00:41:15 UTC to 2016-08-31 00:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:01:16 UTC to 2016-08-31 01:01:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:21:15 UTC to 2016-08-31 01:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 01:41:16 UTC to 2016-08-31 01:41:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:01:15 UTC to 2016-08-31 02:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:21:15 UTC to 2016-08-31 02:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 02:41:15 UTC to 2016-08-31 02:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:01:15 UTC to 2016-08-31 03:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:21:15 UTC to 2016-08-31 03:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 03:41:15 UTC to 2016-08-31 03:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:01:15 UTC to 2016-08-31 04:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:21:15 UTC to 2016-08-31 04:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 04:41:15 UTC to 2016-08-31 04:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:01:15 UTC to 2016-08-31 05:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:21:15 UTC to 2016-08-31 05:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 05:41:15 UTC to 2016-08-31 05:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:01:15 UTC to 2016-08-31 06:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:21:15 UTC to 2016-08-31 06:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 06:41:15 UTC to 2016-08-31 06:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:01:15 UTC to 2016-08-31 07:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:21:15 UTC to 2016-08-31 07:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 07:41:15 UTC to 2016-08-31 07:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:01:15 UTC to 2016-08-31 08:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:21:15 UTC to 2016-08-31 08:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 08:41:15 UTC to 2016-08-31 08:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:01:15 UTC to 2016-08-31 09:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:21:15 UTC to 2016-08-31 09:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 09:41:15 UTC to 2016-08-31 09:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:01:15 UTC to 2016-08-31 10:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:21:15 UTC to 2016-08-31 10:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 10:41:15 UTC to 2016-08-31 10:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:01:15 UTC to 2016-08-31 11:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:21:15 UTC to 2016-08-31 11:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 11:41:15 UTC to 2016-08-31 11:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:01:15 UTC to 2016-08-31 12:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:21:15 UTC to 2016-08-31 12:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 12:41:15 UTC to 2016-08-31 12:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:01:15 UTC to 2016-08-31 13:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:21:15 UTC to 2016-08-31 13:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 13:41:15 UTC to 2016-08-31 13:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:01:15 UTC to 2016-08-31 14:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:21:15 UTC to 2016-08-31 14:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 14:41:15 UTC to 2016-08-31 14:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:01:15 UTC to 2016-08-31 15:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:21:15 UTC to 2016-08-31 15:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 15:41:15 UTC to 2016-08-31 15:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:01:15 UTC to 2016-08-31 16:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:21:15 UTC to 2016-08-31 16:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 16:41:15 UTC to 2016-08-31 16:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:01:15 UTC to 2016-08-31 17:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:21:15 UTC to 2016-08-31 17:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 17:41:15 UTC to 2016-08-31 17:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:01:15 UTC to 2016-08-31 18:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:21:15 UTC to 2016-08-31 18:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 18:41:15 UTC to 2016-08-31 18:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:01:15 UTC to 2016-08-31 19:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:21:15 UTC to 2016-08-31 19:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 19:41:15 UTC to 2016-08-31 19:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:01:15 UTC to 2016-08-31 20:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:21:15 UTC to 2016-08-31 20:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 20:41:15 UTC to 2016-08-31 20:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:01:15 UTC to 2016-08-31 21:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:21:15 UTC to 2016-08-31 21:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 21:41:15 UTC to 2016-08-31 21:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:01:15 UTC to 2016-08-31 22:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:21:15 UTC to 2016-08-31 22:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 22:41:15 UTC to 2016-08-31 22:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:01:15 UTC to 2016-08-31 23:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:21:15 UTC to 2016-08-31 23:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-08-31 23:41:15 UTC to 2016-08-31 23:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:01:15 UTC to 2016-09-01 00:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:21:15 UTC to 2016-09-01 00:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 00:41:15 UTC to 2016-09-01 00:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:01:15 UTC to 2016-09-01 01:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:21:15 UTC to 2016-09-01 01:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 01:41:15 UTC to 2016-09-01 01:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:01:15 UTC to 2016-09-01 02:01:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:21:15 UTC to 2016-09-01 02:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 02:41:15 UTC to 2016-09-01 02:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:01:14 UTC to 2016-09-01 03:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:21:14 UTC to 2016-09-01 03:21:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 03:41:15 UTC to 2016-09-01 03:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:01:14 UTC to 2016-09-01 04:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:21:15 UTC to 2016-09-01 04:21:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 04:41:15 UTC to 2016-09-01 04:41:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 05:01:14 UTC to 2016-09-01 05:01:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-01 05:21:14 UTC to 2016-09-01 05:21:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-09-02 22:09:16 UTC to 2016-09-02 22:09:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:19:16 UTC to 2016-09-02 22:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:39:16 UTC to 2016-09-02 22:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:59:16 UTC to 2016-09-02 22:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:19:16 UTC to 2016-09-02 23:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:39:16 UTC to 2016-09-02 23:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:59:16 UTC to 2016-09-02 23:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:19:16 UTC to 2016-09-03 00:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:39:16 UTC to 2016-09-03 00:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:59:16 UTC to 2016-09-03 00:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:19:16 UTC to 2016-09-03 01:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:39:16 UTC to 2016-09-03 01:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:59:16 UTC to 2016-09-03 01:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:19:16 UTC to 2016-09-03 02:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:39:16 UTC to 2016-09-03 02:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:59:16 UTC to 2016-09-03 02:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:19:16 UTC to 2016-09-03 03:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:39:16 UTC to 2016-09-03 03:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:59:16 UTC to 2016-09-03 03:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:19:16 UTC to 2016-09-03 04:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:39:16 UTC to 2016-09-03 04:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:59:16 UTC to 2016-09-03 04:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:19:16 UTC to 2016-09-03 05:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:39:16 UTC to 2016-09-03 05:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:59:16 UTC to 2016-09-03 05:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:19:16 UTC to 2016-09-03 06:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:39:15 UTC to 2016-09-03 06:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:59:15 UTC to 2016-09-03 06:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:19:15 UTC to 2016-09-03 07:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:39:15 UTC to 2016-09-03 07:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:59:16 UTC to 2016-09-03 07:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:19:15 UTC to 2016-09-03 08:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:39:15 UTC to 2016-09-03 08:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:59:15 UTC to 2016-09-03 08:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:19:15 UTC to 2016-09-03 09:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:39:15 UTC to 2016-09-03 09:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:59:15 UTC to 2016-09-03 09:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:19:15 UTC to 2016-09-03 10:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:39:15 UTC to 2016-09-03 10:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:59:15 UTC to 2016-09-03 10:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:19:15 UTC to 2016-09-03 11:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:39:15 UTC to 2016-09-03 11:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:59:15 UTC to 2016-09-03 11:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:19:15 UTC to 2016-09-03 12:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:39:15 UTC to 2016-09-03 12:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:59:15 UTC to 2016-09-03 12:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:19:15 UTC to 2016-09-03 13:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:39:15 UTC to 2016-09-03 13:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:59:15 UTC to 2016-09-03 13:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:19:15 UTC to 2016-09-03 14:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:39:15 UTC to 2016-09-03 14:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:59:15 UTC to 2016-09-03 14:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:19:15 UTC to 2016-09-03 15:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:39:15 UTC to 2016-09-03 15:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:59:15 UTC to 2016-09-03 15:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:19:15 UTC to 2016-09-03 16:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:39:15 UTC to 2016-09-03 16:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:59:15 UTC to 2016-09-03 16:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:19:15 UTC to 2016-09-03 17:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:39:15 UTC to 2016-09-03 17:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:59:15 UTC to 2016-09-03 17:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:19:15 UTC to 2016-09-03 18:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:39:15 UTC to 2016-09-03 18:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:59:15 UTC to 2016-09-03 18:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:19:15 UTC to 2016-09-03 19:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:39:15 UTC to 2016-09-03 19:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:59:15 UTC to 2016-09-03 19:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:19:15 UTC to 2016-09-03 20:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:39:15 UTC to 2016-09-03 20:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:59:15 UTC to 2016-09-03 20:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:19:15 UTC to 2016-09-03 21:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:39:15 UTC to 2016-09-03 21:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:59:15 UTC to 2016-09-03 21:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:19:15 UTC to 2016-09-03 22:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:39:15 UTC to 2016-09-03 22:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:59:15 UTC to 2016-09-03 22:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:19:15 UTC to 2016-09-03 23:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:39:15 UTC to 2016-09-03 23:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:59:15 UTC to 2016-09-03 23:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:19:15 UTC to 2016-09-04 00:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:39:15 UTC to 2016-09-04 00:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:59:15 UTC to 2016-09-04 00:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:19:15 UTC to 2016-09-04 01:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:39:15 UTC to 2016-09-04 01:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:59:15 UTC to 2016-09-04 01:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:19:15 UTC to 2016-09-04 02:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:39:15 UTC to 2016-09-04 02:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:59:15 UTC to 2016-09-04 02:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:19:15 UTC to 2016-09-04 03:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:39:15 UTC to 2016-09-04 03:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:59:15 UTC to 2016-09-04 03:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:19:15 UTC to 2016-09-04 04:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:39:15 UTC to 2016-09-04 04:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:59:15 UTC to 2016-09-04 04:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:19:15 UTC to 2016-09-04 05:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:39:15 UTC to 2016-09-04 05:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:59:15 UTC to 2016-09-04 05:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:19:15 UTC to 2016-09-04 06:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:39:15 UTC to 2016-09-04 06:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:59:15 UTC to 2016-09-04 06:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:19:15 UTC to 2016-09-04 07:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:39:15 UTC to 2016-09-04 07:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:59:15 UTC to 2016-09-04 07:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:19:14 UTC to 2016-09-04 08:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:39:14 UTC to 2016-09-04 08:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:59:15 UTC to 2016-09-04 08:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:19:15 UTC to 2016-09-04 09:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:39:14 UTC to 2016-09-04 09:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:59:15 UTC to 2016-09-04 09:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:19:14 UTC to 2016-09-04 10:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:39:14 UTC to 2016-09-04 10:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:59:14 UTC to 2016-09-04 10:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:19:15 UTC to 2016-09-04 11:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:39:14 UTC to 2016-09-04 11:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:59:14 UTC to 2016-09-04 11:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:19:14 UTC to 2016-09-04 12:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:39:14 UTC to 2016-09-04 12:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:59:14 UTC to 2016-09-04 12:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 13:19:14 UTC to 2016-09-04 13:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 23:22:35 UTC to 2016-09-04 23:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 23:42:35 UTC to 2016-09-04 23:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:02:35 UTC to 2016-09-05 00:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:22:35 UTC to 2016-09-05 00:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:42:35 UTC to 2016-09-05 00:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:02:35 UTC to 2016-09-05 01:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:22:35 UTC to 2016-09-05 01:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:42:35 UTC to 2016-09-05 01:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:02:35 UTC to 2016-09-05 02:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:22:35 UTC to 2016-09-05 02:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:42:35 UTC to 2016-09-05 02:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:02:35 UTC to 2016-09-05 03:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:22:35 UTC to 2016-09-05 03:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:42:35 UTC to 2016-09-05 03:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:02:35 UTC to 2016-09-05 04:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:22:35 UTC to 2016-09-05 04:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:42:35 UTC to 2016-09-05 04:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:02:35 UTC to 2016-09-05 05:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:22:35 UTC to 2016-09-05 05:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:42:35 UTC to 2016-09-05 05:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:02:35 UTC to 2016-09-05 06:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:22:35 UTC to 2016-09-05 06:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:42:35 UTC to 2016-09-05 06:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:02:35 UTC to 2016-09-05 07:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:22:35 UTC to 2016-09-05 07:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:42:35 UTC to 2016-09-05 07:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:02:35 UTC to 2016-09-05 08:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:22:35 UTC to 2016-09-05 08:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:42:35 UTC to 2016-09-05 08:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:02:35 UTC to 2016-09-05 09:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:22:35 UTC to 2016-09-05 09:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:42:35 UTC to 2016-09-05 09:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:02:35 UTC to 2016-09-05 10:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:22:35 UTC to 2016-09-05 10:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:42:35 UTC to 2016-09-05 10:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:02:35 UTC to 2016-09-05 11:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:22:34 UTC to 2016-09-05 11:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:42:35 UTC to 2016-09-05 11:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:02:34 UTC to 2016-09-05 12:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:22:34 UTC to 2016-09-05 12:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:42:34 UTC to 2016-09-05 12:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:02:34 UTC to 2016-09-05 13:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:22:34 UTC to 2016-09-05 13:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:42:34 UTC to 2016-09-05 13:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:02:34 UTC to 2016-09-05 14:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:22:34 UTC to 2016-09-05 14:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:42:34 UTC to 2016-09-05 14:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:02:34 UTC to 2016-09-05 15:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:22:34 UTC to 2016-09-05 15:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:42:34 UTC to 2016-09-05 15:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:02:34 UTC to 2016-09-05 16:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:22:34 UTC to 2016-09-05 16:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:42:34 UTC to 2016-09-05 16:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:02:34 UTC to 2016-09-05 17:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:22:34 UTC to 2016-09-05 17:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:42:34 UTC to 2016-09-05 17:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:02:34 UTC to 2016-09-05 18:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:22:34 UTC to 2016-09-05 18:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:42:34 UTC to 2016-09-05 18:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:02:34 UTC to 2016-09-05 19:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:22:34 UTC to 2016-09-05 19:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:42:34 UTC to 2016-09-05 19:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:02:34 UTC to 2016-09-05 20:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:22:34 UTC to 2016-09-05 20:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:42:34 UTC to 2016-09-05 20:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:02:34 UTC to 2016-09-05 21:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:22:34 UTC to 2016-09-05 21:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:42:34 UTC to 2016-09-05 21:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:02:34 UTC to 2016-09-05 22:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:22:34 UTC to 2016-09-05 22:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:42:34 UTC to 2016-09-05 22:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:02:34 UTC to 2016-09-05 23:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:22:34 UTC to 2016-09-05 23:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:42:34 UTC to 2016-09-05 23:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:02:34 UTC to 2016-09-06 00:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:22:34 UTC to 2016-09-06 00:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:42:34 UTC to 2016-09-06 00:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:02:34 UTC to 2016-09-06 01:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:22:34 UTC to 2016-09-06 01:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:42:34 UTC to 2016-09-06 01:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:02:34 UTC to 2016-09-06 02:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:22:34 UTC to 2016-09-06 02:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:42:34 UTC to 2016-09-06 02:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:02:34 UTC to 2016-09-06 03:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:22:34 UTC to 2016-09-06 03:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:42:34 UTC to 2016-09-06 03:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:02:34 UTC to 2016-09-06 04:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:22:34 UTC to 2016-09-06 04:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:42:34 UTC to 2016-09-06 04:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:02:34 UTC to 2016-09-06 05:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:22:34 UTC to 2016-09-06 05:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:42:34 UTC to 2016-09-06 05:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:02:34 UTC to 2016-09-06 06:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:22:34 UTC to 2016-09-06 06:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:42:34 UTC to 2016-09-06 06:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:02:34 UTC to 2016-09-06 07:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:22:34 UTC to 2016-09-06 07:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:42:34 UTC to 2016-09-06 07:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:02:34 UTC to 2016-09-06 08:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:22:34 UTC to 2016-09-06 08:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:42:34 UTC to 2016-09-06 08:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:02:34 UTC to 2016-09-06 09:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:22:34 UTC to 2016-09-06 09:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:42:34 UTC to 2016-09-06 09:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:02:34 UTC to 2016-09-06 10:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:22:34 UTC to 2016-09-06 10:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:42:34 UTC to 2016-09-06 10:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 11:02:34 UTC to 2016-09-06 11:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 11:22:34 UTC to 2016-09-06 11:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:17:02 UTC to 2016-09-07 16:17:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:27:02 UTC to 2016-09-07 16:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:47:02 UTC to 2016-09-07 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:07:02 UTC to 2016-09-07 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:27:02 UTC to 2016-09-07 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:47:02 UTC to 2016-09-07 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:07:11 UTC to 2016-09-07 18:07:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:27:02 UTC to 2016-09-07 18:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:47:02 UTC to 2016-09-07 18:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:07:02 UTC to 2016-09-07 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:27:02 UTC to 2016-09-07 19:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:47:02 UTC to 2016-09-07 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:07:02 UTC to 2016-09-07 20:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:27:02 UTC to 2016-09-07 20:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:47:02 UTC to 2016-09-07 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:07:02 UTC to 2016-09-07 21:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:27:02 UTC to 2016-09-07 21:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:47:02 UTC to 2016-09-07 21:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:07:02 UTC to 2016-09-07 22:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:27:02 UTC to 2016-09-07 22:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:47:02 UTC to 2016-09-07 22:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:07:02 UTC to 2016-09-07 23:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:27:02 UTC to 2016-09-07 23:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:47:02 UTC to 2016-09-07 23:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:07:02 UTC to 2016-09-08 00:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:27:02 UTC to 2016-09-08 00:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:47:02 UTC to 2016-09-08 00:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:07:02 UTC to 2016-09-08 01:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:27:02 UTC to 2016-09-08 01:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:47:02 UTC to 2016-09-08 01:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:07:02 UTC to 2016-09-08 02:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:27:02 UTC to 2016-09-08 02:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:47:02 UTC to 2016-09-08 02:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:07:02 UTC to 2016-09-08 03:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:27:02 UTC to 2016-09-08 03:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:47:02 UTC to 2016-09-08 03:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:07:02 UTC to 2016-09-08 04:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:27:02 UTC to 2016-09-08 04:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:47:02 UTC to 2016-09-08 04:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:07:02 UTC to 2016-09-08 05:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:27:02 UTC to 2016-09-08 05:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:47:02 UTC to 2016-09-08 05:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:07:01 UTC to 2016-09-08 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:27:02 UTC to 2016-09-08 06:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:47:02 UTC to 2016-09-08 06:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:07:01 UTC to 2016-09-08 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:27:01 UTC to 2016-09-08 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:47:01 UTC to 2016-09-08 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:07:01 UTC to 2016-09-08 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:27:01 UTC to 2016-09-08 08:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:47:01 UTC to 2016-09-08 08:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:07:01 UTC to 2016-09-08 09:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:27:01 UTC to 2016-09-08 09:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:47:01 UTC to 2016-09-08 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:07:01 UTC to 2016-09-08 10:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:27:01 UTC to 2016-09-08 10:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:47:01 UTC to 2016-09-08 10:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:07:01 UTC to 2016-09-08 11:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:27:01 UTC to 2016-09-08 11:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:47:01 UTC to 2016-09-08 11:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:07:01 UTC to 2016-09-08 12:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:27:01 UTC to 2016-09-08 12:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:47:01 UTC to 2016-09-08 12:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:07:01 UTC to 2016-09-08 13:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:27:01 UTC to 2016-09-08 13:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:47:01 UTC to 2016-09-08 13:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:07:01 UTC to 2016-09-08 14:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:27:01 UTC to 2016-09-08 14:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:47:01 UTC to 2016-09-08 14:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:07:01 UTC to 2016-09-08 15:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:27:01 UTC to 2016-09-08 15:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:47:01 UTC to 2016-09-08 15:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:07:01 UTC to 2016-09-08 16:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:27:01 UTC to 2016-09-08 16:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:47:01 UTC to 2016-09-08 16:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:07:01 UTC to 2016-09-08 17:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:27:01 UTC to 2016-09-08 17:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:47:01 UTC to 2016-09-08 17:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:07:01 UTC to 2016-09-08 18:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:27:01 UTC to 2016-09-08 18:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:47:01 UTC to 2016-09-08 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:07:01 UTC to 2016-09-08 19:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:27:01 UTC to 2016-09-08 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:47:01 UTC to 2016-09-08 19:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:07:01 UTC to 2016-09-08 20:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:27:01 UTC to 2016-09-08 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:47:01 UTC to 2016-09-08 20:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:07:01 UTC to 2016-09-08 21:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:27:01 UTC to 2016-09-08 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:47:01 UTC to 2016-09-08 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:07:01 UTC to 2016-09-08 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:27:01 UTC to 2016-09-08 22:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:47:01 UTC to 2016-09-08 22:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:07:01 UTC to 2016-09-08 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:27:01 UTC to 2016-09-08 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:47:01 UTC to 2016-09-08 23:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:07:01 UTC to 2016-09-09 00:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:27:01 UTC to 2016-09-09 00:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:47:01 UTC to 2016-09-09 00:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:07:01 UTC to 2016-09-09 01:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:27:01 UTC to 2016-09-09 01:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:47:01 UTC to 2016-09-09 01:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:07:01 UTC to 2016-09-09 02:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:27:01 UTC to 2016-09-09 02:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:47:01 UTC to 2016-09-09 02:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:07:01 UTC to 2016-09-09 03:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:27:01 UTC to 2016-09-09 03:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:47:01 UTC to 2016-09-09 03:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:07:01 UTC to 2016-09-09 04:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:27:01 UTC to 2016-09-09 04:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:47:01 UTC to 2016-09-09 04:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:07:01 UTC to 2016-09-09 05:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:27:01 UTC to 2016-09-09 05:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:47:01 UTC to 2016-09-09 05:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:07:01 UTC to 2016-09-09 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:27:01 UTC to 2016-09-09 06:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:47:01 UTC to 2016-09-09 06:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:07:01 UTC to 2016-09-09 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:27:01 UTC to 2016-09-09 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:47:01 UTC to 2016-09-09 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:07:01 UTC to 2016-09-09 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:27:00 UTC to 2016-09-09 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:47:00 UTC to 2016-09-09 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:07:00 UTC to 2016-09-09 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:27:00 UTC to 2016-09-09 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:47:01 UTC to 2016-09-09 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:07:00 UTC to 2016-09-09 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:27:00 UTC to 2016-09-09 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:47:00 UTC to 2016-09-09 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:07:00 UTC to 2016-09-09 11:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:27:00 UTC to 2016-09-09 11:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:47:00 UTC to 2016-09-09 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:07:00 UTC to 2016-09-09 12:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:27:00 UTC to 2016-09-09 12:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:47:00 UTC to 2016-09-09 12:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:07:00 UTC to 2016-09-09 13:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:27:00 UTC to 2016-09-09 13:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:47:00 UTC to 2016-09-09 13:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:07:00 UTC to 2016-09-09 14:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:27:00 UTC to 2016-09-09 14:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:47:00 UTC to 2016-09-09 14:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:07:00 UTC to 2016-09-09 15:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:27:00 UTC to 2016-09-09 15:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:47:00 UTC to 2016-09-09 15:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:07:00 UTC to 2016-09-09 16:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:27:00 UTC to 2016-09-09 16:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:47:00 UTC to 2016-09-09 16:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:07:00 UTC to 2016-09-09 17:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:27:00 UTC to 2016-09-09 17:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:47:00 UTC to 2016-09-09 17:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:07:00 UTC to 2016-09-09 18:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:27:00 UTC to 2016-09-09 18:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:47:00 UTC to 2016-09-09 18:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:07:00 UTC to 2016-09-09 19:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:27:00 UTC to 2016-09-09 19:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:47:00 UTC to 2016-09-09 19:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:07:00 UTC to 2016-09-09 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:27:00 UTC to 2016-09-09 20:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:47:00 UTC to 2016-09-09 20:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:07:00 UTC to 2016-09-09 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:27:00 UTC to 2016-09-09 21:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:47:00 UTC to 2016-09-09 21:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:07:00 UTC to 2016-09-09 22:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:27:00 UTC to 2016-09-09 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:47:00 UTC to 2016-09-09 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:07:00 UTC to 2016-09-09 23:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:27:00 UTC to 2016-09-09 23:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:47:00 UTC to 2016-09-09 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:07:00 UTC to 2016-09-10 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:27:00 UTC to 2016-09-10 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:47:00 UTC to 2016-09-10 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:07:00 UTC to 2016-09-10 01:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:27:00 UTC to 2016-09-10 01:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:47:00 UTC to 2016-09-10 01:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:07:00 UTC to 2016-09-10 02:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:27:00 UTC to 2016-09-10 02:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:47:00 UTC to 2016-09-10 02:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:07:00 UTC to 2016-09-10 03:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:27:00 UTC to 2016-09-10 03:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:47:00 UTC to 2016-09-10 03:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:07:00 UTC to 2016-09-10 04:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:27:00 UTC to 2016-09-10 04:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:47:00 UTC to 2016-09-10 04:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:07:00 UTC to 2016-09-10 05:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:27:00 UTC to 2016-09-10 05:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:47:00 UTC to 2016-09-10 05:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:07:00 UTC to 2016-09-10 06:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:27:00 UTC to 2016-09-10 06:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:47:00 UTC to 2016-09-10 06:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:07:00 UTC to 2016-09-10 07:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:27:00 UTC to 2016-09-10 07:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:47:00 UTC to 2016-09-10 07:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:07:00 UTC to 2016-09-10 08:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:27:00 UTC to 2016-09-10 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:47:00 UTC to 2016-09-10 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:07:00 UTC to 2016-09-10 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:27:00 UTC to 2016-09-10 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:47:00 UTC to 2016-09-10 09:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:07:00 UTC to 2016-09-10 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:27:00 UTC to 2016-09-10 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:47:00 UTC to 2016-09-10 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:06:59 UTC to 2016-09-10 11:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:26:59 UTC to 2016-09-10 11:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:47:00 UTC to 2016-09-10 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:06:59 UTC to 2016-09-10 12:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:26:59 UTC to 2016-09-10 12:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:46:59 UTC to 2016-09-10 12:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:06:59 UTC to 2016-09-10 13:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:26:59 UTC to 2016-09-10 13:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:46:59 UTC to 2016-09-10 13:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:06:59 UTC to 2016-09-10 14:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:26:59 UTC to 2016-09-10 14:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:46:59 UTC to 2016-09-10 14:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:06:59 UTC to 2016-09-10 15:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:26:59 UTC to 2016-09-10 15:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:46:59 UTC to 2016-09-10 15:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:06:59 UTC to 2016-09-10 16:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:26:59 UTC to 2016-09-10 16:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:46:59 UTC to 2016-09-10 16:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:06:59 UTC to 2016-09-10 17:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:26:59 UTC to 2016-09-10 17:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:46:59 UTC to 2016-09-10 17:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:06:59 UTC to 2016-09-10 18:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:26:59 UTC to 2016-09-10 18:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:46:59 UTC to 2016-09-10 18:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:06:59 UTC to 2016-09-10 19:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:26:59 UTC to 2016-09-10 19:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:46:59 UTC to 2016-09-10 19:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:06:59 UTC to 2016-09-10 20:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:26:59 UTC to 2016-09-10 20:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:46:59 UTC to 2016-09-10 20:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:06:59 UTC to 2016-09-10 21:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:26:59 UTC to 2016-09-10 21:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:46:59 UTC to 2016-09-10 21:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:06:59 UTC to 2016-09-10 22:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:26:59 UTC to 2016-09-10 22:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:46:59 UTC to 2016-09-10 22:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:06:59 UTC to 2016-09-10 23:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:26:59 UTC to 2016-09-10 23:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:46:59 UTC to 2016-09-10 23:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:06:59 UTC to 2016-09-11 00:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:26:59 UTC to 2016-09-11 00:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:46:59 UTC to 2016-09-11 00:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:06:59 UTC to 2016-09-11 01:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:26:59 UTC to 2016-09-11 01:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:46:59 UTC to 2016-09-11 01:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:06:59 UTC to 2016-09-11 02:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:26:59 UTC to 2016-09-11 02:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:46:59 UTC to 2016-09-11 02:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:06:59 UTC to 2016-09-11 03:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:26:59 UTC to 2016-09-11 03:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:46:59 UTC to 2016-09-11 03:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:06:59 UTC to 2016-09-11 04:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:26:59 UTC to 2016-09-11 04:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:46:59 UTC to 2016-09-11 04:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:06:59 UTC to 2016-09-11 05:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:26:59 UTC to 2016-09-11 05:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:46:59 UTC to 2016-09-11 05:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:06:59 UTC to 2016-09-11 06:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:26:59 UTC to 2016-09-11 06:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:46:59 UTC to 2016-09-11 06:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:06:59 UTC to 2016-09-11 07:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:26:59 UTC to 2016-09-11 07:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:46:59 UTC to 2016-09-11 07:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:06:59 UTC to 2016-09-11 08:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:26:59 UTC to 2016-09-11 08:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:46:59 UTC to 2016-09-11 08:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 09:06:59 UTC to 2016-09-11 09:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 09:26:59 UTC to 2016-09-11 09:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:03:42 UTC to 2016-09-11 23:04:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:13:42 UTC to 2016-09-11 23:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:33:42 UTC to 2016-09-11 23:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:53:42 UTC to 2016-09-11 23:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:13:42 UTC to 2016-09-12 00:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:33:42 UTC to 2016-09-12 00:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:53:42 UTC to 2016-09-12 00:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:13:42 UTC to 2016-09-12 01:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:33:42 UTC to 2016-09-12 01:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:53:42 UTC to 2016-09-12 01:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:13:42 UTC to 2016-09-12 02:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:33:42 UTC to 2016-09-12 02:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:53:42 UTC to 2016-09-12 02:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:13:42 UTC to 2016-09-12 03:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:33:42 UTC to 2016-09-12 03:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:53:42 UTC to 2016-09-12 03:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:13:42 UTC to 2016-09-12 04:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:33:42 UTC to 2016-09-12 04:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:53:42 UTC to 2016-09-12 04:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:13:42 UTC to 2016-09-12 05:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:33:42 UTC to 2016-09-12 05:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:53:42 UTC to 2016-09-12 05:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:13:42 UTC to 2016-09-12 06:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:33:42 UTC to 2016-09-12 06:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:53:42 UTC to 2016-09-12 06:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:13:42 UTC to 2016-09-12 07:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:33:42 UTC to 2016-09-12 07:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:53:42 UTC to 2016-09-12 07:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:13:42 UTC to 2016-09-12 08:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:33:42 UTC to 2016-09-12 08:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:53:42 UTC to 2016-09-12 08:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:13:42 UTC to 2016-09-12 09:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:33:42 UTC to 2016-09-12 09:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:53:42 UTC to 2016-09-12 09:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:13:42 UTC to 2016-09-12 10:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:33:42 UTC to 2016-09-12 10:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:53:42 UTC to 2016-09-12 10:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:13:42 UTC to 2016-09-12 11:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:33:42 UTC to 2016-09-12 11:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:53:42 UTC to 2016-09-12 11:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:13:42 UTC to 2016-09-12 12:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:33:42 UTC to 2016-09-12 12:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:53:42 UTC to 2016-09-12 12:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:13:42 UTC to 2016-09-12 13:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:33:42 UTC to 2016-09-12 13:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:53:45 UTC to 2016-09-12 13:54:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:13:42 UTC to 2016-09-12 14:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:33:42 UTC to 2016-09-12 14:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:53:42 UTC to 2016-09-12 14:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:13:42 UTC to 2016-09-12 15:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:33:42 UTC to 2016-09-12 15:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:53:42 UTC to 2016-09-12 15:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:13:42 UTC to 2016-09-12 16:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:33:42 UTC to 2016-09-12 16:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:53:42 UTC to 2016-09-12 16:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:13:42 UTC to 2016-09-12 17:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:33:42 UTC to 2016-09-12 17:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:53:42 UTC to 2016-09-12 17:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:13:42 UTC to 2016-09-12 18:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:33:42 UTC to 2016-09-12 18:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:53:42 UTC to 2016-09-12 18:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:13:42 UTC to 2016-09-12 19:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:33:42 UTC to 2016-09-12 19:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:53:42 UTC to 2016-09-12 19:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:13:42 UTC to 2016-09-12 20:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:33:42 UTC to 2016-09-12 20:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:53:42 UTC to 2016-09-12 20:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:13:42 UTC to 2016-09-12 21:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:33:42 UTC to 2016-09-12 21:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:53:43 UTC to 2016-09-12 21:54:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:13:42 UTC to 2016-09-12 22:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:33:42 UTC to 2016-09-12 22:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:53:42 UTC to 2016-09-12 22:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:13:42 UTC to 2016-09-12 23:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:33:42 UTC to 2016-09-12 23:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:53:42 UTC to 2016-09-12 23:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:13:42 UTC to 2016-09-13 00:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:33:42 UTC to 2016-09-13 00:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:53:42 UTC to 2016-09-13 00:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:13:41 UTC to 2016-09-13 01:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:33:41 UTC to 2016-09-13 01:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:53:41 UTC to 2016-09-13 01:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:13:41 UTC to 2016-09-13 02:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:33:41 UTC to 2016-09-13 02:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:53:41 UTC to 2016-09-13 02:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:13:41 UTC to 2016-09-13 03:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:33:41 UTC to 2016-09-13 03:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:53:41 UTC to 2016-09-13 03:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:13:41 UTC to 2016-09-13 04:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:33:41 UTC to 2016-09-13 04:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:53:41 UTC to 2016-09-13 04:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:13:41 UTC to 2016-09-13 05:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:33:41 UTC to 2016-09-13 05:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:53:41 UTC to 2016-09-13 05:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:13:41 UTC to 2016-09-13 06:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:33:41 UTC to 2016-09-13 06:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:53:41 UTC to 2016-09-13 06:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:13:41 UTC to 2016-09-13 07:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:33:41 UTC to 2016-09-13 07:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:53:41 UTC to 2016-09-13 07:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:13:41 UTC to 2016-09-13 08:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:33:41 UTC to 2016-09-13 08:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:53:41 UTC to 2016-09-13 08:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:13:41 UTC to 2016-09-13 09:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:33:41 UTC to 2016-09-13 09:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:53:41 UTC to 2016-09-13 09:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:13:41 UTC to 2016-09-13 10:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:33:41 UTC to 2016-09-13 10:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:53:41 UTC to 2016-09-13 10:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:13:41 UTC to 2016-09-13 11:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:33:41 UTC to 2016-09-13 11:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:53:41 UTC to 2016-09-13 11:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:13:41 UTC to 2016-09-13 12:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:33:41 UTC to 2016-09-13 12:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:53:41 UTC to 2016-09-13 12:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:13:41 UTC to 2016-09-13 13:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:33:41 UTC to 2016-09-13 13:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:53:41 UTC to 2016-09-13 13:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:13:41 UTC to 2016-09-13 14:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:33:41 UTC to 2016-09-13 14:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:53:41 UTC to 2016-09-13 14:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:13:41 UTC to 2016-09-13 15:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:33:41 UTC to 2016-09-13 15:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:53:41 UTC to 2016-09-13 15:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:13:41 UTC to 2016-09-13 16:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:33:41 UTC to 2016-09-13 16:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:53:41 UTC to 2016-09-13 16:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:13:41 UTC to 2016-09-13 17:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:33:41 UTC to 2016-09-13 17:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:53:41 UTC to 2016-09-13 17:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:13:41 UTC to 2016-09-13 18:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:33:41 UTC to 2016-09-13 18:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:53:41 UTC to 2016-09-13 18:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:13:41 UTC to 2016-09-13 19:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:33:41 UTC to 2016-09-13 19:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:53:41 UTC to 2016-09-13 19:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:13:41 UTC to 2016-09-13 20:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:33:41 UTC to 2016-09-13 20:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:53:41 UTC to 2016-09-13 20:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:13:41 UTC to 2016-09-13 21:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:33:41 UTC to 2016-09-13 21:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:53:41 UTC to 2016-09-13 21:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:13:41 UTC to 2016-09-13 22:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:33:41 UTC to 2016-09-13 22:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:53:41 UTC to 2016-09-13 22:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:13:41 UTC to 2016-09-13 23:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:33:41 UTC to 2016-09-13 23:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:53:41 UTC to 2016-09-13 23:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:13:41 UTC to 2016-09-14 00:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:33:41 UTC to 2016-09-14 00:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:53:41 UTC to 2016-09-14 00:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:13:41 UTC to 2016-09-14 01:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:33:41 UTC to 2016-09-14 01:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:53:41 UTC to 2016-09-14 01:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:13:41 UTC to 2016-09-14 02:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:33:41 UTC to 2016-09-14 02:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:53:40 UTC to 2016-09-14 02:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:13:40 UTC to 2016-09-14 03:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:33:40 UTC to 2016-09-14 03:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:53:40 UTC to 2016-09-14 03:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:13:40 UTC to 2016-09-14 04:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:33:40 UTC to 2016-09-14 04:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:53:40 UTC to 2016-09-14 04:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:13:40 UTC to 2016-09-14 05:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:33:40 UTC to 2016-09-14 05:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:53:40 UTC to 2016-09-14 05:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:13:40 UTC to 2016-09-14 06:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:33:40 UTC to 2016-09-14 06:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:53:40 UTC to 2016-09-14 06:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:13:40 UTC to 2016-09-14 07:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:33:40 UTC to 2016-09-14 07:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:53:40 UTC to 2016-09-14 07:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:13:40 UTC to 2016-09-14 08:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:33:40 UTC to 2016-09-14 08:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:53:40 UTC to 2016-09-14 08:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:13:40 UTC to 2016-09-14 09:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:33:40 UTC to 2016-09-14 09:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:53:40 UTC to 2016-09-14 09:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:13:47 UTC to 2016-09-14 10:14:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:33:40 UTC to 2016-09-14 10:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:53:40 UTC to 2016-09-14 10:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:13:40 UTC to 2016-09-14 11:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:33:40 UTC to 2016-09-14 11:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:53:40 UTC to 2016-09-14 11:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:13:40 UTC to 2016-09-14 12:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:33:40 UTC to 2016-09-14 12:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:53:40 UTC to 2016-09-14 12:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:13:40 UTC to 2016-09-14 13:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:33:40 UTC to 2016-09-14 13:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:53:40 UTC to 2016-09-14 13:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:13:40 UTC to 2016-09-14 14:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:33:40 UTC to 2016-09-14 14:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:53:40 UTC to 2016-09-14 14:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:13:40 UTC to 2016-09-14 15:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:33:40 UTC to 2016-09-14 15:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:53:40 UTC to 2016-09-14 15:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:13:40 UTC to 2016-09-14 16:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:33:40 UTC to 2016-09-14 16:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:53:40 UTC to 2016-09-14 16:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:13:40 UTC to 2016-09-14 17:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:33:40 UTC to 2016-09-14 17:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:53:40 UTC to 2016-09-14 17:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:13:40 UTC to 2016-09-14 18:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:33:40 UTC to 2016-09-14 18:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:53:40 UTC to 2016-09-14 18:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:13:40 UTC to 2016-09-14 19:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:33:40 UTC to 2016-09-14 19:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:53:40 UTC to 2016-09-14 19:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:13:40 UTC to 2016-09-14 20:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:33:40 UTC to 2016-09-14 20:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:53:40 UTC to 2016-09-14 20:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:13:40 UTC to 2016-09-14 21:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:33:40 UTC to 2016-09-14 21:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:53:40 UTC to 2016-09-14 21:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:13:40 UTC to 2016-09-14 22:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:33:40 UTC to 2016-09-14 22:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:53:40 UTC to 2016-09-14 22:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:13:40 UTC to 2016-09-14 23:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:33:40 UTC to 2016-09-14 23:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:53:40 UTC to 2016-09-14 23:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:13:40 UTC to 2016-09-15 00:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:33:40 UTC to 2016-09-15 00:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:53:40 UTC to 2016-09-15 00:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:13:40 UTC to 2016-09-15 01:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:33:40 UTC to 2016-09-15 01:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:53:40 UTC to 2016-09-15 01:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:13:40 UTC to 2016-09-15 02:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:33:40 UTC to 2016-09-15 02:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:53:40 UTC to 2016-09-15 02:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:13:40 UTC to 2016-09-15 03:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:33:40 UTC to 2016-09-15 03:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:53:40 UTC to 2016-09-15 03:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:13:40 UTC to 2016-09-15 04:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:33:40 UTC to 2016-09-15 04:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:53:40 UTC to 2016-09-15 04:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:13:40 UTC to 2016-09-15 05:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:33:39 UTC to 2016-09-15 05:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:53:40 UTC to 2016-09-15 05:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:13:40 UTC to 2016-09-15 06:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:33:40 UTC to 2016-09-15 06:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:53:40 UTC to 2016-09-15 06:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:13:40 UTC to 2016-09-15 07:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:33:39 UTC to 2016-09-15 07:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:53:39 UTC to 2016-09-15 07:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:13:39 UTC to 2016-09-15 08:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:33:39 UTC to 2016-09-15 08:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:53:39 UTC to 2016-09-15 08:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:13:39 UTC to 2016-09-15 09:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:33:39 UTC to 2016-09-15 09:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:53:39 UTC to 2016-09-15 09:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:13:39 UTC to 2016-09-15 10:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:33:39 UTC to 2016-09-15 10:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:53:39 UTC to 2016-09-15 10:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:13:39 UTC to 2016-09-15 11:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:33:39 UTC to 2016-09-15 11:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:53:39 UTC to 2016-09-15 11:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:13:39 UTC to 2016-09-15 12:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:33:39 UTC to 2016-09-15 12:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:53:39 UTC to 2016-09-15 12:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:13:39 UTC to 2016-09-15 13:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:33:39 UTC to 2016-09-15 13:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:53:39 UTC to 2016-09-15 13:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:13:39 UTC to 2016-09-15 14:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:33:39 UTC to 2016-09-15 14:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:53:39 UTC to 2016-09-15 14:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:13:39 UTC to 2016-09-15 15:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:33:39 UTC to 2016-09-15 15:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:53:39 UTC to 2016-09-15 15:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:13:39 UTC to 2016-09-15 16:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:33:39 UTC to 2016-09-15 16:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:53:39 UTC to 2016-09-15 16:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:13:39 UTC to 2016-09-15 17:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:33:39 UTC to 2016-09-15 17:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:53:39 UTC to 2016-09-15 17:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:13:39 UTC to 2016-09-15 18:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:33:39 UTC to 2016-09-15 18:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:53:39 UTC to 2016-09-15 18:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:13:39 UTC to 2016-09-15 19:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:33:39 UTC to 2016-09-15 19:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:53:39 UTC to 2016-09-15 19:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:13:39 UTC to 2016-09-15 20:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:33:39 UTC to 2016-09-15 20:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:53:39 UTC to 2016-09-15 20:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:13:39 UTC to 2016-09-15 21:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:33:39 UTC to 2016-09-15 21:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:53:39 UTC to 2016-09-15 21:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:13:39 UTC to 2016-09-15 22:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:33:39 UTC to 2016-09-15 22:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:53:39 UTC to 2016-09-15 22:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:13:39 UTC to 2016-09-15 23:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:33:39 UTC to 2016-09-15 23:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:53:39 UTC to 2016-09-15 23:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:13:39 UTC to 2016-09-16 00:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:33:39 UTC to 2016-09-16 00:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:53:39 UTC to 2016-09-16 00:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:13:39 UTC to 2016-09-16 01:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:33:39 UTC to 2016-09-16 01:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:53:39 UTC to 2016-09-16 01:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:13:39 UTC to 2016-09-16 02:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:33:39 UTC to 2016-09-16 02:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:53:39 UTC to 2016-09-16 02:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:13:39 UTC to 2016-09-16 03:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:33:39 UTC to 2016-09-16 03:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:53:39 UTC to 2016-09-16 03:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:13:39 UTC to 2016-09-16 04:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:33:39 UTC to 2016-09-16 04:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:53:39 UTC to 2016-09-16 04:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:13:39 UTC to 2016-09-16 05:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:33:39 UTC to 2016-09-16 05:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:53:39 UTC to 2016-09-16 05:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:13:39 UTC to 2016-09-16 06:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:33:39 UTC to 2016-09-16 06:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:53:39 UTC to 2016-09-16 06:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:13:39 UTC to 2016-09-16 07:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:33:39 UTC to 2016-09-16 07:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:53:39 UTC to 2016-09-16 07:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:13:39 UTC to 2016-09-16 08:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:33:39 UTC to 2016-09-16 08:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:53:39 UTC to 2016-09-16 08:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:13:39 UTC to 2016-09-16 09:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:33:38 UTC to 2016-09-16 09:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:53:39 UTC to 2016-09-16 09:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:13:38 UTC to 2016-09-16 10:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:33:38 UTC to 2016-09-16 10:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:53:38 UTC to 2016-09-16 10:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:13:38 UTC to 2016-09-16 11:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:33:38 UTC to 2016-09-16 11:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:53:38 UTC to 2016-09-16 11:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:13:38 UTC to 2016-09-16 12:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:33:38 UTC to 2016-09-16 12:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:53:38 UTC to 2016-09-16 12:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 19:55:13 UTC to 2016-09-18 19:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:15:13 UTC to 2016-09-18 20:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:35:13 UTC to 2016-09-18 20:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:55:13 UTC to 2016-09-18 20:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:15:13 UTC to 2016-09-18 21:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:35:13 UTC to 2016-09-18 21:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:55:13 UTC to 2016-09-18 21:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:15:13 UTC to 2016-09-18 22:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:35:13 UTC to 2016-09-18 22:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:55:13 UTC to 2016-09-18 22:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:15:13 UTC to 2016-09-18 23:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:35:13 UTC to 2016-09-18 23:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:55:13 UTC to 2016-09-18 23:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:15:13 UTC to 2016-09-19 00:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:35:13 UTC to 2016-09-19 00:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:55:13 UTC to 2016-09-19 00:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:15:13 UTC to 2016-09-19 01:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:35:13 UTC to 2016-09-19 01:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:55:13 UTC to 2016-09-19 01:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:15:13 UTC to 2016-09-19 02:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:35:13 UTC to 2016-09-19 02:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:55:13 UTC to 2016-09-19 02:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:15:13 UTC to 2016-09-19 03:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:35:13 UTC to 2016-09-19 03:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:55:13 UTC to 2016-09-19 03:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:15:13 UTC to 2016-09-19 04:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:35:13 UTC to 2016-09-19 04:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:55:13 UTC to 2016-09-19 04:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:15:13 UTC to 2016-09-19 05:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:35:13 UTC to 2016-09-19 05:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:55:13 UTC to 2016-09-19 05:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:15:13 UTC to 2016-09-19 06:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:35:13 UTC to 2016-09-19 06:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:55:13 UTC to 2016-09-19 06:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:15:13 UTC to 2016-09-19 07:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:35:13 UTC to 2016-09-19 07:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:55:13 UTC to 2016-09-19 07:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:15:13 UTC to 2016-09-19 08:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:35:13 UTC to 2016-09-19 08:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:55:12 UTC to 2016-09-19 08:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:15:13 UTC to 2016-09-19 09:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:35:12 UTC to 2016-09-19 09:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:55:12 UTC to 2016-09-19 09:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:15:13 UTC to 2016-09-19 10:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:35:12 UTC to 2016-09-19 10:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:55:12 UTC to 2016-09-19 10:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:15:12 UTC to 2016-09-19 11:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:35:12 UTC to 2016-09-19 11:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:55:30 UTC to 2016-09-19 11:55:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:15:30 UTC to 2016-09-19 12:15:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:37:25 UTC to 2016-09-19 12:37:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:59:09 UTC to 2016-09-19 12:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:20:42 UTC to 2016-09-19 13:21:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:45:52 UTC to 2016-09-19 13:46:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:58:06 UTC to 2016-09-19 13:58:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:15:12 UTC to 2016-09-19 14:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:35:12 UTC to 2016-09-19 14:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:55:12 UTC to 2016-09-19 14:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:15:12 UTC to 2016-09-19 15:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:35:12 UTC to 2016-09-19 15:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:55:12 UTC to 2016-09-19 15:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:15:12 UTC to 2016-09-19 16:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:35:12 UTC to 2016-09-19 16:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:55:12 UTC to 2016-09-19 16:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:15:12 UTC to 2016-09-19 17:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:35:12 UTC to 2016-09-19 17:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:55:12 UTC to 2016-09-19 17:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:15:12 UTC to 2016-09-19 18:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:35:12 UTC to 2016-09-19 18:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:55:12 UTC to 2016-09-19 18:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:15:12 UTC to 2016-09-19 19:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:35:12 UTC to 2016-09-19 19:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:55:12 UTC to 2016-09-19 19:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:15:12 UTC to 2016-09-19 20:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:35:12 UTC to 2016-09-19 20:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:55:12 UTC to 2016-09-19 20:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:15:12 UTC to 2016-09-19 21:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:35:12 UTC to 2016-09-19 21:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:55:12 UTC to 2016-09-19 21:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:15:12 UTC to 2016-09-19 22:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:35:12 UTC to 2016-09-19 22:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:55:12 UTC to 2016-09-19 22:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:15:12 UTC to 2016-09-19 23:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:35:12 UTC to 2016-09-19 23:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:55:12 UTC to 2016-09-19 23:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:15:12 UTC to 2016-09-20 00:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:35:12 UTC to 2016-09-20 00:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:55:12 UTC to 2016-09-20 00:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:15:12 UTC to 2016-09-20 01:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:35:12 UTC to 2016-09-20 01:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:55:12 UTC to 2016-09-20 01:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:15:12 UTC to 2016-09-20 02:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:35:12 UTC to 2016-09-20 02:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:55:12 UTC to 2016-09-20 02:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:15:12 UTC to 2016-09-20 03:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:35:12 UTC to 2016-09-20 03:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:55:12 UTC to 2016-09-20 03:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:15:12 UTC to 2016-09-20 04:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:35:12 UTC to 2016-09-20 04:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:55:12 UTC to 2016-09-20 04:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:15:12 UTC to 2016-09-20 05:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:35:12 UTC to 2016-09-20 05:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:55:12 UTC to 2016-09-20 05:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:15:12 UTC to 2016-09-20 06:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:35:12 UTC to 2016-09-20 06:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:55:12 UTC to 2016-09-20 06:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:15:12 UTC to 2016-09-20 07:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:35:12 UTC to 2016-09-20 07:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:55:12 UTC to 2016-09-20 07:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:15:12 UTC to 2016-09-20 08:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:35:12 UTC to 2016-09-20 08:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:55:12 UTC to 2016-09-20 08:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:15:12 UTC to 2016-09-20 09:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:35:12 UTC to 2016-09-20 09:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:55:12 UTC to 2016-09-20 09:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:15:12 UTC to 2016-09-20 10:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:35:12 UTC to 2016-09-20 10:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:55:12 UTC to 2016-09-20 10:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:15:12 UTC to 2016-09-20 11:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:35:12 UTC to 2016-09-20 11:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:55:11 UTC to 2016-09-20 11:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:15:11 UTC to 2016-09-20 12:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:35:11 UTC to 2016-09-20 12:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:55:11 UTC to 2016-09-20 12:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:15:12 UTC to 2016-09-20 13:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:35:12 UTC to 2016-09-20 13:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:55:12 UTC to 2016-09-20 13:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:15:11 UTC to 2016-09-20 14:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:35:12 UTC to 2016-09-20 14:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:55:11 UTC to 2016-09-20 14:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:15:11 UTC to 2016-09-20 15:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:35:11 UTC to 2016-09-20 15:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:55:11 UTC to 2016-09-20 15:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:15:11 UTC to 2016-09-20 16:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:35:11 UTC to 2016-09-20 16:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:55:11 UTC to 2016-09-20 16:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:15:11 UTC to 2016-09-20 17:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:35:11 UTC to 2016-09-20 17:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:55:11 UTC to 2016-09-20 17:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:15:11 UTC to 2016-09-20 18:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:35:11 UTC to 2016-09-20 18:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:55:11 UTC to 2016-09-20 18:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:15:11 UTC to 2016-09-20 19:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:35:11 UTC to 2016-09-20 19:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:55:11 UTC to 2016-09-20 19:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:15:11 UTC to 2016-09-20 20:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:35:11 UTC to 2016-09-20 20:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:55:11 UTC to 2016-09-20 20:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:15:11 UTC to 2016-09-20 21:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:35:11 UTC to 2016-09-20 21:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:55:11 UTC to 2016-09-20 21:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:15:11 UTC to 2016-09-20 22:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:35:11 UTC to 2016-09-20 22:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:55:11 UTC to 2016-09-20 22:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:15:11 UTC to 2016-09-20 23:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:35:11 UTC to 2016-09-20 23:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:55:11 UTC to 2016-09-20 23:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:15:11 UTC to 2016-09-21 00:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:35:11 UTC to 2016-09-21 00:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:55:11 UTC to 2016-09-21 00:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:15:11 UTC to 2016-09-21 01:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:35:11 UTC to 2016-09-21 01:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:55:11 UTC to 2016-09-21 01:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:15:11 UTC to 2016-09-21 02:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:35:11 UTC to 2016-09-21 02:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:55:11 UTC to 2016-09-21 02:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:15:11 UTC to 2016-09-21 03:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:35:11 UTC to 2016-09-21 03:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:55:11 UTC to 2016-09-21 03:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:15:11 UTC to 2016-09-21 04:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:35:11 UTC to 2016-09-21 04:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:55:11 UTC to 2016-09-21 04:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:15:11 UTC to 2016-09-21 05:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:35:11 UTC to 2016-09-21 05:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:55:11 UTC to 2016-09-21 05:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:15:11 UTC to 2016-09-21 06:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:35:11 UTC to 2016-09-21 06:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:55:11 UTC to 2016-09-21 06:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:15:11 UTC to 2016-09-21 07:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:35:11 UTC to 2016-09-21 07:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:55:11 UTC to 2016-09-21 07:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:15:11 UTC to 2016-09-21 08:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:35:11 UTC to 2016-09-21 08:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:55:11 UTC to 2016-09-21 08:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:15:11 UTC to 2016-09-21 09:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:35:11 UTC to 2016-09-21 09:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:55:11 UTC to 2016-09-21 09:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:15:11 UTC to 2016-09-21 10:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:35:11 UTC to 2016-09-21 10:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:55:11 UTC to 2016-09-21 10:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:15:11 UTC to 2016-09-21 11:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:35:11 UTC to 2016-09-21 11:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:55:11 UTC to 2016-09-21 11:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:15:11 UTC to 2016-09-21 12:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:35:11 UTC to 2016-09-21 12:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:55:11 UTC to 2016-09-21 12:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:15:11 UTC to 2016-09-21 13:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:35:11 UTC to 2016-09-21 13:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:55:11 UTC to 2016-09-21 13:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:15:11 UTC to 2016-09-21 14:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:35:10 UTC to 2016-09-21 14:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:55:11 UTC to 2016-09-21 14:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:15:11 UTC to 2016-09-21 15:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:35:11 UTC to 2016-09-21 15:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:55:11 UTC to 2016-09-21 15:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:15:10 UTC to 2016-09-21 16:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:35:11 UTC to 2016-09-21 16:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:55:10 UTC to 2016-09-21 16:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:15:10 UTC to 2016-09-21 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:35:10 UTC to 2016-09-21 17:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:55:10 UTC to 2016-09-21 17:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:15:10 UTC to 2016-09-21 18:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:35:10 UTC to 2016-09-21 18:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:55:10 UTC to 2016-09-21 18:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:15:11 UTC to 2016-09-21 19:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:35:10 UTC to 2016-09-21 19:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:55:10 UTC to 2016-09-21 19:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:15:10 UTC to 2016-09-21 20:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:35:10 UTC to 2016-09-21 20:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:55:10 UTC to 2016-09-21 20:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:15:10 UTC to 2016-09-21 21:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:35:10 UTC to 2016-09-21 21:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:55:10 UTC to 2016-09-21 21:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:15:10 UTC to 2016-09-21 22:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:35:10 UTC to 2016-09-21 22:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:55:10 UTC to 2016-09-21 22:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:15:10 UTC to 2016-09-21 23:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:35:10 UTC to 2016-09-21 23:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:55:10 UTC to 2016-09-21 23:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:15:10 UTC to 2016-09-22 00:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:35:10 UTC to 2016-09-22 00:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:55:10 UTC to 2016-09-22 00:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:15:10 UTC to 2016-09-22 01:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:35:10 UTC to 2016-09-22 01:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:55:10 UTC to 2016-09-22 01:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:15:10 UTC to 2016-09-22 02:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:35:10 UTC to 2016-09-22 02:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:55:10 UTC to 2016-09-22 02:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:15:10 UTC to 2016-09-22 03:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:35:10 UTC to 2016-09-22 03:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:55:10 UTC to 2016-09-22 03:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:15:10 UTC to 2016-09-22 04:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:35:10 UTC to 2016-09-22 04:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:55:10 UTC to 2016-09-22 04:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:15:10 UTC to 2016-09-22 05:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:35:10 UTC to 2016-09-22 05:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:55:10 UTC to 2016-09-22 05:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:15:10 UTC to 2016-09-22 06:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:35:10 UTC to 2016-09-22 06:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:55:10 UTC to 2016-09-22 06:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:15:10 UTC to 2016-09-22 07:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:35:10 UTC to 2016-09-22 07:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:55:10 UTC to 2016-09-22 07:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:15:10 UTC to 2016-09-22 08:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:35:10 UTC to 2016-09-22 08:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:55:10 UTC to 2016-09-22 08:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:15:10 UTC to 2016-09-22 09:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:35:10 UTC to 2016-09-22 09:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:55:10 UTC to 2016-09-22 09:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:15:10 UTC to 2016-09-22 10:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:35:10 UTC to 2016-09-22 10:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:55:10 UTC to 2016-09-22 10:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:15:10 UTC to 2016-09-22 11:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:35:10 UTC to 2016-09-22 11:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:55:10 UTC to 2016-09-22 11:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:15:10 UTC to 2016-09-22 12:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:35:10 UTC to 2016-09-22 12:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:55:10 UTC to 2016-09-22 12:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:15:10 UTC to 2016-09-22 13:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:35:10 UTC to 2016-09-22 13:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:55:10 UTC to 2016-09-22 13:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:15:10 UTC to 2016-09-22 14:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:35:10 UTC to 2016-09-22 14:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:55:10 UTC to 2016-09-22 14:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:15:10 UTC to 2016-09-22 15:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:35:10 UTC to 2016-09-22 15:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:55:10 UTC to 2016-09-22 15:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:15:10 UTC to 2016-09-22 16:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:35:10 UTC to 2016-09-22 16:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:55:09 UTC to 2016-09-22 16:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:15:10 UTC to 2016-09-22 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:35:10 UTC to 2016-09-22 17:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:55:10 UTC to 2016-09-22 17:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:15:09 UTC to 2016-09-22 18:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:35:09 UTC to 2016-09-22 18:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:55:09 UTC to 2016-09-22 18:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:15:09 UTC to 2016-09-22 19:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:35:09 UTC to 2016-09-22 19:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:55:09 UTC to 2016-09-22 19:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:15:09 UTC to 2016-09-22 20:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:35:09 UTC to 2016-09-22 20:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:55:09 UTC to 2016-09-22 20:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:15:10 UTC to 2016-09-22 21:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:35:09 UTC to 2016-09-22 21:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:55:09 UTC to 2016-09-22 21:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:15:09 UTC to 2016-09-22 22:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:35:09 UTC to 2016-09-22 22:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:55:09 UTC to 2016-09-22 22:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:15:09 UTC to 2016-09-22 23:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:35:09 UTC to 2016-09-22 23:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:55:09 UTC to 2016-09-22 23:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:15:09 UTC to 2016-09-23 00:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:35:09 UTC to 2016-09-23 00:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:55:09 UTC to 2016-09-23 00:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:15:09 UTC to 2016-09-23 01:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:35:09 UTC to 2016-09-23 01:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:55:09 UTC to 2016-09-23 01:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:15:09 UTC to 2016-09-23 02:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:35:09 UTC to 2016-09-23 02:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:55:09 UTC to 2016-09-23 02:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:15:09 UTC to 2016-09-23 03:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:35:09 UTC to 2016-09-23 03:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:55:09 UTC to 2016-09-23 03:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:15:09 UTC to 2016-09-23 04:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:35:09 UTC to 2016-09-23 04:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:55:09 UTC to 2016-09-23 04:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:15:09 UTC to 2016-09-23 05:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:35:09 UTC to 2016-09-23 05:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:55:09 UTC to 2016-09-23 05:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 15:36:14 UTC to 2016-09-24 15:36:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 15:46:14 UTC to 2016-09-24 15:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:06:14 UTC to 2016-09-24 16:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:26:14 UTC to 2016-09-24 16:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:46:14 UTC to 2016-09-24 16:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:06:14 UTC to 2016-09-24 17:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:26:14 UTC to 2016-09-24 17:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:46:14 UTC to 2016-09-24 17:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:06:14 UTC to 2016-09-24 18:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:26:14 UTC to 2016-09-24 18:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:46:14 UTC to 2016-09-24 18:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:06:14 UTC to 2016-09-24 19:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:26:14 UTC to 2016-09-24 19:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:46:14 UTC to 2016-09-24 19:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:06:14 UTC to 2016-09-24 20:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:26:14 UTC to 2016-09-24 20:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:46:14 UTC to 2016-09-24 20:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:06:14 UTC to 2016-09-24 21:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:26:14 UTC to 2016-09-24 21:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:46:14 UTC to 2016-09-24 21:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:06:14 UTC to 2016-09-24 22:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:26:14 UTC to 2016-09-24 22:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:46:14 UTC to 2016-09-24 22:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:06:14 UTC to 2016-09-24 23:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:26:14 UTC to 2016-09-24 23:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:46:14 UTC to 2016-09-24 23:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:06:14 UTC to 2016-09-25 00:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:26:14 UTC to 2016-09-25 00:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:46:14 UTC to 2016-09-25 00:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:06:14 UTC to 2016-09-25 01:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:26:14 UTC to 2016-09-25 01:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:46:14 UTC to 2016-09-25 01:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:06:14 UTC to 2016-09-25 02:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:26:14 UTC to 2016-09-25 02:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:46:14 UTC to 2016-09-25 02:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:06:14 UTC to 2016-09-25 03:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:26:14 UTC to 2016-09-25 03:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:46:14 UTC to 2016-09-25 03:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:06:14 UTC to 2016-09-25 04:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:26:14 UTC to 2016-09-25 04:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:46:14 UTC to 2016-09-25 04:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:06:14 UTC to 2016-09-25 05:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:26:14 UTC to 2016-09-25 05:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:46:14 UTC to 2016-09-25 05:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:06:14 UTC to 2016-09-25 06:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:26:14 UTC to 2016-09-25 06:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:46:14 UTC to 2016-09-25 06:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:06:14 UTC to 2016-09-25 07:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:26:14 UTC to 2016-09-25 07:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:46:14 UTC to 2016-09-25 07:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:06:14 UTC to 2016-09-25 08:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:26:14 UTC to 2016-09-25 08:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:46:14 UTC to 2016-09-25 08:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:06:14 UTC to 2016-09-25 09:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:26:14 UTC to 2016-09-25 09:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:46:13 UTC to 2016-09-25 09:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:06:14 UTC to 2016-09-25 10:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:26:13 UTC to 2016-09-25 10:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:46:14 UTC to 2016-09-25 10:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:06:13 UTC to 2016-09-25 11:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:26:14 UTC to 2016-09-25 11:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:46:13 UTC to 2016-09-25 11:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:06:13 UTC to 2016-09-25 12:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:26:13 UTC to 2016-09-25 12:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:46:13 UTC to 2016-09-25 12:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:06:14 UTC to 2016-09-25 13:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:26:13 UTC to 2016-09-25 13:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:46:13 UTC to 2016-09-25 13:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:06:13 UTC to 2016-09-25 14:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:26:13 UTC to 2016-09-25 14:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:46:13 UTC to 2016-09-25 14:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:06:13 UTC to 2016-09-25 15:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:26:13 UTC to 2016-09-25 15:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:46:13 UTC to 2016-09-25 15:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:06:13 UTC to 2016-09-25 16:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:26:13 UTC to 2016-09-25 16:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:46:13 UTC to 2016-09-25 16:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:06:13 UTC to 2016-09-25 17:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:26:13 UTC to 2016-09-25 17:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:46:13 UTC to 2016-09-25 17:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:06:13 UTC to 2016-09-25 18:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:26:13 UTC to 2016-09-25 18:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:46:13 UTC to 2016-09-25 18:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:06:13 UTC to 2016-09-25 19:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:26:13 UTC to 2016-09-25 19:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:46:13 UTC to 2016-09-25 19:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:06:13 UTC to 2016-09-25 20:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:26:13 UTC to 2016-09-25 20:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:46:13 UTC to 2016-09-25 20:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:06:13 UTC to 2016-09-25 21:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:26:13 UTC to 2016-09-25 21:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:46:13 UTC to 2016-09-25 21:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:06:13 UTC to 2016-09-25 22:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:26:13 UTC to 2016-09-25 22:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:46:13 UTC to 2016-09-25 22:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:06:13 UTC to 2016-09-25 23:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:26:13 UTC to 2016-09-25 23:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:46:13 UTC to 2016-09-25 23:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:06:13 UTC to 2016-09-26 00:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:26:13 UTC to 2016-09-26 00:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:46:13 UTC to 2016-09-26 00:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:06:13 UTC to 2016-09-26 01:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:26:13 UTC to 2016-09-26 01:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:46:13 UTC to 2016-09-26 01:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:06:13 UTC to 2016-09-26 02:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:26:13 UTC to 2016-09-26 02:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:46:13 UTC to 2016-09-26 02:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:06:13 UTC to 2016-09-26 03:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:26:13 UTC to 2016-09-26 03:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:46:13 UTC to 2016-09-26 03:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:06:13 UTC to 2016-09-26 04:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:26:13 UTC to 2016-09-26 04:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:46:13 UTC to 2016-09-26 04:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:06:13 UTC to 2016-09-26 05:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:26:13 UTC to 2016-09-26 05:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:46:13 UTC to 2016-09-26 05:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:06:13 UTC to 2016-09-26 06:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:26:13 UTC to 2016-09-26 06:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:46:13 UTC to 2016-09-26 06:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:06:13 UTC to 2016-09-26 07:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:26:13 UTC to 2016-09-26 07:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:46:13 UTC to 2016-09-26 07:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:06:13 UTC to 2016-09-26 08:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:26:13 UTC to 2016-09-26 08:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:46:13 UTC to 2016-09-26 08:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:06:13 UTC to 2016-09-26 09:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:26:13 UTC to 2016-09-26 09:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:46:13 UTC to 2016-09-26 09:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:06:13 UTC to 2016-09-26 10:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:26:13 UTC to 2016-09-26 10:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:46:13 UTC to 2016-09-26 10:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:06:13 UTC to 2016-09-26 11:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:26:13 UTC to 2016-09-26 11:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:46:13 UTC to 2016-09-26 11:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:06:13 UTC to 2016-09-26 12:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:26:13 UTC to 2016-09-26 12:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:46:13 UTC to 2016-09-26 12:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:06:13 UTC to 2016-09-26 13:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:26:12 UTC to 2016-09-26 13:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:46:13 UTC to 2016-09-26 13:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:06:13 UTC to 2016-09-26 14:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:26:12 UTC to 2016-09-26 14:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:46:12 UTC to 2016-09-26 14:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:06:12 UTC to 2016-09-26 15:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:26:12 UTC to 2016-09-26 15:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:46:12 UTC to 2016-09-26 15:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:06:12 UTC to 2016-09-26 16:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:26:13 UTC to 2016-09-26 16:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:46:12 UTC to 2016-09-26 16:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:06:12 UTC to 2016-09-26 17:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:26:12 UTC to 2016-09-26 17:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:46:12 UTC to 2016-09-26 17:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:06:12 UTC to 2016-09-26 18:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:26:12 UTC to 2016-09-26 18:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:46:12 UTC to 2016-09-26 18:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:06:12 UTC to 2016-09-26 19:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:26:12 UTC to 2016-09-26 19:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:46:12 UTC to 2016-09-26 19:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:06:12 UTC to 2016-09-26 20:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:26:12 UTC to 2016-09-26 20:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:46:12 UTC to 2016-09-26 20:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:06:12 UTC to 2016-09-26 21:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:26:12 UTC to 2016-09-26 21:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:46:12 UTC to 2016-09-26 21:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:06:12 UTC to 2016-09-26 22:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:26:12 UTC to 2016-09-26 22:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:46:12 UTC to 2016-09-26 22:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:06:12 UTC to 2016-09-26 23:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:26:12 UTC to 2016-09-26 23:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:46:12 UTC to 2016-09-26 23:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:06:12 UTC to 2016-09-27 00:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:26:12 UTC to 2016-09-27 00:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:46:12 UTC to 2016-09-27 00:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:06:12 UTC to 2016-09-27 01:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:26:12 UTC to 2016-09-27 01:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:46:12 UTC to 2016-09-27 01:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:06:12 UTC to 2016-09-27 02:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:26:12 UTC to 2016-09-27 02:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:46:12 UTC to 2016-09-27 02:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:06:12 UTC to 2016-09-27 03:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:26:12 UTC to 2016-09-27 03:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:46:12 UTC to 2016-09-27 03:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:06:12 UTC to 2016-09-27 04:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:26:12 UTC to 2016-09-27 04:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:46:12 UTC to 2016-09-27 04:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:06:12 UTC to 2016-09-27 05:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:26:12 UTC to 2016-09-27 05:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:46:12 UTC to 2016-09-27 05:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:06:12 UTC to 2016-09-27 06:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:26:12 UTC to 2016-09-27 06:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:46:12 UTC to 2016-09-27 06:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:06:12 UTC to 2016-09-27 07:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:26:12 UTC to 2016-09-27 07:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:46:12 UTC to 2016-09-27 07:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:06:12 UTC to 2016-09-27 08:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:26:12 UTC to 2016-09-27 08:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:46:12 UTC to 2016-09-27 08:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:06:12 UTC to 2016-09-27 09:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:26:12 UTC to 2016-09-27 09:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:46:12 UTC to 2016-09-27 09:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 10:06:12 UTC to 2016-09-27 10:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:07:15 UTC to 2016-09-27 22:07:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:17:15 UTC to 2016-09-27 22:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:37:15 UTC to 2016-09-27 22:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:57:15 UTC to 2016-09-27 22:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:17:15 UTC to 2016-09-27 23:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:37:15 UTC to 2016-09-27 23:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:57:15 UTC to 2016-09-27 23:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:17:15 UTC to 2016-09-28 00:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:37:15 UTC to 2016-09-28 00:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:57:15 UTC to 2016-09-28 00:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:17:15 UTC to 2016-09-28 01:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:37:15 UTC to 2016-09-28 01:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:57:15 UTC to 2016-09-28 01:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:17:15 UTC to 2016-09-28 02:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:37:15 UTC to 2016-09-28 02:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:57:15 UTC to 2016-09-28 02:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:17:15 UTC to 2016-09-28 03:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:37:19 UTC to 2016-09-28 03:37:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:57:15 UTC to 2016-09-28 03:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:17:15 UTC to 2016-09-28 04:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:37:15 UTC to 2016-09-28 04:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:57:15 UTC to 2016-09-28 04:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:17:15 UTC to 2016-09-28 05:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:37:15 UTC to 2016-09-28 05:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:57:14 UTC to 2016-09-28 05:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:17:14 UTC to 2016-09-28 06:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:37:14 UTC to 2016-09-28 06:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:57:21 UTC to 2016-09-28 06:57:41 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:17:14 UTC to 2016-09-28 07:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:37:15 UTC to 2016-09-28 07:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:57:14 UTC to 2016-09-28 07:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:17:14 UTC to 2016-09-28 08:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:37:14 UTC to 2016-09-28 08:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:57:14 UTC to 2016-09-28 08:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:17:14 UTC to 2016-09-28 09:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:37:14 UTC to 2016-09-28 09:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:57:14 UTC to 2016-09-28 09:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:17:14 UTC to 2016-09-28 10:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:37:14 UTC to 2016-09-28 10:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:57:14 UTC to 2016-09-28 10:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:17:14 UTC to 2016-09-28 11:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:37:14 UTC to 2016-09-28 11:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:57:14 UTC to 2016-09-28 11:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:17:14 UTC to 2016-09-28 12:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:37:14 UTC to 2016-09-28 12:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:57:14 UTC to 2016-09-28 12:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:17:14 UTC to 2016-09-28 13:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:37:14 UTC to 2016-09-28 13:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:57:14 UTC to 2016-09-28 13:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:17:14 UTC to 2016-09-28 14:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:37:14 UTC to 2016-09-28 14:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:57:14 UTC to 2016-09-28 14:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:17:14 UTC to 2016-09-28 15:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:37:14 UTC to 2016-09-28 15:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:57:14 UTC to 2016-09-28 15:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:17:14 UTC to 2016-09-28 16:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:37:14 UTC to 2016-09-28 16:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:57:14 UTC to 2016-09-28 16:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:17:14 UTC to 2016-09-28 17:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:37:14 UTC to 2016-09-28 17:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:57:14 UTC to 2016-09-28 17:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:17:14 UTC to 2016-09-28 18:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:37:14 UTC to 2016-09-28 18:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:57:14 UTC to 2016-09-28 18:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:17:14 UTC to 2016-09-28 19:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:37:14 UTC to 2016-09-28 19:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:57:14 UTC to 2016-09-28 19:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:17:14 UTC to 2016-09-28 20:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:37:14 UTC to 2016-09-28 20:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:57:14 UTC to 2016-09-28 20:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:17:14 UTC to 2016-09-28 21:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:37:14 UTC to 2016-09-28 21:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:57:14 UTC to 2016-09-28 21:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:17:14 UTC to 2016-09-28 22:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:37:14 UTC to 2016-09-28 22:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:57:14 UTC to 2016-09-28 22:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:17:14 UTC to 2016-09-28 23:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:37:14 UTC to 2016-09-28 23:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:57:14 UTC to 2016-09-28 23:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:17:14 UTC to 2016-09-29 00:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:37:14 UTC to 2016-09-29 00:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:57:14 UTC to 2016-09-29 00:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:17:14 UTC to 2016-09-29 01:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:37:14 UTC to 2016-09-29 01:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:57:14 UTC to 2016-09-29 01:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:17:14 UTC to 2016-09-29 02:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:37:14 UTC to 2016-09-29 02:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:57:14 UTC to 2016-09-29 02:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:17:14 UTC to 2016-09-29 03:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:37:14 UTC to 2016-09-29 03:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:57:14 UTC to 2016-09-29 03:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:17:14 UTC to 2016-09-29 04:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:37:14 UTC to 2016-09-29 04:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:57:14 UTC to 2016-09-29 04:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:17:14 UTC to 2016-09-29 05:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:37:14 UTC to 2016-09-29 05:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:57:14 UTC to 2016-09-29 05:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:17:14 UTC to 2016-09-29 06:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:37:14 UTC to 2016-09-29 06:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:57:14 UTC to 2016-09-29 06:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:17:14 UTC to 2016-09-29 07:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:37:14 UTC to 2016-09-29 07:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:57:14 UTC to 2016-09-29 07:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:17:14 UTC to 2016-09-29 08:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:37:14 UTC to 2016-09-29 08:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:57:14 UTC to 2016-09-29 08:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:17:14 UTC to 2016-09-29 09:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:37:13 UTC to 2016-09-29 09:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:57:13 UTC to 2016-09-29 09:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:17:13 UTC to 2016-09-29 10:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:37:13 UTC to 2016-09-29 10:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:57:13 UTC to 2016-09-29 10:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:17:13 UTC to 2016-09-29 11:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:37:13 UTC to 2016-09-29 11:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:57:13 UTC to 2016-09-29 11:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:17:13 UTC to 2016-09-29 12:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:37:13 UTC to 2016-09-29 12:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:57:13 UTC to 2016-09-29 12:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:17:13 UTC to 2016-09-29 13:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:37:13 UTC to 2016-09-29 13:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:57:13 UTC to 2016-09-29 13:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:17:13 UTC to 2016-09-29 14:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:37:13 UTC to 2016-09-29 14:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:57:13 UTC to 2016-09-29 14:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:17:15 UTC to 2016-09-29 15:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:37:13 UTC to 2016-09-29 15:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:57:13 UTC to 2016-09-29 15:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:17:13 UTC to 2016-09-29 16:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:37:13 UTC to 2016-09-29 16:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:57:13 UTC to 2016-09-29 16:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:17:13 UTC to 2016-09-29 17:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:37:13 UTC to 2016-09-29 17:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:57:13 UTC to 2016-09-29 17:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:17:13 UTC to 2016-09-29 18:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:37:13 UTC to 2016-09-29 18:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:57:13 UTC to 2016-09-29 18:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:17:13 UTC to 2016-09-29 19:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:37:13 UTC to 2016-09-29 19:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:57:13 UTC to 2016-09-29 19:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:17:13 UTC to 2016-09-29 20:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:37:13 UTC to 2016-09-29 20:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:57:13 UTC to 2016-09-29 20:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:17:13 UTC to 2016-09-29 21:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:37:13 UTC to 2016-09-29 21:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:57:13 UTC to 2016-09-29 21:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:17:13 UTC to 2016-09-29 22:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:37:13 UTC to 2016-09-29 22:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:57:13 UTC to 2016-09-29 22:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:17:13 UTC to 2016-09-29 23:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:37:13 UTC to 2016-09-29 23:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:57:13 UTC to 2016-09-29 23:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:17:13 UTC to 2016-09-30 00:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:37:13 UTC to 2016-09-30 00:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:57:13 UTC to 2016-09-30 00:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:17:13 UTC to 2016-09-30 01:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:37:13 UTC to 2016-09-30 01:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:57:13 UTC to 2016-09-30 01:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:17:13 UTC to 2016-09-30 02:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:37:13 UTC to 2016-09-30 02:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:57:13 UTC to 2016-09-30 02:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:17:13 UTC to 2016-09-30 03:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:37:13 UTC to 2016-09-30 03:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:57:13 UTC to 2016-09-30 03:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:17:13 UTC to 2016-09-30 04:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:37:13 UTC to 2016-09-30 04:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:57:13 UTC to 2016-09-30 04:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:17:13 UTC to 2016-09-30 05:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:37:13 UTC to 2016-09-30 05:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:57:13 UTC to 2016-09-30 05:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:17:13 UTC to 2016-09-30 06:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:37:13 UTC to 2016-09-30 06:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:57:13 UTC to 2016-09-30 06:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:17:13 UTC to 2016-09-30 07:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:37:13 UTC to 2016-09-30 07:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:57:13 UTC to 2016-09-30 07:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:17:13 UTC to 2016-09-30 08:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:37:13 UTC to 2016-09-30 08:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:57:13 UTC to 2016-09-30 08:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:17:13 UTC to 2016-09-30 09:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:37:13 UTC to 2016-09-30 09:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:57:13 UTC to 2016-09-30 09:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:17:13 UTC to 2016-09-30 10:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:37:13 UTC to 2016-09-30 10:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:57:13 UTC to 2016-09-30 10:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:17:13 UTC to 2016-09-30 11:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:37:13 UTC to 2016-09-30 11:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:57:13 UTC to 2016-09-30 11:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:17:12 UTC to 2016-09-30 12:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:37:13 UTC to 2016-09-30 12:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:57:13 UTC to 2016-09-30 12:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:17:12 UTC to 2016-09-30 13:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:37:12 UTC to 2016-09-30 13:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:57:12 UTC to 2016-09-30 13:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:17:12 UTC to 2016-09-30 14:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:37:12 UTC to 2016-09-30 14:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:57:12 UTC to 2016-09-30 14:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:17:12 UTC to 2016-09-30 15:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:37:12 UTC to 2016-09-30 15:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:57:12 UTC to 2016-09-30 15:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:17:12 UTC to 2016-09-30 16:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:37:12 UTC to 2016-09-30 16:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:57:12 UTC to 2016-09-30 16:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:17:12 UTC to 2016-09-30 17:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:37:12 UTC to 2016-09-30 17:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:57:12 UTC to 2016-09-30 17:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:17:12 UTC to 2016-09-30 18:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:37:12 UTC to 2016-09-30 18:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:57:12 UTC to 2016-09-30 18:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:17:12 UTC to 2016-09-30 19:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:37:12 UTC to 2016-09-30 19:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:57:12 UTC to 2016-09-30 19:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:17:12 UTC to 2016-09-30 20:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:37:12 UTC to 2016-09-30 20:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:57:12 UTC to 2016-09-30 20:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:17:12 UTC to 2016-09-30 21:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:37:12 UTC to 2016-09-30 21:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:57:12 UTC to 2016-09-30 21:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:17:12 UTC to 2016-09-30 22:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:37:12 UTC to 2016-09-30 22:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:57:12 UTC to 2016-09-30 22:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:17:12 UTC to 2016-09-30 23:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:37:12 UTC to 2016-09-30 23:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:57:12 UTC to 2016-09-30 23:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:17:12 UTC to 2016-10-01 00:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:37:12 UTC to 2016-10-01 00:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:57:12 UTC to 2016-10-01 00:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:17:12 UTC to 2016-10-01 01:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:37:12 UTC to 2016-10-01 01:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:57:12 UTC to 2016-10-01 01:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:17:12 UTC to 2016-10-01 02:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:37:12 UTC to 2016-10-01 02:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:57:12 UTC to 2016-10-01 02:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:17:12 UTC to 2016-10-01 03:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:37:12 UTC to 2016-10-01 03:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:57:12 UTC to 2016-10-01 03:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:17:12 UTC to 2016-10-01 04:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:37:12 UTC to 2016-10-01 04:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:57:12 UTC to 2016-10-01 04:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:17:12 UTC to 2016-10-01 05:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:37:12 UTC to 2016-10-01 05:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:57:12 UTC to 2016-10-01 05:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:17:12 UTC to 2016-10-01 06:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:37:12 UTC to 2016-10-01 06:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:57:12 UTC to 2016-10-01 06:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:17:12 UTC to 2016-10-01 07:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:37:12 UTC to 2016-10-01 07:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:57:12 UTC to 2016-10-01 07:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-09-02 22:09:16 UTC to 2016-09-02 22:09:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:19:16 UTC to 2016-09-02 22:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:39:16 UTC to 2016-09-02 22:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:59:16 UTC to 2016-09-02 22:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:19:16 UTC to 2016-09-02 23:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:39:16 UTC to 2016-09-02 23:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:59:16 UTC to 2016-09-02 23:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:19:16 UTC to 2016-09-03 00:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:39:16 UTC to 2016-09-03 00:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:59:16 UTC to 2016-09-03 00:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:19:16 UTC to 2016-09-03 01:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:39:16 UTC to 2016-09-03 01:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:59:16 UTC to 2016-09-03 01:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:19:16 UTC to 2016-09-03 02:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:39:16 UTC to 2016-09-03 02:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:59:16 UTC to 2016-09-03 02:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:19:16 UTC to 2016-09-03 03:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:39:16 UTC to 2016-09-03 03:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:59:16 UTC to 2016-09-03 03:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:19:16 UTC to 2016-09-03 04:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:39:16 UTC to 2016-09-03 04:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:59:16 UTC to 2016-09-03 04:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:19:16 UTC to 2016-09-03 05:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:39:16 UTC to 2016-09-03 05:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:59:16 UTC to 2016-09-03 05:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:19:16 UTC to 2016-09-03 06:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:39:15 UTC to 2016-09-03 06:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:59:15 UTC to 2016-09-03 06:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:19:15 UTC to 2016-09-03 07:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:39:15 UTC to 2016-09-03 07:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:59:16 UTC to 2016-09-03 07:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:19:15 UTC to 2016-09-03 08:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:39:15 UTC to 2016-09-03 08:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:59:15 UTC to 2016-09-03 08:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:19:15 UTC to 2016-09-03 09:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:39:15 UTC to 2016-09-03 09:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:59:15 UTC to 2016-09-03 09:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:19:15 UTC to 2016-09-03 10:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:39:15 UTC to 2016-09-03 10:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:59:15 UTC to 2016-09-03 10:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:19:15 UTC to 2016-09-03 11:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:39:15 UTC to 2016-09-03 11:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:59:15 UTC to 2016-09-03 11:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:19:15 UTC to 2016-09-03 12:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:39:15 UTC to 2016-09-03 12:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:59:15 UTC to 2016-09-03 12:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:19:15 UTC to 2016-09-03 13:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:39:15 UTC to 2016-09-03 13:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:59:15 UTC to 2016-09-03 13:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:19:15 UTC to 2016-09-03 14:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:39:15 UTC to 2016-09-03 14:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:59:15 UTC to 2016-09-03 14:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:19:15 UTC to 2016-09-03 15:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:39:15 UTC to 2016-09-03 15:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:59:15 UTC to 2016-09-03 15:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:19:15 UTC to 2016-09-03 16:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:39:15 UTC to 2016-09-03 16:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:59:15 UTC to 2016-09-03 16:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:19:15 UTC to 2016-09-03 17:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:39:15 UTC to 2016-09-03 17:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:59:15 UTC to 2016-09-03 17:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:19:15 UTC to 2016-09-03 18:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:39:15 UTC to 2016-09-03 18:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:59:15 UTC to 2016-09-03 18:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:19:15 UTC to 2016-09-03 19:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:39:15 UTC to 2016-09-03 19:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:59:15 UTC to 2016-09-03 19:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:19:15 UTC to 2016-09-03 20:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:39:15 UTC to 2016-09-03 20:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:59:15 UTC to 2016-09-03 20:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:19:15 UTC to 2016-09-03 21:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:39:15 UTC to 2016-09-03 21:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:59:15 UTC to 2016-09-03 21:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:19:15 UTC to 2016-09-03 22:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:39:15 UTC to 2016-09-03 22:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:59:15 UTC to 2016-09-03 22:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:19:15 UTC to 2016-09-03 23:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:39:15 UTC to 2016-09-03 23:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:59:15 UTC to 2016-09-03 23:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:19:15 UTC to 2016-09-04 00:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:39:15 UTC to 2016-09-04 00:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:59:15 UTC to 2016-09-04 00:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:19:15 UTC to 2016-09-04 01:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:39:15 UTC to 2016-09-04 01:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:59:15 UTC to 2016-09-04 01:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:19:15 UTC to 2016-09-04 02:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:39:15 UTC to 2016-09-04 02:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:59:15 UTC to 2016-09-04 02:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:19:15 UTC to 2016-09-04 03:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:39:15 UTC to 2016-09-04 03:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:59:15 UTC to 2016-09-04 03:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:19:15 UTC to 2016-09-04 04:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:39:15 UTC to 2016-09-04 04:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:59:15 UTC to 2016-09-04 04:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:19:15 UTC to 2016-09-04 05:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:39:15 UTC to 2016-09-04 05:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:59:15 UTC to 2016-09-04 05:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:19:15 UTC to 2016-09-04 06:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:39:15 UTC to 2016-09-04 06:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:59:15 UTC to 2016-09-04 06:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:19:15 UTC to 2016-09-04 07:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:39:15 UTC to 2016-09-04 07:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:59:15 UTC to 2016-09-04 07:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:19:14 UTC to 2016-09-04 08:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:39:14 UTC to 2016-09-04 08:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:59:15 UTC to 2016-09-04 08:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:19:15 UTC to 2016-09-04 09:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:39:14 UTC to 2016-09-04 09:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:59:15 UTC to 2016-09-04 09:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:19:14 UTC to 2016-09-04 10:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:39:14 UTC to 2016-09-04 10:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:59:14 UTC to 2016-09-04 10:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:19:15 UTC to 2016-09-04 11:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:39:14 UTC to 2016-09-04 11:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:59:14 UTC to 2016-09-04 11:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:19:14 UTC to 2016-09-04 12:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:39:14 UTC to 2016-09-04 12:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:59:14 UTC to 2016-09-04 12:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 13:19:14 UTC to 2016-09-04 13:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 23:22:35 UTC to 2016-09-04 23:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 23:42:35 UTC to 2016-09-04 23:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:02:35 UTC to 2016-09-05 00:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:22:35 UTC to 2016-09-05 00:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:42:35 UTC to 2016-09-05 00:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:02:35 UTC to 2016-09-05 01:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:22:35 UTC to 2016-09-05 01:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:42:35 UTC to 2016-09-05 01:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:02:35 UTC to 2016-09-05 02:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:22:35 UTC to 2016-09-05 02:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:42:35 UTC to 2016-09-05 02:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:02:35 UTC to 2016-09-05 03:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:22:35 UTC to 2016-09-05 03:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:42:35 UTC to 2016-09-05 03:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:02:35 UTC to 2016-09-05 04:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:22:35 UTC to 2016-09-05 04:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:42:35 UTC to 2016-09-05 04:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:02:35 UTC to 2016-09-05 05:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:22:35 UTC to 2016-09-05 05:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:42:35 UTC to 2016-09-05 05:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:02:35 UTC to 2016-09-05 06:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:22:35 UTC to 2016-09-05 06:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:42:35 UTC to 2016-09-05 06:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:02:35 UTC to 2016-09-05 07:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:22:35 UTC to 2016-09-05 07:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:42:35 UTC to 2016-09-05 07:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:02:35 UTC to 2016-09-05 08:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:22:35 UTC to 2016-09-05 08:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:42:35 UTC to 2016-09-05 08:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:02:35 UTC to 2016-09-05 09:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:22:35 UTC to 2016-09-05 09:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:42:35 UTC to 2016-09-05 09:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:02:35 UTC to 2016-09-05 10:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:22:35 UTC to 2016-09-05 10:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:42:35 UTC to 2016-09-05 10:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:02:35 UTC to 2016-09-05 11:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:22:34 UTC to 2016-09-05 11:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:42:35 UTC to 2016-09-05 11:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:02:34 UTC to 2016-09-05 12:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:22:34 UTC to 2016-09-05 12:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:42:34 UTC to 2016-09-05 12:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:02:34 UTC to 2016-09-05 13:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:22:34 UTC to 2016-09-05 13:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:42:34 UTC to 2016-09-05 13:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:02:34 UTC to 2016-09-05 14:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:22:34 UTC to 2016-09-05 14:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:42:34 UTC to 2016-09-05 14:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:02:34 UTC to 2016-09-05 15:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:22:34 UTC to 2016-09-05 15:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:42:34 UTC to 2016-09-05 15:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:02:34 UTC to 2016-09-05 16:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:22:34 UTC to 2016-09-05 16:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:42:34 UTC to 2016-09-05 16:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:02:34 UTC to 2016-09-05 17:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:22:34 UTC to 2016-09-05 17:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:42:34 UTC to 2016-09-05 17:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:02:34 UTC to 2016-09-05 18:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:22:34 UTC to 2016-09-05 18:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:42:34 UTC to 2016-09-05 18:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:02:34 UTC to 2016-09-05 19:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:22:34 UTC to 2016-09-05 19:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:42:34 UTC to 2016-09-05 19:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:02:34 UTC to 2016-09-05 20:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:22:34 UTC to 2016-09-05 20:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:42:34 UTC to 2016-09-05 20:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:02:34 UTC to 2016-09-05 21:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:22:34 UTC to 2016-09-05 21:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:42:34 UTC to 2016-09-05 21:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:02:34 UTC to 2016-09-05 22:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:22:34 UTC to 2016-09-05 22:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:42:34 UTC to 2016-09-05 22:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:02:34 UTC to 2016-09-05 23:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:22:34 UTC to 2016-09-05 23:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:42:34 UTC to 2016-09-05 23:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:02:34 UTC to 2016-09-06 00:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:22:34 UTC to 2016-09-06 00:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:42:34 UTC to 2016-09-06 00:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:02:34 UTC to 2016-09-06 01:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:22:34 UTC to 2016-09-06 01:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:42:34 UTC to 2016-09-06 01:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:02:34 UTC to 2016-09-06 02:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:22:34 UTC to 2016-09-06 02:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:42:34 UTC to 2016-09-06 02:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:02:34 UTC to 2016-09-06 03:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:22:34 UTC to 2016-09-06 03:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:42:34 UTC to 2016-09-06 03:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:02:34 UTC to 2016-09-06 04:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:22:34 UTC to 2016-09-06 04:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:42:34 UTC to 2016-09-06 04:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:02:34 UTC to 2016-09-06 05:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:22:34 UTC to 2016-09-06 05:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:42:34 UTC to 2016-09-06 05:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:02:34 UTC to 2016-09-06 06:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:22:34 UTC to 2016-09-06 06:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:42:34 UTC to 2016-09-06 06:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:02:34 UTC to 2016-09-06 07:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:22:34 UTC to 2016-09-06 07:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:42:34 UTC to 2016-09-06 07:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:02:34 UTC to 2016-09-06 08:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:22:34 UTC to 2016-09-06 08:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:42:34 UTC to 2016-09-06 08:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:02:34 UTC to 2016-09-06 09:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:22:34 UTC to 2016-09-06 09:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:42:34 UTC to 2016-09-06 09:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:02:34 UTC to 2016-09-06 10:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:22:34 UTC to 2016-09-06 10:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:42:34 UTC to 2016-09-06 10:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 11:02:34 UTC to 2016-09-06 11:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 11:22:34 UTC to 2016-09-06 11:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:17:02 UTC to 2016-09-07 16:17:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:27:02 UTC to 2016-09-07 16:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:47:02 UTC to 2016-09-07 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:07:02 UTC to 2016-09-07 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:27:02 UTC to 2016-09-07 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:47:02 UTC to 2016-09-07 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:07:11 UTC to 2016-09-07 18:07:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:27:02 UTC to 2016-09-07 18:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:47:02 UTC to 2016-09-07 18:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:07:02 UTC to 2016-09-07 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:27:02 UTC to 2016-09-07 19:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:47:02 UTC to 2016-09-07 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:07:02 UTC to 2016-09-07 20:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:27:02 UTC to 2016-09-07 20:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:47:02 UTC to 2016-09-07 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:07:02 UTC to 2016-09-07 21:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:27:02 UTC to 2016-09-07 21:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:47:02 UTC to 2016-09-07 21:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:07:02 UTC to 2016-09-07 22:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:27:02 UTC to 2016-09-07 22:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:47:02 UTC to 2016-09-07 22:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:07:02 UTC to 2016-09-07 23:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:27:02 UTC to 2016-09-07 23:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:47:02 UTC to 2016-09-07 23:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:07:02 UTC to 2016-09-08 00:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:27:02 UTC to 2016-09-08 00:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:47:02 UTC to 2016-09-08 00:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:07:02 UTC to 2016-09-08 01:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:27:02 UTC to 2016-09-08 01:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:47:02 UTC to 2016-09-08 01:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:07:02 UTC to 2016-09-08 02:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:27:02 UTC to 2016-09-08 02:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:47:02 UTC to 2016-09-08 02:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:07:02 UTC to 2016-09-08 03:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:27:02 UTC to 2016-09-08 03:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:47:02 UTC to 2016-09-08 03:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:07:02 UTC to 2016-09-08 04:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:27:02 UTC to 2016-09-08 04:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:47:02 UTC to 2016-09-08 04:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:07:02 UTC to 2016-09-08 05:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:27:02 UTC to 2016-09-08 05:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:47:02 UTC to 2016-09-08 05:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:07:01 UTC to 2016-09-08 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:27:02 UTC to 2016-09-08 06:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:47:02 UTC to 2016-09-08 06:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:07:01 UTC to 2016-09-08 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:27:01 UTC to 2016-09-08 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:47:01 UTC to 2016-09-08 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:07:01 UTC to 2016-09-08 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:27:01 UTC to 2016-09-08 08:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:47:01 UTC to 2016-09-08 08:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:07:01 UTC to 2016-09-08 09:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:27:01 UTC to 2016-09-08 09:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:47:01 UTC to 2016-09-08 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:07:01 UTC to 2016-09-08 10:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:27:01 UTC to 2016-09-08 10:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:47:01 UTC to 2016-09-08 10:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:07:01 UTC to 2016-09-08 11:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:27:01 UTC to 2016-09-08 11:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:47:01 UTC to 2016-09-08 11:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:07:01 UTC to 2016-09-08 12:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:27:01 UTC to 2016-09-08 12:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:47:01 UTC to 2016-09-08 12:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:07:01 UTC to 2016-09-08 13:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:27:01 UTC to 2016-09-08 13:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:47:01 UTC to 2016-09-08 13:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:07:01 UTC to 2016-09-08 14:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:27:01 UTC to 2016-09-08 14:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:47:01 UTC to 2016-09-08 14:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:07:01 UTC to 2016-09-08 15:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:27:01 UTC to 2016-09-08 15:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:47:01 UTC to 2016-09-08 15:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:07:01 UTC to 2016-09-08 16:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:27:01 UTC to 2016-09-08 16:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:47:01 UTC to 2016-09-08 16:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:07:01 UTC to 2016-09-08 17:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:27:01 UTC to 2016-09-08 17:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:47:01 UTC to 2016-09-08 17:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:07:01 UTC to 2016-09-08 18:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:27:01 UTC to 2016-09-08 18:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:47:01 UTC to 2016-09-08 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:07:01 UTC to 2016-09-08 19:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:27:01 UTC to 2016-09-08 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:47:01 UTC to 2016-09-08 19:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:07:01 UTC to 2016-09-08 20:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:27:01 UTC to 2016-09-08 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:47:01 UTC to 2016-09-08 20:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:07:01 UTC to 2016-09-08 21:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:27:01 UTC to 2016-09-08 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:47:01 UTC to 2016-09-08 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:07:01 UTC to 2016-09-08 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:27:01 UTC to 2016-09-08 22:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:47:01 UTC to 2016-09-08 22:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:07:01 UTC to 2016-09-08 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:27:01 UTC to 2016-09-08 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:47:01 UTC to 2016-09-08 23:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:07:01 UTC to 2016-09-09 00:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:27:01 UTC to 2016-09-09 00:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:47:01 UTC to 2016-09-09 00:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:07:01 UTC to 2016-09-09 01:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:27:01 UTC to 2016-09-09 01:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:47:01 UTC to 2016-09-09 01:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:07:01 UTC to 2016-09-09 02:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:27:01 UTC to 2016-09-09 02:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:47:01 UTC to 2016-09-09 02:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:07:01 UTC to 2016-09-09 03:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:27:01 UTC to 2016-09-09 03:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:47:01 UTC to 2016-09-09 03:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:07:01 UTC to 2016-09-09 04:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:27:01 UTC to 2016-09-09 04:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:47:01 UTC to 2016-09-09 04:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:07:01 UTC to 2016-09-09 05:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:27:01 UTC to 2016-09-09 05:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:47:01 UTC to 2016-09-09 05:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:07:01 UTC to 2016-09-09 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:27:01 UTC to 2016-09-09 06:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:47:01 UTC to 2016-09-09 06:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:07:01 UTC to 2016-09-09 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:27:01 UTC to 2016-09-09 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:47:01 UTC to 2016-09-09 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:07:01 UTC to 2016-09-09 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:27:00 UTC to 2016-09-09 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:47:00 UTC to 2016-09-09 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:07:00 UTC to 2016-09-09 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:27:00 UTC to 2016-09-09 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:47:01 UTC to 2016-09-09 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:07:00 UTC to 2016-09-09 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:27:00 UTC to 2016-09-09 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:47:00 UTC to 2016-09-09 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:07:00 UTC to 2016-09-09 11:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:27:00 UTC to 2016-09-09 11:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:47:00 UTC to 2016-09-09 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:07:00 UTC to 2016-09-09 12:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:27:00 UTC to 2016-09-09 12:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:47:00 UTC to 2016-09-09 12:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:07:00 UTC to 2016-09-09 13:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:27:00 UTC to 2016-09-09 13:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:47:00 UTC to 2016-09-09 13:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:07:00 UTC to 2016-09-09 14:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:27:00 UTC to 2016-09-09 14:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:47:00 UTC to 2016-09-09 14:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:07:00 UTC to 2016-09-09 15:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:27:00 UTC to 2016-09-09 15:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:47:00 UTC to 2016-09-09 15:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:07:00 UTC to 2016-09-09 16:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:27:00 UTC to 2016-09-09 16:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:47:00 UTC to 2016-09-09 16:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:07:00 UTC to 2016-09-09 17:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:27:00 UTC to 2016-09-09 17:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:47:00 UTC to 2016-09-09 17:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:07:00 UTC to 2016-09-09 18:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:27:00 UTC to 2016-09-09 18:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:47:00 UTC to 2016-09-09 18:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:07:00 UTC to 2016-09-09 19:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:27:00 UTC to 2016-09-09 19:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:47:00 UTC to 2016-09-09 19:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:07:00 UTC to 2016-09-09 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:27:00 UTC to 2016-09-09 20:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:47:00 UTC to 2016-09-09 20:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:07:00 UTC to 2016-09-09 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:27:00 UTC to 2016-09-09 21:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:47:00 UTC to 2016-09-09 21:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:07:00 UTC to 2016-09-09 22:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:27:00 UTC to 2016-09-09 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:47:00 UTC to 2016-09-09 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:07:00 UTC to 2016-09-09 23:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:27:00 UTC to 2016-09-09 23:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:47:00 UTC to 2016-09-09 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:07:00 UTC to 2016-09-10 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:27:00 UTC to 2016-09-10 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:47:00 UTC to 2016-09-10 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:07:00 UTC to 2016-09-10 01:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:27:00 UTC to 2016-09-10 01:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:47:00 UTC to 2016-09-10 01:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:07:00 UTC to 2016-09-10 02:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:27:00 UTC to 2016-09-10 02:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:47:00 UTC to 2016-09-10 02:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:07:00 UTC to 2016-09-10 03:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:27:00 UTC to 2016-09-10 03:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:47:00 UTC to 2016-09-10 03:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:07:00 UTC to 2016-09-10 04:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:27:00 UTC to 2016-09-10 04:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:47:00 UTC to 2016-09-10 04:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:07:00 UTC to 2016-09-10 05:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:27:00 UTC to 2016-09-10 05:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:47:00 UTC to 2016-09-10 05:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:07:00 UTC to 2016-09-10 06:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:27:00 UTC to 2016-09-10 06:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:47:00 UTC to 2016-09-10 06:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:07:00 UTC to 2016-09-10 07:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:27:00 UTC to 2016-09-10 07:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:47:00 UTC to 2016-09-10 07:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:07:00 UTC to 2016-09-10 08:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:27:00 UTC to 2016-09-10 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:47:00 UTC to 2016-09-10 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:07:00 UTC to 2016-09-10 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:27:00 UTC to 2016-09-10 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:47:00 UTC to 2016-09-10 09:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:07:00 UTC to 2016-09-10 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:27:00 UTC to 2016-09-10 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:47:00 UTC to 2016-09-10 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:06:59 UTC to 2016-09-10 11:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:26:59 UTC to 2016-09-10 11:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:47:00 UTC to 2016-09-10 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:06:59 UTC to 2016-09-10 12:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:26:59 UTC to 2016-09-10 12:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:46:59 UTC to 2016-09-10 12:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:06:59 UTC to 2016-09-10 13:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:26:59 UTC to 2016-09-10 13:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:46:59 UTC to 2016-09-10 13:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:06:59 UTC to 2016-09-10 14:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:26:59 UTC to 2016-09-10 14:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:46:59 UTC to 2016-09-10 14:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:06:59 UTC to 2016-09-10 15:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:26:59 UTC to 2016-09-10 15:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:46:59 UTC to 2016-09-10 15:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:06:59 UTC to 2016-09-10 16:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:26:59 UTC to 2016-09-10 16:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:46:59 UTC to 2016-09-10 16:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:06:59 UTC to 2016-09-10 17:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:26:59 UTC to 2016-09-10 17:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:46:59 UTC to 2016-09-10 17:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:06:59 UTC to 2016-09-10 18:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:26:59 UTC to 2016-09-10 18:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:46:59 UTC to 2016-09-10 18:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:06:59 UTC to 2016-09-10 19:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:26:59 UTC to 2016-09-10 19:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:46:59 UTC to 2016-09-10 19:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:06:59 UTC to 2016-09-10 20:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:26:59 UTC to 2016-09-10 20:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:46:59 UTC to 2016-09-10 20:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:06:59 UTC to 2016-09-10 21:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:26:59 UTC to 2016-09-10 21:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:46:59 UTC to 2016-09-10 21:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:06:59 UTC to 2016-09-10 22:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:26:59 UTC to 2016-09-10 22:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:46:59 UTC to 2016-09-10 22:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:06:59 UTC to 2016-09-10 23:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:26:59 UTC to 2016-09-10 23:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:46:59 UTC to 2016-09-10 23:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:06:59 UTC to 2016-09-11 00:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:26:59 UTC to 2016-09-11 00:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:46:59 UTC to 2016-09-11 00:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:06:59 UTC to 2016-09-11 01:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:26:59 UTC to 2016-09-11 01:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:46:59 UTC to 2016-09-11 01:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:06:59 UTC to 2016-09-11 02:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:26:59 UTC to 2016-09-11 02:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:46:59 UTC to 2016-09-11 02:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:06:59 UTC to 2016-09-11 03:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:26:59 UTC to 2016-09-11 03:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:46:59 UTC to 2016-09-11 03:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:06:59 UTC to 2016-09-11 04:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:26:59 UTC to 2016-09-11 04:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:46:59 UTC to 2016-09-11 04:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:06:59 UTC to 2016-09-11 05:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:26:59 UTC to 2016-09-11 05:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:46:59 UTC to 2016-09-11 05:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:06:59 UTC to 2016-09-11 06:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:26:59 UTC to 2016-09-11 06:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:46:59 UTC to 2016-09-11 06:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:06:59 UTC to 2016-09-11 07:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:26:59 UTC to 2016-09-11 07:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:46:59 UTC to 2016-09-11 07:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:06:59 UTC to 2016-09-11 08:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:26:59 UTC to 2016-09-11 08:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:46:59 UTC to 2016-09-11 08:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 09:06:59 UTC to 2016-09-11 09:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 09:26:59 UTC to 2016-09-11 09:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:03:42 UTC to 2016-09-11 23:04:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:13:42 UTC to 2016-09-11 23:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:33:42 UTC to 2016-09-11 23:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:53:42 UTC to 2016-09-11 23:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:13:42 UTC to 2016-09-12 00:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:33:42 UTC to 2016-09-12 00:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:53:42 UTC to 2016-09-12 00:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:13:42 UTC to 2016-09-12 01:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:33:42 UTC to 2016-09-12 01:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:53:42 UTC to 2016-09-12 01:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:13:42 UTC to 2016-09-12 02:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:33:42 UTC to 2016-09-12 02:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:53:42 UTC to 2016-09-12 02:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:13:42 UTC to 2016-09-12 03:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:33:42 UTC to 2016-09-12 03:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:53:42 UTC to 2016-09-12 03:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:13:42 UTC to 2016-09-12 04:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:33:42 UTC to 2016-09-12 04:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:53:42 UTC to 2016-09-12 04:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:13:42 UTC to 2016-09-12 05:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:33:42 UTC to 2016-09-12 05:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:53:42 UTC to 2016-09-12 05:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:13:42 UTC to 2016-09-12 06:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:33:42 UTC to 2016-09-12 06:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:53:42 UTC to 2016-09-12 06:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:13:42 UTC to 2016-09-12 07:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:33:42 UTC to 2016-09-12 07:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:53:42 UTC to 2016-09-12 07:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:13:42 UTC to 2016-09-12 08:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:33:42 UTC to 2016-09-12 08:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:53:42 UTC to 2016-09-12 08:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:13:42 UTC to 2016-09-12 09:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:33:42 UTC to 2016-09-12 09:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:53:42 UTC to 2016-09-12 09:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:13:42 UTC to 2016-09-12 10:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:33:42 UTC to 2016-09-12 10:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:53:42 UTC to 2016-09-12 10:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:13:42 UTC to 2016-09-12 11:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:33:42 UTC to 2016-09-12 11:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:53:42 UTC to 2016-09-12 11:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:13:42 UTC to 2016-09-12 12:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:33:42 UTC to 2016-09-12 12:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:53:42 UTC to 2016-09-12 12:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:13:42 UTC to 2016-09-12 13:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:33:42 UTC to 2016-09-12 13:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:53:45 UTC to 2016-09-12 13:54:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:13:42 UTC to 2016-09-12 14:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:33:42 UTC to 2016-09-12 14:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:53:42 UTC to 2016-09-12 14:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:13:42 UTC to 2016-09-12 15:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:33:42 UTC to 2016-09-12 15:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:53:42 UTC to 2016-09-12 15:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:13:42 UTC to 2016-09-12 16:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:33:42 UTC to 2016-09-12 16:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:53:42 UTC to 2016-09-12 16:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:13:42 UTC to 2016-09-12 17:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:33:42 UTC to 2016-09-12 17:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:53:42 UTC to 2016-09-12 17:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:13:42 UTC to 2016-09-12 18:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:33:42 UTC to 2016-09-12 18:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:53:42 UTC to 2016-09-12 18:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:13:42 UTC to 2016-09-12 19:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:33:42 UTC to 2016-09-12 19:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:53:42 UTC to 2016-09-12 19:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:13:42 UTC to 2016-09-12 20:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:33:42 UTC to 2016-09-12 20:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:53:42 UTC to 2016-09-12 20:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:13:42 UTC to 2016-09-12 21:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:33:42 UTC to 2016-09-12 21:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:53:43 UTC to 2016-09-12 21:54:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:13:42 UTC to 2016-09-12 22:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:33:42 UTC to 2016-09-12 22:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:53:42 UTC to 2016-09-12 22:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:13:42 UTC to 2016-09-12 23:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:33:42 UTC to 2016-09-12 23:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:53:42 UTC to 2016-09-12 23:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:13:42 UTC to 2016-09-13 00:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:33:42 UTC to 2016-09-13 00:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:53:42 UTC to 2016-09-13 00:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:13:41 UTC to 2016-09-13 01:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:33:41 UTC to 2016-09-13 01:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:53:41 UTC to 2016-09-13 01:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:13:41 UTC to 2016-09-13 02:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:33:41 UTC to 2016-09-13 02:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:53:41 UTC to 2016-09-13 02:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:13:41 UTC to 2016-09-13 03:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:33:41 UTC to 2016-09-13 03:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:53:41 UTC to 2016-09-13 03:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:13:41 UTC to 2016-09-13 04:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:33:41 UTC to 2016-09-13 04:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:53:41 UTC to 2016-09-13 04:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:13:41 UTC to 2016-09-13 05:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:33:41 UTC to 2016-09-13 05:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:53:41 UTC to 2016-09-13 05:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:13:41 UTC to 2016-09-13 06:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:33:41 UTC to 2016-09-13 06:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:53:41 UTC to 2016-09-13 06:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:13:41 UTC to 2016-09-13 07:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:33:41 UTC to 2016-09-13 07:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:53:41 UTC to 2016-09-13 07:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:13:41 UTC to 2016-09-13 08:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:33:41 UTC to 2016-09-13 08:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:53:41 UTC to 2016-09-13 08:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:13:41 UTC to 2016-09-13 09:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:33:41 UTC to 2016-09-13 09:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:53:41 UTC to 2016-09-13 09:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:13:41 UTC to 2016-09-13 10:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:33:41 UTC to 2016-09-13 10:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:53:41 UTC to 2016-09-13 10:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:13:41 UTC to 2016-09-13 11:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:33:41 UTC to 2016-09-13 11:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:53:41 UTC to 2016-09-13 11:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:13:41 UTC to 2016-09-13 12:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:33:41 UTC to 2016-09-13 12:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:53:41 UTC to 2016-09-13 12:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:13:41 UTC to 2016-09-13 13:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:33:41 UTC to 2016-09-13 13:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:53:41 UTC to 2016-09-13 13:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:13:41 UTC to 2016-09-13 14:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:33:41 UTC to 2016-09-13 14:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:53:41 UTC to 2016-09-13 14:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:13:41 UTC to 2016-09-13 15:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:33:41 UTC to 2016-09-13 15:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:53:41 UTC to 2016-09-13 15:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:13:41 UTC to 2016-09-13 16:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:33:41 UTC to 2016-09-13 16:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:53:41 UTC to 2016-09-13 16:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:13:41 UTC to 2016-09-13 17:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:33:41 UTC to 2016-09-13 17:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:53:41 UTC to 2016-09-13 17:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:13:41 UTC to 2016-09-13 18:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:33:41 UTC to 2016-09-13 18:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:53:41 UTC to 2016-09-13 18:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:13:41 UTC to 2016-09-13 19:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:33:41 UTC to 2016-09-13 19:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:53:41 UTC to 2016-09-13 19:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:13:41 UTC to 2016-09-13 20:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:33:41 UTC to 2016-09-13 20:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:53:41 UTC to 2016-09-13 20:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:13:41 UTC to 2016-09-13 21:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:33:41 UTC to 2016-09-13 21:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:53:41 UTC to 2016-09-13 21:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:13:41 UTC to 2016-09-13 22:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:33:41 UTC to 2016-09-13 22:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:53:41 UTC to 2016-09-13 22:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:13:41 UTC to 2016-09-13 23:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:33:41 UTC to 2016-09-13 23:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:53:41 UTC to 2016-09-13 23:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:13:41 UTC to 2016-09-14 00:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:33:41 UTC to 2016-09-14 00:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:53:41 UTC to 2016-09-14 00:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:13:41 UTC to 2016-09-14 01:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:33:41 UTC to 2016-09-14 01:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:53:41 UTC to 2016-09-14 01:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:13:41 UTC to 2016-09-14 02:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:33:41 UTC to 2016-09-14 02:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:53:40 UTC to 2016-09-14 02:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:13:40 UTC to 2016-09-14 03:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:33:40 UTC to 2016-09-14 03:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:53:40 UTC to 2016-09-14 03:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:13:40 UTC to 2016-09-14 04:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:33:40 UTC to 2016-09-14 04:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:53:40 UTC to 2016-09-14 04:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:13:40 UTC to 2016-09-14 05:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:33:40 UTC to 2016-09-14 05:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:53:40 UTC to 2016-09-14 05:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:13:40 UTC to 2016-09-14 06:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:33:40 UTC to 2016-09-14 06:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:53:40 UTC to 2016-09-14 06:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:13:40 UTC to 2016-09-14 07:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:33:40 UTC to 2016-09-14 07:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:53:40 UTC to 2016-09-14 07:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:13:40 UTC to 2016-09-14 08:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:33:40 UTC to 2016-09-14 08:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:53:40 UTC to 2016-09-14 08:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:13:40 UTC to 2016-09-14 09:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:33:40 UTC to 2016-09-14 09:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:53:40 UTC to 2016-09-14 09:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:13:47 UTC to 2016-09-14 10:14:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:33:40 UTC to 2016-09-14 10:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:53:40 UTC to 2016-09-14 10:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:13:40 UTC to 2016-09-14 11:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:33:40 UTC to 2016-09-14 11:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:53:40 UTC to 2016-09-14 11:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:13:40 UTC to 2016-09-14 12:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:33:40 UTC to 2016-09-14 12:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:53:40 UTC to 2016-09-14 12:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:13:40 UTC to 2016-09-14 13:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:33:40 UTC to 2016-09-14 13:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:53:40 UTC to 2016-09-14 13:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:13:40 UTC to 2016-09-14 14:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:33:40 UTC to 2016-09-14 14:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:53:40 UTC to 2016-09-14 14:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:13:40 UTC to 2016-09-14 15:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:33:40 UTC to 2016-09-14 15:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:53:40 UTC to 2016-09-14 15:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:13:40 UTC to 2016-09-14 16:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:33:40 UTC to 2016-09-14 16:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:53:40 UTC to 2016-09-14 16:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:13:40 UTC to 2016-09-14 17:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:33:40 UTC to 2016-09-14 17:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:53:40 UTC to 2016-09-14 17:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:13:40 UTC to 2016-09-14 18:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:33:40 UTC to 2016-09-14 18:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:53:40 UTC to 2016-09-14 18:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:13:40 UTC to 2016-09-14 19:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:33:40 UTC to 2016-09-14 19:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:53:40 UTC to 2016-09-14 19:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:13:40 UTC to 2016-09-14 20:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:33:40 UTC to 2016-09-14 20:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:53:40 UTC to 2016-09-14 20:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:13:40 UTC to 2016-09-14 21:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:33:40 UTC to 2016-09-14 21:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:53:40 UTC to 2016-09-14 21:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:13:40 UTC to 2016-09-14 22:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:33:40 UTC to 2016-09-14 22:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:53:40 UTC to 2016-09-14 22:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:13:40 UTC to 2016-09-14 23:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:33:40 UTC to 2016-09-14 23:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:53:40 UTC to 2016-09-14 23:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:13:40 UTC to 2016-09-15 00:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:33:40 UTC to 2016-09-15 00:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:53:40 UTC to 2016-09-15 00:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:13:40 UTC to 2016-09-15 01:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:33:40 UTC to 2016-09-15 01:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:53:40 UTC to 2016-09-15 01:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:13:40 UTC to 2016-09-15 02:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:33:40 UTC to 2016-09-15 02:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:53:40 UTC to 2016-09-15 02:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:13:40 UTC to 2016-09-15 03:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:33:40 UTC to 2016-09-15 03:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:53:40 UTC to 2016-09-15 03:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:13:40 UTC to 2016-09-15 04:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:33:40 UTC to 2016-09-15 04:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:53:40 UTC to 2016-09-15 04:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:13:40 UTC to 2016-09-15 05:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:33:39 UTC to 2016-09-15 05:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:53:40 UTC to 2016-09-15 05:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:13:40 UTC to 2016-09-15 06:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:33:40 UTC to 2016-09-15 06:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:53:40 UTC to 2016-09-15 06:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:13:40 UTC to 2016-09-15 07:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:33:39 UTC to 2016-09-15 07:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:53:39 UTC to 2016-09-15 07:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:13:39 UTC to 2016-09-15 08:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:33:39 UTC to 2016-09-15 08:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:53:39 UTC to 2016-09-15 08:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:13:39 UTC to 2016-09-15 09:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:33:39 UTC to 2016-09-15 09:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:53:39 UTC to 2016-09-15 09:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:13:39 UTC to 2016-09-15 10:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:33:39 UTC to 2016-09-15 10:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:53:39 UTC to 2016-09-15 10:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:13:39 UTC to 2016-09-15 11:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:33:39 UTC to 2016-09-15 11:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:53:39 UTC to 2016-09-15 11:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:13:39 UTC to 2016-09-15 12:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:33:39 UTC to 2016-09-15 12:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:53:39 UTC to 2016-09-15 12:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:13:39 UTC to 2016-09-15 13:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:33:39 UTC to 2016-09-15 13:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:53:39 UTC to 2016-09-15 13:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:13:39 UTC to 2016-09-15 14:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:33:39 UTC to 2016-09-15 14:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:53:39 UTC to 2016-09-15 14:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:13:39 UTC to 2016-09-15 15:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:33:39 UTC to 2016-09-15 15:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:53:39 UTC to 2016-09-15 15:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:13:39 UTC to 2016-09-15 16:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:33:39 UTC to 2016-09-15 16:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:53:39 UTC to 2016-09-15 16:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:13:39 UTC to 2016-09-15 17:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:33:39 UTC to 2016-09-15 17:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:53:39 UTC to 2016-09-15 17:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:13:39 UTC to 2016-09-15 18:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:33:39 UTC to 2016-09-15 18:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:53:39 UTC to 2016-09-15 18:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:13:39 UTC to 2016-09-15 19:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:33:39 UTC to 2016-09-15 19:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:53:39 UTC to 2016-09-15 19:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:13:39 UTC to 2016-09-15 20:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:33:39 UTC to 2016-09-15 20:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:53:39 UTC to 2016-09-15 20:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:13:39 UTC to 2016-09-15 21:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:33:39 UTC to 2016-09-15 21:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:53:39 UTC to 2016-09-15 21:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:13:39 UTC to 2016-09-15 22:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:33:39 UTC to 2016-09-15 22:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:53:39 UTC to 2016-09-15 22:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:13:39 UTC to 2016-09-15 23:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:33:39 UTC to 2016-09-15 23:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:53:39 UTC to 2016-09-15 23:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:13:39 UTC to 2016-09-16 00:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:33:39 UTC to 2016-09-16 00:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:53:39 UTC to 2016-09-16 00:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:13:39 UTC to 2016-09-16 01:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:33:39 UTC to 2016-09-16 01:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:53:39 UTC to 2016-09-16 01:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:13:39 UTC to 2016-09-16 02:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:33:39 UTC to 2016-09-16 02:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:53:39 UTC to 2016-09-16 02:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:13:39 UTC to 2016-09-16 03:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:33:39 UTC to 2016-09-16 03:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:53:39 UTC to 2016-09-16 03:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:13:39 UTC to 2016-09-16 04:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:33:39 UTC to 2016-09-16 04:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:53:39 UTC to 2016-09-16 04:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:13:39 UTC to 2016-09-16 05:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:33:39 UTC to 2016-09-16 05:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:53:39 UTC to 2016-09-16 05:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:13:39 UTC to 2016-09-16 06:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:33:39 UTC to 2016-09-16 06:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:53:39 UTC to 2016-09-16 06:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:13:39 UTC to 2016-09-16 07:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:33:39 UTC to 2016-09-16 07:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:53:39 UTC to 2016-09-16 07:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:13:39 UTC to 2016-09-16 08:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:33:39 UTC to 2016-09-16 08:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:53:39 UTC to 2016-09-16 08:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:13:39 UTC to 2016-09-16 09:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:33:38 UTC to 2016-09-16 09:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:53:39 UTC to 2016-09-16 09:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:13:38 UTC to 2016-09-16 10:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:33:38 UTC to 2016-09-16 10:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:53:38 UTC to 2016-09-16 10:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:13:38 UTC to 2016-09-16 11:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:33:38 UTC to 2016-09-16 11:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:53:38 UTC to 2016-09-16 11:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:13:38 UTC to 2016-09-16 12:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:33:38 UTC to 2016-09-16 12:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:53:38 UTC to 2016-09-16 12:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 19:55:13 UTC to 2016-09-18 19:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:15:13 UTC to 2016-09-18 20:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:35:13 UTC to 2016-09-18 20:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:55:13 UTC to 2016-09-18 20:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:15:13 UTC to 2016-09-18 21:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:35:13 UTC to 2016-09-18 21:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:55:13 UTC to 2016-09-18 21:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:15:13 UTC to 2016-09-18 22:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:35:13 UTC to 2016-09-18 22:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:55:13 UTC to 2016-09-18 22:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:15:13 UTC to 2016-09-18 23:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:35:13 UTC to 2016-09-18 23:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:55:13 UTC to 2016-09-18 23:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:15:13 UTC to 2016-09-19 00:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:35:13 UTC to 2016-09-19 00:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:55:13 UTC to 2016-09-19 00:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:15:13 UTC to 2016-09-19 01:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:35:13 UTC to 2016-09-19 01:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:55:13 UTC to 2016-09-19 01:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:15:13 UTC to 2016-09-19 02:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:35:13 UTC to 2016-09-19 02:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:55:13 UTC to 2016-09-19 02:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:15:13 UTC to 2016-09-19 03:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:35:13 UTC to 2016-09-19 03:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:55:13 UTC to 2016-09-19 03:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:15:13 UTC to 2016-09-19 04:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:35:13 UTC to 2016-09-19 04:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:55:13 UTC to 2016-09-19 04:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:15:13 UTC to 2016-09-19 05:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:35:13 UTC to 2016-09-19 05:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:55:13 UTC to 2016-09-19 05:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:15:13 UTC to 2016-09-19 06:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:35:13 UTC to 2016-09-19 06:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:55:13 UTC to 2016-09-19 06:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:15:13 UTC to 2016-09-19 07:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:35:13 UTC to 2016-09-19 07:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:55:13 UTC to 2016-09-19 07:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:15:13 UTC to 2016-09-19 08:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:35:13 UTC to 2016-09-19 08:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:55:12 UTC to 2016-09-19 08:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:15:13 UTC to 2016-09-19 09:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:35:12 UTC to 2016-09-19 09:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:55:12 UTC to 2016-09-19 09:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:15:13 UTC to 2016-09-19 10:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:35:12 UTC to 2016-09-19 10:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:55:12 UTC to 2016-09-19 10:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:15:12 UTC to 2016-09-19 11:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:35:12 UTC to 2016-09-19 11:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:55:30 UTC to 2016-09-19 11:55:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:15:30 UTC to 2016-09-19 12:15:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:37:25 UTC to 2016-09-19 12:37:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:59:09 UTC to 2016-09-19 12:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:20:42 UTC to 2016-09-19 13:21:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:45:52 UTC to 2016-09-19 13:46:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:58:06 UTC to 2016-09-19 13:58:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:15:12 UTC to 2016-09-19 14:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:35:12 UTC to 2016-09-19 14:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:55:12 UTC to 2016-09-19 14:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:15:12 UTC to 2016-09-19 15:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:35:12 UTC to 2016-09-19 15:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:55:12 UTC to 2016-09-19 15:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:15:12 UTC to 2016-09-19 16:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:35:12 UTC to 2016-09-19 16:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:55:12 UTC to 2016-09-19 16:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:15:12 UTC to 2016-09-19 17:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:35:12 UTC to 2016-09-19 17:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:55:12 UTC to 2016-09-19 17:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:15:12 UTC to 2016-09-19 18:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:35:12 UTC to 2016-09-19 18:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:55:12 UTC to 2016-09-19 18:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:15:12 UTC to 2016-09-19 19:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:35:12 UTC to 2016-09-19 19:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:55:12 UTC to 2016-09-19 19:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:15:12 UTC to 2016-09-19 20:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:35:12 UTC to 2016-09-19 20:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:55:12 UTC to 2016-09-19 20:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:15:12 UTC to 2016-09-19 21:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:35:12 UTC to 2016-09-19 21:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:55:12 UTC to 2016-09-19 21:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:15:12 UTC to 2016-09-19 22:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:35:12 UTC to 2016-09-19 22:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:55:12 UTC to 2016-09-19 22:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:15:12 UTC to 2016-09-19 23:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:35:12 UTC to 2016-09-19 23:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:55:12 UTC to 2016-09-19 23:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:15:12 UTC to 2016-09-20 00:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:35:12 UTC to 2016-09-20 00:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:55:12 UTC to 2016-09-20 00:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:15:12 UTC to 2016-09-20 01:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:35:12 UTC to 2016-09-20 01:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:55:12 UTC to 2016-09-20 01:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:15:12 UTC to 2016-09-20 02:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:35:12 UTC to 2016-09-20 02:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:55:12 UTC to 2016-09-20 02:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:15:12 UTC to 2016-09-20 03:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:35:12 UTC to 2016-09-20 03:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:55:12 UTC to 2016-09-20 03:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:15:12 UTC to 2016-09-20 04:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:35:12 UTC to 2016-09-20 04:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:55:12 UTC to 2016-09-20 04:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:15:12 UTC to 2016-09-20 05:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:35:12 UTC to 2016-09-20 05:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:55:12 UTC to 2016-09-20 05:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:15:12 UTC to 2016-09-20 06:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:35:12 UTC to 2016-09-20 06:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:55:12 UTC to 2016-09-20 06:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:15:12 UTC to 2016-09-20 07:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:35:12 UTC to 2016-09-20 07:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:55:12 UTC to 2016-09-20 07:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:15:12 UTC to 2016-09-20 08:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:35:12 UTC to 2016-09-20 08:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:55:12 UTC to 2016-09-20 08:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:15:12 UTC to 2016-09-20 09:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:35:12 UTC to 2016-09-20 09:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:55:12 UTC to 2016-09-20 09:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:15:12 UTC to 2016-09-20 10:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:35:12 UTC to 2016-09-20 10:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:55:12 UTC to 2016-09-20 10:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:15:12 UTC to 2016-09-20 11:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:35:12 UTC to 2016-09-20 11:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:55:11 UTC to 2016-09-20 11:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:15:11 UTC to 2016-09-20 12:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:35:11 UTC to 2016-09-20 12:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:55:11 UTC to 2016-09-20 12:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:15:12 UTC to 2016-09-20 13:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:35:12 UTC to 2016-09-20 13:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:55:12 UTC to 2016-09-20 13:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:15:11 UTC to 2016-09-20 14:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:35:12 UTC to 2016-09-20 14:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:55:11 UTC to 2016-09-20 14:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:15:11 UTC to 2016-09-20 15:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:35:11 UTC to 2016-09-20 15:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:55:11 UTC to 2016-09-20 15:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:15:11 UTC to 2016-09-20 16:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:35:11 UTC to 2016-09-20 16:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:55:11 UTC to 2016-09-20 16:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:15:11 UTC to 2016-09-20 17:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:35:11 UTC to 2016-09-20 17:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:55:11 UTC to 2016-09-20 17:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:15:11 UTC to 2016-09-20 18:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:35:11 UTC to 2016-09-20 18:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:55:11 UTC to 2016-09-20 18:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:15:11 UTC to 2016-09-20 19:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:35:11 UTC to 2016-09-20 19:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:55:11 UTC to 2016-09-20 19:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:15:11 UTC to 2016-09-20 20:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:35:11 UTC to 2016-09-20 20:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:55:11 UTC to 2016-09-20 20:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:15:11 UTC to 2016-09-20 21:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:35:11 UTC to 2016-09-20 21:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:55:11 UTC to 2016-09-20 21:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:15:11 UTC to 2016-09-20 22:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:35:11 UTC to 2016-09-20 22:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:55:11 UTC to 2016-09-20 22:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:15:11 UTC to 2016-09-20 23:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:35:11 UTC to 2016-09-20 23:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:55:11 UTC to 2016-09-20 23:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:15:11 UTC to 2016-09-21 00:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:35:11 UTC to 2016-09-21 00:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:55:11 UTC to 2016-09-21 00:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:15:11 UTC to 2016-09-21 01:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:35:11 UTC to 2016-09-21 01:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:55:11 UTC to 2016-09-21 01:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:15:11 UTC to 2016-09-21 02:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:35:11 UTC to 2016-09-21 02:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:55:11 UTC to 2016-09-21 02:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:15:11 UTC to 2016-09-21 03:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:35:11 UTC to 2016-09-21 03:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:55:11 UTC to 2016-09-21 03:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:15:11 UTC to 2016-09-21 04:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:35:11 UTC to 2016-09-21 04:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:55:11 UTC to 2016-09-21 04:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:15:11 UTC to 2016-09-21 05:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:35:11 UTC to 2016-09-21 05:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:55:11 UTC to 2016-09-21 05:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:15:11 UTC to 2016-09-21 06:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:35:11 UTC to 2016-09-21 06:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:55:11 UTC to 2016-09-21 06:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:15:11 UTC to 2016-09-21 07:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:35:11 UTC to 2016-09-21 07:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:55:11 UTC to 2016-09-21 07:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:15:11 UTC to 2016-09-21 08:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:35:11 UTC to 2016-09-21 08:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:55:11 UTC to 2016-09-21 08:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:15:11 UTC to 2016-09-21 09:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:35:11 UTC to 2016-09-21 09:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:55:11 UTC to 2016-09-21 09:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:15:11 UTC to 2016-09-21 10:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:35:11 UTC to 2016-09-21 10:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:55:11 UTC to 2016-09-21 10:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:15:11 UTC to 2016-09-21 11:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:35:11 UTC to 2016-09-21 11:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:55:11 UTC to 2016-09-21 11:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:15:11 UTC to 2016-09-21 12:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:35:11 UTC to 2016-09-21 12:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:55:11 UTC to 2016-09-21 12:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:15:11 UTC to 2016-09-21 13:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:35:11 UTC to 2016-09-21 13:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:55:11 UTC to 2016-09-21 13:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:15:11 UTC to 2016-09-21 14:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:35:10 UTC to 2016-09-21 14:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:55:11 UTC to 2016-09-21 14:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:15:11 UTC to 2016-09-21 15:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:35:11 UTC to 2016-09-21 15:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:55:11 UTC to 2016-09-21 15:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:15:10 UTC to 2016-09-21 16:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:35:11 UTC to 2016-09-21 16:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:55:10 UTC to 2016-09-21 16:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:15:10 UTC to 2016-09-21 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:35:10 UTC to 2016-09-21 17:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:55:10 UTC to 2016-09-21 17:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:15:10 UTC to 2016-09-21 18:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:35:10 UTC to 2016-09-21 18:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:55:10 UTC to 2016-09-21 18:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:15:11 UTC to 2016-09-21 19:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:35:10 UTC to 2016-09-21 19:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:55:10 UTC to 2016-09-21 19:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:15:10 UTC to 2016-09-21 20:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:35:10 UTC to 2016-09-21 20:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:55:10 UTC to 2016-09-21 20:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:15:10 UTC to 2016-09-21 21:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:35:10 UTC to 2016-09-21 21:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:55:10 UTC to 2016-09-21 21:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:15:10 UTC to 2016-09-21 22:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:35:10 UTC to 2016-09-21 22:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:55:10 UTC to 2016-09-21 22:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:15:10 UTC to 2016-09-21 23:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:35:10 UTC to 2016-09-21 23:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:55:10 UTC to 2016-09-21 23:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:15:10 UTC to 2016-09-22 00:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:35:10 UTC to 2016-09-22 00:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:55:10 UTC to 2016-09-22 00:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:15:10 UTC to 2016-09-22 01:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:35:10 UTC to 2016-09-22 01:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:55:10 UTC to 2016-09-22 01:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:15:10 UTC to 2016-09-22 02:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:35:10 UTC to 2016-09-22 02:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:55:10 UTC to 2016-09-22 02:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:15:10 UTC to 2016-09-22 03:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:35:10 UTC to 2016-09-22 03:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:55:10 UTC to 2016-09-22 03:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:15:10 UTC to 2016-09-22 04:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:35:10 UTC to 2016-09-22 04:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:55:10 UTC to 2016-09-22 04:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:15:10 UTC to 2016-09-22 05:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:35:10 UTC to 2016-09-22 05:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:55:10 UTC to 2016-09-22 05:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:15:10 UTC to 2016-09-22 06:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:35:10 UTC to 2016-09-22 06:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:55:10 UTC to 2016-09-22 06:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:15:10 UTC to 2016-09-22 07:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:35:10 UTC to 2016-09-22 07:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:55:10 UTC to 2016-09-22 07:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:15:10 UTC to 2016-09-22 08:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:35:10 UTC to 2016-09-22 08:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:55:10 UTC to 2016-09-22 08:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:15:10 UTC to 2016-09-22 09:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:35:10 UTC to 2016-09-22 09:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:55:10 UTC to 2016-09-22 09:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:15:10 UTC to 2016-09-22 10:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:35:10 UTC to 2016-09-22 10:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:55:10 UTC to 2016-09-22 10:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:15:10 UTC to 2016-09-22 11:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:35:10 UTC to 2016-09-22 11:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:55:10 UTC to 2016-09-22 11:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:15:10 UTC to 2016-09-22 12:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:35:10 UTC to 2016-09-22 12:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:55:10 UTC to 2016-09-22 12:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:15:10 UTC to 2016-09-22 13:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:35:10 UTC to 2016-09-22 13:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:55:10 UTC to 2016-09-22 13:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:15:10 UTC to 2016-09-22 14:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:35:10 UTC to 2016-09-22 14:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:55:10 UTC to 2016-09-22 14:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:15:10 UTC to 2016-09-22 15:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:35:10 UTC to 2016-09-22 15:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:55:10 UTC to 2016-09-22 15:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:15:10 UTC to 2016-09-22 16:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:35:10 UTC to 2016-09-22 16:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:55:09 UTC to 2016-09-22 16:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:15:10 UTC to 2016-09-22 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:35:10 UTC to 2016-09-22 17:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:55:10 UTC to 2016-09-22 17:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:15:09 UTC to 2016-09-22 18:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:35:09 UTC to 2016-09-22 18:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:55:09 UTC to 2016-09-22 18:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:15:09 UTC to 2016-09-22 19:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:35:09 UTC to 2016-09-22 19:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:55:09 UTC to 2016-09-22 19:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:15:09 UTC to 2016-09-22 20:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:35:09 UTC to 2016-09-22 20:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:55:09 UTC to 2016-09-22 20:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:15:10 UTC to 2016-09-22 21:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:35:09 UTC to 2016-09-22 21:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:55:09 UTC to 2016-09-22 21:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:15:09 UTC to 2016-09-22 22:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:35:09 UTC to 2016-09-22 22:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:55:09 UTC to 2016-09-22 22:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:15:09 UTC to 2016-09-22 23:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:35:09 UTC to 2016-09-22 23:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:55:09 UTC to 2016-09-22 23:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:15:09 UTC to 2016-09-23 00:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:35:09 UTC to 2016-09-23 00:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:55:09 UTC to 2016-09-23 00:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:15:09 UTC to 2016-09-23 01:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:35:09 UTC to 2016-09-23 01:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:55:09 UTC to 2016-09-23 01:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:15:09 UTC to 2016-09-23 02:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:35:09 UTC to 2016-09-23 02:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:55:09 UTC to 2016-09-23 02:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:15:09 UTC to 2016-09-23 03:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:35:09 UTC to 2016-09-23 03:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:55:09 UTC to 2016-09-23 03:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:15:09 UTC to 2016-09-23 04:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:35:09 UTC to 2016-09-23 04:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:55:09 UTC to 2016-09-23 04:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:15:09 UTC to 2016-09-23 05:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:35:09 UTC to 2016-09-23 05:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:55:09 UTC to 2016-09-23 05:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 15:36:14 UTC to 2016-09-24 15:36:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 15:46:14 UTC to 2016-09-24 15:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:06:14 UTC to 2016-09-24 16:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:26:14 UTC to 2016-09-24 16:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:46:14 UTC to 2016-09-24 16:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:06:14 UTC to 2016-09-24 17:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:26:14 UTC to 2016-09-24 17:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:46:14 UTC to 2016-09-24 17:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:06:14 UTC to 2016-09-24 18:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:26:14 UTC to 2016-09-24 18:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:46:14 UTC to 2016-09-24 18:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:06:14 UTC to 2016-09-24 19:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:26:14 UTC to 2016-09-24 19:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:46:14 UTC to 2016-09-24 19:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:06:14 UTC to 2016-09-24 20:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:26:14 UTC to 2016-09-24 20:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:46:14 UTC to 2016-09-24 20:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:06:14 UTC to 2016-09-24 21:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:26:14 UTC to 2016-09-24 21:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:46:14 UTC to 2016-09-24 21:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:06:14 UTC to 2016-09-24 22:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:26:14 UTC to 2016-09-24 22:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:46:14 UTC to 2016-09-24 22:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:06:14 UTC to 2016-09-24 23:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:26:14 UTC to 2016-09-24 23:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:46:14 UTC to 2016-09-24 23:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:06:14 UTC to 2016-09-25 00:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:26:14 UTC to 2016-09-25 00:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:46:14 UTC to 2016-09-25 00:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:06:14 UTC to 2016-09-25 01:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:26:14 UTC to 2016-09-25 01:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:46:14 UTC to 2016-09-25 01:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:06:14 UTC to 2016-09-25 02:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:26:14 UTC to 2016-09-25 02:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:46:14 UTC to 2016-09-25 02:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:06:14 UTC to 2016-09-25 03:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:26:14 UTC to 2016-09-25 03:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:46:14 UTC to 2016-09-25 03:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:06:14 UTC to 2016-09-25 04:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:26:14 UTC to 2016-09-25 04:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:46:14 UTC to 2016-09-25 04:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:06:14 UTC to 2016-09-25 05:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:26:14 UTC to 2016-09-25 05:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:46:14 UTC to 2016-09-25 05:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:06:14 UTC to 2016-09-25 06:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:26:14 UTC to 2016-09-25 06:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:46:14 UTC to 2016-09-25 06:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:06:14 UTC to 2016-09-25 07:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:26:14 UTC to 2016-09-25 07:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:46:14 UTC to 2016-09-25 07:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:06:14 UTC to 2016-09-25 08:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:26:14 UTC to 2016-09-25 08:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:46:14 UTC to 2016-09-25 08:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:06:14 UTC to 2016-09-25 09:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:26:14 UTC to 2016-09-25 09:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:46:13 UTC to 2016-09-25 09:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:06:14 UTC to 2016-09-25 10:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:26:13 UTC to 2016-09-25 10:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:46:14 UTC to 2016-09-25 10:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:06:13 UTC to 2016-09-25 11:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:26:14 UTC to 2016-09-25 11:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:46:13 UTC to 2016-09-25 11:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:06:13 UTC to 2016-09-25 12:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:26:13 UTC to 2016-09-25 12:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:46:13 UTC to 2016-09-25 12:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:06:14 UTC to 2016-09-25 13:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:26:13 UTC to 2016-09-25 13:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:46:13 UTC to 2016-09-25 13:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:06:13 UTC to 2016-09-25 14:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:26:13 UTC to 2016-09-25 14:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:46:13 UTC to 2016-09-25 14:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:06:13 UTC to 2016-09-25 15:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:26:13 UTC to 2016-09-25 15:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:46:13 UTC to 2016-09-25 15:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:06:13 UTC to 2016-09-25 16:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:26:13 UTC to 2016-09-25 16:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:46:13 UTC to 2016-09-25 16:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:06:13 UTC to 2016-09-25 17:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:26:13 UTC to 2016-09-25 17:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:46:13 UTC to 2016-09-25 17:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:06:13 UTC to 2016-09-25 18:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:26:13 UTC to 2016-09-25 18:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:46:13 UTC to 2016-09-25 18:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:06:13 UTC to 2016-09-25 19:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:26:13 UTC to 2016-09-25 19:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:46:13 UTC to 2016-09-25 19:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:06:13 UTC to 2016-09-25 20:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:26:13 UTC to 2016-09-25 20:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:46:13 UTC to 2016-09-25 20:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:06:13 UTC to 2016-09-25 21:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:26:13 UTC to 2016-09-25 21:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:46:13 UTC to 2016-09-25 21:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:06:13 UTC to 2016-09-25 22:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:26:13 UTC to 2016-09-25 22:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:46:13 UTC to 2016-09-25 22:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:06:13 UTC to 2016-09-25 23:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:26:13 UTC to 2016-09-25 23:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:46:13 UTC to 2016-09-25 23:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:06:13 UTC to 2016-09-26 00:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:26:13 UTC to 2016-09-26 00:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:46:13 UTC to 2016-09-26 00:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:06:13 UTC to 2016-09-26 01:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:26:13 UTC to 2016-09-26 01:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:46:13 UTC to 2016-09-26 01:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:06:13 UTC to 2016-09-26 02:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:26:13 UTC to 2016-09-26 02:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:46:13 UTC to 2016-09-26 02:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:06:13 UTC to 2016-09-26 03:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:26:13 UTC to 2016-09-26 03:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:46:13 UTC to 2016-09-26 03:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:06:13 UTC to 2016-09-26 04:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:26:13 UTC to 2016-09-26 04:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:46:13 UTC to 2016-09-26 04:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:06:13 UTC to 2016-09-26 05:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:26:13 UTC to 2016-09-26 05:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:46:13 UTC to 2016-09-26 05:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:06:13 UTC to 2016-09-26 06:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:26:13 UTC to 2016-09-26 06:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:46:13 UTC to 2016-09-26 06:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:06:13 UTC to 2016-09-26 07:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:26:13 UTC to 2016-09-26 07:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:46:13 UTC to 2016-09-26 07:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:06:13 UTC to 2016-09-26 08:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:26:13 UTC to 2016-09-26 08:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:46:13 UTC to 2016-09-26 08:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:06:13 UTC to 2016-09-26 09:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:26:13 UTC to 2016-09-26 09:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:46:13 UTC to 2016-09-26 09:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:06:13 UTC to 2016-09-26 10:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:26:13 UTC to 2016-09-26 10:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:46:13 UTC to 2016-09-26 10:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:06:13 UTC to 2016-09-26 11:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:26:13 UTC to 2016-09-26 11:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:46:13 UTC to 2016-09-26 11:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:06:13 UTC to 2016-09-26 12:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:26:13 UTC to 2016-09-26 12:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:46:13 UTC to 2016-09-26 12:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:06:13 UTC to 2016-09-26 13:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:26:12 UTC to 2016-09-26 13:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:46:13 UTC to 2016-09-26 13:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:06:13 UTC to 2016-09-26 14:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:26:12 UTC to 2016-09-26 14:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:46:12 UTC to 2016-09-26 14:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:06:12 UTC to 2016-09-26 15:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:26:12 UTC to 2016-09-26 15:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:46:12 UTC to 2016-09-26 15:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:06:12 UTC to 2016-09-26 16:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:26:13 UTC to 2016-09-26 16:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:46:12 UTC to 2016-09-26 16:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:06:12 UTC to 2016-09-26 17:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:26:12 UTC to 2016-09-26 17:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:46:12 UTC to 2016-09-26 17:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:06:12 UTC to 2016-09-26 18:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:26:12 UTC to 2016-09-26 18:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:46:12 UTC to 2016-09-26 18:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:06:12 UTC to 2016-09-26 19:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:26:12 UTC to 2016-09-26 19:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:46:12 UTC to 2016-09-26 19:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:06:12 UTC to 2016-09-26 20:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:26:12 UTC to 2016-09-26 20:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:46:12 UTC to 2016-09-26 20:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:06:12 UTC to 2016-09-26 21:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:26:12 UTC to 2016-09-26 21:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:46:12 UTC to 2016-09-26 21:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:06:12 UTC to 2016-09-26 22:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:26:12 UTC to 2016-09-26 22:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:46:12 UTC to 2016-09-26 22:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:06:12 UTC to 2016-09-26 23:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:26:12 UTC to 2016-09-26 23:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:46:12 UTC to 2016-09-26 23:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:06:12 UTC to 2016-09-27 00:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:26:12 UTC to 2016-09-27 00:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:46:12 UTC to 2016-09-27 00:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:06:12 UTC to 2016-09-27 01:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:26:12 UTC to 2016-09-27 01:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:46:12 UTC to 2016-09-27 01:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:06:12 UTC to 2016-09-27 02:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:26:12 UTC to 2016-09-27 02:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:46:12 UTC to 2016-09-27 02:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:06:12 UTC to 2016-09-27 03:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:26:12 UTC to 2016-09-27 03:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:46:12 UTC to 2016-09-27 03:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:06:12 UTC to 2016-09-27 04:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:26:12 UTC to 2016-09-27 04:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:46:12 UTC to 2016-09-27 04:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:06:12 UTC to 2016-09-27 05:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:26:12 UTC to 2016-09-27 05:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:46:12 UTC to 2016-09-27 05:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:06:12 UTC to 2016-09-27 06:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:26:12 UTC to 2016-09-27 06:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:46:12 UTC to 2016-09-27 06:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:06:12 UTC to 2016-09-27 07:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:26:12 UTC to 2016-09-27 07:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:46:12 UTC to 2016-09-27 07:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:06:12 UTC to 2016-09-27 08:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:26:12 UTC to 2016-09-27 08:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:46:12 UTC to 2016-09-27 08:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:06:12 UTC to 2016-09-27 09:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:26:12 UTC to 2016-09-27 09:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:46:12 UTC to 2016-09-27 09:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 10:06:12 UTC to 2016-09-27 10:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:07:15 UTC to 2016-09-27 22:07:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:17:15 UTC to 2016-09-27 22:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:37:15 UTC to 2016-09-27 22:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:57:15 UTC to 2016-09-27 22:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:17:15 UTC to 2016-09-27 23:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:37:15 UTC to 2016-09-27 23:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:57:15 UTC to 2016-09-27 23:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:17:15 UTC to 2016-09-28 00:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:37:15 UTC to 2016-09-28 00:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:57:15 UTC to 2016-09-28 00:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:17:15 UTC to 2016-09-28 01:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:37:15 UTC to 2016-09-28 01:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:57:15 UTC to 2016-09-28 01:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:17:15 UTC to 2016-09-28 02:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:37:15 UTC to 2016-09-28 02:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:57:15 UTC to 2016-09-28 02:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:17:15 UTC to 2016-09-28 03:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:37:19 UTC to 2016-09-28 03:37:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:57:15 UTC to 2016-09-28 03:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:17:15 UTC to 2016-09-28 04:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:37:15 UTC to 2016-09-28 04:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:57:15 UTC to 2016-09-28 04:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:17:15 UTC to 2016-09-28 05:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:37:15 UTC to 2016-09-28 05:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:57:14 UTC to 2016-09-28 05:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:17:14 UTC to 2016-09-28 06:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:37:14 UTC to 2016-09-28 06:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:57:21 UTC to 2016-09-28 06:57:41 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:17:14 UTC to 2016-09-28 07:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:37:15 UTC to 2016-09-28 07:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:57:14 UTC to 2016-09-28 07:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:17:14 UTC to 2016-09-28 08:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:37:14 UTC to 2016-09-28 08:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:57:14 UTC to 2016-09-28 08:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:17:14 UTC to 2016-09-28 09:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:37:14 UTC to 2016-09-28 09:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:57:14 UTC to 2016-09-28 09:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:17:14 UTC to 2016-09-28 10:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:37:14 UTC to 2016-09-28 10:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:57:14 UTC to 2016-09-28 10:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:17:14 UTC to 2016-09-28 11:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:37:14 UTC to 2016-09-28 11:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:57:14 UTC to 2016-09-28 11:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:17:14 UTC to 2016-09-28 12:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:37:14 UTC to 2016-09-28 12:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:57:14 UTC to 2016-09-28 12:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:17:14 UTC to 2016-09-28 13:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:37:14 UTC to 2016-09-28 13:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:57:14 UTC to 2016-09-28 13:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:17:14 UTC to 2016-09-28 14:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:37:14 UTC to 2016-09-28 14:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:57:14 UTC to 2016-09-28 14:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:17:14 UTC to 2016-09-28 15:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:37:14 UTC to 2016-09-28 15:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:57:14 UTC to 2016-09-28 15:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:17:14 UTC to 2016-09-28 16:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:37:14 UTC to 2016-09-28 16:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:57:14 UTC to 2016-09-28 16:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:17:14 UTC to 2016-09-28 17:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:37:14 UTC to 2016-09-28 17:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:57:14 UTC to 2016-09-28 17:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:17:14 UTC to 2016-09-28 18:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:37:14 UTC to 2016-09-28 18:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:57:14 UTC to 2016-09-28 18:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:17:14 UTC to 2016-09-28 19:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:37:14 UTC to 2016-09-28 19:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:57:14 UTC to 2016-09-28 19:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:17:14 UTC to 2016-09-28 20:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:37:14 UTC to 2016-09-28 20:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:57:14 UTC to 2016-09-28 20:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:17:14 UTC to 2016-09-28 21:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:37:14 UTC to 2016-09-28 21:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:57:14 UTC to 2016-09-28 21:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:17:14 UTC to 2016-09-28 22:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:37:14 UTC to 2016-09-28 22:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:57:14 UTC to 2016-09-28 22:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:17:14 UTC to 2016-09-28 23:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:37:14 UTC to 2016-09-28 23:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:57:14 UTC to 2016-09-28 23:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:17:14 UTC to 2016-09-29 00:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:37:14 UTC to 2016-09-29 00:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:57:14 UTC to 2016-09-29 00:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:17:14 UTC to 2016-09-29 01:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:37:14 UTC to 2016-09-29 01:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:57:14 UTC to 2016-09-29 01:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:17:14 UTC to 2016-09-29 02:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:37:14 UTC to 2016-09-29 02:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:57:14 UTC to 2016-09-29 02:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:17:14 UTC to 2016-09-29 03:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:37:14 UTC to 2016-09-29 03:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:57:14 UTC to 2016-09-29 03:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:17:14 UTC to 2016-09-29 04:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:37:14 UTC to 2016-09-29 04:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:57:14 UTC to 2016-09-29 04:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:17:14 UTC to 2016-09-29 05:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:37:14 UTC to 2016-09-29 05:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:57:14 UTC to 2016-09-29 05:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:17:14 UTC to 2016-09-29 06:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:37:14 UTC to 2016-09-29 06:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:57:14 UTC to 2016-09-29 06:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:17:14 UTC to 2016-09-29 07:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:37:14 UTC to 2016-09-29 07:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:57:14 UTC to 2016-09-29 07:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:17:14 UTC to 2016-09-29 08:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:37:14 UTC to 2016-09-29 08:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:57:14 UTC to 2016-09-29 08:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:17:14 UTC to 2016-09-29 09:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:37:13 UTC to 2016-09-29 09:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:57:13 UTC to 2016-09-29 09:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:17:13 UTC to 2016-09-29 10:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:37:13 UTC to 2016-09-29 10:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:57:13 UTC to 2016-09-29 10:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:17:13 UTC to 2016-09-29 11:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:37:13 UTC to 2016-09-29 11:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:57:13 UTC to 2016-09-29 11:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:17:13 UTC to 2016-09-29 12:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:37:13 UTC to 2016-09-29 12:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:57:13 UTC to 2016-09-29 12:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:17:13 UTC to 2016-09-29 13:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:37:13 UTC to 2016-09-29 13:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:57:13 UTC to 2016-09-29 13:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:17:13 UTC to 2016-09-29 14:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:37:13 UTC to 2016-09-29 14:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:57:13 UTC to 2016-09-29 14:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:17:15 UTC to 2016-09-29 15:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:37:13 UTC to 2016-09-29 15:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:57:13 UTC to 2016-09-29 15:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:17:13 UTC to 2016-09-29 16:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:37:13 UTC to 2016-09-29 16:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:57:13 UTC to 2016-09-29 16:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:17:13 UTC to 2016-09-29 17:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:37:13 UTC to 2016-09-29 17:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:57:13 UTC to 2016-09-29 17:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:17:13 UTC to 2016-09-29 18:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:37:13 UTC to 2016-09-29 18:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:57:13 UTC to 2016-09-29 18:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:17:13 UTC to 2016-09-29 19:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:37:13 UTC to 2016-09-29 19:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:57:13 UTC to 2016-09-29 19:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:17:13 UTC to 2016-09-29 20:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:37:13 UTC to 2016-09-29 20:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:57:13 UTC to 2016-09-29 20:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:17:13 UTC to 2016-09-29 21:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:37:13 UTC to 2016-09-29 21:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:57:13 UTC to 2016-09-29 21:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:17:13 UTC to 2016-09-29 22:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:37:13 UTC to 2016-09-29 22:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:57:13 UTC to 2016-09-29 22:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:17:13 UTC to 2016-09-29 23:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:37:13 UTC to 2016-09-29 23:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:57:13 UTC to 2016-09-29 23:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:17:13 UTC to 2016-09-30 00:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:37:13 UTC to 2016-09-30 00:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:57:13 UTC to 2016-09-30 00:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:17:13 UTC to 2016-09-30 01:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:37:13 UTC to 2016-09-30 01:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:57:13 UTC to 2016-09-30 01:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:17:13 UTC to 2016-09-30 02:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:37:13 UTC to 2016-09-30 02:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:57:13 UTC to 2016-09-30 02:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:17:13 UTC to 2016-09-30 03:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:37:13 UTC to 2016-09-30 03:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:57:13 UTC to 2016-09-30 03:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:17:13 UTC to 2016-09-30 04:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:37:13 UTC to 2016-09-30 04:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:57:13 UTC to 2016-09-30 04:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:17:13 UTC to 2016-09-30 05:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:37:13 UTC to 2016-09-30 05:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:57:13 UTC to 2016-09-30 05:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:17:13 UTC to 2016-09-30 06:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:37:13 UTC to 2016-09-30 06:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:57:13 UTC to 2016-09-30 06:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:17:13 UTC to 2016-09-30 07:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:37:13 UTC to 2016-09-30 07:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:57:13 UTC to 2016-09-30 07:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:17:13 UTC to 2016-09-30 08:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:37:13 UTC to 2016-09-30 08:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:57:13 UTC to 2016-09-30 08:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:17:13 UTC to 2016-09-30 09:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:37:13 UTC to 2016-09-30 09:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:57:13 UTC to 2016-09-30 09:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:17:13 UTC to 2016-09-30 10:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:37:13 UTC to 2016-09-30 10:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:57:13 UTC to 2016-09-30 10:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:17:13 UTC to 2016-09-30 11:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:37:13 UTC to 2016-09-30 11:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:57:13 UTC to 2016-09-30 11:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:17:12 UTC to 2016-09-30 12:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:37:13 UTC to 2016-09-30 12:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:57:13 UTC to 2016-09-30 12:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:17:12 UTC to 2016-09-30 13:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:37:12 UTC to 2016-09-30 13:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:57:12 UTC to 2016-09-30 13:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:17:12 UTC to 2016-09-30 14:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:37:12 UTC to 2016-09-30 14:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:57:12 UTC to 2016-09-30 14:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:17:12 UTC to 2016-09-30 15:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:37:12 UTC to 2016-09-30 15:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:57:12 UTC to 2016-09-30 15:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:17:12 UTC to 2016-09-30 16:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:37:12 UTC to 2016-09-30 16:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:57:12 UTC to 2016-09-30 16:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:17:12 UTC to 2016-09-30 17:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:37:12 UTC to 2016-09-30 17:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:57:12 UTC to 2016-09-30 17:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:17:12 UTC to 2016-09-30 18:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:37:12 UTC to 2016-09-30 18:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:57:12 UTC to 2016-09-30 18:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:17:12 UTC to 2016-09-30 19:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:37:12 UTC to 2016-09-30 19:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:57:12 UTC to 2016-09-30 19:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:17:12 UTC to 2016-09-30 20:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:37:12 UTC to 2016-09-30 20:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:57:12 UTC to 2016-09-30 20:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:17:12 UTC to 2016-09-30 21:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:37:12 UTC to 2016-09-30 21:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:57:12 UTC to 2016-09-30 21:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:17:12 UTC to 2016-09-30 22:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:37:12 UTC to 2016-09-30 22:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:57:12 UTC to 2016-09-30 22:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:17:12 UTC to 2016-09-30 23:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:37:12 UTC to 2016-09-30 23:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:57:12 UTC to 2016-09-30 23:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:17:12 UTC to 2016-10-01 00:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:37:12 UTC to 2016-10-01 00:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:57:12 UTC to 2016-10-01 00:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:17:12 UTC to 2016-10-01 01:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:37:12 UTC to 2016-10-01 01:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:57:12 UTC to 2016-10-01 01:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:17:12 UTC to 2016-10-01 02:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:37:12 UTC to 2016-10-01 02:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:57:12 UTC to 2016-10-01 02:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:17:12 UTC to 2016-10-01 03:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:37:12 UTC to 2016-10-01 03:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:57:12 UTC to 2016-10-01 03:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:17:12 UTC to 2016-10-01 04:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:37:12 UTC to 2016-10-01 04:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:57:12 UTC to 2016-10-01 04:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:17:12 UTC to 2016-10-01 05:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:37:12 UTC to 2016-10-01 05:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:57:12 UTC to 2016-10-01 05:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:17:12 UTC to 2016-10-01 06:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:37:12 UTC to 2016-10-01 06:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:57:12 UTC to 2016-10-01 06:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:17:12 UTC to 2016-10-01 07:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:37:12 UTC to 2016-10-01 07:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:57:12 UTC to 2016-10-01 07:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:09:16 UTC to 2016-09-02 22:09:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:19:16 UTC to 2016-09-02 22:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:39:16 UTC to 2016-09-02 22:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 22:59:16 UTC to 2016-09-02 22:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:19:16 UTC to 2016-09-02 23:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:39:16 UTC to 2016-09-02 23:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-02 23:59:16 UTC to 2016-09-02 23:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:19:16 UTC to 2016-09-03 00:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:39:16 UTC to 2016-09-03 00:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 00:59:16 UTC to 2016-09-03 00:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:19:16 UTC to 2016-09-03 01:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:39:16 UTC to 2016-09-03 01:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 01:59:16 UTC to 2016-09-03 01:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:19:16 UTC to 2016-09-03 02:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:39:16 UTC to 2016-09-03 02:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 02:59:16 UTC to 2016-09-03 02:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:19:16 UTC to 2016-09-03 03:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:39:16 UTC to 2016-09-03 03:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 03:59:16 UTC to 2016-09-03 03:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:19:16 UTC to 2016-09-03 04:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:39:16 UTC to 2016-09-03 04:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 04:59:16 UTC to 2016-09-03 04:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:19:16 UTC to 2016-09-03 05:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:39:16 UTC to 2016-09-03 05:39:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 05:59:16 UTC to 2016-09-03 05:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:19:16 UTC to 2016-09-03 06:19:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:39:15 UTC to 2016-09-03 06:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 06:59:15 UTC to 2016-09-03 06:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:19:15 UTC to 2016-09-03 07:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:39:15 UTC to 2016-09-03 07:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 07:59:16 UTC to 2016-09-03 07:59:36 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:19:15 UTC to 2016-09-03 08:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:39:15 UTC to 2016-09-03 08:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 08:59:15 UTC to 2016-09-03 08:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:19:15 UTC to 2016-09-03 09:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:39:15 UTC to 2016-09-03 09:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 09:59:15 UTC to 2016-09-03 09:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:19:15 UTC to 2016-09-03 10:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:39:15 UTC to 2016-09-03 10:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 10:59:15 UTC to 2016-09-03 10:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:19:15 UTC to 2016-09-03 11:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:39:15 UTC to 2016-09-03 11:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 11:59:15 UTC to 2016-09-03 11:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:19:15 UTC to 2016-09-03 12:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:39:15 UTC to 2016-09-03 12:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 12:59:15 UTC to 2016-09-03 12:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:19:15 UTC to 2016-09-03 13:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:39:15 UTC to 2016-09-03 13:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 13:59:15 UTC to 2016-09-03 13:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:19:15 UTC to 2016-09-03 14:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:39:15 UTC to 2016-09-03 14:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 14:59:15 UTC to 2016-09-03 14:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:19:15 UTC to 2016-09-03 15:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:39:15 UTC to 2016-09-03 15:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 15:59:15 UTC to 2016-09-03 15:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:19:15 UTC to 2016-09-03 16:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:39:15 UTC to 2016-09-03 16:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 16:59:15 UTC to 2016-09-03 16:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:19:15 UTC to 2016-09-03 17:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:39:15 UTC to 2016-09-03 17:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 17:59:15 UTC to 2016-09-03 17:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:19:15 UTC to 2016-09-03 18:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:39:15 UTC to 2016-09-03 18:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 18:59:15 UTC to 2016-09-03 18:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:19:15 UTC to 2016-09-03 19:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:39:15 UTC to 2016-09-03 19:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 19:59:15 UTC to 2016-09-03 19:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:19:15 UTC to 2016-09-03 20:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:39:15 UTC to 2016-09-03 20:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 20:59:15 UTC to 2016-09-03 20:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:19:15 UTC to 2016-09-03 21:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:39:15 UTC to 2016-09-03 21:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 21:59:15 UTC to 2016-09-03 21:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:19:15 UTC to 2016-09-03 22:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:39:15 UTC to 2016-09-03 22:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 22:59:15 UTC to 2016-09-03 22:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:19:15 UTC to 2016-09-03 23:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:39:15 UTC to 2016-09-03 23:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-03 23:59:15 UTC to 2016-09-03 23:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:19:15 UTC to 2016-09-04 00:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:39:15 UTC to 2016-09-04 00:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 00:59:15 UTC to 2016-09-04 00:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:19:15 UTC to 2016-09-04 01:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:39:15 UTC to 2016-09-04 01:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 01:59:15 UTC to 2016-09-04 01:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:19:15 UTC to 2016-09-04 02:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:39:15 UTC to 2016-09-04 02:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 02:59:15 UTC to 2016-09-04 02:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:19:15 UTC to 2016-09-04 03:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:39:15 UTC to 2016-09-04 03:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 03:59:15 UTC to 2016-09-04 03:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:19:15 UTC to 2016-09-04 04:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:39:15 UTC to 2016-09-04 04:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 04:59:15 UTC to 2016-09-04 04:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:19:15 UTC to 2016-09-04 05:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:39:15 UTC to 2016-09-04 05:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 05:59:15 UTC to 2016-09-04 05:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:19:15 UTC to 2016-09-04 06:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:39:15 UTC to 2016-09-04 06:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 06:59:15 UTC to 2016-09-04 06:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:19:15 UTC to 2016-09-04 07:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:39:15 UTC to 2016-09-04 07:39:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 07:59:15 UTC to 2016-09-04 07:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:19:14 UTC to 2016-09-04 08:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:39:14 UTC to 2016-09-04 08:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 08:59:15 UTC to 2016-09-04 08:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:19:15 UTC to 2016-09-04 09:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:39:14 UTC to 2016-09-04 09:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 09:59:15 UTC to 2016-09-04 09:59:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:19:14 UTC to 2016-09-04 10:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:39:14 UTC to 2016-09-04 10:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 10:59:14 UTC to 2016-09-04 10:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:19:15 UTC to 2016-09-04 11:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:39:14 UTC to 2016-09-04 11:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 11:59:14 UTC to 2016-09-04 11:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:19:14 UTC to 2016-09-04 12:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:39:14 UTC to 2016-09-04 12:39:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 12:59:14 UTC to 2016-09-04 12:59:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 13:19:14 UTC to 2016-09-04 13:19:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 23:22:35 UTC to 2016-09-04 23:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-04 23:42:35 UTC to 2016-09-04 23:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:02:35 UTC to 2016-09-05 00:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:22:35 UTC to 2016-09-05 00:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 00:42:35 UTC to 2016-09-05 00:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:02:35 UTC to 2016-09-05 01:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:22:35 UTC to 2016-09-05 01:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 01:42:35 UTC to 2016-09-05 01:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:02:35 UTC to 2016-09-05 02:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:22:35 UTC to 2016-09-05 02:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 02:42:35 UTC to 2016-09-05 02:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:02:35 UTC to 2016-09-05 03:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:22:35 UTC to 2016-09-05 03:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 03:42:35 UTC to 2016-09-05 03:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:02:35 UTC to 2016-09-05 04:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:22:35 UTC to 2016-09-05 04:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 04:42:35 UTC to 2016-09-05 04:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:02:35 UTC to 2016-09-05 05:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:22:35 UTC to 2016-09-05 05:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 05:42:35 UTC to 2016-09-05 05:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:02:35 UTC to 2016-09-05 06:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:22:35 UTC to 2016-09-05 06:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 06:42:35 UTC to 2016-09-05 06:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:02:35 UTC to 2016-09-05 07:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:22:35 UTC to 2016-09-05 07:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 07:42:35 UTC to 2016-09-05 07:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:02:35 UTC to 2016-09-05 08:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:22:35 UTC to 2016-09-05 08:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 08:42:35 UTC to 2016-09-05 08:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:02:35 UTC to 2016-09-05 09:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:22:35 UTC to 2016-09-05 09:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 09:42:35 UTC to 2016-09-05 09:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:02:35 UTC to 2016-09-05 10:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:22:35 UTC to 2016-09-05 10:22:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 10:42:35 UTC to 2016-09-05 10:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:02:35 UTC to 2016-09-05 11:02:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:22:34 UTC to 2016-09-05 11:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 11:42:35 UTC to 2016-09-05 11:42:55 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:02:34 UTC to 2016-09-05 12:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:22:34 UTC to 2016-09-05 12:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 12:42:34 UTC to 2016-09-05 12:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:02:34 UTC to 2016-09-05 13:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:22:34 UTC to 2016-09-05 13:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 13:42:34 UTC to 2016-09-05 13:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:02:34 UTC to 2016-09-05 14:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:22:34 UTC to 2016-09-05 14:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 14:42:34 UTC to 2016-09-05 14:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:02:34 UTC to 2016-09-05 15:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:22:34 UTC to 2016-09-05 15:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 15:42:34 UTC to 2016-09-05 15:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:02:34 UTC to 2016-09-05 16:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:22:34 UTC to 2016-09-05 16:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 16:42:34 UTC to 2016-09-05 16:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:02:34 UTC to 2016-09-05 17:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:22:34 UTC to 2016-09-05 17:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 17:42:34 UTC to 2016-09-05 17:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:02:34 UTC to 2016-09-05 18:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:22:34 UTC to 2016-09-05 18:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 18:42:34 UTC to 2016-09-05 18:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:02:34 UTC to 2016-09-05 19:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:22:34 UTC to 2016-09-05 19:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 19:42:34 UTC to 2016-09-05 19:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:02:34 UTC to 2016-09-05 20:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:22:34 UTC to 2016-09-05 20:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 20:42:34 UTC to 2016-09-05 20:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:02:34 UTC to 2016-09-05 21:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:22:34 UTC to 2016-09-05 21:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 21:42:34 UTC to 2016-09-05 21:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:02:34 UTC to 2016-09-05 22:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:22:34 UTC to 2016-09-05 22:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 22:42:34 UTC to 2016-09-05 22:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:02:34 UTC to 2016-09-05 23:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:22:34 UTC to 2016-09-05 23:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-05 23:42:34 UTC to 2016-09-05 23:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:02:34 UTC to 2016-09-06 00:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:22:34 UTC to 2016-09-06 00:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 00:42:34 UTC to 2016-09-06 00:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:02:34 UTC to 2016-09-06 01:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:22:34 UTC to 2016-09-06 01:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 01:42:34 UTC to 2016-09-06 01:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:02:34 UTC to 2016-09-06 02:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:22:34 UTC to 2016-09-06 02:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 02:42:34 UTC to 2016-09-06 02:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:02:34 UTC to 2016-09-06 03:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:22:34 UTC to 2016-09-06 03:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 03:42:34 UTC to 2016-09-06 03:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:02:34 UTC to 2016-09-06 04:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:22:34 UTC to 2016-09-06 04:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 04:42:34 UTC to 2016-09-06 04:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:02:34 UTC to 2016-09-06 05:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:22:34 UTC to 2016-09-06 05:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 05:42:34 UTC to 2016-09-06 05:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:02:34 UTC to 2016-09-06 06:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:22:34 UTC to 2016-09-06 06:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 06:42:34 UTC to 2016-09-06 06:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:02:34 UTC to 2016-09-06 07:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:22:34 UTC to 2016-09-06 07:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 07:42:34 UTC to 2016-09-06 07:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:02:34 UTC to 2016-09-06 08:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:22:34 UTC to 2016-09-06 08:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 08:42:34 UTC to 2016-09-06 08:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:02:34 UTC to 2016-09-06 09:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:22:34 UTC to 2016-09-06 09:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 09:42:34 UTC to 2016-09-06 09:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:02:34 UTC to 2016-09-06 10:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:22:34 UTC to 2016-09-06 10:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 10:42:34 UTC to 2016-09-06 10:42:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 11:02:34 UTC to 2016-09-06 11:02:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-06 11:22:34 UTC to 2016-09-06 11:22:54 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:17:02 UTC to 2016-09-07 16:17:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:27:02 UTC to 2016-09-07 16:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 16:47:02 UTC to 2016-09-07 16:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:07:02 UTC to 2016-09-07 17:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:27:02 UTC to 2016-09-07 17:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 17:47:02 UTC to 2016-09-07 17:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:07:11 UTC to 2016-09-07 18:07:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:27:02 UTC to 2016-09-07 18:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 18:47:02 UTC to 2016-09-07 18:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:07:02 UTC to 2016-09-07 19:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:27:02 UTC to 2016-09-07 19:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 19:47:02 UTC to 2016-09-07 19:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:07:02 UTC to 2016-09-07 20:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:27:02 UTC to 2016-09-07 20:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 20:47:02 UTC to 2016-09-07 20:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:07:02 UTC to 2016-09-07 21:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:27:02 UTC to 2016-09-07 21:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 21:47:02 UTC to 2016-09-07 21:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:07:02 UTC to 2016-09-07 22:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:27:02 UTC to 2016-09-07 22:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 22:47:02 UTC to 2016-09-07 22:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:07:02 UTC to 2016-09-07 23:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:27:02 UTC to 2016-09-07 23:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-07 23:47:02 UTC to 2016-09-07 23:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:07:02 UTC to 2016-09-08 00:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:27:02 UTC to 2016-09-08 00:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 00:47:02 UTC to 2016-09-08 00:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:07:02 UTC to 2016-09-08 01:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:27:02 UTC to 2016-09-08 01:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 01:47:02 UTC to 2016-09-08 01:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:07:02 UTC to 2016-09-08 02:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:27:02 UTC to 2016-09-08 02:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 02:47:02 UTC to 2016-09-08 02:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:07:02 UTC to 2016-09-08 03:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:27:02 UTC to 2016-09-08 03:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 03:47:02 UTC to 2016-09-08 03:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:07:02 UTC to 2016-09-08 04:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:27:02 UTC to 2016-09-08 04:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 04:47:02 UTC to 2016-09-08 04:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:07:02 UTC to 2016-09-08 05:07:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:27:02 UTC to 2016-09-08 05:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 05:47:02 UTC to 2016-09-08 05:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:07:01 UTC to 2016-09-08 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:27:02 UTC to 2016-09-08 06:27:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 06:47:02 UTC to 2016-09-08 06:47:22 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:07:01 UTC to 2016-09-08 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:27:01 UTC to 2016-09-08 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 07:47:01 UTC to 2016-09-08 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:07:01 UTC to 2016-09-08 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:27:01 UTC to 2016-09-08 08:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 08:47:01 UTC to 2016-09-08 08:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:07:01 UTC to 2016-09-08 09:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:27:01 UTC to 2016-09-08 09:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 09:47:01 UTC to 2016-09-08 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:07:01 UTC to 2016-09-08 10:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:27:01 UTC to 2016-09-08 10:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 10:47:01 UTC to 2016-09-08 10:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:07:01 UTC to 2016-09-08 11:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:27:01 UTC to 2016-09-08 11:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 11:47:01 UTC to 2016-09-08 11:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:07:01 UTC to 2016-09-08 12:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:27:01 UTC to 2016-09-08 12:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 12:47:01 UTC to 2016-09-08 12:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:07:01 UTC to 2016-09-08 13:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:27:01 UTC to 2016-09-08 13:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 13:47:01 UTC to 2016-09-08 13:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:07:01 UTC to 2016-09-08 14:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:27:01 UTC to 2016-09-08 14:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 14:47:01 UTC to 2016-09-08 14:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:07:01 UTC to 2016-09-08 15:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:27:01 UTC to 2016-09-08 15:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 15:47:01 UTC to 2016-09-08 15:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:07:01 UTC to 2016-09-08 16:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:27:01 UTC to 2016-09-08 16:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 16:47:01 UTC to 2016-09-08 16:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:07:01 UTC to 2016-09-08 17:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:27:01 UTC to 2016-09-08 17:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 17:47:01 UTC to 2016-09-08 17:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:07:01 UTC to 2016-09-08 18:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:27:01 UTC to 2016-09-08 18:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 18:47:01 UTC to 2016-09-08 18:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:07:01 UTC to 2016-09-08 19:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:27:01 UTC to 2016-09-08 19:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 19:47:01 UTC to 2016-09-08 19:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:07:01 UTC to 2016-09-08 20:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:27:01 UTC to 2016-09-08 20:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 20:47:01 UTC to 2016-09-08 20:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:07:01 UTC to 2016-09-08 21:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:27:01 UTC to 2016-09-08 21:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 21:47:01 UTC to 2016-09-08 21:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:07:01 UTC to 2016-09-08 22:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:27:01 UTC to 2016-09-08 22:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 22:47:01 UTC to 2016-09-08 22:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:07:01 UTC to 2016-09-08 23:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:27:01 UTC to 2016-09-08 23:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-08 23:47:01 UTC to 2016-09-08 23:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:07:01 UTC to 2016-09-09 00:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:27:01 UTC to 2016-09-09 00:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 00:47:01 UTC to 2016-09-09 00:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:07:01 UTC to 2016-09-09 01:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:27:01 UTC to 2016-09-09 01:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 01:47:01 UTC to 2016-09-09 01:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:07:01 UTC to 2016-09-09 02:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:27:01 UTC to 2016-09-09 02:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 02:47:01 UTC to 2016-09-09 02:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:07:01 UTC to 2016-09-09 03:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:27:01 UTC to 2016-09-09 03:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 03:47:01 UTC to 2016-09-09 03:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:07:01 UTC to 2016-09-09 04:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:27:01 UTC to 2016-09-09 04:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 04:47:01 UTC to 2016-09-09 04:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:07:01 UTC to 2016-09-09 05:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:27:01 UTC to 2016-09-09 05:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 05:47:01 UTC to 2016-09-09 05:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:07:01 UTC to 2016-09-09 06:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:27:01 UTC to 2016-09-09 06:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 06:47:01 UTC to 2016-09-09 06:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:07:01 UTC to 2016-09-09 07:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:27:01 UTC to 2016-09-09 07:27:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 07:47:01 UTC to 2016-09-09 07:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:07:01 UTC to 2016-09-09 08:07:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:27:00 UTC to 2016-09-09 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 08:47:00 UTC to 2016-09-09 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:07:00 UTC to 2016-09-09 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:27:00 UTC to 2016-09-09 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 09:47:01 UTC to 2016-09-09 09:47:21 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:07:00 UTC to 2016-09-09 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:27:00 UTC to 2016-09-09 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 10:47:00 UTC to 2016-09-09 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:07:00 UTC to 2016-09-09 11:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:27:00 UTC to 2016-09-09 11:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 11:47:00 UTC to 2016-09-09 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:07:00 UTC to 2016-09-09 12:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:27:00 UTC to 2016-09-09 12:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 12:47:00 UTC to 2016-09-09 12:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:07:00 UTC to 2016-09-09 13:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:27:00 UTC to 2016-09-09 13:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 13:47:00 UTC to 2016-09-09 13:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:07:00 UTC to 2016-09-09 14:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:27:00 UTC to 2016-09-09 14:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 14:47:00 UTC to 2016-09-09 14:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:07:00 UTC to 2016-09-09 15:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:27:00 UTC to 2016-09-09 15:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 15:47:00 UTC to 2016-09-09 15:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:07:00 UTC to 2016-09-09 16:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:27:00 UTC to 2016-09-09 16:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 16:47:00 UTC to 2016-09-09 16:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:07:00 UTC to 2016-09-09 17:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:27:00 UTC to 2016-09-09 17:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 17:47:00 UTC to 2016-09-09 17:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:07:00 UTC to 2016-09-09 18:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:27:00 UTC to 2016-09-09 18:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 18:47:00 UTC to 2016-09-09 18:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:07:00 UTC to 2016-09-09 19:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:27:00 UTC to 2016-09-09 19:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 19:47:00 UTC to 2016-09-09 19:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:07:00 UTC to 2016-09-09 20:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:27:00 UTC to 2016-09-09 20:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 20:47:00 UTC to 2016-09-09 20:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:07:00 UTC to 2016-09-09 21:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:27:00 UTC to 2016-09-09 21:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 21:47:00 UTC to 2016-09-09 21:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:07:00 UTC to 2016-09-09 22:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:27:00 UTC to 2016-09-09 22:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 22:47:00 UTC to 2016-09-09 22:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:07:00 UTC to 2016-09-09 23:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:27:00 UTC to 2016-09-09 23:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-09 23:47:00 UTC to 2016-09-09 23:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:07:00 UTC to 2016-09-10 00:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:27:00 UTC to 2016-09-10 00:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 00:47:00 UTC to 2016-09-10 00:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:07:00 UTC to 2016-09-10 01:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:27:00 UTC to 2016-09-10 01:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 01:47:00 UTC to 2016-09-10 01:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:07:00 UTC to 2016-09-10 02:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:27:00 UTC to 2016-09-10 02:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 02:47:00 UTC to 2016-09-10 02:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:07:00 UTC to 2016-09-10 03:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:27:00 UTC to 2016-09-10 03:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 03:47:00 UTC to 2016-09-10 03:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:07:00 UTC to 2016-09-10 04:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:27:00 UTC to 2016-09-10 04:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 04:47:00 UTC to 2016-09-10 04:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:07:00 UTC to 2016-09-10 05:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:27:00 UTC to 2016-09-10 05:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 05:47:00 UTC to 2016-09-10 05:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:07:00 UTC to 2016-09-10 06:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:27:00 UTC to 2016-09-10 06:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 06:47:00 UTC to 2016-09-10 06:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:07:00 UTC to 2016-09-10 07:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:27:00 UTC to 2016-09-10 07:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 07:47:00 UTC to 2016-09-10 07:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:07:00 UTC to 2016-09-10 08:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:27:00 UTC to 2016-09-10 08:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 08:47:00 UTC to 2016-09-10 08:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:07:00 UTC to 2016-09-10 09:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:27:00 UTC to 2016-09-10 09:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 09:47:00 UTC to 2016-09-10 09:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:07:00 UTC to 2016-09-10 10:07:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:27:00 UTC to 2016-09-10 10:27:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 10:47:00 UTC to 2016-09-10 10:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:06:59 UTC to 2016-09-10 11:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:26:59 UTC to 2016-09-10 11:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 11:47:00 UTC to 2016-09-10 11:47:20 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:06:59 UTC to 2016-09-10 12:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:26:59 UTC to 2016-09-10 12:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 12:46:59 UTC to 2016-09-10 12:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:06:59 UTC to 2016-09-10 13:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:26:59 UTC to 2016-09-10 13:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 13:46:59 UTC to 2016-09-10 13:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:06:59 UTC to 2016-09-10 14:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:26:59 UTC to 2016-09-10 14:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 14:46:59 UTC to 2016-09-10 14:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:06:59 UTC to 2016-09-10 15:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:26:59 UTC to 2016-09-10 15:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 15:46:59 UTC to 2016-09-10 15:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:06:59 UTC to 2016-09-10 16:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:26:59 UTC to 2016-09-10 16:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 16:46:59 UTC to 2016-09-10 16:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:06:59 UTC to 2016-09-10 17:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:26:59 UTC to 2016-09-10 17:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 17:46:59 UTC to 2016-09-10 17:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:06:59 UTC to 2016-09-10 18:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:26:59 UTC to 2016-09-10 18:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 18:46:59 UTC to 2016-09-10 18:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:06:59 UTC to 2016-09-10 19:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:26:59 UTC to 2016-09-10 19:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 19:46:59 UTC to 2016-09-10 19:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:06:59 UTC to 2016-09-10 20:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:26:59 UTC to 2016-09-10 20:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 20:46:59 UTC to 2016-09-10 20:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:06:59 UTC to 2016-09-10 21:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:26:59 UTC to 2016-09-10 21:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 21:46:59 UTC to 2016-09-10 21:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:06:59 UTC to 2016-09-10 22:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:26:59 UTC to 2016-09-10 22:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 22:46:59 UTC to 2016-09-10 22:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:06:59 UTC to 2016-09-10 23:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:26:59 UTC to 2016-09-10 23:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-10 23:46:59 UTC to 2016-09-10 23:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:06:59 UTC to 2016-09-11 00:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:26:59 UTC to 2016-09-11 00:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 00:46:59 UTC to 2016-09-11 00:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:06:59 UTC to 2016-09-11 01:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:26:59 UTC to 2016-09-11 01:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 01:46:59 UTC to 2016-09-11 01:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:06:59 UTC to 2016-09-11 02:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:26:59 UTC to 2016-09-11 02:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 02:46:59 UTC to 2016-09-11 02:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:06:59 UTC to 2016-09-11 03:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:26:59 UTC to 2016-09-11 03:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 03:46:59 UTC to 2016-09-11 03:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:06:59 UTC to 2016-09-11 04:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:26:59 UTC to 2016-09-11 04:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 04:46:59 UTC to 2016-09-11 04:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:06:59 UTC to 2016-09-11 05:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:26:59 UTC to 2016-09-11 05:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 05:46:59 UTC to 2016-09-11 05:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:06:59 UTC to 2016-09-11 06:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:26:59 UTC to 2016-09-11 06:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 06:46:59 UTC to 2016-09-11 06:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:06:59 UTC to 2016-09-11 07:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:26:59 UTC to 2016-09-11 07:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 07:46:59 UTC to 2016-09-11 07:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:06:59 UTC to 2016-09-11 08:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:26:59 UTC to 2016-09-11 08:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 08:46:59 UTC to 2016-09-11 08:47:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 09:06:59 UTC to 2016-09-11 09:07:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 09:26:59 UTC to 2016-09-11 09:27:19 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:03:42 UTC to 2016-09-11 23:04:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:13:42 UTC to 2016-09-11 23:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:33:42 UTC to 2016-09-11 23:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-11 23:53:42 UTC to 2016-09-11 23:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:13:42 UTC to 2016-09-12 00:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:33:42 UTC to 2016-09-12 00:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 00:53:42 UTC to 2016-09-12 00:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:13:42 UTC to 2016-09-12 01:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:33:42 UTC to 2016-09-12 01:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 01:53:42 UTC to 2016-09-12 01:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:13:42 UTC to 2016-09-12 02:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:33:42 UTC to 2016-09-12 02:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 02:53:42 UTC to 2016-09-12 02:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:13:42 UTC to 2016-09-12 03:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:33:42 UTC to 2016-09-12 03:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 03:53:42 UTC to 2016-09-12 03:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:13:42 UTC to 2016-09-12 04:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:33:42 UTC to 2016-09-12 04:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 04:53:42 UTC to 2016-09-12 04:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:13:42 UTC to 2016-09-12 05:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:33:42 UTC to 2016-09-12 05:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 05:53:42 UTC to 2016-09-12 05:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:13:42 UTC to 2016-09-12 06:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:33:42 UTC to 2016-09-12 06:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 06:53:42 UTC to 2016-09-12 06:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:13:42 UTC to 2016-09-12 07:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:33:42 UTC to 2016-09-12 07:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 07:53:42 UTC to 2016-09-12 07:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:13:42 UTC to 2016-09-12 08:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:33:42 UTC to 2016-09-12 08:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 08:53:42 UTC to 2016-09-12 08:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:13:42 UTC to 2016-09-12 09:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:33:42 UTC to 2016-09-12 09:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 09:53:42 UTC to 2016-09-12 09:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:13:42 UTC to 2016-09-12 10:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:33:42 UTC to 2016-09-12 10:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 10:53:42 UTC to 2016-09-12 10:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:13:42 UTC to 2016-09-12 11:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:33:42 UTC to 2016-09-12 11:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 11:53:42 UTC to 2016-09-12 11:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:13:42 UTC to 2016-09-12 12:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:33:42 UTC to 2016-09-12 12:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 12:53:42 UTC to 2016-09-12 12:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:13:42 UTC to 2016-09-12 13:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:33:42 UTC to 2016-09-12 13:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 13:53:45 UTC to 2016-09-12 13:54:05 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:13:42 UTC to 2016-09-12 14:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:33:42 UTC to 2016-09-12 14:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 14:53:42 UTC to 2016-09-12 14:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:13:42 UTC to 2016-09-12 15:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:33:42 UTC to 2016-09-12 15:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 15:53:42 UTC to 2016-09-12 15:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:13:42 UTC to 2016-09-12 16:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:33:42 UTC to 2016-09-12 16:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 16:53:42 UTC to 2016-09-12 16:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:13:42 UTC to 2016-09-12 17:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:33:42 UTC to 2016-09-12 17:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 17:53:42 UTC to 2016-09-12 17:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:13:42 UTC to 2016-09-12 18:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:33:42 UTC to 2016-09-12 18:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 18:53:42 UTC to 2016-09-12 18:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:13:42 UTC to 2016-09-12 19:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:33:42 UTC to 2016-09-12 19:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 19:53:42 UTC to 2016-09-12 19:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:13:42 UTC to 2016-09-12 20:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:33:42 UTC to 2016-09-12 20:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 20:53:42 UTC to 2016-09-12 20:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:13:42 UTC to 2016-09-12 21:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:33:42 UTC to 2016-09-12 21:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 21:53:43 UTC to 2016-09-12 21:54:03 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:13:42 UTC to 2016-09-12 22:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:33:42 UTC to 2016-09-12 22:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 22:53:42 UTC to 2016-09-12 22:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:13:42 UTC to 2016-09-12 23:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:33:42 UTC to 2016-09-12 23:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-12 23:53:42 UTC to 2016-09-12 23:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:13:42 UTC to 2016-09-13 00:14:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:33:42 UTC to 2016-09-13 00:34:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 00:53:42 UTC to 2016-09-13 00:54:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:13:41 UTC to 2016-09-13 01:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:33:41 UTC to 2016-09-13 01:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 01:53:41 UTC to 2016-09-13 01:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:13:41 UTC to 2016-09-13 02:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:33:41 UTC to 2016-09-13 02:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 02:53:41 UTC to 2016-09-13 02:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:13:41 UTC to 2016-09-13 03:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:33:41 UTC to 2016-09-13 03:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 03:53:41 UTC to 2016-09-13 03:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:13:41 UTC to 2016-09-13 04:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:33:41 UTC to 2016-09-13 04:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 04:53:41 UTC to 2016-09-13 04:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:13:41 UTC to 2016-09-13 05:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:33:41 UTC to 2016-09-13 05:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 05:53:41 UTC to 2016-09-13 05:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:13:41 UTC to 2016-09-13 06:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:33:41 UTC to 2016-09-13 06:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 06:53:41 UTC to 2016-09-13 06:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:13:41 UTC to 2016-09-13 07:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:33:41 UTC to 2016-09-13 07:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 07:53:41 UTC to 2016-09-13 07:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:13:41 UTC to 2016-09-13 08:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:33:41 UTC to 2016-09-13 08:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 08:53:41 UTC to 2016-09-13 08:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:13:41 UTC to 2016-09-13 09:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:33:41 UTC to 2016-09-13 09:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 09:53:41 UTC to 2016-09-13 09:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:13:41 UTC to 2016-09-13 10:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:33:41 UTC to 2016-09-13 10:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 10:53:41 UTC to 2016-09-13 10:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:13:41 UTC to 2016-09-13 11:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:33:41 UTC to 2016-09-13 11:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 11:53:41 UTC to 2016-09-13 11:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:13:41 UTC to 2016-09-13 12:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:33:41 UTC to 2016-09-13 12:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 12:53:41 UTC to 2016-09-13 12:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:13:41 UTC to 2016-09-13 13:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:33:41 UTC to 2016-09-13 13:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 13:53:41 UTC to 2016-09-13 13:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:13:41 UTC to 2016-09-13 14:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:33:41 UTC to 2016-09-13 14:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 14:53:41 UTC to 2016-09-13 14:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:13:41 UTC to 2016-09-13 15:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:33:41 UTC to 2016-09-13 15:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 15:53:41 UTC to 2016-09-13 15:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:13:41 UTC to 2016-09-13 16:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:33:41 UTC to 2016-09-13 16:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 16:53:41 UTC to 2016-09-13 16:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:13:41 UTC to 2016-09-13 17:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:33:41 UTC to 2016-09-13 17:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 17:53:41 UTC to 2016-09-13 17:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:13:41 UTC to 2016-09-13 18:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:33:41 UTC to 2016-09-13 18:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 18:53:41 UTC to 2016-09-13 18:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:13:41 UTC to 2016-09-13 19:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:33:41 UTC to 2016-09-13 19:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 19:53:41 UTC to 2016-09-13 19:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:13:41 UTC to 2016-09-13 20:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:33:41 UTC to 2016-09-13 20:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 20:53:41 UTC to 2016-09-13 20:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:13:41 UTC to 2016-09-13 21:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:33:41 UTC to 2016-09-13 21:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 21:53:41 UTC to 2016-09-13 21:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:13:41 UTC to 2016-09-13 22:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:33:41 UTC to 2016-09-13 22:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 22:53:41 UTC to 2016-09-13 22:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:13:41 UTC to 2016-09-13 23:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:33:41 UTC to 2016-09-13 23:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-13 23:53:41 UTC to 2016-09-13 23:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:13:41 UTC to 2016-09-14 00:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:33:41 UTC to 2016-09-14 00:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 00:53:41 UTC to 2016-09-14 00:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:13:41 UTC to 2016-09-14 01:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:33:41 UTC to 2016-09-14 01:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 01:53:41 UTC to 2016-09-14 01:54:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:13:41 UTC to 2016-09-14 02:14:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:33:41 UTC to 2016-09-14 02:34:01 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 02:53:40 UTC to 2016-09-14 02:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:13:40 UTC to 2016-09-14 03:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:33:40 UTC to 2016-09-14 03:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 03:53:40 UTC to 2016-09-14 03:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:13:40 UTC to 2016-09-14 04:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:33:40 UTC to 2016-09-14 04:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 04:53:40 UTC to 2016-09-14 04:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:13:40 UTC to 2016-09-14 05:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:33:40 UTC to 2016-09-14 05:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 05:53:40 UTC to 2016-09-14 05:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:13:40 UTC to 2016-09-14 06:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:33:40 UTC to 2016-09-14 06:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 06:53:40 UTC to 2016-09-14 06:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:13:40 UTC to 2016-09-14 07:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:33:40 UTC to 2016-09-14 07:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 07:53:40 UTC to 2016-09-14 07:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:13:40 UTC to 2016-09-14 08:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:33:40 UTC to 2016-09-14 08:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 08:53:40 UTC to 2016-09-14 08:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:13:40 UTC to 2016-09-14 09:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:33:40 UTC to 2016-09-14 09:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 09:53:40 UTC to 2016-09-14 09:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:13:47 UTC to 2016-09-14 10:14:07 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:33:40 UTC to 2016-09-14 10:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 10:53:40 UTC to 2016-09-14 10:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:13:40 UTC to 2016-09-14 11:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:33:40 UTC to 2016-09-14 11:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 11:53:40 UTC to 2016-09-14 11:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:13:40 UTC to 2016-09-14 12:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:33:40 UTC to 2016-09-14 12:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 12:53:40 UTC to 2016-09-14 12:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:13:40 UTC to 2016-09-14 13:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:33:40 UTC to 2016-09-14 13:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 13:53:40 UTC to 2016-09-14 13:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:13:40 UTC to 2016-09-14 14:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:33:40 UTC to 2016-09-14 14:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 14:53:40 UTC to 2016-09-14 14:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:13:40 UTC to 2016-09-14 15:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:33:40 UTC to 2016-09-14 15:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 15:53:40 UTC to 2016-09-14 15:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:13:40 UTC to 2016-09-14 16:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:33:40 UTC to 2016-09-14 16:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 16:53:40 UTC to 2016-09-14 16:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:13:40 UTC to 2016-09-14 17:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:33:40 UTC to 2016-09-14 17:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 17:53:40 UTC to 2016-09-14 17:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:13:40 UTC to 2016-09-14 18:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:33:40 UTC to 2016-09-14 18:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 18:53:40 UTC to 2016-09-14 18:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:13:40 UTC to 2016-09-14 19:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:33:40 UTC to 2016-09-14 19:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 19:53:40 UTC to 2016-09-14 19:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:13:40 UTC to 2016-09-14 20:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:33:40 UTC to 2016-09-14 20:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 20:53:40 UTC to 2016-09-14 20:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:13:40 UTC to 2016-09-14 21:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:33:40 UTC to 2016-09-14 21:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 21:53:40 UTC to 2016-09-14 21:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:13:40 UTC to 2016-09-14 22:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:33:40 UTC to 2016-09-14 22:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 22:53:40 UTC to 2016-09-14 22:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:13:40 UTC to 2016-09-14 23:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:33:40 UTC to 2016-09-14 23:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-14 23:53:40 UTC to 2016-09-14 23:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:13:40 UTC to 2016-09-15 00:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:33:40 UTC to 2016-09-15 00:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 00:53:40 UTC to 2016-09-15 00:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:13:40 UTC to 2016-09-15 01:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:33:40 UTC to 2016-09-15 01:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 01:53:40 UTC to 2016-09-15 01:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:13:40 UTC to 2016-09-15 02:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:33:40 UTC to 2016-09-15 02:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 02:53:40 UTC to 2016-09-15 02:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:13:40 UTC to 2016-09-15 03:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:33:40 UTC to 2016-09-15 03:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 03:53:40 UTC to 2016-09-15 03:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:13:40 UTC to 2016-09-15 04:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:33:40 UTC to 2016-09-15 04:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 04:53:40 UTC to 2016-09-15 04:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:13:40 UTC to 2016-09-15 05:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:33:39 UTC to 2016-09-15 05:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 05:53:40 UTC to 2016-09-15 05:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:13:40 UTC to 2016-09-15 06:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:33:40 UTC to 2016-09-15 06:34:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 06:53:40 UTC to 2016-09-15 06:54:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:13:40 UTC to 2016-09-15 07:14:00 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:33:39 UTC to 2016-09-15 07:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 07:53:39 UTC to 2016-09-15 07:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:13:39 UTC to 2016-09-15 08:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:33:39 UTC to 2016-09-15 08:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 08:53:39 UTC to 2016-09-15 08:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:13:39 UTC to 2016-09-15 09:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:33:39 UTC to 2016-09-15 09:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 09:53:39 UTC to 2016-09-15 09:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:13:39 UTC to 2016-09-15 10:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:33:39 UTC to 2016-09-15 10:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 10:53:39 UTC to 2016-09-15 10:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:13:39 UTC to 2016-09-15 11:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:33:39 UTC to 2016-09-15 11:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 11:53:39 UTC to 2016-09-15 11:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:13:39 UTC to 2016-09-15 12:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:33:39 UTC to 2016-09-15 12:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 12:53:39 UTC to 2016-09-15 12:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:13:39 UTC to 2016-09-15 13:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:33:39 UTC to 2016-09-15 13:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 13:53:39 UTC to 2016-09-15 13:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:13:39 UTC to 2016-09-15 14:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:33:39 UTC to 2016-09-15 14:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 14:53:39 UTC to 2016-09-15 14:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:13:39 UTC to 2016-09-15 15:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:33:39 UTC to 2016-09-15 15:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 15:53:39 UTC to 2016-09-15 15:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:13:39 UTC to 2016-09-15 16:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:33:39 UTC to 2016-09-15 16:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 16:53:39 UTC to 2016-09-15 16:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:13:39 UTC to 2016-09-15 17:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:33:39 UTC to 2016-09-15 17:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 17:53:39 UTC to 2016-09-15 17:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:13:39 UTC to 2016-09-15 18:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:33:39 UTC to 2016-09-15 18:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 18:53:39 UTC to 2016-09-15 18:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:13:39 UTC to 2016-09-15 19:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:33:39 UTC to 2016-09-15 19:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 19:53:39 UTC to 2016-09-15 19:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:13:39 UTC to 2016-09-15 20:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:33:39 UTC to 2016-09-15 20:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 20:53:39 UTC to 2016-09-15 20:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:13:39 UTC to 2016-09-15 21:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:33:39 UTC to 2016-09-15 21:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 21:53:39 UTC to 2016-09-15 21:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:13:39 UTC to 2016-09-15 22:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:33:39 UTC to 2016-09-15 22:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 22:53:39 UTC to 2016-09-15 22:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:13:39 UTC to 2016-09-15 23:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:33:39 UTC to 2016-09-15 23:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-15 23:53:39 UTC to 2016-09-15 23:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:13:39 UTC to 2016-09-16 00:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:33:39 UTC to 2016-09-16 00:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 00:53:39 UTC to 2016-09-16 00:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:13:39 UTC to 2016-09-16 01:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:33:39 UTC to 2016-09-16 01:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 01:53:39 UTC to 2016-09-16 01:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:13:39 UTC to 2016-09-16 02:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:33:39 UTC to 2016-09-16 02:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 02:53:39 UTC to 2016-09-16 02:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:13:39 UTC to 2016-09-16 03:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:33:39 UTC to 2016-09-16 03:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 03:53:39 UTC to 2016-09-16 03:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:13:39 UTC to 2016-09-16 04:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:33:39 UTC to 2016-09-16 04:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 04:53:39 UTC to 2016-09-16 04:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:13:39 UTC to 2016-09-16 05:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:33:39 UTC to 2016-09-16 05:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 05:53:39 UTC to 2016-09-16 05:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:13:39 UTC to 2016-09-16 06:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:33:39 UTC to 2016-09-16 06:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 06:53:39 UTC to 2016-09-16 06:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:13:39 UTC to 2016-09-16 07:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:33:39 UTC to 2016-09-16 07:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 07:53:39 UTC to 2016-09-16 07:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:13:39 UTC to 2016-09-16 08:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:33:39 UTC to 2016-09-16 08:33:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 08:53:39 UTC to 2016-09-16 08:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:13:39 UTC to 2016-09-16 09:13:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:33:38 UTC to 2016-09-16 09:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 09:53:39 UTC to 2016-09-16 09:53:59 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:13:38 UTC to 2016-09-16 10:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:33:38 UTC to 2016-09-16 10:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 10:53:38 UTC to 2016-09-16 10:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:13:38 UTC to 2016-09-16 11:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:33:38 UTC to 2016-09-16 11:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 11:53:38 UTC to 2016-09-16 11:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:13:38 UTC to 2016-09-16 12:13:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:33:38 UTC to 2016-09-16 12:33:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-16 12:53:38 UTC to 2016-09-16 12:53:58 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 19:55:13 UTC to 2016-09-18 19:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:15:13 UTC to 2016-09-18 20:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:35:13 UTC to 2016-09-18 20:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 20:55:13 UTC to 2016-09-18 20:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:15:13 UTC to 2016-09-18 21:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:35:13 UTC to 2016-09-18 21:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 21:55:13 UTC to 2016-09-18 21:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:15:13 UTC to 2016-09-18 22:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:35:13 UTC to 2016-09-18 22:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 22:55:13 UTC to 2016-09-18 22:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:15:13 UTC to 2016-09-18 23:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:35:13 UTC to 2016-09-18 23:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-18 23:55:13 UTC to 2016-09-18 23:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:15:13 UTC to 2016-09-19 00:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:35:13 UTC to 2016-09-19 00:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 00:55:13 UTC to 2016-09-19 00:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:15:13 UTC to 2016-09-19 01:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:35:13 UTC to 2016-09-19 01:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 01:55:13 UTC to 2016-09-19 01:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:15:13 UTC to 2016-09-19 02:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:35:13 UTC to 2016-09-19 02:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 02:55:13 UTC to 2016-09-19 02:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:15:13 UTC to 2016-09-19 03:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:35:13 UTC to 2016-09-19 03:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 03:55:13 UTC to 2016-09-19 03:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:15:13 UTC to 2016-09-19 04:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:35:13 UTC to 2016-09-19 04:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 04:55:13 UTC to 2016-09-19 04:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:15:13 UTC to 2016-09-19 05:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:35:13 UTC to 2016-09-19 05:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 05:55:13 UTC to 2016-09-19 05:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:15:13 UTC to 2016-09-19 06:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:35:13 UTC to 2016-09-19 06:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 06:55:13 UTC to 2016-09-19 06:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:15:13 UTC to 2016-09-19 07:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:35:13 UTC to 2016-09-19 07:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 07:55:13 UTC to 2016-09-19 07:55:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:15:13 UTC to 2016-09-19 08:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:35:13 UTC to 2016-09-19 08:35:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 08:55:12 UTC to 2016-09-19 08:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:15:13 UTC to 2016-09-19 09:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:35:12 UTC to 2016-09-19 09:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 09:55:12 UTC to 2016-09-19 09:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:15:13 UTC to 2016-09-19 10:15:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:35:12 UTC to 2016-09-19 10:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 10:55:12 UTC to 2016-09-19 10:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:15:12 UTC to 2016-09-19 11:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:35:12 UTC to 2016-09-19 11:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 11:55:30 UTC to 2016-09-19 11:55:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:15:30 UTC to 2016-09-19 12:15:50 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:37:25 UTC to 2016-09-19 12:37:45 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 12:59:09 UTC to 2016-09-19 12:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:20:42 UTC to 2016-09-19 13:21:02 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:45:52 UTC to 2016-09-19 13:46:12 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 13:58:06 UTC to 2016-09-19 13:58:26 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:15:12 UTC to 2016-09-19 14:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:35:12 UTC to 2016-09-19 14:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 14:55:12 UTC to 2016-09-19 14:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:15:12 UTC to 2016-09-19 15:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:35:12 UTC to 2016-09-19 15:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 15:55:12 UTC to 2016-09-19 15:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:15:12 UTC to 2016-09-19 16:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:35:12 UTC to 2016-09-19 16:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 16:55:12 UTC to 2016-09-19 16:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:15:12 UTC to 2016-09-19 17:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:35:12 UTC to 2016-09-19 17:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 17:55:12 UTC to 2016-09-19 17:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:15:12 UTC to 2016-09-19 18:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:35:12 UTC to 2016-09-19 18:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 18:55:12 UTC to 2016-09-19 18:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:15:12 UTC to 2016-09-19 19:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:35:12 UTC to 2016-09-19 19:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 19:55:12 UTC to 2016-09-19 19:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:15:12 UTC to 2016-09-19 20:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:35:12 UTC to 2016-09-19 20:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 20:55:12 UTC to 2016-09-19 20:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:15:12 UTC to 2016-09-19 21:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:35:12 UTC to 2016-09-19 21:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 21:55:12 UTC to 2016-09-19 21:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:15:12 UTC to 2016-09-19 22:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:35:12 UTC to 2016-09-19 22:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 22:55:12 UTC to 2016-09-19 22:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:15:12 UTC to 2016-09-19 23:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:35:12 UTC to 2016-09-19 23:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-19 23:55:12 UTC to 2016-09-19 23:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:15:12 UTC to 2016-09-20 00:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:35:12 UTC to 2016-09-20 00:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 00:55:12 UTC to 2016-09-20 00:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:15:12 UTC to 2016-09-20 01:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:35:12 UTC to 2016-09-20 01:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 01:55:12 UTC to 2016-09-20 01:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:15:12 UTC to 2016-09-20 02:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:35:12 UTC to 2016-09-20 02:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 02:55:12 UTC to 2016-09-20 02:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:15:12 UTC to 2016-09-20 03:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:35:12 UTC to 2016-09-20 03:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 03:55:12 UTC to 2016-09-20 03:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:15:12 UTC to 2016-09-20 04:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:35:12 UTC to 2016-09-20 04:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 04:55:12 UTC to 2016-09-20 04:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:15:12 UTC to 2016-09-20 05:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:35:12 UTC to 2016-09-20 05:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 05:55:12 UTC to 2016-09-20 05:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:15:12 UTC to 2016-09-20 06:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:35:12 UTC to 2016-09-20 06:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 06:55:12 UTC to 2016-09-20 06:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:15:12 UTC to 2016-09-20 07:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:35:12 UTC to 2016-09-20 07:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 07:55:12 UTC to 2016-09-20 07:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:15:12 UTC to 2016-09-20 08:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:35:12 UTC to 2016-09-20 08:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 08:55:12 UTC to 2016-09-20 08:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:15:12 UTC to 2016-09-20 09:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:35:12 UTC to 2016-09-20 09:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 09:55:12 UTC to 2016-09-20 09:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:15:12 UTC to 2016-09-20 10:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:35:12 UTC to 2016-09-20 10:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 10:55:12 UTC to 2016-09-20 10:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:15:12 UTC to 2016-09-20 11:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:35:12 UTC to 2016-09-20 11:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 11:55:11 UTC to 2016-09-20 11:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:15:11 UTC to 2016-09-20 12:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:35:11 UTC to 2016-09-20 12:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 12:55:11 UTC to 2016-09-20 12:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:15:12 UTC to 2016-09-20 13:15:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:35:12 UTC to 2016-09-20 13:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 13:55:12 UTC to 2016-09-20 13:55:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:15:11 UTC to 2016-09-20 14:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:35:12 UTC to 2016-09-20 14:35:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 14:55:11 UTC to 2016-09-20 14:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:15:11 UTC to 2016-09-20 15:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:35:11 UTC to 2016-09-20 15:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 15:55:11 UTC to 2016-09-20 15:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:15:11 UTC to 2016-09-20 16:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:35:11 UTC to 2016-09-20 16:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 16:55:11 UTC to 2016-09-20 16:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:15:11 UTC to 2016-09-20 17:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:35:11 UTC to 2016-09-20 17:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 17:55:11 UTC to 2016-09-20 17:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:15:11 UTC to 2016-09-20 18:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:35:11 UTC to 2016-09-20 18:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 18:55:11 UTC to 2016-09-20 18:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:15:11 UTC to 2016-09-20 19:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:35:11 UTC to 2016-09-20 19:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 19:55:11 UTC to 2016-09-20 19:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:15:11 UTC to 2016-09-20 20:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:35:11 UTC to 2016-09-20 20:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 20:55:11 UTC to 2016-09-20 20:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:15:11 UTC to 2016-09-20 21:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:35:11 UTC to 2016-09-20 21:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 21:55:11 UTC to 2016-09-20 21:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:15:11 UTC to 2016-09-20 22:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:35:11 UTC to 2016-09-20 22:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 22:55:11 UTC to 2016-09-20 22:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:15:11 UTC to 2016-09-20 23:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:35:11 UTC to 2016-09-20 23:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-20 23:55:11 UTC to 2016-09-20 23:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:15:11 UTC to 2016-09-21 00:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:35:11 UTC to 2016-09-21 00:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 00:55:11 UTC to 2016-09-21 00:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:15:11 UTC to 2016-09-21 01:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:35:11 UTC to 2016-09-21 01:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 01:55:11 UTC to 2016-09-21 01:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:15:11 UTC to 2016-09-21 02:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:35:11 UTC to 2016-09-21 02:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 02:55:11 UTC to 2016-09-21 02:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:15:11 UTC to 2016-09-21 03:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:35:11 UTC to 2016-09-21 03:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 03:55:11 UTC to 2016-09-21 03:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:15:11 UTC to 2016-09-21 04:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:35:11 UTC to 2016-09-21 04:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 04:55:11 UTC to 2016-09-21 04:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:15:11 UTC to 2016-09-21 05:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:35:11 UTC to 2016-09-21 05:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 05:55:11 UTC to 2016-09-21 05:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:15:11 UTC to 2016-09-21 06:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:35:11 UTC to 2016-09-21 06:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 06:55:11 UTC to 2016-09-21 06:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:15:11 UTC to 2016-09-21 07:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:35:11 UTC to 2016-09-21 07:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 07:55:11 UTC to 2016-09-21 07:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:15:11 UTC to 2016-09-21 08:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:35:11 UTC to 2016-09-21 08:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 08:55:11 UTC to 2016-09-21 08:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:15:11 UTC to 2016-09-21 09:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:35:11 UTC to 2016-09-21 09:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 09:55:11 UTC to 2016-09-21 09:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:15:11 UTC to 2016-09-21 10:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:35:11 UTC to 2016-09-21 10:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 10:55:11 UTC to 2016-09-21 10:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:15:11 UTC to 2016-09-21 11:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:35:11 UTC to 2016-09-21 11:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 11:55:11 UTC to 2016-09-21 11:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:15:11 UTC to 2016-09-21 12:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:35:11 UTC to 2016-09-21 12:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 12:55:11 UTC to 2016-09-21 12:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:15:11 UTC to 2016-09-21 13:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:35:11 UTC to 2016-09-21 13:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 13:55:11 UTC to 2016-09-21 13:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:15:11 UTC to 2016-09-21 14:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:35:10 UTC to 2016-09-21 14:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 14:55:11 UTC to 2016-09-21 14:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:15:11 UTC to 2016-09-21 15:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:35:11 UTC to 2016-09-21 15:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 15:55:11 UTC to 2016-09-21 15:55:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:15:10 UTC to 2016-09-21 16:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:35:11 UTC to 2016-09-21 16:35:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 16:55:10 UTC to 2016-09-21 16:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:15:10 UTC to 2016-09-21 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:35:10 UTC to 2016-09-21 17:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 17:55:10 UTC to 2016-09-21 17:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:15:10 UTC to 2016-09-21 18:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:35:10 UTC to 2016-09-21 18:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 18:55:10 UTC to 2016-09-21 18:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:15:11 UTC to 2016-09-21 19:15:31 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:35:10 UTC to 2016-09-21 19:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 19:55:10 UTC to 2016-09-21 19:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:15:10 UTC to 2016-09-21 20:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:35:10 UTC to 2016-09-21 20:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 20:55:10 UTC to 2016-09-21 20:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:15:10 UTC to 2016-09-21 21:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:35:10 UTC to 2016-09-21 21:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 21:55:10 UTC to 2016-09-21 21:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:15:10 UTC to 2016-09-21 22:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:35:10 UTC to 2016-09-21 22:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 22:55:10 UTC to 2016-09-21 22:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:15:10 UTC to 2016-09-21 23:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:35:10 UTC to 2016-09-21 23:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-21 23:55:10 UTC to 2016-09-21 23:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:15:10 UTC to 2016-09-22 00:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:35:10 UTC to 2016-09-22 00:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 00:55:10 UTC to 2016-09-22 00:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:15:10 UTC to 2016-09-22 01:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:35:10 UTC to 2016-09-22 01:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 01:55:10 UTC to 2016-09-22 01:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:15:10 UTC to 2016-09-22 02:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:35:10 UTC to 2016-09-22 02:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 02:55:10 UTC to 2016-09-22 02:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:15:10 UTC to 2016-09-22 03:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:35:10 UTC to 2016-09-22 03:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 03:55:10 UTC to 2016-09-22 03:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:15:10 UTC to 2016-09-22 04:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:35:10 UTC to 2016-09-22 04:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 04:55:10 UTC to 2016-09-22 04:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:15:10 UTC to 2016-09-22 05:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:35:10 UTC to 2016-09-22 05:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 05:55:10 UTC to 2016-09-22 05:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:15:10 UTC to 2016-09-22 06:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:35:10 UTC to 2016-09-22 06:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 06:55:10 UTC to 2016-09-22 06:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:15:10 UTC to 2016-09-22 07:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:35:10 UTC to 2016-09-22 07:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 07:55:10 UTC to 2016-09-22 07:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:15:10 UTC to 2016-09-22 08:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:35:10 UTC to 2016-09-22 08:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 08:55:10 UTC to 2016-09-22 08:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:15:10 UTC to 2016-09-22 09:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:35:10 UTC to 2016-09-22 09:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 09:55:10 UTC to 2016-09-22 09:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:15:10 UTC to 2016-09-22 10:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:35:10 UTC to 2016-09-22 10:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 10:55:10 UTC to 2016-09-22 10:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:15:10 UTC to 2016-09-22 11:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:35:10 UTC to 2016-09-22 11:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 11:55:10 UTC to 2016-09-22 11:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:15:10 UTC to 2016-09-22 12:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:35:10 UTC to 2016-09-22 12:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 12:55:10 UTC to 2016-09-22 12:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:15:10 UTC to 2016-09-22 13:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:35:10 UTC to 2016-09-22 13:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 13:55:10 UTC to 2016-09-22 13:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:15:10 UTC to 2016-09-22 14:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:35:10 UTC to 2016-09-22 14:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 14:55:10 UTC to 2016-09-22 14:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:15:10 UTC to 2016-09-22 15:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:35:10 UTC to 2016-09-22 15:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 15:55:10 UTC to 2016-09-22 15:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:15:10 UTC to 2016-09-22 16:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:35:10 UTC to 2016-09-22 16:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 16:55:09 UTC to 2016-09-22 16:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:15:10 UTC to 2016-09-22 17:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:35:10 UTC to 2016-09-22 17:35:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 17:55:10 UTC to 2016-09-22 17:55:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:15:09 UTC to 2016-09-22 18:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:35:09 UTC to 2016-09-22 18:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 18:55:09 UTC to 2016-09-22 18:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:15:09 UTC to 2016-09-22 19:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:35:09 UTC to 2016-09-22 19:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 19:55:09 UTC to 2016-09-22 19:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:15:09 UTC to 2016-09-22 20:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:35:09 UTC to 2016-09-22 20:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 20:55:09 UTC to 2016-09-22 20:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:15:10 UTC to 2016-09-22 21:15:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:35:09 UTC to 2016-09-22 21:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 21:55:09 UTC to 2016-09-22 21:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:15:09 UTC to 2016-09-22 22:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:35:09 UTC to 2016-09-22 22:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 22:55:09 UTC to 2016-09-22 22:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:15:09 UTC to 2016-09-22 23:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:35:09 UTC to 2016-09-22 23:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-22 23:55:09 UTC to 2016-09-22 23:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:15:09 UTC to 2016-09-23 00:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:35:09 UTC to 2016-09-23 00:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 00:55:09 UTC to 2016-09-23 00:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:15:09 UTC to 2016-09-23 01:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:35:09 UTC to 2016-09-23 01:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 01:55:09 UTC to 2016-09-23 01:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:15:09 UTC to 2016-09-23 02:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:35:09 UTC to 2016-09-23 02:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 02:55:09 UTC to 2016-09-23 02:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:15:09 UTC to 2016-09-23 03:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:35:09 UTC to 2016-09-23 03:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 03:55:09 UTC to 2016-09-23 03:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:15:09 UTC to 2016-09-23 04:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:35:09 UTC to 2016-09-23 04:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 04:55:09 UTC to 2016-09-23 04:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:15:09 UTC to 2016-09-23 05:15:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:35:09 UTC to 2016-09-23 05:35:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-23 05:55:09 UTC to 2016-09-23 05:55:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 15:36:14 UTC to 2016-09-24 15:36:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 15:46:14 UTC to 2016-09-24 15:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:06:14 UTC to 2016-09-24 16:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:26:14 UTC to 2016-09-24 16:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 16:46:14 UTC to 2016-09-24 16:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:06:14 UTC to 2016-09-24 17:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:26:14 UTC to 2016-09-24 17:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 17:46:14 UTC to 2016-09-24 17:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:06:14 UTC to 2016-09-24 18:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:26:14 UTC to 2016-09-24 18:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 18:46:14 UTC to 2016-09-24 18:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:06:14 UTC to 2016-09-24 19:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:26:14 UTC to 2016-09-24 19:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 19:46:14 UTC to 2016-09-24 19:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:06:14 UTC to 2016-09-24 20:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:26:14 UTC to 2016-09-24 20:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 20:46:14 UTC to 2016-09-24 20:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:06:14 UTC to 2016-09-24 21:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:26:14 UTC to 2016-09-24 21:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 21:46:14 UTC to 2016-09-24 21:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:06:14 UTC to 2016-09-24 22:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:26:14 UTC to 2016-09-24 22:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 22:46:14 UTC to 2016-09-24 22:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:06:14 UTC to 2016-09-24 23:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:26:14 UTC to 2016-09-24 23:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-24 23:46:14 UTC to 2016-09-24 23:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:06:14 UTC to 2016-09-25 00:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:26:14 UTC to 2016-09-25 00:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 00:46:14 UTC to 2016-09-25 00:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:06:14 UTC to 2016-09-25 01:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:26:14 UTC to 2016-09-25 01:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 01:46:14 UTC to 2016-09-25 01:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:06:14 UTC to 2016-09-25 02:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:26:14 UTC to 2016-09-25 02:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 02:46:14 UTC to 2016-09-25 02:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:06:14 UTC to 2016-09-25 03:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:26:14 UTC to 2016-09-25 03:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 03:46:14 UTC to 2016-09-25 03:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:06:14 UTC to 2016-09-25 04:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:26:14 UTC to 2016-09-25 04:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 04:46:14 UTC to 2016-09-25 04:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:06:14 UTC to 2016-09-25 05:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:26:14 UTC to 2016-09-25 05:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 05:46:14 UTC to 2016-09-25 05:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:06:14 UTC to 2016-09-25 06:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:26:14 UTC to 2016-09-25 06:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 06:46:14 UTC to 2016-09-25 06:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:06:14 UTC to 2016-09-25 07:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:26:14 UTC to 2016-09-25 07:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 07:46:14 UTC to 2016-09-25 07:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:06:14 UTC to 2016-09-25 08:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:26:14 UTC to 2016-09-25 08:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 08:46:14 UTC to 2016-09-25 08:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:06:14 UTC to 2016-09-25 09:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:26:14 UTC to 2016-09-25 09:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 09:46:13 UTC to 2016-09-25 09:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:06:14 UTC to 2016-09-25 10:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:26:13 UTC to 2016-09-25 10:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 10:46:14 UTC to 2016-09-25 10:46:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:06:13 UTC to 2016-09-25 11:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:26:14 UTC to 2016-09-25 11:26:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 11:46:13 UTC to 2016-09-25 11:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:06:13 UTC to 2016-09-25 12:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:26:13 UTC to 2016-09-25 12:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 12:46:13 UTC to 2016-09-25 12:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:06:14 UTC to 2016-09-25 13:06:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:26:13 UTC to 2016-09-25 13:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 13:46:13 UTC to 2016-09-25 13:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:06:13 UTC to 2016-09-25 14:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:26:13 UTC to 2016-09-25 14:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 14:46:13 UTC to 2016-09-25 14:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:06:13 UTC to 2016-09-25 15:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:26:13 UTC to 2016-09-25 15:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 15:46:13 UTC to 2016-09-25 15:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:06:13 UTC to 2016-09-25 16:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:26:13 UTC to 2016-09-25 16:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 16:46:13 UTC to 2016-09-25 16:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:06:13 UTC to 2016-09-25 17:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:26:13 UTC to 2016-09-25 17:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 17:46:13 UTC to 2016-09-25 17:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:06:13 UTC to 2016-09-25 18:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:26:13 UTC to 2016-09-25 18:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 18:46:13 UTC to 2016-09-25 18:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:06:13 UTC to 2016-09-25 19:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:26:13 UTC to 2016-09-25 19:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 19:46:13 UTC to 2016-09-25 19:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:06:13 UTC to 2016-09-25 20:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:26:13 UTC to 2016-09-25 20:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 20:46:13 UTC to 2016-09-25 20:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:06:13 UTC to 2016-09-25 21:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:26:13 UTC to 2016-09-25 21:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 21:46:13 UTC to 2016-09-25 21:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:06:13 UTC to 2016-09-25 22:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:26:13 UTC to 2016-09-25 22:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 22:46:13 UTC to 2016-09-25 22:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:06:13 UTC to 2016-09-25 23:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:26:13 UTC to 2016-09-25 23:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-25 23:46:13 UTC to 2016-09-25 23:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:06:13 UTC to 2016-09-26 00:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:26:13 UTC to 2016-09-26 00:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 00:46:13 UTC to 2016-09-26 00:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:06:13 UTC to 2016-09-26 01:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:26:13 UTC to 2016-09-26 01:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 01:46:13 UTC to 2016-09-26 01:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:06:13 UTC to 2016-09-26 02:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:26:13 UTC to 2016-09-26 02:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 02:46:13 UTC to 2016-09-26 02:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:06:13 UTC to 2016-09-26 03:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:26:13 UTC to 2016-09-26 03:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 03:46:13 UTC to 2016-09-26 03:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:06:13 UTC to 2016-09-26 04:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:26:13 UTC to 2016-09-26 04:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 04:46:13 UTC to 2016-09-26 04:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:06:13 UTC to 2016-09-26 05:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:26:13 UTC to 2016-09-26 05:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 05:46:13 UTC to 2016-09-26 05:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:06:13 UTC to 2016-09-26 06:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:26:13 UTC to 2016-09-26 06:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 06:46:13 UTC to 2016-09-26 06:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:06:13 UTC to 2016-09-26 07:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:26:13 UTC to 2016-09-26 07:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 07:46:13 UTC to 2016-09-26 07:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:06:13 UTC to 2016-09-26 08:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:26:13 UTC to 2016-09-26 08:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 08:46:13 UTC to 2016-09-26 08:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:06:13 UTC to 2016-09-26 09:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:26:13 UTC to 2016-09-26 09:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 09:46:13 UTC to 2016-09-26 09:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:06:13 UTC to 2016-09-26 10:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:26:13 UTC to 2016-09-26 10:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 10:46:13 UTC to 2016-09-26 10:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:06:13 UTC to 2016-09-26 11:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:26:13 UTC to 2016-09-26 11:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 11:46:13 UTC to 2016-09-26 11:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:06:13 UTC to 2016-09-26 12:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:26:13 UTC to 2016-09-26 12:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 12:46:13 UTC to 2016-09-26 12:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:06:13 UTC to 2016-09-26 13:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:26:12 UTC to 2016-09-26 13:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 13:46:13 UTC to 2016-09-26 13:46:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:06:13 UTC to 2016-09-26 14:06:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:26:12 UTC to 2016-09-26 14:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 14:46:12 UTC to 2016-09-26 14:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:06:12 UTC to 2016-09-26 15:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:26:12 UTC to 2016-09-26 15:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 15:46:12 UTC to 2016-09-26 15:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:06:12 UTC to 2016-09-26 16:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:26:13 UTC to 2016-09-26 16:26:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 16:46:12 UTC to 2016-09-26 16:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:06:12 UTC to 2016-09-26 17:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:26:12 UTC to 2016-09-26 17:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 17:46:12 UTC to 2016-09-26 17:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:06:12 UTC to 2016-09-26 18:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:26:12 UTC to 2016-09-26 18:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 18:46:12 UTC to 2016-09-26 18:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:06:12 UTC to 2016-09-26 19:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:26:12 UTC to 2016-09-26 19:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 19:46:12 UTC to 2016-09-26 19:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:06:12 UTC to 2016-09-26 20:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:26:12 UTC to 2016-09-26 20:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 20:46:12 UTC to 2016-09-26 20:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:06:12 UTC to 2016-09-26 21:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:26:12 UTC to 2016-09-26 21:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 21:46:12 UTC to 2016-09-26 21:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:06:12 UTC to 2016-09-26 22:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:26:12 UTC to 2016-09-26 22:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 22:46:12 UTC to 2016-09-26 22:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:06:12 UTC to 2016-09-26 23:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:26:12 UTC to 2016-09-26 23:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-26 23:46:12 UTC to 2016-09-26 23:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:06:12 UTC to 2016-09-27 00:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:26:12 UTC to 2016-09-27 00:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 00:46:12 UTC to 2016-09-27 00:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:06:12 UTC to 2016-09-27 01:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:26:12 UTC to 2016-09-27 01:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 01:46:12 UTC to 2016-09-27 01:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:06:12 UTC to 2016-09-27 02:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:26:12 UTC to 2016-09-27 02:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 02:46:12 UTC to 2016-09-27 02:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:06:12 UTC to 2016-09-27 03:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:26:12 UTC to 2016-09-27 03:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 03:46:12 UTC to 2016-09-27 03:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:06:12 UTC to 2016-09-27 04:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:26:12 UTC to 2016-09-27 04:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 04:46:12 UTC to 2016-09-27 04:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:06:12 UTC to 2016-09-27 05:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:26:12 UTC to 2016-09-27 05:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 05:46:12 UTC to 2016-09-27 05:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:06:12 UTC to 2016-09-27 06:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:26:12 UTC to 2016-09-27 06:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 06:46:12 UTC to 2016-09-27 06:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:06:12 UTC to 2016-09-27 07:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:26:12 UTC to 2016-09-27 07:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 07:46:12 UTC to 2016-09-27 07:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:06:12 UTC to 2016-09-27 08:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:26:12 UTC to 2016-09-27 08:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 08:46:12 UTC to 2016-09-27 08:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:06:12 UTC to 2016-09-27 09:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:26:12 UTC to 2016-09-27 09:26:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 09:46:12 UTC to 2016-09-27 09:46:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 10:06:12 UTC to 2016-09-27 10:06:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:07:15 UTC to 2016-09-27 22:07:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:17:15 UTC to 2016-09-27 22:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:37:15 UTC to 2016-09-27 22:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 22:57:15 UTC to 2016-09-27 22:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:17:15 UTC to 2016-09-27 23:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:37:15 UTC to 2016-09-27 23:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-27 23:57:15 UTC to 2016-09-27 23:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:17:15 UTC to 2016-09-28 00:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:37:15 UTC to 2016-09-28 00:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 00:57:15 UTC to 2016-09-28 00:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:17:15 UTC to 2016-09-28 01:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:37:15 UTC to 2016-09-28 01:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 01:57:15 UTC to 2016-09-28 01:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:17:15 UTC to 2016-09-28 02:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:37:15 UTC to 2016-09-28 02:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 02:57:15 UTC to 2016-09-28 02:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:17:15 UTC to 2016-09-28 03:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:37:19 UTC to 2016-09-28 03:37:39 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 03:57:15 UTC to 2016-09-28 03:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:17:15 UTC to 2016-09-28 04:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:37:15 UTC to 2016-09-28 04:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 04:57:15 UTC to 2016-09-28 04:57:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:17:15 UTC to 2016-09-28 05:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:37:15 UTC to 2016-09-28 05:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 05:57:14 UTC to 2016-09-28 05:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:17:14 UTC to 2016-09-28 06:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:37:14 UTC to 2016-09-28 06:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 06:57:21 UTC to 2016-09-28 06:57:41 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:17:14 UTC to 2016-09-28 07:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:37:15 UTC to 2016-09-28 07:37:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 07:57:14 UTC to 2016-09-28 07:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:17:14 UTC to 2016-09-28 08:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:37:14 UTC to 2016-09-28 08:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 08:57:14 UTC to 2016-09-28 08:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:17:14 UTC to 2016-09-28 09:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:37:14 UTC to 2016-09-28 09:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 09:57:14 UTC to 2016-09-28 09:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:17:14 UTC to 2016-09-28 10:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:37:14 UTC to 2016-09-28 10:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 10:57:14 UTC to 2016-09-28 10:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:17:14 UTC to 2016-09-28 11:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:37:14 UTC to 2016-09-28 11:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 11:57:14 UTC to 2016-09-28 11:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:17:14 UTC to 2016-09-28 12:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:37:14 UTC to 2016-09-28 12:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 12:57:14 UTC to 2016-09-28 12:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:17:14 UTC to 2016-09-28 13:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:37:14 UTC to 2016-09-28 13:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 13:57:14 UTC to 2016-09-28 13:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:17:14 UTC to 2016-09-28 14:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:37:14 UTC to 2016-09-28 14:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 14:57:14 UTC to 2016-09-28 14:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:17:14 UTC to 2016-09-28 15:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:37:14 UTC to 2016-09-28 15:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 15:57:14 UTC to 2016-09-28 15:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:17:14 UTC to 2016-09-28 16:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:37:14 UTC to 2016-09-28 16:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 16:57:14 UTC to 2016-09-28 16:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:17:14 UTC to 2016-09-28 17:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:37:14 UTC to 2016-09-28 17:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 17:57:14 UTC to 2016-09-28 17:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:17:14 UTC to 2016-09-28 18:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:37:14 UTC to 2016-09-28 18:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 18:57:14 UTC to 2016-09-28 18:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:17:14 UTC to 2016-09-28 19:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:37:14 UTC to 2016-09-28 19:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 19:57:14 UTC to 2016-09-28 19:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:17:14 UTC to 2016-09-28 20:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:37:14 UTC to 2016-09-28 20:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 20:57:14 UTC to 2016-09-28 20:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:17:14 UTC to 2016-09-28 21:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:37:14 UTC to 2016-09-28 21:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 21:57:14 UTC to 2016-09-28 21:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:17:14 UTC to 2016-09-28 22:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:37:14 UTC to 2016-09-28 22:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 22:57:14 UTC to 2016-09-28 22:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:17:14 UTC to 2016-09-28 23:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:37:14 UTC to 2016-09-28 23:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-28 23:57:14 UTC to 2016-09-28 23:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:17:14 UTC to 2016-09-29 00:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:37:14 UTC to 2016-09-29 00:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 00:57:14 UTC to 2016-09-29 00:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:17:14 UTC to 2016-09-29 01:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:37:14 UTC to 2016-09-29 01:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 01:57:14 UTC to 2016-09-29 01:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:17:14 UTC to 2016-09-29 02:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:37:14 UTC to 2016-09-29 02:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 02:57:14 UTC to 2016-09-29 02:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:17:14 UTC to 2016-09-29 03:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:37:14 UTC to 2016-09-29 03:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 03:57:14 UTC to 2016-09-29 03:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:17:14 UTC to 2016-09-29 04:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:37:14 UTC to 2016-09-29 04:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 04:57:14 UTC to 2016-09-29 04:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:17:14 UTC to 2016-09-29 05:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:37:14 UTC to 2016-09-29 05:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 05:57:14 UTC to 2016-09-29 05:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:17:14 UTC to 2016-09-29 06:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:37:14 UTC to 2016-09-29 06:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 06:57:14 UTC to 2016-09-29 06:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:17:14 UTC to 2016-09-29 07:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:37:14 UTC to 2016-09-29 07:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 07:57:14 UTC to 2016-09-29 07:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:17:14 UTC to 2016-09-29 08:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:37:14 UTC to 2016-09-29 08:37:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 08:57:14 UTC to 2016-09-29 08:57:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:17:14 UTC to 2016-09-29 09:17:34 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:37:13 UTC to 2016-09-29 09:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 09:57:13 UTC to 2016-09-29 09:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:17:13 UTC to 2016-09-29 10:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:37:13 UTC to 2016-09-29 10:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 10:57:13 UTC to 2016-09-29 10:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:17:13 UTC to 2016-09-29 11:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:37:13 UTC to 2016-09-29 11:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 11:57:13 UTC to 2016-09-29 11:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:17:13 UTC to 2016-09-29 12:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:37:13 UTC to 2016-09-29 12:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 12:57:13 UTC to 2016-09-29 12:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:17:13 UTC to 2016-09-29 13:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:37:13 UTC to 2016-09-29 13:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 13:57:13 UTC to 2016-09-29 13:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:17:13 UTC to 2016-09-29 14:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:37:13 UTC to 2016-09-29 14:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 14:57:13 UTC to 2016-09-29 14:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:17:15 UTC to 2016-09-29 15:17:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:37:13 UTC to 2016-09-29 15:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 15:57:13 UTC to 2016-09-29 15:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:17:13 UTC to 2016-09-29 16:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:37:13 UTC to 2016-09-29 16:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 16:57:13 UTC to 2016-09-29 16:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:17:13 UTC to 2016-09-29 17:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:37:13 UTC to 2016-09-29 17:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 17:57:13 UTC to 2016-09-29 17:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:17:13 UTC to 2016-09-29 18:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:37:13 UTC to 2016-09-29 18:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 18:57:13 UTC to 2016-09-29 18:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:17:13 UTC to 2016-09-29 19:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:37:13 UTC to 2016-09-29 19:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 19:57:13 UTC to 2016-09-29 19:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:17:13 UTC to 2016-09-29 20:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:37:13 UTC to 2016-09-29 20:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 20:57:13 UTC to 2016-09-29 20:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:17:13 UTC to 2016-09-29 21:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:37:13 UTC to 2016-09-29 21:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 21:57:13 UTC to 2016-09-29 21:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:17:13 UTC to 2016-09-29 22:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:37:13 UTC to 2016-09-29 22:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 22:57:13 UTC to 2016-09-29 22:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:17:13 UTC to 2016-09-29 23:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:37:13 UTC to 2016-09-29 23:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-29 23:57:13 UTC to 2016-09-29 23:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:17:13 UTC to 2016-09-30 00:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:37:13 UTC to 2016-09-30 00:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 00:57:13 UTC to 2016-09-30 00:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:17:13 UTC to 2016-09-30 01:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:37:13 UTC to 2016-09-30 01:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 01:57:13 UTC to 2016-09-30 01:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:17:13 UTC to 2016-09-30 02:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:37:13 UTC to 2016-09-30 02:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 02:57:13 UTC to 2016-09-30 02:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:17:13 UTC to 2016-09-30 03:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:37:13 UTC to 2016-09-30 03:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 03:57:13 UTC to 2016-09-30 03:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:17:13 UTC to 2016-09-30 04:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:37:13 UTC to 2016-09-30 04:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 04:57:13 UTC to 2016-09-30 04:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:17:13 UTC to 2016-09-30 05:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:37:13 UTC to 2016-09-30 05:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 05:57:13 UTC to 2016-09-30 05:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:17:13 UTC to 2016-09-30 06:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:37:13 UTC to 2016-09-30 06:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 06:57:13 UTC to 2016-09-30 06:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:17:13 UTC to 2016-09-30 07:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:37:13 UTC to 2016-09-30 07:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 07:57:13 UTC to 2016-09-30 07:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:17:13 UTC to 2016-09-30 08:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:37:13 UTC to 2016-09-30 08:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 08:57:13 UTC to 2016-09-30 08:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:17:13 UTC to 2016-09-30 09:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:37:13 UTC to 2016-09-30 09:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 09:57:13 UTC to 2016-09-30 09:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:17:13 UTC to 2016-09-30 10:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:37:13 UTC to 2016-09-30 10:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 10:57:13 UTC to 2016-09-30 10:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:17:13 UTC to 2016-09-30 11:17:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:37:13 UTC to 2016-09-30 11:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 11:57:13 UTC to 2016-09-30 11:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:17:12 UTC to 2016-09-30 12:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:37:13 UTC to 2016-09-30 12:37:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 12:57:13 UTC to 2016-09-30 12:57:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:17:12 UTC to 2016-09-30 13:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:37:12 UTC to 2016-09-30 13:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 13:57:12 UTC to 2016-09-30 13:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:17:12 UTC to 2016-09-30 14:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:37:12 UTC to 2016-09-30 14:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 14:57:12 UTC to 2016-09-30 14:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:17:12 UTC to 2016-09-30 15:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:37:12 UTC to 2016-09-30 15:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 15:57:12 UTC to 2016-09-30 15:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:17:12 UTC to 2016-09-30 16:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:37:12 UTC to 2016-09-30 16:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 16:57:12 UTC to 2016-09-30 16:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:17:12 UTC to 2016-09-30 17:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:37:12 UTC to 2016-09-30 17:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 17:57:12 UTC to 2016-09-30 17:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:17:12 UTC to 2016-09-30 18:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:37:12 UTC to 2016-09-30 18:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 18:57:12 UTC to 2016-09-30 18:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:17:12 UTC to 2016-09-30 19:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:37:12 UTC to 2016-09-30 19:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 19:57:12 UTC to 2016-09-30 19:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:17:12 UTC to 2016-09-30 20:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:37:12 UTC to 2016-09-30 20:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 20:57:12 UTC to 2016-09-30 20:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:17:12 UTC to 2016-09-30 21:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:37:12 UTC to 2016-09-30 21:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 21:57:12 UTC to 2016-09-30 21:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:17:12 UTC to 2016-09-30 22:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:37:12 UTC to 2016-09-30 22:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 22:57:12 UTC to 2016-09-30 22:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:17:12 UTC to 2016-09-30 23:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:37:12 UTC to 2016-09-30 23:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-09-30 23:57:12 UTC to 2016-09-30 23:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:17:12 UTC to 2016-10-01 00:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:37:12 UTC to 2016-10-01 00:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 00:57:12 UTC to 2016-10-01 00:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:17:12 UTC to 2016-10-01 01:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:37:12 UTC to 2016-10-01 01:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 01:57:12 UTC to 2016-10-01 01:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:17:12 UTC to 2016-10-01 02:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:37:12 UTC to 2016-10-01 02:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 02:57:12 UTC to 2016-10-01 02:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:17:12 UTC to 2016-10-01 03:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:37:12 UTC to 2016-10-01 03:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 03:57:12 UTC to 2016-10-01 03:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:17:12 UTC to 2016-10-01 04:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:37:12 UTC to 2016-10-01 04:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 04:57:12 UTC to 2016-10-01 04:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:17:12 UTC to 2016-10-01 05:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:37:12 UTC to 2016-10-01 05:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 05:57:12 UTC to 2016-10-01 05:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:17:12 UTC to 2016-10-01 06:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:37:12 UTC to 2016-10-01 06:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 06:57:12 UTC to 2016-10-01 06:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:17:12 UTC to 2016-10-01 07:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:37:12 UTC to 2016-10-01 07:37:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 07:57:12 UTC to 2016-10-01 07:57:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-01 08:17:12 UTC to 2016-10-01 08:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-02 23:32:50 UTC to 2016-10-02 23:33:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-02 23:42:50 UTC to 2016-10-02 23:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:02:50 UTC to 2016-10-03 00:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:22:50 UTC to 2016-10-03 00:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:42:50 UTC to 2016-10-03 00:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:02:50 UTC to 2016-10-03 01:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:22:50 UTC to 2016-10-03 01:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:42:50 UTC to 2016-10-03 01:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:02:50 UTC to 2016-10-03 02:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:22:50 UTC to 2016-10-03 02:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:42:50 UTC to 2016-10-03 02:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:02:50 UTC to 2016-10-03 03:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:22:50 UTC to 2016-10-03 03:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:42:50 UTC to 2016-10-03 03:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:02:50 UTC to 2016-10-03 04:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:22:50 UTC to 2016-10-03 04:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:42:50 UTC to 2016-10-03 04:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:02:50 UTC to 2016-10-03 05:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:22:50 UTC to 2016-10-03 05:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:42:50 UTC to 2016-10-03 05:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:02:50 UTC to 2016-10-03 06:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:22:50 UTC to 2016-10-03 06:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:42:50 UTC to 2016-10-03 06:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:02:50 UTC to 2016-10-03 07:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:22:50 UTC to 2016-10-03 07:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:42:50 UTC to 2016-10-03 07:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:02:50 UTC to 2016-10-03 08:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:22:50 UTC to 2016-10-03 08:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:42:50 UTC to 2016-10-03 08:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:02:50 UTC to 2016-10-03 09:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:22:50 UTC to 2016-10-03 09:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:42:50 UTC to 2016-10-03 09:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:02:50 UTC to 2016-10-03 10:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:22:50 UTC to 2016-10-03 10:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:42:50 UTC to 2016-10-03 10:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:02:50 UTC to 2016-10-03 11:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:22:50 UTC to 2016-10-03 11:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:42:50 UTC to 2016-10-03 11:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:02:49 UTC to 2016-10-03 12:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:22:49 UTC to 2016-10-03 12:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:42:50 UTC to 2016-10-03 12:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:02:49 UTC to 2016-10-03 13:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:22:49 UTC to 2016-10-03 13:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:42:50 UTC to 2016-10-03 13:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:02:49 UTC to 2016-10-03 14:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:22:49 UTC to 2016-10-03 14:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:42:49 UTC to 2016-10-03 14:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:02:49 UTC to 2016-10-03 15:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:22:49 UTC to 2016-10-03 15:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:42:49 UTC to 2016-10-03 15:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:02:49 UTC to 2016-10-03 16:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:22:49 UTC to 2016-10-03 16:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:42:49 UTC to 2016-10-03 16:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:02:49 UTC to 2016-10-03 17:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:22:49 UTC to 2016-10-03 17:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:42:49 UTC to 2016-10-03 17:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:02:49 UTC to 2016-10-03 18:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:22:49 UTC to 2016-10-03 18:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:42:49 UTC to 2016-10-03 18:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:02:49 UTC to 2016-10-03 19:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:22:49 UTC to 2016-10-03 19:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:42:49 UTC to 2016-10-03 19:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:02:49 UTC to 2016-10-03 20:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:22:49 UTC to 2016-10-03 20:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:42:49 UTC to 2016-10-03 20:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:02:49 UTC to 2016-10-03 21:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:22:49 UTC to 2016-10-03 21:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:42:49 UTC to 2016-10-03 21:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:02:49 UTC to 2016-10-03 22:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:22:49 UTC to 2016-10-03 22:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:42:49 UTC to 2016-10-03 22:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 23:02:49 UTC to 2016-10-03 23:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 23:22:49 UTC to 2016-10-03 23:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:28:57 UTC to 2016-10-05 20:29:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:38:57 UTC to 2016-10-05 20:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:58:57 UTC to 2016-10-05 20:59:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:18:57 UTC to 2016-10-05 21:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:38:57 UTC to 2016-10-05 21:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:58:57 UTC to 2016-10-05 21:59:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:18:57 UTC to 2016-10-05 22:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:38:58 UTC to 2016-10-05 22:39:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:58:56 UTC to 2016-10-05 22:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:18:57 UTC to 2016-10-05 23:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:38:57 UTC to 2016-10-05 23:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:58:56 UTC to 2016-10-05 23:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:18:56 UTC to 2016-10-06 00:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:38:56 UTC to 2016-10-06 00:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:58:56 UTC to 2016-10-06 00:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:18:56 UTC to 2016-10-06 01:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:38:56 UTC to 2016-10-06 01:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:58:56 UTC to 2016-10-06 01:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:18:56 UTC to 2016-10-06 02:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:38:56 UTC to 2016-10-06 02:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:58:56 UTC to 2016-10-06 02:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 03:18:56 UTC to 2016-10-06 03:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 15:59:09 UTC to 2016-10-10 15:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:19:09 UTC to 2016-10-10 16:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:39:09 UTC to 2016-10-10 16:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:59:09 UTC to 2016-10-10 16:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:19:09 UTC to 2016-10-10 17:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:39:09 UTC to 2016-10-10 17:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:59:09 UTC to 2016-10-10 17:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:19:09 UTC to 2016-10-10 18:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:39:09 UTC to 2016-10-10 18:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:59:09 UTC to 2016-10-10 18:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:19:09 UTC to 2016-10-10 19:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:39:09 UTC to 2016-10-10 19:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:59:10 UTC to 2016-10-10 19:59:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 20:19:09 UTC to 2016-10-10 20:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 21:59:09 UTC to 2016-10-10 21:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 22:19:09 UTC to 2016-10-10 22:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 22:59:09 UTC to 2016-10-10 22:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:19:15 UTC to 2016-10-10 23:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:39:13 UTC to 2016-10-10 23:39:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:59:50 UTC to 2016-10-11 00:00:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:19:09 UTC to 2016-10-11 00:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:39:09 UTC to 2016-10-11 00:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:59:09 UTC to 2016-10-11 00:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:19:09 UTC to 2016-10-11 01:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:39:09 UTC to 2016-10-11 01:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:59:09 UTC to 2016-10-11 01:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:19:09 UTC to 2016-10-11 02:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:39:09 UTC to 2016-10-11 02:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:59:08 UTC to 2016-10-11 02:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:19:09 UTC to 2016-10-11 03:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:39:08 UTC to 2016-10-11 03:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:59:08 UTC to 2016-10-11 03:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:19:09 UTC to 2016-10-11 04:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:39:08 UTC to 2016-10-11 04:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:59:08 UTC to 2016-10-11 04:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:19:08 UTC to 2016-10-11 05:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:39:08 UTC to 2016-10-11 05:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:59:08 UTC to 2016-10-11 05:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:19:08 UTC to 2016-10-11 06:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:39:08 UTC to 2016-10-11 06:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:59:08 UTC to 2016-10-11 06:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:19:08 UTC to 2016-10-11 07:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:39:08 UTC to 2016-10-11 07:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:59:08 UTC to 2016-10-11 07:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:19:08 UTC to 2016-10-11 08:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:39:08 UTC to 2016-10-11 08:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:59:08 UTC to 2016-10-11 08:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:19:08 UTC to 2016-10-11 09:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:39:08 UTC to 2016-10-11 09:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:59:08 UTC to 2016-10-11 09:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:19:08 UTC to 2016-10-11 10:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:39:08 UTC to 2016-10-11 10:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:59:08 UTC to 2016-10-11 10:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:19:08 UTC to 2016-10-11 11:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:39:08 UTC to 2016-10-11 11:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:59:08 UTC to 2016-10-11 11:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:19:08 UTC to 2016-10-11 12:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:39:08 UTC to 2016-10-11 12:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:59:08 UTC to 2016-10-11 12:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:19:08 UTC to 2016-10-11 13:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:39:08 UTC to 2016-10-11 13:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:59:08 UTC to 2016-10-11 13:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:19:08 UTC to 2016-10-11 14:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:39:08 UTC to 2016-10-11 14:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:59:08 UTC to 2016-10-11 14:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:19:08 UTC to 2016-10-11 15:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:39:08 UTC to 2016-10-11 15:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:59:08 UTC to 2016-10-11 15:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:19:08 UTC to 2016-10-11 16:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:39:08 UTC to 2016-10-11 16:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:59:09 UTC to 2016-10-11 16:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:19:08 UTC to 2016-10-11 17:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:39:08 UTC to 2016-10-11 17:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:59:08 UTC to 2016-10-11 17:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:19:08 UTC to 2016-10-11 18:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:39:08 UTC to 2016-10-11 18:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:59:08 UTC to 2016-10-11 18:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:19:08 UTC to 2016-10-11 19:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:39:09 UTC to 2016-10-11 19:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:59:08 UTC to 2016-10-11 19:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:19:08 UTC to 2016-10-11 20:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:39:08 UTC to 2016-10-11 20:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:59:08 UTC to 2016-10-11 20:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-01 08:17:12 UTC to 2016-10-01 08:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-02 23:32:50 UTC to 2016-10-02 23:33:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-02 23:42:50 UTC to 2016-10-02 23:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:02:50 UTC to 2016-10-03 00:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:22:50 UTC to 2016-10-03 00:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:42:50 UTC to 2016-10-03 00:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:02:50 UTC to 2016-10-03 01:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:22:50 UTC to 2016-10-03 01:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:42:50 UTC to 2016-10-03 01:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:02:50 UTC to 2016-10-03 02:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:22:50 UTC to 2016-10-03 02:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:42:50 UTC to 2016-10-03 02:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:02:50 UTC to 2016-10-03 03:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:22:50 UTC to 2016-10-03 03:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:42:50 UTC to 2016-10-03 03:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:02:50 UTC to 2016-10-03 04:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:22:50 UTC to 2016-10-03 04:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:42:50 UTC to 2016-10-03 04:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:02:50 UTC to 2016-10-03 05:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:22:50 UTC to 2016-10-03 05:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:42:50 UTC to 2016-10-03 05:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:02:50 UTC to 2016-10-03 06:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:22:50 UTC to 2016-10-03 06:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:42:50 UTC to 2016-10-03 06:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:02:50 UTC to 2016-10-03 07:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:22:50 UTC to 2016-10-03 07:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:42:50 UTC to 2016-10-03 07:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:02:50 UTC to 2016-10-03 08:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:22:50 UTC to 2016-10-03 08:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:42:50 UTC to 2016-10-03 08:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:02:50 UTC to 2016-10-03 09:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:22:50 UTC to 2016-10-03 09:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:42:50 UTC to 2016-10-03 09:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:02:50 UTC to 2016-10-03 10:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:22:50 UTC to 2016-10-03 10:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:42:50 UTC to 2016-10-03 10:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:02:50 UTC to 2016-10-03 11:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:22:50 UTC to 2016-10-03 11:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:42:50 UTC to 2016-10-03 11:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:02:49 UTC to 2016-10-03 12:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:22:49 UTC to 2016-10-03 12:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:42:50 UTC to 2016-10-03 12:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:02:49 UTC to 2016-10-03 13:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:22:49 UTC to 2016-10-03 13:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:42:50 UTC to 2016-10-03 13:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:02:49 UTC to 2016-10-03 14:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:22:49 UTC to 2016-10-03 14:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:42:49 UTC to 2016-10-03 14:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:02:49 UTC to 2016-10-03 15:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:22:49 UTC to 2016-10-03 15:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:42:49 UTC to 2016-10-03 15:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:02:49 UTC to 2016-10-03 16:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:22:49 UTC to 2016-10-03 16:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:42:49 UTC to 2016-10-03 16:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:02:49 UTC to 2016-10-03 17:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:22:49 UTC to 2016-10-03 17:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:42:49 UTC to 2016-10-03 17:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:02:49 UTC to 2016-10-03 18:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:22:49 UTC to 2016-10-03 18:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:42:49 UTC to 2016-10-03 18:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:02:49 UTC to 2016-10-03 19:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:22:49 UTC to 2016-10-03 19:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:42:49 UTC to 2016-10-03 19:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:02:49 UTC to 2016-10-03 20:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:22:49 UTC to 2016-10-03 20:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:42:49 UTC to 2016-10-03 20:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:02:49 UTC to 2016-10-03 21:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:22:49 UTC to 2016-10-03 21:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:42:49 UTC to 2016-10-03 21:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:02:49 UTC to 2016-10-03 22:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:22:49 UTC to 2016-10-03 22:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:42:49 UTC to 2016-10-03 22:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 23:02:49 UTC to 2016-10-03 23:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 23:22:49 UTC to 2016-10-03 23:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:28:57 UTC to 2016-10-05 20:29:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:38:57 UTC to 2016-10-05 20:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:58:57 UTC to 2016-10-05 20:59:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:18:57 UTC to 2016-10-05 21:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:38:57 UTC to 2016-10-05 21:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:58:57 UTC to 2016-10-05 21:59:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:18:57 UTC to 2016-10-05 22:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:38:58 UTC to 2016-10-05 22:39:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:58:56 UTC to 2016-10-05 22:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:18:57 UTC to 2016-10-05 23:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:38:57 UTC to 2016-10-05 23:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:58:56 UTC to 2016-10-05 23:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:18:56 UTC to 2016-10-06 00:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:38:56 UTC to 2016-10-06 00:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:58:56 UTC to 2016-10-06 00:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:18:56 UTC to 2016-10-06 01:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:38:56 UTC to 2016-10-06 01:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:58:56 UTC to 2016-10-06 01:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:18:56 UTC to 2016-10-06 02:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:38:56 UTC to 2016-10-06 02:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:58:56 UTC to 2016-10-06 02:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 03:18:56 UTC to 2016-10-06 03:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 15:59:09 UTC to 2016-10-10 15:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:19:09 UTC to 2016-10-10 16:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:39:09 UTC to 2016-10-10 16:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:59:09 UTC to 2016-10-10 16:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:19:09 UTC to 2016-10-10 17:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:39:09 UTC to 2016-10-10 17:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:59:09 UTC to 2016-10-10 17:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:19:09 UTC to 2016-10-10 18:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:39:09 UTC to 2016-10-10 18:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:59:09 UTC to 2016-10-10 18:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:19:09 UTC to 2016-10-10 19:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:39:09 UTC to 2016-10-10 19:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:59:10 UTC to 2016-10-10 19:59:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 20:19:09 UTC to 2016-10-10 20:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 21:59:09 UTC to 2016-10-10 21:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 22:19:09 UTC to 2016-10-10 22:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 22:59:09 UTC to 2016-10-10 22:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:19:15 UTC to 2016-10-10 23:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:39:13 UTC to 2016-10-10 23:39:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:59:50 UTC to 2016-10-11 00:00:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:19:09 UTC to 2016-10-11 00:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:39:09 UTC to 2016-10-11 00:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:59:09 UTC to 2016-10-11 00:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:19:09 UTC to 2016-10-11 01:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:39:09 UTC to 2016-10-11 01:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:59:09 UTC to 2016-10-11 01:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:19:09 UTC to 2016-10-11 02:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:39:09 UTC to 2016-10-11 02:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:59:08 UTC to 2016-10-11 02:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:19:09 UTC to 2016-10-11 03:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:39:08 UTC to 2016-10-11 03:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:59:08 UTC to 2016-10-11 03:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:19:09 UTC to 2016-10-11 04:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:39:08 UTC to 2016-10-11 04:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:59:08 UTC to 2016-10-11 04:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:19:08 UTC to 2016-10-11 05:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:39:08 UTC to 2016-10-11 05:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:59:08 UTC to 2016-10-11 05:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:19:08 UTC to 2016-10-11 06:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:39:08 UTC to 2016-10-11 06:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:59:08 UTC to 2016-10-11 06:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:19:08 UTC to 2016-10-11 07:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:39:08 UTC to 2016-10-11 07:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:59:08 UTC to 2016-10-11 07:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:19:08 UTC to 2016-10-11 08:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:39:08 UTC to 2016-10-11 08:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:59:08 UTC to 2016-10-11 08:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:19:08 UTC to 2016-10-11 09:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:39:08 UTC to 2016-10-11 09:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:59:08 UTC to 2016-10-11 09:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:19:08 UTC to 2016-10-11 10:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:39:08 UTC to 2016-10-11 10:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:59:08 UTC to 2016-10-11 10:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:19:08 UTC to 2016-10-11 11:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:39:08 UTC to 2016-10-11 11:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:59:08 UTC to 2016-10-11 11:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:19:08 UTC to 2016-10-11 12:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:39:08 UTC to 2016-10-11 12:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:59:08 UTC to 2016-10-11 12:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:19:08 UTC to 2016-10-11 13:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:39:08 UTC to 2016-10-11 13:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:59:08 UTC to 2016-10-11 13:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:19:08 UTC to 2016-10-11 14:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:39:08 UTC to 2016-10-11 14:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:59:08 UTC to 2016-10-11 14:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:19:08 UTC to 2016-10-11 15:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:39:08 UTC to 2016-10-11 15:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:59:08 UTC to 2016-10-11 15:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:19:08 UTC to 2016-10-11 16:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:39:08 UTC to 2016-10-11 16:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:59:09 UTC to 2016-10-11 16:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:19:08 UTC to 2016-10-11 17:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:39:08 UTC to 2016-10-11 17:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:59:08 UTC to 2016-10-11 17:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:19:08 UTC to 2016-10-11 18:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:39:08 UTC to 2016-10-11 18:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:59:08 UTC to 2016-10-11 18:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:19:08 UTC to 2016-10-11 19:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:39:09 UTC to 2016-10-11 19:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:59:08 UTC to 2016-10-11 19:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:19:08 UTC to 2016-10-11 20:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:39:08 UTC to 2016-10-11 20:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:59:08 UTC to 2016-10-11 20:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-01 08:17:12 UTC to 2016-10-01 08:17:32 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-02 23:32:50 UTC to 2016-10-02 23:33:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-02 23:42:50 UTC to 2016-10-02 23:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:02:50 UTC to 2016-10-03 00:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:22:50 UTC to 2016-10-03 00:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 00:42:50 UTC to 2016-10-03 00:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:02:50 UTC to 2016-10-03 01:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:22:50 UTC to 2016-10-03 01:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 01:42:50 UTC to 2016-10-03 01:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:02:50 UTC to 2016-10-03 02:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:22:50 UTC to 2016-10-03 02:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 02:42:50 UTC to 2016-10-03 02:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:02:50 UTC to 2016-10-03 03:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:22:50 UTC to 2016-10-03 03:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 03:42:50 UTC to 2016-10-03 03:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:02:50 UTC to 2016-10-03 04:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:22:50 UTC to 2016-10-03 04:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 04:42:50 UTC to 2016-10-03 04:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:02:50 UTC to 2016-10-03 05:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:22:50 UTC to 2016-10-03 05:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 05:42:50 UTC to 2016-10-03 05:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:02:50 UTC to 2016-10-03 06:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:22:50 UTC to 2016-10-03 06:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 06:42:50 UTC to 2016-10-03 06:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:02:50 UTC to 2016-10-03 07:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:22:50 UTC to 2016-10-03 07:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 07:42:50 UTC to 2016-10-03 07:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:02:50 UTC to 2016-10-03 08:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:22:50 UTC to 2016-10-03 08:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 08:42:50 UTC to 2016-10-03 08:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:02:50 UTC to 2016-10-03 09:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:22:50 UTC to 2016-10-03 09:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 09:42:50 UTC to 2016-10-03 09:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:02:50 UTC to 2016-10-03 10:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:22:50 UTC to 2016-10-03 10:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 10:42:50 UTC to 2016-10-03 10:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:02:50 UTC to 2016-10-03 11:03:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:22:50 UTC to 2016-10-03 11:23:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 11:42:50 UTC to 2016-10-03 11:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:02:49 UTC to 2016-10-03 12:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:22:49 UTC to 2016-10-03 12:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 12:42:50 UTC to 2016-10-03 12:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:02:49 UTC to 2016-10-03 13:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:22:49 UTC to 2016-10-03 13:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 13:42:50 UTC to 2016-10-03 13:43:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:02:49 UTC to 2016-10-03 14:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:22:49 UTC to 2016-10-03 14:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 14:42:49 UTC to 2016-10-03 14:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:02:49 UTC to 2016-10-03 15:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:22:49 UTC to 2016-10-03 15:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 15:42:49 UTC to 2016-10-03 15:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:02:49 UTC to 2016-10-03 16:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:22:49 UTC to 2016-10-03 16:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 16:42:49 UTC to 2016-10-03 16:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:02:49 UTC to 2016-10-03 17:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:22:49 UTC to 2016-10-03 17:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 17:42:49 UTC to 2016-10-03 17:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:02:49 UTC to 2016-10-03 18:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:22:49 UTC to 2016-10-03 18:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 18:42:49 UTC to 2016-10-03 18:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:02:49 UTC to 2016-10-03 19:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:22:49 UTC to 2016-10-03 19:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 19:42:49 UTC to 2016-10-03 19:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:02:49 UTC to 2016-10-03 20:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:22:49 UTC to 2016-10-03 20:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 20:42:49 UTC to 2016-10-03 20:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:02:49 UTC to 2016-10-03 21:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:22:49 UTC to 2016-10-03 21:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 21:42:49 UTC to 2016-10-03 21:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:02:49 UTC to 2016-10-03 22:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:22:49 UTC to 2016-10-03 22:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 22:42:49 UTC to 2016-10-03 22:43:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 23:02:49 UTC to 2016-10-03 23:03:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-03 23:22:49 UTC to 2016-10-03 23:23:09 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:28:57 UTC to 2016-10-05 20:29:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:38:57 UTC to 2016-10-05 20:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 20:58:57 UTC to 2016-10-05 20:59:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:18:57 UTC to 2016-10-05 21:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:38:57 UTC to 2016-10-05 21:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 21:58:57 UTC to 2016-10-05 21:59:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:18:57 UTC to 2016-10-05 22:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:38:58 UTC to 2016-10-05 22:39:18 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 22:58:56 UTC to 2016-10-05 22:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:18:57 UTC to 2016-10-05 23:19:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:38:57 UTC to 2016-10-05 23:39:17 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-05 23:58:56 UTC to 2016-10-05 23:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:18:56 UTC to 2016-10-06 00:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:38:56 UTC to 2016-10-06 00:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 00:58:56 UTC to 2016-10-06 00:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:18:56 UTC to 2016-10-06 01:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:38:56 UTC to 2016-10-06 01:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 01:58:56 UTC to 2016-10-06 01:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:18:56 UTC to 2016-10-06 02:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:38:56 UTC to 2016-10-06 02:39:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 02:58:56 UTC to 2016-10-06 02:59:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-06 03:18:56 UTC to 2016-10-06 03:19:16 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 15:59:09 UTC to 2016-10-10 15:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:19:09 UTC to 2016-10-10 16:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:39:09 UTC to 2016-10-10 16:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 16:59:09 UTC to 2016-10-10 16:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:19:09 UTC to 2016-10-10 17:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:39:09 UTC to 2016-10-10 17:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 17:59:09 UTC to 2016-10-10 17:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:19:09 UTC to 2016-10-10 18:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:39:09 UTC to 2016-10-10 18:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 18:59:09 UTC to 2016-10-10 18:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:19:09 UTC to 2016-10-10 19:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:39:09 UTC to 2016-10-10 19:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 19:59:10 UTC to 2016-10-10 19:59:30 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 20:19:09 UTC to 2016-10-10 20:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 21:59:09 UTC to 2016-10-10 21:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 22:19:09 UTC to 2016-10-10 22:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 22:59:09 UTC to 2016-10-10 22:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:19:15 UTC to 2016-10-10 23:19:35 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:39:13 UTC to 2016-10-10 23:39:33 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-10 23:59:50 UTC to 2016-10-11 00:00:10 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:19:09 UTC to 2016-10-11 00:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:39:09 UTC to 2016-10-11 00:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 00:59:09 UTC to 2016-10-11 00:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:19:09 UTC to 2016-10-11 01:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:39:09 UTC to 2016-10-11 01:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 01:59:09 UTC to 2016-10-11 01:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:19:09 UTC to 2016-10-11 02:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:39:09 UTC to 2016-10-11 02:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 02:59:08 UTC to 2016-10-11 02:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:19:09 UTC to 2016-10-11 03:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:39:08 UTC to 2016-10-11 03:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 03:59:08 UTC to 2016-10-11 03:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:19:09 UTC to 2016-10-11 04:19:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:39:08 UTC to 2016-10-11 04:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 04:59:08 UTC to 2016-10-11 04:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:19:08 UTC to 2016-10-11 05:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:39:08 UTC to 2016-10-11 05:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 05:59:08 UTC to 2016-10-11 05:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:19:08 UTC to 2016-10-11 06:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:39:08 UTC to 2016-10-11 06:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 06:59:08 UTC to 2016-10-11 06:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:19:08 UTC to 2016-10-11 07:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:39:08 UTC to 2016-10-11 07:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 07:59:08 UTC to 2016-10-11 07:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:19:08 UTC to 2016-10-11 08:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:39:08 UTC to 2016-10-11 08:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 08:59:08 UTC to 2016-10-11 08:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:19:08 UTC to 2016-10-11 09:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:39:08 UTC to 2016-10-11 09:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 09:59:08 UTC to 2016-10-11 09:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:19:08 UTC to 2016-10-11 10:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:39:08 UTC to 2016-10-11 10:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 10:59:08 UTC to 2016-10-11 10:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:19:08 UTC to 2016-10-11 11:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:39:08 UTC to 2016-10-11 11:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 11:59:08 UTC to 2016-10-11 11:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:19:08 UTC to 2016-10-11 12:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:39:08 UTC to 2016-10-11 12:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 12:59:08 UTC to 2016-10-11 12:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:19:08 UTC to 2016-10-11 13:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:39:08 UTC to 2016-10-11 13:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 13:59:08 UTC to 2016-10-11 13:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:19:08 UTC to 2016-10-11 14:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:39:08 UTC to 2016-10-11 14:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 14:59:08 UTC to 2016-10-11 14:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:19:08 UTC to 2016-10-11 15:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:39:08 UTC to 2016-10-11 15:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 15:59:08 UTC to 2016-10-11 15:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:19:08 UTC to 2016-10-11 16:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:39:08 UTC to 2016-10-11 16:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 16:59:09 UTC to 2016-10-11 16:59:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:19:08 UTC to 2016-10-11 17:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:39:08 UTC to 2016-10-11 17:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 17:59:08 UTC to 2016-10-11 17:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:19:08 UTC to 2016-10-11 18:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:39:08 UTC to 2016-10-11 18:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 18:59:08 UTC to 2016-10-11 18:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:19:08 UTC to 2016-10-11 19:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:39:09 UTC to 2016-10-11 19:39:29 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 19:59:08 UTC to 2016-10-11 19:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:19:08 UTC to 2016-10-11 20:19:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:39:08 UTC to 2016-10-11 20:39:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data with values less than False, during the time period from 2016-10-11 20:59:08 UTC to 2016-10-11 20:59:28 UTC flagged bad (pump flow from the immediately preceding water sample from 35 m depth did not consistently cut off immediately, causing intermittent contamination of the 1 m sample immediately following the 35 m sample. All of these points are flagged bad whether or not contamination was detected.) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2010-10-15 21:20:28.999996 UTC to 2010-10-15 21:20:39.000002 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:31.999999 UTC to 2011-07-01 19:01:32.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:31.999999 UTC to 2011-07-01 19:01:32.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-05-02 08:53:51.999998 UTC to 2011-05-02 08:53:51.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-05-13 15:08:01.999994 UTC to 2011-05-13 15:08:01.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-06-03 21:42:21.000001 UTC to 2011-06-03 21:42:21.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:26.000002 UTC to 2012-04-25 00:05:33.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-12 20:36:10.999989 UTC to 2012-10-12 20:36:20.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:26.000002 UTC to 2012-04-25 00:05:33.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-12 20:36:10.999989 UTC to 2012-10-12 20:36:20.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-07-15 00:23:21.999993 UTC to 2013-07-16 17:44:17.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-10-04 13:21:20.999992 UTC to 2013-10-04 16:47:21 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-06-22 06:01:06.999992 UTC to 2014-06-26 20:31:03 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-06-22 06:01:06.999992 UTC to 2014-06-26 20:31:03 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-05-24 22:10:02.999998 UTC to 2015-05-24 23:46:19.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-05-31 09:00:15.999997 UTC to 2015-05-31 09:00:15.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-20 20:33:20.000001 UTC to 2015-06-20 20:33:20.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-07-02 18:41:34.999999 UTC to 2015-07-02 18:41:34.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-08-09 12:08:25 UTC to 2015-08-09 12:08:25 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-28 19:40:51.999997 UTC to 2015-08-28 19:40:51.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-18 17:20:14 UTC to 2016-06-18 17:20:14 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-24 14:05:13.999993 UTC to 2016-07-24 14:05:13.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-18 17:20:14 UTC to 2016-06-18 17:20:14 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-24 14:05:13.999993 UTC to 2016-07-24 14:05:13.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-05-31 21:35:23.999999 UTC to 2017-05-31 21:35:23.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-06-01 08:49:23.999993 UTC to 2017-06-01 08:49:23.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-03 15:45:23.999994 UTC to 2017-06-03 15:45:23.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-07 13:33:23.999993 UTC to 2017-06-07 13:33:23.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-07 14:23:23.999995 UTC to 2017-06-07 14:23:23.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-11 13:41:23.999995 UTC to 2017-06-11 13:41:23.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-12 09:59:23.999994 UTC to 2017-06-12 09:59:23.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-19 14:45:23.999997 UTC to 2017-06-19 14:47:24 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-21 20:23:23.999995 UTC to 2017-06-21 20:23:23.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-05-31 21:35:23.999999 UTC to 2017-05-31 21:35:23.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-06-01 08:49:23.999993 UTC to 2017-06-01 08:49:23.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-03 15:45:23.999994 UTC to 2017-06-03 15:45:23.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-07 13:33:23.999993 UTC to 2017-06-07 13:33:23.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-07 14:23:23.999995 UTC to 2017-06-07 14:23:23.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-11 13:41:23.999995 UTC to 2017-06-11 13:41:23.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-12 09:59:23.999994 UTC to 2017-06-12 09:59:23.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-19 14:45:23.999997 UTC to 2017-06-19 14:47:24 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-21 20:23:23.999995 UTC to 2017-06-21 20:23:23.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-16 16:47:19 UTC to 2019-05-16 16:47:19 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-16 18:57:18.999998 UTC to 2019-05-16 18:57:18.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-17 12:31:19.000001 UTC to 2019-05-17 12:31:19.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-22 02:01:19.000001 UTC to 2019-05-22 02:01:19.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-22 02:33:18.999997 UTC to 2019-05-22 02:33:18.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-22 03:13:18.999995 UTC to 2019-05-22 03:13:18.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-22 05:31:18.999994 UTC to 2019-05-22 05:31:18.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-23 11:59:18.999994 UTC to 2019-05-23 11:59:18.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-06-17 23:01:19.000001 UTC to 2019-06-17 23:01:19.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-06-28 00:17:19 UTC to 2019-06-28 00:17:19 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-10 04:49:18.999993 UTC to 2019-07-10 04:49:18.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-10 12:21:18.999996 UTC to 2019-07-10 12:21:18.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-11 21:11:18.999992 UTC to 2019-07-11 21:11:18.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-08-05 04:25:18.999999 UTC to 2019-08-05 04:25:18.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-05 08:35:19 UTC to 2019-08-05 08:35:19 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-06 08:59:18.999994 UTC to 2019-08-06 08:59:18.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-18 16:45:18.999998 UTC to 2019-08-18 16:45:18.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-21 05:25:18.999995 UTC to 2019-08-21 05:25:18.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-21 15:17:19 UTC to 2019-08-21 15:17:19 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-22 11:47:18.999997 UTC to 2019-08-22 11:47:18.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-15 00:08:38.999995 UTC to 2022-06-15 00:08:38.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-17 14:16:38.999999 UTC to 2022-06-17 14:16:38.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-02 01:41:38.999994 UTC to 2022-07-02 01:41:38.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-22 14:55:39.000001 UTC to 2022-07-22 14:55:39.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-24 05:49:38.999992 UTC to 2022-07-24 05:49:38.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-15 00:08:38.999995 UTC to 2022-06-15 00:08:38.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-17 14:16:38.999999 UTC to 2022-06-17 14:16:38.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-02 01:41:38.999994 UTC to 2022-07-02 01:41:38.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-22 14:55:39.000001 UTC to 2022-07-22 14:55:39.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-07-24 05:49:38.999992 UTC to 2022-07-24 05:49:38.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-07-06 18:15:00 UTC to 2016-07-06 18:50:00 UTC flagged bad (spike of bad data across all depths) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2010-07-11 07:19:35.999998 UTC to 2010-07-11 07:19:35.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2010-07-11 08:05:35.999995 UTC to 2010-07-11 08:05:35.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2010-10-12 05:44:26.999995 UTC to 2010-10-12 05:44:26.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2010-10-14 23:16:31.999997 UTC to 2010-10-14 23:16:31.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2010-10-15 00:08:31.999992 UTC to 2010-10-15 00:08:31.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2010-10-15 08:02:33.000002 UTC to 2010-10-15 08:02:33.000002 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-05-01 21:09:52.999995 UTC to 2011-05-01 21:09:52.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-05-02 08:53:52.999992 UTC to 2011-05-02 08:53:52.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:32.999994 UTC to 2011-07-01 19:01:34.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:32.999994 UTC to 2011-07-01 19:01:34.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:24.999997 UTC to 2012-04-25 00:05:14 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-07-30 03:47:20.999993 UTC to 2012-07-30 03:47:20.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-07-30 03:47:20.999993 UTC to 2012-07-30 03:47:20.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:24.999997 UTC to 2012-04-25 00:05:14 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-07-15 15:34:08.999994 UTC to 2013-07-16 17:44:11.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2013-07-20 19:04:20.999992 UTC to 2013-07-20 19:04:20.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-10-04 13:21:14.999994 UTC to 2013-10-04 16:47:17.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-09-21 23:33:54.999993 UTC to 2014-09-21 23:34:04.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-09-21 23:33:54.999993 UTC to 2014-09-21 23:34:04.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-05-24 22:09:59 UTC to 2015-05-24 23:47:59.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-05-25 00:19:58.999998 UTC to 2015-05-25 00:19:58.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-05-25 15:44:01.000002 UTC to 2015-05-25 15:44:01.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-05-29 12:14:08 UTC to 2015-05-29 12:14:08 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-20 20:33:22.000001 UTC to 2015-06-20 20:33:22.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-08-09 16:58:28.999997 UTC to 2015-08-09 16:58:28.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-09 17:04:28.999996 UTC to 2015-08-09 17:04:28.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-04 19:06:01.999998 UTC to 2016-06-04 19:06:01.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-11 23:51:01.999995 UTC to 2016-07-11 23:51:01.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-12 04:36:02.000001 UTC to 2016-07-12 04:36:02.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-12 15:56:01.999993 UTC to 2016-07-12 15:56:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-15 15:16:01.999996 UTC to 2016-07-15 15:16:01.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-17 10:26:01.999997 UTC to 2016-07-17 10:26:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-18 15:56:01.999993 UTC to 2016-07-18 15:56:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-24 14:06:01.999995 UTC to 2016-07-24 14:06:01.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-26 13:46:01.999996 UTC to 2016-07-26 13:46:01.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-27 18:21:01.999998 UTC to 2016-07-27 18:21:01.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-29 19:21:01.999995 UTC to 2016-07-29 19:21:01.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-09-15 17:16:01.999999 UTC to 2016-09-15 17:16:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-09-21 07:01:01.999996 UTC to 2016-09-21 07:01:01.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-04 19:06:01.999998 UTC to 2016-06-04 19:06:01.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-11 23:51:01.999995 UTC to 2016-07-11 23:51:01.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-12 04:36:02.000001 UTC to 2016-07-12 04:36:02.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-12 15:56:01.999993 UTC to 2016-07-12 15:56:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-15 15:16:01.999996 UTC to 2016-07-15 15:16:01.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-17 10:26:01.999997 UTC to 2016-07-17 10:26:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-18 15:56:01.999993 UTC to 2016-07-18 15:56:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-24 14:06:01.999995 UTC to 2016-07-24 14:06:01.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-26 13:46:01.999996 UTC to 2016-07-26 13:46:01.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-27 18:21:01.999998 UTC to 2016-07-27 18:21:01.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-29 19:21:01.999995 UTC to 2016-07-29 19:21:01.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-09-15 17:16:01.999999 UTC to 2016-09-15 17:16:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-09-21 07:01:01.999996 UTC to 2016-09-21 07:01:01.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-05-27 15:57:37.000001 UTC to 2017-05-27 15:57:37.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-06-08 18:41:36.999998 UTC to 2017-06-08 18:41:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-20 10:09:36.999998 UTC to 2017-06-20 10:09:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-21 18:05:36.999996 UTC to 2017-06-21 18:05:36.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-24 15:55:36.999998 UTC to 2017-06-24 15:55:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-27 17:59:36.999997 UTC to 2017-06-27 17:59:36.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-30 17:13:37.000001 UTC to 2017-06-30 17:13:37.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-07-06 21:59:36.999994 UTC to 2017-07-06 21:59:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-07 00:57:37.000001 UTC to 2017-07-07 00:57:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-10 13:27:36.999994 UTC to 2017-07-10 13:27:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-15 14:11:36.999998 UTC to 2017-07-15 14:11:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-18 08:25:36.999998 UTC to 2017-07-18 08:25:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-26 11:03:36.999996 UTC to 2017-07-26 11:03:36.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-26 12:01:37 UTC to 2017-07-26 12:01:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-26 13:41:36.999995 UTC to 2017-07-26 13:41:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-29 05:49:36.999993 UTC to 2017-07-29 05:49:36.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-08-02 02:35:36.999993 UTC to 2017-08-02 02:35:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-05 17:59:36.999997 UTC to 2017-08-05 17:59:36.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-05 19:33:36.999993 UTC to 2017-08-05 19:33:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 00:57:37.000001 UTC to 2017-08-06 00:57:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 14:43:36.999994 UTC to 2017-08-06 14:43:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-15 15:37:36.999992 UTC to 2017-08-15 15:37:36.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-21 16:13:36.999994 UTC to 2017-08-21 16:13:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-22 19:09:36.999998 UTC to 2017-08-22 19:09:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-22 22:35:36.999996 UTC to 2017-08-22 22:35:36.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-26 06:23:36.999992 UTC to 2017-08-26 06:23:36.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-30 11:49:36.999993 UTC to 2017-08-30 11:49:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-30 15:45:36.999994 UTC to 2017-08-30 15:45:36.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-09-03 03:13:36.999998 UTC to 2017-09-03 03:13:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-07 13:17:37 UTC to 2017-09-07 13:17:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-07 23:41:37.000001 UTC to 2017-09-07 23:41:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-10 22:59:37.000001 UTC to 2017-09-10 22:59:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-11 09:31:36.999994 UTC to 2017-09-11 09:31:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-12 17:35:36.999993 UTC to 2017-09-12 17:35:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-19 02:09:36.999995 UTC to 2017-09-19 02:09:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-22 15:49:37 UTC to 2017-09-22 15:49:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-22 17:15:36.999994 UTC to 2017-09-22 17:15:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-22 23:17:36.999997 UTC to 2017-09-22 23:19:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-23 00:31:36.999994 UTC to 2017-09-23 00:31:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-23 05:43:36.999994 UTC to 2017-09-23 05:43:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-25 22:59:37.000001 UTC to 2017-09-25 22:59:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-26 21:17:36.999993 UTC to 2017-09-26 21:17:36.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-15 06:29:37.000001 UTC to 2017-10-15 06:29:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-15 06:53:36.999995 UTC to 2017-10-15 06:53:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-15 08:45:36.999997 UTC to 2017-10-15 08:45:36.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-16 16:51:36.999999 UTC to 2017-10-16 16:51:36.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-16 16:59:37.000001 UTC to 2017-10-16 16:59:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-18 12:35:36.999999 UTC to 2017-10-18 12:35:36.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-18 12:53:36.999995 UTC to 2017-10-18 12:53:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-20 14:13:37.000001 UTC to 2017-10-20 14:13:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-05-27 15:57:37.000001 UTC to 2017-05-27 15:57:37.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-06-08 18:41:36.999998 UTC to 2017-06-08 18:41:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-20 10:09:36.999998 UTC to 2017-06-20 10:09:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-21 18:05:36.999996 UTC to 2017-06-21 18:05:36.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-24 15:55:36.999998 UTC to 2017-06-24 15:55:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-27 17:59:36.999997 UTC to 2017-06-27 17:59:36.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-30 17:13:37.000001 UTC to 2017-06-30 17:13:37.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-07-06 21:59:36.999994 UTC to 2017-07-06 21:59:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-07 00:57:37.000001 UTC to 2017-07-07 00:57:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-10 13:27:36.999994 UTC to 2017-07-10 13:27:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-15 14:11:36.999998 UTC to 2017-07-15 14:11:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-18 08:25:36.999998 UTC to 2017-07-18 08:25:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-26 11:03:36.999996 UTC to 2017-07-26 11:03:36.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-26 12:01:37 UTC to 2017-07-26 12:01:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-26 13:41:36.999995 UTC to 2017-07-26 13:41:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-07-29 05:49:36.999993 UTC to 2017-07-29 05:49:36.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-08-02 02:35:36.999993 UTC to 2017-08-02 02:35:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-05 17:59:36.999997 UTC to 2017-08-05 17:59:36.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-05 19:33:36.999993 UTC to 2017-08-05 19:33:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 00:57:37.000001 UTC to 2017-08-06 00:57:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 14:43:36.999994 UTC to 2017-08-06 14:43:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-15 15:37:36.999992 UTC to 2017-08-15 15:37:36.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-21 16:13:36.999994 UTC to 2017-08-21 16:13:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-22 19:09:36.999998 UTC to 2017-08-22 19:09:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-22 22:35:36.999996 UTC to 2017-08-22 22:35:36.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-26 06:23:36.999992 UTC to 2017-08-26 06:23:36.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-30 11:49:36.999993 UTC to 2017-08-30 11:49:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-30 15:45:36.999994 UTC to 2017-08-30 15:45:36.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-09-03 03:13:36.999998 UTC to 2017-09-03 03:13:36.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-07 13:17:37 UTC to 2017-09-07 13:17:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-07 23:41:37.000001 UTC to 2017-09-07 23:41:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-10 22:59:37.000001 UTC to 2017-09-10 22:59:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-11 09:31:36.999994 UTC to 2017-09-11 09:31:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-12 17:35:36.999993 UTC to 2017-09-12 17:35:36.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-19 02:09:36.999995 UTC to 2017-09-19 02:09:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-22 15:49:37 UTC to 2017-09-22 15:49:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-22 17:15:36.999994 UTC to 2017-09-22 17:15:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-22 23:17:36.999997 UTC to 2017-09-22 23:19:37 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-23 00:31:36.999994 UTC to 2017-09-23 00:31:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-23 05:43:36.999994 UTC to 2017-09-23 05:43:36.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-25 22:59:37.000001 UTC to 2017-09-25 22:59:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-26 21:17:36.999993 UTC to 2017-09-26 21:17:36.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-15 06:29:37.000001 UTC to 2017-10-15 06:29:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-15 06:53:36.999995 UTC to 2017-10-15 06:53:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-15 08:45:36.999997 UTC to 2017-10-15 08:45:36.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-16 16:51:36.999999 UTC to 2017-10-16 16:51:36.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-16 16:59:37.000001 UTC to 2017-10-16 16:59:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-18 12:35:36.999999 UTC to 2017-10-18 12:35:36.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-18 12:53:36.999995 UTC to 2017-10-18 12:53:36.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-20 14:13:37.000001 UTC to 2017-10-20 14:13:37.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-11 21:09:22.999997 UTC to 2019-07-11 21:09:22.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-08-27 18:51:22.999998 UTC to 2019-08-27 18:51:22.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-09-06 11:05:22.999995 UTC to 2019-09-06 11:05:22.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-09-11 02:41:22.999997 UTC to 2019-09-11 02:41:22.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-09-25 17:33:22.999995 UTC to 2019-09-25 17:33:22.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-09-26 02:55:22.999997 UTC to 2019-09-26 02:55:22.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-07-04 18:45:01.999993 UTC to 2021-07-30 18:51:02.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-05 06:07:01.999998 UTC to 2021-08-05 06:07:01.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 06:11:01.999993 UTC to 2021-08-05 06:11:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 06:15:01.999999 UTC to 2021-08-05 06:15:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-13 07:11:02 UTC to 2021-08-13 07:11:02 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-20 05:55:02 UTC to 2021-08-20 05:55:02 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-10-08 17:19:01.999998 UTC to 2021-10-08 20:37:01.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-08 20:39:01.999997 UTC to 2021-10-11 23:23:01.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-07-04 18:45:01.999993 UTC to 2021-07-30 18:51:02.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-05 06:07:01.999998 UTC to 2021-08-05 06:07:01.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 06:11:01.999993 UTC to 2021-08-05 06:11:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 06:15:01.999999 UTC to 2021-08-05 06:15:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-13 07:11:02 UTC to 2021-08-13 07:11:02 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-20 05:55:02 UTC to 2021-08-20 05:55:02 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-10-08 17:19:01.999998 UTC to 2021-10-08 20:37:01.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-08 20:39:01.999997 UTC to 2021-10-11 23:23:01.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-07-04 18:45:01.999993 UTC to 2021-07-30 18:51:02.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-05 06:07:01.999998 UTC to 2021-08-05 06:07:01.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 06:11:01.999993 UTC to 2021-08-05 06:11:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 06:15:01.999999 UTC to 2021-08-05 06:15:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-13 07:11:02 UTC to 2021-08-13 07:11:02 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-20 05:55:02 UTC to 2021-08-20 05:55:02 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-10-08 17:19:01.999998 UTC to 2021-10-08 20:37:01.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-10-08 20:39:01.999997 UTC to 2021-10-11 23:23:01.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-12 08:05:55.999997 UTC to 2022-06-12 08:06:55.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-12 08:05:55.999997 UTC to 2022-06-12 08:06:55.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-07-06 18:15:00 UTC to 2016-07-06 18:50:00 UTC flagged bad (spike of bad data across all depths) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 08:00:00 UTC to 2011-07-01 19:39:00 UTC flagged bad (Data from before buoy was fully deployed.) Data with values less than False, during the time period from 2011-07-01 18:40:02 UTC to 2011-07-01 20:35:02.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-19 10:30:01.999993 UTC to 2011-07-19 10:30:01.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 08:00:00 UTC to 2011-07-01 19:39:00 UTC flagged bad (Data from before buoy was fully deployed.) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 08:00:00 UTC to 2011-07-01 19:39:00 UTC flagged bad (Data from before buoy was fully deployed.) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-09-14 11:15:01.999993 UTC to 2011-09-14 11:15:01.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-20 19:16:15.999997 UTC to 2012-10-20 19:16:26.000003 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:10.999992 UTC to 2012-04-25 00:05:49.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-20 19:16:15.999997 UTC to 2012-10-20 19:16:26.000003 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:10.999992 UTC to 2012-04-25 00:05:49.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-07-14 21:07:15.999992 UTC to 2013-07-16 17:42:16.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-10-04 13:22:15.999995 UTC to 2013-10-08 20:43:41.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-06-22 06:01:01.999999 UTC to 2014-06-26 20:30:54.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-06-22 06:01:01.999999 UTC to 2014-06-26 20:30:54.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-05-24 22:09:55.999996 UTC to 2015-05-25 00:19:55.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-08-09 16:59:14.999999 UTC to 2015-08-09 16:59:14.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-10-07 19:00:00 UTC to 2015-10-08 23:00:00 UTC flagged bad (tail of data after buoy recovery) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-10-07 19:00:00 UTC to 2015-10-08 23:00:00 UTC flagged bad (tail of data after buoy recovery) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-10-07 19:00:00 UTC to 2015-10-08 23:00:00 UTC flagged bad (tail of data after buoy recovery) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-15 09:11:29.999992 UTC to 2016-07-15 09:11:29.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-15 15:16:29.999995 UTC to 2016-07-15 15:16:29.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-24 14:06:29.999994 UTC to 2016-07-24 14:06:29.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-15 09:11:29.999992 UTC to 2016-07-15 09:11:29.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-15 15:16:29.999995 UTC to 2016-07-15 15:16:29.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-07-24 14:06:29.999994 UTC to 2016-07-24 14:06:29.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-05-27 15:58:45.999999 UTC to 2017-05-27 15:58:45.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-06-10 21:10:46 UTC to 2017-06-10 21:10:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-11 20:30:45.999992 UTC to 2017-06-11 20:30:45.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-16 06:08:45.999997 UTC to 2017-06-16 06:08:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-17 12:44:45.999999 UTC to 2017-06-17 12:44:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-17 13:10:45.999996 UTC to 2017-06-17 13:10:45.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-19 00:12:45.999993 UTC to 2017-06-19 00:12:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-22 05:36:46.000001 UTC to 2017-06-22 05:36:46.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-22 06:00:45.999995 UTC to 2017-06-22 06:00:45.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-08-05 13:42:45.999993 UTC to 2017-08-05 13:42:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 05:20:45.999997 UTC to 2017-08-06 05:20:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 05:58:45.999992 UTC to 2017-08-06 05:58:45.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-07 05:06:45.999997 UTC to 2017-08-07 05:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-08 15:52:46 UTC to 2017-08-08 15:52:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-08 18:30:45.999999 UTC to 2017-08-08 18:30:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-08 21:20:45.999994 UTC to 2017-08-08 21:20:45.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-09 08:50:46.000001 UTC to 2017-08-09 08:50:46.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-16 13:30:45.999995 UTC to 2017-08-16 13:30:45.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-20 23:06:45.999997 UTC to 2017-08-20 23:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-22 19:08:45.999993 UTC to 2017-08-22 19:08:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-30 21:12:45.999993 UTC to 2017-08-30 21:12:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-31 01:06:46.000001 UTC to 2017-08-31 01:06:46.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-09-02 08:04:45.999994 UTC to 2017-09-02 08:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-08 11:22:46 UTC to 2017-09-08 11:22:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-10 19:08:45.999993 UTC to 2017-09-10 19:08:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-11 12:42:45.999996 UTC to 2017-09-11 12:42:45.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-13 02:56:45.999999 UTC to 2017-09-13 02:56:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-19 17:46:45.999995 UTC to 2017-09-19 17:48:45.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-27 00:48:45.999995 UTC to 2017-09-27 00:48:45.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-03 09:40:45.999993 UTC to 2017-10-03 09:40:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-04 00:20:45.999994 UTC to 2017-10-04 00:20:45.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-13 21:30:45.999999 UTC to 2017-10-13 21:30:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-14 05:34:45.999998 UTC to 2017-10-14 05:34:45.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-20 20:38:45.999993 UTC to 2017-10-20 20:38:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-21 02:02:46.000002 UTC to 2017-10-21 02:02:46.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-05-27 15:58:45.999999 UTC to 2017-05-27 15:58:45.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-06-10 21:10:46 UTC to 2017-06-10 21:10:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-11 20:30:45.999992 UTC to 2017-06-11 20:30:45.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-16 06:08:45.999997 UTC to 2017-06-16 06:08:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-17 12:44:45.999999 UTC to 2017-06-17 12:44:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-17 13:10:45.999996 UTC to 2017-06-17 13:10:45.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-19 00:12:45.999993 UTC to 2017-06-19 00:12:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-22 05:36:46.000001 UTC to 2017-06-22 05:36:46.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-22 06:00:45.999995 UTC to 2017-06-22 06:00:45.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-08-05 13:42:45.999993 UTC to 2017-08-05 13:42:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 05:20:45.999997 UTC to 2017-08-06 05:20:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-06 05:58:45.999992 UTC to 2017-08-06 05:58:45.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-07 05:06:45.999997 UTC to 2017-08-07 05:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-08 15:52:46 UTC to 2017-08-08 15:52:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-08 18:30:45.999999 UTC to 2017-08-08 18:30:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-08 21:20:45.999994 UTC to 2017-08-08 21:20:45.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-09 08:50:46.000001 UTC to 2017-08-09 08:50:46.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-16 13:30:45.999995 UTC to 2017-08-16 13:30:45.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-20 23:06:45.999997 UTC to 2017-08-20 23:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-22 19:08:45.999993 UTC to 2017-08-22 19:08:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-30 21:12:45.999993 UTC to 2017-08-30 21:12:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-08-31 01:06:46.000001 UTC to 2017-08-31 01:06:46.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-09-02 08:04:45.999994 UTC to 2017-09-02 08:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-08 11:22:46 UTC to 2017-09-08 11:22:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-10 19:08:45.999993 UTC to 2017-09-10 19:08:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-11 12:42:45.999996 UTC to 2017-09-11 12:42:45.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-13 02:56:45.999999 UTC to 2017-09-13 02:56:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-19 17:46:45.999995 UTC to 2017-09-19 17:48:45.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-09-27 00:48:45.999995 UTC to 2017-09-27 00:48:45.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-03 09:40:45.999993 UTC to 2017-10-03 09:40:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-04 00:20:45.999994 UTC to 2017-10-04 00:20:45.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-13 21:30:45.999999 UTC to 2017-10-13 21:30:45.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-14 05:34:45.999998 UTC to 2017-10-14 05:34:45.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-20 20:38:45.999993 UTC to 2017-10-20 20:38:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-21 02:02:46.000002 UTC to 2017-10-21 02:02:46.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-27 02:51:55.999993 UTC to 2019-05-27 02:51:55.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-11 21:09:55.999999 UTC to 2019-07-11 21:09:55.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-12 18:27:55.999995 UTC to 2019-07-12 18:27:55.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-28 06:57:55.999999 UTC to 2019-07-28 06:57:55.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-08-13 14:09:55.999993 UTC to 2019-08-13 14:09:55.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-27 18:51:56 UTC to 2019-08-27 18:51:56 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-27 02:51:55.999993 UTC to 2019-05-27 02:51:55.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-11 21:09:55.999999 UTC to 2019-07-11 21:09:55.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-12 18:27:55.999995 UTC to 2019-07-12 18:27:55.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-28 06:57:55.999999 UTC to 2019-07-28 06:57:55.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-08-13 14:09:55.999993 UTC to 2019-08-13 14:09:55.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-08-27 18:51:56 UTC to 2019-08-27 18:51:56 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-21 08:39:02.999992 UTC to 2021-08-21 08:39:02.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-03 08:40:02.999998 UTC to 2021-09-03 08:40:02.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-10 23:31:03 UTC to 2021-09-10 23:31:03 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-11 00:48:02.999996 UTC to 2021-09-11 00:50:02.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-13 13:22:02.999996 UTC to 2021-09-13 13:23:02.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-21 08:39:02.999992 UTC to 2021-08-21 08:39:02.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-03 08:40:02.999998 UTC to 2021-09-03 08:40:02.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-10 23:31:03 UTC to 2021-09-10 23:31:03 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-11 00:48:02.999996 UTC to 2021-09-11 00:50:02.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-09-13 13:22:02.999996 UTC to 2021-09-13 13:23:02.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-17 14:15:35.999999 UTC to 2022-06-17 14:15:35.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-14 23:57:36 UTC to 2022-07-14 23:57:36 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-11-01 11:42:35.999993 UTC to 2022-11-01 11:43:36 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-17 14:15:35.999999 UTC to 2022-06-17 14:15:35.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-14 23:57:36 UTC to 2022-07-14 23:57:36 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-11-01 11:42:35.999993 UTC to 2022-11-01 11:43:36 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-06-10 08:00:00 UTC to 2016-06-20 08:00:00 UTC flagged bad (spikes of bad data) Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-07-06 18:15:00 UTC to 2016-07-06 18:50:00 UTC flagged bad (spike of bad data across all depths) Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 40.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 40.0 preliminarily flagged bad 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-06-23 17:24:58.358094 UTC to 2011-06-23 17:25:08.3581 UTC flagged bad (prelim QC flag) 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-09-29 03:04:59.044489 UTC to 2011-09-29 03:05:09.044495 UTC flagged bad (prelim QC flag) 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-06-23 17:24:58.358094 UTC to 2011-06-23 17:25:08.3581 UTC flagged bad (prelim QC flag) 2014-11-14 10:21:07 oxygensat: 2013-07-19 15:25:30.000003-07 to 2013-07-19 15:45:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-14 15:24:40.999997-07 to 2013-07-16 19:45:29.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-31 02:35:28.999996-07 to 2013-07-31 02:35:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-31 02:15:30.000002-07 to 2013-07-31 02:15:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-30 14:45:30.000005-07 to 2013-07-30 15:05:30.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-07-30 14:45:30.000005-07 to 2013-07-30 15:05:30.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-31 02:15:30.000002-07 to 2013-07-31 02:15:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-19 15:25:30.000003-07 to 2013-07-19 15:45:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-14 15:24:40.999997-07 to 2013-07-16 19:45:29.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-31 02:35:28.999996-07 to 2013-07-31 02:35:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-07-14 21:24:40.999997 UTC to 2013-07-16 17:34:55.999994 UTC flagged bad (prelim QC flag) 2014-11-14 10:21:07 oxygensat: 2013-08-05 04:15:30.000005-07 to 2013-08-05 04:15:30.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-04 07:05:28.999996-07 to 2013-08-04 07:05:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-29 20:55:24.000002-07 to 2013-08-29 20:55:24.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-29 20:25:25.999998-07 to 2013-08-29 20:25:25.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-06 09:55:29.999996-07 to 2013-08-06 09:55:29.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-08-05 04:15:30.000005-07 to 2013-08-05 04:15:30.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-06 09:55:29.999996-07 to 2013-08-06 09:55:29.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-04 07:05:28.999996-07 to 2013-08-04 07:05:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-29 20:55:24.000002-07 to 2013-08-29 20:55:24.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-29 20:25:25.999998-07 to 2013-08-29 20:25:25.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-08-30 02:25:25.999998 UTC to 2013-08-30 02:25:25.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2013-08-30 02:55:23.999992 UTC to 2013-08-30 02:55:23.999992 UTC flagged bad (prelim QC flag) 2014-11-14 10:21:07 oxygensat: 2013-09-29 20:05:01.000004-07 to 2013-09-29 20:05:01.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-30 07:35:02.000005-07 to 2013-09-30 07:35:02.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-17 12:35:20.999996-07 to 2013-09-17 12:35:20.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 07:35:17.999998-07 to 2013-09-21 07:35:17.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 07:15:19.000004-07 to 2013-09-21 07:15:19.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 07:55:19.999997-07 to 2013-09-21 08:25:18.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 16:55:17.999997-07 to 2013-09-21 16:55:17.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-09-30 07:35:02.000005-07 to 2013-09-30 07:35:02.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 16:55:17.999997-07 to 2013-09-21 16:55:17.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 07:55:19.999997-07 to 2013-09-21 08:25:18.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 07:35:17.999998-07 to 2013-09-21 07:35:17.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 07:15:19.000004-07 to 2013-09-21 07:15:19.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-17 12:35:20.999996-07 to 2013-09-17 12:35:20.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-29 20:05:01.000004-07 to 2013-09-29 20:05:01.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2014-11-14 10:21:07 oxygensat: 2013-10-04 11:25:01.999997-07 to 2013-10-04 12:15:07.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-10-04 11:25:01.999997-07 to 2013-10-04 12:15:07.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-06-06 16:57:58.999989 UTC to 2012-06-06 16:58:08.999995 UTC flagged bad (prelim QC flag) 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2012-10-12 14:48:27 oxygensat: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2012-10-12 14:48:26 oxygen: 2011-04-01 01:00:00-07 to 2011-10-01 01:00:00-07: type: 3 value: 1.0 comment: 4/1/11 - 10/1/11: The sensor was newly calibrated and the calibration was checked and verified in March 2011 prior to deployment of the station mooring. It was checked again on 10/13/11 following recovery of the sensor. During both checks it was found to be within 1% of the YSI handheld optode. v1: 1.0 v2: 0.0 v3: 0.0 v4:0.0 reference_var: version: 1 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-09-29 03:04:59.044489 UTC to 2011-09-29 03:05:09.044495 UTC flagged bad (prelim QC flag) 2016-04-21 10:37:01 oxygensat: 2015-05-24 16:12:57-07 to 2015-05-24 18:22:58.000002-07: type: 1 value: 3.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2016-04-21 10:37:00 oxygen: 2015-05-24 16:12:57-07 to 2015-05-24 18:22:58.000002-07: type: 1 value: 3.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-05-24 22:12:57 UTC to 2015-05-25 00:22:57.999992 UTC flagged bad (prelim QC flag) 2016-04-21 10:37:01 oxygensat: 2015-06-20 11:52:44.999999-07 to 2015-06-20 14:02:57.999997-07: type: 1 value: 3.0 comment: predeployment tail of data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) 2016-04-21 10:37:00 oxygen: 2015-06-20 11:52:44.999999-07 to 2015-06-20 14:02:57.999997-07: type: 1 value: 3.0 comment: predeployment tail of data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-20 17:52:44.999999 UTC to 2015-06-20 20:02:57.999997 UTC flagged bad (prelim QC flag) 2016-04-21 10:37:01 oxygensat: 2015-07-23 21:13:08.999999-07 to 2015-07-23 21:13:08.999999-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-07-24 10:23:09-07 to 2015-07-24 10:23:09-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2016-04-21 10:37:00 oxygen: 2015-07-23 21:13:08.999999-07 to 2015-07-23 21:13:08.999999-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-07-24 10:23:09-07 to 2015-07-24 10:23:09-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2016-04-21 10:37:01 oxygensat: 2015-08-19 17:03:08.000003-07 to 2015-08-19 17:13:07.999997-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-08-18 19:33:08-07 to 2015-08-18 19:33:08-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-08-18 20:33:07.999996-07 to 2015-08-18 21:53:08.000002-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2016-04-21 10:37:00 oxygen: 2015-08-18 19:33:08-07 to 2015-08-18 19:33:08-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-08-18 20:33:07.999996-07 to 2015-08-18 21:53:08.000002-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-08-19 17:03:08.000003-07 to 2015-08-19 17:13:07.999997-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-03-25 21:20:19.999994 UTC to 2012-04-02 20:00:24.999992 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-03-25 21:20:19.999994 UTC to 2012-04-02 20:00:24.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2012-04-24 14:57:41.999997 UTC to 2012-04-24 17:37:52.999999 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-06-27 10:49:32.000003-07 to 2012-06-27 11:09:30.000003-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-06-27 10:49:32.000003-07 to 2012-06-27 11:09:30.000003-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-06-27 16:49:31.999993 UTC to 2012-06-27 16:59:20.999997 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-07-30 17:19:57.999996-07 to 2012-07-30 17:39:57.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-07-30 17:19:57.999996-07 to 2012-07-30 17:39:57.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-08-29 03:19:56.000004-07 to 2012-08-29 03:19:56.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-08-07 07:29:58.000004-07 to 2012-08-07 07:29:58.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-08-30 05:09:56.000003-07 to 2012-08-30 05:19:53.000003-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-08-29 03:19:56.000004-07 to 2012-08-29 03:19:56.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-08-30 05:09:56.000003-07 to 2012-08-30 05:19:53.000003-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-08-07 07:29:58.000004-07 to 2012-08-07 07:29:58.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-09-28 10:39:57.999999 UTC to 2012-09-28 10:39:57.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2012-09-28 10:59:56.999993 UTC to 2012-09-28 10:59:56.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2012-10-01 00:19:56.999998 UTC to 2012-10-01 00:19:56.999998 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-20 19:29:48.999993 UTC to 2012-10-21 13:49:27 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-06-26 18:36:40.999994 UTC to 2014-06-26 19:46:32.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-06-27 11:27:00.000001 UTC to 2014-06-27 11:36:54.999992 UTC flagged bad (prelim QC flag) 2014-11-26 09:32:09 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:47 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-26 09:32:08 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:46 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2014-11-26 09:32:09 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:47 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-26 09:32:08 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:46 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2018-04-25 10:55:47 oxygensat: 2014-09-14 11:16:55.999998-07 to 2014-09-14 11:16:55.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-26 09:32:09 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:47 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2018-04-25 10:55:46 oxygen: 2014-09-14 11:16:55.999998-07 to 2014-09-14 11:16:55.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-26 09:32:08 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:46 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-03-25 21:20:19.999994 UTC to 2012-04-02 20:00:24.999992 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-03-25 15:20:20.000004-07 to 2012-04-24 11:37:52.999999-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-03-25 21:20:19.999994 UTC to 2012-04-02 20:00:24.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2012-04-24 14:57:41.999997 UTC to 2012-04-24 17:37:52.999999 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-06-27 10:49:32.000003-07 to 2012-06-27 11:09:30.000003-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-06-27 10:49:32.000003-07 to 2012-06-27 11:09:30.000003-07: type: 1 value: 3.0 comment: Visually identified as aberrant data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-06-27 16:49:31.999993 UTC to 2012-06-27 16:59:20.999997 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-07-30 17:19:57.999996-07 to 2012-07-30 17:39:57.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-07-30 17:19:57.999996-07 to 2012-07-30 17:39:57.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-08-29 03:19:56.000004-07 to 2012-08-29 03:19:56.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-08-07 07:29:58.000004-07 to 2012-08-07 07:29:58.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-08-30 05:09:56.000003-07 to 2012-08-30 05:19:53.000003-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-08-29 03:19:56.000004-07 to 2012-08-29 03:19:56.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-08-30 05:09:56.000003-07 to 2012-08-30 05:19:53.000003-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-08-07 07:29:58.000004-07 to 2012-08-07 07:29:58.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-09-28 10:39:57.999999 UTC to 2012-09-28 10:39:57.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2012-09-28 10:59:56.999993 UTC to 2012-09-28 10:59:56.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2012-10-01 00:19:56.999998 UTC to 2012-10-01 00:19:56.999998 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-20 19:29:48.999993 UTC to 2012-10-21 13:49:27 UTC flagged bad (prelim QC flag) 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2013-05-08 16:19:16 oxygensat: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2013-05-08 16:19:15 oxygen: 2012-04-23 01:00:00-07 to 2012-10-22 01:00:00-07: type: 3 value: 21.0 comment: 4/23/12 - 10/22/12: This sensor was recovered in mid-June and the calibration was checked against several newly calibrated sensors and was found to be good. A post deployment check was not performed before the sensor was redeployed to SATURN-07 so the extent of drift and fouling cannot be determined. It is worth noting that while deployed at SATURN-07 this sensor had a fairly consistent offset of about 3.5% with the sensor at Saturn03 (with a verified calibration) during January 2013 indicating that sensor drift has not been extensive. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 2 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-06-06 16:57:58.999989 UTC to 2012-06-06 16:58:08.999995 UTC flagged bad (prelim QC flag) 2014-11-14 10:21:07 oxygensat: 2013-07-19 15:25:30.000003-07 to 2013-07-19 15:45:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-14 15:24:40.999997-07 to 2013-07-16 19:45:29.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-31 02:35:28.999996-07 to 2013-07-31 02:35:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-31 02:15:30.000002-07 to 2013-07-31 02:15:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-30 14:45:30.000005-07 to 2013-07-30 15:05:30.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-07-30 14:45:30.000005-07 to 2013-07-30 15:05:30.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-31 02:15:30.000002-07 to 2013-07-31 02:15:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-19 15:25:30.000003-07 to 2013-07-19 15:45:30.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-14 15:24:40.999997-07 to 2013-07-16 19:45:29.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-31 02:35:28.999996-07 to 2013-07-31 02:35:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-07-14 21:24:40.999997 UTC to 2013-07-16 17:34:55.999994 UTC flagged bad (prelim QC flag) 2014-11-14 10:21:07 oxygensat: 2013-08-05 04:15:30.000005-07 to 2013-08-05 04:15:30.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-04 07:05:28.999996-07 to 2013-08-04 07:05:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-29 20:55:24.000002-07 to 2013-08-29 20:55:24.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-29 20:25:25.999998-07 to 2013-08-29 20:25:25.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-08-06 09:55:29.999996-07 to 2013-08-06 09:55:29.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-08-05 04:15:30.000005-07 to 2013-08-05 04:15:30.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-06 09:55:29.999996-07 to 2013-08-06 09:55:29.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-04 07:05:28.999996-07 to 2013-08-04 07:05:28.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-29 20:55:24.000002-07 to 2013-08-29 20:55:24.000002-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-08-29 20:25:25.999998-07 to 2013-08-29 20:25:25.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-08-30 02:25:25.999998 UTC to 2013-08-30 02:25:25.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2013-08-30 02:55:23.999992 UTC to 2013-08-30 02:55:23.999992 UTC flagged bad (prelim QC flag) 2014-11-14 10:21:07 oxygensat: 2013-09-29 20:05:01.000004-07 to 2013-09-29 20:05:01.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-30 07:35:02.000005-07 to 2013-09-30 07:35:02.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-17 12:35:20.999996-07 to 2013-09-17 12:35:20.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 07:35:17.999998-07 to 2013-09-21 07:35:17.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 07:15:19.000004-07 to 2013-09-21 07:15:19.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 07:55:19.999997-07 to 2013-09-21 08:25:18.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-09-21 16:55:17.999997-07 to 2013-09-21 16:55:17.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-09-30 07:35:02.000005-07 to 2013-09-30 07:35:02.000005-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 16:55:17.999997-07 to 2013-09-21 16:55:17.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 07:55:19.999997-07 to 2013-09-21 08:25:18.999995-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 07:35:17.999998-07 to 2013-09-21 07:35:17.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-21 07:15:19.000004-07 to 2013-09-21 07:15:19.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-17 12:35:20.999996-07 to 2013-09-17 12:35:20.999996-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-09-29 20:05:01.000004-07 to 2013-09-29 20:05:01.000004-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2014-11-14 10:21:07 oxygensat: 2013-10-04 11:25:01.999997-07 to 2013-10-04 12:15:07.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:07 oxygensat: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-14 10:21:06 oxygen: 2013-10-04 11:25:01.999997-07 to 2013-10-04 12:15:07.999997-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-14 10:21:06 oxygen: 2013-07-01 01:00:00-07 to 2013-10-05 01:00:00-07: type: 3 value: 21.0 comment: 7/1/13 - 10/5/13: The dissolved sensor deployed at 35m on the SATURN-02 buoy during 2013 was tested upon recovery where it read 97% in 100% aerated DI indicating that it was only slightly outside of manufacturer specifications. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-06-26 18:36:40.999994 UTC to 2014-06-26 19:46:32.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-06-27 11:27:00.000001 UTC to 2014-06-27 11:36:54.999992 UTC flagged bad (prelim QC flag) 2014-11-26 09:32:09 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:47 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-26 09:32:08 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:46 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2014-11-26 09:32:09 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:47 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2014-11-26 09:32:08 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:46 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2018-04-25 10:55:47 oxygensat: 2014-09-14 11:16:55.999998-07 to 2014-09-14 11:16:55.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-26 09:32:09 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:47 oxygensat: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2018-04-25 10:55:46 oxygen: 2014-09-14 11:16:55.999998-07 to 2014-09-14 11:16:55.999998-07: type: 1 value: 3.0 comment: Visually identified as outlier v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2014-11-26 09:32:08 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 3 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 8.6% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2018-04-25 10:55:46 oxygen: 2014-06-15 01:00:00-07 to 2014-10-01 01:00:00-07: type: 31 value: 2.0 comment: 6/15/14 10/1/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92% in 100% aerated DI. Following cleaning the sensor reading recovered to 99.8% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have applied a correction assuming linear drift from the point of deployment to the point of recovery. This correction should be considered approximate and data should be used with caution. v1: 1.0 v2: 1.087 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2016-04-21 10:37:01 oxygensat: 2015-05-24 16:12:57-07 to 2015-05-24 18:22:58.000002-07: type: 1 value: 3.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2016-04-21 10:37:00 oxygen: 2015-05-24 16:12:57-07 to 2015-05-24 18:22:58.000002-07: type: 1 value: 3.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-05-24 22:12:57 UTC to 2015-05-25 00:22:57.999992 UTC flagged bad (prelim QC flag) 2016-04-21 10:37:01 oxygensat: 2015-06-20 11:52:44.999999-07 to 2015-06-20 14:02:57.999997-07: type: 1 value: 3.0 comment: predeployment tail of data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) 2016-04-21 10:37:00 oxygen: 2015-06-20 11:52:44.999999-07 to 2015-06-20 14:02:57.999997-07: type: 1 value: 3.0 comment: predeployment tail of data v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-20 17:52:44.999999 UTC to 2015-06-20 20:02:57.999997 UTC flagged bad (prelim QC flag) 2016-04-21 10:37:01 oxygensat: 2015-07-23 21:13:08.999999-07 to 2015-07-23 21:13:08.999999-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-07-24 10:23:09-07 to 2015-07-24 10:23:09-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2016-04-21 10:37:00 oxygen: 2015-07-23 21:13:08.999999-07 to 2015-07-23 21:13:08.999999-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-07-24 10:23:09-07 to 2015-07-24 10:23:09-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad 2016-04-21 10:37:01 oxygensat: 2015-08-19 17:03:08.000003-07 to 2015-08-19 17:13:07.999997-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-08-18 19:33:08-07 to 2015-08-18 19:33:08-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-08-18 20:33:07.999996-07 to 2015-08-18 21:53:08.000002-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:01 oxygensat: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 180.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad 2016-04-21 10:37:00 oxygen: 2015-08-18 19:33:08-07 to 2015-08-18 19:33:08-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-08-18 20:33:07.999996-07 to 2015-08-18 21:53:08.000002-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-08-19 17:03:08.000003-07 to 2015-08-19 17:13:07.999997-07: type: 1 value: 23.0 comment: data pattern suspect v1: -9999.0 v2: -9999.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 2016-04-21 10:37:00 oxygen: 2015-05-24 01:00:00-07 to 2015-10-25 01:00:00-07: type: 3 value: 2.0 comment: 5/24/15 10/10/14: The calibration was checked in 100% aerated DI prior to deployment and was reading within manufacturer specifications. The post deployment check showed that the sensor was reading 92.7% in 100% aerated DI. Following cleaning the sensor reading recovered to 100% indicating that the drift was due to sensor fouling. Because we lack supporting information on the nature of the calibration drift (gradual fouling over time, vs. a single fouling event), we have not applied any correction to the data from this deployment. Data may be up to 7% low, especially toward the end of deployment and data should be used with caution. v1: 1.0 v2: 0.0 v3: 0.0 v4:10000.0 reference_var: N version: 0 Data greater than maximum valid value 12.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 17:54:20.999991 UTC to 2016-10-10 17:54:30.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 17:54:20.999991 UTC to 2016-10-10 17:54:30.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-07-04 06:26:04.999994 UTC to 2017-07-04 06:26:04.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-07-04 06:26:04.999994 UTC to 2017-07-04 06:26:04.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2018-10-13 01:34:24.999994 UTC to 2018-10-13 01:34:24.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-10-16 02:08:24.999993 UTC to 2018-10-16 02:08:24.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2018-10-13 01:34:24.999994 UTC to 2018-10-13 01:34:24.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2018-10-16 02:08:24.999993 UTC to 2018-10-16 02:08:24.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-19 15:45:08.999995 UTC to 2019-05-19 15:45:08.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-10-31 18:44:08.999998 UTC to 2019-10-31 18:44:08.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-02 18:16:49.999997 UTC to 2021-08-02 18:18:50 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-21 09:53:49.999995 UTC to 2021-08-21 09:53:49.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-17 06:06:49.999992 UTC to 2021-09-17 06:10:49.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-02 18:16:49.999997 UTC to 2021-08-02 18:18:50 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-21 09:53:49.999995 UTC to 2021-08-21 09:53:49.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-17 06:06:49.999992 UTC to 2021-09-17 06:10:49.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2023-01-23 17:59:19.999992 UTC to 2023-01-23 17:59:29.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2023-01-23 17:59:19.999992 UTC to 2023-01-23 17:59:29.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-06-10 08:00:00 UTC to 2016-06-20 08:00:00 UTC flagged bad (spikes of bad data) Data with values less than 15.0, during the time period from 2016-06-30 20:00:00 UTC to 2016-06-30 21:00:00 UTC flagged bad (spike of bad data at restart of data flow) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-07-06 18:15:00 UTC to 2016-07-06 18:50:00 UTC flagged bad (spike of bad data across all depths) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 10.0, during the time period from 2018-07-02 11:20:20 UTC to 2018-07-02 21:20:21 UTC flagged bad (outlier identified by visual inspection) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2018-10-25 20:00:00 UTC to 2018-11-01 08:00:00 UTC flagged bad (post-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2009-11-22 00:27:43.999993 UTC to 2009-11-22 00:27:53.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2010-08-27 02:23:02.999999 UTC to 2010-08-27 02:23:02.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:30.999995 UTC to 2011-07-01 19:01:32.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 06:37:30.999995 UTC to 2011-07-01 19:01:32.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-04 23:59:40.999996 UTC to 2011-07-04 23:59:40.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-10 06:23:54 UTC to 2011-07-10 06:23:54 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-14 12:40:04 UTC to 2011-07-14 12:40:04 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-07-14 12:46:03.999998 UTC to 2011-07-14 12:46:03.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data with values less than False, during the time period from 2011-07-01 07:00:00 UTC to 2011-07-01 19:45:00 UTC flagged bad (Buoy reporting but not yet deployed) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-08-02 21:40:50.999996 UTC to 2011-08-02 21:40:50.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-08-10 16:35:08.999997 UTC to 2011-08-10 16:35:08.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2011-04-15 08:09:36.000001 UTC to 2011-04-15 08:09:36.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-04-15 09:09:35.999997 UTC to 2011-04-15 09:09:35.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2011-04-22 11:05:41.999992 UTC to 2011-04-22 11:05:41.999992 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-20 19:17:15.999993 UTC to 2012-10-20 19:17:25.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:24.999997 UTC to 2012-04-25 00:05:14 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-10-20 19:17:15.999993 UTC to 2012-10-20 19:17:25.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-24 00:37:24.999997 UTC to 2012-04-25 00:05:14 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data with values less than False, during the time period from 2012-04-23 07:00:00 UTC to 2012-04-24 07:00:00 UTC flagged bad (pre-deployment tail) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-07-15 00:23:22.999998 UTC to 2013-07-16 17:44:24.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2013-10-04 13:21:27.999994 UTC to 2013-10-04 16:47:28.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2014-06-22 06:01:09.999996 UTC to 2014-06-26 20:31:04.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2014-06-22 06:01:09.999996 UTC to 2014-06-26 20:31:04.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-05-24 22:10:04.999997 UTC to 2015-05-24 23:46:19.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-05-31 13:58:19.000001 UTC to 2015-05-31 13:58:19.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-20 18:51:19.999994 UTC to 2015-06-20 20:27:24.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-06-24 12:49:24.999994 UTC to 2015-06-24 12:49:24.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-06-25 19:01:27.000001 UTC to 2015-06-25 19:01:27.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data with values less than False, during the time period from 2015-06-18 19:00:00 UTC to 2015-06-20 21:33:00 UTC flagged bad (predeployment tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-07-18 19:10:00.999999 UTC to 2015-07-18 19:10:00.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-07-19 06:13:59.999994 UTC to 2015-07-19 06:13:59.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-07-21 00:29:59.999997 UTC to 2015-07-21 00:29:59.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-07-21 04:03:59.999996 UTC to 2015-07-21 04:03:59.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-07-26 11:46:08 UTC to 2015-07-26 11:46:08 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2015-08-04 21:04:20.000001 UTC to 2015-08-04 21:04:20.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-07 10:34:24 UTC to 2015-08-07 10:34:24 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-07 11:14:23.999997 UTC to 2015-08-07 11:14:23.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-12 18:52:31.000001 UTC to 2015-08-12 18:52:31.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-22 13:16:43.999996 UTC to 2015-08-22 13:16:43.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-22 23:50:44.999996 UTC to 2015-08-22 23:50:44.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2015-08-27 14:44:50.999995 UTC to 2015-08-27 14:44:50.999995 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-17 02:24:45.999993 UTC to 2016-06-17 02:24:45.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-17 10:24:45.999997 UTC to 2016-07-17 10:24:45.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-08-06 19:19:45.999994 UTC to 2016-08-06 19:19:45.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-09-13 14:24:45.999993 UTC to 2016-09-13 14:24:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-09-30 16:49:45.999998 UTC to 2016-09-30 16:49:45.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-06-17 02:24:45.999993 UTC to 2016-06-17 02:24:45.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-07-17 10:24:45.999997 UTC to 2016-07-17 10:24:45.999997 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-08-06 19:19:45.999994 UTC to 2016-08-06 19:19:45.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-09-13 14:24:45.999993 UTC to 2016-09-13 14:24:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-09-30 16:49:45.999998 UTC to 2016-09-30 16:49:45.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-05-26 20:21:58.999994 UTC to 2017-05-26 20:21:58.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-05-31 21:35:59.000001 UTC to 2017-05-31 21:35:59.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-06-04 03:29:58.999992 UTC to 2017-06-04 03:29:58.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-10 21:09:58.999993 UTC to 2017-06-10 21:09:58.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-11 02:03:58.999998 UTC to 2017-06-11 02:03:58.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-11 04:45:58.999992 UTC to 2017-06-11 04:45:58.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-14 10:29:58.999999 UTC to 2017-06-14 10:29:58.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-19 00:01:59.000002 UTC to 2017-06-19 00:01:59.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-24 18:43:58.999992 UTC to 2017-06-24 18:43:58.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2017-06-27 20:53:59 UTC to 2017-06-27 20:53:59 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-07-09 14:09:58.999996 UTC to 2017-07-09 14:09:58.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-02 17:43:02.999998 UTC to 2019-05-16 16:45:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-25 01:09:01.999997 UTC to 2019-05-25 01:09:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-25 16:29:01.999996 UTC to 2019-05-25 16:29:01.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-06-24 04:49:01.999995 UTC to 2019-06-24 04:53:02.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-15 14:47:01.999999 UTC to 2019-07-15 14:47:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-15 20:39:01.999997 UTC to 2019-07-15 20:39:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-16 20:39:01.999997 UTC to 2019-07-16 20:39:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-16 20:43:01.999993 UTC to 2019-07-16 20:43:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-27 21:59:01.999993 UTC to 2019-07-27 21:59:01.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-05-02 17:43:02.999998 UTC to 2019-05-16 16:45:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-25 01:09:01.999997 UTC to 2019-05-25 01:09:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-05-25 16:29:01.999996 UTC to 2019-05-25 16:29:01.999996 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-06-24 04:49:01.999995 UTC to 2019-06-24 04:53:02.000001 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-07-15 14:47:01.999999 UTC to 2019-07-15 14:47:01.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-15 20:39:01.999997 UTC to 2019-07-15 20:39:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-16 20:39:01.999997 UTC to 2019-07-16 20:39:01.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-16 20:43:01.999993 UTC to 2019-07-16 20:43:01.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2019-07-27 21:59:01.999993 UTC to 2019-07-27 21:59:01.999993 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-04 18:50:33.999992 UTC to 2021-08-04 18:50:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-04 20:23:34.000002 UTC to 2021-08-04 20:23:34.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 22:04:33.999992 UTC to 2021-08-05 22:05:33.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 12:43:33.999997 UTC to 2021-08-06 12:43:33.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 23:54:34.000001 UTC to 2021-08-06 23:54:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 23:59:33.999994 UTC to 2021-08-07 00:00:34 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-07 17:58:33.999997 UTC to 2021-08-07 17:58:33.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-12 22:03:33.999996 UTC to 2021-08-12 22:03:33.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 07:56:33.999998 UTC to 2021-08-15 07:56:33.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 08:04:33.999999 UTC to 2021-08-15 08:04:33.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 10:46:33.999993 UTC to 2021-08-15 10:46:33.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 12:36:33.999992 UTC to 2021-08-15 12:36:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 13:51:33.999995 UTC to 2021-08-15 13:51:33.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 14:25:33.999994 UTC to 2021-08-15 14:25:33.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 14:55:33.999998 UTC to 2021-08-16 14:55:33.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 15:08:34.000002 UTC to 2021-08-16 15:08:34.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 23:54:34.000001 UTC to 2021-08-16 23:54:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 23:57:34.000001 UTC to 2021-08-16 23:57:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 00:00:34 UTC to 2021-08-17 00:00:34 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 11:54:34.000001 UTC to 2021-08-17 11:54:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 14:24:33.999998 UTC to 2021-08-17 14:24:33.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 14:27:33.999997 UTC to 2021-08-17 14:27:33.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 14:31:33.999993 UTC to 2021-08-17 14:31:33.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-18 03:50:33.999992 UTC to 2021-08-18 03:50:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-18 16:27:34.000001 UTC to 2021-08-18 16:27:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-19 19:40:33.999994 UTC to 2021-08-19 19:40:33.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-21 17:47:33.999996 UTC to 2021-08-21 17:47:33.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-21 18:42:34.000001 UTC to 2021-08-21 18:42:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-23 11:06:33.999992 UTC to 2021-08-23 11:06:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-23 11:34:33.999992 UTC to 2021-08-23 11:34:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-29 15:17:34 UTC to 2021-08-29 15:17:34 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-12 20:59:33.999994 UTC to 2021-09-12 20:59:33.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-08-04 18:50:33.999992 UTC to 2021-08-04 18:50:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-04 20:23:34.000002 UTC to 2021-08-04 20:23:34.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-05 22:04:33.999992 UTC to 2021-08-05 22:05:33.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 12:43:33.999997 UTC to 2021-08-06 12:43:33.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 23:54:34.000001 UTC to 2021-08-06 23:54:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-06 23:59:33.999994 UTC to 2021-08-07 00:00:34 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-07 17:58:33.999997 UTC to 2021-08-07 17:58:33.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-12 22:03:33.999996 UTC to 2021-08-12 22:03:33.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 07:56:33.999998 UTC to 2021-08-15 07:56:33.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 08:04:33.999999 UTC to 2021-08-15 08:04:33.999999 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 10:46:33.999993 UTC to 2021-08-15 10:46:33.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 12:36:33.999992 UTC to 2021-08-15 12:36:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 13:51:33.999995 UTC to 2021-08-15 13:51:33.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-15 14:25:33.999994 UTC to 2021-08-15 14:25:33.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 14:55:33.999998 UTC to 2021-08-16 14:55:33.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 15:08:34.000002 UTC to 2021-08-16 15:08:34.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 23:54:34.000001 UTC to 2021-08-16 23:54:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-16 23:57:34.000001 UTC to 2021-08-16 23:57:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 00:00:34 UTC to 2021-08-17 00:00:34 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 11:54:34.000001 UTC to 2021-08-17 11:54:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 14:24:33.999998 UTC to 2021-08-17 14:24:33.999998 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 14:27:33.999997 UTC to 2021-08-17 14:27:33.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-17 14:31:33.999993 UTC to 2021-08-17 14:31:33.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-18 03:50:33.999992 UTC to 2021-08-18 03:50:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-18 16:27:34.000001 UTC to 2021-08-18 16:27:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-19 19:40:33.999994 UTC to 2021-08-19 19:40:33.999994 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-21 17:47:33.999996 UTC to 2021-08-21 17:47:33.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-21 18:42:34.000001 UTC to 2021-08-21 18:42:34.000001 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-23 11:06:33.999992 UTC to 2021-08-23 11:06:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-23 11:34:33.999992 UTC to 2021-08-23 11:34:33.999992 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2021-08-29 15:17:34 UTC to 2021-08-29 15:17:34 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2021-09-12 20:59:33.999994 UTC to 2021-09-12 20:59:33.999994 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-05-21 05:41:45.999993 UTC to 2022-05-21 05:41:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-24 04:30:45.999995 UTC to 2022-05-24 04:30:45.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-27 22:37:46 UTC to 2022-05-27 22:37:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-30 05:06:45.999997 UTC to 2022-05-30 05:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-30 18:33:45.999998 UTC to 2022-05-30 18:33:45.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-09 01:20:46.000001 UTC to 2022-06-09 01:21:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-15 19:27:45.999996 UTC to 2022-06-15 19:27:45.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-19 14:47:46.000002 UTC to 2022-06-19 14:47:46.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-23 04:10:40.999993 UTC to 2022-06-23 04:10:50.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-09 12:16:45.999998 UTC to 2022-07-09 12:16:45.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-05-21 05:41:45.999993 UTC to 2022-05-21 05:41:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-24 04:30:45.999995 UTC to 2022-05-24 04:30:45.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-27 22:37:46 UTC to 2022-05-27 22:37:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-30 05:06:45.999997 UTC to 2022-05-30 05:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-30 18:33:45.999998 UTC to 2022-05-30 18:33:45.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-09 01:20:46.000001 UTC to 2022-06-09 01:21:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-15 19:27:45.999996 UTC to 2022-06-15 19:27:45.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-19 14:47:46.000002 UTC to 2022-06-19 14:47:46.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-23 04:10:40.999993 UTC to 2022-06-23 04:10:50.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-09 12:16:45.999998 UTC to 2022-07-09 12:16:45.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-05-21 05:41:45.999993 UTC to 2022-05-21 05:41:45.999993 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-24 04:30:45.999995 UTC to 2022-05-24 04:30:45.999995 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-27 22:37:46 UTC to 2022-05-27 22:37:46 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-30 05:06:45.999997 UTC to 2022-05-30 05:06:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-05-30 18:33:45.999998 UTC to 2022-05-30 18:33:45.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-06-09 01:20:46.000001 UTC to 2022-06-09 01:21:45.999997 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-15 19:27:45.999996 UTC to 2022-06-15 19:27:45.999996 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-19 14:47:46.000002 UTC to 2022-06-19 14:47:46.000002 UTC flagged bad (prelim QC flag) Data with values less than False, during the time period from 2022-06-23 04:10:40.999993 UTC to 2022-06-23 04:10:50.999999 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2022-07-09 12:16:45.999998 UTC to 2022-07-09 12:16:45.999998 UTC flagged bad (prelim QC flag) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 15.0, during the time period from 2016-07-06 18:15:00 UTC to 2016-07-06 18:50:00 UTC flagged bad (spike of bad data across all depths) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data with values less than False, during the time period from 2016-10-10 20:45:00 UTC to 2016-10-13 20:45:00 UTC flagged bad (data from after station was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data with values less than False, during the time period from 2017-10-30 20:25:00 UTC to 2017-11-01 08:00:00 UTC flagged bad (data from after mooring was recovered) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than 10.0, during the time period from 2018-07-02 11:46:00 UTC to 2018-07-02 11:46:00 UTC flagged bad (outlier identified by visual inspection) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 35.0 preliminarily flagged bad Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data with values less than False, during the time period from 2019-11-08 17:26:00 UTC to 2019-12-01 08:00:00 UTC flagged bad (post-recovery tail of data) Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad Data greater than maximum valid value 28.0 preliminarily flagged bad Data greater than maximum valid value 35.0 preliminarily flagged bad |
| attribute | chlorophyll_qc | standard_name | String | mass_concentration_of_chlorophyll_in_sea_water status_flag |
| attribute | chlorophyll_qc | valid_max | byte | 9 |
| attribute | chlorophyll_qc | valid_min | byte | 0 |
| variable | raw_chlorophyll | double | ||
| attribute | raw_chlorophyll | _FillValue | double | 9.969209968386869E36 |
| attribute | raw_chlorophyll | actual_range | double | 0.0, 38.21 |
| attribute | raw_chlorophyll | ancillary_variables | String | platform instrument chlorophyll_qc chlorophyll |
| attribute | raw_chlorophyll | colorBarMaximum | double | 150.0 |
| attribute | raw_chlorophyll | colorBarMinimum | double | 0.0 |
| attribute | raw_chlorophyll | coverage_content_type | String | physicalMeasurement |
| attribute | raw_chlorophyll | instrument | String | instrument |
| attribute | raw_chlorophyll | ioos_category | String | Quality |
| attribute | raw_chlorophyll | long_name | String | Raw and uncorrected Chlorophyll fluorescence prior to qc processing that adjusted data values |
| attribute | raw_chlorophyll | platform | String | platform |
| attribute | raw_chlorophyll | source | String | measurement reported by the instrument |
| attribute | raw_chlorophyll | standard_name | String | mass_concentration_of_chlorophyll_in_sea_water |
| attribute | raw_chlorophyll | units | String | microg/l |
| attribute | raw_chlorophyll | varname | String | chlorophyll |
The information in the table above is also available in other file formats (.csv, .htmlTable, .itx, .json, .jsonlCSV1, .jsonlCSV, .jsonlKVP, .mat, .nc, .nccsv, .tsv, .xhtml) via a RESTful web service.